1 ELD Series - D Motor Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements and long life D electrical powered fans to give extended trouble free operation in mobile hydraulic applications. The compact design allows the coolers to fit most equipment and provides the highest cooling performance in heat dissipation while minimizing space required. Features Most coolers are designed with the inlet/outlet ports facing toward the back to help reduce fittings ll coolers feature a built in thermostat port 12 and 24 volt D fans Up to 47 HP cooling capacity Rated flows up to 47 gpm Motor lifetimes up to 10,000 hours vailable with internal pressure or thermal bypass Hydraulic Symbol Sizes pplications M gricultural utomotive Sizes 5-6 M M onstruction Utility General Railways Material Handling Forrestry Housing elded Steel Heat Exchanger luminum Heavy Duty ar and Plate Fan Plastic Mounting Orientation ny Orientation Maximum Pressure 230 psi (16 ar) Fluids Mineral oil to DIN Part 1 and 2 mbient Temperature 50º 104ºF (10º 40º) Maximum Oil Temperature 266ºF (130º) Standard irflow Direction ir pulled across heat exchanger Filtration ISO/DIS 4406 ode 19/16- Filtration Grade 25>75 Environmental Protection lass IP68 Standard Fan onnector MP ode INNOTIE FLUID POER
2 Model ode Model ELD = ir ooled Oil ooler with D Motor Drive Size 1.5H 2H 3H 4H 4.5H 5H 6H ELD 1.5H S F X X Modification Number (latest version always supplied) Motor Drive oltage 12 = 12 volt D 24 = 24 volt D ir Flow Direction S = Suction (standard) = lowing (consult factory) ccessories (omit) = None TS-120 = Inline Thermostat, Fixed 120º F TS-140 = Inline Thermostat, Fixed 140º F (dditional set points available - onsult factory) TS-160 = Inline Thermostat, Fixed 160º F F = Optional foot mount IT = Thermostatic bypass valve IP = Integrated pressure bypass valve Opening Temperature (IT Only) Opening Temp. losing Temp. 45 = 113 F (45 ) 131ºF (55º) 50 = 130 F (55 ) 150ºF (65º) 60 = 140 F (60 ) 158ºF (70º) Opening Pressure Drop (IT & IP Only) 2 = 2 bar (29 psi) 3 = 3 bar (45 psi) 4 = 4 bar (58 psi) (IP) Specifications Size Motor apacity (k) 12v / 24v urrent Draw (mps) 12v / 24v In-Rush urrent (@20ms) Fan Diameter (mm) / (in) Noise Level da* (1 Meter) eight (lbs.) ELD / / / / ELD / / 8 80 / / ELD / / 11 80/ / ELD / / / / ELD / / / / ELD / / / / ELD / / / / *The noise levels are only a guide as acoustic properties vary and depend on the characteristics of the room, connections, viscosity, and resonance. INNOTIE FLUID POER 9
3 ELD Series Heat Dissipation ooling capacity depending on oil flow and the temperature differential T between the oil inlet and air temperature. Heat ΔT = 72ºF (Tolerance: ± 5%) Heat Dissipation (HP) ELD-6 ELD-5 ELD-4.5 ELD-4 ELD-3 ELD-2 ELD Oil Flow [GPM] Pressure 30 cst (Tolerance: ± 5%) Pressure Drop (PSI) ELD-1.5 ELD-2 ELD-6 ELD-4 ELD-5 ELD-3 ELD Oil Flow [GPM] For other viscosities, the result must be multiplied by the K factors below K Factor hart iscosity (SSU) iscosity (cst) K Factor INNOTIE FLUID POER
4 ELD Series Size 1.5 (2X) E (2X) F (3X) D (2X) J ir Flow H (6X) øx L (2X) K D E F H J K L U X Y Z /2" NPT /16"-12 (F) 1-1/16"-12 (F) Sizes 2-4 (2X) E (2X) E (3X) D (2X) J ir Flow H (6X) ØX L (2X) K Size D E H J K L U X Y Z ELD /2" NPT Ø.39x0.55 slot 1-5/16"-12 (F) 1-5/16"-12 (F) ELD /2" NPT Ø.39x0.55 slot 1-5/16"-12 (F) 1-5/16"-12 (F) ELD /2" NPT Ø.41x0.5 slot 1-5/16"-12 (F) 1-5/16"-12 (F) are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches. INNOTIE FLUID POER 11
5 ELD Series Sizes 4.5 (2X) E (2X) J (2X) D ir Flow (4X) ØX H (2X) L K D E H J K L U X Y Z /2" NPT /8"-12 (F) 1-5/8"-12 (F) Sizes 5-6 (2X) E (2X) E (2X) E (4X) D (2X) J ir Flow H (8X) ØX L (2X) K Size D E H J K L U X Y Z ELD /2" NPT Ø.39x0.55 slot 1-5/8"-12 (F) 1-5/8"-12 (F) ELD /2" NPT Ø.39x0.71 slot 1-5/8"-12 (F) 1-5/8"-12 (F) are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches. 12 INNOTIE FLUID POER
6 ELD Series - Mounting Foot racket Sizes 2-4 / mm mm mm mm mm mm 3x ø mm mm mm mm mm mm mm mm R5 (4x) R5 (4x) mm mm mm mm mm mm are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches/mm. INNOTIE FLUID POER 13
7 ELH Series - Hydraulic Fan Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements combined with a high capacity hydraulic fan drive to give long, trouble free operation in mobile hydraulic applications. The compact design allows the coolers to fit most equipment and provides the highest cooling performance in heat dissipation while minimizing space required. Hydraulic Symbol Features ELH 2-5 coolers are designed with the inlet/outlet ports facing towards the back to help reduce fittings pplications vailable with internal pressure and temperature bypass ll units feature a built in thermostat port Up to 180 HP cooling capacity Rated flows up to 90 gpm (consult factory for higher flows) Hydraulic motor drive offers more cooling in a smaller package gricultural Offshore onstruction Railways Optional thermal speed control and pressure relief (onsult Factory) General onstruction Housing elded Steel Maximum Oil Temperature Maximum Operating Pressure Mounting Orientation Fan Rotation Heat Exchanger Fan Motor Industrial Utility luminum - Heavy Duty bar and plate Plastic luminum housing, Steel gears and shaft 266ºF (130º) 230 psi (16 bar) ll positions See arrow on housing Filtration ISO/DIS 4406 ode 19/16- Filtration grade 25>75 Maximum Outlet Side Pressure Motor 1740 psi (120 bar) Maximum Drain Pressure Motor 29 psi (2 bar) Fluid iscosity Range Motor cst. (recommended cst.) Fluid Temperature Range Motor Up to 194 F (90º) Material Handling Forestry For more information, please visit us at 14 INNOTIE FLUID POER
8 Model ode Model ELH = ir ooled Oil ooler with Hydraulic Fan Drive Size (See the heat transfer table found on page 16 to determine the proper size.) Modification Number (latest version always supplied) Hydraulic Motor Drive Displacement H6.3 = 6.3 ccm/rev (available only on ELH 2-6 and ELH 8) H14 = 14 ccm/rev H22 = 22 ccm/rev ir Flow Direction S = Suction (standard) = lowing ccessories F = Optional foot mount (sizes 2-4 only) IT = thermostatic bypass valve IP = integrated pressure bypass valve Opening Temperature (IT only) Opening Temp. losing Temp. 45 = 113 F (45 ) 131 F (55 ) 50 = 130 F (55 ) 150 F (65 ) 60 = 140 F (60 ) 158 F (70 ) Opening Pressure Drop (IT & IP only) 2 = 2 bar (29 psi) 3 = 3 bar (45 psi) 4 = 4 bar (58psi) (IP only) ELH H6.3 S IT 45-2 Specifications Size Motor Displacement (cm 3 /rev) Operating Speed Range (rpm) p of max 34 cst (psi) Motor Oil RPM (gpm) ontinuous Motor Operating Pressure (psi) Noise RPM Meter)* eight (lbs.) ELH / 14 / / / 6 / / 3625 / ELH / 14 / / / 6 / / 3625 / ELH / 14 / / / 435 / / 6 / / 3625 / ELH / 14 / / / 435 / / 6 / / 3625 / ELH / 14 / / / 1015 / / 6 / / 3625 / ELH 7 14 / / 2800 T 6 / / ELH / 14 / / / 1160 / / 6 / / 3625 / ELH 9 14 / / / / / ELH / / / / / ELH / / / / / *The noise levels are only a guide as acoustic properties vary and depend on the characteristics of the room, connections, viscosity, and resonance. INNOTIE FLUID POER 15
9 ELH Series Heat T =72ºF (tolerance ± 5%) ooling capacity depends on oil flow and the temperature differential ( T) between the oil inlet and air inlet. Sizes 2-5 Sizes ELH RPM ELH RPM ELH RPM ELH RPM Heat Dissipation [HP] ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM Heat Dissipation [HP] ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM ELH RPM Oil Flow [GPM] Oil Flow [GPM] Pressure 30cSt (tolerance ± 5%) Pressure differential p depending on flow rate Q and the viscosity of the oil ELH-3 35 ELH-4 Pressure Drop [PSI] ELH-2 ELH-6 ELH-5 ELH-7 ELH-8 ELH-9 ELH-10 ELH Oil Flow [GPM] For other viscosities, the result must be multiplied by the K factors below K Factor hart iscosity (SSU) iscosity (cst) K Factor INNOTIE FLUID POER
10 ELH Series Sizes 2-4 (6X) ØX (2X) M L (2X)M (2X)K (2X) H (3X)J ir Flow N (2X)G P (Motor Inlet) Q (Motor Drain) (2X) E P (Motor Outlet) (4X)Ø 0.31 (2X)D (2X)F Size 6.3cc 14cc 22cc D E F6.3cc F14cc F22cc G H J ELH ELH ELH K L M N P Q U X Y Z ELH /8''-14 7/16''-20 1/2''NPT x0.59 slot 1-5/16'' /16''-12 ELH /8''-14 7/16''-20 1/2''NPT x0.59 slot 1-5/16'' /16''-12 ELH /8''-14 7/16''-20 1/2''NPT x0.59 slot 1-5/16'' /16''-12 Size 5 (2X)M (4X)ØX (2X)H (2X)J ir Flow (2X)G N (2X)E (2X)L K (4X)ØS (2X)D (2X)F P (Motor Inlet) P (Motor Outlet) Q (Motor Drain) 6.3cc 14cc 22cc D E F6.3cc F14cc F22cc G H J K L M N P Q S U X Y Z /8''-14 7/16'' /2''NPT /8'' /8''-12 are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches. INNOTIE FLUID POER 17
11 ELH Series Sizes 6 J K H ir Flow (2X) G (4X) ØX (2X)N P (Motor Inlet) (2X ) E P (Motor Outlet) Q (Motor Drain) Z (Plugged) (2X) D (2X) F 6.3cc 14cc 22cc D E F6.3cc F14cc F22cc G H J K N P Q U X Y Z /8''-14 7/16''-20 1/2''NPT /8'' /8''-12 Sizes 7-8 (2X) J K (2X) H ir Flow (2X) G (2X) N P (Motor Inlet) (2X)E P (Motor Outlet) Q (Motor Drain) (2X)D (2X)F (4X)Ø X Size 6.3cc 14cc 22cc D E F6.3cc F14cc F22cc G H J ELH ELH K N P Q U X Y Z ELH /8''-14 7/16''-20 1/2''NPT x0.78 slot 1-5/8'' /8''-12 ELH /8''-14 7/16''-20 1/2''NPT /8'' /8''-12 are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches. 18 INNOTIE FLUID POER
12 ELH Series Sizes 9-11 (2X) J K (2X) H ir Flow (2X) G P (Motor Inlet) (2X)E P (Motor Outlet) Q (Motor Drain) Size 14cc 22cc D E F14cc F22cc G H ELH ELH ELH J K N P Q U X Z ELH /8''-14 7/16''-20 1/2''NPT x0.78 slot 1-7/8''-12 ELH /8''-14 7/16''-20 1/2''NPT /8''-12 ELH /8''-14 7/16''-20 1/2''NPT /8''-12 (2X)D (2X)F (2X) N (4X)Ø X ELH Series 2-4 Mounting Foot racket mm mm mm mm mm mm 3x ø mm mm mm mm mm mm mm mm R5 (4x) R5 (4x) mm mm mm mm mm mm are for general information only, all critical dimensions should be verified by requesting a certified print. are in inches/mm. INNOTIE FLUID POER 19
ELH Series - Hydraulic Fan Drive
- Hydraulic Fan Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements combined with a high capacity hydraulic fan drive to give
More informationELD Series - DC Motor Drive
ELD Series - D Motor Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements and long life D electrical powered fans to give extended
More informationCoolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications
OK Series Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF 3-11 OKA 4-6 OKAF 4-6 OKA 8-11 OKAF 8-11 Description The OK Series cooler design uses a axial fan assembly which draws air through the cooler.
More informationCooling Systems Air Cooled / Liquid Cooled
Cooling Systems Air Cooled / Liquid Cooled About HYDAC HYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributors worldwide and more than 40+ wholly owned branches.
More informationCoolers. Air Cooled / Liquid Cooled
Air Cooled / Liquid Cooled HYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributors worldwide and more than 40 wholly owned branches. Our know-how has evolved
More informationAir Cooler Mobile OK-ELD 0-6 with DC motor
ir ooler Mobile OK-ELD 0-6 with D motor Symbol General The OK-ELD air cooler series is designed specifically for mobile hydraulic applications where high performance and efficiency are required and physical
More informationOil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048
MOBILE OIL / AIR COOLERS NEW COMPACT DESIGN WITH HYDRAULIC MOTOR AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for mobile hydraulic applications where high performance
More informationAir Cooler Mobile AC-LNH 8-14 with hydraulic motor
ir Cooler Mobile C-LNH 8-1 with hydraulic motor Symbol General The C-LNH air cooler series is designed specifically for mobile hydraulic systems where high performance and efficiency are required and physical
More informationOil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048
COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications with both return
More informationOil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048
COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and
More informationMagHex Fan Controller
MagHex Fan ontroller 0916 ompact Programmable Temperature Sensor This combined sensor and controller is designed to mount directly to the heat exchanger. It provides accurate temperature control by cycling
More informationOil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048
MOBILE OIL / AIR COOLERS NEW COMPACT DESIGN WITH DC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for mobile hydraulic applications where high performance
More informationTemperature Sensors. How to Order Consult factory for pricing and lead time. Normally Open (Closed on temperature rise)
Temperature Sensors 0916 Normally Open (losed on temperature rise) ontact Rating 6 MPS T 120 V 4 MPS T 240 V Voltage 0.1 to 240 volts or 12 VD 8 MPS, 24 VD 4 MPS Pressure 1,000 PSI operating Material 303
More informationOil/Air Cooler Units. Compact application with AC Motor OK-ELC Type
COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and
More informationElectronic Temperature Control & Bulb Well Assembly (AC)
Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed
More informationOil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN
COMPLETE OIL / AIR COOLER WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications. Typical applications include:
More informationFeed Pumps FZP / MFZP
eed Pumps ZP / MZP Symbol General The feed pump from the ZP series is a vane pump for the low-pressure range with constant flow rate. Product eatures l irect drive pump no bell housing or coupling required
More informationFluid Cooling Mobile AOHM / AOVHM Series
Fluid Cooling Mobile Series 0916 Performance Notes AO/AOVH Series with hydraulic motor Adjustable louvers (manual) High heat removal Heavy duty construction Wide flow range Heat removal up to 210,000 BTU/HR
More informationFluid Cooling Shell & Tube B / SB Series
Fluid ooling Shell & Tube / S Series 0916 erformance Notes Young Touchstone thermal interchange ompetitively priced 1/4" or 3/8" tubes available Water to water applications Sea water applications, O-Ring,
More informationHeat Exchanger Accessories
TEMPERTURE CONTROL - SERIES 123W May be used directly to control small electric motors etc using SINGLE phase power supply to maximum of 6 amps. lso for low volt (12 or 24) DC power supplies to maximum
More informationModulating Water Valves and Bulb Wells
Modulating Water Valves and ulb Wells PPLITION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature
More informationHydraulics. VPV Vane Pumps. Whisper Pumps. Automation Technology
Hydraulics VPV Vane Pumps Whisper Pumps Automation Technology VPV Vane Pump 1 Table of Contents Introduction 2 Benefits 2 Specifications 3 Ordering Guide 6 Performance Characteristics 9 Performance Characteristics
More informationAir Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11
Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers
More informationSV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)
SV9--E - Solenoid Valve -way, -position spool type solenoid valve Up to 6 L/min (9.5 USgpm) bar ( psi) () () (P) (T) In the de-energized position all ports are closed. When solenoid '' is energized flow
More informationFluid Cooling Brazed Plate BPSW Series
Fluid Cooling Brazed Plate BPSW Series 0916 STAINLESS STEEL CONSTRUCTION Performance Notes Short lead time Stacked plate Stainless steel Copper brazed (nickel option) Oil to water applications High performance
More informationPressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features
Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated
More informationNFH Low Pressure Filters
PPLICTIONS NFH Low Pressure Filters Pressures to 360 psi Flows to 450 gpm Water Removal Capability 4 Ports HYDC NFH In-line Return Filters are designed for use on hydraulic power units, machine tools,
More information6.3 SIZE 2. Ordering Code External Gear Pump
6.3 SIZE 2 CONTENTS PGE12 Ordering Code 6.3.1 External Gear Pump Technical Information 6.3.2 Specifications 6.3.3 Hydraulic fluids 6.3.4 Viscosity range 6.3.5 Temperature range 6.3.6 Seals 6.3.7 Filtration
More informationFlow Control Valves. Overview. Accessories Catalog. Needle Valves. Flow Control Valves. Pressure Compensated Flow Control Valves.
Overview Needle Valves DV, DVE & DVP Series (see page ) Flow Control Valves DRV & DRVP Series (see page ) Pressure Compensated Flow Control Valves SRVR Series (see page ) Check Valves RV & RVP Series (see
More informationPowrFlow PVX Vane Pumps
PowrFlow PVX Vane Pumps POWRFLOW PVX VANE PUMPS YOUR SOURCE FOR VANE PUMPS FOR THE MOST DEMANDING APPLICATIONS What Makes PowrFlow PVX Vane Pumps Your Best Buy? Continental Hydraulics PowrFlow PVX Vane
More informationAWE Track Edition Touring Edition Cat-Back Exhaust System Mustang GT. AWE website here
Thank you for purchasing the AWE Track Edition or Touring Edition Cat-Back Exhaust System for the 2015+ Mustang GT. For up-to-the-minute fitment information, be sure to visit the S550 Mustang GT section
More informationPROCESS & AUTOMATED VALVES
Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline
More informationCatalog PowrFlowTM PVX Vane Pumps
Catalog PowrFlowTM PVX Vane Pumps Your source for vane pumps for the most demanding applications. What Makes PowrFlow PVX Vane Pumps Your Best Buy? Continental Hydraulics PowrFlow PVX Vane Pumps deliver
More informationYour Global Source for Today s Most Popular Solenoid Valves
lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International
More informationNG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.
Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application
More informationOil/Air Cooler Units
COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. General description In hydraulic systems energy is transformed and transmitted. During this process, efficiency losses occur,
More informationPVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS
PVX-11 VANE PUMPS VARIABLE DISPLACEMENT, COMPENSATED NOTE: See pages thru 14 for PVX-11 dimensions. PERFORMANCE SPECIFICATIONS Displacement (Nominal) 1.5 in 3 /rev. (25 cm 3 /rev.) Displacement (Actual)
More informationDuplex Pressure Filters
Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical
More informationW94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection
Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2
More information12 volt & 24 volt DC motor
www.aihti.com LP & LPR SERIES LP - LP - LP - MOILE IR COOLED LIQUID COOLERS 12 volt & 24 volt DC motor Mobile design. Operating temperature of F and pressure of PSI. Cools: Fluid power systems, lubrication
More informationOFFLINE SERIES GLOBAL STANDARD COOLER. p f
OFFLINE SERIES GLOBAL STANDARD COOLER Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com OIL-to-AIR COOLING SYSTEMS Product Information AKG Offline Series, based on AKG Cool-Line Series,
More informationFLOW CONTROL VALVES A5-1 PN# / / ACC
FLOW CONTROL VLVES Flow Control Valves The HYDC family of flow control valves permit safe, simple and repeatable control of hydraulic fluids at operating pressures to psi. The standard slotted control
More informationSolenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.
Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid
More informationHIGH PRESSURE FILTERS
HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
More informationPressure Control Valves. General Description. Specifications. Ordering Information
Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure
More informationHigh Speed Hydraulic Motors. Catalog HY /NA zm16 zm17
High Speed Hydraulic Motors Catalog HY13-20-0-001/NA zm16 zm17 223 Introduction High Speed Features High Starting Torque typically 90% of running torque. Smooth Output Torque throughout the entire speed
More informationOff-line filter / cooler unit BKF
FluidControl Off-line filter / cooler unit BKF In hydraulic systems oil transfers power and motion, and in drives it s a vital lubricant. Both as a power transfer medium and as a lubricant, oil is heated
More informationHIGH PRESSURE FILTERS Series HF2P
HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,
More informationLow shear, low pulsation performance delivers superior finish quality
TRITON 3:1 irculating Pumps TRITON 13HP 23375 & 233751 TRITON 38HP 23385 & 233816 Low shear, low pulsation performance delivers superior finish quality FETURES ND ENEFITS Low pulsation output provides
More informationHigh Speed Hydraulic Motors
High Speed Hydraulic Motors Catalog HY13-20-0-001/NA C C225 Introduction High Speed Features High Starting Torque typically 90% of running torque. Smooth Output Torque throughout the entire speed range
More informationPilot Operated Pressure Relief Valve Series R5V (Denison)
Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps
More informationFeed Pumps Direct Drive Series 1.1.
1.1. FEED PUMP SERIES FZP AND MFZP 1. GENERAL The feed pump, type FZP, is a direct drive vane pump with constant flow rate. It is available with flanged motor (MFZP) and comes with internal pressure relief
More informationCourtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)
Features MF Filters are manufactured with an aluminum head. MF, MFD, MFDS Series Spin-On Filters Choice of NPT, SAE straight thread O-ring boss, BSPP, and SAE 4-bolt flange porting to allow easy installation
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More informationEngineering Data Pack L/4100 Series Pumps
Engineering Data Pack L/400 Series Pumps Excellence at work. Excellence in life. Table of ontents Product Overview LE Standard LE Metric 00, 0,, & 2LE Pump Mounting Dimensions 5 5LE Pump Mounting Dimensions
More informationCooling Systems CC Series TT rail 20/30lpm
CC Series 20/30lpm General Data And Details The oil / air coolers of our CC series are autonomous cooling systems with an integrated circulation pump. They work as a separate cooling unit or as a ilter
More information3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION
. VRIBL ISPLMNT MHNIL OMPNSTION ONTNTS PVV101 Ordering ode..1 Mechanical compensation Technical Information..2 Specifications.. Hydraulic fluids..4 Viscosity range..5 Temperature range..6 Seals..7 Filtration..8
More informationEngineering Data Pack C Series and 4300 Series Pumps
Engineering Data Pack Series and 4300 Series Pumps Excellence at work. Excellence in life. Table of ontents Product Overview 3 2F Features 3 2E Features 3 2B/4310 Features 3 K2B Features 3 2FA Features
More informationHYDRAULIC MOTORS MLHH
HYDRAULIC APPLICATION» Conveyors» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries» Mining machinery etc. CONTENTS Specification
More informationFRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
More informationMonarch D.C. Hydraulic Power Systems. Comprehensive information may be found on the page referenced below each selection category.
Monarch D.C. Hydraulic Power Systems MODEL M-319 Description: Pump/Motor/Reservoir/Valve Check Valve 2-Way/2-Position Normally Closed Solenoid Operated Lowering Valve Externally Adjustable Relief Valve
More informationSolenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)
Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM
More informationVISCOSITY RANGE GPM m 3 h PSI Bar F C SSU cst
UNIVERSL PRODUCT LINE: SERIES 724, 4724 Section 1706 Page 1706.1 Issue B TBLE OF CONTENTS Features & Benefits...2 Cutaway View & Pump Features...2 Model Number Key...3 Standard Materials of Construction...3
More informationHIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm
HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm Hydraulic Symbol A B Features Meets HF4 automotive standard Non-welded housing design reduces stress concentrations and prevents
More informationSeries 40 Pumps Model Code Supplement Variable pumps model code
odel Code Supplement Single pump model code Product A B C D E F G H J K L 1 2 3 N P 1 2 S T P Product series Code Description P Series 40 variable pump A Displacement 025 24.6 cm³/rev [1.50 in³/rev] 035
More informationRadial piston motor for wheel drives MCR-F
Radial piston motor for wheel drives MCR-F RE 15198 Edition: 02.2017 Replaces 07.2015 Frame size MCR3, MCR5, MCR10, MCR15 (for frame size 20 see MCR20-C) Displacement 160 cc to 2150 cc Differential pressure
More informationOff-Line Filter BNF. FluidControl
FluidControl Off-Line Filter BNF In hydraulic systems oil transfers power and motion, and in drives it s a vital lubricant. Both as a power transfer medium and as a lubricant, oil is heated by friction
More informationOIL COOLERS MOBILE AIR COOLED. 12 volt & 24 volt DC motor
OF SERIES OF-4 OF-2 OF-1 OILE IR OOLED OIL OOLERS 12 volt & 24 volt D motor Reliable, tested, rugged. omputerized selection available. ustom designs to fit your needs. Operating temperature of 400 F and
More informationAKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER
KG 2009 (changes and errors expected) GLOBL STNDRD COOLER GLOBL STNDRD OIL-TO-IR COOLING SYSTEMS WITH C-MOTOR PRODUCT INFORMTION KG CooL-Line is a standard line of products from the market leader in high
More informationWhisper Pumps VPV Vane Pumps
Whisper Pumps VPV Vane Pumps Contents Whisper Vane Pump Catalog 3 Contents Introduction 4 Benefits 4 Specifications 5 Ordering details 8 Performance characteristics 12 VPV 16 to PSI (21 Bar) 12 VPV 25
More informationGENERAL PUMPA member of the Interpump Group
FEATURES Innovative drive design eliminates need for auxiliary hydraulic drive HWB Series Hydraulic Drive - Triplex Plunger Pump HWB2512 & HWB2112 Forged brass manifold No scheduled maintenance required
More informationMEDIUM PRESSURE FILTERS
Medium Pressure Filters 61-2999 psi Low-cost aluminum construction inline filters, provide flexibility for use in both mobile and industrial applications. Durable and light weight, these filters are ideal
More informationVALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G
VLVES POWER TRNSMISSION T E C H N I C L C T L O G Power transmission POCLIN HYDRULICS Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products.
More informationPoppet Valves Series
Poppet Valves 750 Series ontents Section Page Introduction 750 Series Poppet Valve Pilot operated 4 /4 to / Pilot operated 5 /4 to Pilot operated 6 Pilot operated 7 /4 to / Pilot solenoid operated 8 /4
More informationW1200 SERIES HYDRAULIC PUMP
W1200 SERIES HYDRAULIC PUMP Concentric A Innovation in Hydraulics Table of Contents Description Page Number W1200 Product Specifications and Performance Information -----------------------------------------------------------------------3
More informationHWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES
GENERAL PUMP HWB Series Hydraulic Drive Triplex Plunger Pump FEATURES INDUSTRIAL INDUSTRIAL Innovative drive design eliminates need for auxiliary hydraulic drive Forged brass manifold Built-in Pump Thermal
More informationPRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges
Technical Information General Description proportional pressure reducing valves keep a constant pressure p red on the secondary, or regulated, side, independent of pressure fluctuations on the primary
More informationW1500 SERIES HYDRAULIC PUMP
W1500 SERIES HYDRAULIC PUMP Concentric AB Innovation in Hydraulics PRESSURE (P1) 276 BAR (4000 PSI) (P2) 300 BAR (4400 PSI) SPEED 3300 RPM Min. 500 RPM at 4000 PSI (276 BAR) Continuous EFFICIENCY Overall
More informationFLUID COOLING Shell & Tube EK Series
FLUID COOLING Shell & Tube Series COPPER & STEEL CONSTRUCTION Features Compact Size High Efficiency Finned Bundle Design Low Cost Optional Patented Built-in Surge-Cushion Relief Bypass 3/16 Tube Size Heat
More information3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators
lectric, Hydraulic, and Pneumatic ctuators TL 1. Select Valve ody including P ode (Valve Size, v Rating, Port ode) or select Valve ssemly correct (refer to Tale 3 and Tale 3 also) less ctuator ode (XXX)
More informationHydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit
Introduction *not included Pump with standard compensator, code: "omit" With thru shaft option for multiple pump options Swash plate type for open circuit Pump with load sensing, code: "A" Mounting style
More informationLow Pressure Filters
MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol /80/85/160/180 MF 90/95/190/195 A A B B Features MF Filters are manufactured with an aluminum head. Choice of NPT, SAE straight
More informationHYDRAULIC MOTOR-BRAKE B/MR
HYDRAULI APPLIAION onveyors Feeding mechanism of robots and manipulators Metal working machines extile machines Agriculture machines Food industries Mining machinery etc. ONENS Specification data... 22
More informationModulating Water Valves and Bulb Wells
Modulating Water Valves and ulb Wells PPLICTION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature
More informationInstruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR. Hydraulic Generator. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators
Setting the Standard in Mobile Power Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR Hydraulic Generator Manufacturing of: Vehicle Mounted Generators Hydraulic Generators P.O. Box 582 Chester,
More informationPost-Compensated Proportional Valve CV2000LS
www.nimco-controls.com Post-Compensated Proportional Valve CV2000LS Smart Solutions... for the Future Contents Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16
More information» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries.
HYDRAULIC MH APPLICATION» Conveyors» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries» Mining machinery etc. CONTENTS Specification
More informationHEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.
Heat exchangers Air/Oil LAC - LAC with AC Motor for Industrial Use - Maximum cooling capacity 300 kw Heat exchangers Air/Oil LAC-X - ATEX Version. Approved for applications where there may be an explosive
More informationSeries RFLD Duplex In-Line Filter
APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.
More informationPNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio
PNUMTI RK N PINION TUTORS dvanced torque to size ratio eatures: Pneumatic Rack and Pinion ctuators 90 ctuation for -way valves (Straight & ngle) 180 ctuation for -way (T-type) valves ctuators comply with
More informationVariable Displacement Piston Pumps Series P2/P3. General Information. P3 Series
General Information General Information P2 Series The newly developed variable displacement piston pumps from Parker Hannifin, designated P2, are intended for mobile applications, featuring a very compact
More informationOil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance
DC/DCS Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance All DC/DCS and Dual Fan models available with internal pressure bypass DC Motor Driven Cooling Fans Are A Low Cost Solution
More informationSeries RFL In-Line Filter
APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction
More informationMOVICONTROL. Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ.
Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ www.movicontrol.com.br V10/V20 Series Features Balanced vane type pumps are excellent for medium- to low-pressure mobile and industrial
More informationNG06. General Size NG6 NG10 Design
Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve
More informationVB-7000 Series 1/2 to 2 Globe Valves
V-7000 Series 1/2 to 2 Globe Valves with MG350V Series SmartX ctuators schneider-electric.com 1 Product Description Schneider Electric MG350V non-spring actuators and V-7000 series two and three-way globe
More informationHYDRAULIC DISC BRAKES LB, LBS, LBV- Wet
HYRULI IS S LB, LBS, LBV- Wet PPLITION» Heavy uty machinery» Wheel drives» Material handling» Mining» gricultural machines» onveyors» oor openers and swing drives etc. GENERL Fluid type O O Temperature
More informationD SERIES HYDRAULIC PUMP
uk distributor for D SERIES HYDRAULIC PUMP quality products for mechanical & fluid power jbj Techniques Limited, www.jbj.co.uk Introduction to Concentric D Series Hydraulic Pumps Concentric offers one
More informationAxial piston pumps type PVPC variable displacement, by a full line of mechanical controls
www.atos.com Table A60/E Axial piston pumps type PVP variable displacement, by a full line of mechanical controls PVPL4046 PVP are variable displacement axial piston pumps for high pressure operation,
More informationVariable displacement axial piston pumps,
ariable displacement axial piston pumps, for open circuit DISPLACEMENTS From To 2.75 in 3 /rev (45 cm 3 /rev) 5.12 in 3 /rev (84 cm 3 /rev) MAX SPEED 3000 min -1 PRESSURE Max. continuous Max. intermittent