SE620 Installation & Operation Instructions
|
|
- Lee Douglas
- 5 years ago
- Views:
Transcription
1 SE620 Installation & Operation Instructions Installation Step 1: Install enclosure coupling and enclosure bracket Using a 5/32 allen wrench remove the 2 screws attaching the enclosure bracket(1) to the enclosure coupling(2). Take note of how it is installed. Apply thread sealant to and install the enclosure coupling in the process ball valve. Using the same 5/32 allen wrench and screws, re-install the enclosure bracket onto the enclosure coupling, in the fashion noted above. Step 2: Install the 750 probe regulator Follow the provided 750 instructions to install the probe into the female threads of the enclosure coupling. Insert it to its full insertion depth. Connect the probe outlet tube fitting(3) to the tube coil. Step 3: Connect the sample tubing Run the sample tube through the heat shrink entry boot(4) Terminate the heat trace (if applicable) Connect the sample tubing from the analyzer to the sample outlet(5). Step 4: Connect power to the enclosure Run VAC power to the inlet of the junction box(6) via the method required by your hazardous area classification. NOTE: A conduit seal fitting may be required. Open the junction box and connect wires. Follow the provided Intertec instructions for wiring. Turn power on to the enclosure Step 5: Set the outlet pressure of the GHR regulator CAUTION: The GHR will be HOT Follow the provided GHR instructions for setting the regulator. Step 6: Install enclosure around assembly Slide either enclosure half onto the enclosure bracket bulkhead boots, hold it in place with attached quick release pin(7). Repeat the above step with the remaining enclosure half. Latch the two half of the enclosure together via the enclosure latches(8) A+ Corporation, LLC. All rights reserved. SE620-InsInstallationOperation_0717
2 Genie Direct Drive 750 Adapter Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: Black Bayou Rd. Gonzales, LA Phone: (225) Website: Fax: (225) Safety Warnings Failure to abide by any of the safety warnings below may result in equipment failure or serious injury and death. Do not exceed any equipment pressure ratings The probe must be installed to the process line by means of the appropriate size NPT female full port ball valve Only the lowest wrench flats on the base, nearest to the NPT male threads, can be used when installing into the process ball valve DO NOT use the wrench flats on the packing adjustment nut, located on the top of the base, for installation into process ball valve. Not designed for external fire. Prior to use in a system, a properly sized relief device is to be installed which limits the use to 110% of the MAWP. Tools Required 1-3/8 open end wrench 7/16 open end wrench (2) 7/8 open end wrenches 1-3/16 open end wrench Tools Required Flat blade screwdriver Fittings Required Appropriate size female full port ball valve An ISO 9001:2008 certified company 2010 A+ Corporation, LLC. All rights reserved. SCC-750-A-InsInstallationOperation_0116
3 Technical Specifications Technical Specifications Maximum pressure rating Temperature ranges (for other temperatures, contact the factory) Port sizes Probe lengths (for other lengths contact the factory) Process connection requirements Wetted materials (for exotic materials of construction or Silcotek coatings, contact the factory) NPT: 3,750 psig (258 Bar) Unibody flanged: Dependent upon flange ANSI classification Up to 300 F (148.9 C) with non-standard seals and hi-flow backed membrane -35 F (-37.2 C) to 185 F (85 C) with Type 6/BTU membrane Standard Outlet: 1/8 female NPT with factory installed adapter Hex Adapter: 1/4 female NPT outlet with integrated outlet shut-off valve Composite Sample Adapter: ¾ female NPT outlet Auxiliary: 1/8 female NPT (plugged from factory) L: 8, 12, 18, 24, 36, 48 A: ~ 16, 20, 26, 32, 44, 56 (refer to L & A dimensions on back) 3/4", 1, or 1.5 NPT full opening threaded *Ball, gate, and double block and bleed valves are all suitable for use as long as their inner diameter is not less than ¾. 1 NPT or larger process connection required for seal welding. Machined parts: 316/316L stainless steel /NACE compliant and Kevlar threaded bushing All other metal parts: stainless steel / NACE compliant Sealing material: PTFE/Neoprene rubber standard Membrane: Inert An ISO 9001:2008 certified company A+ Corporation, LLC. All rights reserved. SCC-750-A-InsInstallationOperation_0116
4 Installation Instructions Step 1. Insure the valve is closed The valve at the top of the probe must remain closed until the duration of installation. Ensure it is closed by using a flat blade screwdriver to turn the integrated outlet valve in the clockwise direction, until it is snug. Step 2. Install to process valve Be sure the ball valve to the process line is closed Apply a thread sealant, such as Teflon Tape, to the male threads on the bottom of the probe Install the probe to the process ball valve using a 1-3/8 open end wrench ONLY on the lowest wrench flats on the base, nearest to the NPT male threads (see Figure 1) Step 3. Pressurize the probe Be sure the valve on top of the probe is closed Slowly open the ball valve to the process (see Figure 2) Step 4. Lowering the probe to proper depth Decide the depth needed for the probe (D1) by determining from the top of the full port process ball valve to the desired end of the probe in the pipeline (see Figure 4) Apply the depth (D1) to the probe from the top of the base up the threaded rod to determine the lowering stopping point (see Figure 3) Install the 2 depth marking nuts on the threaded rod at the predetermined lower stopping point. Using two 7/8 open end wrenches, rotate the upper nut clockwise and the lower nut counterclockwise simultaneously until the nuts are locked firmly in place. Lower the probe to the proper depth by using a 7/16 open end wrench only on the wrench flats of the threaded rod of the probe (Figure 5). Step 5. Leak testing the probe connections Using a leak detector, check for leaks at the following locations: process connection, probe packing seal, the 1/4 connection to the top valve adapter, and additionally any other connection made during the probe installation. If leaking occurs through the probe packing gland, use a 1 3/16 open end wrench to tighten the packing seal plug until the leak stops. DO NOT OVERTIGHTEN. Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 D1 D1 An ISO 9001:2008 certified company A+ Corporation, LLC. All rights reserved. SCC-750-A-InsInstallationOperation_0116
5 PRODUCT MANUAL: GHR-CSA Overview Before You Start Regulator Installation Maintenance Model Numbering Product Dimensions Support Documents geniefilters.com Analyzer Sampling Solutions > Moisture & Corrosion Control > Knowledgeware A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
6 PAGE 2 OVERVIEW PRODUCT MANUAL Introduction This manual is intended to be used as a basic installation, operation, and maintenance guide for the Genie Model GHR Heated Regulator and has been carefully checked for accuracy. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the warranty. If you receive a damaged product, please contact your distributor immediately. Installation of this product is of a mechanical and electrical nature. The installer and operator should understand how to use tube fittings, make electrical connections, and be trained in installing this type of equipment and in protection practices required to maintain the area classification of the electrical equipment in hazardous locations. Product Description The Model GHR is a single stage heated pressure regulator designed specifically for use in gas analytical systems. The GHR prevents condensation of the sample gas from occurring as a result of the pressure reduction process of high pressure and high dew point gases or due to low operating or ambient temperature conditions. The GHR is heated with a self-limiting block heater, a simple and reliable heating option that prevents temperature overload and is easily mounted in small enclosures or densely-populated cabinets. Technical Specifications The specifications listed in this section are generalized for this product. Please note that specifications may vary depending on the customizations of your equipment. Technical Specifications Maximum pressure rating Outlet pressure range Temperature range Port sizes Cv Coefficient Maximum flow rate Wetted materials Electrical connection Power requirements Electrical approval 6000 PSIG (414 barg) per criteria of ANSI/ASME B psig (0-0.7 barg), 0-25 psig (0-1.7 barg), 0-50 psig (0-3.4 barg), psig (0-6.9 barg), psig ( barg), psig (34.5 barg) Ambient: GHR (CSA): -40 to 302 F (-40 to 150 C) 901-GR: 0 to 145 F (-18 to 63 C) GHR (ATEX): -40 to 140 F (-40 to 60 C) Process (all models): -15 to 300 F (-26 to 149 C) - standard seals -40 to 300 F (-40 to 149 C) - low temperature seals 901-GR controller: 95 to 300 F (35 to 149 C) set at 300 F; backup thermal cutoff opens at 338 F 1/4 female NPT 0.06 ~10 SLM (consider heat transfer limitations) Machined parts: 316/316L stainless steel / NACE compliant All other metal parts: stainless steel / NACE compliant Regulator seat material: PFA Seals: Fluoroelastomer Conduit (CSA): GHR: 1/2 female NPT 901-GR: 3/4 female NPT Cable OD (ATEX/IECEx): 3/8 (10mm) GHR: VAC, 80W or VDC, 25W 901-GR: VAC or VAC CSA Certified Assembly: File # ; Class 1, Division 1, Groups B, C, & D; T3 ATEX/IECEx Heater Block (Model GHR only): Zone 1, II 2G, Ex d, IIC, T3, Gb BEFORE YOU START Safety Warnings The images below will be used to alert you to various types of safety messages. Obey all safety messages that follow this symbol to avoid possible injury/death or equipment damage. WARNING messages will appear before procedures that could result in serious personal injury or death. CAUTION messages will appear before procedures that could result in minor or moderate injury. NOTICE messages will appear before procedures that could result in damage to equipment. A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 geniefilters.com Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
7 PAGE 3 Read this manual completely and carefully before installing or using this product. Failure to do so can result in serious injury or death. Save these instructions for future reference and for the local inspector s use. Observe all governing codes and ordinances. General Improper selection/installation/maintenance, misuse, or abuse of this equipment can cause death, serious injury, and property damage. Do not exceed ANY equipment pressure ratings. Refer to the technical specifications table for maximum pressure rating of the system. Verify the designed pressure ratings of all equipment in your system (supply lines, fittings, connections, filters, valves, gauges, etc.). Prior to use in a system, a properly-sized relief device is to be installed, which limits the use to 110% of the MAWP. Some fluids, when burning, do not exhibit a visible flame. Use extreme caution when inspecting and/or servicing systems using flammable fluids to avoid death or serious injury to personnel. Provide a device to warn personnel of these dangerous conditions. Not designed for external fire or for use with mixtures of an explosive gas and air/oxygen. Surface temperatures can approach the temperature limit stated in technical specifications. Gloves may be required for handling and adjustment. Do not use the regulator as a shut-off device. A ball valve on the outlet is recommended for this purpose. Our Genie Regulator Accessory Manifold is designed to thread directly into any Genie ProbeRegulator or Genie Regulator and provides a means to monitor regulator outlet pressure and block flow. Electrical Electrical power must be OFF before and during installation and maintenance or personal injury may result. All appropriate national, state, and electrical codes must be followed. The power supply is with the help of a silicone cable, notch, and oil resistant. The cable is intended for installation inside a rigid metal conduit, cable tray, or a similar method which provides sufficient mechanical strength to the cable against stress and bending. Grounding to be provided at the final location of installation. INSTALLATION AND OPERATION Installation and Operation Notes The regulator should be installed in a KOZY insulated jacket, ACES enclosure, or similar type of insulating device. Refer to the Temperature Limitations section of the enclosed INTERTEC document from information concerning the heat transfer coefficient of the enclosure surrounding the regulator. Our KOZY insulated jacket and INTERTEC enclosures used in our ACES systems meet this requirement. Bracket mounting is optional, but is suggested as mounting makes it stationary for quick and easy operation. Valve off sample flow prior to regular installation. Required Tools and Materials Gloves (4) 1/4 screws and insulating washers Screwdriver 3/8 allen wrench for setting outlet pressure Crescent wrench for general purpose A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 geniefilters.com Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
8 PAGE Mount 1. The regulator can be mounted in any position, preferably with the block heater at the bottom so heat can rise into the body of the regulator. 2. Use of insulating washers between the regulator and the enclosure/panel is required to maximize block heater efficiency. Position the (4) insulating washers over the holes that have been drilled for mounting. 3. Place the regulator over the insulating washers with bracket holes aligned over the washers holes. 4. Affix the regulator to the enclosure/panel by inserting (4) 1/4 screws into the mounting bracket holes and tighten with a screwdriver. Connect tubing 1. Connect tubing from the sample stream to the inlet port. 2. Connect tubing from the outlet port to the next device in the sample system. 3. The GHR is a non-venting regulator. The port that is not labeled is an atmospheric reference port for the regulator. If threaded, tubing can be connected to permit venting of hazardous process gases to a safe area through a vent line in the event of a seal failure. NOTICE: DO NOT plug the atmospheric vent port or the regulator s performance will be affected. Connect power 1. Verify that the block heater voltage matches the voltage of the available power supply. 2. Refer to the INTERTEC literature provided with the unit for electrical wiring. Power up 1. Turn power on. 2. Allow at least 10 minutes for the block heater to warm before moving on to the next step. Atmospheric reference DO NOT PLUG Block Heater Voltage ID label Wire ID label 5. Establish flow and adjust pressure CAUTION: The regulator will be HOT. Perform the following steps with gloves on to avoid burns. 1. Slowly open external valving to avoid a sudden surge in fluid or pressure. Pressure adjustment screw Locking nut 2. Use a 3/8 allen wrench to turn the allen cap pressure adjustment screw located on top of the regulator to adjust pressure while gas is flowing through the regulator. To raise the outlet pressure, turn the screw clockwise. To lower the outlet pressure, turn the screw counterclockwise. 3. Monitor outlet pressure and flow for the next 30 minutes or until both stabilize. The pressure adjustment set point may have to be adjusted once the temperature is stabilized. 4. Once pressure and flow are stable, use a crescent wrench to firmly tighten the locking nut around the pressure adjustment screw to prevent unintended changes in pressure adjustment. NOTICE: At high supply pressure, a sudden change may be observed on the downstream pressure gauge as the valve stem moves away from the seat. Slight readjustments may be necessary until the pressure and flow have equilibrated. A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 geniefilters.com Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
9 PAGE 5 MAINTENANCE Maintenance Notes Periodic inspection of your equipment is required for continued safe operation (at least once per year). Perform visual, electrical, and mechanical checks on all components on a regular basis. Visually inspect for undue heating evidenced by discoloration of wires or other components, damaged or worn parts, or leakage evidence by water or corrosion in the interior. Visually inspect to make sure that all electrical connections are clean and tight and that the device is operating properly. Although there are no routine maintenance items for the regulator, repair kits are offered for inlet filter, heater block, and seat & seal (if the regulator contains non-standard seals, the seal material type will be etched on the body under the A+ logo.) Please contact the factory or your local distributor for part numbers and pricing, or for the evaluation of any failures or other needed repairs. Review the Safety Warnings in the BEFORE YOU START section of the manual before performing any maintenance. WARNING: To avoid personal injury, property damage or equipment damage caused by a sudden release of pressure, or explosion of accumulated gas, do not attempt any maintenance or disassembly without first isolating the regulator from system pressure and relieving all internal pressure from the regulator. To avoid personal injury, electrical power must be turned off and locked out prior to attempting any maintenance or disaasembly. Heater Block Replacement Required Tools and Materials 1/8 allen wrench 5/16 wrench or nut driver for bracket removal Gloves 1. Remove heater CAUTION: The regulator may be HOT. Allow approximately thirty (30) minutes for the heater to cool prior to performing maintenance and use gloves to avoid burns. 1. Remove the fasteners (nuts, washers, and spacers) that are holding the heater block in place. DO NOT discard the fasteners. 2. Remove the heater from the regulator. Fasteners 2. Install new heater 1. Place the new heater in the bracket with its cord on the same side as the inlet port. 2. Use the original fasteners to attach the heater to the bracket. 3. Refer to steps 4 & 5 on PAGE 4 on powering up, establishing flow, and setting pressure. Inlet Cord Spacer Flat washer Lock washer Nut Spacer Flat washer Lock washer Nut A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 geniefilters.com Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
10 PAGE 6 Inlet Filter Replacement Required Tools and Materials Retaining ring pliers Gloves 1. Remove old parts CAUTION: The regulator may be HOT. Allow approximately thirty (30) minutes for the heater to cool prior to performing maintenance and use gloves to avoid burns. 1. Use retaining ring pliers to remove and discard the retaining ring from the inlet port. 2. Remove and discard the filter disc and gasket located behind the retaining ring. 3. Remove and clean the heat transfer rod (dowel pin and spring). Inlet port Clean Discard 2. Install new parts 1. Install the heat transfer rod (dowel and spring), new gasket, and new filter into the inlet port. 2. Use retaining ring pliers to install the retaining ring into the inlet port. 3. Refer to steps 4 & 5 on PAGE 4 on powering up, establishing flow, and setting pressure. Inlet port Use retaining ring pliers to install. Seat & Seal Replacement Required Tools and Materials Spanner bit (included with kit) In/lbs torque wrench/screwdriver Ft/lb torque wrench Krytox GPL 206 lubricant Loctite 243 thread adhensive 1.5 open end wrench or crow s foot Needle-nose pliers 1/4 hex socket adapter Acetone or similar solvent Vice Gloves 1. Remove heater block CAUTION: The regulator may be HOT. Allow approximately thirty (30) minutes for the heater to cool prior to performing maintenance and use gloves to avoid burns. 1. Refer to PAGE 5 for instructions on removing the heater block from the regulator. A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 geniefilters.com Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
11 PAGE 7 2. Discard Separate the two halves 1. Clamp the regulator in a vice using the wrench flats near the bottom half of the regulator body. 2. Remove the bolt, nut, washer, and o-ring from the top of the regulator. Discard ONLY the o-ring. the o-ring Set the rest aside 3. Use a 1.5 open end wrench or crow s foot to loosen the top by rotating it counterclockwise. DO NOT unscrew all of the way or the parts in the top will fall out. 4. Remove the regulator from the vice and turn it upside-down. 5. Separate the two halves and place the top upside-down on a clean work space. 3. Replace o-ring in bottom half 1. Remove the o-ring on top of the regulator bottom and the white Teflon spacer underneath it. Replace with new o-ring 2. Clean the threads with a solvent (acetone or similar) to remove any liquids, oils, or grease from the threads. 3. Install the new #2-026 o-ring and Teflon spacer from the kit. 4. Lightly lube the o-ring with Krytox. 4. Remove parts from bottom 1. Use the spanner bit or 1/4 hex socket screwdriver to remove the seat retention nut. Use the spanner bit Seat retention nut 2. Gently grab the end of the stem and pull out with needle-nose pliers. 3. Discard the o-ring, stem, and seat. DO NOT discard the seat retention nut. Discard the components 5. Replace parts in bottom 1. Place a new seat on the small end of the new stem. Seat Retention nut 2. Locate the spring inside the top center hole of the regulator bottom and place the large end of the stem inside of the spring. #2-009 o-ring 3. Lightly lube the new #2-009 o-ring with Krytox and then set it on top of the seat. Valve stem Seat/valve stem 4. Use a small tool to press the o-ring, seat, and stem snugly into the cavity (the white outer casing of a BIC pen works well). 5. Carefully, lightly lube only the threads of the seat retention nut with Krytox and then set it, non-threaded side first, on top of the seat. 6. Use a torque wrench/screwdriver with the spanner bit to torque the seat retention nut to 25 in/lbs. A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 geniefilters.com Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
12 PAGE 8 6. Replace the piston seal 1. Turn the regulator top upright to remove the components from within the regulator top. 2. Remove the o-rings from around the piston (5) and replace them with the new #2-015 o-rings from the kit. Once installed, lightly lube the o-rings. 3. Turn the top upside-down and install the components in the following order: Drop a spring button (1) in the regulator top with the pointed side up. Drop the load spring (2) in the regulator top. Drop a second spring button (3) in the regulator top with the pointed side down. Install the piston (5), small end first, into piston housing adapter (4). Install the piston housing adapter, small end first, in the regulator top. Replace the o-rings Pointed sides go inside the spring 7. Tighten the two halves together 1. Carefully apply a thin film of Loctite 243 thread adhesive to the threads of the regulator bottom. 2. With the regulator top still upside-down, screw the bottom and top together hand-tight. 3. Place the regulator in the vice in its upright position. 4. Use a torque wrench and 1.5 open end wrench/crow s foot to tighten the two halves together to 15 ft/lbs. 8. Install parts in top. 1. Install the new #2-206 o-ring along with the original bolt, nut, and washer in the top of the regulator. New o-ring 9. Install heater block 1. Refer to PAGE 5 section for instructions on installing the heater block. 10. Reinstall regulator in system 1. Refer to the INSTALLATION AND OPERATION section for instructions on mounting, powering, establishing flow, and setting pressure, etc. A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 geniefilters.com Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
13 PAGE 9 MODEL NUMBERING AND PRODUCT DIMENSIONS Model Numbering & Additional Part Numbers Your model number is determined by your specific needs. Materials of construction must be compatible with process fluid. Model GHR = GR with self-limiting block heater 901-GR = GR with temperature controller Sealing material 0 = Fluoroelastomer (standard) JW = RGD resistant HNBR (other materials available upon request) Outlet pressure range (psig) 0 = = = = = = 0-10 Power requirements 1= AC power 2 = DC power (not available in Model 901-GR) Electrical approval C = CSA A = ATEX/IECEx (not available in Model 901-GR) How to build the model number: Model Sealing material Outlet pressure range Power requirements Electrical approval Product Dimensions SS P 4 GHR How to build the heater block replacement model number: Power requirements Electrical approval Spare Parts & Accessories (sold separately) Kozy Insulated Cover - Part # KZ-10-L (not for enclosures) 901 Heater Base & Controller Replacement - Part # SS Genie Regulator Accessory Manifold - pressure gauge, ball valve & relief valve Inlet filter replacement - Part # GHR-5FSS 5 Side View Top View 2.2 ADJUSTMENT SCREW INLET PORT OUTLET PORT MOUNTING HOLES FOR 1/4-20 SCREWS CONDUIT CONNECTION A+ Corporation, LLC is the world leader in the invention and development of Genie Membrane Separators designed to accommodate a variety of industrial settings and specifications. Make sure you protect your gas sample system from damage while getting the most accurate representative gas sample possible. A+ Corporation, LLC is an ISO 9001:2008 Certified Company. U.S. Patent 5,476,586. Genie, Genie Membrane Technology, Genie Membrane Separators, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners A+ Corporation. All rights reserved. SCC-GHR-CSA-PM_0517 geniefilters.com Contact us for expert product application assistance sales@geniefilters.com Fax A+ Corporation, LLC Black Bayou Rd., Gonzales, LA 70737
14
15
16 MODEL SE620 - CSA VERSION Most common configuration is shown. Actual system may differ. VIEW 1-A ISO TOP LEFT SCALE 1:4 VIEW 1-B ISO TOP RIGHT SCALE 1:4 A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 VERTICAL, 750, GHR SHEET 1 OF 9 REV 1
17 750 GHR VIEW 2-A ENCLOSURE INSTALLED SCALE 1:3.5 VIEW 2-B ENCLOSURE REMOVED SCALE 1:3.5 A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 VERTICAL, 750, GHR SHEET 2 OF 9 REV 1
18 A3 A4 A2 A3 A5 A3 A1 VIEW 3-A ENCLOSURE REMOVED SCALE 1:3 VIEW 3-B 750 & GHR DIAGRAM SCALE 1:3 PARTS LIST ITEM DESCRIPTION A1 DD, 3/4" x 1" NPT ENCLOSURE COUPLING DD, 3/4" x 3/4" NPT ENCLOSURE COUPLING A2 DIRECT DRIVE PROBE, STAINLESS STEEL, 12" LENGTH DIRECT DRIVE PROBE, STAINLESS STEEL, 18" LENGTH DIRECT DRIVE PROBE, STAINLESS STEEL, 24" LENGTH A3 ELBOW, 1/8" TUBE x 1/4" MNPT A4 TUBING, 1/8" OD X 0.035" WT, 316SS A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 A5 GHR, STAINLESS STEEL VERTICAL, 750, GHR SHEET 3 OF 9 REV 1
19 B6 B4 B5 B3 B1 B3 B4 B5 VIEW 4-B OUTLET DIAGRAM SCALE 2:3 B2 B1 B1 PARTS LIST VIEW 4-A ENCLOSURE REMOVED SCALE 1:3 ITEM B1 B2 B3 DESCRIPTION TUBING, 1/8" OD X 0.035" WT, 316SS VALVE, BALL, 1/8" TUBE, 316SS TEE, 1/8" TUBE x 1/8" TUBE x 1/8" TUBE B4 CONNECTOR, PORT, 1/8", SS B5 ELBOW, 1/8" TUBE x 1/4" MNPT A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 B6 REDUCER, 1/4" TUBE X 1/8" TUBE VERTICAL, 750, GHR SHEET 4 OF 9 REV 1
20 C3 C4 C2 C3 C5 C2 C3 C6 C3 C1 VIEW 5-A ENCLOSURE REMOVED SCALE 1:3 VIEW 5-B STAND DIAGRAM SCALE 1:2.5 PARTS LIST ITEM DESCRIPTION C1 BRACKET, ENCLOSURE, ACES, VERTICLE, TUBE C2 COUPLING, BULKHEAD, 1/4" FNPT C3 GROMMET, PIPE, 1/2", FLEXIBLE PVC C4 ENTRY FITTING, CABLE, ENCLOSURE, HEAT SHRINK C5 GAUGE, 1/4" MNPT, 0-60 PSI A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 C6 PLUG, 1/4", HEX VERTICAL, 750, GHR SHEET 5 OF 9 REV 1
21 D1 D2 D3 D4 D8 D5 D6 D7 VIEW 6-B ELECTRICAL DIAGRAM SCALE 1:2 VIEW 6-A ENCLOSURE REMOVED SCALE 1:3 ITEM D1 D2 D3 PARTS LIST DESCRIPTION JUNCTION, CONDUIT, 1/2" NPT, ELBOW, LEFT NIPPLE, GENERIC CONDUIT, 1/2" X 4" GROMMET, PIPE, 1/2", FLEXIBLE PVC D4 ELBOW, CONDUIT, 1/2" MNPT X 1/2" FNPT D5 NUT, CONDUIT, LOCK, 1/2" D6 HEATER BLOCK, CKA T3, VAC, 80W, CSA D7 BRACKET, HEATER A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 D8 FASTENERS (STAINLESS STEEL SCREWS, WASHERS, & NUTS) VERTICAL, 750, GHR SHEET 6 OF 9 REV 1
22 12.2 in 12.3 in 8.6 in SAMPLE OUTLET, HEAT SHRINK TUBE BUNDLE ENCLOSURE TEMPERATURE GAUGE E in 15.3 in PRESSURE GAUGE FOR SAMPLE OUTLET ENCLOSURE LOCKING PIN POST REGULATOR 1/4" FNPT PORT (PLUGGED BY FACTORY) E1 VIEW 7-A FRONT SCALE 1:3.5 VIEW 7-B RIGHT SCALE 1:3.5 PARTS LIST A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 ITEM E1 E2 DESCRIPTION INSULATED INTERTEC ENCLOSURE, MINIBOX THERMOMETER, DIAL, CENTER BACK, F VERTICAL, 750, GHR SHEET 7 OF 9 REV 1
23 A VIEW 8-A SCALE 1: " OR 1.0" MNPT PROCESS CONNECTION 9.5", 15.5", OR 21.5" STANDARD INSERTION DEPTHS 12", 18", OR 24" STANDARD PROBE LENGTHS SECTION A-A SCALE 1:3.5 A A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 VERTICAL, 750, GHR SHEET 8 OF 9 REV 1
24 ROUTINE MAINTENANCE B VIEW 9-A 750 DIRECT DRIVE SCALE 1:2.5 SECTION B-B REPLACEMENT KITS SCALE 1:2.5 75X-5V0 (REPLACEMENT SEALS, PACKING GLAND) 75X-CMA-506 (DIRECT DRIVE MEMBRANE ASSEMBLY) B A+ Corporation, LLC A (225) GENIEFILTERS.COM DRAWN JUSTIN BLANCHARD CHECKED STEVEN CALVERLEY TITLE SIZE DWG NO A SE620 VERTICAL, 750, GHR SHEET 9 OF 9 REV 1
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE REGULATOR
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE REGULATOR MODELS IRD-1 IRD-2 IRD-4 IRD-6 DRAWING NUMBERS AD025BO AD081BA AD170BO AD260CO MANUAL NUMBER IOM-070 REVISION Rev. G, 09/02/2015 TABLE
More informationCylinder and Valve: AirHawk II Air Mask
Cylinder and Valve: AirHawk II Air Mask MAINTENANCE AND REPAIR MSA 011 (L) Rev. 0 MSA 2010 Prnt. Spec. 10000005389(I) Mat. 10104218 Doc. 10104218 Parts List Cylinder Replacement Kits Item P/N Description
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR MODEL LE-2SSKO DRAWING NUMBERS AD691BG AD691BGSYS.3 AD691BGSYS.4 AD691CC AD691CD AD691CG AD691CI MANUAL NUMBER IOM-069
More informationEscape Cylinder and Valve
Escape Cylinder and Valve MAINTENANCE AND REPAIR TAL 1601 (L) Rev. 2 MSA 2016 Prnt. Spec. 10000005389 (I) Mat. 10064389 Doc. 10064389 CYLINDER COMPONENTS Item Part No. Description 818159 5 Minute, Aluminum
More informationACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump
ACHL Series Pump Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump Catalog: 02-9245ME February 2013 Model # Serial # Drawing # Order # Mfg. Date Table of Contents page
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE MODELS AIP-1 AIP-2 DRAWING NUMBERS AD198CA AD198CM AD198CO AD198DK.1 AD455BG AD455BO AD455EO MANUAL NUMBER IOM-006 REVISION
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Automatic Insertion Heated Regulator High Voltage Model IHRA-4SS-220/230 100 or more inch insertion length The information in this manual has been
More informationONYX VALVE CO MODEL DAO-ADA Installation & Maintenance
ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-ADA pinch valve is an open frame valve without housing enclosure and fails last position on loss of air. This actuator
More informationONYX VALVE CO MODEL DAO-PFO Installation & Maintenance
ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFO pinch valve is an open frame valve without housing enclosure and fails open on loss of air. The actuator drives
More informationONYX VALVE CO MODEL DAO-PFC Installation & Maintenance
ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFC pinch valve is an open frame valve without housing enclosure and fails closed on loss of air. The actuator drives
More informationINSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.
ARCHON Industries, Inc. Washdown Stations Models WD2010L, WD2010, WD2010H Installation / Operation / Maintenance Instructions 1 This manual has been prepared as an aid and guide for personnel involved
More information6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material
5.2018.12.i 6200 Series Specifications The Flomore 6200 Series Pump line consists of a series of basic pump options all developed from a modular power unit. All units are pneumatically driven positive
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE CONDITIONING HEATED SYSTEM
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE CONDITIONING HEATED SYSTEM MODEL SCHS DRAWING NUMBERS AD822BU AD822BZ MANUAL NUMBER IOM-132 REVISION Rev. C, 4/20/2016 TABLE OF CONTENTS SAFETY
More informationCalibration and Switching Module. User s Manual. A Swagelok Pre-Engineered. Subsystem. Pre-engineered subsystems available in weeks, not months.
Calibration and Switching Module User s Manual A Swagelok Pre-Engineered Subsystem Pre-engineered subsystems available in weeks, not months. Field-tested design ensures optimum system performance. Contents
More informationONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance
ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx series CAR-PFO and CAP-PFO pinch valves fail open on loss of air. The simple spring and air bag arrangement drives
More informationSteam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions
INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-8-002-US October 2016 Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions These instructions should be read by the Company
More informationCirculation Kits for CP Pumps
Instruction Sheet P/N 08000C Description This instruction sheet covers two circulation kits for CP Pumps: Stainless steel circulation kit, with Viton O-rings Stainless steel circulation kit, with EPR O-rings
More informationKAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA
An ISO 900 certified company TEL + 73 784-0000 FAX + 73 784-000 Email Sales@Kam.com KAM IAS ISOKINETIC AUTOMATIC SAMPLER PER API 8.2, ASTM D477 AND ISO 37 User Manual IASMANUAL-053 3939 Ann Arbor Drive
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE MODEL AWL-3HP DRAWING NUMBER AD489AP MANUAL NUMBER IOM-116 REVISION Rev. C, 4/6/2018 TABLE OF CONTENTS
More informationPNEUMATIC SLIDING VALVE
INSTALLATION, OPERATION, & #: MM-SV001 6-23-09 Rev. A Page 1 of 8 PNEUMATIC SLIDING VALVE PART NUMBERS (Including, but not inclusive) SV704MSTS, SV714MSTS, SV754MSTS, SV764MSTS, SV774MSTS, SV706MSTS, SV716MSTS,
More informationPV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance
ACECO Valve P.O. Box 9 Mounds, Oklahoma 74047 PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance Doc. No.: IOM-PV4-.0 Date: 6/0-00 Revision: A Contents: Installation Operation
More informationI-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761
warning Read and understand all instructions before attempting to install, remove, adjust, or perform maintenance on any Victaulic piping products. Depressurize and drain piping systems before attempting
More informationMETERING VALVE 2" STEM GUIDED
2" STEM GUIDED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed
More informationWelker Probe Instrument Regulator with Liquid Eliminator Cartridge
Installation, Operation, & Maintenance Manual Welker Probe Instrument Regulator with Liquid Eliminator Cartridge Model LEFRD-4SS The information in this manual has been carefully checked for accuracy and
More informationHIGH PRESSURE CONTROL VALVE PISTON BALANCED
PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be
More informationSERIES 8100 HAND-OPERATED PRESSURE CALIBRATION UNITS
SERIES 8100 HAND-OPERATED PRESSURE CALIBRATION UNITS PORTABLE PRESSURE SOURCE USED WITH A PRESSURE GAUGE TO FIELD CALIBRATE A VARIETY OF PRESSURE DEVICES, i.e., PRESSURE SWITCHES, GAUGES, DIFFERENTIAL
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER MODELS F-7 F-8 DRAWING NUMBERS AD045B[ ] AD046BB AD046BO MANUAL NUMBER IOM-113 REVISION Rev. B, 3/22/2017 TABLE OF CONTENTS SAFETY 3 1. PRODUCT
More informationMUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2
operating Instructions manual MUELLER GAS TAble of contents PAGE TM Unit 812 PE Line Stopping General Information 2 Equipment, Parts and Dimensions 3-5 Operating Instructions 6-12 Troubleshooting and Storage
More informationPRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY
PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been
More informationHard Seat Fluid Pressure Regulator
Instruction Sheet P/N 04742-02 Description The Nordson hard seat fluid pressure regulator is designed for use with abrasive coatings. The regulator body is constructed of stainless steel with a nickel-plated
More informationINSTALLATION AND MAINTENANCE OF TOP LOADING ARM
INSTALLATION AND MAINTENANCE OF TOP LOADING ARM D TABLE OF CONTENTS 1. INTRODUCTION 04 2. SPECIFICATION OF THE REDLANDS LOADING ARM 04 3. INSTALLING THE LOADING ARM 3.1. Installation Procedures 05 4.
More informationWelker Jet Insert Model Control Valve
Welker Jet Insert Model Control Valve Model WJ-1N, WJ-2N, WJ-4N, WJ-6N, & WJ-8N The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation,
More informationONYX VALVE CO MODEL DAC-PFO Installation & Maintenance
ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance OPERATION: (01-10) The Onyx series DAC-PFO pinch valve fails open on loss of air. This simple spring and air bag arrangement that drives a pair of
More informationDISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control
Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control BRADLEY SC A S53-141 4" Centerset S53-148 4" Centerset, no Solenoid Valve S53-186 4" Centerset with 8" Trim Plate S53-285 Centershank
More informationWelker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP
Installation, Operation, & Maintenance Manual Welker Sampler Model GSS-4HP The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct
More informationTemperature Sensor Series
GENERAL DESCRIPTION The patented* No. 85026-Series Temperature Sensor contains a two-position valve operated by temperature variations around the integral sensing bulb. It is used to vent or block a pneumatic
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP MODEL SSO-9MED DRAWING NUMBERS AD243DI AD243DK AD243DK.K1 MANUAL NUMBER IOM-175 REVISION Rev. B, 3/21/2017 TABLE OF CONTENTS
More informationEasy Tool Retracting System SR2159
Easy Tool Retracting System SR2159 Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358-4202 Fax: (256) 358-4515 E-mail: msc@alspi.com
More informationI-799/79V Coil Components
WARNING Read and understand all instructions before attempting to install any Victaulic products. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP MODEL SSO-8 DRAWING NUMBERS AD148CF AD148CG AD148CO AD148CQ AD500CA MANUAL NUMBER IOM-065 REVISION Rev. A, 8/17/2016 TABLE OF CONTENTS
More informationand 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec (I) Mat Doc
and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec. 10000005389 (I) Mat. 10064383 Doc. 10064383 REGULATOR COMPONENTS Item Part No. Description 1 MASK MOUNTED REGULATOR ASSEMBLY
More informationMaterial Specifications
5.2012.12.b 6200 Series Specifications The Flomore 6200 Series Pump line consists of a series of basic pump options all developed from a modular power unit. All units are pneumatically driven positive
More informationMicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves
MicroCoat System Operating Manual MC Series MC785M, MC785M-WF Spray Valves A NORDSON COMPANY Introduction The MicroCoat System provides precise lubrication control for metal stamping operations. The MC
More informationPipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.
Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 C 05/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifi cations.
More informationFisher D2T FloPro Control Valve
Instruction Manual D2T FloPro Valve Fisher D2T FloPro Control Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Specifications... 3 Installation... 3 Setting
More informationPaint/Solvent/Dump Valve and Flow-Through Valve
Instruction Sheet P/N 08573D Paint/Solvent/Dump Valve and Flow-Through Valve. Description See Figure. The paint/solvent/dump valve is a normally-closed valve that opens to trigger and/or dump coating material.
More informationANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood TABLE OF CONTENTS 1. General valve description and start-up... 1 2. Main valve maintenance... 1 3. Pilot maintenance... 5 4. Pilot
More informationMaintenance Information
16572679 Edition 2 May 2014 Air Drill QP Series Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these potentially
More informationLEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES
LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE
More informationAudi-Larm TM Audible Alarm: AirHawk II Air Mask
Audi-Larm TM Audible Alarm: AirHawk II Air Mask MAINTENANCE AND REPAIR MSA 011 (L) Rev. 0 MSA 2010 Prnt. Spec. 10000005389(I) Mat. 10104323 Doc. 10104323 REPLACEMENT KITS AND PARTS LIST Item P/N Description
More informationButterfly valves Figure 56 Installation & Maintenance Instructions
KEYSTONE Please read these instructions carefully This symbol indicates important messages and safety instructions. Hazard potentials: disregarding of instructions improper use of product insufficiently
More informationMicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:
MicroCoat System Operating Manual MC2 Series MC785, MC785-WF Spray Valves A NORDSON COMPANY US: 8-498-8865 UK: 8 585733 Mexico: 1-8-556-3484 Introduction The MicroCoat System provides precise lubrication
More informationValtek Auxiliary Handwheels and Limit Stops
Valtek Auxiliary s and Limit Stops Table of Contents Page 1 General information 2 Installation 2 Side-mounted handwheels, size 25 and 50 (linear actuators) 3 Side-mounted handwheels, size 100 and 200 (linear
More informationPneumatic Division North America Richland, MI 49083
Pneumatic Division North America Richland, MI 08 Installation Instructions: V-0P /8" Valvair II/A Series Valves Single Operated ISSUED: May, 00 Supersedes: November, 8 ECN #6 Rev. 6 WARNING To avoid unpredictable
More informationATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017
ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue 2017.1, Released December 13, 2017 Clark Cooper A Division of Magnatrol Valve Corp. 941 Hamilton avenue Roebling,
More informationI-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING
INSTALLATION AND MAINTENANCE INSTRUCTIONS I-VIC300MS Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 61 Vic-300 MasterSeal Stainless Steel Butterfly Valve SERIES 761 SERIES 61 Read and
More informationKimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.
TREATER VALVE All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed
More informationB21 Series BASOTROL Gas Valve
Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully
More informationMEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody
MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody I INTRODUCTION These rugged, versatile, high performance, regular port, ball valves meet all requirements
More informationPage 1 of 26 Oteco Inc. Houston, Texas
Page 1 of 26 Page 2 of 26 1.0 OVERVIEW CONTENTS 2.0 INSTALLATION GUIDELINES 2.1 Preferred Valve Orientation 2.2 Pressure Rating and Orientation of Discharge line 2.3 Reaction Forces and Anchoring of Reset
More informationOperation and Maintenance Manual
BM / BMA Hydrometers ½ Operation and Maintenance Manual i This manual is intended for use by the users of this equipment. The information contained herein is the property of the Arad Ltd. Dalia and may
More informationINSTALLATION & OWNER S MANUAL
INDUSTRIES, LLC. INSTALLATION & OWNER S MANUAL CAB INSTALLATION INSTRUCTIONS KUBOTA GRAND L 40 SERIES HARD SIDED CAB ENCLOSURE (p/n 1KGL4AS) This Curtis Cab is designed and manufactured for use only as
More informationDISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model
More informationIdeal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators
I & M Mark (/ ) 0 Wasson Road Cincinnati, OH 0 USA Phone --00 Fax -8-00 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark Pressure Regulators Warning: Jordan Valve
More informationCrispin Valves Operating Guide. Crispin
Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual Technical Manual EH 1.2 General Information about valve sizing: Valves with a Full Port have an internal seat diameter that is the same as the nominal pipe
More informationPFA LINED BALL VALVES Installation, Operation and Maintenance Manual
ACRIS PFA LINED BALL VALVES WWW.AMRESIST.COM Table of Contents Safety Instructions - Definition of Terms............................................2 Introduction..............................................................2
More informationSecond Stage Regulator - 1/4 Turn
Second Stage Regulator - 1/4 Turn MAINTENANCE AND REPAIR TAL 806 (L) Rev. 6 MSA 2008 Prnt. Spec. 10000005389 (I) Mat. 10042827 Doc. 10000015245 1/4 TURN SECOND STAGE REGULATOR SECOND STAGE REGULATOR COMPONENTS
More informationMODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM
MODEL NUMBER: 10003 MEDIUM DUTY ONBOARD AIR SYSTEM IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using
More informationLOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED
DIAPHRAGM BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER TELESCOPING INSERTION
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER TELESCOPING INSERTION DRAWING NUMBER AD905BB MANUAL NUMBER IOM-188 REVISION Rev. A, 7/8/2016 TABLE OF CONTENTS SAFETY
More informationOPERATOR S MANUAL A
OPERATOR S MANUAL 670144-A INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 12-18-15 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) (REV: A) 67 0144-A READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
More informationREAD INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION
INSTALLATION INSTRUCTIONS Hot Fox In-Tank Fuel Warmer READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION Models covered by these instructions include: HFG 0-0 HFG 0- SHFT--0- SHH--0 TWHF 0- HFG
More informationINSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website
INSTALL MANUAL FOR ON LINE ORDERING- E Commerce Visit Our Website WWW.PRESSUREGUARD.COM Contact Information Technical Support: Chris@pressureguard.com Sales Support: Sales@pressureguard.com By Phone: 615-227-6024
More informationBlow Off Valve Retrofit Kit
Instruction Sheet P/N 37 56C low Off Valve Retrofit Kit WRNING: llow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation..
More informationMODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416
MODEL HD-BTC Installation, Operation & Repair Parts Information REV041416 TABLE OF CONTENTS SAFETY INSTRUCTIONS 1 DEFINITIONS 1 SPECIFICATIONS 2 INSTALLATION INSTRUCTIONS 2 OPERATING INSTRUCTIONS 2 MAINTENANCE
More informationHFB Steering Gear Service Manual
TRW Automotive Commercial Steering Systems HFB Steering Gear Service Manual HFB64 SERIES Die Cut HFB64 Integral Hydraulic Power Steering Gear This steering gear was specifically designed for motor trucks;
More informationTri-Clover Manual and Air Actuated Fractional Valves
FVSM-99 Tri-Clover Manual and Air Actuated Fractional Valves Series 650 655 660 CONTENTS Thank you for purchasing a Tri-Clover Product! This manual contains disassembly and assembly instructions, maintenance
More information2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters
2311FA Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA 56-101-00212 Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters 4101 Northwest 29th Street Miami, Florida 33142 www.barfieldinc.com
More informationY690A Series Pressure Reducing Regulators
Instruction Manual Form 5463 Y690A Series April 1999 Y690A Series Pressure Reducing Regulators Introduction Scope of Manual This manual provides instructions for installation, startup, maintenance, and
More informationTK-6024, TK-6124, TK-8024, TK-8124
TK-6024, TK-6124, TK-8024, TK-8124 Pneumatic Bulb Thermostats General Instructions APPLICATION For proportional temperature control of pneumatic valves and actuators to maintain air or liquid temperatures
More informationInstallation, Operation, and Maintenance Manual
Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2
More informationWelker Automatic Insertion Diffusing Probe Model AIP-3DP
Installation, Operation, and Maintenance Manual Welker Automatic Insertion Diffusing Probe Model AIP-3DP The information in this manual has been carefully checked for accuracy and is intended to be used
More informationPipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.
+GF+ SIGNET 0 High Performance Flow Sensor (English) -0.090- F-/99 English SAFETY INSTRUCTIONS. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifications.. Do not
More informationKEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood HAZARD POTENTIALS disregarding of instructions improper use of product insufficiently qualified personnel Valve application to be
More informationONYX VALVE CO MODEL CER with JORDAN ACTUATOR Installation & Maintenance
ONYX VALVE CO MODEL CER with JORDAN ACTUATOR Installation & Maintenance OPERATION: (7-2011) The Onyx series CER is electric operated pinch valve, with full round configuration and a single pinching mechanism.
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FUEL SURGE TANK INSTALL KIT Honda S2000 Document# 19-0063 Support: info@radiumauto.com WARNING: DO NOT SMOKE WHILE WORKING ON FUEL SYSTEMS. KEEP SPARKS AND OPEN FLAMES AWAY FROM
More informationTWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air
ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet
More informationDP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10
DP5 Pump 5:1, Air-operated, Heavy Duty, Oil General The DP5 Pump is a compressed air-operated reciprocating piston medium pressure pump. These pumps are suitable for distribution of all types of light
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER FIXED INSERTION
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER FIXED INSERTION DRAWING NUMBER AD887AC MANUAL NUMBER IOM-178 REVISION Rev. 0, 7/8/2016 TABLE OF CONTENTS SAFETY 3 1.
More informationWelker Jet Top Entry Control Valve
Installation, Operation, & Maintenance Manual WJTECV-001.02 Welker Jet Top Entry Control Valve The information in this manual has been carefully checked for accuracy and is intended to be used as a guide
More informationBaumann Series Flexsleev Control Valve Instructions
Instruction Baumann 86000 Series Instructions Baumann 86000 Series Flexsleev Control Valve Instructions Contents Introduction...1 Scope...1 Safety Precautions...1 Maintenance...2 Installation...3 Air Piping...3
More informationVSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500
VSI INDUSTRIAL BALL BUTTERFLY VALVES VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500 INSTALLATION, OPERATION AND MAINTENANCE MANUAL
More informationRosemount 402 and 402VP
Rosemount 402 and 402VP Contacting Conductivity Sensors Instruction Manual LIQ-MAN-402 Rev. M May 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and
More informationPRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS
OWNER'S MANUAL SAVE THESE INSTRUCTIONS PRO20-115 PRO20-115RD 115-Volt AC PRO20-115AD Automatic Diesel Nozzle PRO20-115MD Manual Diesel Nozzle PRO20-115PO Pump Only PRO20-115RD For Remote Dispensing Systems
More informationSEAL REPLACEMENT SeaStar ATM, Inboard Steering Cylinders, -3 Models
Copy Part# 343321, Rev. D, 05/2015 Page 1 of 6 SEAL REPLACEMENT SeaStar ATM, Inboard Steering Cylinders, -3 Models CAUTION Applicable Cylinders Throughout this publication, Warnings and Cautions (accompanied
More informationTypes C401, C402, C407, C421, C427, C403, and C831 Jet Bleed Internal Valve Retrofit Kits
Instruction Manual MCK-2290 Types C401, C402, C407, C421, September 2012 Types C401, C402, C407, C421, C427, C403, and C831 Jet Bleed Internal Valve Retrofit Kits! Warning Failure to follow these instructions
More informationM-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components
Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options
More informationFisher 657 Diaphragm Actuator Sizes and 87
Instruction Manual 657 Actuator (30-70 and 87) Fisher 657 Diaphragm Actuator Sizes 30 70 and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Mounting
More information100 Series Flow Switches Technical Reference Manual
Proteus Industries Inc. 100 Series Flow Switches Technical Reference Manual Can we Improve? Tell our President! Can we improve our product, our support or this manual? We are committed to continuous improvement
More information