TRANSFORMER REPLACEMENT

Size: px
Start display at page:

Download "TRANSFORMER REPLACEMENT"

Transcription

1 Location Bowling Green, Ohio Electrical Engineering, Inspection, Construction Administration $300,000 Size 1 12/16 MVA Transformer Replacement Professional Services 2015 Construction: 2016 Project Team Daniel L. Knott, P.E., Project Manager Joel R. Sharrit Timothy J. Nelson, LEED AP Gregory N. Chipps TRANSFORMER REPLACEMENT City of Bowling Green/Southeastern Container The City of Bowling Green has retained the services of PDG to provide engineering design services to replace one (1) of two (2) of the City s 69/4.16 KV transformers at their Southeastern Container customer substation in the City of Bowling Green. The project includes the specification and installation of a transformer of a higher rating 12/16 MVA to replace one (1) of the existing 7.5/9.4 MVA transformers. Presently, the customer load typically exceeds the capacity of one of the transformers. The concern of a failure of one of the 30 plus year old transformers has lead the City to decide to replace one of the transformers at this time. The replacement will require close coordination of the plant outages in that the facility operates on a 24-hour, 7 day per week schedule. Shut down can only occur on Holidays and are typically limited to the holiday itself. The replacement also includes the upgrade of the transformers secondary underground cable circuit to increase the capacity to the 5 KV switchgear as well more... Reference City of Bowling Green John Rehm

2 Transformer Replacement as modifications to the protective relaying system. The new transformer will be installed in the same location as the transformer it will replace. The location and connection requirements were closely analyzed to determine modification requirements and the effect on the schedule for installation. The equipment delivery and contractor work schedule will require close coordination in that the transformer is planned to be set in place the day that it arrives reconnecting immediately to limit the outage time. A detailed listing of the steps required for the removal and installation has been developed to determine the timing schedule and to ensure all work items are prepared for and scheduled.

3 Total Build-out Over 17 years DESIGN BUILD PROJECT Location Bowling Green, Ohio Site/Civil Engineering, Stormwater Drainage Plan, Architectural, Structural, Mechanical, Electrical, Plumbing and Fire Protection Engineering $53 million PDG Project Team Phillip A. Whaley, P.E., Project Manager VEHTEK SYSTEMS AUTOMOTIVE BODY PANEL STAMPING PLANT PDG has completed engineering design through construction services for all four expansion phases for Vehtek Systems, Inc. Phase II, a 15,000 sq.ft. expansion of the plant, included installation of a 2,000 ton body panel press, 20 deep concrete press pit and foundation as well as a scrap steel reclaim tunnel. Phase III included a 50,000 sq.ft. expansion of the plant which included foundations, power distribution and cooling system extension for a robotic welding line for automotive body component sub-assembly. This Phase also included new pits and foundation for a new 600 ton press. Electrical distribution required installation of a new 12.47KV underground distribution system and service to the building. Design included pad mounted switch gear, 15KV underground cabling, switch disconnections and transformers in the plant. Project Relevance Multi-Phase Expansion Project Phase IV adds 419,000 sq.ft. of new space for a total completed building of 570,000 sq.ft. Electrical distribution more...

4 Vehtek Expansion Phases 1 4 PDG recently completed Phase IV of the expansion which houses hot stamping, blanking, and assembly processes, finished goods storage, and a new mechanical and electrical systems room. The low bay assembly and finished goods area was constructed from conventional steel structural systems and has an approximate clear height of 30 ft. with eight truck docks. The expansion also includes a high bay crane building for blanking operations and truck drive through loading bay, hot stamp operations with a mezzanine for the main electrical gear and control panels for the hot stamp lines. A 5,000 sq.ft. office addition and break room was also included in this Phase. Phase IV adds 419,000 sq.ft. of new space for a total completed building of 570,000 sq.ft. As part of Phase IV, the parking lot was expanded and a heavy-duty roadway around the plant was constructed. It also included coordination of a new intersection located at Poe Road.

5 Location Napoleon, Ohio Electrical Engineering, Survey $11 million Size 69,000/12,470 volt, 10 MVA substation Professional Services 2004 Construction: 2004 Project Team Daniel L. Knott, P.E., Electrical Engineer Joel Sharrit, Electrical Engineer CAMPBELL S SOUP AMCOR POWER DISTRIBUTION SYSTEM The Campbell Soup Company required electrical upgrades at its beverage plant to supply power to the new Amcor bottle making facility. The Amcor building required the installation of electric power distribution systems at both 4,160 volt KV and 480 volt. A new 69,000/12,470 volt, 10 MVA substation was installed to provide the power source. Due to the large electrical load of the Amcor facility, pad-mounted, oil-filled outdoor transformers were installed. The transformers included one 12.47/4.16KV, 3,750 KVA and two 12.47KV/480 volt, 3,750 KVA transformers. A line-up of 12.47KV outdoor switchgear was installed to supply the transformers. Indoor metal enclosed switchgear with draw-out circuit breakers were installed to supply the utilization equipment. The switchgear line-up was provided with metering and protective relaying devices for the protection of the equipment and arc flash requirements. PDG was responsible for the determination of the equipment requirements, specification of the equipment, and installation and wiring of the system. The outdoor oil-filled transformers were installed in a concrete oil containment area to meet EPA SPCC requirements. more... Project Relevance Beverage Plant Power Supply 4,160 Volt KV and 480 Volt Electric Power Distribution Systems Reference Mr. Patrick McCrate Program Manager AMCOR PET Packaging S. Highway M-52 Manchester, Michigan

6 Campbell Soup Amcor Power Distribution System This was a fast track, fully engineered, equipment purchase and detailed design project that was completed from beginning of design to power up in less than seven months. The design included equipment rating calculations, equipment specifications, structures design, foundations, oil containment, protective device, setting calculations, and grounding design cabling. Services included field check out, commissioning, start up and utility coordination.

7 Location St. Marys, Ohio Electrical Engineering $3.04 million Size 15 KV switchgear Tomlinson Substation Professional Services: 2011 Construction: 2012 Electric Utility Transmission and Distribution Circuit Professional Services 2009 PDG Project Team Daniel L. Knott, P.E., Project Manager Gregory N. Chipps, Design Technician SUBSTATION, TRANSMISSION AND DISTRIBUTION IMPROVEMENTS Tomlinson Substation PDG worked with the City of St. Marys to install a new outdoor 15 KV switchgear at the City s Tomlinson 69/12.47 Substation. The new switchgear will replace an existing indoor 15 KV switchgear which will be taken out of service. The project includes development of the specification of the switchgear and protective relaying, site layout, foundation design, electrical construction, and start-up assistance. Electric Utility 69KV Transmission Circuit and Distribution Circuit Underbuild The project included the design for the construction of approximately (1) one mile of 69KV overhead circuit and 12.47KV underbuild with State highway (expressway) crossing and permit. The circuits were extensions of existing circuits into a new area of the City. Project Relevance Switchgear Site Layout Reference Jerry Wolfe Electric System Superintendent 101 E. Spring Street St. Marys, Ohio ext fax jwolfe@cityofstmarys.net

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet DRAWING NUMBER INTRODUCTORY INFORMATION Important Notices Underground Plant Protection Information Code Clearances Commercial/Industrial Information Sheet Work Management Customer Projects Engineering

More information

TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY

TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY 2011-2020 P+ PowerPlus Engineering A Department of STAR Energy Services, LLC TEN YEAR PLANNING GUIDE 2011-2020 SHASTA LAKE ELECTRIC UTILITY CITY OF

More information

2701 INTERTECH DRIVE, YOUNGSTOWN, MAHONING COUNTY, INDUSTRIAL PROPERTY FOR SALE 143,789 SF on ACRES $4,300,000

2701 INTERTECH DRIVE, YOUNGSTOWN, MAHONING COUNTY, INDUSTRIAL PROPERTY FOR SALE 143,789 SF on ACRES $4,300,000 2701 INTERTECH DRIVE, YOUNGSTOWN, MAHONING COUNTY, 44504 INDUSTRIAL PROPERTY FOR SALE 143,789 SF on 20.177 ACRES $4,300,000 BUILDING OVERVIEW PARKER HANNIFIN FACILITY GEAR PUMP DIVISION Zoning - Industrial

More information

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

Schedules 1 to 4, Lot B: Extension of the Lessos Substation 1.0 LIGHTNING ARRESTORS 1.1 ZNO lightning arrester, 192 kv rated voltage, 10 ka nominal discharge current 2.0 CAPACITIVE VOLTAGE TRANSFORMER ea. 45 2.1 220 kv capacitive voltage transformer 220/ 3 / 0.11/

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

2701 INTERTECH DRIVE, YOUNGSTOWN, MAHONING COUNTY, INDUSTRIAL PROPERTY FOR SALE 143,789 SF on ACRES $4,300,000

2701 INTERTECH DRIVE, YOUNGSTOWN, MAHONING COUNTY, INDUSTRIAL PROPERTY FOR SALE 143,789 SF on ACRES $4,300,000 2701 INTERTECH DRIVE, YOUNGSTOWN, MAHONING COUNTY, 44504 143,789 SF on 20.177 ACRES $4,300,000 BUILDING OVERVIEW PARKER HANNIFIN FACILITY GEAR PUMP DIVISION Zoning - Industrial Light Manufacturing 143,789

More information

Max value Max life Range from. ($000) (Years) Pole Type

Max value Max life Range from. ($000) (Years) Pole Type Draft Handbook Vector Asset Description 1 Unit Maximum Maximum Life Max value Max life Max Asset Life Max Asset Life Range from Submitters Max Asset Life ($000) SUBTRANSMISSION Concrete Wood Concrete Wood

More information

AMPS SERVICES INC. INCORPORATED 2007 AMPS POWERLINE INC. INCORPORATED 2012

AMPS SERVICES INC. INCORPORATED 2007 AMPS POWERLINE INC. INCORPORATED 2012 AMPS SERVICES INC. INCORPORATED 2007 AMPS POWERLINE INC. INCORPORATED 2012 AMPS SERVICES & POWERLINE INC. AMPS Services Inc. is a consulting engineering firm, specializing in providing a full compliment

More information

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products Brochure Modular Systems wind portfolio Power Collection and Grid Connection products Wind portfolio Background ABB is one of the few suppliers that has been deeply involved in wind power segment development,

More information

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings: PRIMARY UNIT SUBSTATIONS SECTION 2701 PRIMARY UNIT SUBSTATIONS Ratings: lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts PAGE 1 ---JUNE 1, 1959 DESIGNED AND BUILT TO MEET YOUR OWN

More information

Mechanical, Electrical, Technology Engineering Firm

Mechanical, Electrical, Technology Engineering Firm Mechanical, Electrical, Technology Engineering Firm Established 1995 Current staff of forty-five Twenty engineers (12 registered P.E. s) Three Registered Communications Distribution Designers - RCDD s

More information

PORTISHEAD B POWER STATION

PORTISHEAD B POWER STATION PORTISHEAD B POWER STATION Portishead B Statistics: Main Building (General) Overall length: 704 ft. Overall width: 186 ft. Height above ground: 138 ft. (boiler house) Height above ground: 80 ft. (turbine

More information

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best. Medium Voltage Power Factor Correction Reactive Compensation Harmonic Filters POWER QUALITY Electrical Power Quality Management at its best. From electricity generation, transmission, thru its distribution

More information

ELEVATED STORAGE TANK EXPERIENCE

ELEVATED STORAGE TANK EXPERIENCE ELEVATED STORAGE TANK EXPERIENCE Butler Elevated Water Storage Tank new 150,000 gallon composite concrete/steel type elevated water storage tank, underground packaged pressurereducing station, and approximately

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,

More information

For Conduit Inspections

For Conduit Inspections Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit

More information

Fast-Track Design and Construction of Running Repair Shop for Metro-North Railroad

Fast-Track Design and Construction of Running Repair Shop for Metro-North Railroad Fast-Track Design and Construction of Running Repair Shop for Metro-North Railroad David W. Jacobs, PE Senior Construction Engineer MTA Metro-North Railroad Company Union Station 50 Union Avenue New Haven,

More information

Transformer Protection

Transformer Protection Transformer Protection Course No: E01-006 Credit: 1 PDH Andre LeBleu, P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 info@cedengineering.com

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Interconnection Feasibility Study Report Request # GI Draft Report 600 MW Wind Generating Facility Missile Site 230 kv Substation, Colorado

Interconnection Feasibility Study Report Request # GI Draft Report 600 MW Wind Generating Facility Missile Site 230 kv Substation, Colorado Executive Summary Interconnection Feasibility Study Report Request # GI-2016-6 Draft Report 600 MW Wind Generating Facility Missile Site 230 kv Substation, Colorado Public Service Company of Colorado Transmission

More information

FINAL FACILITY STUDY. 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1. September 10, 2010

FINAL FACILITY STUDY. 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1. September 10, 2010 FINAL FACILITY STUDY 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1 September 10, 2010 I. Introduction This is a revised facility study performed for Transmission Queue Request 2009

More information

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical New A Secondary Chill / 60V /36A Fused Disconnect For A Secondary Chill and Flex New B Secondary Chill / 60V / 36A B Secondary Chill Single 2.5 Conduit. Install New Additional 2.5 R.S.G. Conduit From 00A

More information

Senior Substation Project Lead Engineer

Senior Substation Project Lead Engineer Senior Substation Project Lead Engineer Are you ready to be a technology pioneer? Oil and gas factories 3000 meters underwater, heavy locomotive traction motors, electric vehicle chargers that deliver

More information

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability Convincing arguments for the outdoor modular switchgear bay Complete delivery from a single source

More information

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems www.switchgearpower.com Generator Controls, Paralleling Switchgear, LV Switchboards States Mfg. www.statesmfg.com Transformers (Substation

More information

Generation Interconnection Facilities Study For

Generation Interconnection Facilities Study For Generation Interconnection Facilities Study For Prepared for: Prepared by: SCE&G Transmission Planning May 27, 2015 TABLE OF CONTENTS General Discussion... Page 3 Generator Interconnection Specifications...

More information

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference 2010 / PM CM 21st Annual Conference The High-Velocity Edge: Achieving Operational Excellence ELECTRICAL / PM CM 2010 Conference Basic Electrical Rick Miller, PE, LEED AP RNM Engineering, Inc. Vanir Corp.

More information

MEDIUM VOLTAGE PRODUCTS

MEDIUM VOLTAGE PRODUCTS MEDIUM VOLTAGE PRODUCTS Anything is possible with MYERS POWER PRODUCTS PROTECT Protect your equipment and personnel from the elements and unforeseen electrical events with Myers Medium Voltage Products

More information

Modular integrated transportable substation (MITS)

Modular integrated transportable substation (MITS) Technical Data TD027002EN transportable substation (MITS) Contents Description Page Voltage regulation with bypassing........................................................ 2 Mobile MITS application...............................................................

More information

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear Robert J. Gustin Eaton Fellow Application Engineer, P. E. Southfield, Michigan Definitions Metal-enclosed load interrupter switchgear type ME Metal-enclosed switchgear is defined in ANSI C37.20.3-1987,

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

New Commercial Service Request-Job Process

New Commercial Service Request-Job Process New Commercial Service Request-Job Process HILCO Electric Cooperative, Inc. thanks you for the opportunity to be your electric provider. We are committed in providing you the best electric service promptly

More information

PREPARED DIRECT TESTIMONY

PREPARED DIRECT TESTIMONY Application No.: A.0-04- Exhibit No.: SDG&E-4 Witness: William V. Torre In the Matter of San Diego Gas & Electric Company s Application for Authorization to (1) to Participate in the Steam Generator Replacement

More information

Texas A&M Microgrid and Electrical System Study. Cushing Memorial Library & Archives

Texas A&M Microgrid and Electrical System Study. Cushing Memorial Library & Archives Texas A&M Microgrid and Electrical System Study Cushing Memorial Library & Archives Introduction of Texas A&M Microgrid Study Purpose Why are we studying the TAMU electrical system? Process How do we want

More information

Cloud-connected solution for utility-scale renewable power

Cloud-connected solution for utility-scale renewable power Cloud-connected solution for utility-scale renewable power Conext SmartGen TM Power System Global power conversion system for the next generation of PV and Energy Storage power plants connected to smart

More information

MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates

MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS Larry Vogt Manager, Rates Minimum Distribution System What is MDS? MDS is an analysis module of the cost-of-service study in which distribution investment

More information

Cloud-connected solution for utility-scale renewable power

Cloud-connected solution for utility-scale renewable power Cloud-connected solution for utility-scale renewable power Conext SmartGen TM Power System Global power conversion system for the next generation of PV and Energy Storage power plants connected to smart

More information

Network. ENMAX Power Corporation Network Planning & Design November 4, 2011

Network. ENMAX Power Corporation Network Planning & Design November 4, 2011 Network ENMAX Power Corporation Network Planning & Design November 4, 2011 ENMAX Fast Facts Service area of 1,044 square kilometers 1,738MVA Peak load (2009) Transmission System 266 km overhead 15km underground

More information

industrial groups We re working on your problems DIVISIONS Industrial Electronics Group, Inc. Industrial Surplus Group Industrial Marine Group, Inc.

industrial groups We re working on your problems DIVISIONS Industrial Electronics Group, Inc. Industrial Surplus Group Industrial Marine Group, Inc. industrial groups DIVISIONS Industrial Electronics Group, Inc. Industrial Surplus Group Industrial Marine Group, Inc. 850369 U.S. HIGHWAY 17 SOUTH POST OFFICE BOX 1870 YULEE, FLORIDA 32041-1870 Phone:

More information

3AP1 DTC for 145 and 245 kv

3AP1 DTC for 145 and 245 kv The Hybrid Solution 3AP1 DTC for 145 and 245 kv siemens.com/answers Solutions for switchgears and substations fully encapsulated h y b r i d Grade of encapsulation partly encapsulated not encapsulated

More information

Solar Farms: design & construction

Solar Farms: design & construction Solar Farms: design & construction Impacts to utility distribution systems John W. Gajda, P.E. Duke Energy Manager, DER Operations Support Agenda North Carolina s unique situation, which is coming to a

More information

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E S C ELECTRIC EUROPE LTD. Excellence Through Innovation Harnessing the Wind November 2011 Descriptive Bulletin 2000-42E Introduction Founded in 1911, S&C Electric Company is a global provider of equipment

More information

CUSTOMER/ TWIN ARROWS PROJECT

CUSTOMER/ TWIN ARROWS PROJECT A subsidiary of Pinnacle West Capital Corporation CUSTOMER/ TWIN ARROWS PROJECT V1 Facility Study Report APS Contract 52149 Prepared by: Arizona Public Service Company Transmission & Distribution Asset

More information

MK Panels. Manufacturer of marshalling kiosks, panels and related equipment

MK Panels. Manufacturer of marshalling kiosks, panels and related equipment Manufacturer of marshalling kiosks, panels and related equipment MK Panels Synbarr 210B Battery Street, Silverton, Pretoria, 0181 Phone: +27 12 8039663 Fax:+27 86 693 1054 http://www.synbarr.co.za About

More information

2011 Substation Refurbishment and Modernization. June 2010

2011 Substation Refurbishment and Modernization. June 2010 Z,1 Substatiort Refurbish~nent and Modernization NP 2011 CBA 2011 Substation Refurbishment and Modernization June 2010 Prepared by: Peter Feehan, P.Eng. 2.1 2011 Substation Refurbishment and Modernization

More information

100 MW Wind Generation Project

100 MW Wind Generation Project A subsidiary of Pinnacle West Capital Corporation 100 MW Wind Generation Project CUSTOMER FINAL Feasibility Study Results By Transmission Planning, APS December 21, 2007 Executive Summary This Feasibility

More information

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) About company The «Elektroapparat» plant starts its operation in 1922 as a plant manufacturing high-voltage electrical equipment. During the first two

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Conservation Voltage Reduction (CVR) Phillip Anderson P.E. Engineering Project Leader Research, Development & Deployment

Conservation Voltage Reduction (CVR) Phillip Anderson P.E. Engineering Project Leader Research, Development & Deployment Conservation Voltage Reduction (CVR) Phillip Anderson P.E. Engineering Project Leader Research, Development & Deployment Presentation Outline Background Information on CVR CVR Definition Voltage Control

More information

Recent Trades in Distribution System

Recent Trades in Distribution System Scientific Journal of Impact Factor(SJIF): 3.134 e-issn(o): 2348-4470 p-issn(p): 2348-6406 International Journal of Advance Engineering and Research Development Volume 2,Issue 3, March -2015 Recent Trades

More information

Power Products Division. Power Services Service underpins everything we do

Power Products Division. Power Services Service underpins everything we do Power Products Division Power Services Service underpins everything we do Business Overview ABB s Power Services is a support group to all power products and systems business units within ABB. We provide

More information

BUILT WITH INTEGRITY

BUILT WITH INTEGRITY WITH INTEGRITY Let us share our wealth of knowledge accumulated over three decades. We have equipped the material handling industry across North America with some of the most resilient cranes and crane

More information

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION

More information

Electric and Gas Safety. Walt Blackford, Outreach Manager 09 April 2018 Whidbey Island Growers Association

Electric and Gas Safety. Walt Blackford, Outreach Manager 09 April 2018 Whidbey Island Growers Association Electric and Gas Safety Walt Blackford, Outreach Manager 09 April 2018 Whidbey Island Growers Association Safety Moment (video) Electric and Gas Safety How Power Gets to Whidbey and How It Is Restored

More information

Grounding Of Standby & Emergency Power Systems

Grounding Of Standby & Emergency Power Systems July / August 2007 ELECTRICAL LINE 53 Grounding Of Standby & Emergency Power Systems By Andrew Cochran Power continuity is essential in many industrial and commercial installations where a trip out due

More information

March 18, Subject: Imperial Irrigation District 2014 Annual Progress Report - Rev 1

March 18, Subject: Imperial Irrigation District 2014 Annual Progress Report - Rev 1 Energy Division P.O. Box 937 333 E. Barioni Blvd. Imperial, CA 92251 www.iid.com March 18, 2014 Mr. Tracy Rolstad Chair, WECC Technical Studies Subcommittee Senior Power System Consultant Avista System

More information

Western Area Power Administration Rocky Mountain Region Annual Progress Report. Projects. Weld Substation Stage 04

Western Area Power Administration Rocky Mountain Region Annual Progress Report. Projects. Weld Substation Stage 04 Western Area Power Administration Rocky Mountain Region 2014 Annual Progress Report Projects Weld Substation Stage 04 Lovell Yellowtail 115-kV rebuild Curecanti 230/115-kV 150 MVA transformer Terry Ranch

More information

If You Can Produce It, We Can Move It. Custom engineered products for safe, reliable and efficient material handling.

If You Can Produce It, We Can Move It. Custom engineered products for safe, reliable and efficient material handling. MATERIAL HANDLING AND FABRICATED PRODUCTS If You Can Produce It, We Can Move It. Custom engineered products for safe, reliable and efficient material handling. Avon Engineering is recognized as a leader

More information

COGENERATION PLANT SWITCHGEAR REPLACEMENT IMPROVES SAFETY AND RELIABILITY WHILE MAINTAINING SERVICE TO CRITICAL LOADS

COGENERATION PLANT SWITCHGEAR REPLACEMENT IMPROVES SAFETY AND RELIABILITY WHILE MAINTAINING SERVICE TO CRITICAL LOADS COGENERATION PLANT SWITCHGEAR REPLACEMENT IMPROVES SAFETY AND RELIABILITY WHILE MAINTAINING SERVICE TO CRITICAL LOADS Rachel Mueller, Mayo Clinic Timothy Coyle, PCT, Inc. Presented to: Minnesota Power

More information

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

Wisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power

Wisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power Wisconsin Public Utility Institute June 28, 2017 Minimum Distribution Charges Larry Vogt Director, Rates Mississippi Power 1 Costs of Service vs. Cost Recovery Residential Service Example Assuming that

More information

Tradition. Technology. Innovation.

Tradition. Technology. Innovation. Tradition. Technology. Innovation. 2 Tradition. Technology. Innovation. 50433 IEM CorpBror1.indd 2 4/3/15 2:41 PM Today, IEM has expanded beyond Silicon Valley to supply specialized electrical equipment

More information

Seremban Gemas Electrified Double Track Project, Malaysia

Seremban Gemas Electrified Double Track Project, Malaysia Seremban Gemas Electrified Double Track Project, Malaysia Electrification Works at a Glance Electrification, the need of time. The need for efficient, eco-friendly and well-integrated public transport

More information

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 1 of 5. Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 2 Definitions 2 Not seen the definition for Inspector. But with, - Qualifications,

More information

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2012

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2012 Safety Services 16 th floor, Commerce Place Tel: 1-866-421-6929 10155 102 nd Street Fax: 780-427-8686 Edmonton, Alberta Canada T5J 4L4 STATISTICS ELECTRICAL INCIDENTS IN ALBERTA January 1 to December 31,

More information

IEEE-PES Chicago Chapter Presentation November 11, Smart Grid. Mike Born. Principal Engineer, Capacity Planning

IEEE-PES Chicago Chapter Presentation November 11, Smart Grid. Mike Born. Principal Engineer, Capacity Planning IEEE-PES Chicago Chapter Presentation November 11, 2009 Smart Grid Mike Born Principal Engineer, Capacity Planning Agenda 2 Smart Grid Brief Overview ComEd s Smart Grid Vision and Building Blocks Customer

More information

Customer Substation Manual

Customer Substation Manual Customer Substation Manual Table of Contents Section Page 2 of 81 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation

More information

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE 201 S. Anaheim Blvd. Page No. 3.2.1 A. GENERAL 1. The character of electric service available at any particular location should be ascertained by inquiry at the City's Electrical Engineering Division office.

More information

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE ADVISE DESIGN FOR ELECTROTECHNICAL EXCELLENCE IMPLEMENT ADVISE DESIGN FOR ELECTROTECHNICAL EXCELLENCE Gemitech was founded in 1990 and, in just a few short years, grew to be recognized as medium and IMPLEMENT

More information

Water Treatment Plant Historical Timeline

Water Treatment Plant Historical Timeline Water Treatment Plant Historical Timeline 1874 The citizens of the the Village of Evanston, with a population of 3500, started to build a communal water system. The system consisted of a 16 inch intake

More information

Manufacturing/Warehouse N 1425 East Rd. Hudson, IL

Manufacturing/Warehouse N 1425 East Rd. Hudson, IL Manufacturing/Warehouse HUGE REDUCTION $9,450,000 PROPERTY FEATURES 3 Miles North of Normal Sprinkler System w/ 20,000 Gallon Tank & Pump 3 External Loading Docks - 1 Internal Dock with Sunken Truck Loading

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

EL PASO ELECTRIC COMPANY (EPE) FACILITIES STUDY FOR PROPOSED HVDC TERMINAL INTERCONNECTION AT NEW ARTESIA 345 KV BUS

EL PASO ELECTRIC COMPANY (EPE) FACILITIES STUDY FOR PROPOSED HVDC TERMINAL INTERCONNECTION AT NEW ARTESIA 345 KV BUS EL PASO ELECTRIC COMPANY (EPE) FACILITIES STUDY FOR PROPOSED HVDC TERMINAL INTERCONNECTION AT NEW ARTESIA 345 KV BUS El Paso Electric Company System Operations Department System Planning Section May 2004

More information

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards Robert P. Hansen, P.E., PhD GE Specification Engineer Introduction Switchboards are a widely used type of equipment

More information

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP) Discipline Engineering Standard NSW Category General Title Reference Number PMP 01 (RIC Standard: EP 00 00 00 02 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards and

More information

MILLIGAN SOLAR PROJECT

MILLIGAN SOLAR PROJECT February 16, 2009 Page 1 of 18 A subsidiary of Pinnacle West Capital Corporation MILLIGAN SOLAR PROJECT FINAL Feasibility Study Report APS Contract 52115 Prepared by: Arizona Public Service Company Transmission

More information

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

Extra-High-Voltage SF 6 Gas-Insulated Switchgear Extra-High-Voltage SF 6 Gas-Insulated Switchgear Shuichi Sugiyama Masahiko Fujita Takahiro Shinohara 1. Introduction Due to location criteria and toughened restrictions on transportation, it has become

More information

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2013

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2013 Safety Services 16 th floor, Commerce Place Tel: 1-866-421-6929 10155 102 nd Street Fax: 780-427-8686 Edmonton, Alberta Canada T5J 4L4 STATISTICS ELECTRICAL INCIDENTS IN ALBERTA January 1 to December 31,

More information

132/11 kv, 25 MVA MOBILE SUBSTATION

132/11 kv, 25 MVA MOBILE SUBSTATION File name: Mob EN katalog1 Zagreb, 11.11.2014. Page: 1 od 9 Summary Mobile substation consists of two semitrailers. One trailer is for 132 kv equipment (HV equipment) and another trailer is for medium

More information

BEFORE THE NEW JERSEY BOARD OF PUBLIC UTILITIES

BEFORE THE NEW JERSEY BOARD OF PUBLIC UTILITIES EXHIBIT JC-2 BEFORE THE NEW JERSEY BOARD OF PUBLIC UTILITIES IN THE MATTER OF THE PETITION OF JERSEY CENTRAL POWER & LIGHT COMPANY PURSUANT TO N.J.S.A. 40:55D-19 FOR A DETERMINATION THAT THE OCEANVIEW

More information

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications Sectionalizing Rick Seeling Introduction Philosophy Pete Malamen Three Phase Reclosers High-Side Protection Specific Applications History Early 1970 s Small Substation Transformers

More information

Rex Healthcare Medium Voltage System Presentation APEC 2015 March 15-19, 2015

Rex Healthcare Medium Voltage System Presentation APEC 2015 March 15-19, 2015 Rex Healthcare Medium Voltage System Presentation APEC 2015 March 15-19, 2015 Maximizing the Efficiency of Hospital Distribution Systems Through the Use of Advancing Technology and Design Creativity MISSION:

More information

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION Roseville Electric SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION REVISED 04/25/18 Specifications for Residential Construction Revision List REVISION Date Page No. Description 03/20/00 6.1-6.2 Added Armorcast

More information

2013 ANNUAL PROGRESS REPORT

2013 ANNUAL PROGRESS REPORT March 1, 2013 Mr. David Franklin, Chairman WECC Technical Studies Subcommittee Southern California Edison 1 Innovation Way Pomona, CA 91768-2560 Mr. Enoch Davies WECC Technical Staff 155 North 400 West,

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to

More information

High Voltage Pad-mount Transformer

High Voltage Pad-mount Transformer High Voltage Pad-mount Transformer What is the High Voltage Padmount Transformer(HVPT) Substation? Traditional substation vs. HVPT HVPT History In order to reduce its outlay in distribution, Manitoba Hydro

More information

Garrett Ng, Head of Data Center Segment, Singapore

Garrett Ng, Head of Data Center Segment, Singapore ABB DATA CENTER FORUM 2017, 11 JULY 2017, TUESDAY ABB Data Center Service Digital Service? Be the Change to Make the Difference Garrett Ng, Head of Data Center Segment, Singapore Content Introduction ABB

More information

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE H U B B ELL L ABO R ATO R I E S CAPABILITY GUIDE INTRODUCTION Hubbell Power Systems, Inc. manufactures a wide variety of products for the electric utility, telecommunications, civil construction, transportation,

More information

355,100 Sq. Ft. Manufacturing/Warehouse Facility

355,100 Sq. Ft. Manufacturing/Warehouse Facility Industrial Manufacturing/Distribution Building, Pennsauken, New Jersey 355,100 Sq. Ft. Manufacturing/Warehouse Facility Manufacturing/Warehouse 336,500 sq. ft. Office/Finished Space 18,600 sq. ft. Divisible

More information

Design standards used : CMAA, CSA, AIST, AISE, OSHA, FEM, HMI, CWB, AWS, ANSI, ASME, ASTM, AGMA, NEC, NEMA, IEEE, UL, ISO

Design standards used : CMAA, CSA, AIST, AISE, OSHA, FEM, HMI, CWB, AWS, ANSI, ASME, ASTM, AGMA, NEC, NEMA, IEEE, UL, ISO Through innovation and cutting-edge technology, provide sound engineering solutions while improving equipment efficiency, reliability, and safety. Achieve the highest level of customer satisfaction throughout

More information

Building a 21 st Century Electric Grid. February 23, 2018

Building a 21 st Century Electric Grid. February 23, 2018 Building a 21 st Century Electric Grid February 23, 2018 1 DTE strives to provide customers with a 21 st century electric grid that is safe, highly reliable, affordable and accessible 2 Our investment

More information

Shippensburg University

Shippensburg University Shippensburg University 1871 Old Main Drive Shippensburg, PA 17257 SUPPLEMENT 1 Electrical Coordination Study Professional: Entech Engineering, Inc. 4 South Fourth Street P.O. Box 32 Reading, PA 19603

More information

A 500kV AIS Switchyard Rejuvenation in British Columbia using Hybrids

A 500kV AIS Switchyard Rejuvenation in British Columbia using Hybrids A 500kV AIS Switchyard Rejuvenation in British Columbia using Hybrids Author Company Email Presenter T.A. Messinger BC Hydro toly.messinger@bchydro.com E. Burt BC Hydro ed.burt@bchydro.com P.Glaubitz Siemens

More information

Ed rev.0 CATALOGUE SWITCHGEAR 2015

Ed rev.0 CATALOGUE SWITCHGEAR 2015 Ed. 2015 rev.0 CATALOGUE SWITCHGEAR 2015 SV24NC GENERAL SV24NC voltage metal enclosed switchgears for indoor use are constructed by placing standardized units side by side in a coordinated way. Insulation

More information

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1 THE SOUTH AFRICAN INSTITUTE OF ELECTRICAL ENGINEERS FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1 OVERVIEW : 1. Introduction to Distribution, Transmission and Generation

More information

Data Center Energy Saving using 5kV Distribution System Architecture. 18 Sep 2009

Data Center Energy Saving using 5kV Distribution System Architecture. 18 Sep 2009 Data Center Energy Saving using 5kV Distribution System Architecture 18 Sep 2009 Power Density Growing www.networkcomputing.com/crash course data center power.php Increasing Demands 1984 Bank of America

More information

Installation Instructions for Bike Fixtation. Bottle Fill and Bike Wash Stations Manual Rev. B

Installation Instructions for Bike Fixtation. Bottle Fill and Bike Wash Stations Manual Rev. B 15540 Woodinville Redmond Rd NE, Suite A-200, 2647 37th Woodinville, Ave. S Unit WA 1, Minneapolis 98072 MN 55406 Phone: 425.483.7000 Phone: 612-568-3498 Email: salesandsupport@sportworks.com E-mail: info@bikefixtation.com

More information

One-Fit,UFES, Reyrolle LM

One-Fit,UFES, Reyrolle LM EPDS SERVICE, SOUTH AFRICA, FRANS BOUWER, 2018. Retrofit Solutions One-Fit,UFES, Reyrolle LM AMEU Namibia,March 2018 Retrofit Agenda 1. Safety 2. One-Fit overview 3. UFES overview 4. Reyrolle LM-Switchgear

More information

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI

More information