Godkjennelsesdokumenter for art. 4509, 4511
|
|
- Madlyn Hardy
- 5 years ago
- Views:
Transcription
1 Godkjennelsesdokumenter for art. 4509, 4511 Innholdsliste: Samsvarserklæring side 2 SINTEF Produktdokumentasjon side 3 Efectis Nederland BV branntestunderlag side 8 Efectis Nederland BV testrapport side 23 ELKO AS elko@elko.lxg.com Internett: Bank: Foretaksnr.: NO MVA Hovedkontor: Eyvind Lyches vei 10, NO-1338 Sandvika Postboks 234, NO-1301 Sandvika Tel: Fax: Fabrikk: Sporpind Industriområde, NO-3340 Åmot Postboks 124, NO-3341 Åmot Tel: Fax:
2
3
4
5
6
7
8 Efectis Nederland BV Return address: P.O. Box 1090, 2280 CB Rijswijk, The Netherlands Environmental Seals Ltd Envirograf House Attn: Mr. P. Ackerman-Mond Barfrestone DOVER Kent CT15 7JG UNITED KINGDOM Efectis Nederland BV Centre for Fire Safety Lange Kleiweg 5 P.O. Box CB Rijswijk T F Subject Preliminary test of Norwegian Elko sockets and Envirograf, product type 30 in a partition wall Efectis Nederland 1 report Dear Mr Ackerman-Mond, On behalf of your firm we have performed a preliminary test on a unloaded partition wall provided with several sockets. The test is based on the European standard EN :1999 and performed on January 23, The partition wall is as in practice provided with Norwegian Elko sockets and switches fitted with intumescent gaskets of Envirograf, product type 30, which expand during a fire. For this test a partition wall was prepared with Fire Line Plasterboard and only two sockets on each side. The construction is assembled at our laboratory on January 22, This report is issued by the TNO company Efectis Nederland BV (previously TNO Centre for Fire Research). TNO decided, in response to international developments and requests by customers, to collaborate with two European Egolf partners, both highly experienced in fire safety: the Norwegian Sintef/NBL and the French CTICM. Thus, through scaling up, a more comprehensive service of high quality and a wider range of facilities can be offered. In order to achieve this, the fire safety related activities of the partners involved have been privatised in this collaboration. With respect to TNO this has lead to the privatisation on the 1 st of July of the activities of the TNO Centre for Fire Research via the establishment of the company Efectis Nederland BV. Date arjo.lock@efectis.com Direct dialling (015) Direct fax (015) Project number Efectis Nederland BV: a TNO Company The Standard Conditions for Research Instructions given to Efectis, as filed at he Registry of the District Court and the Chamber of Commerce in The Hague shall apply to all instructions given to TNO; the Standard Conditions will be sent on request.
9 Date Construction details: The construction consisted of a frame with wooden studs, dimensions 100 x 50 mm with a spacing of 475 mm in the middle and 240 mm near the edges, fixed together with 100 mm screws no. 8 (see figure 1). Two layers of Fire Line Plasterboards, thickness 2 x 15 mm, on both sides, secured with galvanised clout nails, dimensions 50 x 3 mm. The construction was applied with two vertical joints at 240 mm from the edges. The dimensions of the total construction were 1450 x 1440 x 140 mm (see figure 2). 2/15 For the wall construction the following type of Norwegian Elko fitting materials were submitted: S57/100 stender hoy ring Code No 4040 S57/100 stender Code No 3012 S57/ stender Code No 4045 S57/Dobbel 4 loop stender Code No 3011 All models were provided with gaskets of Envirograf, type 30 at the bottom of the socket see photo 4. Selection of socket models From this series, two models were chosen which should present the complete series of this type of sockets. This were model S57/100 stender hoy ring and S57/Dobbel 4 loop stender The model S57/100 stender is almost the same as the S57/100 stender hoy ring with the difference that the last one is a higher model due to an extra ring to create more volume. The gasket in both models has the same surface and thickness (45 x 45 x 2.5 mm). The model S57/Dobbel 4 loop stender and the S57/ stender are both wider models with respectively 2 gaskets (45 x 45 x 2.5 mm) and 1 gasket (45 x 60 x 2.5 mm). The capacity/surface ratio of the tested models is more unfavourable than the not tested models (worse case models), see also additional letter report 2008-Efectis- R0???. At each side of the wall construction two sockets of each model where situated. The sockets were mounted onto the wooden studs and covered with the Fire Line Plasterboards. At the position of the socket a hole was drilled which was only covered with the armature cover (name???), see photo 7. Fire test: The construction was placed in front of our preliminary furnace which was equipped with three temperature sensors and a pressure device. The partition wall was applied with ten surface thermocouples at the positions showed in figure C1. The construction fulfilled the criteria for integrity and thermal insulation during the complete 90 minutes of the test.
10 The thermal insulation limits were not exceeded, all the surface temperatures stayed below 100 C. Observations during the fire test N= Non-fire side Date 3/15 Time Side Observation [min] 0 Start heating 5 N Fluctuations in furnace pressure 22 N Smoke coming from the top side of the specimen 30 N More smoke coming from the specimen 45 N Moisture visible coming out of socket B 60 N Photo of specimen after 60 minutes 63 N More moisture coming out of socket B 90 N Photo of specimen after 90 minutes 92 End of heating Assessment: A partition wall constructed of timber and covered with two layers of plasterboard and provided with Norwegian Elko sockets and switches from the tested range will have a fire resistance according to NEN 6069: 2005 of at least 90 minutes under the conditions: the timber frame has the same dimensions; Fire Line Plasterboard is used, with two layers of 15 mm at each side; the fitting materials are used mentioned in this letter report; the sockets are provided with Envirograf product 30, intumescent gaskets. At the next pages the drawings, the graphs of the test results and some photographs made during the assembly and the fire test are enclosed. Yours faithfully, A.J. Lock Dr. Ir. G. van den Berg This document has the status of a Efectis Nederland report and is known at Efectis as Efectis Nederland.-report no CVB- R0106. No part of this publication may be reproduced and/or published by print, photoprint, microfilm or any other means without the previous written consent of Efectis. In case this report was drafted on instructions, the rights and obligations of contracting parties are subject to either the Standard Conditions for Research Instructions given to TNO, or the relevant agreement concluded between the contracting parties. Submitting the report for inspection to parties who have a direct interest is permitted.
11 Date Sponsor: Environmental Seals Ltd. Project number: /15 Figure 1
12 Sponsor: Environmental Seals Ltd. Project number: Date 5/15 Figure 2
13 Sponsor: Environmental Seals Ltd. Project number: Furnace conditions Centre for Fire Safety Date: 23/01/2007 Furnace temperatures Date 6/15 Project : Wall sockets and switches Projectnbr : ISOmax ISOmin TPL1 TPL2 TPL3 Temperature [ C] ===> Time [min] ===> Graph : B1 Centre for Fire Safety Date: 23/01/2007 Deviation of the fire curve Project : Wall sockets and switches Projectnbr : ISO+ ISOdev_ISO Deviation fire curve [%] ===> Time [min] ===> Graph : B2
14 Sponsor: Environmental Seals Ltd. Project number: Centre for Fire Safety Date: 23/01/2007 Overpressure in the furnace Date 7/15 Project : Wall sockets and switches Projectnbr : Overpressure [Pa] ===> Time [min] ===> Graph : B3 Figure C1: Positions of thermocouples
15 Date Sponsor: Environmental Seals Ltd. Project number: Graphs of test results Centre for Fire Safety Date: 23/01/2007 Surfacetemperatures of the wall (part 1) 8/15 Project : Wall sockets and switches Projectnbr : Temperature [ C] ===> TC1 TC2 TC3 TC4 TC Time [min] ===> Graph : C2 Centre for Fire Safety Date: 23/01/2007 Surfacetemperatures of the wall (part 2) Project : Wall sockets and switches Projectnbr : Temperature [ C] ===> TC6 TC7 TC8 TC9 TC10 TC11 TC Time [min] ===> Graph : C3
16 Sponsor: Environmental Seals Ltd. Project number: Centre for Fire Safety Date: 23/01/2007 Ambienttemperature Date 9/15 Project : Wall sockets and switches Projectnbr : Temperature [ C] ===> Time [min] ===> Graph : C4
17 Sponsor: Environmental Seals Ltd. Project number: Photos Date 10/15 Photo 1: Assembly of sockets against wooden studs. Photo 2: Both models at fire and non-fire side.
18 Date 11/15 Photo 3: Model S57/100 stender hoy ring Photo 4: Model S57/Dobbel 4 loop stender.
19 Sponsor: Environmental Seals Ltd. Project number: Date 12/15 Photo 5: Specimen in front of furnace. Photo 6: Specimen after 60 minutes.
20 Sponsor: Environmental Seals Ltd. Project number: Date 13/15 Photo 7: Detail of socket A during test, after 60 minutes. Photo 8: Detail of socket B during test, after 60 minutes.
21 Sponsor: Environmental Seals Ltd. Project number: Date 14/15 Photo 9: Specimen after 90 minutes. Photo10: Fire side of specimen after the test.
22 Sponsor: Environmental Seals Ltd. Project number: Date 15/15 Photo 11: Detail of completely filled hole of socket A after the test. Photo 12: Detail of completely filled hole of socket B after the test.
23 Efectis Nederland BV Return address: P.O. Box 1090, 2280 CB Rijswijk, The Netherlands Environmental Seals Ltd Envirograf House Attn: Mr. D.A. Ward Barfrestone DOVER Kent CT15 7JG United Kingdom Subject Additional letter report for, product type 30 of Envirograf Efectis Nederland report R0??? 1 Dear Mr Ward, On behalf of your firm we have performed a preliminary test on an unloaded partition wall provided with two socket models as described in test report R0106/LKA/TNL. The test is based on the European standard EN :1999 and assessed according to the Dutch standard NEN 6069: To achieve information about the fire resistance aspects of the complete range of this product two models of this type of sockets were chosen and tested on January 23, The partition wall construction as described below was provided with the two models, one of each at the fire side and also at the non-fire side. 1 1 This report is issued by the TNO company Efectis Nederland BV (previously TNO Centre for Fire Research). Centre for Fire Safety Lange Kleiweg 5 P.O. Box CB Rijswijk T F Date February 26, Efectis-R0???/LKA arjo.lock@efectis.com Direct dialling (015) Direct fax (015) Project number /2008??? Efectis Nederland BV: a TNO Company The Standard Conditions for Research Instructions given to Efectis, as filed at he Registry of the District Court and the Chamber of Commerce in The Hague shall apply to all instructions given to TNO; the Standard Conditions will be sent on request. TNO decided, in response to international developments and requests by customers, to collaborate with two European Egolf partners, both highly experienced in fire safety: the Norwegian Sintef/NBL and the French CTICM. Thus, through scaling up, a more comprehensive service of high quality and a wider range of facilities can be offered. In order to achieve this, the fire safety related activities of the partners involved have been privatised in this collaboration. With respect to TNO this has lead to the privatisation on the 1 st of July 2006 of the activities of the TNO Centre for Fire Research via the establishment of the company Efectis Nederland BV.
24 Date Construction details of partition wall The wall construction consisted of a frame with wooden studs, dimensions 100 x 50 mm with a spacing of 475 mm in the middle and 240 mm near the edges, fixed together with 100 mm screws no. 8. Two layers of Fire Line Plasterboards, thickness 2 x 15 mm, on both sides, secured with galvanised clout nails, dimensions 50 x 3 mm. The construction was applied with two vertical joints at 240 mm from the edges. The dimensions of the total construction was 1450 x 1440 x 140 mm (see also the mentioned preliminary letter report) Efectis-R0???/LKA 2/2 Construction details of sockets and gaskets: All the sockets were provided with the same type of gasket. The models are used with one or with two gaskets with the following dimensions: 45 x 45 mm and 45 x 60 mm. The at the front side red coloured gasket were glued to the bottom of the socket and had a thickness of approx. 2.5 mm. The capacity of the socket models (without adapter) and the surface of the gaskets are determined and are shown in the table below. Table: 1 Norwegian socket models with Envirograf gaskets product 30 Model Code Socket surface Ratio capacity in [cm 3 ] [cm 2 ] S57/100 stender hoy ring No S57/100 stender No S57/ stender No S57/Dobbel 4 loop stender No Capacity/surface relation The determined capacity of the sockets and the surface of the gaskets show that the increase of the socket capacity is less than the surface increase of the used gasket (ratio). With thes mentioned amount of material each model of this type of sockets should be filled completely in case of a fire. Aim of the test The aim of the test set-up was to check two aspects. The sockets mounted at the nonfire and at the fire side in the mentioned type of wall and the influence of the different gaskets in the sockets. The constructions fulfill the requirements during this test.
25 Date Additional assessment * : The models of the complete range of above described Norwegian Elko fitting materials implemented in a partition wall constructed of timber and covered with two layers of plasterboard will have a fire resistance according to NEN 6069: 2005 of at least 90 minutes under the conditions: 2008-Efectis-R0???/LKA 3/3 the timber frame has the same dimensions; Fire Line Plasterboard is used, with two layers of 15 mm at each side; the fitting materials are used from this range of products; the sockets are enclosed with Envirograf product 30, intumescent gaskets with a sufficient amount of material to fill the sockets. Remark: * The construction is assessed according to the Dutch standard because only a preliminary test is performed and not a full scale test according to EN The Dutch Standard is similar with the European standard. Since 2005 the Dutch Standard refers for this type of constructions to the European standard EN Yours faithfully, A.J. Lock Dr. Ir. G. van den Berg Centre for Fire Safety This document has the status of a Efectis Nederland report and is known at Efectis as Efectis-report no Efectis-R0???. No part of this publication may be reproduced and/or published by print, photoprint, microfilm or any other means without the previous written consent of Efectis In case this report was drafted on instructions, the rights and obligations of contracting parties are subject to either the Standard Conditions for Research Instructions given to TNO, or the relevant agreement concluded between the contracting parties. Submitting the report for inspection to parties who have a direct interest is permitted.
Certifikat och provningsprotokoll för art. 4512, 4513, 4514 och 4515
Certifikat och provningsprotokoll för art. 4512, 4513, 4514 och 4515 Innehållsförteckning: Declaration of conformity... sid 2 SINTEF Produktdokumentation... sid 3 Efectis Nederland BV Brandtestunderlag...
More informationTNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F
ederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / etherlands Organisation for Applied Scientific Research TO report E 13823:22 "Single Burning Item" and E 11925-2:22 "Ignitability"
More informationOn-road emission measurements with PEMS on a MERCEDES-BENZ ATEGO Euro VI N2 heavy-duty truck
TNO report TNO 2018 R10053 On-road emission measurements with PEMS on a MERCEDES-BENZ ATEGO Euro VI N2 heavy-duty truck Anna van Buerenplein 1 2595 DA Den Haag P.O. Box 96800 2509 JE The Hague The Netherlands
More informationReport Number BTC 12024F
Report Number BTC F A FIRE RESISTANCE TEST ON A GYPROC GYPWALL PARTITION INCORPORATING A DOUBLE LAYER OF mm SOUNDBLOC EACH SIDE OF S STUDS, CONDUCTED IN ACCORDANCE WITH BS EN 4:999. Test Date: 9 th June
More informationReport Number BTC 12261F
Report Number BTC 6F A FIRE RESISTANCE TEST ON A 5m HIGH X m WIDE GYPROC SHAFTWALL SYSTEM INCORPORATING A 6mm METAL STUD FRAMEWORK CLAD WITH A DOUBLE LAYER OF 5mm GYPROC FIRELINE, EXPOSED TO THE FIRE FROM
More informationInnoBYG small scale demonstration tests - Part 2
Test report InnoBYG small scale demonstration tests - Part 2 File Serial No.: 2 Ref.: TDJ/AND Pages: 17 Enclosures: 31 2014-03-18 Date: 2014-07-09 Jernholmen 12, DK-2650 Hvidovre Phone: +45 36 34 90 00,
More informationTÜV NEDERLAND P.O. Box AC Best - The Netherlands De Waal 21C PH Best - The Netherlands +31 (0) (0)
TÜV NEDERLAND P.O. Box 120-5680 AC Best - The Netherlands De Waal 21C - 5684 PH Best - The Netherlands +31 (0)499-339500 - +31 (0)499-339539 Pendulum impact testing on double bar gate type DG-950 (UDG-37)
More informationTitle: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The fire resistance performance
More informationTitle: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: Fire resistance test in accordance
More informationPhotograph 1, Current feed to connector test loop
Photograph 1, Current feed to connector test loop Photograph 2, control conductor and instrument leads outside test chamber Page 3 of 6 Photograph 3 Salt Fog Chamber with Connector Loop Photograph 4, Connector
More informationOur firm only processes the data that is required for the preparation, implementation and completion of the case in question.
Privacy statement version of 25 May 2018 The privacy statement below implements the duty of disclosure (set out in the General Data Protection Regulation ( GDPR )) to the data subject or data subjects
More informationInnoBYG small scale demonstration tests - Part 1
Test report InnoBYG small scale demonstration tests - Part 1 File FUN0001 Serial No.: 1 Ref.: TDJ/AND Pages: 18 2013-12-11 Date: 2014-01-20 Jernholmen 12, DK-2650 Hvidovre Phone: +45 36 34 90 00, Fax:
More informationTesting of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist.
DC1333 Testing of aier Plasterboard to AS/NZS 2588 (Electronic copy (PDF format) original signed by author) Author: Neil Lee Materials Scientist Reviewer: ryan Keen Senior Technician Contact: RANZ Limited
More informationTyre noise limits of EC/661/2009 and ECE R117: Evaluation based on sold tyres in the Netherlands
Transmitted by the expert from the Netherlands Informal document GRB-60-08 (60th GRB, 1-3 September 2014, agenda item 9) M+P MBBM group People with solutions MEMORANDUM www.mplusp.eu To Attn. Ministry
More informationTest report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2015-1661
More informationNew: PREMIUM fireplaces with elevating door. Welcome to Spartherm. Why Spartherm? Models. Chamotte interior, colours
fireplaces Welcome to Spartherm The extremely high German standard of quality has helped Spartherm to evolve into the European market leader in wood-fired, elevating door fires. With more than of 55,000
More informationTitle: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:
Title: Fire Resistance Test In Accordance With BS EN 1364-1: 1999 On A Glazed Screen Assembly WF Report No: 164311, Prepared for: AGC Flat Glass Europe. Chaussee de la Hulpe 166 1170 Brussels. Date: 19
More informationTest Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3
Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 1 of 3 HONGGE (GUANGZHOU) PAPER CO., LTD BUILDING 1, HE TAI INDUSTRY ZONE, HE TAI ROAD NO.2, HE BIAN, JIA HE TOWN, BAI YUN DISTRICT, GUANGZHOU.
More informationCertRom. BUCHAREST, S5 Calea 13 Septembrie 231A; Ph: , Fax: ;
Promoting use of biofuels and bioliquids in Romania - the legal framework - Ministry of Economy and Trade and of Business Environment The 2003/30/CE Directive has been transposed into Government Decision
More informationGermany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7
Germany B1 Fire Rating kraft paper products molo design, ltd 1470 Venables Street Vancouver, B.C. Canada V5L 2G7 t +1 604 696 2501 f +1 604 685 0342 info@molodesign.com www.molodesign.com molo kraft paper
More informationIntroduction. Our Ref: Chilt/IF12041 AR1. 24 th June Astra Door Controls Ltd Unit 10 Astra Business Centre Roman Way Preston PR2 5AP
Chiltern House Stocking Lane Hughenden Valley High Wycombe Buckinghamshire HP14 4ND UK t +44 (0) 1494 569 800 f +44 (0) 1494 564895 e cif@chilternfire.co.uk w www.chilternfire.co.uk Our 24 th June 2012
More informationEnigma. Pocket sliding door systems. Wall construction preparation guide
Enigma Pocket sliding door systems 1 2 Wall construction preparation guide 3 Wall construction preparation The Enigma system can be fitted to timber or steel studwork partitions. Prior to commencing construction
More informationControlling the Speed of Tilting Trains Through Curves
Controlling the Speed of Tilting Trains Through Curves Synopsis This document mandates the means by which Tilting Trains may be operated at higher speeds than nontilting trains around curves. Signatures
More informationLIIKENNEVIRTA LTD GENERAL TERMS AND CONDITIONS FOR THE CHARGING SERVICE
1 (7) LIIKENNEVIRTA LTD GENERAL TERMS AND CONDITIONS FOR THE CHARGING SERVICE 1 Scope of application and definitions 1.1 These General Terms and Conditions pertaining to the delivery of the Charging Service
More informationWELLINGTON, NEW ZEALAND. PURSUANT to sections 152, 155(a) and (e) and 158(a)(i) of the Land Transport Act 1998
WELLINGTON, NEW ZEALAND PURSUANT to sections 152, 155(a) and (e) and 158(a)(i) of the Land Transport Act 1998 I, Gerry Brownlee, Minister of Transport, HEREBY make the following ordinary Rule: Land Transport
More informationPSTI High Induction Diffuser
PSTI High Induction Diffuser Barcol-ir is continuously aiming to optimize construction and quality for all equipment. Barcol-ir has the right to adjust the product specifications without any obligation
More informationEuropean B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd
European B1 Fire Rating soft collection softwall + softblock Fire Retardant (FR) Treated textile products molo design, ltd 1470 Venables Street Vancouver, B.C. Canada V5L 2G7 t +1 604 696 2501 f +1 604
More informationNew EU Regulation on General Safety. Implementation of Tyre Aspects
New EU Regulation on General Safety Working Paper No. STD-01-03 1st STD meeting, 23 July 2009, agenda item 2 Implementation of Tyre Aspects Presentation to joint GRB/GRRF meeting. Overview Background.
More informationFIRE TEST REPORT FH 5154
1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5154 CONE CALORIMETER TEST AND NCC SPECIFICATION C1.10
More informationyour and attach spreadsheet of 23 December 2003; and
s Science and Engineering 14 Julius Avenue, Riverside Corporate Park North Ryde NSW 2113 PO Box 310, North Ryde NSW 2113, Australia Telephone: (02) 9490 5444 Facsimile: (02) 9490 5555 ABN 41 687 119 230
More informationCALL FOR APPLICATIONS FOR THE SELECTION OF MEMBERS OF THE TACHOGRAPH FORUM
EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR MOBILITY AND TRANSPORT Directorate D - Logistics, maritime & land transport and passenger rights D.3 Road Transport Brussels, 29 January 2016 ARES (2015) 6558037
More informationStatus of the Informal Working Group on ACSF
Submitted by the IWG on ACSF Informal document GRRF-86-20-Rev.1 86 th GRRF session, 12-16 February 2018, Agenda item 9(b) Status of the Informal Working Group on ACSF Summary ACSF IWG Meeting 16th Session
More informationPRINTING OF BMI WHEELS
REQUEST FOR QUOTATIONS PRINTING OF BMI WHEELS Food and Nutrition Technical Assistance Project III (FANTA) Issue date: June 20, 2016 To: Response Deadline: June 28, 2016 Submit Questions by: June 27, 2016
More informationChemical indicators and test devices Benchmarking sterilisation processes.
Chemical indicators and test devices Benchmarking sterilisation processes www.stericlin.com Regulatory landscape National Law Directive / Regulation Guidelines Standards 2 Directive Regulation Law Guideline
More informationNo. Pr FIRE RESISTANCE TEST REPORT. Issued on: AUTHORIZED BODY AO 216. Project No: (Z )
Project No: 1 04 177 (Z210040305) AUTHORIZED BODY AO 216 TEST LABORATORY IN VESELÍ NAD LUŽNICÍ Accredited Test Laboratory - accreditation issued by the Czech Institute for Accreditation, o. p. s. Registered
More informationProposal for a new UNECE regulation on recyclability of motor vehicles
Transmitted by OICA Informal document No. GRPE-65-39 (65 th GRPE, 15-18 January 2013, agenda item 15) Proposal for a new UNECE regulation on recyclability of motor vehicles Informal Document GRPE-65-21
More informationDemonstration with optical fibres by Smart Fibres Ltd. Task 15
Demonstration with optical fibres by Smart Fibres Ltd. Task 15 Dutch Offshore Wind Energy Converter project DOWEC 10021 rev1 Name: Signature: Date: Written by: J.F. Kooij (LMGH) 30-09-03 version Date No
More informationImplementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E
1. Scope 1.1 The general process is described in the implementation procedure for design approvals of aircraft, engine and propeller from CIS and in the implementation procedure for design approvals of
More informationSound-absorbing spacer Sorp10
Sponsor: Reference number: 7.3 / 27080 This document is only a translated version; not legally attested Max Frank GmbH & Co. KG Mitterweg 1 94339 Leiblfing Federal Institute for Materials Research and
More informationISO :2015/DAM 1
DRAFT AMENDMENT ISO 19973-2:2015/DAM 1 ISO/TC 131 Voting begins on: 2018-01-15 Secretariat: ANSI Voting terminates on: 2018-04-09 Pneumatic fluid power Assessment of component reliability by testing Part
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires
Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular
More informationElectric Vehicles and the Environment (EVE IWG)
Submitted by the EVE informal working group Electric Vehicles and the Environment () 1 Informal document GRPE-77-28 77 th GRPE, 6-8 June 2018 Agenda item 9 REPORT TO GRPE 77 TH SESSION Current Mandate
More informationOPW Fluid Transfer Group Europe BV
Manual OPW Fluid Transfer Group Europe BV Tank Truck Tester 1397E & 1398E Disclaimer With this document an user manual is presented of the OPW tank-truck-tester 1397E & 1398E and is designed to use in
More informationTHE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-23R Extension number: 00
Vehicle Technology Division THE NETHERLANDS (N E D E R L A N D) COMMUNICATION Concerning (1) : - approval granted - approval extended - approval refused - approval withdrawn - production definitely discontinued
More informationElectric Vehicles and the Environment (EVE IWG)
Submitted by the EVE informal working group Electric Vehicles and the Environment () 1 Informal document GRPE-78-30-Rev.1 78 th GRPE, 10-11 January 2018 Agenda item 9 REPORT TO GRPE 78 TH SESSION Original
More informationE/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1
30 August 2011 Agreement Concerning the adoption of uniform technical prescriptions for wheeled vehicles, equipment and parts which can be fitted and/or be used on wheeled vehicles and the conditions for
More informationTest report no
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2014-1452-2
More informationTest report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1940
More informationTitle: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A
Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN 1634-1: 2000 Report No: 163712 A Prepared for: Novoferm GmbH Haldern Isselburger Str.
More informationAIRBUS EASA AD activities AD implementation
E. BLANCANEAUX A318/19/20/30 HO continued airworthiness A. PANNIER A330/A340 Cont airworthiness manager Presented by: AIRBUS EASA AD activities AD implementation 10 th EASA 3th workshop - Airbus Airbus-
More informationTitle: WF Report No:
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance
More informationCOMMISSION REGULATION (EC)
L 191/26 Official Journal of the European Union 23.7.2009 COMMISSION REGULATION (EC) No 640/2009 of 22 July 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard
More informationTest report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2016-1390
More informationVersion / Status V 2.0 Date Author. Wagon Markings
1. Introduction Wagon Markings Article 4, para 4 of the Safety Directive (2004/49/EG amended by 2008/110/EC) stipulates the responsibility of each manufacturer, maintenance supplier, wagon keeper, service
More informationTHE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY
THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY COMMUNICATION CONCERNING THE APPROVAL GRANTED (1) TO A COMPONENT TYPE- APPROVAL CERTIFICATE IN RESPECT OF A NON-ORIGINAL EXHAUST SYSTEM FOR A TYPE OF MOTORCYCLE
More informationOfficial Journal of the European Union. (Non-legislative acts) REGULATIONS
10.1.2019 L 8 I/1 II (Non-legislative acts) REGULATIONS REGULATION (EU) 2019/26 OF THE EUROPEAN PARLIAMT AND OF THE COUNCIL of 8 January 2019 complementing Union type-approval legislation with regard to
More informationTown of Centreville Automated Speed Enforcement Program
Frequently Asked Questions: Town of Centreville Automated Speed Enforcement Program What is Automated Speed Enforcement In October 2009 the State of Maryland authorized the use of Automated Speed Monitoring
More informationEDS: AN EUROPEAN STUDY FOR NEW DEVELOPMENTS IN AUTOMOTIVE TECHNOLOGY TO REDUCE POLLUTION
EDS: AN EUROPEAN STUDY FOR NEW DEVELOPMENTS IN AUTOMOTIVE TECHNOLOGY TO REDUCE POLLUTION Prof. Dr. Ir. G. Maggetto Ir. P. Van den Bossche Vrije Universiteit Brussel Brussels, Belgium Abstract The study
More informationTECHNICAL AND OPERATIONAL DOCUMENTATION
Ver. PL1 10.04.08 ul. Grzegorza z Sanoka 2 80 408 Gdańsk tel. +48 58 341 42 45 TECHNICAL AND OPERATIONAL DOCUMENTATION Overpressure-bleed damper of mcr PL1 type FIRE VENTILATION SYSTEMS DEPARTMENT GDAŃSK
More informationAdministrative Circular TO ALL NATIONAL COMMITTEES. Dear Sir/Madam, Co-operation and Licence Agreement between IEC and IEEE
Administrative Circular 138/AC 2002-12-13 TO ALL NATIONAL COMMITTEES Dear Sir/Madam, Co-operation and Licence Agreement between IEC and IEEE Further to document C/1257A/RV and the decision on Council Document
More informationJUDGMENT OF THE COURT (Sixth Chamber) 2 June 1994 *
VAN SWIETEN JUDGMENT OF THE COURT (Sixth Chamber) 2 June 1994 * In Case C-313/92, REFERENCE to the Court under Article 177 of the EEC Treaty by the Arrondissementsrechtbank, Amsterdam (Netherlands), for
More informationISO INTERNATIONAL STANDARD. Measurement of noise emitted by accelerating road vehicles Engineering method Part 2: L category
INTERNATIONAL STANDARD ISO 362-2 First edition 2009-07-15 Measurement of noise emitted by accelerating road vehicles Engineering method Part 2: L category Mesurage du bruit émis par les véhicules routiers
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 1.3 CURVE SQUEAL OF
More informationAmsterdam Boats. High-quality luxury boats and hospitality. Conditions of use and disclaimer. Version: August 2018
High-quality luxury boats and hospitality Conditions of use and disclaimer Version: August 2018 B.V. Registered with the Chamber of Commerce under number: 34331505. Established at the Cruquiusweg 40 in
More informationFlowBar High Capacity Slot Diffuser
October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections
More informationTEST REPORT CONCERNING THE COMPLIANCE OF A VOTING MACHINE FOR USE AT ELECTIONS IN IRELAND, BRAND NEDAP, MODEL P.R.U
Testing and certification of electric, electronic and radio equipment/installations including telecommunication systems TEST REPORT CONCERNING THE COMPLIANCE OF A VOTING MACHINE FOR USE AT ELECTIONS IN
More informationPMA Parts and Approved Repairs Issues in Europe
PMA Parts and Approved Repairs Issues in Europe Pieter Ruitenberg San Diego, CA, USA 2009 ADSE B.V. 1 Introduction Outline EASA; Changes in the regulations EASA changes to PMA approvals EASA / FAA Order
More informationDeclaration naming Richard J. Nixon and Dale Brand under section 106 of the Oil and Gas Conservation Act
November 30, 2017 By email and registered mail To: Richard J. Nixon Dale Brand Declaration naming Richard J. Nixon and Dale Brand under section 106 of the Oil and Gas Conservation Act Dear Messrs. Nixon
More informationSEM.Test Compliance Service Co., Ltd
TEST REORT ST/SG/AC.10/11 Rev.5 Section 38.3 AMEDMETS TO THE FIFTH REVISED EDITIO OF THE RECOMMEDATIOS O THE TRASORT OF DAGEROUS GOODS, MAUAL OF TEST AD CRITERIA (Section 38.3: Lithium batteries) Report
More informationADDINOL Eco Gear Longlife x 4 Long-term warranty. Longlife. Guarantee
ife x 4 ADDINOL Eco Gear Longlife x 4 Long-term warranty Longlife Guarantee Long-term warranty terms For ADDINOL Eco Gear M and S ADDINOL guarantees a service life of four years in industrial gears and
More informationReport No.: STR S. ST/SG/AC.10/11 Rev.5/Amend.2 Section 38.3
TEST REORT ST/SG/AC.10/11 Rev.5/Amend.2 Section 38.3 AMENDMENTS TO THE FIFTH REVISED EDITION OF THE RECOMMENDATIONS ON THE TRANSORT OF DANGEROUS GOODS, MANUAL OF TEST AND CRITERIA (Section 38.3: Lithium
More informationOverhead transmission lines Spacers
= SVENSKA KRAFTNÄT SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AEL, Asset Management Lines OUR REFERENCE TR05-08E DATE 2016-06-09 CONSU12TATIONS TECHNICAL GUIDELINE REVISION 3 APPROVED Overhead transmission
More informationAustralian Standard. Pneumatic fluid power General requirements for systems (ISO 4414:1998, MOD) AS AS 2788
AS 2788 2002 AS 2788 Australian Standard Pneumatic fluid power General requirements for systems (ISO 4414:1998, MOD) This Australian Standard was prepared by Committee ME-035, Fluid Power Systems and Components.
More informationAlberta Electric System Operator Saleski Transmission Project Needs Identification Document
Decision 2013-127 Alberta Electric System Operator Saleski Transmission Project Needs Identification Document ATCO Electric Ltd. Saleski 901S Substation and 144-kV Transmission Line 7L142 Facility Application
More informationECOMP.3.A EUROPEAN UNION. Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 ENT 229 MI 914 ENV 837 AGRI 596 PREP-BXT 58 CODEC 2164
EUROPEAN UNION THE EUROPEAN PARLIAMT THE COUNCIL Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 T 229 MI 914 V 837 AGRI 596 PREP-BXT 58 CODEC 2164 LEGISLATIVE ACTS AND OTHER INSTRUMTS
More informationspecifying the applications each has before the AER and the AER licences and approvals such licensee or approval holder holds.
DECLARATION NAMING ALEXANDER JUSTIN VON GRAMATZKI, FORMERLY KNOWN AS ALEXANDER JUSTIN HANNE, PURSUANT TO SECTION 106(1) OF THE OIL AND GAS CONSERVATION ACT For the reasons set out in the accompanying letter,
More informationThe oil fields in the NCS are located in the North Sea, Norwegian Sea, and Barents Sea.
A.2 Norway Volumes of Associated Gas Flared on Norwegian Continental Shelf Norway is a major oil producer, and its oil fields are located offshore in the Norwegian Continental Shelf (NCS). 81 In 2002,
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 8178-4 Second edition 2007-12-15 Reciprocating internal combustion engines Exhaust emission measurement Part 4: Steady-state test cycles for different engine applications Moteurs
More informationLithium Battery UN38.3 Test Report
Lithium Battery UN38.3 Test Report Prepared For : Samples Name: Model : Prepared By : Report No.: Shenzhen Haomingshe Electronic Technology Co., Ltd. 2F, Building E, Huachuangda Industrial Park, Hangcheng
More informationCavity Stop Socks & TCBs
MANAGEMENT V3 27.04.2015 Cavity Stop Socks & TCBs Key Features Up to four hours fire integrity Specified in semi-detached, apartments and major projects Complies to Robust Detail Part E and Building Regulations
More informationISO INTERNATIONAL STANDARD. Gas turbines Procurement Part 3: Design requirements
INTERNATIONAL STANDARD ISO 3977-3 Second edition 2004-08-15 Gas turbines Procurement Part 3: Design requirements Turbines à gaz Spécifications pour l'acquisition Partie 3: Exigences de conception Reference
More informationNATIONAL HOMOLOGATION FORM KARTING ENGINE
NATIONAL HOMOLOGATION FORM KARTING ENGINE Manufacturer TORINI MOTOR CO., LTD. Make TORINI Model CLUBMAXX 210 (TC210) Validity of the homologation 6 years Number of pages 34 Homologation N This Homologation
More informationTrain Safety Systems. Railway Group Standard GM/RT2185 Issue Two Date December 2001
Train Safety Systems Synopsis This document defines the requirements for train safety systems to enable safe operation of trains on Railtrack controlled infrastructure. Signatures removed from electronic
More informationTEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors
r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of
More information10-Feb-14. VCA job number: CSP Date: 10 February Dear Sirs,
VCA job number: CSP286498 Date: 10 February 2014 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC
More informationA SHORT HISTORY SINCE DIESELGATE. Richard Smokers
A SHORT HISTORY SINCE DIESELGATE Richard Smokers Symposium Vehicle Emissions November 3, 2016 TEST PROGRAMMES AT TNO Since 1986 in a sequence of projects for the Dutch Ministry of Infrastructure and the
More informationLithium Battery UN38.3 Test Report
Lithium Battery UN38.3 Test Report Prepared For : Samples Name: Model : Prepared By : Report No.: Allfine Lithium Energy (Hefei) Co., Ltd. Building 12, Mechatronics Industrial Park, Fengle Road, Hefei
More informationNATIONAL HOMOLOGATION FORM KARTING ENGINE
NATIONAL HOMOLOGATION FORM KARTING ENGINE Manufacturer TORINI MOTOR CO., LTD. Make TORINI Model TC250 (PREVIOUSLY TRE220) UPDATE Validity of the homologation 6 years Number of pages 35 This Homologation
More informationTest report No
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1031
More information3000ZR PRECISION VOLTAGE REFERENCE 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS
3000ZR PRECISION VOLTAGE REFERENCE 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS 3000ZR Series Precision Voltage Standard Operation Manual Version 3.00 Aug 2013 All product names are trademarks
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 10924-1 Second edition 2016-04-01 Road vehicles Circuit breakers Part 1: Definitions and general test requirements Véhicules routiers Coupe-circuits Partie 1: Définitions et
More informationTest report no
Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2015-1339
More informationCurrent and planned policies on drink-driving & drug-driving. Desirée Schaap Projectleader alcolockprogram
Current and planned policies on drink-driving & drug-driving Desirée Schaap Projectleader alcolockprogram 06 July 2009 Last ten years a reduction of 30 % Fatalities per year number 4000 3500 3000 2500
More information11-Feb-14. VCA job number: CSP Date: 11 February Dear Sirs,
VCA job number: CSP286503 Date: 11 February 2014 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC
More informationSubject - Revisions to PG&E Forms Entitled General Terms and Conditions (Form ) and Declarations (Form ).
May 11, 2001 ADVICE 2316-G/2116-E (Pacific Gas and Electric Company ID U 39 M) Subject - Revisions to PG&E Forms Entitled General Terms and Conditions (Form 79-716) and Declarations (Form 62-0980). Public
More informationThorsten Wege. 4th ISCC Global Sustainability Conference in Brussels on 5th February 2014
Thorsten Wege 4th ISCC Global Sustainability Conference in Brussels on 5th February 2014 6 Februar 2014 Thorsten Wege - Biofuel policy coordinator (head of a small unit) - Chair of int. working group biofuels
More informationWF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The fire resistance performance
More informationQUESTION / CLARIFICATION
QUESTION / CLARIFICATION CO-ORDINATION BETWEEN NOTIFIED BODIES INTEROPERABILITY DIRECTIVE AND SUBSEQUENT AMENDMENTS ON THE INTEROPERABILITY OF THE RAIL SYSTEM WITHIN THE UNION QC-RST-020 Issue 02 Date:
More informationLithium Battery UN38.3 Test Report
Lithium Battery UN38.3 Test Report Prepared For : Samples Name: Shenzhen Pu Sheng Power Supply Technology Co., LTD. Rm501, 5F, Jinsheng Industrial Zone, No.109, HuDiPai, DaFu, GuanLan Town, LongHua New
More information} Rev.1/Add.52/Rev.2/Amend.2
19 February 2010 AGREEMENT CONCERNING THE ADOPTION OF UNIFORM TECHNICAL PRESCRIPTIONS FOR WHEELED VEHICLES, EQUIPMENT AND PARTS WHICH CAN BE FITTED AND/OR BE USED ON WHEELED VEHICLES AND THE CONDITIONS
More information