Commercial Softeners
|
|
- Herbert Sanders
- 5 years ago
- Views:
Transcription
1 Commercial Softeners Product Index Page General System Specifications 35 Fleck Commercial Valve Configurations 36 Fleck /" Systems 37 Fleck /" Systems 38 Fleck 3150 " Systems 39 Fleck 900 " Systems 40 Fleck 900 " Duplex Systems 41 Fleck " Systems 4 Fleck " Duplex Systems 43 NXT Electronic Options for Fleck Commercial Systems 44 Clack WS /" Systems 45 Clack WS /" Twin Alternating Systems 45 Clack WSEE/QC " Systems 46 Clack WS " Twin Alternating Systems 46 Clack WSH " Heavy Systems 47 Clack WSH " Multi Tank Systems 48 Clack WS3 3" Heavy Systems 49 Clack WS3 3" Multi Tank Systems 50 Fleck 4650 and 9000 Hot Water Systems 51 Water. It s Our Life! Section
2 notes 34 Water. It s Our Life!
3 Commercial Equipment Sizing Commercial Equipment Nelsen Corporation Commercial/Industrial water treatment equipment is designed for a wide variety of applications. Potential uses include apartment complexes, hospitals, factories, nursing homes and many other applications where high flow rates and capacities are a requirement. One of the requisites for a successful and profitable sale is the proper matching of equipment to the intended use. Water softening equipment must be designed and sized according to the job it must perform. This indicates the need for a carefully selected combination of tank sizes, capacities and flow rates. The chart below lists the general specifications for units that we build. 35 GENERAL SPECIFICATIONS FOR MOST UNITS IN THIS SECTION (Call us for detailed specifications on specific units) GRAINS CAPACITY 10, ,000 10, , , , ,000 1,00,000 Grains Capacity (1) 10, ,000 10, , , , ,000 1,00,000 Grains Capacity () 96,000 10, ,000 40, , ,000 70, ,000 Cubic Ft. Material Pounds Mineral Gravel Bed, 1/4" x 1/8" 75# 100# 50# 100# 100# 150# 50# 300# Gravel Bed, 1/" x 1/4" # 150# 50# 350# 450# 600# Mineral Tank Size 16" x 65" 18" x 65" 1" x 6" 4" x 7" 30" x 7" 36" x 7" 4" x 7" 48" x 7" SVC Flow Rate, G.P.M.* Varies Varies Varies Varies Varies Varies Varies Varies Backwash Flow Commercial Brine Tank 4" x 41" 4" x 50" 4" x 50" 30" x 48" 39" x 48" 50" x 60" 50" x 60" 50" x 60" Floor Space Required 4" x 4" 4" x 47" 4" x 47" 30" x 56" 39" x 71" 50" x 88" 50" x 94" 50" x 100" (1) At 15 Pounds Per Cubic Foot = 30,000 Gr. C.F. () At 9 Pounds Per Cubic Foot = 4,000 Gr. C.F. *Please consult the following pages for sizing, flow rates, and pricing on all available models. Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
4 Commercial System Valve Configurations 36 System 4 - Single Valves Time Clock (1 Valve) The control regenerates on the days set in Regeneration Day Override, at the Regeneration Time set in Regeneration Time. Meter Delayed (1 Valve) The control regenerates on the day the available volume of treated water drops to less than the reserve volume. Regeneration starts at the Regeneration Time. Meter Immediate (1 Valve) The control regenerates immediately when the available volume of treated water drops to zero (0). System 5 (Fleck controls only) Meter Immediate (Interlock) ( 4 Valves) This is a to 4 unit system, each unit having a meter, and all in service. Only one unit is allowed in regeneration at a time. A unit regenerates immediately when the available volume of treated water drops to zero (0) and no other unit is in regeneration. System 6 - Meter Immediate Series ( 4 Valves) This is a to 4 unit system, all in service, with one meter for the entire system. When the entire system volume of treated water drops to zero (0), it requests the first unit to go into regeneration. Then, when the first unit is done regenerating, the second follows, and so on. System 7 Meter Alternating ( Valves) This is a unit system, with only one unit having a meter and only one unit in service. When the volume of treated water drops to zero (0) in the unit in service, it requests regeneration. This causes the unit in standby to move to service. Then the unit requesting regeneration moves to standby and begins regeneration. System 9 Meter Alternating ( 4 Valves) This is a or 4 unit system, each unit having a meter, one unit in standby and all other units in service. Only one unit is allowed in regeneration at a time. When the volume of treated water drops to zero (0) in the unit in service, it requests regeneration. This causes the unit in standby to move to service. Then the unit requesting regeneration moves to standby and begins regeneration. System 14 Meter Progressive ( 4 Valves) This is a 3 or 4 unit system, each unit having a meter, one unit in service and all other units in standby. As flow rates increase, units in standby go into service. As flow rates decrease units in service go back into standby until only one unit is in service. Only one unit is allowed in regeneration at a time. When the volume of treated water drops to zero (0) in the unit in service, it requests regeneration. This causes the unit in standby to move to service. Then the unit requesting regeneration moves to standby and begins regeneration. Note: 1) All Simplex Units to have hard water bypass pistons (White). ) All Duplex, Triplex and Quads to be 300NXT valves with No Hard Water bypass pistons (Black). Fax Nelsen OHIO , ARIZONA , TEXAS or FLORIDA
5 Part Number Fleck 9500 Twin Systems Fleck 9500/ /" Auto. Meter Systems Includes Fleck 9500/ / inch valve with 1700 time brining, commercial distributors, gravel bed, dual mineral tanks, commercial brine tank with air check and high-capacity resin. 95/17M-10-C441 10,000 Grain System $ 7, /17M-150-C ,000 $ 8, /17M-10-C450 10,000 $ 8, /17M-300-C ,000 $ 11,90.00 Fleck 9500 Control Valve Features Fully adjustable 5-cycle control delivers controlled up-flow backwash, down-flow brining, slow rinse, rapid rinse, timed brine refill and down-flow service Easily-adjustable, 5-cycle, down-flow-brining control Backwash capability handles up to 4" diameter tanks eliminating excessive, space wasting multiple tank installations Rugged, long-life construction features a lead-free brass* valve body Total flexibility in meter and timer setting Satisfies operational needs from 310 to 53,15 gallons Uses conditioned water for regeneration Salt and water savings by using 100% capacity of the tank in service before switching to the second tank Regenerates immediately when needed for continuous soft water Regenerates with soft water and keeps system clean for optimum operating efficiency and minimum maintenance FLECK 9500 valve with optional SXT Controller 37 Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight 95/17M x 65 4 x 41 96k 10k x 4 x /17M x 65 4 x 50 10k 150k x 4 x /17M-10 1 x 6 4 x k 10k x 4 x /17M x 7 30 x 48 40k 300k x 30 x Capacities are based on resin manufacturer s data All units set at minimum salt settings When sizing units, use minimum capacity All flow rates are in Gallons Per Minute All sizes and space required are in inches 1-1/" Meter Range Std. Range - 10,65 Gallons Ext Range - 53,15 Gallons Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
6 Fleck 850 Systems Part Number FLECK 850 Back View Fleck 850/ /" Commercial Systems Includes Fleck 850/ /" valve with 1700 time brining, commercial distributors, gravel bed, commercial brine tank with air check and high-capacity resin. 850/1700 AUTOMATIC TIME CLOCK SYSTEMS 85/17T-10-C441 10,000 Grain System $ 3, /17T-150-C ,000 $ 3, /17T-10-C450 10,000 $ 3, /17T-300-C ,000 $ 5, /17T-450-C ,000 $ 7, /1700 AUTOMATIC METER SYSTEMS 85/17M-10-C441 10,000 Grain System $ 4, /17M-150-C ,000 $ 4, /17M-10-C450 10,000 $ 5, /17M-300-C ,000 $ 6, /17M-450-C ,000 $ 8, Fleck 850 Features Offers best-in-class flow rates in a 1.5" commercial valve Multi-tank system capability Increased service and backwash flow Fully adjustable 5-cycle control delivers controlled up-flow backwash, down-flow brining and slow rinse, rapid rinse, timed brine refill and down-flow service Time-tested, hydraulically-balanced piston, seal and spacer design to pilot service flow and regeneration Solid lead-free brass* valve body for superior strength and durability 1.5" top mount control valve ideal for smaller size commercial/ industrial applications Backwash capacity handles up to 36" diameter tanks for softeners Ideal for most filter applications up to 30" diameter tanks Consistent brining regardless of salt levels with timed brine refills Choice of 7-or 1-day clock, manual or volume initiated timers Continuous service flow rate of 70 GPM with a backwash of 70 GPM Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight 85/ x 65 4 x 41 96k 10k x 4 x / x 65 4 x 50 10k 150k x 4 x / x 6 4 x k 10k x 4 x / x 7 30 x 48 40k 300k x 30 x / x 7 39 x k 450k x 39 x Capacities are based on resin manufacturer s data All units set at minimum salt settings When sizing units, use minimum capacity All flow rates are in Gallons per Minute All sizes and space required are in inches 1-1/" Meter Range Std. Range - 10,65 Gallons Ext Range - 53,15 Gallons Fax Nelsen OHIO , ARIZONA , TEXAS or FLORIDA
7 Part Number Fleck 3150 Two Inch Commercial Systems FLECK 3150 Back View Fleck 3150/1800 " Commercial Systems Includes Fleck 3150 " top mount valve with 1800 time brining, hub and lateral distributor, gravel bed, commercial brine tank with air check & 4" brine well and high-capacity resin. Please Note: The piping from the brine tank to the mineral tank is NOT provided with these systems. One-inch connections are provided at the 1800 brine valve and brine tank. Local plumbing codes and flow rates dictate the type of piping used between the brine tank and mineral tank. Also note, the maximum flow rate for a 350 safety valve is 10 gallons per minute. The recommended refill rate for a 1,00,000 grain system is 15 gallons per minute. A consideration should be made as to the type or number of air check(s)/safety(s) installed in the brine tank with these systems AUTOMATIC TIME CLOCK SYSTEMS 315/18T-10-C450 10,000 Grain System $ 5, /18T-300-C ,000 $ 7, /18T-450-C ,000 $ 9, /18T-600-C ,000 $ 11, /18T-900-C ,000 $ 15, AUTOMATIC METER SYSTEMS 315/18M-10-C450 10,000 Grain System $7, /18M-300-C ,000 $8, /18M-450-C ,000 $10, /18M-600-C ,000 $1, /18M-900-C ,000 $16, Fleck 3150 Features Fully adjustable, 5-cycle control is efficient and reliable, delivering controlled up-flow backwash, down-flow brining and down-flow service Versatile top or side mount is suitable for commercial or industrial applications Backwash capacity accommodates tanks up to 63" diameter Solid, lead-free brass* construction for superior strength and durability Protective NEMA 3R equivalent enclosure is rain tight, and UV stable Flexible 7 or 1 day time clock or meter initiated regeneration Ideal for most filter applications up to 4" Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight 315/ x 6 4 x k 10k x 4 x / x 7 30 x 48 40k 300k x 30 x / x 7 39 x k 450k x 39 x / x 7 50 x k 600k x 50 x / x 7 50 x 60 70k 900k x 50 x Capacities are based on resin manufacturer s data All units set at minimum salt settings When sizing units, use minimum capacity All flow rates are in Gallons per Minute All sizes and space required are in inches " Meter Range Std. Range - 1,50 Gallons Ext Range - 106,50 Gallons Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
8 40 Fleck 900 Simplex Systems Single-Piece Casting shown with treated water regeneration adapter Part Number Fleck 900/1700 " Commercial Systems Includes Fleck 900/1700 " valve with 1700 time brining, commercial distributors, gravel bed, and high-capacity resin. Commercial brine tank(s) includes a Clack 454 Hi-Flow Safety Valve, air check, overflow elbow, 5" brine well and cap. 900/1700 AUTOMATIC TIME CLOCK SYSTEMS 9/17T-10-C441 10,000 Grain System $ 3, /17T-150-C ,000 $ 4, /17T-10-C450 10,000 $ 4, /17T-300-C ,000 $ 5, /17T-450-C ,000 $ 8, /17T-600-C ,000 $ 10, /1700 AUTOMATIC METER SYSTEMS 9/17M-10-C441 10,000 Grain System $ 3, /17M-150-C ,000 $ 4, /17M-10-C450 10,000 $ 4, /17M-300-C ,000 $ 5, /17M-450-C ,000 $ 9, /17M-600-C ,000 $ 10, / NXT SIMPLEX TIME CLOCK SYSTEMS 9/17NXT-10-C441 10,000 Grain System $ 4, /17NXT-150-C ,000 $ 4, /17NXT-10-C450 10,000 $ 4, /17NXT-300-C ,000 $ 6,3.00 9/17NXT-450-C ,000 $ 8, /17NXT-600-C ,000 $ 10, Product Features Incorporates time-tested hydraulically balanced pistons to independently pilot service flow and regeneration Brings great performance and versatility to commercial/industrial applications For use with the single or multiple tank systems Softener Application Capabilities Up to 36 Tanks (5gpm/sq. ft.) Service Flow Rate 106 GPM (15 psi drop) Available with 7 or 1 day time clock or meter to control regeneration Lead-free brass valve body for superior strength and durability No hard water bypass piston Filter Application Capabilities Up to 4 Tanks (10gpm/sq. ft.) New Drain Size Fitting of 1 NPT Max Backwash Rate of 35 GPM (5 psi drop) Optional NXT controllers available Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight 9/ x 65 4 x 41 96k 10k x 4 x / x 65 4 x 50 10k 150k x 4 x / x 6 4 x k 10k x 4 x / x 7 30 x 48 40k 300k x 30 x / x 7 39 x k 450k x 39 x / x 7 50 x k 600k x 50 x Capacities are based on resin manufacturer s data All units set at minimum salt settings When sizing units, use minimum capacity All flow rates are in Gallons per Minute All sizes and space required are in inches " Meter Range Std. Range - 1,50 Gallons Ext Range - 106,50 Gallons Fax Nelsen OHIO , ARIZONA , TEXAS or FLORIDA
9 Part Number Fleck 900 Duplex Systems FLECK 300XNT CONTROLLER FLECK 300XNT CONTROLLER For Triplex and Quad units please call for additional pricing and specifications. 900/1700-NXT SYSTEM 5 DUPLEX Features include Fleck 900/ NXT Simplex System with an electronic meter for each valve and includes two commercial brine tanks with the Clack 454 commercial shutoff valve. 9/17NXT5-10-C441 10,000 Grain System $ 11, /17NXT5-150-C ,000 $ 1, /17NXT5-10-C450 10,000 $ 13, /17NXT5-300-C ,000 $ 16, /17NXT5-450-C ,000 $ 1, /17NXT5-600-C ,000 $ 4, /1700-NXT SYSTEM 6 DUPLEX Features include two Fleck 900/ NXT Simplex Systems with one " electronic meter for the system, also includes two commercial brine tanks with the Clack 454 commercial shutoff valve. 9/17NXT6-10-C441 10,000 Grain System $ 9, /17NXT6-150-C ,000 $ 10, /17NXT6-10-C450 10,000 $ 11, /17NXT6-300-C ,000 $ 14, /17NXT6-450-C ,000 $ 19, /17NXT6-600-C (3" meter included) $, /1700-NXT SYSTEM 7 DUPLEX Features include two Fleck 900/ NXT Simplex Systems with one " electronic meter for the system, also includes one commercial brine tank with the Clack 454 commercial shutoff valve. 9/17NXT7-10-C441 10,000 Grain System $ 9, /17NXT7-150-C ,000 $ 10, /17NXT7-10-C450 10,000 $ 11, /17NXT7-300-C ,000 $ 13, /17NXT7-450-C ,000 $ 18, /17NXT7-600-C ,000 $ 1, System 5 Units System 6 Units System 7 Units 9/17NT x 4 x /17NT x 4 x /17NT x 4 x /17NT x 30 x /17NT x 39 x /17NT x 50 x /17NT x 4 x /17NT x 4 x /17NT x 4 x /17NT x 30 x /17NT x 39 x /17NT x 50 x /17NT x 4 x /17NT x 4 x /17NT x 4 x /17NT x 30 x /17NT x 39 x /17NT x 50 x " Meter Range Std. Range - 1,50 Gallons Ext Range - 106,50 Gallons 3" Meter Range Std. Range - 63,750 Gallons Ext Range - 318,750 Gallons Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
10 Fleck 3900 Simplex Systems Part Number 4 FLECK 3900 VALVE BACK VIEW Fleck 3900/1800 3" Commercial Systems Includes Fleck 3900/1800 3" valve with 1800 time brining, hub and lateral distributor, gravel bed, and high capacity resin. Commercial brine tank includes a Clack 494 Hi-Flow Safety Valve, air check, overflow elbow, 5" brine well and cap. Please Note: The piping from the brine tank to the mineral tank is NOT provided with these systems. One-inch connections are provided at the 1800 brine valve and brine tank. Local plumbing codes and flow rates dictate the type of piping used between the brine tank and mineral tank. The recommended refill rate for a 1,00,000 grain system is 15 gallons per minute. A consideration should be made as to the type or number of air check(s)/safety(s) installed in the brine tank with these systems. 3900/1800 AUTOMATIC TIMER SYSTEMS 39/18T-300-C ,000 Grain System $ 11, /18T-450-C ,000 $ 13, /18T-600-C ,000 $ 14, /18T-900-C ,000 $ 18, /18T-100-C5060 1,00,000 $ 1, /1800 AUTOMATIC METER SYSTEMS 39/18M-300-C ,000 Grain System $ 13, /18M-450-C ,000 $ 15, /18M-600-C ,000 $ 17, /18M-900-C ,000 $ 1, /18M-100-C5060 1,00,000 $ 3, / NXT SIMPLEX TIME CLOCK SYSTEMS 39/18NXT-300-C ,000 Grain System $ 11, /18NXT-450-C ,000 $ 13, /18NXT-600-C ,000 $ 14, /18NXT-900-C ,000 $ 18, /18NXT-100-C5060 1,00,000 $ 1,56.00 FLECK 3900 Control Valve Product Features Fully adjustable 5-cycle control delivers controlled up-flow backwash, downflow brining, slow rinse, rapid rinse and down-flow service Designed for single tank or multi-tank systems, alternating or interlocking Continuous flow rate of 50 GPM Protective NEMA 3R enclosure is water resistant, rain tight, corrosion resistant and UV stable Operational no hard water bypass during regeneration Choice of 7 or 1 day clock or meter initiated regeneration No hard water bypass Optional NXT controllers available Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight 39/ x 7 30 x 48 40k 300k x 30 x / x 7 39 x k 450k x 39 x / x 7 50 x k 600k x 50 x / x 7 50 x 60 70k 900k x 50 x / x 7 50 x k 100k x 50 x Capacities are based on resin manufacturer s data All units set at minimum salt settings When sizing units, use minimum capacity All flow rates are in Gallons per Minute All sizes and space required are in inches 3" Meter Range Std. Range - 63,750 Gallons Ext Range - 318,750 Gallons Fax Nelsen OHIO , ARIZONA , TEXAS or FLORIDA
11 Part Number Fleck 3900 Duplex Systems FLECK 3900NXT CONTROL Valve 3900/1800-NXT SYSTEM 5 DUPLEX Features include two Fleck 3900/ NXT Simplex Systems with a 3" electronic meter for each valve and includes two commercial brine tanks with the Clack 494 commercial shutoff valve. 39/18NXT5-300-C ,000 Grain System $ 7, /18NXT5-450-C ,000 $ 30, /18NXT5-600-C ,000 $ 33, /18NXT5-900-C ,000 $ 41, /18NXT5-100-C5060 1,00,000 $ 46, /1800-NXT SYSTEM 6 DUPLEX Features include two Fleck 3900/ NXT Simplex Systems with one 3" electronic meter for the system, also includes two commercial brine tanks with the Clack 494 commercial shutoff valve. 39/18NXT6-300-C ,000 Grain System $ 5, /18NXT6-450-C ,000 $ 8, /18NXT6-600-C ,000 $ 3, /18NXT6-900-C ,000 $ 39, /18NXT6-100-C5060 1,00,000 $ 45, /1800-NXT SYSTEM 7 DUPLEX Features include two Fleck 3900/ NXT Simplex Systems with one 3" electronic meter for the system, also includes one commercial brine tank with the Clack 494 commercial shutoff valve. 39/18NXT7-300-C ,000 Grain System $ 4, /18NXT7-450-C ,000 $ 7, /18NXT7-600-C ,000 $ 30, /18NXT7-900-C ,000 $ 38, /18NXT7-100-C5060 1,00,000 $ 43, FLECK 3900NXT CONTROL Valve SYSTEM 5 UNITS System 6 Units System 7 Units 39/18NT x 30 x /18NT x 39 x /18NT x 50 x /18NT x 50 x /18NT x 50 x /18NT x 30 x /18NT x 39 x /18NT x 50 x /18NT x 50 x /18NT x 50 x /18NT x 30 x /18NT x 39 x /18NT x 50 x /18NT x 50 x /18NT x 50 x Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
12 Fleck 300 NXT Controller Specs, Electronic Meters Part Number FLECK 300XNT CONTROLLER Fleck 300NXT Electronic Systems The 300NXT Network Controller uses on-board communication capabilities to link multiple commercial valves (via off-the-shelf CAT3, CAT5, or better cables) for a variety of system types. The 300NXT is configured for use with Fleck 750, 850s, 900s, 3150, and 3900 Control Valves, and also supports stager valves using butterfly or notched cams. x16 character backlit LCD display Networks up to four valves Field-configurable for System Types 4, 5, 6, 7, and 9 Auxiliary inputs and outputs - Remote signal start input - Remote lockout input - Programmable relay output/chemical pump output Easy installation with plug-in wiring harnesses Front panel diagnostics button - Flow rate - Peak flow rate - Totalizer - Hours between last two regenerations - Hours since last regeneration - Adjustable volume remaining - Valve position - Software version Easy time of day adjustment - Simply push the up or down button on the lead (#1) controller; time of day is automatically copied to the remaining controllers Five configurable cycle steps Remote signal start can be used simultaneously with time clock, meter immediate, or meter delayed regeneration triggers - Allows monitoring of flow and volume information in RSS applications Three programming levels User mode Master programming Diagnostics mode 44 FL300--elec-pl FL300--elec FL300 CABLE Fleck Electronic Water Meters FL300--ELEC " Electronic Meter $ 1, FL300-3-ELEC 3" Electronic Meter $, Fleck Plastic 300NXT Electronic Water Meter FL300--ELEC-PL " Plastic Body Electronic Meter $1, Fleck 300 Electronic Meter Cables FL300CABLE-35 35" Electronic Meter Cable $ 4.80 FL300CABLE-96 96" (8 ft) Elec Meter Cable $ FL300CABLE " (5 ft) Elec Meter Cable $ Clack " Electronic Meter The Clack " Inline meter is suited for commercial/industrial application. Constructed of Stainless Steel, this meter features a service flow rate range of 1.5 to 150 GPM. A 15-foot cable is included. Connection is " female pipe or -1/" groove lock coupling. CL--EM " Electronic Meter $ FL300--elec Fax Nelsen OHIO , ARIZONA , TEXAS or FLORIDA
13 Part Number Clack WS1.5 Commercial Systems WS1.5ee Control cl-15-em Clack WS1.5EE 1-1/" Commercial Systems includes Clack WS1.5EE 1-1/" control valve with commercial distributors, gravel bed, and highcapacity resin. Commercial brine tank(s) include(s) a Clack 454 Hi-Flow Safety Valve, air check, overflow elbow, 5" brine well and cap. WS1.5EE AUTOMATIC TIME CLOCK SYSTEMS WS1.5EET-10-C441 10,000 $ 3, WS1.5EET-150-C ,000 $ 3,95.00 WS1.5EET-10-C450 10,000 $ 4,4.00 WS1.5EET-300-C ,000 $ 6,13.00 FOR WS1.5EE AUTOMATIC METER SYSTEMS ADD CL-15-EM WS1.5 Meter Assembly Male x Female NPT $ Clack WS1.5EE 1.5" Twin Alternating Systems includes two base Clack Systems from above, one 1-1/" Stainless Steel Electronic Meter, one Clack 1-1/" MAV (Motorized Alternating Valve)and one Commercial brine tank equipped as follows, Clack 454 Hi-Flow Safety Valve, air check, overflow elbow, 5" brine well and cap. WS1.5EE-TA-10-C441 10,000 $ 7, WS1.5EE-TA-150-C ,000 $ 8,58.00 WS1.5EE-TA-10-C450 10,000 $ 9,50.00 WS1.5EE-TA-300-C ,000 $ 1, Product Features 1.5" top mount control valve suited for mid-size commercial/industrial applications Lead free brass valve body Economical stainless steel optional meter assembly Service flow rate of 60 gpm, backwash 50 gpm Solid state microprocessor with easy access front panel settings Front panel display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (Totalizer) Methods to initiate regeneration; meter immediate, meter delayed, time clock delayed Optional double backwash feature offers optimum regeneration, cleaning ability and efficiency Fully adjustable cycle times with 6-cycle control delivers controlled backwash, down-flow brining/slow rinse, second backwash, fast rinse, refill and down-flow service Coin Cell Lithium battery back-up with a 8 hour carry over 1-volt output AC Adapter provides safe and easy installation Post treated water regenerant refill Reliable and proven DC drive WS1.5EE Twin Alternating 45 Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight WS1.5EE x 65 4 x 41 96k 10k x 4 x WS1.5EE x 65 4 x 41 10k 150k x 4 x WS1.5EE-10 1 x 6 4 x k 10k x 4 x WS1.5EE x 7 30 x 48 40k 300k x 30 x Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
14 Clack WSEE Commercial Systems Part Number 46 wsee CONTROL VALVE WSEE/QC Control cl--em Clack WSEE " Commercial Systems includes Clack WSEE " valve with commercial distributors, gravel bed, and high-capacity resin. Commercial brine tank(s) includes a Clack 454 Hi-Flow Safety Valve, air check, overflow elbow, 5" brine well and cap. 30" mineral tanks and above with a 6" flanged top opening use the WSEE/QC control valve. WSEE AUTOMATIC Time clock SYSTEMS WSEET-10-C441 10,000 Grain System $ 3, WSEET-150-C ,000 $ 4,35.00 WSEET-10-C450 10,000 $ 4,74.00 WSEET-300-C ,000 $ 5, WSQCT-450-C ,000 $ 8,39.00 WSQCT-600-C ,000 $ 10, WSQCT-900-C ,000 $ 14,14.00 WSQCT-100-C5060 1,00,000 $ 16,94.00 FOR WSEE AUTOMATIC METER SYSTEMS ADD CL--EM WS Meter Assembly Male x Female NPT $ Clack WSEE " Twin Alternating Systems includes Clack System from above, " Stainless Steel Electronic Meter, and Clack " MAV (Motorized Alternating Valve). Commercial brine tank(s) includes a Clack 454 Hi-Flow Safety Valve, air check, overflow elbow, 5" brine well and cap. WSEE-TA-10-C441 10,000 Grain System $ 8, WSEE-TA-150-C ,000 $ 9, WSEE-TA-10-C450 10,000 $ 10, WSEE-TA-300-C ,000 $ 1, WSQC-TA-450-C ,000 $ 17,70.00 WSQC-TA-600-C ,000 $ 0, WSQC-TA-900-C ,000 $ 8, WSQC-TA-100-C5060 1,00,000 $ 33, Product Features " Top mount control valve suited for commercial/industrial applications Lead free brass construction Service flows - EE service 115 gpm, backwash 80 gpm - QC service 15 gpm, backwash 85 gpm Solid state microprocessor with easy access front panel settings Front panel display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (Totalizer) Post treated water regenerant refill Methods to initiate regeneration; meter immediate, meter delayed, time clock delayed optional double backwash feature offers optimum regeneration, cleaning ability and efficiency Fully adjustable cycle times with 6-cycle control delivers controlled backwash, downflow brining/slow rinse, second backwash, fast rinse, refill and down-flow service Coin Cell Lithium battery back-up with an 8 hour carry over 1-volt AC Adapter, safe & easy installation Reliable and proven DC drive Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight WSEE x 65 4 x 41 96k 10k x 4 x WSEE x 65 4 x 50 10k 150k x 4 x WSEE-10 1 x 6 4 x k 10k x 4 x WSEE x 7 30 x 48 40k 300k x 30 x WSQC x 7 39 x k 450k x 39 x WSQC x 7 50 x k 600k x 50 x WSQC x 7 50 x 60 70k 900k x 50 x WSQC x 7 50 x k 100k x 50 x Fax Nelsen OHIO , ARIZONA , TEXAS or FLORIDA
15 Part Number Clack WSH Heavy Commercial Systems Clack WSH " Heavy Commercial Systems Includes Clack WSH " commercial valve with commercial distributors, gravel bed, and high-capacity resin. Commercial brine tank(s) includes a Clack 454 or 494 (30" tank & larger) Hi-Flow Safety Valve, air check, overflow elbow, 5" brine well and cap. WSH AUTOMATIC METER SYSTEMS WSH-150-C ,000 Grain System $ 7,99.00 WSH-10-C450 10,000 $ 7, WSH-300-C ,000 $ 8, WSH-450-C ,000 $ 10,9.00 WSH-600-C ,000 $ 1, WSH-900-C ,000 $ 16, WSH-100-C5060 1,00,000 $ 19, clack wsh control valve Product Features " top mount or side mount control valve suited for commercial and industrial applications Epoxy coated lead free brass valve body WSH BACKSIDE Built-in Internal Flow Meter standard with all valves Service flow rate 15 gpm (473 lpm) (8.4 m3/h), Backwash flow rate 15 gpm (473 lpm) (8.4 m3/h) Solid state microprocessor with easy access front removable POD Front panel display for Time of Day, Current Flow Rate, Totalizer and Volume/Days until Regeneration Four methods to initiate the down flow regeneration; meter delayed, meter immediate, time clock delayed, or pressure differential Fully programmable regeneration cycle sequences (maximum 9) Fully programmable regeneration cycle times Pre or Post treated water regenerant refill Days override feature; 1-8 days available 0-volt output AC adapter provides safe and easy installation Reliable and proven DC drive Patented one piece expanding seal spacer stack assembly Patented linearly reciprocating piston operation WSH SIDEMOUNTED 47 Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight WSH x 65 4 x 41 10k 150k x 4 x WSH-10 1 x 6 4 x k 10k x 4 x WSH x 7 30 x 48 40k 300k x 30 x WSH x 7 39 x k 450k x 39 x WSH x 7 50 x k 600k x 50 x WSH x 7 50 x 60 70k 900k x 50 x WSH x 7 50 x k 100k x 50 x Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
16 Clack WSH Multi Tank Systems Part Number 48 CLACK MAV VALVE clack wsh control valve Twin Alternating System Photo shown for illustration purposes only, not shown with isolating ball valves. Clack WSH " Multi Tank Systems TWIN ALTERNATING SYSTEMS (System 7) Includes Two Base Clack Systems from the previous page and one Clack " MAV (Motorized Alternating Valve). A single commercial brine tank included. WSH-TA-150-C ,000 Grain System $ 14, WSH-TA-10-C450 10,000 $ 15, WSH-TA-300-C ,000 $ 17, WSH-TA-450-C ,000 $ 1, WSH-TA-600-C ,000 $ 5, WSH-TA-900-C ,000 $ 3, WSH-TA-100-C5060 1,00,000 $ 38,35.00 WSH TWIN ALTERNATING OR PROGRESSIVE FLOW SYSTEMS (System 6, 9, or 14) Add an additional MAV Valve to the System 7 price above. CL-MAV-0 WS " Motorized Alternator Valve Rev $ WSH TRIPLEX ALTERNATING OR PROGRESSIVE FLOW (System 6, 9, or 14) Includes Three Base Clack System from the previous page and 3 Clack " MAV (Motorized Alternating Valve). One commercial brine tank included in the prices below. Add any additional brine tanks needed for your specific system type. WSH-S9/S TRI-C ,000 Grain System $,5.00 WSH-S9/S14-10-TRI-C450 10,000 $ 3, WSH-S9/S TRI-C ,000 $ 6, WSH-S9/S TRI-C ,000 $ 3, WSH-S9/S TRI-C ,000 $ 37, WSH-S9/S TRI-C ,000 $ 49, WSH-S9/S TRI-C5060 1,00,000 $ 57, WSH QUAD ALTERNATING OR PROGRESSIVE FLOW (System 6, 9, or 14) Includes Four Base Clack Systems from the previous page and 4 Clack " MAV (Motorized Alternating Valve). One commercial brine tank included in the prices below. Add any additional brine tanks needed for your specific system type. WSH-S9/S QUAD-C ,000 Grain System $ 9,79.00 WSH-S9/S14-10-QUAD-C450 10,000 $ 31,16.00 WSH-S9/S QUAD-C ,000 $ 35, WSH-S9/S QUAD-C ,000 $ 43, WSH-S9/S QUAD-C ,000 $ 49,91.00 WSH-S9/S QUAD-C ,000 $ 64, WSH-S9/S QUAD-C5060 1,00,000 $ 75, WSH-TA x 4 x WSH-TA x 4 x WSH-TA x 30 x WSH-TA x 39 x WSH-TA x 50 x WSH-TA x 50 x WSH-TA x 50 x WSH-TRI x 4 x WSH-TRI x 4 x WSH-TRI x 30 x WSH-TRI x 39 x WSH-TRI x 50 x WSH-TRI x 50 x WSH-TRI x 50 x WSH-QUAD x 4 x WSH-QUAD x 4 x WSH-QUAD x 30 x WSH-QUAD x 39 x WSH-QUAD x 50 x WSH-QUAD x 50 x WSH-QUAD x 50 x Fax Nelsen OHIO , ARIZONA , TEXAS or FLORIDA
17 Part Number Clack WS3 Heavy Commercial Systems Clack WS3 3" Heavy Commercial Systems Includes Clack WS3 3" commercial valve with commercial distributors, gravel bed, and high-capacity resin. Commercial brine tank(s) includes a Clack 494 Hi-Flow Safety Valve, air check, overflow elbow, 5" brine well and cap. WS3 AUTOMATIC METER SYSTEMS WS3M-300-C ,000 Grain System $ 11, WS3M-450-C ,000 $ 15,64.00 WS3M-600-C ,000 $ 18, WS3M-900-C ,000 $ 3,79.00 WS3M-100-C5061 1,00,000 $ 6, clack ws3 control valve Product Features 3 top mount or side mount control valve suited for commercial and industrial applications Lead free brass valve body Economical stainless steel optional meter assembly Service flow rate 50 gpm (946 lpm) (56.8 m3/h), Backwash flow rate 0 gpm (833 lpm) (50.0 m3/h) Solid state microprocessor with easy access front removable POD Front panel display for Time of Day, Current Flow Rate, Totalizer and Volume/Days until Regeneration Methods to initiate the down flow regeneration; meter delayed, meter immediate, time clock delayed Fully programmable regeneration cycle sequences (maximum 9) Fully programmable regeneration cycle times Pre or Post treated water regenerant refill Days override feature; 1-8 days available Capacitor back-up with up to 4 hour carry over 0-volt output AC adapter provides safe and easy installation Reliable and proven DC drive WS3 BACKSIDE Model Tank Size Capacity Resin Support Bed Flow Rates BKW Salt Req d Space Req d Shipping Number Resin Brine Min Max Cu Ft 1 / x 1 /4 1 /4 x 1 /8 Min Max 9# 15# L x W x H Weight WS x 7 30 x 48 40k 300k x 30 x WS x 7 39 x k 450k x 39 x WS x 7 50 x k 600k x 50 x WS x 7 50 x 60 70k 900k x 50 x WS x 7 50 x k 100k x 50 x Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
18 Clack WS3 Multi Tank Systems Part Number 50 CLACK 3 MAV VALVE CL-30-EM Clack WS3 3" Multi Tank Systems WS3 TWIN ALTERNATING OR PROGRESSIVE FLOW SYSTEMS (System 6, 9, or 14) Includes Two Base Clack Systems from the previous page, two Clack 3" MAV (Motorized Alternating Valve) and two 3" meter assemblies. A single commercial brine tank included. WS3-S9/S C ,000 Grain System $ 5, WS3-S9/S C ,000 $ 3, WS3-S9/S C ,000 $ 40, WS3-S9/S C ,000 $ 47, WS3-S9/S C5060 1,00,000 $ 53, WS3 TRIPLEX ALTERNATING OR PROGRESSIVE FLOW (System 6, 9, or 14) Includes Three Base Clack Systems from the previous page, three Clack 3" MAV (Motorized Alternating Valve) and three 3" meter assemblies. One commercial brine tank included in the prices below. Add any additional brine tanks needed for your specific system type. WS3-S9/S TRI-C ,000 Grain System $ 38, WS3-S9/S TRI-C ,000 $ 49,08.00 WS3-S9/S TRI-C ,000 $ 59, WS3-S9/S TRI-C ,000 $ 71, WS3-S9/S TRI-C5060 1,00,000 $ 80,57.00 WS3 QUAD ALTERNATING OR PROGRESSIVE FLOW (System 6, 9, or 14) Includes Four Base Clack Systems from the previous page, four Clack 3" MAV (Motorized Alternating Valve) and four 3" meter assemblies. One commercial brine tank included in the prices below. Add any additional brine tanks needed for your specific system type. WS3-S9/S QUAD-C ,000 Grain System $ 51,36.00 WS3-S9/S QUAD-C ,000 $ 64, WS3-S9/S QUAD-C ,000 $ 78, WS3-S9/S QUAD-C ,000 $ 94, WS3-S9/S QUAD-C5060 1,00,000 $ 106, clack ws3 control valve WS3-TA x 30 x WS3-TA x 39 x WS3-TA x 50 x WS3-TA x 50 x WS3-TA x 50 x WS3-TRI x 30 x WS3-TRI x 39 x WS3-TRI x 50 x WS3-TRI x 50 x WS3-TRI x 50 x WS3-QUAD x 30 x WS3-QUAD x 39 x WS3-QUAD x 50 x WS3-QUAD x 50 x WS3-QUAD x 50 x Fax Nelsen OHIO , ARIZONA , TEXAS or FLORIDA
19 Part Number Nelsen Hot Water Systems Fleck 46/16T Automatic Hot Water Timer Systems includes Fleck 4650 L -back timer valve with 1600 time brining, special hot water modifications, with charcoal designer cover and vinylester mineral tank. An 11" x 38" brine tank with hot water safety is included with the 15,000 grain system. A charcoal 18" x 33" brine tank with hot water safety is included with the 48,000 grain systems. 46/16TB-15-C300-HW 15,000 Grain System $ 1, /16TB-48-C300-HW 48,000 $ 1, FLECK 4650 Hot water CONTROL VALVE Fleck 90/16M Automatic Hot Water Meter Systems Includes Fleck 9000 meter valve with 1600 time brining, 3/4" brass yoke, and vinylester mineral tanks. An 11" x 38" brine tank with hot water safety is included with the 15,000 grain system. A charcoal 18" x 33" brine tank with hot water safety is included with the 48,000 grain systems. 90/16M-15-C300-HW 15,000 Grain System $ 3, /16M-48-C300-HW 48,000 $ 3, FLECK 9000 HOT water CONTROL VALVE Call Nelsen Toll-Free OHIO , ARIZONA , TEXAS or FLORIDA
20 notes 5 Water. It s Our Life!
TNT SERIES WATER CONDITIONERS
TNT SERIES WATER CONDITIONERS For Commercial & Industrial Applications Apartment Buildings Boiler Water Treatment Car Washes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home
More informationControl Valves, Fittings and Accessories
Control Valves, Fittings and Accessories NEW WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SP 70 gpm WS2EE WS2SP 115 gpm WS2EE/QC* WS2SP/QC* 125 gpm WS1.25* WS1.25CS*
More informationControl Valves, Fittings and Accessories
Control Valves, Fittings and Accessories NOW WITH BATTERY PACK OPTION WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SD/SP 70 gpm WS2EE WS2SD/SP 115 gpm WS2EE/QC* WS2SP/QC*
More informationCOMMERCIAL / INDUSTRIAL WATER SOFTENERS
COMMERCIL / INDUSTRIL WTER SOFTENERS When performance & value matters. CONTROL VLVES SPECIFICTIONS EWS1 EWS1.5 EWS2QC Service @ 15 psi drop ackwash @ 25 psi drop 27 gpm (includes meter & bypass) 27 gpm
More informationControl Valves - Fleck, Autotrol, Clack, AquaMatic & Others
Control Valves - Fleck, Autotrol, Clack, AquaMatic & Others Product Index Page Fleck 2510 & 1500 Control Valves... 9-3 Fleck 4650 Hot Water Control Valve... 9-3 Fleck 5600, 6700 & ProFlo Control Valves...
More informationWater Specialist EE Control Valve Programming and Cover Drawing Manual
Water Specialist EE Control Valve Programming and Cover Drawing Manual Page 2 EE Man u al EE Man u al Page 3 Table of Contents EE Front Cover and Drive Assembly... 4 Regeneration and Error Screens, Button
More informationCAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER
CAT231.1 STANDARD FEATURES TASK MASTER III - 1 ½ / 2 - FIVE CYCLE 316 STAINLESS STEEL VALVE - SIDE MOUNT SUPER FLOW KIT S ON 2, 3 & 4 SYSTEMS (SERVICE FLOW BYPASS DIAPHRAGM VALVES) ERCt ELECTRONIC TIMER
More informationFleck Epoxy Lined Section 2 Steel Softeners
Epoxy Lined Section 2 Epoxy Lined *Shown with factory SKID & Plumbing Section 02 Epoxy Lined Catalog 999701-NP Rev. F (05/17) Effective 05/01/17 Section 2 Table of Contents Epoxy Lined Steel Softener Specifications
More informationCAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø
CAT231.1 STANDARD TASK MASTER III - 1 ½ VALVE 316 SS - SIDE MOUNT SERVICE FLOW BYPASS DIAPHRAGM VALVES. ERCt ELECTRONIC TIMER 100 PSI EPOXY LINED AND COATED CARBON STEEL MINERAL TANKS ACCUMATIC BRINE SYSTEM.
More informationFleck Top Mount Section 1 Fiberglass Softeners
Fleck Top Mount Section 1 Fleck Top Mount *Shown with factory SKID & Interconnecting Plumbing *Shown with factory SKID & Interconnecting Plumbing Section 01 Fleck Top Mount Catalog 999701-NP Rev. F (05/17)
More informationDETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS
5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS 1.0 SCOPE 1.1
More informationControl Valves - Fleck, Autotrol, Clack, Aquamatic & Others
- Fleck, Autotrol, Clack, Aquamatic & Others Product Index Page Fleck 2510 183 Fleck 4650 Hot Water Control Valve 183 Fleck 5600, 6700 & ProFlo 184 Fleck 5800, 5800 XTR2 185 Fleck Valve Covers, 185 By-Pass
More informationWater Specialist EI Control Valve Programming and Cover Drawing Manual
Water Specialist EI Control Valve Programming and Cover Drawing Manual Page 2 EI Man u al EI Man u al Page 3 Table of Contents EI Front Cover and Drive Assembly... 4 Regeneration and Error Screens... 5
More informationFLECK 2750 DOWNFLOW SERVICE MANUAL. waterpurification.pentair.com
FLECK 2750 DOWNFLOW SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING
More informationFLECK 2750 DOWNFLOW SERVICE MANUAL.
FLECK 2750 DOWNFLOW SERVICE MANUAL www.pentairaqua.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationClean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS
Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS Application of Commercial Water Softening Equipment Water hardness is responsible for many maintenance
More informationInstallation and Operations Manual
Excalibur Water Systems 3.0 High Capacity Superflow Series QUADPLEX Water Softener Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com Water
More informationDETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS
2227 South Street P.O. Box 044170 Racine, Wisconsin 53404-7003 Phone: 262-681-1300 Fax: 262-681-1318 www.marlo-inc.com DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS 1.0 SCOPE 1.1 Provide
More informationWater Specialist CI Control Valve Programming and Cover Drawing Manual
Water Specialist CI Control Valve Programming and Cover Drawing Manual Page 2 CI Man u al CI Man u al Page 3 Table of Contents CI Front Cover and Drive Assembly...4 OEM General Instructions...5 OEM Cycle
More informationFLECK 2850S SERVICE MANUAL. waterpurification.pentair.com
FLECK 2850S SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationSECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing
SECTION 1 *Shown with factory SKID & Interconnecting Plumbing Fleck Fiberglass Softeners Section 01 Fleck Fiberglass softeners Catalog 999502 Effective 01/01/13 Section 01 Fleck Fiberglass softeners Catalog
More informationFLECK 2900S SERVICE MANUAL. waterpurification.pentair.com
FLECK 2900S SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET 2 INSTALLATION 3 START-UP INSTRUCTIONS 3 3200 TIMER SETTING PROCEDURE 4 3210 & 3220 TIMER SETTING PROCEDURE
More informationPre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT)
Operation Manual Pre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT) 1020 Industrial Drive, Orlinda, TN 37141 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1
More informationPRESSURE GAGES AND TEST TAPS
CAT 500.1 FRF series filters. Polyglass 100 psi vessels with top mount Task Master II 1 ½ valve and single point PVC internals. FMF series filters. Carbon steel epoxy lined and coated vessels with side
More informationBLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09
TM BLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09 RESIDENTIAL SOFTENER EQUIPMENT TABLE OF CONTENTS PROFESSIONAL SERIES - FLECK 5600 VALVE PREMIUM GRADE RESIN - SPECIFICATIONS
More informationOwner s Manual HELLENBRAND, INC.
Owner s Manual Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin 53597-2509 Phone: 608-849-3050 Fax 608-849-7398 Web: www.hellenbrand.com Email: info@hellenbrand.com 800160
More informationFLECK 2850 CONTROL VALVE
FLECK 2850 CONTROL VALVE SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER
More informationFleck Fiberglass Section 9 Chloride Dealkalizers
Fleck Fiberglass Section 9 Fleck Fiberglass (*) Note: Steel tanks & Plastic Valve Nest (*PVN) systems are offered on custom quote basis Section 9 - Fleck Fiberglass Catalog 999701-NP Rev. F (05/17) Effective
More informationAQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS
AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS BUILDING SOLUTIONS AND PARTNERSHIPS AQ Matic is a leader in high technology flow control products and provides innovative solutions for commercial and
More informationWater Specialist PR Control Valve Programming and Cover Drawing Manual
Water Specialist PR Control Valve Programming and Cover Drawing Manual Page 2 PR Man u al PR Manual Page 3 Table of Contents PR Front Cover and Drive Assembly...4 OEM General Programming Instructions...5
More informationDETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS
5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS 1.0 SCOPE 1.1 Provide
More informationModel Downlow & Uplow
Model 2750 - Downlow & Uplow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Speciication Sheet... 3 General Commercial Pre-Installation Check
More information3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.
3200ET TIMER Service Manual IMPORTANT: Fill in pertinent information on page 2 for future reference. Installation And Start-Up Procedures Timer Programming Water Hardness System Capacity Regeneration Time
More informationFleck 2510 & 2510 Econominder
Fleck 2510 & 2510 Econominder Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION...2 START-UP INSTRUCTIONS...2 3200 TIMER SETTING PROCEDURE...3 3210 TIMER SETTING PROCEDURE...4 3200,
More informationINDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES
INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES 150,000 TO 1,100,000 GRAINS CAPACITY (Single, Twin, Triple or Quadruple Demand Systems Available) 1 P age Industrial Performance and Proven Reliability
More informationWater Specialist WS2H and WS3 Control Valve Manual
Water Specialist WS2H and WS3 Control Valve Manual HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC., MAY DAMAGE PRODUCTS THAT CONTAIN O-RINGS OR PLASTIC COMPONENTS. EXPOSURE TO SUCH HYDROCARBONS
More informationINDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES
INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES 150,000 TO 900,000 GRAIN CAPACITY (Single, Twin Alternating, Triple or Quadruple Demand Systems) 1 P age Industrial Performance and Proven Reliability
More informationModel 5600SXT Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
Model 5600SXT Upflow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 Installation Instructions... 4 Start-Up Instructions...
More informationModel 7000XTR. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
Model 7000XTR Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet 3 Water Softener Control Valve 4 Valve Installation and Start-Up
More informationFleck 5600SXT Upflow. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 5600SXT Upflow Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION...2 START-UP INSTRUCTIONS...2 TIMER FEATURES...3 TIMER OPERATION...4 MASTER PROGRAMMING MODE CHART...5 MASTER
More informationWater Specialist igen Control Valve Programming and Cover Drawing Manual
Water Specialist igen Control Valve Programming and Cover Drawing Manual Page 2 igen Man u al igen Man u al Page 3 Table of Contents igen Front Cover and Drive Assembly...4 WS1 igen Drive Cap Assembly,
More informationWater Specialist CK and EQ Control Valve Programming and Cover Drawing Manual
Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual Page 2 CK and EQ Manual CK and EQ Manual Page 3 Table of Contents CK Front Cover and Drive Assembly...4 OEM General Programming
More informationAQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES
AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL TABLE OF CONTENTS General Residential Installation 3 AQT-56SE Keypad 4 Control Operation 5 Master Programming - Setting the Time of Day 6 - Setting the Regeneration
More informationTECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL
TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES TIMER CHARACTERISTICS 742 TIME CLOCK Electronic time clock (chronometric)
More informationModel 5600SXT Downflow
Model 5600SXT Downflow Service Manual Distributed By: IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference 2325 Cousteau Ct. Vista, CA 92081 (760) 727-3711 (760) 727-4427 www.appliedmembranes.com
More informationAQT-275 SERIES SERVICE MANUAL CONTROL VALVES
AQT-275 SERIES CONTROL VALVES SERVICE MANUAL Table of Contents General Residential Installation 3 Valve Start-up Procedures 4 Regeneration Cycle Program Setting Procedures 5 Water Conditional Diagrams
More informationFLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL
FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 INSTALLATION... 3 START-UP INSTRUCTIONS... 4 CONTROL FEATURES... 4 CONTROL OPERATION...
More informationAQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES
AQT-56 POWERFLO SERIES SERVICE MANUAL Table of Contents Products Checking List 3 General Residential Installation Check List 4 AQT-56ST Softener Timer Control Valve Start-up Procedures 5 AQT-56FT Filter
More informationModel 2750 Downflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
Model 2750 Downflow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 Installation Instructions... 4 Start-Up Instructions...
More informationINSTALLATION, OPERATING AND SERVICE MANUAL
INSTALLATION, OPERATING AND SERVICE MANUAL ECONO-mist WATER SOFTENER Demand Regeneration 7-LMC56-75B 7-LM56-75B 7-LM56-100B 7-LM56-150B 7-LM56-200B Congratulations on purchasing your new Lancaster Water
More informationWater Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS
Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the
More informationDCS7 Water Softener - Product Manual
pg. 0 Set Up Instructions for DCS7 Water Softener Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. (Figure 1) Remove the resin tank(s) and valve(s) from the packaging.
More informationAquaMatic Control Valves, Stagers and Controllers
Pentair Water is a leader in high technology flow control products and provides innovative solutions for commercial and industrial applications. AquaMatic valves, stagers and controllers are key components
More informationFLECK 5600SXT DOWNFLOW
FLECK 5600SXT DOWNFLOW SERVICE MANUAL www.pentairaqua.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS/FLUSHING & CONDITIONING.4 CONTROL FEATURES...4 TIMER OPERATION...5
More informationBNT 85 /185 Valve Operation Manual
BNT 85 /185 Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant
More informationFLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL
FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL 2013 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS JOB SPECIFICATION SHEET... 2 INSTALLATION... 3 START-UP INSTRUCTIONS...
More information6700XTR Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
6700XTR Upflow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification
More informationIWT 565 Series Valve Operation Manual
IWT 565 Series Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant
More informationAquaMatic Series. A100 and A200 Stager Controls
AquaMatic Series A100 and A200 Stager Controls 2 Table of Contents Introduction To AquaMatic Series A100 and A200 Stager Controls3 Specifications 4 Applications 5 Features 6 Cycle Time Programming 7 Setting
More informationP/N: (Rev. G 1/19/10)
P/N: 7285512 (Rev. G 1/19/10) If you have questions when installing, programming, operating or maintaining this system CALL TOLL FREE in Canada call 1---800---627---3497 1---800---752---3273 1 SHIPMENT
More informationWater Specialist 1 Control Valve Series Model: WS1EI 1.25 Control Valve Series Model: WS1.25EI
Water Specialist Control Valve Series Model: WSEI.25 Control Valve Series Model: WS.25EI Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More informationOwners Manual Installation Instructions. For Models PTCF PTCF PTCF
Owners Manual Installation Instructions For Models PTCF-5600-09 PTCF-5600-10 PTCF-5600-13 Table of Contents Page 2 Subject Page PURE TECH 2000 Diagram 4 Job Specification Sheet 5 System Overview 6 Pre
More informationModel 2750 Downflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
Model 2750 Downflow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 Installation Instructions... 4 Start-Up Instructions...
More information3200NT Timer Service Manual
Service Manual Valve Serial Number Valve Position 1-LEAd 2-LAg 3-LAg 4-LAg IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet.....................................................................
More informationPre-Treatment Control Valve (Fleck 3150) & Timer (Fleck SXT)
Operation Manual Pre-Treatment Control Valve (Fleck 3150) & Timer (Fleck SXT) 1020 Industrial Drive, Orlinda, TN 37141 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL
More informationSpecifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation
Specifications GE Osmonics Autotrol 255 Series Valve Specifications Series Controllers Flow Rates (Valve Only) Service @ 15 psi (1.03 bar) drop 15.5 gpm (3.52 m 3 /h) Backwash @ 25 psi (1.72 bar) drop
More informationWater Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI
Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the
More informationFLECK 2510 SERVICE MANUAL. waterpurification.pentair.com
FLECK 2510 SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...2 INSTALLATION...3 START-UP INSTRUCTIONS...3 3200 TIMER SETTING PROCEDURE...4 3210 TIMER SETTING PROCEDURE...4
More informationMagnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work
Magnum Cv Valve Specifications Magnum IT and Standard Configurations imagination at work Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop....................... 76 (17.3 m 3 /hr) Backwash
More informationFLECK MODEL PROFLOSXT DOWNFLOW
FLECK MODEL PROFLOSXT DOWNFLOW SERVICE MANUAL www.pentairaqua.com TABLE OF CONTENTS JOB SPECIFICATION SHEET...3 INSTALLATION INSTRUCTIONS...4 START-UP INSTRUCTIONS...5 TIMER FEATURES...5 TIMER OPERATION...6
More information5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.
Brine Well Distributor Tube and basket Safety-Cut Off (Optional) $8.00 extra Air Check Assembly Over-Flow (Optional) $1.00 extra 5600 Control Valve Gravel (Optional) Bypass Piping Boss Inlet & Outlet Brine
More informationProFloSE. Downflow Brining Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.
ProFloSE Downflow Brining Service Manual IMPORTANT: Fill in pertinent information on page 2 for future reference. Job Specification Sheet Job Number Model Number Water Test Capacity Of Unit Max. Per Regeneration
More informationService Manual SXT Upflow Control Valve for Water Conditioning and Treatment Purposes
Service Manual 6200 SXT Upflow Control Valve for Water Conditioning and Treatment Purposes Table of Contents Job Specificaton Sheet and Valve Specifications...X Installation Instrucitons 6200SXT Upflow...X
More informationCOMMERCIAL CONTROL VALVES. Magnum Control Valve
COMMERCIAL CONTROL VALVES Magnum Control Valve COMMERCIAL CONTROL VALVES Magnum Control Valve Controller Options The Pentair Water Magnum Control Valve is one of the most versatile valves on the market.
More informationSuperior Water And Air
Superior Water And Air 80-974-9090 800-974-7638 OWNERS MANUAL Model 32-CL990 & 48-CL990 General Information Congratulations on having purchased a quality and well built Superior Water Softener. On a normal
More informationH-125 HE SERIES. Owner s Manual HIGH EFFICIENCY SYSTEM. Manufactured by: HELLENBRAND, INC. Web:
H-125 HE SERIES HIGH EFFICIENCY SYSTEM Owner s Manual p/n 800679 Rev. C Updated 10/02/18 2016-2018 Manufactured by: HELLENBRAND, INC. Web: www.hellenbrand.com Email: info@hellenbrand.com This owner s manual
More informationGeneral Operation. To set Time of Day. To set Time of Regeneration / Backwash
1 General Operation When the system is operating one of two displays will be shown: time of day or days until the next regeneration. Pressing UP or DOWN will toggle between the two choices. To set Time
More informationOWNER S MANUAL FOR ALL GREENSAND SYSTEMS
OWNER S MANUAL FOR ALL GREENSAND SYSTEMS THIS MANUAL IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE AND PURPOSES AND TECHNICAL GUIDANCE. IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE
More informationMGTE Series 1 1/2 Metered & Time Clock
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MGTE Series 1 1/2 Metered & Time Clock COMMERCIAL WATER CONDITIONERS COMPLETE FOR FUTURE REFERENCE: MODEL NO: SERIAL NO: DATE INSTALLED: DEALER: Marlo Incorporated
More informationModel ProFloSXT Downflow
Model ProFloSXT Downflow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents IMPORTANT PLEASE READ: The information, specifi cations and illustrations
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS Water Softeners WS-40 WS-80 WS-55 WS-500 WS-C206 WS-C208 WS-P213 A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43276 (November 2013) F-43276 (November
More informationWater Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25
Water Specialist 1 Control Valve Series Model: WS1 1.25 Control Valve Series Model: WS1.25 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More informationWater Specialist WS2H and WS3 Control Valve Drawings and Service Manual
Water Specialist WSH and WS Control Valve Drawings and Service Manual HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC., MAY DAMAGE PRODUCTS THAT CONTAIN O-RINGS OR PLASTIC COMPONENTS. EXPOSURE TO
More informationSOLICITATION C INSTALLATION AND MAINTENANCE OF POTABLE WATER FILTRATION SYSTEMS THROUGHOUT THE STATE OF FLORIDA QUESTIONS AND ANSWER
SOLICITATION 2015013C INSTALLATION AND MAINTENANCE OF POTABLE WATER FILTRATION SYSTEMS THROUGHOUT THE STATE OF FLORIDA QUESTIONS AND ANSWER The following questions have been submitted: 1. Could you tell
More information2inch Valve S D S D
2inch Valve 30184-132S 30185-132D 30185-192S 30185-192D SHIPMENT INSPECTION Thoroughly check the commercial system for possible shipping damage and/or parts loss. Also inspect and note any damage to shipping
More informationAquaMatic Products. Valves, Stagers and Controllers OVERVIEW. GE Water & Process Technologies
AquaMatic Products Valves, Stagers and Controllers GE Water & Process Technologies OVERVIEW GE GE is a diversified manufacturer of high technology equipment, controls and components that purify water,
More informationModel Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
Model 1500 Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 Installation Instructions... 4 Start-Up Instructions...
More informationTTV Series. Softening Water System. Installation, Operation and Maintenance Manual. Revised 01/17/13
TTV Series Softening Water System Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules and operating instructions before first use of product. DEALER NAME: DEALER PHONE
More informationAssembled Engineered Systems. Softeners Filters Specialty Systems
Softeners Filters Specialty Systems Standard Features Quick Connect Features for Ultimate Convenience The quick connect bypass included with every unit comes standard with both 90 3 /4 " elbows and straight
More informationOwner s Manual. H151 HE - High Efficiency Water Softening System
H151 HE - High Efficiency Water Softening System Owner s Manual Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin 53597-2509 Web: www.hellenbrand.com Email: info@hellenbrand.com
More informationADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual
ADVANCE Backwashing Filters and Tannin Filter Installation Instructions & Owner s Manual Ta b l e o f Co n t e n t s : Preinstallation Instructions Page 1 Bypass Valve Page 1-2 Installation Page 3-4 Sulfur
More informationSignature Series. Duplex Softener Service Manual
Signature Series Duplex Softener Service Manual Control Start-Up Procedures System Overview Softener Slave Unit #2 (Forward Flow) Shuttle Valve Master Softener Slave Unit #1 (Reverse Flow) Connection to
More informationMASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units
MASTER Water Conditioning Corp. Installation and Operation Manual MCA Combination Series Residential Units February 2011 Table of Contents Page No. Topic Description 1 Model # and Packaging Packaging Information
More informationIron Gate Air Pump System Manual
Iron Gate Air Pump System Manual Installation and Operating Instructions Iron Gate Iron Filter System Manufactured by: R.E Prescott Co., Inc. 10 Railroad Avenue Exeter, New Hampshire 03833 Phone: (603)
More informationInstallation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners
Installation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners 115 N.W. Van Buren Topeka, KS 66603 Phone: 785-234-5551 Toll-free: 800-880-2022 Toll-free Fax: 800-269-3478 TABLE
More informationModel Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
Model 2850 Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 Installation Instructions... 4 Start-Up Instructions...
More informationWater Specialist 1 & 1.25 Motorized Alternating Valve
Water Specialist 1 & 1.25 Motorized Alternating Valve Allows for twin alternating system Low voltage drive assembly controlled by valves circuit board Utilizes WS1 and WS1.25 Control Valve Fittings Full
More informationWater Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25
Water Specialist Control Valve Series Model: WS.25 Control Valve Series Model: WS.25 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training
More information255 Valve Specifications
255 Valve Specifications imagination at work Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop... 15.5 (3.52 m 3 /h) Backwash @ 25 psi (1.72 ) drop... 6.0 (1.36 m 3 /h) Service... Cv=3.99
More informationSIMPLEX PREMIUM WATER SOFTENER INSTALLATION AND USER GUIDE
SIMPLEX PREMIUM WATER SOFTENER INSTALLATION AND USER GUIDE 1 TABLE OF CONTENTS 1) Installation... 2 1.1) Pre-installation instructions... 2 1.2) General Installation and Service Warnings... 2 1.3) Site
More information