792 LED USER MANUAL GB
|
|
- Stella Johnson
- 5 years ago
- Views:
Transcription
1 792 LED USER MANUAL GB
2 LIST OF CONTENT 1 General information... 3 The layout of this manual The use of the manual Manufacturer information Document information Overall 792 information Relevant standards Main data LED 792 variants Warranty limitations DESCRIPTION General Information LED electronics Light output performance Installation Unpacking the 792 LED fixtures Installation consideration Installation in the field Maintenance In the field In the workshop Specifications List of spares Assembling drawing List of components, see drwg Certificates
3 1 General information The layout of this manual This manual includes technical information about the Hella Induperm range of Unidirectional high intensity LED fixtures. The range of 792 LED fixtures are constructed and manufactured of standard parts mostly produced in-house. A large part of the mechanical construction, the LED modules as well as the electronic are used in a number of Hella and Hella Induperm light fixtures. This reduces the necessary amount of spares in an airport. 1.1 The use of the manual The manual is intended to be used for installation, operation, maintenance of the 792 LED, as well as for purchase of spare parts. 1.2 Manufacturer information The LED 792 are developed and manufactured by: HELLA INDUPERM A/S Københavnsvej 1 DK-4800 Nykøbing Falster DENMARK Tel.: Fax.: induperm@induperm.dk Homepage: or Document information Version Date Author Approved A First release Ole Lund-Hermansen OLH Version Date Author Approved Comments Aa OLH OLH List of components revised This manual includes a number of safety instructions, but national instructions as well as IEC 61820, Annex C, must be observed. Hella Induperm A/S reserves the right to changes without notice. It is not allowed to copy this manual without permission. 3
4 2 Overall 792 information 2.1 Relevant standards The range of 792 High Intensity is constructed, manufactured and tested to meet the requirements in ICAO annex 14, and meets the light output requirements given on the Isocandela diagrams in Appendix 2 for the relevant light systems (Approach, Siderow, Threshold etc.). The light fixtures also meet the FAA requirements to ALS systems. The Average intensities are meet with maximum 50W /Light output. Lightweight construction with no heavy parts above ground level. 2.2 Main data The 792 LED light fixtures uses the same technology and main parts as used in unidirectional LED light fixture type 921 for RGL. Designed to meet all environmental conditions given in FAA AC No. 150/ D where applicable. Standard height app. 355mm, but other heights can be supplied upon request. Standard 100% input current is 6,6A, and the fixtures can be dimmed to 2,2A. Features The outside of the front glasses is smooth and needs no cleaning Extremely easy levelling and adjustment due to patented ball joint. No adjustment after change of LED module or electronics. Only fully, corrosion proof components are used. Finished in stove enamel aviation yellow, RAL 1028 Two types of breakable couplings available: Type A for 2 thread Type C for Ø-2 (60mm) pole mounting Shipping details per fixture: 4Kg / 0,05m3 2.3 LED 792 variants a. Input cable The 792 light fixtures can of course be supplied with cable with a standard FAA 2-pole plug (Style 1), but when used on poles an FAA connector might not be needed an a direct connection with 6,3mmAPM could be a cheaper solution. b. Fail Open relay The 792 fixtures can be supplied with or without a Fail Open relay. The Fail Open relay can be programmed for customer specified functions. c. Height of fixture. The 792 LED light fixture can upon request be quoted in customer specified heights. 4
5 d. List of variants. This Manual is valid for the following 792 LED variants: Hella Induperm Type No. Hella Type No. Application Description Colour 792.LED.1.0.C Approach APH-Elevated-clear-LED-breakable coupling C C 792.LED.1.0.A Approach APH-Elevated-clear-LED-breakable coupling A C 792.LED.1.4.C Approach APH-Elevated-clear-LED-breakable coupling C, C 792.LED.1.4.A Approach APH-Elevated-clear-LED-breakable coupling A, C 792.LED.2.0.C Side Row SR-Elevated-red-LED-breakable coupling C R 792.LED.2.0.A Side Row SR-Elevated-red-LED-breakable coupling A R 792.LED.2.4.C Side Row SR-Elevated-red-LED-breakable coupling C, R 792.LED.2.4.A Side Row SR-Elevated-red-LED-breakable coupling A, R 792.LED.3.0.C Threshold THR-Elevated-green-LED-breakable coupling C G 792.LED.3.0.A Threshold THR-Elevated-green-LED-breakable coupling A G 792.LED.3.4.C Threshold THR-Elevated-green-LED-breakable coupling C, G 792.LED.3.4.A Threshold THR-Elevated-green-LED-breakable coupling A, G 792.LED.4.0.C Runway End END-Elevated-red-LED-breakable coupling C R 792.LED.4.0.A Runway End END-Elevated-red-LED-breakable coupling A R 792.LED.4.4.C Runway End END-Elevated-red-LED-breakable coupling C, R 792.LED.4.4.A Runway End END-Elevated-red-LED-breakable coupling A, R 792.LED.STB.0.C Not yet done Stopbar STB-Elevated-red-LED-breakable coupling C 792.LED.STB.0.A Not yet done Stopbar STB-Elevated-red-LED-breakable coupling A 792.LED.STB.4.C Not yet done Stopbar STB-Elevated-red-LED-breakable coupling C, 792.LED.STB.4.A Not yet done Stopbar STB-Elevated-red-LED-breakable coupling A, 2.4 Warranty limitations The manufacturer or his representative cannot be held responsible for failures and malfunctions, if the instructions in this manual are not followed. The 792 LED meet all specifications when installed and operated as specified. Hella Induperm A/S only has responsibility to replace faulty parts if construction, production or component failure is proven DESCRIPTION 3.1 General Information Hella Induperm 792 light fixtures are constructed mainly by using standard components from Hella- Induperm standard program of elevated fittings. The light system can easily be adjusted for toe-in and elevation. The fitting has a breakable coupling, designed for 2 (60mm) stake mounting (Type C) or with 2 thread stub (Type A). The light fixture is designed for an expected lifetime for the LED s of Hours. 5
6 LED electronics The driver electronic for the LED modules are identical to the electronics used in Hella inset lights and in Hella Induperm elevated LED lights fixtures. The electronic will transfer the RMS value of the 6,6A series circuit current into the necessary LED current. The electronic is informed about the LED current needed from the EPROM memory on the LED module. 3.3 Light output performance Three parameters are essential for the correct light output. The color of the LED output together with the color of the front glass defines the correct color. The LED light output together with the lens on each LED defines the correct light distribution. 4 Installation 4.1 Unpacking the 792 LED fixtures The 792 units are supplied in individual boxes. Please make sure that nothing is broken before starting installation. As standard, the light fixtures are not pre-adjusted in the factory and must be adjusted before taken into operation. 4.2 Installation consideration The correct installation procedure is with an adjustment performed with the light fixture mounted in the final position. However, in some cases with high tilt-able poles it might be the only solution to pre-adjust the light fixture in the workshop before mounting on the pole. If so, the correct alignment of the pole must be controlled. 4.3 Installation in the field The light fixture is electrical connected and mounted with the breakable coupling. A Hella Induperm adjustment tool type or is mounted on the fixture and the fixture is adjusted as described for the tool. 5 Maintenance 5.1 In the field Every 6 month: The elevation and Toe-in adjustments are controlled Regularly: Front glass is cleaned if necessary, and a visual control of similar light output from both light units. 6
7 5.2 In the workshop Changing the front glass Pic. 1 Pic. 2 Use a small screwdriver to press out the spring Pic. 3 Pic. 4 The spring and front glass scan be removed Pic. 5 The aluminum ring with rubber gasket must be thoroughly controlled and eventual exchanged. By assembling again, please observe the groove in the ring. This must be positioned correctly by the rivet in the light fixture. 7
8 5.2.2 Changing the complete 792 LED light unit 6 Specifications Light output according to ICAO Annex 14 Figure and 2.8 (see enclosed Certificates) 100% current 6,6A, power consumption app. 50W Expected LED lifetime of H Standard overall height app. 355mm. Other heights upon request. Weight app. 4 KG Ingress Protection IP 54 Supplied with breakable coupling type A (2 Thread) or C (60mm tube) Connection with FAA plugs Style 1 or 6,2mm AMP spades Finished in stove enamel aviation yellow RAL 1028 Can be supplied with Fail-Open Relay (or relays) Can be supplied with base plate (optional) 8
9 7 List of spares 7.1 Assembling drawing 9
10 7.2 List of components, see drwg. 7.1 Pos. Name Type Number p. Light 1a Frontglass, clear P /1 1b Frontglass, red P /1 1c Frontglass, green P /1 2 Spring for frontglass /1 1 3 Alu-housing LED spare light unit for a APH,THR 0/1 792 LED spare light unit for b STP,END 0/1 5 Cover with Electronic HKG Gasket for Electronic HKG PVC-roundel P O-ring gasket /1 1 9 Stainless lock P a Breakable coupling type C /1 Breakable coupling type A (2" b thread) 0/1 11 Cable w. FAA plug style /1 AMP connector kit for field a mounting on incoming cable 0/ Adjustment fixing assembly P Flat-band cable P
11 8 Certificates 11
12 12
13 13
14 14
Runway Guard Lights RGL 921 USER MANUAL GB
Runway Guard Lights RGL 921 USER MANUAL GB LIST OF CONTENT 1 General information... 3 The layout of this manual... 3 1.1 The use of the manual... 3 1.2 Manufacturer information... 3 1.3 Document information...
More informationPAPI System Hella Induperm type 801 USER MANUAL GB
PAPI System Hella Induperm type 801 USER MANUAL GB LIST OF CONTENT 1. General information... 3 1.1 The layout of this manual... 3 1.2 The use of the manual... 3 1.3 Manufacturer information... 3 1.4 Document
More informationTaxiway Centerline Light Type TCL and Type TCC
LED Airport Lighting Brief-Information Taxiway Centerline Light Type TCL and Type TCC Reduced CO 2 emission by up to 85 % Up to 50,000 hrs LED service life Reduce maintenance and repair by up to 70 % Straight
More informationTraffic Guidance Signs Type TGS and Retrofit-Kit
LED Airport Lighting Brief-Information Traffic Guidance Signs Type TGS and Retrofit-Kit Reduced CO 2 emmision by up to 85 % Up to 50,000 hrs LED service life Reduce maintenance and repair by up to 70 %
More informationINSTALLATION DOCUMENTATION for EL-AT
DOC 2101.E INSTALLATION DOCUMENTATION for EL-AT www.thornairfield.com THORN EUROPHANE 156 bd Haussmann 75379 Paris Cedex 08 FRANCE Tel : +33 (0) 1 49 53 62 62 Fax : +33 (0) 1 49 53 62 89 Thorn DNT Airfield
More informationAirfield Lighting Product Description Unidirectional High-Intensity Elevated Light (IDM 6301) Elevated Runway Guard Light Road Holding Position Light
Product Description Unidirectional High-Intensity Elevated Light (IDM 6301) Elevated Runway Guard Light Road Holding Position Light Safegate Group Note: This page is blank for convenient double-sided printing.
More informationFTS/FTC TAXIWAY LIGHTING. Taxiway Centerline, Stop Bar and Intersection Inset Light MEDIUM-INTENSITY. Compliance with Standards.
Taxiway Centerline, Stop Bar and Intersection Inset Light MEDIUM-INTENSITY Compliance with Standards FAA: Fittings for straight sections in compliance with FAA L-852A and L-852C specification, AC150/5345-46
More informationILED Dorado. User Manual
10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...
More informationL-801 HBM 150/2 Airport Rotating Beacon Compliant with Standards: FAA: L-801 AC 150/ (Current Edition) ICAO: Annex 14, para 5.3.
L-801 HBM 150/2 Airport Rotating Beacon Compliant with Standards: FAA: L-801 AC 150/5345-12 (Current Edition) ICAO: Annex 14, para 5.3.3 This Hali-Brite beacon is designed for night operation as an identification
More informationWLTwin77 Twin Aviation Obstruction Light. Data Sheet. Rev: 1.1
WLTwin77 Twin Data Sheet Rev: 1.1 Description: The ICAO compliant type B WLTwin77 Dual aviation obstruction light is suitable for marking of high rise structures. These structures can be Steel Towers (such
More informationPAPI PU3L AIRFIELD LIGHTING. Precision Approach Path Indicator. PAPI or APAPI. Visual Precision Approach Path Indicator Systems. Location on the Field
Precision Approach Path Indicator PAPI or APAPI Visual Precision Approach Path Indicator Systems Introduction The PU3L is an equipment to be used as a unit in PAPI (four units) and APAPI (two units) systems.
More informationAirfield Lighting. Bidirectional High-Intensity Elevated Light (IDM 5848) Product Description. Runway Edge
Product Description Bidirectional High-Intensity Elevated Light (IDM 5848) Runway Edge Note: This page is blank for convenient double-sided printing. 1. INTRODUCTION IDM 5848 is a high-intensity bidirectional
More informationILED Aquarius Illuminated Windsock. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...
More informationDELTA RAIL SYSTEM SYMMETRIC OPTICAL SYSTEM STANDARD SPECIFICATIONS DR 1 320MH-PS. 29,700 36,000 40, , mm 400MH 400MH-PS 1000MH-BT37 DR 2
SPECIFICATIONS DELTA RAIL SYSTEM SYMMETRIC OPTICAL SYSTEM STANDARD Number of Lamps Lamp Type All smaller wattages available Lumen Package Initial lumens, based on published lamp information 004 DR 405mm
More informationComplete Solar Airfield Lighting Solutions
AVIATION LIGHTING Complete Solar Airfield Lighting Solutions Avlite Systems is an international designer & manufacturer of complete aviation lighting systems; airfield, heli & obstruction. AVIATION LIGHTING
More informationILED Aquarius CIRCLE-H Helideck Lighting System
ILED Aquarius CIRCLE-H Helideck Lighting System Low profile - Less than 25 mm Precision Machined Interlock Mounting System Special Anti-slip Coating Why CIRCLE-H? Helicopter deck signalisation lighting
More informationWE KEEP YOUR DOORS FUNCTIONING IN ALL CONDITIONS
PVC TECHNOLOGY IN MOTION www.maco.eu WE KEEP YOUR DOORS FUNCTIONING IN ALL CONDITIONS HINGE SYSTEMS FOR PVC DOORS Door hinges for any requirement MACO door hinges are suitable for use on all doors with
More informationRunway Edge High Intensity Bidirectional Elevated Light
Instruction Manual AM.03.111e Edition 2.4 Runway Edge High Intensity Bidirectional Elevated Light Type BPE 2-150 RECORD OF CHANGES Rev. Page Description Checked Approved 1.0 32 New clamping ring WM LM
More informationPAH, PAHT, PAHT G pumps PAH , PAHT and PAHT G Disassembling and assembling
Servie guide PAH, PAHT, PAHT G pumps PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5 Disassembling and assembling hpp.danfoss.com Table of Contents 1. Disassembling the pump...3 2. Inspection...7 2.1. Port
More informationMedium Intensity Omnidirectional Elevated Light
Instruction Manual Medium Intensity Omnidirectional Elevated Light Type RVE 3-045 RECORD OF CHANGES Revision Page Description Checked Approved 1 27 Modification 4.1 CME - 2 Rebranding EV 12/09 1 SAFETY
More informationUSER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.
User Manual ZSP100 Document No. 0658.00.95-03.2 Page 1/6 MERAWEX Sp. z o.o. Toruńska 8 44-122 Gliwice Poland tel. +48 32 23 99 400 fax +48 32 23 99 409 merawex@merawex.com.pl http://www.merawex.com.pl
More informationPOINT CIRCLE-H LIGHTS PTPS LED TOUCHDOWN & POSITIONING SYSTEM LIGHTED TD/PM CIRCLE & H MARKINGS
Compliances: Listed 1180 II 2 G Ex e mb IIC T6 Gb Tamb -45 to +55 deg C, IP66 & IP67 Listed ATEX Directive 94/9/EC Annex VI & RoHS Directive: 2011/65/EU ATEX Certificate Numbers: TRAC14ATEX0064X & TRAC15ATEX0052X
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationL-862 AND L-862E HALOGEN HIGH INTENSITY RUNWAY LIGHT
INSTALLATION AND MAINTENANCE MANUAL L-862 AND L-862E HALOGEN HIGH INTENSITY RUNWAY LIGHT PNs: L-862-XXX-XX-XX L-862E-XXX-XXX-XX DME CORPORATION 6830 N.W. 16 th TERRACE FT. LAUDERDALE, FLORIDA 33309 This
More informationAirfield Lighting. Omnidirectional Medium-Intensity Elevated Light (IDM 2927) Product Description
Product Description Omnidirectional Medium-Intensity Elevated Light (IDM 2927) Approach Centre Line and Crossbars for Non-Category Lighting Systems Note: This page is blank for convenient double-sided
More information1 Planning Information
Rudder Centering Fork - Control Stop Replacement 1 Planning Information 1.1 Affected Aircraft Type: Model: Serial Number: Applicable Countries: CT CTLS 1.2 Concurrent Documents None 1.3 Reason F-08-10-21,
More informationSetting up a Topper 7
Contents Page General Information 1 Items Supplied 1 Variants 1 Fitting a Housing 2 Mounting a Topper 3 Safety Precautions 4 Control Connections 4 Setting up a Topper 7 Metham Aviation Design Limited station
More informationOptimized LED Installation
New Kassel-Calden Airport Optimized LED Installation Presented by Helmut Hengvoss Helge Mack New Kassel-Calden Airport Topics The Kassel-Calden Airport project Used technology concepts The implementation
More informationPOINT HELIPORT LIGHTS
HELIPORT LIGHTING SPECIFICATION GUIDE INCANDESCENT LIGHT SOURCES * POINT HELIPORT LIGHTS POINTUSA The following pages provide suggested lighting equipment specifications for simple private-use ground based
More informationWIRE ROPE HOISTS & TROLLEYS. XM Series MISIA HOISTS & LIFTING SOLUTIONS
WIRE ROPE HOISTS & TROLLEYS XM Series MISIA HOISTS & LIFTING SOLUTIONS INDEX MISIA THE COMPANY 2 QUALITY AND CERTIFICATIONS 4 MISIA WIRE ROPE HOISTS XM SERIES 6 Standard configurations 8 Components 10
More informationFlow Meter Terminal Boxes
Shutter Flow Meter Terminal Boxes Shutter Flow meter Terminal boxes 02 07 11 1 Shutter Valve DAROC Description and general specifications Production range and operating conditions Operation Installation,
More informationDisassembling and assembling PAH , PAHT and PAHT G
MAKING MODERN LIVING POSSIBLE Instruction Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5 danfoss.high-pressurepumps.com Table of Contents 1. Disassembling...3 2. Inspection...7
More informationDL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless
More informationSafeSite LED Based Signaling for Hazardous Locations
SafeSite LED Based Signaling for Hazardous Locations On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDTFSFSTBROCHURE_H Features & Benefits 5 year warranty
More informationabcd AIRPORT EQUIPMENT INSTALLATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS LIST
AIRPORT EQUIPMENT INSTALLATION AND MAINTENANCE INSTRUCTIONS and SPARE PARTS LIST for the SWITCHABLE, 203MM (8 ) HIGH INTENSITY, INSET TAXIWAY CENTRELINE & STOPBAR FITTINGS TYPE ZA280S & ZA281S Ref : L:\
More informationIQL Helios Area-/Streetlight. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...
More informationPOINT WIND CONE PWC FAA L-806 & L-807
Compliances: ETL Verified FAA L-806 FAA Advisory Circular 150/5345-27E ETL Verified FAA L-807 FAA Advisory Circular 150/5345-27E Registered ISO 9001:2008 Transport Canada TP312, Chapter 5 Visual Aids ICAO
More informationInstallation instructions. Adapter AD 01 AD 02 AD 03
Installation instructions Adapter AD 0 AD 0 AD 03 Table of contents Safety information..... Meaning of safety symbols... General safety information... 3 Introduction... Operation... 3 3. 4 Operating faults...
More informationOperating Instructions
Operating Instructions LRM 1218 Solar Charge Regulator Table of contents 1 Safety information... 2 1.1 Meaning of safety symbols... 2 1.2 General safety information... 2 2 Introduction... 3 2.1 Purpose...
More informationDatasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX
Just as reliable as the tried-and-tested original, with innovation in detail: the BLF 5.08 the PUSH-IN version of the BLZ 5.08 female header features a new connection system and a more compact design.
More informationHALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &
HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: 5460600 & 5460595 OPERATING & MAINTENANCE INSTRUCTIONS GC0610 INTRODUCTION Thank you for purchasing this CLARKE Halogen Floodlight. Before attempting
More information0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd
0CV2 0CV2 series dust explosion-proof three-phase asynchronous motor INSTRUCTIONS Siemens Standard Motors Ltd. 2017.02 1.0 Overview 0CV2 0CV2 series dust explosion-proof three-phase asynchronous motor
More informationTitle: INSTRUCTION MANUAL HIGH INTENSITY RUNWAY LIGHT/QUARTZ (HRLQ) FAA L-862. DOCUMENT 8922 August 28, 2012 Revision S
Cooper Industries Crouse-Hinds Division Crouse-Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683-4300 Fax 860 683-4354 DOCUMENT 8922 August 28, 2012 Title: INSTRUCTION MANUAL
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationHeavy Duty Series (HDS) Installation and user guide
Heavy Duty Series (HDS) Installation and user guide HDS20-50 HDS20-100 (2x50 Watt transducers) (2x100 Watt transducers) www.shipsonic.com a brand of: delta-sistems BV Blokjesplaat 1 4465 BC Goes The Netherlands
More informationSonoSelect and SonoSafe energy meters
energy meters 03/2017 Danfoss VUIGB602 www.heating.danfoss.com 1 Note! To ensure latest version of declaration, please visit danfoss.com. 2 Danfoss Energy Meters 2017.03 VUIGB702 Contents 1. Inside the
More informationAirfield Lighting Systems & NavAids. Product Catalog
Airfield Lighting Systems & NavAids Product Catalog CORPORATE OVERVIEW Astronics DME is a wholly owned subsidiary of Astronics Corporation, a leading supplier of aviation products to the global aerospace,
More informationPOINT WIND CONE PWC FAA L-806 & L-807
Compliances: ETL Verified FAA L-806 FAA Advisory Circular 150/5345-27D ETL Verified FAA L-807 FAA Advisory Circular 150/5345-27D Registered ISO 9001:2008 Transport Canada TP312, Chapter 5 Visual Aids ICAO
More informationLow Voltage Induction Motors
Low Voltage Induction Motors Catalogue-2009/04 E TAC-C CAST IRON Frame Size 71->355 0,18-315 kw t-telectric.com Technical features TAC-C motors are designed and manufactured according to IEC34, IEC72,
More informationA-L810 Steady-Burning Red LED Obstruction Light Installation and Maintenance Manual
A-L810 Steady-Burning Red LED Obstruction Light Installation and Maintenance Manual Steady-Burning Red LED Obstruction Light FAA Type L-810 115 / 230 Vac, 50 / 60 Hz (input) A-L810 Red LED Obstruction
More informationFault Summary The following table is a summary of faults or items featured for your information
This document is an annotated sample of a report you receive. following our visit to your premises... We pride ourselves on the quality of the report and submit. this sample for your evaluation.. Report
More informationWL-100 High Intensity Aviation Obstruction Light
WL-100 High Intensity Aviation Obstruction Light Instruction Manual Rev: 1.1V Descriptions The WL-100 is a ICAO & FAA compliant Type A / B High intensity obstruction light which is used for day-time, twilight
More informationCONTINUOUS FRICTION TESTER - CFT Trailer Mounted System YAWED WHEEL. Technical Specification
CONTINUOUS FRICTION TESTER - CFT Trailer Mounted System YAWED WHEEL Technical Specification Unit 2 Iceni Court, Icknield way Letchworth Hertfordshire SG6 1TN England Tel: + 44 (0) 1462 681 699 Email :
More informationHeavy Duty Series (HDS) Installation and user guide
Heavy Duty Series (HDS) Installation and user guide HDS40-50 HDS40-100 (4x50 Watt transducers) (4x100 Watt transducers) www.shipsonic.com a brand of: delta-sistems BV Blokjesplaat 1 4465 BC Goes The Netherlands
More informationPOINT ROLLOVER LIGHTS PRL LED v4 HELIPORT INSET LIGHT
Compliances: ETL Listed to UL 1598A Marine Vessels at -40 deg C to +55 deg C, IP66 & IP67 ETL Listed to CSA C22.2 No. 137-M1981 & No. 250.0-08 Canada ETL Listed to UL 1598 at -40 deg C to +55 deg C IMO
More informationAirfield Lighting. Omnidirectional SafeLED Elevated Light (SL-TE-E, SL-TH-E) Product Description. Taxiway Edge Intermediate Holding Position
Product Description Omnidirectional SafeLED Elevated Light (SL-TE-E, SL-TH-E) Taxiway Edge Intermediate Holding Position Note: This page is blank for convenient double-sided printing. 1. INTRODUCTION The
More informationTECHNICAL DESCRIPTION GLOBE XL
TECHNICAL DESCRIPTION GLOBE XL version 2017_01 WESTERN CO. GLOBE XL PV street-lamp is composed of : - Crystalline PV module ; - MPPT Charge regulator that manages the battery charge with solar energy during
More informationMarch ApoluxLED FC. LED fixture for sports facilities with 0-10 V DC Smooth Dimming Control
March 2016 ApoluxLED FC LED fixture for sports facilities with 0-10 V DC Smooth Dimming Control 256 mm 94 mm 56 mm 123 mm 80 mm Ø 380 mm Applications The use of LEDs in sportshalls presents special challenges
More informationDirectory chapter 03 DIN Power (to 15 A) Types H, H 3, MH , MH Technical characteristics type H
Directory chapter 03 () Types H, H 3, MH 24 + 7, MH 21 + 5 Page Technical characteristics type H.................................... 03.10 Type H connectors.................... 03.11 Type H 3 connectors..................
More informationABACO MACHINES OPERATION MANUAL STONE/STEEL/GLASS/WOODS LIFTER (ASSGWL20) ABACO MACHINES (USA)
ABACO MACHINES OPERATION MANUAL STONE/STEEL/GLASS/WOODS LIFTER (ASSGWL20) ABACO MACHINES (USA) 14508 S. Garfield Ave., Paramount, CA 90723, USA Tel : 310-532-0366 Fax : 310-532-99 Email : sales@abacomachines.com
More informationHELIPORT PERIMETER LIGHT Model 1000 LED
HELIPORT PERIMETER LIGHT Model 1000 LED INSTALLATION INSTRUCTIONS AND TECHNICAL MANUAL PERIMETER LIGHT Model 1000 LED TECHNICAL MANUAL FUNCTION, DESCRIPTION and SPECIFICATION INSTALLATION INSTRUCTION and
More informationINDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice
INDUCTIVE CONDUCTIVITY SENSOR Instruction Manual Bürkert 00 Subject to technical change without notice INTRODUCTION Table of Contents. INTRODUCTION.... Symbols used.... General safety instructions....
More informationERGL-L. User Manual. 96A0376, Rev. O, 2018/10/03
ERGL-L User Manual 96A0376, Rev. O, 2018/10/03 A.0 Disclaimer / Standard Warranty CE certification The equipment listed as CE certified means that the product complies with the essential requirements
More informationSupercal 539. Compact thermal energy meter
Supercal 539 Compact thermal energy meter Application Electronic, battery-powered compact thermal energy meter intended to record heat consumption in autonomous heating systems or combined heating/cooling
More informationResistance thermometer For sanitary applications Model TR22-B, for orbital welding
Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-B, for orbital welding WIKA data sheet TE 60.23 for further approvals see page 11 Applications Sanitary applications
More informationICAN INTELLIGENT AIR FLOW DEVICE
ICAN INTELLIGENT AIR FLOW DEVICE 70-200 1 IMPORTANT INSTRUCTIONS ICAN INTELLIGENT AIR FLOW DEVICE 70-200 Content page Important instructions 1 General 2 Application / Limitation / Filters 3 Head product
More information1 Planning Information
Flight Design GmbH Rudder Centering Fork - Control Stop Replacement 1 Planning Information 1.1 Affected Aircraft Type: Model: Serial Number: Applicable Countries: CT CTLS F-08-04-09, F-08-04-10, F-08-04-11,
More informationINDUSTRIAL OL - SERIES SOLAR LED INDUSTRIAL
INDUSTRIAL OL - SERIES SOLAR LED INDUSTRIAL OL-SERIES SOLAR LED INDUSTRIAL LIGHTING CARMANAH TECHNOLOGIES OVERVIEW PRODUCTS OL2 OL4 OL8 OL10 OL10A OL32 OL810 OL2000 APPLICATIONS OBSTRUCTION RAILWAY MINING
More informationABACO GLASS LIFTER (AGL38)
ABACO MACHINES ABACO GLASS LIFTER (AGL38) ABACO MACHINES (USA) 14508 S. Garfield Ave., Paramount, CA 90723, USA Tel : 310-532-0366 Fax : 310-532-0499 Email : sales@abacomachines.com Website : www.abacomachines.com
More information2017 CATALOG East Main Street Mesa, AZ
01 2017 CATALOG 9502 East Main Street Mesa, AZ 85207 888 964.1488 480 986.1488 sales@ruralelectric.com www.ruralelectric.com 02 ABOUT US Since 1964 Rural Electric has been providing electrical contracting
More informationAirfield Lighting Product Description Solar Aviation Light AV70. Airstrip Barricade Caution Taxiway Threshold Obstruction
Product Description Solar Aviation Light AV70 Airstrip Barricade Caution Taxiway Threshold Obstruction Note: This page is blank for convenient double-sided printing. 1. INTRODUCTION Utilisation Solar Aviation
More informationTemperature Sensor MBT 3270
Data Sheet Temperature Sensor MBT 327 Features Integrated plug OEM Temperature Sensor program Versions with integrated plug or cable available Various sensor elements available (RTD,, PTC) Robust, high
More informationInstruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1
Instruction Manual ThinkTop D30 2064-0000_1 Patented Sensor System Registered Design Registered Trademark ESE02248-EN3 2014-12 Original manual Table of contents The information herein is correct at the
More informationCompact Sheet-Steel Light Fittings Series 6114
> As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in
More informationuse pulldowns to assign fixture # to arm locations: K K K 14W LED 27W LED 1 Full-Cutoff optics
Lines 2, 3 and 4 and line quantities applicable to SSx mounting only Project: Type: Qty: FIT # qty SERIES - OPTICS - MOUNTING - LIGHT ENGINE - CCT - FINISH - VOLTAGE - ACCESS.1 - ACCESS.2 1 OLML- - - -
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationPAH pumps PAH Disassembling and assembling
Service guide PAH pumps PAH 50-100 Disassembling and assembling hpp.danfoss.com Table of Contents 1. Disassembling the pump... 3 2. Inspection... 7 2.1. Port plate and thrust plate... 7 2.2. Pistons...
More informationSafeSite LED Based Signaling for Hazardous Locations
SafeSite LED Based Signaling for Hazardous Locations On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDTFSFSTBROCHURE_H Features & Benefits 5 year full performance
More informationPAH pumps PAH Disassembling and assembling
Service guide PAH pumps PAH 20-32 Disassembling and assembling hpp.danfoss.com Table of Contents 1. Disassembling the pump... 3 2. Inspection... 7 2.1. Port plate and thrust plate... 7 2.2. Pistons...
More informationThermocouples Model TC10-E, for Additional Thermowell
Electrical Temperature Measurement Thermocouples Model TC10-E, for Additional Thermowell WIKA Data Sheet TE 65.05 Applications Chemical industry Petrochemical industry Off-Shore Machine building, plant
More informationRain Command Manual. Version A03. November 8, 2001
Rain Command Manual Version A03 November 8, 2001 Dramm Corporation The RAIN COMMAND is a product of MICROFAN North America. 2000 North 18 th Street Manitowoc, WI 54220 MICROFAN North America is a joint
More informationProcess resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module
Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationCCAI, CCAIF, CCAIF..H
CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside
More informationSee «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool
echnical data sheet LHA-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control
More informationDESMI Quotation. Reference: Zapytanie ofertowe - pompa Rotan Quotation no. QUV010121_1 Date:
DESMI Quotation Quotation no. QUV010121_1 CUSTOMER DETAILS: LOTOS ASFALT SP. Z O.O. () ELBLASKA 135 80-718 GDANSK, POLAND Quotation no.: QUV010121_1 Page no. 2 INVOICE ADDRESS: LOTOS ASFALT SP. Z O.O.
More informationmanuale di istruzioni instruction manual sequenza 500 al 1^ edizione, ottobre st edition october 1996
manuale di istruzioni instruction manual 1^ edizione, ottobre 1996 1st edition october 1996 sequenza 500 al sequenza 500 al cod. 5090 cod. 5091 sequenza 500 al/s sequenza 500 al/a 305 mm 260 mm 290 mm
More informationPatented! Rotating hand. Chain guide. Hoisting Equipment Hand chain hoists. Hand chain hoist model Yalelift 360. Capacity kg.
Patented! Rotating hand chain guide Protection classification II 2 GD c IIB T4 T 125 C X, II 2 GD c IIB T3 T 145 C Chain guide High quality encapsulated ball bearings and sliding bushes for smooth and
More informationFuse switch-disconnectors
Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationCHS Controls AB Tel , Fax Section 9. Tools & Markers
Section 9 Tools & Markers Section 9 Tools & Markers The safe and efficient maintenance of the airfield is of the highest importance to ensure the airfield continues to run properly. This section covers
More information(i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:-
Revision 3 Date: 28/01/2016 Amendment to Schedule 6 for Induction Motor In the said schedule, (i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:- Effective from 1 st
More informationMT50 & MT150 Electrical Multi-turn Valve Actuators
User Manual MT50 & MT150 Electrical Multi-turn Valve Actuators Rev 4.2 EQS ID 1374 Page 1 of 25 Table of Contents 1. Introduction... 3 2. Specifications and manual operation... 4 2.1 Technical data...
More informationElectric Immersion Pumps PRT and PRA, sealless
PRT and, sealless MQUALITY MANAGE ENT Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 20 l/min Delivery head H max = 32 m Temperature range -30
More informationNotification of a Proposal to issue a Certification Memorandum. Approved Model List Changes
Notification of a Proposal to issue a Certification Memorandum Approved Model List Changes EASA Proposed CM No.: Proposed CM 21.A-E Issue 01 issued 02 October 2017 Regulatory requirement(s): 21.A.57, 21.A.61,
More informationLighting Symbols 100 KM/H
LED Technology Unrivalled lifespan of up to 100,000 hours together with low power consumption and resistance to high levels of shock and vibration make LEDs the ideal light source for emergency lighting.
More informationBEFCO. Operator s Manual BABY HOP & HOP FERTILIZER SPREADERS ACCESSORIES SIDE ROW DISCHARGE. AA4-120 (fits models Hop 209 & 212) DEFLECTOR
BEFCO Operator s Manual BABY HOP & HOP FERTILIZER SPREADERS ACCESSORIES SIDE ROW DISCHARGE AA-0 (fits models Hop 09 & ) DEFLECTOR AA-0 (fits models Baby Hop 0 & 06) 009-95 (fits models Hop 0 & 06) 009-968
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has
More informationSTANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011
Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV
More informationAtlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)
Atlas ESR Capacitance and Equivalent Series Resistance Meter Model ESR60 (Enhanced) User Guide Peak Electronic Design Limited 2004/2008 In the interests of development, information in this guide is subject
More information