MTX and WPX Turbine Flowmeters
|
|
- Hugh Johnson
- 6 years ago
- Views:
Transcription
1 Principle of Operation Liquid enters the precision metering insert containing the turbine rotor. The liquid pressure drives the turbine rotor rate of rotation proportional to the volumetric flow rate. The rotor's rotation is magnetically coupled to a hermetically sealed indicator or indicator/transmitter. igure 1. MTX with totalizing register igure 2. WPX with totalizing register igure 3. MTX /4 with totalizing register and standard calibrated contact closure ccessories - rate of flow indicators - totalizers - batch controllers enefits Saves Space Very compact size Lightweight lexible and Unique Design Reliable dd pulse transmitters without downtime Modular construction allows ease of service and field repair Power not required for mechanical version Sealed register prevents condensation or fogging One internal moving part 1
2 Technical Information unctional Specifications luid Types Liquid Maximum Pressure 227 psig (15 bar) luid Temperature 32 to 120 (0 to 49 C) or 32 to 250 (0 to 121 C) Registration U.S. Gallons Outputs See Table 1 and Table 2 Mechanical Register Non-resettable Total Magnetically coupled-direct reading lectronic transmitter option Magnetically coupled activated reed switch contact closure Reed switch rating: resistive - 3 Watts DC, 0.2 mp 30 VDC max (Model 840) Pulse transmitter with register option Power Supply: 30 VDC max, m Signal Output: non-symmetrical square frequency pulse train equal to supply voltage (Model 860) Performance Specifications ccuracy Repeatability % of rate % of rate low Turndown Ratio see Table 1 or Table 2 low Range see Table 1 or Table 2 Physical Specifications Materials of Construction Case ¾ - 1½ rass 2-10 poxy coated cast iron Measuring Chamber Polystyrene to 120 Noryl to 250 Polyethersulfone for Models 210 and 221 Rotor Polystyrene to 120 Noryl to 250 Polyamid for Models 210 and 221 langes Cast Iron for 2 to 10 size O-ring seals PDM Register Housing Plastic, ronze, luminum Connections & Mountings Mounting Positions MTX Series: Horizontal with register up WPX Series: Horizontal with register up or vertical nsure meter remains full. Typical Straight Pipe Upstream: 5 x D Requirements Downstream: 3 x D Process Connections MNPT: ¾ to 1½ sizes lange: 2 to 10 sizes lectrical Connection or optional electronic pulse transmitter(model 860) and reed switch (Model 840) Options Digital pulse transmitters and reed switch contact closure 2
3 low Ranges/Dimensions - MTX Series Water low Rates at Standard Conditions 60 o Minimum and maximum flow rates to achieve accuracy Optional Outputs MODL 122, , 433, ,421 Meter Size low rates (GPM) Contact Closure Reed Switch Pulse Transmitter Pulse Transmitter Model 840 Model 860 Model 860 inch min max gallons/contact gallons/contact full scale frequency(hz) pulses/gallon ¾ or 100 Cold /Hot Cold-61.89/Hot or ½ or or Table 1 ¾ to 1 ½ Sizes 2 Size -3 C { -1-2 igure 4 igure 5 Sizes ¾ 1 1 ½ 2 Threads/flanges 1 NPT (25.4) 1 ¼ NPT (31.75) 2 NPT (50.80) 6 ½ (165.10) -1 olt Holes # 4-2 olt Holes dia. 5/8 (15.88) -3 olt Holes dia. 4 ¾ (120.65) ore dia. ¾ Nominal 1 Nominal 1 ½ Nominal 2 Nominal C Length 7 ½ (190.50) 10 ½ (266.70) 12 (304.80) 10 ¾ (273.05) D Width3 ¾ (95.25) 4 (101.6) 5 ½ (139.70) 6 ½ (165.10) * Height 6 (152.40) 7 ¼ (184.15) 8 ¾ (222.25) 3 1/8 (79.37) Center line to base 1 ¼ (31.75) 1 ½ (38.10) 1 ¾ (44.45) 3 1/8 (79.37) Weight lbs. (kg) 4 ½ lbs (2.04) 6 ½ lbs. (2.9) 11 ½ lbs. (5.2) 27 ½ lbs. (12.5) *or 123/420 water meters add 1 ½ Table 2 inches (mm) 3
4 Pressure Drop Curves MTX Models 123, 414, 420, and 433 WPX Model 221 Sizes 3/4 to 10 Table 3 4
5 low Ranges/Dimensions - WPX Series MTX and WPX Turbine lowmeters Water low Rates at Standard Conditions 60 o Minimum and maximum flow rates to achieve accuracy Optional Outputs Meter Size low rates GPM Reed Switch Model 840 Pulse Transmitter Model 860 Pulse Transmitter Model 860 inch min max gallons/contact full scale frequency pulses/gallon cold hot cold hot cold hot /100 10/ / / / / / / / / / / Model 221 Table 4 C G D Model 210 igure 6 C G D igure 7 Model Cold and Model Hot Model Cold and Model Hot Size lange 6.5 (165.1) 7.87 (199.99) 8.66 (219.96) (284.99) 13.4 (340.36) 16 (406.40) olt holes # olt hole diameter 0.63 (15.88) 0.63 (15.88) 0.63 (15.88) 0.75 (19.05) 0.75 (19.05) 0.88 (22.23) ore circle diameter 4.75 (120.65) 6.0 (152.40) 7.5 (190.5) 9.5 (241.3) (298.45) (361.95) ore diameter C 2 Nominal 3 Nominal 4 Nominal 6 Nominal 8 Nominal 10 Nominal Length D 7.87 (199.90) 8.9 (226.06) 9.8 (248.92) 11.8 (299.72) 13.8 (350.52) 17.7 (499.5)* Width 6.5 (165.1) 7.87 (199.99) 8.66 (219.96) (284.99) 13.4 (340.36) 16.0 (406.4) Height Model (198.12) 9.2 (233.68) 9.67 (245.62) (346.71) (374.65) 17.3 (439.42) Height Model (274.32) 11.5 (292.1) 12.2 (309.88) (361.95) 15.3 (388.62) (442.98) Center to base line G 2.95 (74.93) 3.7 (93.98) 4.17 (105.92) 5.3 (149.86) 6.4 (162.56) 8.0 (203.20) Weight lbs. (kg) 22.5 (10.2) 31.0 (14.06) 42.8 (19.41) (32.5) 99 (44.9) 238 (107.96) inches (mm) Table 5 5
6 Ordering Information Please provide completed application data sheet (found at to allow us to confirm selection. 1. Confirm minimum and maximum flow ranges to maintain stated accuracy from Table 1 or Table 4 are within your requirements. 2. Select meter size. 3. Confirm pressure drop from Table Select flowmeter with register from below. Part # Part # MTX 60480P P P P P P P G P P P P P P G P P P P P P G P P P P P P P P236 WPX 60480P042N 60480P P043N 60480P P044N 60480P P045N 60480P P046N 60480P P047N 60480P P P236 Description 3/4 Model 123, 120 O with totalizing register 3/4 Model 122, 250 O with totalizing register 3/4 Model 413, 250 O with totalizing register and contact closure 3/4 Model 420, 120 O with totalizing register 3/4 Model 421, 250 O with totalizing register 3/4 Model 433, 120 O with totalizing register and contact closure 3/4 Model 444, 250 O with totalizing register and contact closure 1 x 3/4 250 O Couplings set 1 Model 123, 120 O with totalizing register 1 Model 122, 250 O with totalizing register 1 Model 413, 250 O with totalizing register and contact closure 1 Model 420, 120 O with totalizing register 1 Model 421, 250 O with totalizing register 1 Model 433, 120 O with totalizing register and contact closure 1-1/4 x O Couplings set 1-1/2 Model 123, 120 O with totalizing register 1-1/2 Model 122, 250 O with totalizing register 1-1/2 Model 413, 250 O with totalizing register and contact closure 1-1/2 Model 420, 120 O with totalizing register 1-1/2 Model 421, 250 O with totalizing register 1-1/2 Model 433, 120 O with totalizing register and contact closure 2 x 1-1/2 250 O Couplings set 2 Model 123, 120 O with totalizing register 2 Model 122, 250 O with totalizing register 2 Model 413, 250 O with totalizing register and contact closure 2 Model 420, 120 O with totalizing register 2 Model 421, 250 O with totalizing register 2 Model 433, 120 O with totalizing register and contact closure Model 840 calibrated contact closure (reed switch) Model 860 digital pulse transmitter 2" Model 221, 120 O with totalizing register 2" Model 210, 250 O with totalizing register 3" Model 221, 120 O with totalizing register 3" Model 210, 250 O with totalizing register 4" Model 221, 120 O with totalizing register 4" Model 210, 250 O with totalizing register 6" Model 221, 120 O with totalizing register 6" Model 210, 250 O with totalizing register 8" Model 221, 120 O with totalizing register 8" Model 210, 250 O with totalizing register 10" Model 221, 120 O with totalizing register 10" Model 210, 250 O with totalizing register 840 Model 840 calibrated contact closure (reed switch) (Model 420 & 421 only) 860 Model 860 digital pulse transmitter 6 Options Digital pulse transmitters (Model 860) Reed switch contact closures (Model 840) Set of inlet/outlet couplings TUR- Rev. D 2002 Venture Measurement 01/03 ll rights reserved. ll data subject to change without notice.
NIAGARA. Series WPX. Installation, Operation & Maintenance Manual. Models 210 and 222. Series WPX
NIAGARA M212 Rev. F Series WPX Models 210 and 222 Installation, Operation & Maintenance Manual Model 210 hot Sizes 2, 3, and 4 Sizes 6, 8, and 10 (red) Models 222 cold Sizes 2, 3, and 4 Sizes 6, 8, and
More information25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS
TS- Rev. B Type S lowmeters 1, 1 1 2 & 2 mm (1 in), mm (1-1/2 in) & mm (2 in) TYPE S LOWMETERS WITH MODEL 7 AND 8 SERIES REGISTERS 1-1/2" Type S with Model 7 Register SPECIICATIONS 1" Type S with Model
More informationM SERIES Multi-Jet Cold Water Meter
M SERIES Multi-Jet Cold Water Meter /4 1 1-1/2" 2" Maximum Flow GPM 0 0 1 Minimum Flow GPM.2.7 1. 2.0 Maximum Operating Pressure 0 psi Maximum Operating Temperature F ( C) Also Available in Hot Water Applications
More informationOMP POSITIVE DISPLACEMENT FLOWMETERS
OMP POSITIVE DISPLACEMENT FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Flow Ranges from 0.53 to 26 GPH to 4 to 92 GPM Handles Viscosities to 1,000,000 cps Pressure Ratings
More informationINDUSTRIAL DYNAMICS CO
TS-150 Rev. B MP Oscillating Piston Flowmeter: 12.7 mm (1/2" Type MP) 25.4 mm (1" Type MP) 50.8 mm (2" Type MP) 76.2 mm (3" Type MP) TYPE MP OSCILLATING PISTON FLOWMETER 2 " Type MP with 800 Series Register,
More informationTYPE MP OSCILLATING PISTON FLOWMETER
TS-150 (G) TYPE MP OSCILLATING PISTON FLOWMETER Flow Rates of 3.8 to 1,140 Liters/Min. (1 to 300 gpm) Accuracy of ±0.5% of Rate ±0.1% Repeatability Magnetically Coupled Output Shaft Proven Reliable Oscillating
More informationOMP Positive Displacement Flowmeters
Flow Ranges From 0.53 to 26 GPH Through 4 to 132 GPH Handles Viscosities to 1,000,000 cps Handles Viscosities to 1,000,000 cps Low Head Loss Oval Gear Design OMP Series Medium & High Flow Meters OMP-1
More informationTURBINE METERS - WP Series
TURBINE METERS - WP Series Operating Pressure 150 psi Maximum Operating Temperature Cold Water 105 F (40 ) 3 Layers Epoxy Coating SIZE 2" 3" 4" 6" 8" Max. Flow Rate GPM 400 850 1100 2600 4400 Transition
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationTechnical Data. Series Oval Flowmeter. Model 9400
Technical Data Series Oval Flowmeter Model 9400 General The Brodie 9400 Series Oval Flowmeters, Models 9402 through 9459 (sizes 1/2-3 ), are mechanical, positive displacement meters designed for use in
More informationTransmitting Transducer. Gas/Air Velocity Range:
RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationRIM20 Rotor Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationModel G6-S3. Repeatability ±0.02%
Issue/Rev. 0.6 (2/07) Smith Meter TM PD Rotary Vane Meter 6" Steel Model G6 Specifications Bulletin SS01014 The Smith Meter TM Model G6 Meter is a 6", double-case, straight-through (S3 through S8) or angle-type
More informationVIM20 Vortex Insertion Flowmeter
VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,
More informationG2 Industrial Grade Meters
G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
PART DESIGN DIRECTIVE. QUALITY ASSURANCE SECTION 530 METERS AND GAGES A. Comply with applicable UL standards pertaining to meters and gages and with applicable portions of ASME and Instrument Society of
More informationA1 Commercial Grade Meters
A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like
More informationPanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits
Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to
More informationArmstrong In-Line and Insertion Vortex Flow Meters
Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line
More informationFeatures/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS
Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed
More informationKDM ARMORED FLOW METER & SWITCH
KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature
More informationSpiraflo Steam flowmeters
Spiraflo Steam flowmeters Using a Spiraflo steam meter from Spirax Sarco will enable you to measure steam use accurately under all load conditions. It will provide vital information on usage and associated
More informationModel MVR. Model MVR. Materials and Specifications. Magnetic Drive Vertical Turbine Meters Sizes 3/4", 1", 1-1/2", 2", 3", 4" and 6" Features
Magnetic Drive Vertical Turbine Meters Sizes 3/4", 1", 11/2", 2", 3", 4" and 6" Features APPLICATIONS: Measurement of water for residential, commercial, industrial and residential fire applications, where
More informationA1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS
COMMERCIAL GRADE METERS Look for the silver label! Look for the silver label! COMMERCIAL GRADE METERS Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters
More informationCONTOIL VZFA/VZOA , versions for higher requirements / applications
CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing
More informationHydro-Flow 2200 Fixed Insertion Vortex Flow Meter
A trademark of Spirax Sarco, Inc. Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2200 fixed insertion vortex flow meter was designed specifically for water flow measurement,
More informationQBV SERIES Butterfly Valves
QV SERIES utterfly Valves KEY HIGH VUUM PROUTS, IN.'s QV Series butterfly valves are designed and manufactured to offer reliable performance, be versatile and offer an economic benefit. These valves have
More informationTurbine flowmeters Series TM
Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure
More information9400 Series Oval Flowmeter
Design Specifications DS9400 Revision 03 9400 Series Oval Flowmeter High accuracy Simple, durable construction Low maintenance requirements Easy access 3 piece design Choice of materials of construction
More informationFlow meter Type Recordall (RCDL)
Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Flow meter Type Recordall (RCDL) Bronze model Features
More informationThe EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.
Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationISTEC MAGNETIC METERS
ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE
More informationRosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries
Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering
More informationDOR Insertion Paddle Wheel Flowmeter
Benefits and Features Flow Range: 5.5 180 GPM to 25,000 800,000 GPM Flow Velocity Range: 1.0...33.0 ft/s pmax: 1160 PSI tmax: 300 F Connection: 1½" NPT, 2" NPT Male, R 1½, & R 2 Male for Pipe Sizes: 1½"...100"
More informationType 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal
Positive displacement flow fitting for continuous and batch control High accuracy ± 0.5% 1/2 TO 4 (DN 15 to 100) INLINE Quarter Turn technology For highly viscous fluids Electronics for indication, monitoring,
More informationA1 Commercial Grade Meters
A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like
More informationFlow Measurement & Control Solutions
BTU Meters Flow Meters Remote Displays Radiator Valves Balancing Valves Flow Measurement & Control Solutions TABLE OF CONTENTS BTU Meters 4000 Series...3 Chip Card System 5000 Series...4 Super Jet Water
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationKEL DIFFERENTIAL PRESSURE FLOWMETERS
KEL DIFFERENTIAL PRESSURE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Rugged Metal Construction Flow Rate to 2000 GPM Linear Scale For Horizontal or Vertical Pipes Threaded
More informationCTR Series. Turbine low meters with conditioned output and built-in loading valve. Up to. Output Options. Features. Hydraulic measurement and control
CTR Series Turbine low meters with conditioned output and built-in loading valve Milwaukee, WI 323, USA Tel: +1 (414) 769-6400 sales-us@webtec.com St. Ives, Cambs. PE27 3LZ, UK Tel: +44 (0) 1480 397 400
More informationMidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin
MidFlow Model PT / Fuel Oil Flowmeters135 Sliding Vane Meters DN 25-50 (1-2 ) _ 135 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments MidFlow Model PT positive displacement sliding vane type liquid
More informationBARTON 7400 Precision Gas Turbine Flow Meters
TECHNICAL SPECIFICATIONS BARTON 7400 Precision Gas Turbine Flow Meters BARTON Model 7400 Precision Turbine Flow Meters are designed for gas service in a wide range of industrial, commercial, pipeline and
More informationFLOWMETER (SMALL CAPACITY) METER SIZE 80, 81
UF- FLOWMETER (SMALL CAPACITY) METER SIZE, GENERAL SPECIFICATION GS.No.GBL--E GENERAL The UF-II Series is a new positive displacement flowmeter developed specifically to serve as the heart in loading facilities
More informationBM SERIES METERS PRECISION POSITIVE DISPLACEMENT METERS THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING INDUSTRY LEADING ACCURACY (+/-.
BM SERIES METERS PRECISION POSITIVE DISPLACEMENT METERS THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING INDUSTRY LEADING ACCURACY (+/-.05% * ) 110 TO 0 LPM (30 TO 1000 GPM) FLOW RATES * subject to meter
More informationTECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale
TECHNICAL SPECIFICATIONS Measuring Accuracy ±2% of full scale Repeatability ±0.5% of full scale Flow Measuring Range 1/2 porting: 0.5 15 GPM (2 60 LPM) 3/4 1 porting: 1.5 50 GPM (60 200 LPM) Turn Down
More informationmacnaught flow measurement
macnaught flow measurement solvent flow meters macnaught.com.au flow meters solvent macnaught flow measurement The "S" range of oval gear fuel and oil meters from Macnaught are positive displacement oval
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationG2 SERIES INDUSTRIAL GRADE METERS
Industrial Grade Meters INDUSTRIAL GRADE METERS The unique modular approach of the Industrial Grade Meter line allows you to design a meter to match your specific application. Turbine choice depends on
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationPRECISION METERS & ACCESSORIES
PRECISION METERS & ACCESSORIES Sotera Precision Meters incorporate oval gear technology, eliminating metalto-metal contact within the measuring chamber. This unique design promotes minimal wear, sustained
More informationMCS-203 Dancer Control
lectric rakes Tel: (O11) 4222-5040 ax: (011) 4201-2478. System eatures ull roll to core control Consistent tension, even during flying splices, rapid starts and emergency stops liminates web flutter to
More informationIndustrial Turbo Meters, Sizes 2" through 6"
Industrial Turbo Meters Sizes 2" through 6" TUR-UM-00530-EN-19 (October 2014) User Manual Industrial Turbo Meters, Sizes 2" through 6" User Manual CONTENTS Scope of the Manual 5 Specifications 5 Product
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationINDUSTRIAL METER CATALOG version seven
INDUSTRIAL METER CATALOG version seven TABLE OF CONTENTS G Series Precision Meters... Build-Your-Own... 4 G Series Meter Number Reference... 5 Stainless Steel GBT, GIT & GNT... 6 Stainless Steel GBP, GIP
More informationMCS-203 Dancer Control
lectric rakes System eatures n ull roll to core control n Consistent tension, even during flying splices, rapid starts and emergency stops n liminates web flutter to allow better registration control n
More informationDOR INSERTION PADDLE WHEEL FLOWMETER
DOR INSERTION PADDLE WHEEL FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Installation in Line Sizes from 1-1/2 to 100 Inches Velocity Measuring Range 1-33 Ft./Sec. 316L Stainless
More informationDW PADDLE-BELLOWS FLOWMETER & SWITCH
DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationTX101/201 Insertion Turbine Instructions
TX101/201 Insertion Turbine Instructions General Information Ruby bearings and a non-drag pick-off give these adjustable insertion turbine flow sensors a wide flow and long life. A sensor detects the passage
More informationVortex Flow Meter Model DVH
Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400
More informationTX101/201 Insertion Turbine Instructions
TX101/201 Insertion Turbine Instructions General Information Sapphire bearings and a non-drag pick-off give these adjustable insertion turbine flow sensors a wide flow and long life. A Hall-effect device
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationFluxi 2000/TZ Turbine Gas Meter
Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The
More informationF-2500 SERIES VORTEX METER
F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter
More informationModel Horizon. Horizon. Horizontal Turbine Meters Sizes 1-1/2" through 10" NOTICE OF DISCONTINUATION, Effective October 2011
Model tal Turbine Meters Sizes 1-1/2" through 10" NOTICE OF DISCONTINUATION, Effective October 2011 Mueller Systems has discontinued new sales of our meter line in an effort to introduce new metrology
More informationPositive displacement flowmeter for continuous flow measurement
8070 Positive displacement flowmeter for continuous flow measurement High accuracy Medium with high viscosity Mounting and dismounting of the electronics by a quarter-turn Connection to Bürkert devices
More informationDVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max
Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C
More informationVolumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas
Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate
More informationRMG Meßtechnik GmbH. Publication No E
Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationDW PADDLE-BELLOWS FLOWMETER & SWITCH
DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or
More informationRotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching
ROTORFLOW INTRODUCTION RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching Bright, visual indication with choice of pulsed DC output, or adjustable 1 amp switched output
More informationVORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter
R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up
More informationNC State University Design and Construction Guidelines Division 23 Energy Management
1.1 Purpose A. The following guidelines provide the methodology and requirements to assure that designs meet NC State standards for campus utility metering. 2.1 General Requirements A. Meters shall have
More informationDPT TARGET TYPE FLOWMETERS
DPT TARGET TYPE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control S3 Patented Target/Leaf-Spring Design Minimal Wear Components 1.5-8 to 225-500 GPM Water Line Sizes 3/8 to 3" Wide
More informationMADE IN THE USA BACKFLOW PREVENTERS
MADE IN THE USA BACKFLOW PREVENTERS TABLE OF CONTENTS Selection Guide........................................................................3 Double Check Valve (Series 40-100)......................................................4,5
More informationInsertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT
TECHNICAL PRODUCT INSTRUCTION SHEET Insertion turbine OVERVIEW These insertion flow transducers provide a cost effective and simple means of measuring the flow of a wide range of low viscosity liquids.
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationLiquid Turbine Flowmeters
NUFLO Liquid Turbine Flowmeters Accurate Flow Measurement In 1957, this flowmeter was developed with a tungsten-carbide shaft and bearing to withstand the rugged conditions of the oil field. Over the years,
More informationORIMAS Mass Flowmeter
Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical
More informationMULTI-JET WATER METERS
MULTI-JET WATER METERS INSTALLATION INSTRUCTIONS General Information Technical Data 3 Features 3 Applications 3 Dimensions 3 Pulse Rate 3 Pressure Loss Curve 3 Shipping Weight 3 Installation Position 4
More informationIM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL
IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist you in the operation
More informationPro-V Multivariable Flowmeter Model M24 In-line Vortex
Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an
More informationFLO-GARD INLINE FLOW SWITCHES RCM. RCM s broad range of flow switches provide economical solutions for equipment protection and automation.
FLO-GRD INLINE FLOW SWITCHES s broad range of flow switches provide economical solutions for equipment protection and automation. ll FLO-GRD flow switches provide high reliability design with no paddles,
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationVortex Flowmeter Model DVE
Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...
More informationThe full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at
Installation Manual INTRODUCTION The full WeatherTRAK Flow Installation and Maintenance Manual is available online at www.weathertrak.com General Description A WeatherTRAK Flow combines a hydraulic master
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationRange of Ultrasonic Flowmeters.
Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters
More informationPOSITIVE DISPLACEMENT FLOW METERS
POSITIVE DISPLACEMENT FLOW METERS ABOUT MACNAUGHT Macnaught Pty Ltd is a privately owned manufacturing company based in Australia, established in 1948. Macnaught s experience in Positive Displacement Flow
More informationo-ring, testing port and a convenient integral strainer.
OMNI TM T 1-1/,, 3,,, and OMNI T Meter Description 1-1/,, 3,,, and Sizes The OMNI T meter operation is based on advanced Floating Ball Technology (FBT). Totalization Mode AMR/AMI Mode Resettable Test Mode
More informationZDM Positive Displacement Flow Meter User Instructions
ZDM Positive Displacement Flow Meter User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com ZDM_manual_05/17
More informationProduct Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS
DESCRIPTION Turbine Flow Meter QuikSert The QuikSert in-line turbine flow meter was developed for liquid applications where accuracy and dependability are needed. QuikSert s stainless steel body incorporates
More informationPETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.
Double Case PD Flowmeters Technical Bulletin The trusted specialist manufacturer of high precision instruments that relies upon the accurate measurement of fluid volumes Trust in us Our Quality Counts
More informationWESAN WP WOLTMAN METER
WESAN WP WOLTMAN METER APPLICATION The bulk water meter WESAN WP can be used for measuring volumes of cold water (up to 50 C) in supply lines with high flow at low pressure loss. The measuring chamber
More informationFlow Sensors & Instruments
STAINESS STEE TURBINE FOWMETERS Serie X IG PRESSURE AND IG TEMPERATURE Principle of Operation The x range of Turbine Flowmeters meet the demand of most liquid measurement applications. They basically consist
More informationTechnical Data B20x. 8 BiRotor, APL. Model B201 [8 ] Model B203 [8 ] Model B204 [8 ] Model B205 [8 ]
Technical Data BiRotor, APL Model B201 [] Model B203 [] Model B204 [] Model B205 [] General The BiRotor Meter is a positive displacement meter utilized in the most demanding applications requiring accuracy,
More informationIndustrial OG meter series IOG Inline and flanged oval gear meter
Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Industrial OG meter series IOG Inline and flanged oval
More informationHydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual
Hydro-Flow Model 00 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines Mechanical Drawing:
More information