your and attach spreadsheet of 23 December 2003; and

Size: px
Start display at page:

Download "your and attach spreadsheet of 23 December 2003; and"

Transcription

1 s Science and Engineering 14 Julius Avenue, Riverside Corporate Park North Ryde NSW 2113 PO Box 310, North Ryde NSW 2113, Australia Telephone: (02) Facsimile: (02) ABN Our ref: /3909 Hilti ( Aust) Pty Ltd 1G Homebush Bay Drive RHODES NSW 2138 Attention: Mr Samuel Schmidt, LIKELY FIRE PERFORMANCE OF CP 643-N FIRESTOP JACKETS AND CP 648-S AND CP 648-E FIRESTOP WRAPS IN CONJUNCTION WITH VARIOUS PLASTIC PIPE SYSTEMS INSTALLED INTO WALL SYSTEMS Assessment Number Your of 9 July INTRODUCTION We have re-examined the information referenced by you on the likely performance of your collar systems and wrap systems when incorporating plastic pipes and tested in accordance with AS The information included our test report numbered FSV 1025 for the full-scale fire-resistance test conducted on a framed wall system incorporating various pipe penetrations protected by CP 643-N FIrestop jackets and CP 648-E Firestop wraps tested on 18 December 2003; our test report numbered FSH 1028 for the full-scale fire-resistance test conducted on a 150-mm thick concrete slab incorporating various pipe penetrations protected by CP 643-N FIrestop jackets and CP 648-E Firestop wraps tested on 10 January 2004; Warrington Fire Research test report numbered /A for a full-scale fire-resistance test on various wall penetration systems conducted on 13 March 2003; Warrington Fire Research test report numbered /A for a full-scale fire-resistance test on various wall penetration systems conduced on 20 March 2003; Warrington Fire Research test report numbered /A for a full-scale fire-resistance test on various floor penetration systems conduced on 1 May 2003; your and attach spreadsheet of 23 December 2003; and AS and AS We have retained these documents. CLAYTON HIGHETT LINDFIELD NORTH RYDE QUEENSLAND CENTRE FOR ADVANCED TECHNOLOGIES TIDBINBILLA YARRALUMLA

2 Page 2 of 13 pages ANALYSIS Warrington Fire Research test reports numbered /A and /A On 13 and 20 March 2003 Warrington Fire Research UK conducted full-scale fireresistance tests on nineteen penetration systems incorporating your variously sized CP 643-N Firestop jackets protecting plastic pipes penetrating lightweight concrete block walls. The testing was conducted using the heating conditions specified in BS EN :1999 in conjunction with additional guidelines taken from pren :2002 and the performance criteria of BS 476 Part 20:1987. A summary of the test installation is tabulated below. Wall Wall Specimen Designation PE CP /1.5 N E PVC CP /1.5 N F PVC CP /1.5 N G ABS CP /4 N H PE CP /6 N I PE CP /4 N J PVC CP /4 N K PE CP /4 N L ABS CP /6 N M PE CP /6 N Q PVC CP /6 N R PVC CP /6 N S PVC CP /6 N A ABS CP /4 N B PVC CP /1.5 N C PE CP /6 N H PE CP /4 N I PVC CP /6 N O PVC CP /4 N P The test results can thus be summarised. Specimen Integrity (minutes) Insulation (minutes) Equivalent E /240/240 F /240/240 G /240/240 H /240/240 I /240/240 J /240/240 K /240/240 L /240/240 M /120/120 Q /240/240 R /240/240 S /240/240 A /90/90

3 Page 3 of 13 pages Specimen Integrity (minutes) Insulation (minutes) Equivalent B /180/120 C /180/180 H /180/180 I /180/180 O /180/180 P /180/180 Warrington Fire Research test report numbered /A On 1 May 2003 Warrington Fire Research UK conducted a full-scale fire-resistance test on nineteen penetration systems incorporating your variously sized CP 643-N collars protecting plastic pipes penetrating an aerated concrete floor slab. The testing was conducted using the heating conditions specified in BS EN :1999 in conjunction with additional guidelines taken from pren :2002 and the performance criteria of BS 476 Part 20:1987. A summary of the test installation is tabulated below. Wall Floor Specimen Designation PE CP /4 N M ABS CP /4 N N ABS CP /6 N O PVC CP /6 N P PVC CP /4 N Q PVC CP /1.5 N R PVC CP /1.5 N S PE CP /6 N T PE CP /6 N U PE CP /4 N V PE CP /1.5 N W PE CP /1.5 N X ABS CP /6 N Y The test results can thus be summarised. Specimen Integrity (minutes) Insulation (minutes) Equivalent M /240/240 N /180/180 O /240/240 P /180/180 Q /240/240 R /240/240 S /240/240 T /240/240 U /60/60 V /240/240 W /240/240 X /240/240 Y /240/240

4 Page 4 of 13 pages CSIRO Fire-resistance test report numbered FSV 1025 Subsequent to this, on 18 December 2003, this Division conducted a full-scale fireresistance test in accordance with AS and AS on a plasterboard-lined framed wall system incorporating eighteen pipe penetrations. The systems are summarised in the table below. All of the pipes penetrated into the furnace by 100 mm and extended out by at least 2000 mm on the unexposed face of the wall. The pipes were supported at points 500 mm and 1500 mm from the unexposed face of the wall. Wall Nom.Wall Width / Protection Specimen Designation PVC CP /1.5 N 1 PVC CP /2 N 2 PVC CP /2.5 N 3 PVC CP /3 N 4 PVC 100** CP /4 N 5 PVC CP /6 N 6 HDPE CP /1.5 N 7 HDPE CP /2 N 8 HDPE CP /2 N 9 Silent HDPE CP /2.5 N 10 HDPE CP /3 N 11 HDPE CP /4 N 12 HDPE CP /6 N 13 PVC CP 648-E PVC CP 648-E PVC CP 648-E (2 layer) PVC CP 648-E (2 layer) PVC CP 648-E (3 layer) Note ** = Sandwich type consruction The results from this test can be summarised as below. (NF=No failure) Specimen Integrity Insulation (minutes) (minutes) (NF) 114 -/120/ (NF) 120 (NF) -/120/ (NF) 115 -/120/ (NF) 108 -/120/ (NF) 120 (NF) -/120/ (NF) 120 (NF) -/120/ (NF) 120 (NF) -/120/ (NF) 120 (NF) -/120/ (NF) 120 (NF) -/120/ (NF) 106 -/120/

5 Page 5 of 13 pages Specimen Integrity Insulation (minutes) (minutes) (NF) 97 -/120/ (NF) 116 -/120/ (NF) 120 (NF) -/120/ (NF) 120 (NF) -/120/ /90/ (NF) 120 (NF) -/120/ /0/ /0/0 CSIRO Fire-resistance test report numbered FSV 1028 Additionally, on 10 January 2004, this Division conducted a full-scale fire-resistance test in accordance with AS and AS on a 150-mm thick concrete slab system incorporating twenty six pipe penetrations. The systems are summarised in the table below. All of the pipes penetrated into the furnace by 100 mm and extended out by at least 2000 mm on the unexposed face of the slab. The pipes were supported at points 500 mm and 1500 mm from the unexposed face of the slab. Wall Slab Width / Protection Specimen Designation PVC CP /1.5 N 1 PVC CP /2 N 2 PVC CP /2.5 N 3 PVC CP /3 N 4 PVC 100** CP /4 N 5 PVC CP /6 N 6 HDPE CP /1.5 N 7 HDPE CP /2 N 8 HDPE CP /2 N 9 Silent HDPE CP /2.5 N 10 HDPE CP /3 N 11 HDPE CP /4 N 12 HDPE CP /6 N 13 PE CP /4 N 14 HDPE CP /6 N 15 PP CP /2.5 N 16 Silere PP CP /4 N 17 Silere PVC CP 648-E 18 PVC CP 648-E 19 PVC CP 648-E 20 (2 layers) PVC 100** CP 648-E (2 layers) 21

6 Page 6 of 13 pages Wall Slab Width / Protection Specimen Designation PVC CP 648-E 22 (3 layers) CP 611 A 23 PVC Electrical Conduit +cables PVC Electrical Conduit +cables Electrical Cables Electrical cables CP 611 A 24 3 x 2.5mm² Bundle x 2.5mm² CP 611 A CP 611 A 26 Note: ** = Sandwich type construction The results from this test can be summarised as below. (NF = No failure) Specimen Integrity Insulation (minutes) (minutes) (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ /180/ /120/ (NF) 240 (NF) -/240/ (NF) 6 -/240/ (NF) 240 (NF) -/240/ /0/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ (NF) 240 (NF) -/240/ /120/ /90/ (NF) 240 (NF) -/240/ (NF) 229 -/240/ (NF) 220 -/240/ (NF) 204 -/240/180 The pipes for these various tests were manufactured in compliance with the following national standards.

7 Page 7 of 13 pages PP-R DIN 8077/8078 PVC PN12 AS/NZS 1477 PP DIN 8077/8078 PE DIN 8074/8075 PP (Silere) DIN DIN 4102 HDPE PE80 Spec No. 005 UC No. W231 HDPE Silent Geberit Silent PVC AS/NZS 1260 Collating the results for the various pipe materials in order to interpolate the results we can provide the following tables, which include the additional systems requiring assessment (indicated in yellow) PVC CP 643 N Firestop Jackets Element Mounting Wall Wall (Bl) Surface CP /1.5 N -/180/180 Wall (Pl) Surface CP /1.5 N -/120/90 Wall (Bl) Flush CP /1.5 N -/240/240 Wall (Bl) Surface CP /1.5 N -/240/240 Wall (Bl) Surface CP /1.5 N -/240/240 Wall (Pl) Surface CP /1.5 N -/120/90 Floor Surface CP /1.5 N -/240/240 Wall (Bl) Surface CP /1.5 N -/180/180 Wall (Bl) Surface CP /1.5 N -/240/240 Wall (Bl) Flush CP /1.5 N -/240/240 Wall (Bl) Flush CP /1.5 N -/240/240 Floor Flush CP /1.5 N -/240/240 Floor Surface CP /1.5 N -/240/240 Wall (Pl) Surface CP /2 N -/120/120 Floor Surface CP /2 N -/240/240 Wall (Bl) Surface CP /2 N -/180/180 Wall (Bl) Flush CP /2 N -/240/240 Wall (Bl) Surface CP /2 N -/240/240 Wall (Pl) Surface CP /2.5 N -/120/90 Floor Surface CP /2.5 N -/240/240 Wall (Bl) Surface CP /2.5 N -/180/180 Wall (Bl) Flush CP /2.5 N -/240/240 Wall (Bl) Surface CP /2.5 N -/240/240 Wall (Pl) Surface CP /3 N -/120/90 Floor Surface CP /3 N -/240/240 Wall (Bl) Surface CP /3 N -/180/180 Wall (Bl) Flush CP /3 N -/240/240 Wall (Bl) Surface CP /3 N -/240/240 Wall (Pl) Surface 100** CP /4 N -/120/120 Wall (Pl) Surface CP /4 N -/120/120 Floor Flush 100** CP /4 N -/240/240 Floor Flush CP /4 N -/240/240 Wall (Bl) Flush CP /4 N -/240/240

8 Page 8 of 13 pages Element Mounting Wall Wall (Bl) Surface CP /4 N -/240/240 Wall (Bl) Surface CP /4 N -/180/180 Floor Flush CP /4 N -/240/240 Wall (Pl) Surface CP /6 N -/120/120 Floor Surface CP /6 N -/240/240 Wall (Bl) Flush CP /6 N -/240/240 Wall (Bl) Surface CP /6 N -/240/240 Wall (Bl) Surface CP /6 N -/90/90 Wall (Bl) Surface CP /6 N -/180/180 Floor Flush CP /6 N -/180/180 Note: ** = Sandwich type construction Bl=Blockwork, brickwork or concrete, Pl=Plasterboard PVC CP 648-E and CP 648-S Firestop wraps Element Wall Protection Wall (Pl) CP 648-E -/120/120 Wall (Pl) CP 648-S-50/1.5 -/120/120 Wall (Pl) CP 648-E -/120/120 Wall (Pl) CP 648-S-50/1.5 -/120/120 Wall (Pl) CP 648-E -/120/120 Wall (Pl) CP 648-S-63/2 -/120/120 Wall (Pl) CP 648-E -/90/90 Wall (Pl) CP 648-S-75/2.5 -/90/90 Wall (Pl) CP 648-E -/120/120 (2 layer) Wall (Pl) CP 648-S-90/3 -/120/120 Wall (Pl) 100** CP 648-E (2 layers) Wall (Pl) CP 648-E (2 layers) Wall (Pl) CP 648-E (3 layers) Floor CP 648-E -/0/0 -/0/0 -/0/0 -/240/240

9 Page 9 of 13 pages Element Wall Protection Floor CP 648-E Floor CP 648-E (2 layers) Floor CP 648-E (2 layers) Floor CP 648-E (3 layers) Note: ** = Sandwich type construction PL = Plasterboard -/240/240 -/240/240 -/120/120 -/90/90 HDPE CP 643 N Firestop Jackets Element Mounting Wall Wall (Pl) Surface CP /1.5 N -/120/120 Floor Surface CP /1.5 N -/240/240 Wall (Pl) Surface CP /2 N -/120/120 Floor Surface 56* CP /2 N -/240/240 Wall (Pl) Surface 56* CP /2 N -/120/120 Floor Surface CP /2 N -/240/240 Wall (Pl) Surface CP /2 N -/120/90 Wall (Pl) Surface 63* CP /2 N -/120/90 Wall (Pl) Surface CP /2.5 N -/120/90 Floor Surface CP /2.5 N -/240/240 Wall (Pl) Surface CP /3 N -/120/90 Floor Surface CP /3 N -/240/240 Wall (Pl) Surface CP /4 N -/120/90 Floor Surface CP /4 N -/180/180 Wall (Pl) Surface CP /6 N -/120/120 Floor Surface CP /6 N -/120/120 Note - * HDPE Silent pipe, Pl=Plasterboard PE CP 643 N Firestop Jackets Element Mounting Wall (Bl) Flush CP /1.5 N -/240/240 Floor Surface CP /1.5 N -/240/240 Floor Flush CP /1.5 N -/240/240 Wall (Bl) Surface 50 > CP /1.5 N -/180/180 Wall (Bl) Surface 50 > CP /1.5 N -/240/240 Wall (Bl) Surface 63 > CP //2 N -/180/180 Wall (Bl) Flush 63 > CP /2 N -/240/240 Wall (Bl) Surface 63 > CP /2 N -/240/240 Wall (Bl) Surface 75 > CP /2.5 N -/180/180

10 Page 10 of 13 pages Element Mounting Wall (Bl) Flush 75 > CP /2.5 N -/240/240 Wall (Bl) Surface 75 > CP /2.5 N -/240/240 Wall (Bl) Surface 90 > CP /3 N -/180/180 Wall (Bl) Flush 90 > CP /3 N -/240/240 Wall (Bl) Surface 90 > CP /3 N -/240/240 Wall (Bl) Surface CP /4 N -/240/240 Wall (Bl) Surface CP /4 N -/180/180 Floor Flush CP /4 N -/240/240 Floor Surface CP /4 N -/240/240 Wall (Bl) Flush CP /4 N -/240/240 Wall (Bl) Flush CP /6 N -/240/240 Wall (Bl) Surface CP /6 N -/180/180 Wall (Bl) Surface CP /6 N -/240/240 Floor Surface CP /6 N -/240/240 Floor Flush CP /6 N -/60/60 Bl=Blockwork ABS CP 643 N Firestop jackets Element Mounting Wall Wall (Bl) Surface CP /4 N -/240/240 Wall (Bl) Surface CP /6 N -/120/120 Wall (Bl) Surface CP /4 N -/180/120 Floor Surface CP /4 N -/180/180 Floor Surface CP /6 N -/240/240 Floor Surface CP /6 N -/240/240 The critical factors that affect the fire performance of plastic pipe penetrations as noted in AS/NZS are the pipe material, the pipe diameter and the pipe wall thickness. Other critical factors are the diameter of the collar, the type of intumescent and the ratio of the intumescent material to the enclosed area of the collar. The use of the same collar and the same pipe material eliminates most of the performance effecting variations and therefore only the pipe diameter and wall thickness need to be considered. The table above lists the penetration systems tested along with the additional systems requiring assessment. Addressing the performance requirements of the system it is considered that if the same collar is used to protect penetrations incorporating plastic pipes of the same material of maximum dimensions and minimum dimensions and both achieve the same fire-resistance levels then the same fire-resistance levels can be assigned to plastic pipes of the same material whose dimension fall between those of the tested systems. Additionally the consistency of performance can be taken into account in that if the protection achieves the same result over a relatively extensive rang of pipes of the same material then interpolation between the tests may be possible. These criteria are satisfied by all of the proposed systems listed above.

11 Page 11 of 13 pages Additionally, as part of the test programme, you installed five wall and five floor penetrations incorporating variously sized PVC pipes protected by your CP 648 Firestop wraps. The testing was conducted using your CP 648-E system in which a continuous wrap is wound spirally around the pipe to provide the specified number of layers. An alternative is to use a series of single discrete strips cut to length equivalent to the diameter of the pipe or the previous wrap layer. This system is designated CP 648-S Firestop wraps and would provide equivalent or marginally more intumescent material and therefore would not detrimentally affect the established fire performance if the CP 648-E was replaced with the CP 648-S system. CONCLUSION Based on the test information and the performance factors detailed above it is the opinion of the Division that the penetration systems listed below would be capable of achieving the stated fire-resistance levels if tested in accordance with AS and AS when installed into concrete, blockwork, masonry or Hebel wall systems of nominated minimum thickness provided that the pipe is not of sandwich construction and is manufactured in accordance with the standards listed above or equivalent. Mounting Wall Min. Wall PVC Surface CP /1.5 N -/180/180 PVC Surface CP /1.5 N -/180/180 PVC Surface CP /2 N -/180/180 PVC Surface CP /2.5 N -/180/180 PVC Surface CP /3 N -/180/180 PVC Surface 100** CP /4 N -/180/180 PVC Surface CP /4 N -/180/180 PVC Surface CP /6 N -/180/180 PVC Surface CP /1.5 N -/240/240 PVC Surface CP /1.5 N -/240/240 PVC Surface CP /2 N -/240/240 PVC Surface CP /2.5 N -/240/240 PVC Surface CP /3 N -/240/240 PVC Surface 100** CP /4 N -/240/240 PVC Surface CP /4 N -/240/240 PVC Surface CP /6 N -/240/240 PVC Flush CP /1.5 N -/240/240 PVC Flush CP /1.5 N -/240/240 PVC Flush CP /2 N -/240/240 PVC Flush CP /2.5 N -/240/240 PVC Flush CP /3 N -/240/240 PVC Flush CP /4 N -/240/240 PVC Flush CP /6 N -/240/240 PE Surface CP /1.5 N -/180/180 PE Surface CP /2 N -/180/180 PE Surface CP /2.5 N -/180/180

12 Page 12 of 13 pages Mounting Wall Min. Wall PE Surface CP /3 N -/180/180 PE Surface CP /4 N -/180/180 PE Surface CP /6 N -/180/180 PE Surface CP /1.5 N -/240/240 PE Surface CP /2 N -/240/240 PE Surface CP /2.5 N -/240/240 PE Surface CP /3 N -/240/240 PE Surface CP /4 N -/240/240 PE Surface CP /6 N -/240/240 PE Flush CP /1.5 N -/240/240 PE Flush CP /2 N -/240/240 PE Flush CP /2.5 N -/240/240 PE Flush CP /3 N -/240/240 PE Flush CP /4 N -/240/240 PE Flush CP /6 N -/240/240 ABS Surface CP /4 N -/180/120 ABS Surface CP /4 N -/240/240 ABS Surface CP /6 N -/120/120 Note: ** = Sandwich type construction Additionally, it is also the opinion of the Division that the penetration systems listed below would be capable of achieving the stated fire-resistance levels if tested in accordance with AS and AS when installed into an approved 120/120/120 or -/120/120 framed wall systems (or concrete, blockwork, masonry or Hebel wall systems) of nominated minimum thickness, provided that the pipe is not of sandwich construction and is manufactured in accordance with the standards listed above or equivalent. Mounting Wall Min. Wall / Protection System PVC Surface CP /1.5 N -/120/90 PVC Surface CP /1.5 N -/120/90 PVC Surface CP /2 N -/120/120 PVC Surface CP /2.5 N -/120/90 PVC Surface CP /3 N -/120/90 PVC Surface 100** CP /4 N -/120/120 PVC Surface CP /4 N -/120/120 PVC Surface CP /6 N -/120/120 HDPE Surface CP /1.5 N -/120/120 HDPE Surface CP /2 N -/120/120 HDPE Surface CP /2 N -/120/90 HDPE Surface CP /2.5 N -/120/90 HDPE Surface CP /3 N -/120/90

13 Page 13 of 13 pages Mounting Wall Min. Wall / Protection System HDPE Surface CP /4 N -/120/90 HDPE Surface CP /6 N -/120/120 HDPE Silent HDPE Silent Surface CP /2 N -/120/120 Surface CP /2 N -/120/90 PVC Flush CP 648-E -/120/120 PVC Flush CP 648-E -/120/120 PVC Flush CP 648-E -/120/90 PVC Flush CP 648-E -/90/90 PVC Flush CP 648-E (2 layer) -/120/120 PVC Flush CP 648-S-50/1.5 -/120/120 PVC Flush CP 648-S-50/1.5 -/120/120 PVC Flush CP 648-S-63/2 -/120/90 PVC Flush CP 648-S-75/2.5 -/90/90 PVC Flush CP 648-S-90/3 -/120/120 Note: ** = Sandwich type construction TERM OF VALIDITY This assessment report will lapse on 31 July Should you wish us to re-examine this assessment with a view to the possible extension of its term of validity, would you please apply to us three to four months before the date of expiry. This Division reserves the right at any time to amend or withdraw this report in the light of new knowledge. Yours faithfully, Garry E Collins Manager, Fire Testing and Assessments. 14 July 2010

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The fire resistance performance

More information

FIRE TEST REPORT FH 5154

FIRE TEST REPORT FH 5154 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5154 CONE CALORIMETER TEST AND NCC SPECIFICATION C1.10

More information

Demonstrate knowledge of electrical theory for Electrical Service Technician B

Demonstrate knowledge of electrical theory for Electrical Service Technician B Demonstrate knowledge of electrical theory for Electrical Service Technician B 10937 version 4 Page 1 of 5 Level 3 Credits 3 Purpose 'Electrical Service Technician B' (EST B) refers to a class of electrical

More information

Technical Data Sheet. Hilti Firestop Collar CFS-C P. European Technical Approval ETA N o 10/0404. Issue 08 / Hilti Firestop Collar CFS-C P

Technical Data Sheet. Hilti Firestop Collar CFS-C P. European Technical Approval ETA N o 10/0404. Issue 08 / Hilti Firestop Collar CFS-C P Technical Data Sheet Hilti Firestop Collar CFS-C P Hilti Firestop Collar CFS-C P European Technical Approval ETA N o 10/0404 Issue 08 / 2015 Hilti Firestop Collar CFS-C P Issue 02/2015 page 1 General information

More information

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for: Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: Fire resistance test in accordance

More information

Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for:

Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for: assessment report Title: The Fire Resistance Performance of Modified Doorsets WF Assessment Report No: 187254 Prepared for: Phoenix Door Panels Ltd. Westnewlands Ind. Estate Somersham Huntingdon Cambs

More information

With Compliments PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : : 1006

With Compliments PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : : 1006 For the Attention of: Mr Ian Davies Mideas Limited 12 Openshaw Drive Blackburn Lancashire BB1 8RH With Compliments DATE REPORT ISSUED: 10/11/2006 PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : 99316

More information

FIRE ASSESSMENT REPORT FAR 4659

FIRE ASSESSMENT REPORT FAR 4659 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE ASSESSMENT REPORT FAR 4659 ASSESSMENT REPORT ON FIRE PERFORMANCE OF KNAUF

More information

CERTIFICATE OF CONFORMITY

CERTIFICATE OF CONFORMITY CERTIFICATE OF CONFORMITY This is to certify that Product Description, Purpose or Use Polyethylene (PE) pipes for pressure applications Certificate Holder ASA Plastics Pty Ltd Polyethylene (PE) Pipes Complies

More information

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date: Title: Fire Resistance Test In Accordance With BS EN 1364-1: 1999 On A Glazed Screen Assembly WF Report No: 164311, Prepared for: AGC Flat Glass Europe. Chaussee de la Hulpe 166 1170 Brussels. Date: 19

More information

STEEL XLERPLATE SIZE SCHEDULES EFFECTIVE JANUARY 2015

STEEL XLERPLATE SIZE SCHEDULES EFFECTIVE JANUARY 2015 XLERPLATE SIZE SCHEDULES EFFECTIVE JANUARY 2015 STEEL General Information WHAT IS A SIZE SCHEDULE? A size schedule is a table showing the XLERPLATE steel sizes available from BlueScope in a given grade

More information

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers Warringtonfire Holmesfield Road Warrington WA1 2DS T: +44 (0)1925 655 116 F: +44 (0)1925 655 419 info.warrington@warringtonfire.com warringtonfire.com Title: The Fire Resistance Performance Of Doorsets

More information

CERTIFICATE OF APPROVAL No CF 249. Yung Chi Paint & Varnish Mfg. Co., Ltd

CERTIFICATE OF APPROVAL No CF 249. Yung Chi Paint & Varnish Mfg. Co., Ltd CERTIFICATE OF APPROVAL No CF 249 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Yung Chi Paint & Varnish

More information

REPORT No EN-S AJ

REPORT No EN-S AJ Pollution Control Consultancy and Design ALEX JOCHELSON ABN 71 776 800 318 MEMech MIEAust CPEng ( Reg ) Air, Noise and Water Pollution Assessment and Engineering Control Telephone: (02) 9238 2053 Facsimile:

More information

ENGINEERING REPORT RE15012

ENGINEERING REPORT RE15012 Analysis of Proposed Load Restraint Configurations for Round Subject Cotton Modules Client Cotton Australia Pty Ltd Client Address 115 Campbell St, Toowoomba, QLD 4350 Revision 0 Date 10/02/2015 Report

More information

RUBBER BELLOWS TYPE 1A & 1S SERIES

RUBBER BELLOWS TYPE 1A & 1S SERIES RUBBER BELLOWS TYPE 1A & 1S SERIES Description: Vibracoustics Ltd Reiflexa Bellows are made from various elastomers reinforced with high tensile textile or steel cords to provide the flexible elements

More information

ENGINEERING REPORT RE11049

ENGINEERING REPORT RE11049 Subject Client Client Address Analysis of Proposed Load Restraint Configurations for Round Cotton Modules B-Safe Winches Australia (a Division of Dangerous Goods Equipment Pty Ltd) PO Box 4029 Eight Mile

More information

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No: Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The fire resistance performance

More information

PROPOSED HELICOPTER LANDING PAD 85 MILL ROAD LARA

PROPOSED HELICOPTER LANDING PAD 85 MILL ROAD LARA PROPOSED HELICOPTER LANDING PAD 85 MILL ROAD LARA Assessment of Helicopter Noise A report Prepared on behalf of: JamCo Constructions Pty Ltd PO Box 631 Yarraville Victoria 3013 Ref: 11573-3jg March 2015

More information

NZQA registered unit standard version 1 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 5 Page 1 of 5 Title Demonstrate and apply knowledge of theory and practice for registration of electrical workers (stage 3) Level 4 Credits 3 Purpose This unit standard is for people who are completing an

More information

AS/NZS :2011. Gate valves for waterworks purposes AS/NZS :2011. Part 1: Metal seated. Australian/New Zealand Standard

AS/NZS :2011. Gate valves for waterworks purposes AS/NZS :2011. Part 1: Metal seated. Australian/New Zealand Standard AS/NZS 2638.1:2011 Incorporating Amendment No. 1 Australian/New Zealand Standard Gate valves for waterworks purposes Part 1: Metal seated AS/NZS 2638.1:2011 AS/NZS 2638.1:2011 This joint Australian/New

More information

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength Report No: 181947 Test of: Reversible aluminium/timber window Tested to: BS 6375-2:2009 Performance of windows & doors Part 2: Operation & strength For: A/S Peder Nielsen Beslagfabrik Norregade 25 Bronderslev

More information

CERTIFICATE OF APPROVAL No CF 5267 SHERWIN-WILLIAMS

CERTIFICATE OF APPROVAL No CF 5267 SHERWIN-WILLIAMS CERTIFICATE OF APPROVAL No CF 5267 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Tower Works, Kestor

More information

Multideck 50-V2 Features and Applications

Multideck 50-V2 Features and Applications Features and Applications is a dovetail profile deck with a depth of 50mm providing spans up to 4m unpropped. Greater Design Efficiency The larger range of Multideck gauge thicknesses available allow much

More information

BALL BEARING TESTS TO EVALUATE DUROID REPLACEMENTS

BALL BEARING TESTS TO EVALUATE DUROID REPLACEMENTS BALL BEARING TESTS TO EVALUATE DUROID REPLACEMENTS M J Anderson, ESTL, AEA Technology Space, RD1/164 Birchwood Technology Park, Warrington, UK WA3 6AT Tel: +44 1925 253087 Fax: +44 1925 252415 e-mail:

More information

Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Delsa Marmi Pty Ltd

Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Delsa Marmi Pty Ltd Level 1 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Delsa Marmi Pty Ltd Trading as Delsa Marmi Pty Ltd the right to use the WaterMark as shown above

More information

Green Star - Office Interiors v1.1 Inn-3 Environmental Design Initiatives

Green Star - Office Interiors v1.1 Inn-3 Environmental Design Initiatives Green Star - Office Interiors v1.1 Inn-3 Environmental Design Initiatives Points available: 5 Points claimed: 1 CIR or TC Used: N Round 1 Assessment Comments The project may wish to consider providing

More information

Colston Budd Rogers & Kafes Pty Ltd as Trustee for C & B Unit Trust ABN

Colston Budd Rogers & Kafes Pty Ltd as Trustee for C & B Unit Trust ABN as Trustee for C & B Unit Trust ABN 27 623 918 759 Our Ref: 20 July, 2017 TR/10419/jj Transport Planning Traffic Studies Parking Studies Frasers Property Australia PO Box 4148 SHELLHARBOUR NSW 2529 Attention:

More information

CERTIFICATE OF APPROVAL No CF 5069 HILTI AG

CERTIFICATE OF APPROVAL No CF 5069 HILTI AG CERTIFICATE OF APPROVAL No CF 5069 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of BU Chemicals, Feldkircherstraße

More information

SAMPLE RETENTION POLICY

SAMPLE RETENTION POLICY For the Attention of: Sandy Chadha Supreme Imports Limited 4 Beacon Road Ashburton Park Asburton Road West, Trafford Park Manchester M17 1AF With Compliments DATE REPORT ISSUED 17/01/2011 PLEASE FIND ENCLOSED

More information

Title: WF Report No:

Title: WF Report No: Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance

More information

FIRE TEST REPORT FH 5078

FIRE TEST REPORT FH 5078 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5078 CONE CALORIMETER TEST AND NZBC ACCEPTABLE SOLUTIONS

More information

National Certificate in Electricity Supply (Distribution Faultman) (Level 4) with strands in Line Mechanic, and Electrician

National Certificate in Electricity Supply (Distribution Faultman) (Level 4) with strands in Line Mechanic, and Electrician NZQF NQ Ref 1624 Version 4 Page 1 of 9 National Certificate in Electricity Supply (Distribution Faultman) (Level 4) with strands in Line Mechanic, and Electrician Level 4 Credits 76-78 This qualification

More information

Mattest (Ireland) Ltd

Mattest (Ireland) Ltd Unit 18 University Hall, Sarsfield Road, Wilton, Cork Registration number: 289T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration

More information

For personal use only

For personal use only AER ISSUES NETWORK REVENUES DRAFT DECISIONS FOR ACT AND NSW ENERGY CUSTOMERS The Australian Energy Regulator (AER) has issued draft decisions on the revenue proposals submitted by ACT and NSW distribution

More information

Amendment 69 FR (20 December 2004) Section 5 Hydraulic brake hose, brake hose assemblies, and brake hose end fittings ESN270529

Amendment 69 FR (20 December 2004) Section 5 Hydraulic brake hose, brake hose assemblies, and brake hose end fittings ESN270529 Vehicle Certification Agency 1 The Eastgate Office Centre Eastgate Road Bristol BS5 6XX United Kingdom Telephone: +44 (0) 117 951 5151 Fax: +44 (0) 117 952 4103 Email: enquiries@vca.gov.uk www.dft.gov.uk/vca/

More information

Multideck 80-V2 Features and Applications

Multideck 80-V2 Features and Applications Features and Applications is designed to incorporate all the advantages of the Multideck 60-V2 but in a deeper profile to provide longer spans up to 5.4m unpropped. Concrete Volume Savings Due to its unique

More information

FIRE TEST REPORT FH 5728

FIRE TEST REPORT FH 5728 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5728 CONE CALORIMETER TEST AND NZBC VERIFICATION METHOD

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION TS96 AR ISSUE 5 Issued 2014-05 Amendment Record NOTE: The issue status of this document remains unchanged as there have been no changes to the technical content. SAE INDUSTRY TECHNOLOGIES

More information

WSAA PRODUCT APPRAISAL CERTIFICATE

WSAA PRODUCT APPRAISAL CERTIFICATE WSAA PRODUCT APPRAISAL CERTIFICATE Pty Ltd AWASHAFT DN 400 / DN 600 / DN 800 Polypropylene (PP) Maintenance Shafts and Chambers AWASHAFT DN 400 / DN 600 / DN 800 Polypropylene (PP) Maintenance Shafts and

More information

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference: Exova Warringtonapt Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com BS EN 14351-1:2006 Test

More information

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN 1634-1: 2000 Report No: 163712 A Prepared for: Novoferm GmbH Haldern Isselburger Str.

More information

National Certificate in Motor Industry (Automotive Servicing)

National Certificate in Motor Industry (Automotive Servicing) NZQF NQ Ref 0138 Version 4 Page 1 of 8 National Certificate in Motor Industry (Automotive Servicing) Level 2 Credits 67-68 This qualification has been reviewed. The last date to meet the requirements is

More information

AIR DISPERSION MODELLING FOR INTEL IRELAND LTD OF AMMONIA EMISSIONS

AIR DISPERSION MODELLING FOR INTEL IRELAND LTD OF AMMONIA EMISSIONS AIR DISPERSION MODELLING FOR INTEL IRELAND LTD OF AMMONIA EMISSIONS Technical Report Prepared For Intel Ireland Ltd. Collinstown Industrial Estate Leixlip County Kildare Technical Report Prepared By Edward

More information

Report Number BTC 12261F

Report Number BTC 12261F Report Number BTC 6F A FIRE RESISTANCE TEST ON A 5m HIGH X m WIDE GYPROC SHAFTWALL SYSTEM INCORPORATING A 6mm METAL STUD FRAMEWORK CLAD WITH A DOUBLE LAYER OF 5mm GYPROC FIRELINE, EXPOSED TO THE FIRE FROM

More information

The Waste Electrical and Electronic Equipment Regulations 2013 (as amended) Notification of grant of approval of an authorised treatment facility

The Waste Electrical and Electronic Equipment Regulations 2013 (as amended) Notification of grant of approval of an authorised treatment facility Mr Simon Gilchrist BCMY LTD Unit 1 Fort Road Wick Littlehampton West Sussex Bn17 7QU Our ref: WEE/FX0002ZS/ATF Date: 09 November 2017 Dear Mr Simon Gilchrist, The Waste Electrical and Electronic Equipment

More information

piece of straight pipe with a minimum length of 25 cm. (see figure 13) For this purpose the 45 long bend is included in the Wavin AS program.

piece of straight pipe with a minimum length of 25 cm. (see figure 13) For this purpose the 45 long bend is included in the Wavin AS program. Recommendations 3.9 Sound insulation recommendations National / Local building regulations should be observed where applicable. In order to achieve optimal sound insulation it is highly recommended to

More information

SECONDARY FUEL TESTING ARRANGEMENTS

SECONDARY FUEL TESTING ARRANGEMENTS SECONDARY FUEL TESTING ARRANGEMENTS SUMMARY DOCUMENT JULY 2010 Note: 1. This summary document has been produced by EirGrid for information only. Parties should base any decision or actions on the legally

More information

EMGA Mitchell McLennan Pty Limited (EMM) has been engaged to complete quarterly attended noise

EMGA Mitchell McLennan Pty Limited (EMM) has been engaged to complete quarterly attended noise 12 December 2014 Level 5, 21 Bolton Street Newcastle NSW 2300 PO Box 506 Leonard Sharp Environment and Community Liaison Officer Broken Hill Operations Pty Ltd CBH Resources Rasp Mine Newcastle, NSW, 2300

More information

IMO. All IMO Members and Contracting Governments to the International Convention for the Safety of Life at Sea (SOLAS), 1974

IMO. All IMO Members and Contracting Governments to the International Convention for the Safety of Life at Sea (SOLAS), 1974 INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 Telex: 23588 IMOLDN G IMO E Ref. T2-NAVSEC/2.11.1 8 December 2003 To: Subject: All IMO

More information

Testing of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist.

Testing of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist. DC1333 Testing of aier Plasterboard to AS/NZS 2588 (Electronic copy (PDF format) original signed by author) Author: Neil Lee Materials Scientist Reviewer: ryan Keen Senior Technician Contact: RANZ Limited

More information

ESS Lighting Instruction Pack Original Energy Saver

ESS Lighting Instruction Pack Original Energy Saver ESS Lighting Instruction Pack Original Energy Saver For projects completed: AFTER 1 July 2014 This Instruction Pack is designed to simplify the processing of Energy Savings Certificates for commercial

More information

WELLINGTON, NEW ZEALAND. PURSUANT to sections 152, 155(a) and (e) and 158(a)(i) of the Land Transport Act 1998

WELLINGTON, NEW ZEALAND. PURSUANT to sections 152, 155(a) and (e) and 158(a)(i) of the Land Transport Act 1998 WELLINGTON, NEW ZEALAND PURSUANT to sections 152, 155(a) and (e) and 158(a)(i) of the Land Transport Act 1998 I, Gerry Brownlee, Minister of Transport, HEREBY make the following ordinary Rule: Land Transport

More information

Multideck 60-V2. Contents

Multideck 60-V2. Contents The original and still the most popular deck in the market is a 60mm high, structurally efficient trapezoidal profile providing an excellent composite union between steel and concrete to maximise the load

More information

Certifikat och provningsprotokoll för art. 4512, 4513, 4514 och 4515

Certifikat och provningsprotokoll för art. 4512, 4513, 4514 och 4515 Certifikat och provningsprotokoll för art. 4512, 4513, 4514 och 4515 Innehållsförteckning: Declaration of conformity... sid 2 SINTEF Produktdokumentation... sid 3 Efectis Nederland BV Brandtestunderlag...

More information

CERTIFICATE OF APPROVAL No CF 5172 ETEX BUILDING PERFORMANCE LTD

CERTIFICATE OF APPROVAL No CF 5172 ETEX BUILDING PERFORMANCE LTD CERTIFICATE OF APPROVAL No CF 5172 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Gordano House, Marsh

More information

Mobilehome Park Utility Upgrade Program

Mobilehome Park Utility Upgrade Program Mobilehome Park Utility Upgrade Program A new opportunity for mobilehome communities PLEASE NOTE: Information reflects current advice letter filed with but not yet approved by the CPUC Commission Approves

More information

Static Insertion Loss of Flexible Ducting: Estimation of Performance of Non-Tested Sizes by Interpolation

Static Insertion Loss of Flexible Ducting: Estimation of Performance of Non-Tested Sizes by Interpolation Westaflex Australia Pty. Ltd. Static Insertion Loss of Flexible Ducting: Estimation of Performance of Non-Tested Sizes by Interpolation NOISE Report No. 302343/2 (Issue 2) Prepared by Vipac Engineers &

More information

Part 2 GAZETTE OFFICIELLE DU QUÉBEC, March 9, 2016, Vol. 148, No

Part 2 GAZETTE OFFICIELLE DU QUÉBEC, March 9, 2016, Vol. 148, No Part 2 GAZETTE OFFICIELLE DU QUÉBEC, March 9, 2016, Vol. 148, No. 10 1287 M.O., 2016 Order number 2016-01 of the Minister of Transport, Sustainable Mobility and Transport Electrification dated 26 February

More information

Introduction. Our Ref: Chilt/IF12041 AR1. 24 th June Astra Door Controls Ltd Unit 10 Astra Business Centre Roman Way Preston PR2 5AP

Introduction. Our Ref: Chilt/IF12041 AR1. 24 th June Astra Door Controls Ltd Unit 10 Astra Business Centre Roman Way Preston PR2 5AP Chiltern House Stocking Lane Hughenden Valley High Wycombe Buckinghamshire HP14 4ND UK t +44 (0) 1494 569 800 f +44 (0) 1494 564895 e cif@chilternfire.co.uk w www.chilternfire.co.uk Our 24 th June 2012

More information

Over 330 Clarifier installations in 3 continents

Over 330 Clarifier installations in 3 continents LAMELLA SEPARATORS Over 330 Clarifier installations in 3 continents With over 60 years of design and commissioning expertise, you can be assured that your Hydroflux Epco clarifier will perform consistently

More information

AMIAD "TAF" FILTER SERIES

AMIAD TAF FILTER SERIES AMIAD "TAF" FILTER SERIES 2" - 3" Automatic electric filters for flow rates up to 50 m 3 /h; 220 USgpm An innovative self-cleaning filter, constructed of high quality plastic; suitable for a large variety

More information

NZQA registered unit standard version 1 Page 1 of 6

NZQA registered unit standard version 1 Page 1 of 6 Page 1 of 6 Title Demonstrate knowledge of theory and legislation for registration of electrical appliance servicepersons Level 3 Credits 3 Purpose This unit standard covers the theory assessment required

More information

CERTIFICATE OF APPROVAL No CF 5235 AVIANS INNOVATIONS TECHNOLOGY PVT. LTD

CERTIFICATE OF APPROVAL No CF 5235 AVIANS INNOVATIONS TECHNOLOGY PVT. LTD CERTIFICATE OF APPROVAL No CF 5235 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of AVIANS INNOVATIONS

More information

Net Metering Service. Customer Information Package

Net Metering Service. Customer Information Package Net Metering Service Customer Information Package March 20, 2017 Net Metering - The means of measuring the difference between the electricity supplied by an electric utility and the electricity generated

More information

Mattest (Ireland) Ltd

Mattest (Ireland) Ltd Unit 2, Northwest Business Park, Ballycoolin, Dublin 15 Testing Laboratory Registration number: 286T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing

More information

Godkjennelsesdokumenter for art. 4509, 4511

Godkjennelsesdokumenter for art. 4509, 4511 Godkjennelsesdokumenter for art. 4509, 4511 Innholdsliste: Samsvarserklæring side 2 SINTEF Produktdokumentasjon 050-0204 side 3 Efectis Nederland BV branntestunderlag side 8 Efectis Nederland BV testrapport

More information

CARPARK, RAMP AND DRIVEWAY CERTIFICATION OF RESIDENTIAL USE DEVELOPMENT. Prepared for: Harvey Property Investments Pty Ltd

CARPARK, RAMP AND DRIVEWAY CERTIFICATION OF RESIDENTIAL USE DEVELOPMENT. Prepared for: Harvey Property Investments Pty Ltd CARPARK, RAMP AND DRIVEWAY CERTIFICATION OF RESIDENTIAL USE DEVELOPMENT 8-9 Harvey Place in Toongabbie Prepared for: Harvey Property Investments Pty Ltd N1615708A (Version 1b) May 2016 Suite 195, 79 to

More information

CARES Technical Approval Report TA1C

CARES Technical Approval Report TA1C CARES Technical Approval Report TA1C - 5057 Issue 1 LENTON Standard, Position, Parallel Bolt Couplers and Mechanical Anchor Assessment of the LENTON Standard, Standard Transition, Position, Parallel Bolt

More information

ArcelorMittal Europe - Long products Sections and Merchant Bars HISTAR. Innovative high strength steels for economical steel structures

ArcelorMittal Europe - Long products Sections and Merchant Bars HISTAR. Innovative high strength steels for economical steel structures ArcelorMittal Europe - Long products Sections and Merchant Bars HISTAR Innovative high strength steels for economical steel structures Shanghai World Finance Center, P.R. China Innovative high strength

More information

Ms. Tracey Pennell Senior Counsel Newfoundland and Labrador Hydro P.O. Box St. John's, NL A1B 4K7

Ms. Tracey Pennell Senior Counsel Newfoundland and Labrador Hydro P.O. Box St. John's, NL A1B 4K7 NEWFOUNDLAND AND LABRADOR BOARD OF COMMISSIONERS OF PUBLIC UTILITIES 120 Torbay Road, P.O. Box 21040, St. John's, Newfoundland and Labrador, Canada, AIA 5B2 E-mail: TraceyPennell@nlh.nl.ca 2017-01-27 Ms.

More information

cable management Pit / Vault System Series

cable management Pit / Vault System Series cable management Pit / Vault System Series brought to you by channell Dedicated to protecting fiber optics through design, innovation, and service. The Only One of its Kind in the World. Ductile Iron Lid

More information

GRP backing flanges DIN 2501 Flange connecting dimension PN10 WORK STANDARD. GRP backing flanges made of Polyester resin.

GRP backing flanges DIN 2501 Flange connecting dimension PN10 WORK STANDARD. GRP backing flanges made of Polyester resin. GRP backing flanges DIN 2501 Flange connecting dimension PN10 1310-WN-en 06 10.2002 GRP backing flanges made of Polyester resin. D 45 e d2 d1 b1 k Flange connecting dimensions according to DIN 2501 Part

More information

650mA Phase Dimmable LED Driver

650mA Phase Dimmable LED Driver Installation Guide DGLC650C18PD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

weinor can hold you the safe, fast way to fix it properly

weinor can hold you the safe, fast way to fix it properly Brackets weinor can hold you the safe, fast way to fix it properly Fixing brackets Folding arm brackets We reserve the right to make technical alterations. December 06 www.weinor.co.uk Brackets 1 www.samsonawnings.co.uk

More information

Infrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0)

Infrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0) Infrastructure & Power FP M c Cann Tel: +44(0)1455 290 780 Fax: +44(0)1455 292 189 Infrastructure & Power Infrastructure & Power Power Infrastructure Cable Trough Systems FP McCann offers a specialist

More information

Carl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C

Carl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C Tallaght Business Park, Whitestown, Dublin 24 Calibration Laboratory Registration number: 270C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule bearing

More information

Fire resistance test in accordance with BS 476 Perko (R1, R2 & R21) and Perkomatic (R85) concealed door closers

Fire resistance test in accordance with BS 476 Perko (R1, R2 & R21) and Perkomatic (R85) concealed door closers Fire resistance test in accordance with BS 476 Perko (R1, R2 & R21) and Perkomatic (R85) concealed door closers Independent fire assessments for all products are effective for a five year period. Where

More information

Position Paper. Telehandler Use: Lifting Suspended Loads

Position Paper. Telehandler Use: Lifting Suspended Loads Position Paper Telehandler Use: Lifting Suspended Loads The following paper reflects the considered opinion on the Crane Association of New Zealand (Inc.) This document has been prepared by the Technical

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-32159-8 Any reference to SABS 1551-1 is deemed to be a reference to this standard (Government Notice No. 1373 of 8 November 2002) SOUTH AFRICAN NATIONAL STANDARD Check valves (flanged and

More information

Clyde Waste Transfer Facility Quarterly Truck Noise Measurements April 2009

Clyde Waste Transfer Facility Quarterly Truck Noise Measurements April 2009 REPORT 10-6815-R3 Quarterly Truck Noise Measurements April 2009 PREPARED FOR Cnr Unwin & Shirley Street ROSEHILL NSW 2142 30 APRIL 2009 HEGGIES PTY LTD ABN 29 001 584 612 Quarterly Truck Noise Measurements

More information

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document Decision 2013-127 Alberta Electric System Operator Saleski Transmission Project Needs Identification Document ATCO Electric Ltd. Saleski 901S Substation and 144-kV Transmission Line 7L142 Facility Application

More information

ASPHALT ROUND 1 PROFICIENCY TESTING PROGRAM. April 2009 REPORT NO. 605 ACKNOWLEDGEMENTS

ASPHALT ROUND 1 PROFICIENCY TESTING PROGRAM. April 2009 REPORT NO. 605 ACKNOWLEDGEMENTS ASPHALT ROUND 1 PROFICIENCY TESTING PROGRAM April 2009 REPORT NO. 605 ACKNOWLEDGEMENTS PTA wishes to acknowledge gratefully the technical assistance provided for this program by Mr Hugo Van Loon at The

More information

Metallic Gaskets for Pipe Flanges

Metallic Gaskets for Pipe Flanges ASME B16.20-2012 (Revision of ASME B16.20-2007) Metallic Gaskets for Pipe Flanges Ring-Joint, Spiral-Wound, and Jacketed AN AMERICAN NATIONAL STANDARD ASME B16.20-2012 (Revision of ASME B16.20-2007) Metallic

More information

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20 TEXAS DEPARTMENT OF INSURANCE Engineering Services Program / M03-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective

More information

ype UP T Busplugs Low Voltage Switchboard Equipment

ype UP T Busplugs Low Voltage Switchboard Equipment Busplugs Type UP Low Voltage Switchboard Equipment Publication UP 2013 Since product improvement is a continuing policy, we reserve the right to change specifications without notice. Contents Descriptive

More information

1000mA - 650mA Phase Dimmable LED Driver

1000mA - 650mA Phase Dimmable LED Driver Installation Guide DGLC1000C25PD 1000mA - 650mA Phase Dimmable LED Driver PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU

More information

Rubber Tyred Vehicles Technical Bulletin

Rubber Tyred Vehicles Technical Bulletin Rubber Tyred Vehicles Technical Bulletin Bulletin Number: TB0906 Date: 17/06/2009 Subject: TBS Design Registration 130 Purpose To inform the industry of the registration of the Transport Braking System

More information

Cut to Size Plastics Pty Ltd

Cut to Size Plastics Pty Ltd Cut Hercules to Size Engineering Plastics Australia Pty Ltd incorporating Incorporated by Hercules Cut to Engineering Size Plastics Pty Australia Ltd 2016 - VERSION C Cut ABN To 73 Size 001 909 Plastics

More information

MOT Special Notice 07-17: replacement documents, new diesel smoke limits for some vehicles, annual training and assessment reminder

MOT Special Notice 07-17: replacement documents, new diesel smoke limits for some vehicles, annual training and assessment reminder MOT Special Notice 07-17: replacement documents, new diesel smoke limits for some vehicles, annual training and assessment reminder Replacement MOT documents 1. Overview A replacement document is issued

More information

BMW of North America, LLC, Grant of Petition for Decision of. AGENCY: National Highway Traffic Safety Administration (NHTSA),

BMW of North America, LLC, Grant of Petition for Decision of. AGENCY: National Highway Traffic Safety Administration (NHTSA), This document is scheduled to be published in the Federal Register on 11/21/2017 and available online at https://federalregister.gov/d/2017-25168, and on FDsys.gov DEPARTMENT OF TRANSPORTATION National

More information

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society Guideline No.: E-03(201806) E-03 MOTORS Issued date: June 7, 2018 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements, inspection and testing

More information

SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK

SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK Truform - Description and purpose 1 Truform is structural laminated veneer lumber (LVL) intended for use as concrete formwork beams bearers,

More information

CERTIFICATE OF APPROVAL No CF 557 JOTUN PAINTS (EUROPE) LIMITED

CERTIFICATE OF APPROVAL No CF 557 JOTUN PAINTS (EUROPE) LIMITED CERTIFICATE OF APPROVAL No CF 557 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Stather Road, Flixborough,

More information

History. Quality Assurance. Applications. Protection against corrosion. Reduced installation

History. Quality Assurance. Applications. Protection against corrosion. Reduced installation 2 History The E-Klips spring steel fasteners range has been manufactured in the UK for over 25 years. Formely known as Furse Fastway they offer a quick, easy and reliable method of fixing services to steelwork

More information

Examinations of Working Places in Metal and Nonmetal Mines. AGENCY: Mine Safety and Health Administration, Labor.

Examinations of Working Places in Metal and Nonmetal Mines. AGENCY: Mine Safety and Health Administration, Labor. This document is scheduled to be published in the Federal Register on 05/22/2017 and available online at https://federalregister.gov/d/2017-10474, and on FDsys.gov 4520.43-P DEPARTMENT OF LABOR Mine Safety

More information

STATE OF NEW YORK IN ASSEMBLY

STATE OF NEW YORK IN ASSEMBLY STATE OF NEW YORK 8607 2017-2018 Regular Sessions IN ASSEMBLY July 10, 2017 Introduced by M. of A. KAVANAGH -- read once and referred to the Committee on Transportation AN ACT to amend the vehicle and

More information

CERTIFICATE OF APPROVAL No CF 681 INTERNATIONAL PAINT LIMITED

CERTIFICATE OF APPROVAL No CF 681 INTERNATIONAL PAINT LIMITED CERTIFICATE OF APPROVAL No CF 681 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Stoneygate Lane, Felling,

More information

S T A N D A R D. Copyright American Society of Agricultural and Biological Engineers. All rights reserved.

S T A N D A R D. Copyright American Society of Agricultural and Biological Engineers. All rights reserved. ANSI/ASAE S278.7 JUL03 (ISO 11001-1 1993) Agricultural wheeled tractors and implements Threepointhitch couplers Part 1: U-frame coupler S T A N D A R D ASABE is a professional and technical organization,

More information

SERVICE BULLETIN. To prevent the wing fuel boost pump wiring from chafing on the wing structure and/or fuel tube assemblies.

SERVICE BULLETIN. To prevent the wing fuel boost pump wiring from chafing on the wing structure and/or fuel tube assemblies. TITLE FUEL - WING FUEL BOOST PUMP WIRE ROUTING IMPROVEMENT EFFECTIVITY MODEL SERIAL NUMBERS 560-0001 thru -0538 REASON To prevent the wing fuel boost pump wiring from chafing on the wing structure and/or

More information