ELD Series - DC Motor Drive

Size: px
Start display at page:

Download "ELD Series - DC Motor Drive"

Transcription

1 ELD Series - D Motor Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements and long life D electrical powered fans to give extended trouble free operation in mobile hydraulic applications. The compact design allows the coolers to fit most equipment and provides the highest cooling performance in heat dissipation while minimizing space required. Features Most coolers are designed with the inlet/outlet ports facing toward the back to help reduce fittings ll coolers feature a built in thermostat port 12 and 24 volt D fans Up to 47 HP cooling capacity Rated flows up to 47 gpm Motor lifetimes up to 10,000 hours vailable with internal pressure or thermal bypass Hydraulic Symbol Sizes pplications M gricultural utomotive Sizes 5-6 M M onstruction Utility General Railways Material Handling Forrestry Housing elded Steel Heat Exchanger luminum Heavy Duty ar and Plate Fan Plastic Mounting Orientation ny Orientation Maximum Pressure 230 psi (16 ar) Fluids Mineral oil to DIN Part 1 and 2 mbient Temperature 50º 104ºF (10º 40º) Maximum Oil Temperature 266ºF (130º) Standard irflow Direction ir pulled across heat exchanger Filtration ISO/DIS 4406 ode 19/16- Filtration Grade 25>75 Environmental Protection lass IP68 Standard Fan onnector MP ode INNOTIE FLUID POER

2 Model ode Model ELD = ir ooled Oil ooler with D Motor Drive Size 1.5H 2H 3H 4H 4.5H 5H 6H ELD 1.5H S F X X Modification Number (latest version always supplied) Motor Drive oltage 12 = 12 volt D 24 = 24 volt D ir Flow Direction S = Suction (standard) = lowing (consult factory) ccessories (omit) = None TS-120 = Inline Thermostat, Fixed 120º F TS-140 = Inline Thermostat, Fixed 140º F (dditional set points available - onsult factory) TS-160 = Inline Thermostat, Fixed 160º F F = Optional foot mount IT = Thermostatic bypass valve IP = Integrated pressure bypass valve Opening Temperature (IT Only) Opening Temp. losing Temp. 45 = 113 F (45 ) 131ºF (55º) 50 = 130 F (55 ) 150ºF (65º) 60 = 140 F (60 ) 158ºF (70º) Opening Pressure Drop (IT & IP Only) 2 = 2 bar (29 psi) 3 = 3 bar (45 psi) 4 = 4 bar (58 psi) (IP) Specifications Size Motor apacity (k) 12v / 24v urrent Draw (mps) 12v / 24v In-Rush urrent (@20ms) Fan Diameter (mm) / (in) Noise Level da* (1 Meter) eight (lbs.) ELD / / / / ELD / / 8 80 / / ELD / / 11 80/ / ELD / / / / ELD / / / / ELD / / / / ELD / / / / *The noise levels are only a guide as acoustic properties vary and depend on the characteristics of the room, connections, viscosity, and resonance. INNOTIE FLUID POER 9

3 ELD Series Heat Dissipation ooling capacity depending on oil flow and the temperature differential T between the oil inlet and air temperature. Heat ΔT = 72ºF (Tolerance: ± 5%) Heat Dissipation (HP) ELD-6 ELD-5 ELD-4.5 ELD-4 ELD-3 ELD-2 ELD Oil Flow [GPM] Pressure 30 cst (Tolerance: ± 5%) Pressure Drop (PSI) ELD-1.5 ELD-2 ELD-6 ELD-4 ELD-5 ELD-3 ELD Oil Flow [GPM] For other viscosities, the result must be multiplied by the K factors below K Factor hart iscosity (SSU) iscosity (cst) K Factor INNOTIE FLUID POER

4 ELD Series Size 1.5 (2X) E (2X) F (3X) D (2X) J ir Flow H (6X) øx L (2X) K D E F H J K L U X Y Z /2" NPT /16"-12 (F) 1-1/16"-12 (F) Sizes 2-4 (2X) E (2X) E (3X) D (2X) J ir Flow H (6X) ØX L (2X) K Size D E H J K L U X Y Z ELD /2" NPT Ø.39x0.55 slot 1-5/16"-12 (F) 1-5/16"-12 (F) ELD /2" NPT Ø.39x0.55 slot 1-5/16"-12 (F) 1-5/16"-12 (F) ELD /2" NPT Ø.41x0.5 slot 1-5/16"-12 (F) 1-5/16"-12 (F) are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches. INNOTIE FLUID POER 11

5 ELD Series Sizes 4.5 (2X) E (2X) J (2X) D ir Flow (4X) ØX H (2X) L K D E H J K L U X Y Z /2" NPT /8"-12 (F) 1-5/8"-12 (F) Sizes 5-6 (2X) E (2X) E (2X) E (4X) D (2X) J ir Flow H (8X) ØX L (2X) K Size D E H J K L U X Y Z ELD /2" NPT Ø.39x0.55 slot 1-5/8"-12 (F) 1-5/8"-12 (F) ELD /2" NPT Ø.39x0.71 slot 1-5/8"-12 (F) 1-5/8"-12 (F) are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches. 12 INNOTIE FLUID POER

6 ELD Series - Mounting Foot racket Sizes 2-4 / mm mm mm mm mm mm 3x ø mm mm mm mm mm mm mm mm R5 (4x) R5 (4x) mm mm mm mm mm mm are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches/mm. INNOTIE FLUID POER 13

7 ELH Series - Hydraulic Fan Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements combined with a high capacity hydraulic fan drive to give long, trouble free operation in mobile hydraulic applications. The compact design allows the coolers to fit most equipment and provides the highest cooling performance in heat dissipation while minimizing space required. Hydraulic Symbol Features ELH 2-5 coolers are designed with the inlet/outlet ports facing towards the back to help reduce fittings pplications vailable with internal pressure and temperature bypass ll units feature a built in thermostat port Up to 180 HP cooling capacity Rated flows up to 90 gpm (consult factory for higher flows) Hydraulic motor drive offers more cooling in a smaller package gricultural Offshore onstruction Railways Optional thermal speed control and pressure relief (onsult Factory) General onstruction Housing elded Steel Maximum Oil Temperature Maximum Operating Pressure Mounting Orientation Fan Rotation Heat Exchanger Fan Motor Industrial Utility luminum - Heavy Duty bar and plate Plastic luminum housing, Steel gears and shaft 266ºF (130º) 230 psi (16 bar) ll positions See arrow on housing Filtration ISO/DIS 4406 ode 19/16- Filtration grade 25>75 Maximum Outlet Side Pressure Motor 1740 psi (120 bar) Maximum Drain Pressure Motor 29 psi (2 bar) Fluid iscosity Range Motor cst. (recommended cst.) Fluid Temperature Range Motor Up to 194 F (90º) Material Handling Forestry For more information, please visit us at 14 INNOTIE FLUID POER

8 Model ode Model ELH = ir ooled Oil ooler with Hydraulic Fan Drive Size (See the heat transfer table found on page 16 to determine the proper size.) Modification Number (latest version always supplied) Hydraulic Motor Drive Displacement H6.3 = 6.3 ccm/rev (available only on ELH 2-6 and ELH 8) H14 = 14 ccm/rev H22 = 22 ccm/rev ir Flow Direction S = Suction (standard) = lowing ccessories F = Optional foot mount (sizes 2-4 only) IT = thermostatic bypass valve IP = integrated pressure bypass valve Opening Temperature (IT only) Opening Temp. losing Temp. 45 = 113 F (45 ) 131 F (55 ) 50 = 130 F (55 ) 150 F (65 ) 60 = 140 F (60 ) 158 F (70 ) Opening Pressure Drop (IT & IP only) 2 = 2 bar (29 psi) 3 = 3 bar (45 psi) 4 = 4 bar (58psi) (IP only) ELH H6.3 S IT 45-2 Specifications Size Motor Displacement (cm 3 /rev) Operating Speed Range (rpm) p of max 34 cst (psi) Motor Oil RPM (gpm) ontinuous Motor Operating Pressure (psi) Noise RPM Meter)* eight (lbs.) ELH / 14 / / / 6 / / 3625 / ELH / 14 / / / 6 / / 3625 / ELH / 14 / / / 435 / / 6 / / 3625 / ELH / 14 / / / 435 / / 6 / / 3625 / ELH / 14 / / / 1015 / / 6 / / 3625 / ELH 7 14 / / 2800 T 6 / / ELH / 14 / / / 1160 / / 6 / / 3625 / ELH 9 14 / / / / / ELH / / / / / ELH / / / / / *The noise levels are only a guide as acoustic properties vary and depend on the characteristics of the room, connections, viscosity, and resonance. INNOTIE FLUID POER 15

9 ELH Series Heat T =72ºF (tolerance ± 5%) ooling capacity depends on oil flow and the temperature differential ( T) between the oil inlet and air inlet. Sizes 2-5 Sizes ELH RPM ELH RPM ELH RPM ELH RPM Heat Dissipation [HP] ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM Heat Dissipation [HP] ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM Oil Flow [GPM] Oil Flow [GPM] Pressure 30cSt (tolerance ± 5%) Pressure differential p depending on flow rate Q and the viscosity of the oil ELH-3 35 ELH-4 Pressure Drop [PSI] ELH-2 ELH-6 ELH-5 ELH-7 ELH-8 ELH-9 ELH-10 ELH Oil Flow [GPM] For other viscosities, the result must be multiplied by the K factors below K Factor hart iscosity (SSU) iscosity (cst) K Factor INNOTIE FLUID POER

10 ELH Series Sizes 2-4 (6X) ØX (2X) M L (2X)M (2X)K (2X) H (3X)J ir Flow N (2X)G P (Motor Inlet) Q (Motor Drain) (2X) E P (Motor Outlet) (4X)Ø 0.31 (2X)D (2X)F Size 6.3cc 14cc 22cc D E F6.3cc F14cc F22cc G H J ELH ELH ELH K L M N P Q U X Y Z ELH /8''-14 7/16''-20 1/2''NPT x0.59 slot 1-5/16'' /16''-12 ELH /8''-14 7/16''-20 1/2''NPT x0.59 slot 1-5/16'' /16''-12 ELH /8''-14 7/16''-20 1/2''NPT x0.59 slot 1-5/16'' /16''-12 Size 5 (2X)M (4X)ØX (2X)H (2X)J ir Flow (2X)G N (2X)E (2X)L K (4X)ØS (2X)D (2X)F P (Motor Inlet) P (Motor Outlet) Q (Motor Drain) 6.3cc 14cc 22cc D E F6.3cc F14cc F22cc G H J K L M N P Q S U X Y Z /8''-14 7/16'' /2''NPT /8'' /8''-12 are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches. INNOTIE FLUID POER 17

11 ELH Series Sizes 6 J K H ir Flow (2X) G (4X) ØX (2X)N P (Motor Inlet) (2X ) E P (Motor Outlet) Q (Motor Drain) Z (Plugged) (2X) D (2X) F 6.3cc 14cc 22cc D E F6.3cc F14cc F22cc G H J K N P Q U X Y Z /8''-14 7/16''-20 1/2''NPT /8'' /8''-12 Sizes 7-8 (2X) J K (2X) H ir Flow (2X) G (2X) N P (Motor Inlet) (2X)E P (Motor Outlet) Q (Motor Drain) (2X)D (2X)F (4X)Ø X Size 6.3cc 14cc 22cc D E F6.3cc F14cc F22cc G H J ELH ELH K N P Q U X Y Z ELH /8''-14 7/16''-20 1/2''NPT x0.78 slot 1-5/8'' /8''-12 ELH /8''-14 7/16''-20 1/2''NPT /8'' /8''-12 are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches. 18 INNOTIE FLUID POER

12 ELH Series Sizes 9-11 (2X) J K (2X) H ir Flow (2X) G P (Motor Inlet) (2X)E P (Motor Outlet) Q (Motor Drain) Size 14cc 22cc D E F14cc F22cc G H ELH ELH ELH J K N P Q U X Z ELH /8''-14 7/16''-20 1/2''NPT x0.78 slot 1-7/8''-12 ELH /8''-14 7/16''-20 1/2''NPT /8''-12 ELH /8''-14 7/16''-20 1/2''NPT /8''-12 (2X)D (2X)F (2X) N (4X)Ø X ELH Series 2-4 Mounting Foot racket mm mm mm mm mm mm 3x ø mm mm mm mm mm mm mm mm R5 (4x) R5 (4x) mm mm mm mm mm mm are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches/mm. INNOTIE FLUID POER 19

ELH Series - Hydraulic Fan Drive

ELH Series - Hydraulic Fan Drive - Hydraulic Fan Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements combined with a high capacity hydraulic fan drive to give

More information

ELD Series - DC Motor Drive

ELD Series - DC Motor Drive ELD Series - D Motor Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements and long life D electrical powered fans to give extended

More information

Coolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications

Coolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications OK Series Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF 3-11 OKA 4-6 OKAF 4-6 OKA 8-11 OKAF 8-11 Description The OK Series cooler design uses a axial fan assembly which draws air through the cooler.

More information

Cooling Systems Air Cooled / Liquid Cooled

Cooling Systems Air Cooled / Liquid Cooled Cooling Systems Air Cooled / Liquid Cooled About HYDAC HYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributors worldwide and more than 40+ wholly owned branches.

More information

Coolers. Air Cooled / Liquid Cooled

Coolers. Air Cooled / Liquid Cooled Air Cooled / Liquid Cooled HYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributors worldwide and more than 40 wholly owned branches. Our know-how has evolved

More information

Air Cooler Mobile OK-ELD 0-6 with DC motor

Air Cooler Mobile OK-ELD 0-6 with DC motor ir ooler Mobile OK-ELD 0-6 with D motor Symbol General The OK-ELD air cooler series is designed specifically for mobile hydraulic applications where high performance and efficiency are required and physical

More information

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048 MOBILE OIL / AIR COOLERS NEW COMPACT DESIGN WITH HYDRAULIC MOTOR AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for mobile hydraulic applications where high performance

More information

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor ir Cooler Mobile C-LNH 8-1 with hydraulic motor Symbol General The C-LNH air cooler series is designed specifically for mobile hydraulic systems where high performance and efficiency are required and physical

More information

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048 COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications with both return

More information

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048 COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and

More information

MagHex Fan Controller

MagHex Fan Controller MagHex Fan ontroller 0916 ompact Programmable Temperature Sensor This combined sensor and controller is designed to mount directly to the heat exchanger. It provides accurate temperature control by cycling

More information

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048 MOBILE OIL / AIR COOLERS NEW COMPACT DESIGN WITH DC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for mobile hydraulic applications where high performance

More information

Temperature Sensors. How to Order Consult factory for pricing and lead time. Normally Open (Closed on temperature rise)

Temperature Sensors. How to Order Consult factory for pricing and lead time. Normally Open (Closed on temperature rise) Temperature Sensors 0916 Normally Open (losed on temperature rise) ontact Rating 6 MPS T 120 V 4 MPS T 240 V Voltage 0.1 to 240 volts or 12 VD 8 MPS, 24 VD 4 MPS Pressure 1,000 PSI operating Material 303

More information

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and

More information

Electronic Temperature Control & Bulb Well Assembly (AC)

Electronic Temperature Control & Bulb Well Assembly (AC) Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed

More information

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN COMPLETE OIL / AIR COOLER WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications. Typical applications include:

More information

Feed Pumps FZP / MFZP

Feed Pumps FZP / MFZP eed Pumps ZP / MZP Symbol General The feed pump from the ZP series is a vane pump for the low-pressure range with constant flow rate. Product eatures l irect drive pump no bell housing or coupling required

More information

Fluid Cooling Mobile AOHM / AOVHM Series

Fluid Cooling Mobile AOHM / AOVHM Series Fluid Cooling Mobile Series 0916 Performance Notes AO/AOVH Series with hydraulic motor Adjustable louvers (manual) High heat removal Heavy duty construction Wide flow range Heat removal up to 210,000 BTU/HR

More information

Fluid Cooling Shell & Tube B / SB Series

Fluid Cooling Shell & Tube B / SB Series Fluid ooling Shell & Tube / S Series 0916 erformance Notes Young Touchstone thermal interchange ompetitively priced 1/4" or 3/8" tubes available Water to water applications Sea water applications, O-Ring,

More information

Heat Exchanger Accessories

Heat Exchanger Accessories TEMPERTURE CONTROL - SERIES 123W May be used directly to control small electric motors etc using SINGLE phase power supply to maximum of 6 amps. lso for low volt (12 or 24) DC power supplies to maximum

More information

Modulating Water Valves and Bulb Wells

Modulating Water Valves and Bulb Wells Modulating Water Valves and ulb Wells PPLITION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature

More information

Hydraulics. VPV Vane Pumps. Whisper Pumps. Automation Technology

Hydraulics. VPV Vane Pumps. Whisper Pumps. Automation Technology Hydraulics VPV Vane Pumps Whisper Pumps Automation Technology VPV Vane Pump 1 Table of Contents Introduction 2 Benefits 2 Specifications 3 Ordering Guide 6 Performance Characteristics 9 Performance Characteristics

More information

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers

More information

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi) SV9--E - Solenoid Valve -way, -position spool type solenoid valve Up to 6 L/min (9.5 USgpm) bar ( psi) () () (P) (T) In the de-energized position all ports are closed. When solenoid '' is energized flow

More information

Fluid Cooling Brazed Plate BPSW Series

Fluid Cooling Brazed Plate BPSW Series Fluid Cooling Brazed Plate BPSW Series 0916 STAINLESS STEEL CONSTRUCTION Performance Notes Short lead time Stacked plate Stainless steel Copper brazed (nickel option) Oil to water applications High performance

More information

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated

More information

NFH Low Pressure Filters

NFH Low Pressure Filters PPLICTIONS NFH Low Pressure Filters Pressures to 360 psi Flows to 450 gpm Water Removal Capability 4 Ports HYDC NFH In-line Return Filters are designed for use on hydraulic power units, machine tools,

More information

6.3 SIZE 2. Ordering Code External Gear Pump

6.3 SIZE 2. Ordering Code External Gear Pump 6.3 SIZE 2 CONTENTS PGE12 Ordering Code 6.3.1 External Gear Pump Technical Information 6.3.2 Specifications 6.3.3 Hydraulic fluids 6.3.4 Viscosity range 6.3.5 Temperature range 6.3.6 Seals 6.3.7 Filtration

More information

Flow Control Valves. Overview. Accessories Catalog. Needle Valves. Flow Control Valves. Pressure Compensated Flow Control Valves.

Flow Control Valves. Overview. Accessories Catalog. Needle Valves. Flow Control Valves. Pressure Compensated Flow Control Valves. Overview Needle Valves DV, DVE & DVP Series (see page ) Flow Control Valves DRV & DRVP Series (see page ) Pressure Compensated Flow Control Valves SRVR Series (see page ) Check Valves RV & RVP Series (see

More information

PowrFlow PVX Vane Pumps

PowrFlow PVX Vane Pumps PowrFlow PVX Vane Pumps POWRFLOW PVX VANE PUMPS YOUR SOURCE FOR VANE PUMPS FOR THE MOST DEMANDING APPLICATIONS What Makes PowrFlow PVX Vane Pumps Your Best Buy? Continental Hydraulics PowrFlow PVX Vane

More information

AWE Track Edition Touring Edition Cat-Back Exhaust System Mustang GT. AWE website here

AWE Track Edition Touring Edition Cat-Back Exhaust System Mustang GT. AWE website here Thank you for purchasing the AWE Track Edition or Touring Edition Cat-Back Exhaust System for the 2015+ Mustang GT. For up-to-the-minute fitment information, be sure to visit the S550 Mustang GT section

More information

PROCESS & AUTOMATED VALVES

PROCESS & AUTOMATED VALVES Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline

More information

Catalog PowrFlowTM PVX Vane Pumps

Catalog PowrFlowTM PVX Vane Pumps Catalog PowrFlowTM PVX Vane Pumps Your source for vane pumps for the most demanding applications. What Makes PowrFlow PVX Vane Pumps Your Best Buy? Continental Hydraulics PowrFlow PVX Vane Pumps deliver

More information

Your Global Source for Today s Most Popular Solenoid Valves

Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International

More information

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve. Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application

More information

Oil/Air Cooler Units

Oil/Air Cooler Units COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. General description In hydraulic systems energy is transformed and transmitted. During this process, efficiency losses occur,

More information

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS PVX-11 VANE PUMPS VARIABLE DISPLACEMENT, COMPENSATED NOTE: See pages thru 14 for PVX-11 dimensions. PERFORMANCE SPECIFICATIONS Displacement (Nominal) 1.5 in 3 /rev. (25 cm 3 /rev.) Displacement (Actual)

More information

Duplex Pressure Filters

Duplex Pressure Filters Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical

More information

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2

More information

12 volt & 24 volt DC motor

12 volt & 24 volt DC motor www.aihti.com LP & LPR SERIES LP - LP - LP - MOILE IR COOLED LIQUID COOLERS 12 volt & 24 volt DC motor Mobile design. Operating temperature of F and pressure of PSI. Cools: Fluid power systems, lubrication

More information

OFFLINE SERIES GLOBAL STANDARD COOLER. p f

OFFLINE SERIES GLOBAL STANDARD COOLER. p f OFFLINE SERIES GLOBAL STANDARD COOLER Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com OIL-to-AIR COOLING SYSTEMS Product Information AKG Offline Series, based on AKG Cool-Line Series,

More information

FLOW CONTROL VALVES A5-1 PN# / / ACC

FLOW CONTROL VALVES A5-1 PN# / / ACC FLOW CONTROL VLVES Flow Control Valves The HYDC family of flow control valves permit safe, simple and repeatable control of hydraulic fluids at operating pressures to psi. The standard slotted control

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,

More information

Pressure Control Valves. General Description. Specifications. Ordering Information

Pressure Control Valves. General Description. Specifications. Ordering Information Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure

More information

High Speed Hydraulic Motors. Catalog HY /NA zm16 zm17

High Speed Hydraulic Motors. Catalog HY /NA zm16 zm17 High Speed Hydraulic Motors Catalog HY13-20-0-001/NA zm16 zm17 223 Introduction High Speed Features High Starting Torque typically 90% of running torque. Smooth Output Torque throughout the entire speed

More information

Off-line filter / cooler unit BKF

Off-line filter / cooler unit BKF FluidControl Off-line filter / cooler unit BKF In hydraulic systems oil transfers power and motion, and in drives it s a vital lubricant. Both as a power transfer medium and as a lubricant, oil is heated

More information

HIGH PRESSURE FILTERS Series HF2P

HIGH PRESSURE FILTERS Series HF2P HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,

More information

Low shear, low pulsation performance delivers superior finish quality

Low shear, low pulsation performance delivers superior finish quality TRITON 3:1 irculating Pumps TRITON 13HP 23375 & 233751 TRITON 38HP 23385 & 233816 Low shear, low pulsation performance delivers superior finish quality FETURES ND ENEFITS Low pulsation output provides

More information

High Speed Hydraulic Motors

High Speed Hydraulic Motors High Speed Hydraulic Motors Catalog HY13-20-0-001/NA C C225 Introduction High Speed Features High Starting Torque typically 90% of running torque. Smooth Output Torque throughout the entire speed range

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Feed Pumps Direct Drive Series 1.1.

Feed Pumps Direct Drive Series 1.1. 1.1. FEED PUMP SERIES FZP AND MFZP 1. GENERAL The feed pump, type FZP, is a direct drive vane pump with constant flow rate. It is available with flanged motor (MFZP) and comes with internal pressure relief

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Features MF Filters are manufactured with an aluminum head. MF, MFD, MFDS Series Spin-On Filters Choice of NPT, SAE straight thread O-ring boss, BSPP, and SAE 4-bolt flange porting to allow easy installation

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Engineering Data Pack L/4100 Series Pumps

Engineering Data Pack L/4100 Series Pumps Engineering Data Pack L/400 Series Pumps Excellence at work. Excellence in life. Table of ontents Product Overview LE Standard LE Metric 00, 0,, & 2LE Pump Mounting Dimensions 5 5LE Pump Mounting Dimensions

More information

Cooling Systems CC Series TT rail 20/30lpm

Cooling Systems CC Series TT rail 20/30lpm CC Series 20/30lpm General Data And Details The oil / air coolers of our CC series are autonomous cooling systems with an integrated circulation pump. They work as a separate cooling unit or as a ilter

More information

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION . VRIBL ISPLMNT MHNIL OMPNSTION ONTNTS PVV101 Ordering ode..1 Mechanical compensation Technical Information..2 Specifications.. Hydraulic fluids..4 Viscosity range..5 Temperature range..6 Seals..7 Filtration..8

More information

Engineering Data Pack C Series and 4300 Series Pumps

Engineering Data Pack C Series and 4300 Series Pumps Engineering Data Pack Series and 4300 Series Pumps Excellence at work. Excellence in life. Table of ontents Product Overview 3 2F Features 3 2E Features 3 2B/4310 Features 3 K2B Features 3 2FA Features

More information

HYDRAULIC MOTORS MLHH

HYDRAULIC MOTORS MLHH HYDRAULIC APPLICATION» Conveyors» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries» Mining machinery etc. CONTENTS Specification

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

Monarch D.C. Hydraulic Power Systems. Comprehensive information may be found on the page referenced below each selection category.

Monarch D.C. Hydraulic Power Systems. Comprehensive information may be found on the page referenced below each selection category. Monarch D.C. Hydraulic Power Systems MODEL M-319 Description: Pump/Motor/Reservoir/Valve Check Valve 2-Way/2-Position Normally Closed Solenoid Operated Lowering Valve Externally Adjustable Relief Valve

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

VISCOSITY RANGE GPM m 3 h PSI Bar F C SSU cst

VISCOSITY RANGE GPM m 3 h PSI Bar F C SSU cst UNIVERSL PRODUCT LINE: SERIES 724, 4724 Section 1706 Page 1706.1 Issue B TBLE OF CONTENTS Features & Benefits...2 Cutaway View & Pump Features...2 Model Number Key...3 Standard Materials of Construction...3

More information

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm Hydraulic Symbol A B Features Meets HF4 automotive standard Non-welded housing design reduces stress concentrations and prevents

More information

Series 40 Pumps Model Code Supplement Variable pumps model code

Series 40 Pumps Model Code Supplement Variable pumps model code odel Code Supplement Single pump model code Product A B C D E F G H J K L 1 2 3 N P 1 2 S T P Product series Code Description P Series 40 variable pump A Displacement 025 24.6 cm³/rev [1.50 in³/rev] 035

More information

Radial piston motor for wheel drives MCR-F

Radial piston motor for wheel drives MCR-F Radial piston motor for wheel drives MCR-F RE 15198 Edition: 02.2017 Replaces 07.2015 Frame size MCR3, MCR5, MCR10, MCR15 (for frame size 20 see MCR20-C) Displacement 160 cc to 2150 cc Differential pressure

More information

Off-Line Filter BNF. FluidControl

Off-Line Filter BNF. FluidControl FluidControl Off-Line Filter BNF In hydraulic systems oil transfers power and motion, and in drives it s a vital lubricant. Both as a power transfer medium and as a lubricant, oil is heated by friction

More information

OIL COOLERS MOBILE AIR COOLED. 12 volt & 24 volt DC motor

OIL COOLERS MOBILE AIR COOLED. 12 volt & 24 volt DC motor OF SERIES OF-4 OF-2 OF-1 OILE IR OOLED OIL OOLERS 12 volt & 24 volt D motor Reliable, tested, rugged. omputerized selection available. ustom designs to fit your needs. Operating temperature of 400 F and

More information

AKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER

AKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER KG 2009 (changes and errors expected) GLOBL STNDRD COOLER GLOBL STNDRD OIL-TO-IR COOLING SYSTEMS WITH C-MOTOR PRODUCT INFORMTION KG CooL-Line is a standard line of products from the market leader in high

More information

Whisper Pumps VPV Vane Pumps

Whisper Pumps VPV Vane Pumps Whisper Pumps VPV Vane Pumps Contents Whisper Vane Pump Catalog 3 Contents Introduction 4 Benefits 4 Specifications 5 Ordering details 8 Performance characteristics 12 VPV 16 to PSI (21 Bar) 12 VPV 25

More information

GENERAL PUMPA member of the Interpump Group

GENERAL PUMPA member of the Interpump Group FEATURES Innovative drive design eliminates need for auxiliary hydraulic drive HWB Series Hydraulic Drive - Triplex Plunger Pump HWB2512 & HWB2112 Forged brass manifold No scheduled maintenance required

More information

MEDIUM PRESSURE FILTERS

MEDIUM PRESSURE FILTERS Medium Pressure Filters 61-2999 psi Low-cost aluminum construction inline filters, provide flexibility for use in both mobile and industrial applications. Durable and light weight, these filters are ideal

More information

VALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G

VALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G VLVES POWER TRNSMISSION T E C H N I C L C T L O G Power transmission POCLIN HYDRULICS Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products.

More information

Poppet Valves Series

Poppet Valves Series Poppet Valves 750 Series ontents Section Page Introduction 750 Series Poppet Valve Pilot operated 4 /4 to / Pilot operated 5 /4 to Pilot operated 6 Pilot operated 7 /4 to / Pilot solenoid operated 8 /4

More information

W1200 SERIES HYDRAULIC PUMP

W1200 SERIES HYDRAULIC PUMP W1200 SERIES HYDRAULIC PUMP Concentric A Innovation in Hydraulics Table of Contents Description Page Number W1200 Product Specifications and Performance Information -----------------------------------------------------------------------3

More information

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES GENERAL PUMP HWB Series Hydraulic Drive Triplex Plunger Pump FEATURES INDUSTRIAL INDUSTRIAL Innovative drive design eliminates need for auxiliary hydraulic drive Forged brass manifold Built-in Pump Thermal

More information

PRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges

PRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges Technical Information General Description proportional pressure reducing valves keep a constant pressure p red on the secondary, or regulated, side, independent of pressure fluctuations on the primary

More information

W1500 SERIES HYDRAULIC PUMP

W1500 SERIES HYDRAULIC PUMP W1500 SERIES HYDRAULIC PUMP Concentric AB Innovation in Hydraulics PRESSURE (P1) 276 BAR (4000 PSI) (P2) 300 BAR (4400 PSI) SPEED 3300 RPM Min. 500 RPM at 4000 PSI (276 BAR) Continuous EFFICIENCY Overall

More information

FLUID COOLING Shell & Tube EK Series

FLUID COOLING Shell & Tube EK Series FLUID COOLING Shell & Tube Series COPPER & STEEL CONSTRUCTION Features Compact Size High Efficiency Finned Bundle Design Low Cost Optional Patented Built-in Surge-Cushion Relief Bypass 3/16 Tube Size Heat

More information

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators lectric, Hydraulic, and Pneumatic ctuators TL 1. Select Valve ody including P ode (Valve Size, v Rating, Port ode) or select Valve ssemly correct (refer to Tale 3 and Tale 3 also) less ctuator ode (XXX)

More information

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit Introduction *not included Pump with standard compensator, code: "omit" With thru shaft option for multiple pump options Swash plate type for open circuit Pump with load sensing, code: "A" Mounting style

More information

Low Pressure Filters

Low Pressure Filters MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol /80/85/160/180 MF 90/95/190/195 A A B B Features MF Filters are manufactured with an aluminum head. Choice of NPT, SAE straight

More information

HYDRAULIC MOTOR-BRAKE B/MR

HYDRAULIC MOTOR-BRAKE B/MR HYDRAULI APPLIAION onveyors Feeding mechanism of robots and manipulators Metal working machines extile machines Agriculture machines Food industries Mining machinery etc. ONENS Specification data... 22

More information

Modulating Water Valves and Bulb Wells

Modulating Water Valves and Bulb Wells Modulating Water Valves and ulb Wells PPLICTION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature

More information

Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR. Hydraulic Generator. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR. Hydraulic Generator. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators Setting the Standard in Mobile Power Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR Hydraulic Generator Manufacturing of: Vehicle Mounted Generators Hydraulic Generators P.O. Box 582 Chester,

More information

Post-Compensated Proportional Valve CV2000LS

Post-Compensated Proportional Valve CV2000LS www.nimco-controls.com Post-Compensated Proportional Valve CV2000LS Smart Solutions... for the Future Contents Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16

More information

» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries.

» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries. HYDRAULIC MH APPLICATION» Conveyors» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries» Mining machinery etc. CONTENTS Specification

More information

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground. Heat exchangers Air/Oil LAC - LAC with AC Motor for Industrial Use - Maximum cooling capacity 300 kw Heat exchangers Air/Oil LAC-X - ATEX Version. Approved for applications where there may be an explosive

More information

Series RFLD Duplex In-Line Filter

Series RFLD Duplex In-Line Filter APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.

More information

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio PNUMTI RK N PINION TUTORS dvanced torque to size ratio eatures: Pneumatic Rack and Pinion ctuators 90 ctuation for -way valves (Straight & ngle) 180 ctuation for -way (T-type) valves ctuators comply with

More information

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series General Information General Information P2 Series The newly developed variable displacement piston pumps from Parker Hannifin, designated P2, are intended for mobile applications, featuring a very compact

More information

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance DC/DCS Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance All DC/DCS and Dual Fan models available with internal pressure bypass DC Motor Driven Cooling Fans Are A Low Cost Solution

More information

Series RFL In-Line Filter

Series RFL In-Line Filter APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction

More information

MOVICONTROL. Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ.

MOVICONTROL. Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ. Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ www.movicontrol.com.br V10/V20 Series Features Balanced vane type pumps are excellent for medium- to low-pressure mobile and industrial

More information

NG06. General Size NG6 NG10 Design

NG06. General Size NG6 NG10 Design Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve

More information

VB-7000 Series 1/2 to 2 Globe Valves

VB-7000 Series 1/2 to 2 Globe Valves V-7000 Series 1/2 to 2 Globe Valves with MG350V Series SmartX ctuators schneider-electric.com 1 Product Description Schneider Electric MG350V non-spring actuators and V-7000 series two and three-way globe

More information

HYDRAULIC DISC BRAKES LB, LBS, LBV- Wet

HYDRAULIC DISC BRAKES LB, LBS, LBV- Wet HYRULI IS S LB, LBS, LBV- Wet PPLITION» Heavy uty machinery» Wheel drives» Material handling» Mining» gricultural machines» onveyors» oor openers and swing drives etc. GENERL Fluid type O O Temperature

More information

D SERIES HYDRAULIC PUMP

D SERIES HYDRAULIC PUMP uk distributor for D SERIES HYDRAULIC PUMP quality products for mechanical & fluid power jbj Techniques Limited, www.jbj.co.uk Introduction to Concentric D Series Hydraulic Pumps Concentric offers one

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A60/E Axial piston pumps type PVP variable displacement, by a full line of mechanical controls PVPL4046 PVP are variable displacement axial piston pumps for high pressure operation,

More information

Variable displacement axial piston pumps,

Variable displacement axial piston pumps, ariable displacement axial piston pumps, for open circuit DISPLACEMENTS From To 2.75 in 3 /rev (45 cm 3 /rev) 5.12 in 3 /rev (84 cm 3 /rev) MAX SPEED 3000 min -1 PRESSURE Max. continuous Max. intermittent

More information