255 Valve Specifications
|
|
- Cecily Booker
- 5 years ago
- Views:
Transcription
1 255 Valve Specifications imagation at work
2 Specifications low Rates (Valve Only) 15 psi (1.03 ) drop (3.52 m 3 /h) 25 psi (1.72 ) drop (1.36 m 3 /h) Service v = 3.99 (v = 3.4) ackwash v = (v = 1.0) Note: Tested with a 3/4-ch brass manifold Valve onnections/imensions Tank Thread nlet/outlet Manifold (rass or Noryl ) ra Le re Le istributor Tube iameter istributor Tube Length /2-ches 8, male 1-ch NPT or SPT, female 3/4-ch NPT or SPT, female 3/4-ch NPT or SPT, male, Noryl 1/2-ch NPT or SPT, male, Noryl 1/2-ch (manifold dependent) 1/4-ch or 3/8-ch NPT, male; air check built to valve ches (27 mm) or 13/16-ch (20.6 mm) 1-1/8 ± 1/8 ches (29 mm ± 3 mm) above top of tank esign Specifications/Ratgs Valve ody lass-filled Noryl NS listed material Rubber omponents ompounded for cold water NS listed materials Valve Materials ertification NS/ANS 44 rated component for material safety Weight (Valve with ontrol) bs (1.8 kg) Recommended Operatg Pressure psi ( ) anada psi ( ) ydrostatic Test Pressure psi (20.69 ) Water Temperature (2-38 ) Ambient Temperature* ( ) *Recommended use of outdoor cover for direct sunlight applications Options Turbe for emand Units ypass Valve ypass nlet-outlet ittg its: opper, Sweat Tube Adapter PV, Solvent Weld Tube Adapter Plastic NPT or SPT Pipe Adapter rass NPT or SPT Pipe Adapter re Refill ontrols ompatible with Regenerants/hemicals Standard manifold, 1-ch Autotrol turbe Noryl, 1-ch flow path, 1/2-ch (13mm) NPT male, dra 1-ch or 3/4-ch (25 mm or 19 mm) 1-ch or 3/4-ch (25 mm or 19 mm) 1-ch male or 3/4-ch male (25 mm or 19 mm) 1-ch male or 3/4-ch male (25 mm or 19 mm).33 (1.25 Lpm) fixed.17 (.64 Lpm) fixed optional for small tank applications 1-10 lbs ( kg) 400 series controllers 3-19 lbs ( kg) 400 series controllers Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide, hydrochloric acid, chlore and chlorames See owners manual for specific concentrations Valve for use on potable water supply 2
3 njector* Performance Logix Series ontrollers 0.35 njector (Peach) or 7-ch Tanks 0.11 njector (Tan) or 8-ch Tanks LWR6057 LWR njector (Light Purple) or 9-ch Tanks 0.18 njector (Light lue) or 10-ch Tanks LWR6151 LWR6151 njector (Pk) or 12-ch Tanks njector L (Orange) or 13- and 14-ch Tanks LWR6151 LWR6164 *New jectors for high-efficiency regeneration sequence are standard with Logix ontrollers. NOT: Actual jector performance is dependent on the res used, tank geometry, elevated dra, etc. This jector data was taken usg an empty tank (no res). 3
4 400 and 900 Series ontrollers low Rate haracteristics njector A (White) psi LWR4669 P R S S U R R O P m 3 /h AWAS LOW v = 255 SRV LOW v = 3.99 LWR 5236 W LWR 4630 SV L O W R A T njector (lue) LWR4669 ackwash low ontrol Table ackwash low Rate low Rate Number** () (lpm) **ackwash flow controls sized for 5.0 /ft njector (Red) LWR4669 4
5 ontroller Series offers a full range of valve controllers to meet all residential water-conditiong applications. Logix Series 740 Time lock Simple, economic electronic time clock (chronometric) 7- or 99-day regeneration settg igh efficiency regeneration sequence 12-volt operation ilter or conditioner settg one control Operates 255, 263, 268 with one controller 742 Time lock Same features as the 740 time clock, plus: ully programmable cycle times Salt settg 1-pound crements Optional no-salt detector Operates 255, 263, 268, 278, and Magnum T with one controller 760 emand Simple, economic electronic demand (volumetric) alendar override 12-volt operation 28-day variable reserve igh efficiency regeneration sequence Automatic capacity calculations Operates 255, 263, 268 with one controller 762 emand Same features as the 760, plus: ully programmable cycle times Salt settg 1-pound crements Optional no-salt detector Operates 255, 263, 268, 278, and Magnum T with one controller 400 Series 440i Time lock Value priced, reliable mechanical control Time-clock regeneration Set it and forget it 12-volt or 120-volt versions available 6- or 7-day regeneration Operates 255, 263, 268 valves lectrical Specifications ontroller Operatg Voltage nput Supply requency Motor nput Voltage lectronics Operatg Voltage (Logix Series) ontroller System Power onsumption 12 Volt A (Requires use of nfrastructure supplied transformer) 50 or 60 z (ontroller configuration dependent) 12 Volt A 3.5 Volt A 3 Watts average 460i Time lock conomical electronicdemand control Simple set-up and programmg alendar override 12-volt operation 7-day variable reserve Operates 255, 268 valves Transformer Specifications All ontrollers All ontrollers require the use of a nfrastructure supplied transformer. Transformer Output Voltage Transformer nput Options Transformer Plug Options 12 Volt A 400mA 115 Volt A 50/60 z; 230 Volt A 50/60 z; 100 Volt A 50/60 z ndoor North American Plug Outdoor North American (UL Listed for outdoor use) apanese Plug Taiwan/orea Plug Australian Plug United gdom Plug Maland urope Plug Additional transformers may be available call for more formation 5
6 ontroller valve manufactured by: North American Sales 5730 N. len Park Road Milwaukee, W USA (262) Phone (262) ax or More nformation: all nfrastructure Water & Process Technologies; ousehold Water roup at (262) or (800) , or visit Valve Outle imensions Logix Series ontrollers 400 Series ontrollers 255 Valve imensions with Logix over 255 Valve imensions with 400 Series ontroller A nlet ra Outlet A L 255 Valve Logix Series ontroller A (37.8) (16.8) (20.8) (21.3) (10.7) (10.2) (34.5) (7.9) (13.0) M 255 Valve 400 Series ontroller A (30.6) (12.2) (13.8) (22.5) (8.9) (16.5) L (23.8) (21.8) (2.4) (11.6) imagation at work 2005, eneral lectric ompany. Prted USA, P/N Rev.
Performa Valve Specifications. 263 and 268 Configurations. imagination at work
erforma Valve pecifications 263 and 268 Configurations imagation at work pecifications Flow ates (Valve Only) Logix and 900 eries Controllers ervice @ 15 psi (1.03 ) drop....................... 25.0 (5.7
More information255 Valve Specifications
255 Valve Specifications imagination at work Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop... 15.5 (3.52 m 3 /h) Backwash @ 25 psi (1.72 ) drop... 6.0 (1.36 m 3 /h) Service... Cv=3.99
More informationPerforma Valve Specifications. 263 and 268 Configurations. imagination at work
erforma Valve pecifications 263 and 268 Configurations imagination at work pecifications Flow ates (Valve Only) Logix and 900 eries Controllers ervice @ 15 psi (1.03 ) drop... 25.0 (5.7 m 3 /h) Backwash
More informationSpecifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation
Specifications GE Osmonics Autotrol 255 Series Valve Specifications Series Controllers Flow Rates (Valve Only) Service @ 15 psi (1.03 bar) drop 15.5 gpm (3.52 m 3 /h) Backwash @ 25 psi (1.72 bar) drop
More informationTECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL
TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TIMER CHARACTERISTICS 742 TIME CLOCK Electronic time clock (chronometric)
More informationMagnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work
Magnum Cv Valve Specifications Magnum IT and Standard Configurations imagination at work Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop....................... 76 (17.3 m 3 /hr) Backwash
More informationCOMMERCIAL CONTROL VALVES. Magnum Control Valve
COMMERCIAL CONTROL VALVES Magnum Control Valve COMMERCIAL CONTROL VALVES Magnum Control Valve Controller Options The Pentair Water Magnum Control Valve is one of the most versatile valves on the market.
More informationwd-2
wd-2 wd-4 wd-5 wd-6 wd-7 wd-8 wd-9 wd-10 wd-11 wd-12 wd-13 Part # Tank Size ( DxH ) Media Volume (ft3) Service Flow Rate (GPM) WD SP35BFJCT 10 x44 1.0 6.0 WD SP46BFJCT 10 x54 1.5 9.0 WD SP56BFJCT 10 x54
More informationControl Valves, Fittings and Accessories
Control Valves, Fittings and Accessories NEW WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SP 70 gpm WS2EE WS2SP 115 gpm WS2EE/QC* WS2SP/QC* 125 gpm WS1.25* WS1.25CS*
More informationControl Valves, Fittings and Accessories
Control Valves, Fittings and Accessories NOW WITH BATTERY PACK OPTION WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SD/SP 70 gpm WS2EE WS2SD/SP 115 gpm WS2EE/QC* WS2SP/QC*
More informationAUTOTROL 742/762 CONTROL 255 & PERFORMA SERIES VALVES (263, 268, 268 FA)
AUTOTROL 742/762 CONTROL 255 & PERFORMA SERIES VALVES (263, 268, 268 FA) SERVICE MANUAL www.pentairaqua.com TABLE OF CONTENTS MANUAL OVERVIEW...2 SAFETY INFORMATION...2 CALIFORNIA PROPOSITION 65 WARNING...2
More information5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.
Brine Well Distributor Tube and basket Safety-Cut Off (Optional) $8.00 extra Air Check Assembly Over-Flow (Optional) $1.00 extra 5600 Control Valve Gravel (Optional) Bypass Piping Boss Inlet & Outlet Brine
More informationOperation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:
Operation Manual 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer: Your local dealer is: TABLE OF CONTENTS LOGIX SERIES INSTALLER QUICK-START
More informationHMF, SMF & BMF Media Filters
TM ilters M, SM & M Media ilters Pre-engineered V iltration Solutions Self-cleaning, packaged filter systems designed to save you time and money flow rates filtration degrees inlet/outlet diameter operating
More information* Optional PRESSURE COMPENSATOR - FLANGED TYPE B A X 2.2. Typical application VR5P with flow control valve
* Veljan 3 ports pressure compensator Valve are designed for improved operation safety and reduced mountg cost. These valves are used to mata a constant pressure drop External PD, External PP Internal
More informationAgency Air-Inert Gas Water. Approx. Shipping Weight (lbs.) 1/2 5/ P Brass. Const.
NXT NRATON lectronically nhanced Solenoid Valves rass and odies 1/" - 2" NPT 2/2 3/2 /2 eatures ncrease in pressure ratings to A levels on all products (up to a 500% improvement) Lower power operation
More informationOperation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:
Operation Manual 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer: Your local dealer is: TABLE OF CONTENTS LOGIX SERIES INSTALLER QUICK-START
More informationWater Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS
Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the
More informationThe Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C
ulletin 617 Rev. Model R ommercial Riser Riser Manifold for ommercial pplications ulletin 617 Rev. vailable Sizes/Pressure Ratings: 1 1 / 2 (40mm) and 2 (50mm) Threaded - 250 psi (17,2 bar) Working Pressure
More informationSuperior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770
Superior Water And Air 80-974-9090 800-974-7638 OWNER S MANUAL Model 32-CL770 & 48-CL770 GENERAL INFORMATION Congratulations on having purchased a quality and well built Superior Water Softener. On a normal
More informationWater Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI
Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the
More informationSV321 & SV Way Normally Closed and Normally Open Pilot Operated Solenoid Valves
SV321 & SV421 2-Way and Pilot Operated Solenoid Valves Valcor General Purpose Series ESRIPTION pplication Features These 2-way piloted diaphragm solenoid valves are available in normally closed and normally
More informationB352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem
352, 3-Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.
More informationF6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
6100H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions
More informationTu-Wire Overview. Fluorescent Dimming Ballasts Tu-Wire 5% High-Performance Dimming
Overview Tu-wire ballasts are primarily intended for retrofit applications where fluorescent dimming must be achieved without changing the existing switching wiring scheme. Tu-wire ballasts require only
More informationOperation Manual. 742/762 Control 255 and Performa Series Valves (263, 268, 268FA) For Sales & Service questions please contact your dealer:
Operation Manual 742/762 Control 255 and Performa Series Valves (263, 268, 268FA) For Sales & Service questions please contact your dealer: Your local dealer is: TABLE OF CONTENTS LOGIX SERIES INSTALLER
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.
Level Measurement Pointek LS200 Standard Siemens A 20 Overview onfiguration Installation Pointek LS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable
More informationSection 8. Copper Series
Section 8 opper Series Grooved ouplgs, Fittgs & omponents for opper Tubg... 164 Pressure Ratgs of opper Tubg... 164 Standard Roll Groove for U.S. Standard opper Tubg... 164 Grooved ouplgs & Flanges for
More informationG765, 3-Way, Mixing Flanged Globe Valve
G765, 3-Way, Mixing langed Globe Valve pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable
More informationHigher DC pressure rating 80% reduction in power consumption Built-in surge suppression 3-year coil warranty Class I, Division 2 coils available
4 igher pressure rating 80% reduction in power consumption uilt-in surge suppression 3-year coil warranty lass, ivision 2 coils available Redat Next eneration lectronically nhanced Solenoid Valve Technology
More informationG6125C, 2-Way, Pressure Compensated Flanged Globe Valve
G6125, 2-ay, Pressure ompensated langed Globe Valve pplication This valve is typically used in large air handling units on heating or cooling coils. This valve is suitable for use in a hydronic system
More informationWS1 & 1.25 Man u al. Introduction. The following general warnings and the specifications in Table 1 must appear in the OEM s System Manual.
Page 4 WS1 & 1.25 Man u al Introduction This manual is about a control valve to be used on water softeners or water filters. The manual is designed to aid water treatment equipment manufacturers in the
More informationCALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function
HydroMixer direct distribution unit for heating systems 6 series REDITED LEI ISO 900 M 6 ISO 900 No. 000 07/ N unction The 6 series HydroMixer TM provides high temperature flow direct to secondary heating
More informationAgency Air-Inert Gas Water. Approx. Shipping Weight (lbs.) 1/2 5/ P Brass. Const.
NXT NRATON lectronically nhanced Solenoid Valves rass and Stainless Steel odies 1/" - 2" NPT 2/2 3/2 /2 SRS eneration eatures ncrease in pressure ratings to A levels on all products (up to a 500% improvement)
More informationWater Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25
Water Specialist Control Valve Series Model: WS.25 Control Valve Series Model: WS.25 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More information740/760 Control 255 and Performa Series Valves (268, 268FA)
740/760 Control 255 and Performa Series Valves (268, 268FA) Operation Manual For Sales & Service questions please contact your dealer: Your local dealer is: TABLE OF CONTENTS LOGIX SERIES INSTALLER QUICK-START
More informationAccessories. UP timer. Timer control. Approvals. UP Series
UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval Size: 3.77 x 2.85 x 1.25" Supply voltage: 120 VC Power consumption: 1 V Switch rating: SPT Resistive:
More informationF6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
6125H, 5, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications
More informationFoam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS
FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75 quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed
More informationFoam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS
FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75" quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed
More informationSJ-300N J-04. Model SJ-300N-L Butterfly Valve with Lever Handle
SJ-300N J-04 MODEL SJ-300N BUTTERFLY VALVE The Model SJ-300N Butterfly Valve is a grooved-end tight shut-off valve designed, manufactured and tested to MSS SP-67. The valve can be shipped either with a
More informationB278, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem
28, 2-Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.
More informationAmphenol Amphenol Pcd Terminal Junction Systems
igh Quality Interconnect Products or Military and erospace pplications mphenol mphenol Pcd Terminal unction Systems Terminal unction Systems MIL-T-171 Series I lass MIL-T-171 Series I unction Modules QPL-approved
More informationYour Global Source for Today s Most Popular Solenoid Valves
lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International
More informationModel WS1 Demand. Operation & Maintenance Manual. 114 Vista Parkway Avon, IN New Aqua L.L.C.
Model WS1 Demand Operation & Maintenance Manual 114 Vista Parkway Avon, IN 46123 317-272-6721 2008 New Aqua L.L.C. Page 2 Quick Reference Chart GENERAL OPERATION When the system is operating one of two
More informationG765, 3-Way, Mixing Flanged Globe Valve
pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable flow. Suitable ctuators Non-Spring
More informationG780, 3-Way, Mixing Flanged Globe Valve
G780, 3-Way, Mixing langed Globe Valve pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable
More informationSJ-300N. Model SJ-300N-L Butterfly Valve with Lever Handle Max. Working Pressure (CWP)* PSI Bar Dimensions A B C D E in.
SJ-N MODEL SJ-N BUTTERFLY VALVE The Model SJ-N Butterfly Valve is a grooved-end tight shut-off valve designed, manufactured and tested to MSS SP-67. The valve can be shipped either with a -position lever
More informationN Series. High Speed Inline Poppet Valves 2 & 3-Way. Section D
Series igh Speed Inline Poppet Valves & 3-Way Section www.parker.com/pneu/n X Viking Z asic Valve unctions...0 Series asic eatures... ommon Part umbers...-3 Model umber Index...4- Technical Information
More informationPresentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508
Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:
More informationF6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications
More informationWater Specialist 1 Control Valve Series Model: WS1TC 1.25 Control Valve Series Model: WS1.25TC
Water Specialist Control Valve Series Model: WSTC.25 Control Valve Series Model: WS.25TC Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More informationZurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications
Zurn Wilkins ire Protection Series ackflow Preventers, Pressure Regulating Valves, and Water ontrol Products for ire Sprinkler pplications Zurn Wilkins ire Protection Series Zurn Wilkins fire protection
More informationFLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL
FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL 2013 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 INSTALLATION... 3 START-UP INSTRUCTIONS...
More informationPILOT OPERATED SEQUENCE VALVE - Series VR4S
PILOT OPERTED SEQUENCE VLVE - Series VRS Veljan Sequence Valve Series VRS are pilot operated controls and enable a hydraulic system to operate a sequence. Fluid is allowed to pass to a secondary system
More informationVic -300 Butterfly Valves
R IPS RON STL PIP GROOV VLVS Vic -300 utterfly Valves 08.02 VITULI IS N ISO 9001 RTII OMPNY PROUT SRIPTION Vic -300 butterfly valves are designed for pressures ranging from vacuum to 300 psi (2065 kpa).
More informationCOMMERCIAL / INDUSTRIAL WATER SOFTENERS
COMMERCIL / INDUSTRIL WTER SOFTENERS When performance & value matters. CONTROL VLVES SPECIFICTIONS EWS1 EWS1.5 EWS2QC Service @ 15 psi drop ackwash @ 25 psi drop 27 gpm (includes meter & bypass) 27 gpm
More informationVB2, VB3 Ball Valve/Actuator Assemblies
V2, V all Valve/ctuator ssemblies TURS PROUT T V2 V V2 ll Models Sizes from 1/2 in. to 2 in. with internal nominal pipe thread (NPT) connections. qual Percentage flow characteristics. ield configurable
More informationFLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL
FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 INSTALLATION... 3 START-UP INSTRUCTIONS... 4 CONTROL FEATURES... 4 CONTROL OPERATION...
More informationG7100S, 3-Way, Mixing Flanged Globe Valve
pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable flow. Suitable ctuators Non-Spring
More informationModel ZW204 Non-Modulating Float Valve
Model Z04 Non-Modulating loat Valve pplication The Zurn ilkins Model Z04 Non-Modulating loat Operated ontrol Valve is designed to be either fully open or fully closed in response to the position of the
More informationPHOTOSWITCH Liquid Level and Resistance Sensing Control Bulletin 13DJ3-3000
Liquid Level and Resistance Sensing Control Bulletin 3DJ3-3000 Product Data Description Features The Photoswitch Bulletin is a high sensitivity Liquid Level Control designed to detect the level of conductive
More informationCommercial Softeners
Commercial Softeners Product Index Page General System Specifications 35 Fleck Commercial Valve Configurations 36 Fleck 9500 1-1/" Systems 37 Fleck 850 1-1/" Systems 38 Fleck 3150 " Systems 39 Fleck 900
More information2/2. Air or Water Pilot Operated Angle Body Multi-Purpose Valves. Bronze or 316L Stainless Steel Bodies 3/8" to 2 1/2" NPT.
4 Air or Water Pilot Operated Angle ody Multi-Purpose Valves ronze or 36L Stainless Steel odies 3/8" to 2 /2" NPT 2/2 SRIS 82 The 82 Series consists of 2-way direct acting valves available in normally
More informationPILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series
PILOT OPERTED PRESSURE CONTROLS FLNGED TPE VR5 Series Veljan Flanged type, Valves Series VR5V ( Relief ), (Unloader) and VR5S (Sequence ) are pilot controls. These range of valves are suitable for mountg
More informationG2 Industrial Grade Meters
G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine
More informationAdvantages. Options VHS06
Flow switches for insertion installation Threaded adapter with trimmable paddle Type VHS06 Type VK306 Technical data VHS06 VK306 Switching function Contact closes at increasing flow opens at decreasing
More information83 series Brass compression fittings Ø 1/ nominal pipe size, NPT thread
83 series rass compression fittings Ø /8..., NPT thread For use in areas of vibration Pre-assembled units No special assembly tools or heat required an be remade without damage to tube Suitable for use
More informationCatalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility
atalog Product atalog Setting a new standard for: Quality Reliability Value Global ompatibility Table of ontents 3- Valves 3 irect Acting Solenoid Valves (M3V) 4-5 3-Way Solenoid Valves (M3V) 6-7 4-Way
More informationTable of Contents. Quick Coupling Products
Quick oupling Products Table of ontents Table Of ontents...1 Fluid Quick ouplings...3 oupling Selection uide...4 Non-Spill ouplings...5 FS Series...5 ouplers...6 Nipples...7 FS Series ust aps & Plugs...8
More informationQUANTUM. Quantum Low Power Control Monitor LOW POWER CONTROL MONITOR. " Design Features
LOW POWER ONTROL MONITOR Quantum Low Power ontrol Monitor " esign Features Single oil " General Purpose " Nonincendive " Explosionproof " Intrinsically Safe ual oil " General Purpose " Nonincendive " Explosionproof
More informationKIP Solenoid Selection
KIP Solenoid Selection Solenoid Selection 1/2" NPT onduit dapter Nut Housing Stop Orifice (Normally Open) Spring Loaded Top Seal oil Plunger Spring, Plunger, tn ottom Seal Guide ssembly Shading ing ( Only)
More information3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators
lectric, Hydraulic, and Pneumatic ctuators TL 1. Select Valve ody including P ode (Valve Size, v Rating, Port ode) or select Valve ssemly correct (refer to Tale 3 and Tale 3 also) less ctuator ode (XXX)
More informationPoppet Series Compressed Air & Vacuum
Poppet Series ompressed ir & Vacuum www.asco.com Table of ontents Poppet eatures and enefits ow to Order N Series - ompressed ir Valve Solenoid ir Pilot ctuated /8" to /8" Technical ata /8" to /8" imensions
More informationSeries 1, 2 & 6 Options selector. Port 4 = 1/8" NPT 5 = 1/4" NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF
KIP Isolation Valves Ideal for control of corrosive and aggressive media Elastomer diaphragm provides protection from aggressive, corrosive, and gritty media Isolation valves can be equipped with a low
More informationCALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range
iverter and isolation valves for panel radiators 00, 0, 02, 0 series RIT LI 006/2 N ISO 900 M 2654 ISO 900 No. 000 unction aleffi 0 series valves are installed on panel style radiators. They are connected
More informationPILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series
PILOT OPERTED PRESSURE CONTROLS FLNGED TPE VR5 Series Veljan Flanged type, Valves Series VR5V ( Relief ), VR5U (Unloader) and VR5S (Sequence ) are pilot controls. These range of valves are suitable for
More informationMIL Class M Series D*M D*MA connectors and crimp contacts
eatures/enefits *M (Removable crimp contacts technology) : QPL listed 24308 class M onnectors *M (Solder bucket) : QPL listed 24308 class M onnectors *M (90 P) : QPL listed 24308 class M onnec tors Non-Magnetic
More informationPaint/Solvent/Dump Valve and Flow-Through Valve
Instruction Sheet P/N 08573D Paint/Solvent/Dump Valve and Flow-Through Valve. Description See Figure. The paint/solvent/dump valve is a normally-closed valve that opens to trigger and/or dump coating material.
More informationWater Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.
Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS1 1.25 Control Valve Series Model: WS1.25 Operation and Instruction Manual for OEM Only. Please Note: This operation
More informationHow to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa
oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure
More informationHR-line. Heat recovery unit with counterflow heat exchanger. To be operated with cooling and / or after-heating. High Efficiency > 90%
10 R-line eat recovery unit with counterflow heat exchanger To be operated with cooling and / or after-heating igh fficiency > 90% quipped with fans oldbridge free Aluminum anodized frame construction
More informationFleck Fiberglass Section 9 Chloride Dealkalizers
Fleck Fiberglass Section 9 Fleck Fiberglass (*) Note: Steel tanks & Plastic Valve Nest (*PVN) systems are offered on custom quote basis Section 9 - Fleck Fiberglass Catalog 999701-NP Rev. F (05/17) Effective
More informationVic -300 Butterfly Valves
R IPS RON STL PIP ROOV VLVS 08.0 Vic -300 utterfly Valves PROUT SRIPTION ear Operator 3" with Position andle Vic -300 butterfly valves are designed for pressures ranging from vacuum to 300 PSI (065 kpa).
More informationPILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V
PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and work Internal Dra on the prciple of hydraulic balancg. These valves are used to limit
More informationFEATURES. ANSI Class 150 or 300. Complete line of accessories. MATERIALS OF CONSTRUCTION
PW Series igh Performance Wafer Style utterfly Valve The PW is a high performance wafer style butterfly valve that can be equipped with a manual handle or with pneumatic or electric actuators. full range
More information4 Winslow Depth Filters
4 Winslow epth ilters Winslow Lube Oil ilters... 4-3 Introduction... 4-4 Selecting a Lube Oil ilter.... 4-5 ull-low Type 1... 4-6 y-pass Type 1............................... 4-9 ull-low Type 2... 4-12
More informationMTX and WPX Turbine Flowmeters
Principle of Operation Liquid enters the precision metering insert containing the turbine rotor. The liquid pressure drives the turbine rotor rate of rotation proportional to the volumetric flow rate.
More informationFEATURES. ANSI Class 150 or 300. Complete line of accessories. MATERIALS OF CONSTRUCTION
PL Series igh Performance Lug Style utterfly Valve The PL is a high performance lug style butterfly valve that can be equipped with a manual handle or with pneumatic or electric actuators. full range of
More informationLOC-LINE the original modular coolant hose system
endless solutions, flexibility & performance COOLANT CONTROL LOC-LINE the original modular coolant hose system 8 1 9 8 6 13 4 The combinations and flexibility offered by Loc-Line shows that whatever your
More informationPILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V
PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and work Internal Dra on the prciple of hydraulic balancg. These valves are used to limit
More informationMK Series High Performance Butterfly Submittal/Technical Data
MK Series igh Performance utterfly Submittal/Technical ata ray MK Series igh Performance utterfly Valves NSI lass 150 and 300 ray ontrols ommercial ivision 13788 West Road, Suite 200 ouston, Texas 77041
More informationInstrument Ball Valves
www.swagelok.com Instrument all s 40 Series On-off, switching, and crossover flow paths Working pressures up to 3000 psig (206 bar) Temperatures from 50 to 150 (10 to 65 ) Low-temperature service option
More informationNO SHAFT SEAL, LESS PROBLEMS UP TO 200GPM AND 160 FEET MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS
NO SHAFT SEAL, LESS PROBLEMS UP TO 200GPM AND 160 FEET MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS MARCH PUMPS Why A ic Drive Pump A magnetic drive pump is sealless, preventing any leakage that is normally
More informationEmergency Shear Valves
Emergency Shear Valves 0060 Underpump Emergency Valve The Emco Wheaton 0060 Emergency Shear Valve incorporates a replaceable shear section and a heat sensitive fusible link assembly. The valve can be manually
More informationGeneral Specifications
Slides Rotaries Programmable Illuminated P Pushbuttons Supplement ccessories Indicators eneral Specifications lectrical apacity Resistive Load: 0 @ 5V, @ 50V, or @ 0V Inductive Load: 5 @ 5V (P.. @.0) Other
More informationWATTS/Taras. Water Treatment Valves and Accessories. Commercial. Residential
WATTS/Taras Water Treatment Valves and Accessories Residential Commercial Taras Valve Company, a division of Watts Industries, has been manufacturing quality by-pass valves and accessories for the Water
More informationPower Generation. Solenoid & Air Operated Valves
Power Generation Solenoid & ir perated Valves ompany Information... Quality Standards & eatures... Safety elated Way Valves... 4 Safety elated Way Valves... 6 Safety elated 4 Way Valves... 8 Safety elated
More informationMINIMATIC COMPACT - COMPETITIVE - FLOW CONTROL NORTHVALE KORTING LTD
MINIMTI OMPT - OMPETITIVE - FLOW ONTROL NORTHVLE KORTING LT MINIMTI ontrol Valves range of compact, lightweight, low cost control valves for use on liquid steam or gas applications. vailable in 2 way and
More informationOWNER S MANUAL FOR ALL GREENSAND SYSTEMS
OWNER S MANUAL FOR ALL GREENSAND SYSTEMS THIS MANUAL IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE AND PURPOSES AND TECHNICAL GUIDANCE. IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE
More information