IRRIGATION RENOVATION PROJECT Construction Documents

Size: px
Start display at page:

Download "IRRIGATION RENOVATION PROJECT Construction Documents"

Transcription

1 P TOUCHET VALLEY GOLF COURSE AND FAIRGROUNDS Dayton, Washington IRRIGATION RENOVATION PROJECT Construction Documents NOVEMBER 2015 Sheet Layout COVER IR0.1 PROJECT SUMMARY IR1.0 GOLF IRRIGATION PLAN IR2.0 FAIRGROUNDS/CLUBHOUSE IRRIGATION PLAN E1.0 ELECTRICAL PLAN D1.0 IRRIGATION DETAILS D1.1 IRRIGATION DETAILS D2.0 PUMP STATION LAYOUTS D2.1 VERTICAL TURBINE PUMP STATION DETAILS D2.2 CENTRIFUGAL PUMP STATION DETAILS Vicinity MapNTS Dayton, WA Site MapNTS GOLF COURSE Irrigation Consultant Greg Baer, PLA, CGIA Baer Design Group, LLC 99 E. State Street, Suite 203 Eagle, Idaho 3616 ph. (20) e. Owner Andrew Woods, PE/Director of Public Works 415 N. Guernsey Ave. Dayton, Washington 9932 ph. (509) e FAIRGROUNDS AND CLUBHOUSE

2 P IRRIGATION LEGEND BID ADD ALTERNATE #2 & #3 STA BID ADD ALTERNATE #2 & #3 BASE BID BID ADD ALTERNATE #2 & #3 BID ADD ALTERNATE #1 BID ADD ALTERNATE #2 & #3 GENERAL NOTES BASE BID BID ADD ALTERNATE #1 BID ADD ALTERNATE #1 Irrigation Summary BIDDING NOTES: BIDDING SUMMARY: NORTH Scale 1" = 100'-0" 300 IR0.1

3 IRRIGATION LEGEND Washington STA GENERAL NOTES Dayton Irrigation Plan NORTH IRRIGATION KEYNOTES Scale 1" = 100'-0" 300 IR1.0

4 IRRIGATION LEGEND STA Scale 1" = 40'-0" NORTH 120 IR2.0 Fairgrounds & Clubhouse Irrigation Plan

5 ELECTRICAL LEGEND 6 ELECTRICAL KEYNOTES Scale 1" = 100'-0" NORTH 300 E1.0 Electrical Plan

6 GEAR DRIVE ROTOR 1 VIH ROTOR 2 3 POP-UP SPRAY HEAD 4 QUICK COUPLING VALVE 5 REMOTE CONTROL VALVE ASSEMBLY 6 MAINLINE GATE VALVE 7 LATERAL ISOLATION VALVE AIR RELEASE VALVE DISTANCE CHART INSTALLATION CHART LATERAL TRENCH SECTION Irrigation Details MAINLINE TRENCH SECTION 9 Joint Restraint Chart Detail 12 Grounding 10 FIELD SATELLITE 12 TRENCH SECTION D1.0

7 CONCRETE CUT AND PATCH 1 ASPHALT CUT AND PATCH 2 3 RCV (MP ROTATOR ZONES ONLY) D1.1 Irrigation Details

8 1 PUMP STATION AT CLUB HOUSE 2 PUMP STATION AT POND P D2.0 Pump Station Layouts

9 PRESSURE TRANSDUCER FILTER SHOWN REMOVED FOR CLARITY PERFORMANCE: MINIMUM POWER: DUTY PUMP: JOCKEY PUMP: MODEL# DESIGN SPECIFICATIONS PSI 40 VOLT / 3 PHASE 30 ea 5 HP. MINIMUM HP. MINIMUM N2T030C S4S43INS PARTS LIST ITEM DESCRIPTION SIZE Count A stainless steel pressure transducer shall continually monitor system pressure. A 4-20 ma or 1-10v signal shall be transmitted to the VFD - the VFD shall react according to pre-programmed criteria. PROGRAMMABLE LOGIC CONTROLLER (PLC) The control panel shall include a PLC with a HMI touch screen operator interface. The operator interface shall allow the user to make adjustment to the PLC program locally, without requiring any additional equipment, such as a laptop computer. The VFD control keypad is not an acceptable substitution for the digital operator interface. INTEGRATED PUMP STATION ENCLOSURE 69.0" PLAN VIEW 42" NEC PANEL CLEARANCE 97.0" 76.0" FLOOR DRAIN & FLOAT SWITCH ACCESS ACCESS HATCH 60" WET WELL COVER " PVC WELL SEAL " 160# PVC.1" SLOTS " PVC PLUG PPS0 PUMP PROTECTION SLEEVE REQUIRED ON SUBMERSIBLE PUMPS TO PROVIDE MOTOR COOLING & PROTECT PUMP FROM DEBRIS - SCREENS TO BE REMOVED FROM PUMP SUCTION AR IC BFV I2GL BFV I6GL BFV IWL CHK P2S CHK P6S CHK PE HIGH PRESSURE RELIEF VALVE ASSEMBLY AIR RELIEF VALVE 3/4" 1 BUTTERFLY VALVE, LO, GV 2" 1 BUTTERFLY VALVE, LO, GV 2 BUTTERFLY VALVE, LO " 2 CHECK VALVE, SILENT 2" 1 CHECK VALVE, SILENT 2 CHECK VALVE, ENBEE " 1 EP ELECTRICAL PANEL 60X36X16 1 FM I6F FTR AS4 HP SW HPR I2FA PG 100 FLOW METER 1 FILTER, SAF 4500 " 1 HIGH PRESSURE SWITCH 1/4" 1 HP RELIEF VALVE, ANGLED 2" 1 PRESSURE GAUGE 100 PSI 2 PMP1 PUMP, TURBINE 30 HP 2 PMP2 PUMP, SUBMERSIBLE 5 HP 1 PR ST PRESSURE SENSOR 1/4" 1 SKD SKID 96X96 1 The PLC shall be fully programmed prior to pump panel installation. The technician installing and programming the PLC is to be factory trained and certified by the PLC manufacturer. The PLC and operator interface shall provide (at a minimum) the following functions: Display run status of all pumps Display systems pressure Display any fault condition and log fault with time and date stamp Display motor run hours- user re-settable Pre-programmed start-up routines for initial start-up, mainline fill, power outages, and re-start after a system fault Allow user to adjust operating variables and timing functions such as low pressure, high pressure, low water, start-up pressure and ramp time, and restart delays VFD bypass routine to allow emergency pressure differential operation of pumps if the VFD fails-user selectable Control of automatic valve supplying intake screen system Display of options such as flow and total flow HMI can be password protected to prevent unauthorized access DISCONNECT SWITCH A disconnect switch shall be integrated into the pump control panel and shall be the disconnect means for the equipment. OVERCURRENT PROTECTION The VFD bridge rectifiers shall be protected from over current by appropriately sized circuit breakers. Fuses are not acceptable. THERMAL OVERLOAD In case of VFD failure, the pump control panel shall include a magnetic starter, which consists of a contactor, circuit breaker, and thermal overload, so that the motor may be operated across-the-line manually until the VFD is repaired or replaced. VOLTAGE & PHASE MONITORING The Pump Control Panel shall monitor incoming power and automatically disconnects power if it does not meet specified criteria. A magnetic contactor will disconnect the VFD. The system shall have an automatic re-start routine when the power returns to normal. LIGHTNING AND SURGE PROTECTION The Pump Control Panel shall be equipped with transient voltage and surge arrestors. PRE-PROGRAMMED START-UP ROUTINES FRONT VIEW (PUMPS REMOVED FOR CLARITY) DUTY PUMP ASSEMBLY (X2) PRESSURE SUSTAINING PUMP ASSEMBLY 12" PLATE 10" HOLE IN SKID The PLC shall be programmed with various start-up routines that limit and/or delay, the starting, and acceleration of the pump to ensure that excessive velocity and pressure do not damage thedistribution system. The program shall include individual routines for initial start-up, mainline fill, re-start after a power outage, and re-start after a system fault. The operator shall be able to adjust the timing of the routines via the operator interface. AUTOMATIC SUCTION SCANNER FILTER QUALITY CONTROL The entire pump station and the control panel shall be designed, assembled, programmed and tested by a single manufacturer, within the confines of a UL certified manufacturing facility. The manufacturer shall employ service personnel who are trained, and certified, in every aspect of service that may be required on the pump station. It shall not be acceptable for the control panel to be designed, manufactured, programmed, or serviced by any entity, other than the pump station manufacturer. Pump Station Skid Base & Enclosure The pump skid and appurtenances shall be cleaned to bare steel and coated with a baked on powder coating. The pump station shall be pressure tested prior to coating. No welding shall be performed after the pump station is powder coated. The pump station enclosure shall be constructed of marine grade aluminum modular panels to allow access to all pumps and components by simply removing any panel. The entire front of the enclosure shall consist of hinged doors. The enclosure shall be powder coated. The roof of the enclosure shall be easily displaced and replaced by one person, for the purpose of servicing the pump station, when necessary. VENTILATION FAN The system shall include a ventilation fan (or fans) that will adequately cool all of the enclosed equipment during extreme expected seasonal temperatures. QUALIFICATIONS The VFD pump control system shall be manufactured and installed by factory trained and certified technicians with a minimum of five years experience with similar installations. The pump station manufacturer shall employ certified service technicians that are fully trained in all aspects of service on the pump station, including the VFD/PLC control system. It shall not be acceptable for it to be necessary to contact any entity, other than the pump station manufacturer, for any aspect of pump station service, or technical support. The pump control panel shall be manufactured by Precision Pumping Systems. Requests for substitutions must be submitted, in writing, to the engineer prior to the bid date. PUMP CONTROL SYSTEM The UL listed control panel shall include variable frequency drives (VFD), and programmable logic controllers (PLC). The VFD pump control panel shall be manufactured and listed by a UL50 Panel Shop The panel shall be UL labeled as an "Enclosed Industrial Control Panel". The pump control panel shall be completely manufactured, tested and programmed prior to delivery to the job site. A wiring schematic and pump(s) nameplate information shall be permanently affixed to the inside of the control enclosure. The VFD and associated electrical equipment shall be mounted in a UL Type 3R enclosure for outdoor installation, or UL type 12 enclosure for indoor installation. The cooling system shall prevent the VFD from reaching high ambient temperatures, which will cause temperature faults or warnings. The cooling system shall not allow dust and/or dirt inside the pump control panel. The filter shall be an Amiad SAF automatic suction scanner type filter with electric motor and electronic control. Hydraulic motors shall not be accepted. The filter shall have a removable cylindrical four-layer filtration element made entirely of Type 316L stainless steel weave-wire screen. The installed filter shall be as indicated on the drawing, and shall be rated for the full flow of the pump station. COOLING & VENTILATION The pump station enclosure shall be completely insulated. The insualtion material shall have a minimum R-Value of 13. The pump station shall include an integrated air conditioning system to ensure that no equipment shall fault or be damaged during expected extreme seasonal temperatures. VARIABLE FREQUENCY DRIVES (VFD) The VFDs shall be appropriately sized to meet the FLA, full load amps, required by the pump motor as stated on the motor nameplate. Initial start-up and calibration shall be performed by a Precision Pumping Systems factory certified technician, which shall extend the warranty on the control panel from one year to two years. With a three year available. VFD ALTERNATION If the pump station is equipped with multiple pumps, the pump control system shall automatically alternate VFD control between the lead and lag pumps, in multiple lead / lag pump configurations. This function shall equalize usage of all of the pumps in the system. this function is critical to ensure that the lead / lag configuration functions properly, and efficiently over the long term. JOCKEY PUMP The system shall include a jockey pump. The jockey pump shall be variable speed, and shall be controlled by a separate VFD. Vertical Turbine Pump Station Details D2.1

10 TOP VIEW FILTER FLUSH LINE CW SCREEN LINE ELECTRICAL CONDUIT 66.0" RECOMMENDED CONCRETE PAD LAYOUT PROVIDED BY OTHERS (SHOWN WITH PUMP STATION) Ø4.0" 63.0" 93.0" RECOMMENDED CONCRETE PAD LAYOUT PROVIDED BY OTHERS (SHOWN WITHOUT PUMP STATION) 30.0" 36.0" 30.0" 4.0" 4" HOLE WITH CAP & 1/2" COUPLER ON TOP (FLOOR DRAIN & FLOAT SWITCH ACCESS) 66.0" DUTY PUMP/VAF FILTER ASSEMBLY PRECISION PUMPING SYSTEMS ENCLOSED PUMPING STATION MODEL: V1C015X V32X243ONS PERFORMANCE: PSI MAIN PUMP: 10 hp. MINIMUM TYPE: END-SUCTION CENTRIFUGAL POWER: 240-VOLT / 1-PHASE / 60-HZ 57.0" Part List ITEM DESCRIPTION SIZE Count AR IC BFV I2GL BFV I3GL CHK P2S CHK P3S AIR RELIEF VALVE 3/4" 1 BUTTERFLY VALVE, LO, GV 2" 1 BUTTERFLY VALVE, LO, GV 3" 2 CHECK VALVE, SILENT 2" 1 CHECK VALVE, SILENT 3" 1 CW VL CW CONTROL VALVE 1 EP ELECTRICAL PANEL (SIZE) 1 PMP PUMP, CENTRIFUGAL 5HP 1 SKD SKID 66X4 1 VAF 3 VAF FILTER 3" 1 PROGRAMMABLE LOGIC CONTROLLER (PLC) The control panel shall include a PLC with ahmi touch screen operator interface. The operator interface shall allow the user to make adjustment to the PLC program locally, without requiring any additional equipment, such as a laptop computer. The VFD control keypad is not an acceptable substitution for the digital operator interface. The PLC shall be fully programmed prior to pump panel installation. The technician installing and programming the PLC is to be factory trained and certified by the PLC manufacturer. The PLC and operator interface shall provide (at a minimum) the following functions: Display run status of all pumps Display systems pressure with password protected set point control Display any fault condition and log fault with time and date stamp Display motor run hours- user re-settable Pre-programmed start-up routines for initial start-up, mainline fill, power outages, and re-start after a system fault Allow user to adjust operating variables and timing functions such as low pressure, high pressure, low water, start-up pressure and ramp time, and restart delays VFD bypass routine to allow emergency pressure differential operation of pumps if the VFD fails-user selectable Control of automatic valve supplying intake screen system Display of options such as flow and total flow VFD ALTERNATION The pump station is equipped with multiple pumps, the pump control system shall automatically alternate VFD control between the lead and lag pumps, in multiple lead / lag pump configurations. This function shall equalize usage of all of the pumps in the system. this function is critical to ensure that the lead / lag configuration functions properly, and efficiently over the long term. DISCONNECT SWITCH A circuit breaker disconnect switch shall be integrated into the pump control panel and shall be the disconnect means for the equipment. OVERCURRENT PROTECTION The VFD bridge rectifiers shall be protected from over current by appropriately sized circuit breakers. Fuses are not acceptable. THERMAL OVERLOAD In case of VFD failure, the pump control panel shall include a magnetic starter, which consists of a contactor, circuit breaker, and thermal overload, so that the motor may be operated across-the-line manually until the VFD is repaired or replaced. VOLTAGE & PHASE MONITORING QUALITY CONTROL The entire pump station and the control panel shall be designed, assembled, programmed and tested by a single manufacturer, within the confines of a UL certified manufacturing facility. The manufacturer shall employ service personnel who are trained, and certified, in every aspect of service that may be required on the pump station. It shall not be acceptable for the control panel to be designed, manufactured, programmed, or serviced by any entity, other than the pump station manufacturer. PUMP STATION SKID BASE & ENCLOSURE The pump skid and appurtenances shall be cleaned to bare steel and coated with a baked on powder coating. The pump station shall be pressure tested prior to coating. No welding shall be performed after the pump station is powder coated. The pump station enclosure shall be constructed of marine grade aluminum modular panels to allow access to all pumps and components by simply removing any panel. The entire front of the enclosure shall consist of hinged doors. The enclosure shall be powder coated. The roof of the enclosure shall be easily displaced and replaced by one person, for the purpose of servicing the pump station, when necessary. VENTILATION FAN The system shall include a ventilation fan (or fans) that will adequately cool all of the enclosed equipment during extreme expected seasonal temperatures. QUALIFICATIONS The VFD pump control system shall be manufactured and installed by factory trained and certified technicians with a minimum of five years experience with similar installations. The pump station manufacturer shall employ certified service technicians that are fully trained in all aspects of service on the pump station, including the VFD/PLC control system. It shall not be acceptable for it to be necessary to contact any entity, other than the pump station manufacturer, for any aspect of pump station service, or technical support. The pump control panel shall be manufactured by Precision Pumping Systems. Requests for substitutions must be submitted, in writing, to the engineer prior to the bid date. PUMP CONTROL SYSTEM The UL listed control panel shall include variable frequency drives (VFD), and programmable logic controllers (PLC). The VFD pump control panel shall be manufactured and listed by a UL50 Panel Shop The panel shall be UL labeled as an "Enclosed Industrial Control Panel". The pump control panel shall be completely manufactured, tested and programmed prior to delivery to the job site. A wiring schematic and pump(s) nameplate information shall be permanently affixed to the inside of the control enclosure. The VFD and associated electrical equipment shall be mounted in a UL Type 3R enclosure for outdoor installation, or UL type 12 enclosure for indoor installation. The cooling system shall prevent the VFD from reaching high ambient temperatures, which will cause temperature faults or warnings. The cooling system shall not allow dust and/or dirt inside the pump control panel. VARIABLE FREQUENCY DRIVES (VFD) The VFDs shall be appropriately sized to meet the FLA, full load amps, required by the pump motor as stated on the motor nameplate. The VFD shall be an ABB ACS series, manufactured by ABB Industrial Systems, Inc. or Mitsubishi F700 series, manufactured by Mitsubishi electric. Initial start-up and calibration shall be performed by a Precision Pumping Systems factory certified technician, which shall extend the warranty on the control panel from one year to two years. With a three year available. PRESSURE TRANSDUCER A stainless steel pressure transducer shall continually monitor system pressure. A 4-20 ma or 1-10v signal shall be transmitted to the VFD - the VFD shall react according to pre-programmed criteria. The Pump Control Panel shall monitor incoming power and automatically disconnects power if it does not meet specified criteria. A magnetic contactor will disconnect the VFD. The system shall have an automatic re-start routine when the power returns to normal. LIGHTNING AND SURGE PROTECTION The Pump Control Panel shall be equipped with transient voltage and surge arrestors. PRE-PROGRAMMED START-UP ROUTINES The PLC shall be programmed with various start-up routines that limit and/or delay, the starting, and acceleration of the pump to ensure that excessive velocity and pressure do not damage the distribution system. The program shall include individual routines for initial start-up, mainline fill, re-start after a power outage, and re-start after a system fault. The operator shall be able to adjust the timing of the routines via the operator interface. HIGH DISCHARGE PRESSURE SWITCH The pump system shall be equipped with a high-pressure switch. AUTOMATIC SUCTION SCANNER FILTER The filter shall be an VAF automatic suction scanner type Hydraulic motors shall not be accepted. The filter shall have a removable cylindrical four-layer filtration element made entirely of Type 316L stainless steel weave-wire screen. The installed filter shall be as indicated on the drawing, and shall be rated for the full flow of the pump station. Centrifugal Pump Station Details JOCKEY PUMP The system shall include a jockey pump. The jockey pump shall be variable speed, and shall be controlled by a separate VFD. D2.2

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

CITY OF WEST PALM BEACH

CITY OF WEST PALM BEACH REVISION: OCT. 2018 SUBMERSIBLE LIFT STATION - WET WELL SECTION VIEW SLS-2 WETWELL DATA PUMP/ELECTRICAL DATA REVISION: OCT. 2018 SUBMERSIBLE LIFT STATION - REQUIRED DATA SLS-3 PUMP TEST / START-UP FORM

More information

Lift Station Design Standards and Details. Summary of Revisions

Lift Station Design Standards and Details. Summary of Revisions Lift Station Design Standards and Details Summary of Revisions April 2017 Updates Standard Detail SLS 19 SUBMERSIBLE LIFT STATION GROUDING PLAN & S Removed Barbed Wire from FENCE GROUNDING. TYPICAL LIFT

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Variable Speed Product Line

Variable Speed Product Line Variable Speed Product Line BRCPVFD R1 Variable Speed Product Line Since 1997, CentriPro has been providing variable speed pump control solutions to its customers. The first product was the Aquavar variable

More information

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems. Issued 2005/06/01 Section 15440 Plumbing Pumps Page 1 of 9 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780 Closeout

More information

TW1000E-20W-70-DCA In Enclosure w/ Double Check Assembly VARIABLE SPEED BOOSTER SYSTEM

TW1000E-20W-70-DCA In Enclosure w/ Double Check Assembly VARIABLE SPEED BOOSTER SYSTEM TW1000E-20W-70-DCA In Enclosure w/ Double Check Assembly VARIABLE SPEED BOOSTER SYSTEM Revised 7/28/16 The TW1000E-20W-70-DCA booster system is equipped with a Stainless Steel centrifugal pump and regulated

More information

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

TW G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

TW G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM TW1000-75G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM The TW1000-75G-40 Flag Frame Booster System is equipped with a centrifugal pump regulated by a variable frequency drive that controls the pump

More information

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life ITT BRSDRIVE Goulds Pumps Simplex Variable Speed Submersible Pump Controller C U L US Engineered for life Do you want to Simplify your Commercial Pumping System? Goulds Pumps S-Drive variable speed, constant

More information

PUMPS AND FILTRATION

PUMPS AND FILTRATION Rain Bird applies its industry leading irrigation expertise to the design and manufacture of pump stations and filtration products. By doing so, Rain Bird is the only irrigation manufacturer able to provide

More information

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK PART 1 - GENERAL 1.1 GENERAL: SECTION 15150 MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK A. The Mechanical Contractor shall furnish to the Electrical Contractor for installation,

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

Air Handling Unit Construction Checklist

Air Handling Unit Construction Checklist Air Handling Unit Construction Checklist Project: Date: AHU Tag: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing.

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 262913 - ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM 1.0 GENERAL 1.1 DESCRIPTION A. Manufacturer shall furnish an aeration system capable of providing more equal distribution of oxygenated water throughout

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2 SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2 SPD Plus Do you want to simplify your commercial pumping system and save energy? CentriPro SPD Plus variable speed, constant

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

SECTION VARIABLE FREQUENCY DRIVE UNITS

SECTION VARIABLE FREQUENCY DRIVE UNITS SECTION 26 29 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide variable frequency drive (VFD) units, complete and operable, in accordance with the Contract Documents. It

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM TW1000-20W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM TW1000-20W-40 FLAG FRAME The TW1000-20W-40 Flag Frame Booster System is equipped with a centrifugal pump regulated by a variable frequency drive that

More information

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting

More information

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter. General Model MS150-4-150 expandable/modular central vacuum system consisting of 4 Becker or approved equivalent KVX3.140-400 vacuum pumps mounted on a common skid with expandable automatic alternating

More information

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS TECHNICAL BROCHURE BSPDDRIVE C U L US Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS Aquavar SPD variable speed, constant pressure pump controller

More information

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM TW1000-20W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM TW1000-20W-40 FLAG FRAME The TW1000-20W-40 Flag Frame Booster System is equipped with a centrifugal pump regulated by a variable frequency drive

More information

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION Specification Number: 26 24 13.20 Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION 26 24 13.20 SWITCHBOARDS (Long) Main Disconnect Group Mounted Fusible

More information

Hydrovar and Packaged Hydrovar

Hydrovar and Packaged Hydrovar Hydrovar and Packaged Hydrovar MOTOR MOUNT VARIABLE SPEED PUMP CONTROLLER AND INTEGRATED PUMP PACKAGES BRHYDROVAR R3 Goulds Water Technology Hydrovar and Packaged Hydrovar Hydrovar Variable Speed Drives

More information

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS TECHNICAL BROCHURE BAQUAeABII * Available up to 1 GPM systems Aquavar e-abii VARIABLE SPEED CONSTANT PRESSURE SYSTEMS 1 HP thru 5 HP - Pressure Booster Packages 1AB2 and 2AB2 Prewired Pump/Controller Kits

More information

Pumps and Filtration

Pumps and Filtration Rain Bird applies its industry leading irrigation expertise to the design and manufacture of pump stations and filters to provide solutions to meet customer requirements. By doing so, Rain Bird is the

More information

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical New A Secondary Chill / 60V /36A Fused Disconnect For A Secondary Chill and Flex New B Secondary Chill / 60V / 36A B Secondary Chill Single 2.5 Conduit. Install New Additional 2.5 R.S.G. Conduit From 00A

More information

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Related Sections: 1. Section 15050 - Basic Mechanical Requirements. 2. Section 15051 - Motors. 3. Section 15185 - Hydronic Pumps. 4. Section 15625 - Centrifugal

More information

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD Safety Precautions Read this manual thoroughly before proceeding with installation, connections (wiring), or maintenance and inspection. Ensure you

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

team master medium voltage solid state starters

team master medium voltage solid state starters team master medium voltage solid state starters The Today s global economy is in many ways driven by the AC Induction Motor. Industrial facilities worldwide depend on these motors to drive the machinery

More information

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING AUGUST, 2004 REV.A CURTIS TOLEDO OPERATOR S MANUAL SUPPLEMENT AF Series Compressors VS models with VFD WARNING Personal injury and/or equipment damage will result by failing to pay attention to the vital

More information

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide

More information

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller ITT BSPDDRIVE Goulds Pumps Aquavar SPD (Single Pump Drive) C U L US Do you want to Simplify your Commercial Pumping System? Goulds Pumps SPD variable speed, constant pressure pump controller is designed

More information

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS APPENDIX A 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS The Technology Center of DuPage is seeking bids for fifteen (15) dual weld stations (total of 30 individual welding booths) with fume

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM 1.0 GENERAL 1.1 DESCRIPTION A. Manufacturer shall furnish an aspirating directional aerator (aspirator) or a high-flow directional aerator

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications AIR-COOLED, OIL-FREE AIR COMPRESSOR Frame 0, 1, 2 50 500 HP ROGERS 2110_KA.doc Effective: 03-24-17 Supersedes: 04-06-15 Page 1 of 9 1. SPECIFICATIONS SCOPE 1.1

More information

SECTION MOTOR CONTROLLERS

SECTION MOTOR CONTROLLERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Softstarters. Softstarters Type SSM Medium voltage ,800V 1 Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum

More information

PATTERSON PUMP COMPANY

PATTERSON PUMP COMPANY PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013 Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL

More information

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump. General 1 Model MS 9-2-60 expandable/modular duplex central vacuum system consisting of two Becker or approved equivalent VT4.25 vacuum pumps mounted on a common skid with expandable automatic alternating

More information

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan. 57 574 4 574 573 57 57 57 57 1 571 47 474 4 474 473 47 47 47 47 1 471 56 567 7 565 565 37 374 74 374 7 373 37 37 37 37 1 371 467 6 467 465 465 7 74 4 74 73 7 7 7 7 7 71 71 36 367 7 365 365 6 67 7 65 65

More information

Climas y Proyectos Leyco, S.A. de C.V.

Climas y Proyectos Leyco, S.A. de C.V. GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA

More information

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD CONTROL PANEL MOUNTING PAGE No. 74 NUMBER: LS-240V1PH-TCU-VFD 35 38 47 U A 9 33 V 26 24 25 41 43 7 7 44 ALUMINUM BACKPLATE 41 42 50 46

More information

AQUAVAR AQUAVAR 56 AQUAVAR CPC

AQUAVAR AQUAVAR 56 AQUAVAR CPC AQUAVAR AQUAVAR 56 AQUAVAR CPC Variable Speed Controllers www.goulds.com Goulds Pumps ITT Industries AQUAVAR Pump Control Systems Contents Control Systems Overview... 2 Standard AQUAVAR Controllers, 2

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER 1 & 3 Phase, 50/60Z, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload

More information

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST Date Documents Submitted: Log No.: File No.: Plan Examiner: Permit No.: Property Information Building Name: Building Address: Building Manager's Name: Building Manager's Phone: Fax: System Designer/Contractor

More information

Smart controls Reliable operation User friendly design Plug and play operation

Smart controls Reliable operation User friendly design Plug and play operation Series H2-ID1 RAINSETS Series H2-ID1 Rainsets manage the distribution and water treatment functions of commercial rainwater system installations. The modular H2-ID1 series is designed for indoor installations

More information

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter. 1 General Model MS100-3-60 expandable/modular duplex central vacuum system consisting of two Becker or approved equivalent KVX 3.140/1-400 vacuum pumps mounted on a common skid with expandable automatic

More information

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications. Goulds Pumps AquaForce PRESSURE BOOSTING SIZING GUIDE Building and Municipal Applications Goulds Pumps is a brand of ITT Corporation. www.goulds.com Engineered for life AquaForce GENERAL INFORMATION The

More information

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS FEATURES NEMA 3R Enclosure: Rainproof, outdoor/ indoor rated enclosure. Current

More information

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump. 1 General Model MS300-4-530 expandable/modular central vacuum system consisting of 4 Becker or approved equivalent VTLF2.250 vacuum pumps mounted on a common skid with expandable automatic alternating

More information

.3 Section Waste Management and Disposal.

.3 Section Waste Management and Disposal. Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section

More information

Duplex Commercial Pressurizer -DCP

Duplex Commercial Pressurizer -DCP Duplex Commercial Pressurizer -DCP Pre-Engineered Two-Pump Booster Reliable, Efficient and Easy Thrush Duplex Commercial Pressurizer Thrush Duplex Commercial Pressurizers are pre-engineered pressure booster

More information

VARIABLE FREQUENCY DRIVES

VARIABLE FREQUENCY DRIVES 262923 VARIABLE FREQUENCY DRIVES PART 1: GENERAL 1.01 SUMMARY A. Section Includes: 1. Variable Frequency Drives (VFD) B. Related Sections: 1. Section 230000 - Basic HVAC Requirements 2. Section 230900

More information

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D IS O 9 0 0 1 IT Y S Y S T E M R LISTED RBA N K S MOR S E P U MP C F AI LISTED UAL T IF IE D R CE R Q FIRE PUMPS HORIZONTAL SPLIT CASE FIRE PUMP SYSTEM DIESEL ENGINE DRIVEN 1 4 5 2 3 6 7 8 1. Fuel Tank,

More information

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) PACKAGED PUMP SYSTEM WITH CAPACITIES TO 300GPM, PRESSURE BOOST TO 100PSI* WITH UP TO 25HP ON EACH PUMP AVAILABLE IN DUPLEX, AND TRIPLEX CONFIGURATION, AND

More information

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER TECHNICAL BROCHURE BAQUACPC Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER Introduction The Aquavar CPC (Centrifugal Pump Controller) from incorporates the latest state-of-the-art Aquavar technology,

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Wilo CO-Helix Pressure Boosting Systems. Engineering Specification

Wilo CO-Helix Pressure Boosting Systems. Engineering Specification Wilo CO-Helix Pressure Boosting Systems Engineering Specification 22 PLUMBING 22 11 23.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 GENERAL 1.01 SECTION INCLUDES A. Vertical, multistage, centrifugal

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard Copyright 2008 Earthsafe Systems, Inc. This information is provided to consulting engineers and prospective customers for the purpose of specifying Earthsafe Emergency Power Fuel Systems. Reproduction

More information

Fincor Series 2230 MKII/2240

Fincor Series 2230 MKII/2240 Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new

More information

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life BRAQCPC IT T Goulds Pumps AQUAVAR CPC Variable Speed Centrifugal Pump Controller Engineered for life Goulds Pumps Variable Speed Centrifugal Pump Controller 2 Introduction The Aquavar CPC (Centrifugal

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Acceptance Inspection Date of Review / / BLD20 - Project Address: Project Name: Numbers following worksheet comments represent an NFPA

More information

Illuminator Series CR NEMA 3R

Illuminator Series CR NEMA 3R Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the

More information

Wilo Stratos Z Variable Speed, Wet Rotor Inline Pumps. Engineering Specification

Wilo Stratos Z Variable Speed, Wet Rotor Inline Pumps. Engineering Specification Wilo Stratos Z Variable Speed, Wet Rotor Inline s Engineering Specification PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install inline circulating pumps consistent with the hydronic system s performance,

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran 4 Project:_ Engineer:_ Mitsubishi Electric Automation, Inc. (MEAU) Variable Frequency Drives - HVAC System Submittal Summary Data Form NEMA 1 Bypass Systems Architect:_ Contractor:_ Submitted by: Date:

More information

Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah (801) Ph. (801) Fx.

Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah (801) Ph. (801) Fx. Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah 84047 (801) 566-5678 Ph. (801) 566-7745 Fx. New 850 kw Prime Power Natural Gas Generator Set Approval Status: Energetech s Packager is an Approved

More information

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Sola/Hevi-Duty S3K Series Mini-Tower UPS Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical

More information

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Quick guide. Plug-in fans GPPM with FC101_106 August 2014 Quick guide Plug-in fans GPPM with FC101_106 August 2014 Fläkt Woods permanent magnet motors and speed controllers for plug fans GPPM 1. General Fläkt Woods offers a wide range of permanent magnet motors

More information

STS SERIES. Enclosed Automated Fuel Maintenance Systems (STS)

STS SERIES. Enclosed Automated Fuel Maintenance Systems (STS) STS SERIES Enclosed Automated Fuel Maintenance Systems (STS) AXI s Enclosed Automated Fuel Maintenance Systems are programmable and automated self-contained, stand-alone fuel filtration, separation, and

More information

1000 Series Neptune Booster Systems. Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F

1000 Series Neptune Booster Systems. Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F 1000 Series Neptune Booster Systems Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F 140 Years of Pump Manufacturing American-Marsh Pumps, one of the oldest pump lines in America, are pump

More information

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Special Specification 6058 Battery Back-Up System for Signal Cabinets Special Specification Battery Back-Up System for Signal Cabinets 1. DESCRIPTION 2. DEFINITIONS Install a Battery Back-Up System (BBU System) for traffic signals that will provide reliable emergency power

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP Item :A Prep Room NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG-200830-C-PREP Booth Working Dimensions: 20'0 Wide x 8'0 High x 30'0 Working Depth Approx. Booth Overall Dimensions: 20'4 Wide x 8'10

More information

XT SERIES Jockey Pump Controllers Features

XT SERIES Jockey Pump Controllers Features XT SERIES Jockey Pump Controllers Features XT Series Jockey Pump Controllers March 2012 1-1 XT Power Controls The XT Series of Jockey Pump Controllers incorporate Eaton s XT Power Controls which are designed

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance

More information

Dual ground lug - one lug for earth ground, one lug for utility ground.

Dual ground lug - one lug for earth ground, one lug for utility ground. The Type 3R Package is specifically designed for Yaskawa Variable Frequency Drives. The Type 3R outdoor duty package is not just a "NEMA 3R" self-declared rating. Yaskawa went beyond its own stringent

More information

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL Centrifugal Chiller PE046, PE047, PE048, PE050 PEH046-050 PF083, PF096, PF105, PF116 PH046-050 PHH046-050 PL-906-49 Unit ASSY. - Labels / 1987 to Present Unit ASSY. - Labels / 1987 to Present No. Index

More information

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP KOBELCO KNW SERIES 1 OF 10 1. SPECIFICATIONS SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all

More information