Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

Size: px
Start display at page:

Download "Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical"

Transcription

1 New A Secondary Chill / 60V /36A Fused Disconnect For A Secondary Chill and Flex New B Secondary Chill / 60V / 36A B Secondary Chill Single 2.5 Conduit. Install New Additional 2.5 R.S.G. Conduit From 00A Circuit Breaker To New B Secondary Pump For New Feeder Demo Feeder in Single 2.5 Conduit And Replace With New Feeder Qty. 3 X 3/0 and Installed In Each Of Two Parallel Conduits and Flex New C Secondary Chill / 60V / 36A C Secondary Chill and Flex Reuse As Much As Practical. Refer to Project Specification #CP Rev. A, for additional requirements. 2. All notes apply to all pages. 3. Drawings are not to scale and indicated dimensions are approximate. Drawings are only intended to provide relative locations of pertinent equipment. equipment locations, conduit sizes, and routing are for reference only and may not be exact.. Contractor shall ensure that all work is in accordance with the latest version of the National Electrical Code and all other applicable State and local codes. 5. Contractor shall coordinate all work and power outages with owner. Contractor shall have only one chill water pump out of service at a time unless approved otherwise by owner. 6. Contractor shall be responsible for supplying all materials (junction boxes, pull boxes, flex, etc.) and labor as necessary for a complete installation and functional system whether shown on drawings or not. 7. All materials shall be U.L. Listed / Approved as applicable. 8. All power wiring shall be copper type THHN/THWN installed in rigid galvanized steel conduit. 9. Contractor shall permanently attach plastic engraved equipment identification labels (2 high min. white letters on black background) on all new equipment and on existing circuit breaker / fused disconnects. 0. All equipment shall have labels warning of High Voltage and Arc Flash Danger as required by NEC.. Contractor shall remove and dispose of existing s for East Energy Facility s A, B, and C s. Contractor shall supply and install new replacement ABB Model ACH-550 Enclosed Floor Mounted with integrated E-Clipse Bypass. New s shall having a minimum equipment spacing of.5 on both sides. 2. Contractor shall remove and dispose of existing supply feeders and motor wiring. Contractor shall supply new supply feeders and motor wiring as indicated on drawings. 3. Contractor shall install new 2.5 conduit in parallel with existing 2.5 conduit for supply feeder to new B Secondary.. Contractor shall be responsible for factory authorized start-up and programming of all s. 5. Contractor shall be responsible for maintaining a clean and safe working environment at all times. Contractor shall comply with all work and safety requirements of the University of SC. EAST ENERGY ONE LINE EAST ENERGY FACILITY ELECTRICAL ONE LINE RWR ENGINEERING, LLC Richard (Rick) W. Roof, P.E.

2 Johnson Controls BMS Panel A + -20MA - A A B + -20MA - B B C + -20MA - C C TO JOHNSON CONTROLS BUILDING MANAGEMENT SYSTEM CONTROL / INSTRUMENTATION INTERFACE A Secondary AI +2V DI Start / Stop B+ RS85 Comm. B Secondary AI +2V DI Start / Stop B+ RS85 Comm. A Secondary AI. Refer to Project Specification #CP Rev. A, for additional requirements. 2. Contractor shall be responsible for supplying and installing all conduit and signal wiring required to interface new A, B, and C Secondary Chill s at East and West Energy Facilities with existing Johnson Controls Building Management System. 3. Contractor shall be responsible for programming of all new s and existing Johnson Controls Building Management System for proper operation of secondary chiller water system. All Building Management System control interface and programming shall be performed by an authorized representative of Johnson Controls. All start-up and programming shall be done by a ABB factory authorized representative.. All control / signal interface cables shall be U.L. listed and rated for 600 volts. All set-up parameters shall be stored in keypads after all programming is complete. 5. motor thermal switch wiring on West Energy A, B, and C s shall not be reconnected to new s. motor thermal switch wiring shall be capped and insulated in motor connection housing. motor thermal switch wires shall be identified with a heat shrinkable label for future use. 6. All set-up parameters shall be stored in s keypad after all programming is complete. 7. Contractor shall install heat shrinkable wire labels on both ends of all Building Management System control / signal interface wiring cables. Cables shall be labeled as follows: A-SCWP-Speed B-SCWP-Speed C-SCWP-Speed A-SCWP-Start B-SCWP-Start C-SCWP-Start A-SCWP- RunFbk B-SCWP-RunFbk C-SCWP-RunFbk SCWP-RS85 SCWP-RS85 SCWP-RS85 +2V DI Start / Stop RS85 B+ N2 A- Comm. B+ RS85 Comm. Belden #27326A Typical Daisy Chain Connected RS85, 3 Wire or 2 Twisted Pairs 2 Ga., 600 Volt Belden #27325AS Typical SEE NOTE #5, Typ. EAST &WEST ENERGY FACILITY BLDG. MANAGEMENT SYSTEM INTERFACE DRAWING NO. #CP I

3 Wall High Voltage Switch Gear Approx. 20 Ft. Fused Disc. For A A, B, and C Secondary s To Be Replaced With New ABB Model ACH-550 With E-Clipse Bypass C 3 Conduit C Secondary Pump Transfer Switch 3 Conduit B 3 Conduit MCC 3 C.B. For B In Bottom Of Section 2.5 Conduit Install New 2.5 Conduit In Parallel With 2.5 Conduit Johnson Controls BMS Panel A MCC B Secondary Pump MCC Approx. 6 Ft. Other Equipment In This Area 3 Conduits C.B. For C In Third Section From End A Secondary Pump EAST ENERGY MAIN FLOOR EAST ENERGY FACILITY APPROXIMATE EQUIPMENT LAYOUT 2

4 Single 2 Conduit New A Secondary Chill 50 HP / 60V / 80A 250A A Secondary Single 2.5 Conduit Qty. X /0 Per Phase Qty. X # Ground Pull Box New B Secondary Chill 50 HP / 60V / 80A Fused Disconnect For B Secondary Chill Water Pump. Replace 300A Fuses With 250A KTSR Fuses. Single 2.5 Conduit Qty. X /0 Per Phase Qty. X # Ground Single 2 Conduit New C Secondary Chill 50 HP / 60V / 80A 250A Fused Disconnect For C Secondary Chill Single 2 Conduit Qty. X /0 Per Phase Qty. X # Ground. Contractor shall supply and install 250A KTSR (or equal) fuses in place of existing 300A fuses in supply feeder fused disconnect for B Secondary. 2. Contractor shall install and place into service the new for West Energy C Secondary first before replacing the s for A and B Secondary Pumps. 3. Contractor shall remove and dispose of existing Controllers (, enclosure, control relays, contactors, etc.) for West Energy Facility C. Contractor shall remove and return to owner all power fuses and Power Logic Modules in existing Controller. Contractor shall supply and install new replacement ABB Model ACH- 550 Enclosed Wall Mounted with integrated E-Clipse Bypass for West Energy C Secondary Pump. New shall having a minimum spacing of.5 off of wall.. Contractor shall remove and dispose of existing enclosures, contactors, control relays, etc. for existing West Energy A and B Secondary Chill controllers. Contractor shall remove and return to owner existing ABB s, Power Logic Modules, power fuses, and Lion Model IAMS Signal Isolation modules for West Energy A and B Secondary s. Contractor shall supply and install new replacement ABB Model ACH-550 Enclosed Wall Mounted s with integrated E-Clipse Bypass for West Energy A and B Secondary Pumps.. New s shall having a minimum spacing of.5 off of wall. 5. Contractor shall remove and dispose of existing supply feeders and motor wiring. Contractor shall supply new supply feeders and motor wiring as indicated on drawings. and Flex Qty. X /0 Per Phase Qty. X # Ground Single 2.5 Conduit and Flex Qty. X /0 Per Phase Qty. X # Ground Single 2 Conduit and Flex Reuse As Much As Practical Qty. X /0 Per Phase Qty. X # Ground 50 HP / 60V / 7.5A 50 HP / 60V / 7.5A 50 HP / 60V / 7.5A WEST ENERGY ONE LINE WEST ENERGY FACILITY ELECTRICAL ONE LINE RWR ENGINEERING, LLC Richard (Rick) W. Roof, P.E. 3

5 Stairs Johnson Controls BMS Panel Contractor Shall Disconnect And Demo Johnson Controls Power Logic Communication Panels In This Area That Are No Longer Being Used. 250A Fused Disconnect For C Located In This Panel C Secondary C Secondary Pump 50 HP 3 Conduits Instrumentation Conduit. 2.5 Conduit Electrical Gear In Basement B Secondary B Secondary Pump 50 HP 2 Conduit Floor Mounted A, B, and C s Shall Be Replaced With New Wall Mounted ABB Model ACH-550 s With E-Clipse Bypass. Contractor Shall Mount New s On Back Wall and Pour Sloped Concrete Edges to Concrete Pads. Contractor Shall Extend Concrete Pads to Back Wall. A Secondary Pump 50 HP 2 Conduits Pull Box On Basement Ceiling. Note Contractor Shall Field Verify That Feeders Cross In This Box 250A Circuit Breaker For A Located Upstairs In This Panel 2.5 Conduits Wall. Contractor shall install new s on back wall in approximate location of existing s.. WEST ENERGY BASEMENT Electrical Gear On Main Floor 300A Fused Disconnect For B Located Upstairs In This Panel. Note Fuses Shall Be Changed To 250A. Conduits Stub Up Into Bottom Of Electrical Panels Located On Main Floor WEST ENERGY FACILITY APPROXIMATE EQUIPMENT LAYOUT

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options Product Description The SED2 Electronic Bypass (E-Bypass) Options are companion packages for the family of SED2 Variable Frequency Drives

More information

Quick Connection Panel (QCP) Installation Guide

Quick Connection Panel (QCP) Installation Guide Quick Connection Panel (QCP) Installation Guide DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read this document first. The installer is responsible for compliance with National Electrical

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

PowerAir Compressor Installation

PowerAir Compressor Installation PowerAir Compressor Installation Applies to Models: P21-115 Volts P22, P32-230 Volts P52, P72-230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Model

More information

ClassicSeries Compressor Installation

ClassicSeries Compressor Installation ClassicSeries Compressor Installation Applies to Models: CL21-115 Volts CL22, CL32, CL52-208- 230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Note:

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE A WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL RENEWAL PARTS Supercedes: 150.7-RP1 (709) Form: 150.7-RP1 (810) MODELS YCRL0064, 0074, 0084, 0096, 0118, 016, 0156, 0177, 0198, 000, 030, 060, 0300, 0345, 0385,

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS Supersedes: 160.75-PW2 (508) Form 160.75-PW2 (311) FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS WIRING DIAGRAM CONTRACTOR ORDER NO. YORK CONTRACT NO.

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER

More information

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016 DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5 PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK PART 1 - GENERAL 1.1 GENERAL: SECTION 15150 MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK A. The Mechanical Contractor shall furnish to the Electrical Contractor for installation,

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Pedestrian Turnstile Type MPT 33 Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11

More information

METERING REQUIREMENTS

METERING REQUIREMENTS METERING REQUIREMENTS KUA will not accept a non-securable service trough entrance. That is, all enclosed conductors prior to the meter (line side) will be securable by and accessible to KUA personnel only.

More information

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD Part: VST ECS-CS3-310 Three Phase VST-ECS-CS3-110 Single Phase Executive Orders: VR-203 VR-204 Version: 1.1 NOTE:

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

Quick Start Guide TS 910 & TS 920

Quick Start Guide TS 910 & TS 920 Quick Start Guide TS 910 & TS 920 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999 /2600 Lighting Control Panels Installation and Setup Guide Revision 3. July 999 Phone:770-429-3043 http://www.triateklighting.com sales@triateklighting.com Installation Guide /2600 Lighting Panels Table

More information

LIFT STATION 11 ONE-LINE DIAGRAM

LIFT STATION 11 ONE-LINE DIAGRAM LAC JOB : 118-086 OSG-D-ELEC06.DWG LIFT STATION 11 ONE-LINE DIAGRAM DWG : SHEET : E15 33 47 NEW NEW GENERATOR PAD BOLLARD BOLLARD WETWELL ACCESS HATCH WETWELL OUTLINE HANDHOLE SEWER MANHOLE LIFT STATION

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

IRRIGATION RENOVATION PROJECT Construction Documents

IRRIGATION RENOVATION PROJECT Construction Documents P 10-49 TOUCHET VALLEY GOLF COURSE AND FAIRGROUNDS Dayton, Washington IRRIGATION RENOVATION PROJECT Construction Documents NOVEMBER 2015 Sheet Layout COVER IR0.1 PROJECT SUMMARY IR1.0 GOLF IRRIGATION PLAN

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 24 14 600 VOLT DRAWOUT SWITCHGEAR PART 1 - GENERAL 1.01 SECTION INCLUDES: A. Individually mounted rear-accessible low voltage switchgear ANSI rated switchgear and low voltage power circuit breakers

More information

Excel 15 W7760A BUILDING MANAGER

Excel 15 W7760A BUILDING MANAGER Excel W0A BUILNG INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The Excel W0A Building Manager is a freely configurable controller that can be used to monitor and control H equipment and other miscellaneous

More information

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI

More information

For Conduit Inspections

For Conduit Inspections Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit

More information

SECTION LAUNDRY WASHER-EXTRACTOR, 100 LB. (45.4 KG) CAPACITY

SECTION LAUNDRY WASHER-EXTRACTOR, 100 LB. (45.4 KG) CAPACITY SECTION 11110 LAUNDRY WASHER-EXTRACTOR, 100 LB. (45.4 KG) CAPACITY PART 1 GENERAL 1.01 SECTION INCLUDES: A. Automatic laundry washer-extractor for processing water-washed linen items 1.02 SYSTEM DESCRIPTION

More information

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This

More information

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference 2010 / PM CM 21st Annual Conference The High-Velocity Edge: Achieving Operational Excellence ELECTRICAL / PM CM 2010 Conference Basic Electrical Rick Miller, PE, LEED AP RNM Engineering, Inc. Vanir Corp.

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor

More information

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION Roseville Electric SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION REVISED 10/03/17 Specifications for Residential Construction Revision List REVISION Date Page No. Description 8/18/09 T.O.C., 8.1-8.1.5 &

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

Definitions. Scope. Customer Generation Interconnection Requirements

Definitions. Scope. Customer Generation Interconnection Requirements Updated 02/1 Page 1 Scope The purpose of this document is to describe Idaho Power s requirements for the installation and testing of Customer Generation acilities that are interconnected with Idaho Power

More information

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION Roseville Electric SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION REVISED 04/25/18 Specifications for Residential Construction Revision List REVISION Date Page No. Description 03/20/00 6.1-6.2 Added Armorcast

More information

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems www.switchgearpower.com Generator Controls, Paralleling Switchgear, LV Switchboards States Mfg. www.statesmfg.com Transformers (Substation

More information

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS 1. General Metering Requirements a. Interpretation The District s metering requirements shall not be interpreted to conflict with the

More information

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP Item :A Prep Room NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG-200830-C-PREP Booth Working Dimensions: 20'0 Wide x 8'0 High x 30'0 Working Depth Approx. Booth Overall Dimensions: 20'4 Wide x 8'10

More information

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial

More information

ACH 400 with Electronic Bypass

ACH 400 with Electronic Bypass ACH 400 Users Manual ACH 400 with Electronic Bypass ACH 400 with Electronic Bypass User s Manual ACH400-US-08EB 3AUA489002B4233 R0101 Rev. D EFFECTIVE: 4/20/01 SUPERSEDES: 5/15/00 2001 ABB Inc. All Rights

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Switchgear Skid, C1192

Switchgear Skid, C1192 CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

COMPACT BUSWAY 40 & 60 AMP HOUSING

COMPACT BUSWAY 40 & 60 AMP HOUSING 40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

7 Single Family Service

7 Single Family Service 7 Single Family Service 7. General The location of the service entrance on the Customer s premises is an important consideration. For clearance and location information see section 5 (Clearances). Consult

More information

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Retain for future use. 30072-450-47A July 2002 Raleigh, NC, USA HAZARDOUS VOLTAGE Read and understand

More information

ABB drives for HVAC applications ACH550, 1 to 550 Hp

ABB drives for HVAC applications ACH550, 1 to 550 Hp ABB drives for HVAC applications ACH550, 1 to 550 Hp Facility Managers Say... As the U.S. HVAC Market Leader and the world s largest manufacturer of Adjustable Frequency Drives, I know that ABB will be

More information

SECTION DISTRIBUTION AND GROUNDING

SECTION DISTRIBUTION AND GROUNDING SECTION 16400 DISTRIBUTION AND GROUNDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Furnishing and installation of a complete electrical distribution and grounding system. B. Furnish and install motor control

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-338 /0 INSTALLATION INSTRUCTIONS Original Issue Date: /0 Model: Transfer Switches with Programmable Controllers Market: ATS Subject: Transformer Kits GM6369 (480 V) and GM6859 (600 V) Introduction A

More information

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. Supersedes: 160.80-PW4 (1099) Form: 160.80-PW4 (215) FIELD CONNECTIONS ROTARY SCREW CHILLER WITH GRAPHIC CONTROL CENTER AND YORK MOD

More information

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit Instruction Sheet 10 2004 Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit 541 0810 GENERAL INFORMATION This kit contains one Control Communications Module (CCM-G) with

More information

TMS Series MP46x Flex Probes* Installation Instructions

TMS Series MP46x Flex Probes* Installation Instructions PNEUMERCATOR Liquid Level Control Systems TMS Series MP46x Flex Probes* Installation Instructions Model MP461, MP462 And MP463 Magnetostrictive Flex Probes Installation For: MODEL TMS2000 and MODEL TMS3000

More information

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual Instruction Bulletin VD0C06N908C July 1998 Raleigh, NC, USA ALTIVAR 66, ALTIVAR 58, ALTIVAR 18 Dynamic Braking Resistor Kit User s Manual DANGER HAZARDOUS VOLTAGE Read and understand this bulletin in its

More information

User s Manual. ACS550-PC/PD Packaged Drive with Disconnect Supplement to ACS550-01/U1 User s Manual

User s Manual. ACS550-PC/PD Packaged Drive with Disconnect Supplement to ACS550-01/U1 User s Manual User s Manual ACS550-PC/PD Packaged Drive with Disconnect Supplement to ACS550-01/U1 User s Manual ii ACS550-PC/PD Packaged Drive with Disconnect ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 User's

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS (Disconnect and Bypass Packages are available on Pages 56 and 57) Two Year Warranty* *When Gerrie commissions the drive Features: UL/cUL/CSA Approved

More information

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.

More information

MP461SC Flex Probes* Installation Instructions

MP461SC Flex Probes* Installation Instructions PNEUMERCATOR Liquid Level Control Systems MP461SC Flex Probes* Installation Instructions Model MP461SC Magnetostrictive Flex Probes For use with the following consoles: TMS2000 TMS3000 NOTE: MP461SC PROBES

More information

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan. 57 574 4 574 573 57 57 57 57 1 571 47 474 4 474 473 47 47 47 47 1 471 56 567 7 565 565 37 374 74 374 7 373 37 37 37 37 1 371 467 6 467 465 465 7 74 4 74 73 7 7 7 7 7 71 71 36 367 7 365 365 6 67 7 65 65

More information

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element Fusing Equipment Kearney Fuse Links Electrical Apparatus 327-40 general Cooper Power Systems Kearney fuse links can be applied to a variety of applications requiring overcurrent protection of distribution

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

TPE N-A-F-A-GQQE

TPE N-A-F-A-GQQE GRUNDFOS DATA BOOKLET TPE2 1-15-N-A-F-A-GQQE Grundfos Pump 98416973 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpe/98416973/tpe2-1-15-n-a-f-a-gqqe.html

More information

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Instruction Manual. Q Series 2 Motor Control Modules - OEM A382-21-880 Issue B Instruction Manual Q Series 2 Motor Control Modules - OEM Pump/ Q Motor Control Module Item Number pumping system Electrical supply 24 V d.c. control 24 V a.c. control QDP40 200-230

More information

Service Requirements

Service Requirements Service Requirements General Contact Idaho Power before beginning work on any new service. All meter installations must meet current electrical code requirements and display the proper electrical permit.

More information

Commercial Electric Policy

Commercial Electric Policy Commercial Electric Policy 7/19/16 1 Table of Contents General Information..3 Construction.3 Ownership.4 Multi-Unit/Multi-Service Buildings....4 Secondary Termination Enclosures.4 Meter Bases.5 Temporary

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW Medium Voltage Product Overview MVB SERIES, MEDIUM VOLTAGE DRAW-OUT CIRCUIT BREAKER MVB SERIES Standard Breaker Features : 1200, 2000, 3000 Amps, 3 phase, 60

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

Delta Products VFD CP2000 Bypass Control Packages.

Delta Products VFD CP2000 Bypass Control Packages. Delta Products VFD CP2000 Bypass Control Packages www.deltaww.com Delta Products VFD CP2000 Bypass Control Packages The Delta Products VFD CP2000 Bypass Control Packages are designed for the Delta Products

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information