Shimadzu's Total Solutions for the Hydrocarbon Processing Industry

Size: px
Start display at page:

Download "Shimadzu's Total Solutions for the Hydrocarbon Processing Industry"

Transcription

1 Analytical and Testing Instruments for the HPI Market Shimadzu's Total Solutions for the Hydrocarbon Processing Industry C10G-E067

2 World Map of Shimadzu Sales, Service, Manufacturing, and R&D Facilities Sales and Service Manufacturing R&D

3 Shimadzu's Total Solutions for the Hydrocarbon Processing Industry (Petrochemical, Chemical) The Hydrocarbon Processing Industry (HPI), encompassing petroleum refining, gas processing, petrochemical and chemical, is a foundational field for all industry. In the HPI market, many kinds of analytical and measuring instruments are used for quality control purposes and process management. With a wide range of products, from GC and Elemental Analyzers to an On-line Water Quality Analyzer, Shimadzu offers total support for laboratories in the HPI market. From Upstream to Downstream, our rugged, high-quality products are perfectly suited to meet the demands of your laboratory and contribute to your business success. Upstream Developing, Extracting Exploration, Finding Transporting, Storage Supply, Trading Manufacturing, Refining Downstream For more information about Shimadzu's solutions for the HPI market, visit our website at:

4 Shimadzu Customized GC Analyzers Nexis GC-2030 Product Lineup Natural Gas Analyzers Refinery Gas Analyzer (RGA) Process and Custom Gas Analyzers TOGA/DGA Analyzer Petrochemicals analyzer ASTM D1945/D1946 UOP 539, ASTM D7833, ASTM D1946 ASTM D3612C ASTM GPA 2261, GPA 2177 D 2163 ASTM E1746 D6228 Applicable Methods GPA 2286, GPA 2186 ISO 6975 Analysis C1-C6+ Hydrocarbons, Non Condensable gases O2, N2, CO, CO2 and H2S Optional Hydrogen Extended NGA C1-C14+ C1-C6+ Hydrocarbons saturates and unsaturates H2S, Non Condensable gases O2, N2, CO, CO2 and H2 O2, N2, CO, CO2 Impurities in Chlorine TOGA with Head Space H2, O2, N2, CO, CO2, C1, C2's, C3's Trace Sulfur NGL, Dual Oven NGA LPG Sampling High Speed NGA Vaporizer Analysis time 10 min. Analysis time less than Special Hastelloy High Sensitivity PFPD for Sulfur 6 min. Material for Chlorine Analyzer Extension up to C4 Various Applications in the HPI Market Transformer Oil Gas Analyzer (TOGA) Support third-party detectors, including a pulsed flame photometric detector (PFPD) and a pulsed discharge helium ionization detector (PDHID). Support third-party software for detailed hydrocarbon analysis (DHA) and Chrom Merge. Support liquefied petroleum gas (LPG) sampling devices and vaporizers. Complete application manual and methods 4

5 Trace Moisture Analysis GC System Barrier Ionization Discharge (BID) Detector High Sensitivity Detection Sensitivity over 100 x Higher than TCD, 2 x Higher than FID Novel Universal Detector Single Detector Approach for Complex Analyses Long-Term Stability Long-Term Stability with New Discharge Design Quartz tube (dielectric substances) Column He plasma uv BID 1. Easily analyzes both liquid and gas samples 2. Uses a variety of Watercol TM GC columns depending on the matrices 3. Uses a simple, high-sensitivity, and very stable low-cost GC detector LPG(Main) Water 25 ppm, RT= 14.3 min, S/N= min Note: With baseline subtraction Analysis of Water in LPG Simulated Distillation DHA Analyzers Oxygenates Analyzers Sulfur Analyzers Aromatics Analyzers ASTM D7096, D7213, D3710, D2887, D6417, D6352, D7500, D5307, D7169, IP 480, ISO3924 ASTM D5134, D6729, D6730, D6733 ASTM D4815,D7423 UOP 960 ASTM D6228 ASTM D5504 ASTM D5623 ASTM D3606, 5580 Boiling Point Distribution C1-C110 (As per method) C1-C14 Hydrocarbons PIONA Report C1-C4 Alcohols Trace Sulfur Analysis Individual components Aromatics Fast Simdist Correlations with D86 and D1160, Integrated Shimadzu Software Tuned D6730 column Fast DHA Front End PIONA Room Temperature Database Use of N2 Carrier for D4815 Use of FPD, PFPD or SCD Detectors Combination model for D3606, D5580. D4815 Simulated Distillation Analyzer C14 C16 C18 C20 C24 C26 C30 C32 C34 C36 C38 C42 C44 C46 C48 C50 C52 C54 C56 C28 C40 C68 C72 C76 C80 C84 C88 C92 C96 C100 C60 C64 C110 C12 ASTM D7500 Calibration Mix Shimadzu's Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market 5

6 Aromatics Analysis HPLC ASTM D 6591, D6379, IP 391, IP 436, IP 548, IP590 Aromatics in fuels Poly-aromatics in diesel FAME in jet fuel Mono-Aromatics Di-Aromatics Non-Aromatics Switching Valve Configuration Super Performance and Expandability Precise Sample Injection Tri-Aromatics Aromatics Ref. Std. ASTMD6591 ASTM D5837 Components in transformer oil Furan Analysis HPLC Chromatogram View mav 15.0 PDA Ch1 Absorbance (220nm+/- 4nm) (+) Max Intensity : 7,116 Time Inten Furfury alcohol/ /5.102 /7.233 /8.414 / min mav Max Intensity : 14, PDA Ch2 Absorbance (282nm+/- 4nm) (+) Time Inten hydroxymethyl-2-furaldehyde/ furaldehyde/7.233 / furaldehyde/8.414 /8.414 / hydroxymethyl-2-furaldehyde/9.388 Fully Integrated System Network Connectivity High Sensitivity Detector min Furan Chromatogram 6

7 LC / MS / MS Additives in polymers LCMS-8060 High Speed and High Sensitivity Scan Speed 30000u / sec MRM 555 Ch / Sec EPA 8270B, TO -14, IP-585 MS Chromatograms of Polymer Additives Analysis of Additives in Plastic VOCs Analysis GC-MS Volatile organic compounds Arsine phosphine in ethylene FAME in jet fuel HS-20 Headspace Analysis System GCMS-QP2020 NX Accessories HS, TD and P&T High Sensitivity and Reduced Cost High Efficiency Multicomponent Analysis TD-30 Thermal Desorption System Shimadzu's Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market 7

8 Inductively Coupled Plasma Mass Spectrometer (ICP-MS) Customized Trace elements in naphtha Determination of toxic arsenic species using LC-ICP-MS AsV AsIII DMAs AsB Arsenic Chromatogram Easy Method Development Lowest Running Costs High Stability, High Sensitivity and Low Interference Elemental Analysis ASTM D4951, D5184 ASTM D4951,D5184 UOP 389, UOP 303 UOP 714, APHA 3120, IFP 9507 All elements Lubricating oils Petroleum naphtha, gasoline Marine fuel, fuel oil, heavy oils ICP Atomic Emission Spectrometer (ICPE) Cr Cond 2 Intensity Intensity ICPE-9800 Series Cr in Naphtha with ISO Mist Kit Easy Method Development Low Argon Consumption All Wavelength Acquisition 8

9 Atomic Absorption Spectrophotometer (AAS) ASTM D6595, D3237, D3567, D3605, D3635, D3831, D3919, D4628, IFP9312, UOP946, D5863 Additives in polymers All elements Lubricating oil Petroleum oils Lead in gasoline Abs Unique 3D Double Beam Optics AA-7000 Comprehensive Safety Functions Dual Background Correction Functions Conc(NONE) Abs= Conc r= Arsenic in Vacuum Gas Oil (VGO) ASTM D5839, ASTM D4294, C114 ISO 8754 Sulfur in oil All elements Energy Dispersive X-ray Fluorescence Spectrometer (EDX) Measured Intensity (cps/ua) EDX-7000/8000/ Standard Value (ppm) High Sensitivity, High Speed and High Resolution Large Sample Chamber Easy-To-Use Operation Zn in Lubricant Oil Shimadzu's Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market 9

10 Fourier Transform Infrared Spectrophotometer (FTIR) D7371, EN 14078, D7575, D7678 Fame in biodiesel Total petroleum hydrocarbons Additives in polymers Oil in water 1.2 Abs CSD1 CSD2 CSD3 CSD4 CSD5 CSD6 CSD7 Concentration Sample Absorbance [ppm] Height CSD IRSpirit CSD CSD CSD r=1.0 CSD CSD CSD cm -1 Space Efficient with High Expandability Dedicated IR Pilot Program High Reliability Enlarged View of Peaks Around 2920 cm -1 Calibration Curve and Standard Sample Concentrations Analysis of Oil in Water ASTM D1840, D2008 Petroleum products Turbine fuels Mineral oils UV-VIS Spectrophotometer (UV-Vis) Transmittance (%) y UV Wavelength (nm) Transmittance Spectra of Colored Cellophane Tape x Chromaticity Diagram of XY Color System Analysis of Colored Cellophane Tape Easy Operation Allows Obtaining Answers Rapidly Advanced Regulatory Compliance High Performance to Meet Diverse Needs 10

11 Thermal Analyzers ASTM D3417, D3418, D4419, D4591, D5483, ASTM D3850, D6370, D6375, Thermal properties of polymers DSC, TGA, TG/DTA, TMA DSC mw 40 HDPE J/g DSC-60 Plus C C C C PP J/g J/g C C C C Blend (PE8-PP2) C mj mj High Performance DSC / TGA Diverse Measurements by Simple Operations High Sensitivity C Temp [ C] DSC Curves of HDPE, PP, and Blend Sample ASTM D5412, JPI-5S Measuring oil in water Coumarin in diesel Spectrofluorophotometer Calibration Curve Fluorescence Intensity Fluorescence Intensity RF nm Coumarin in Diesel Concentration (mg/l) High Sensitivity High Stability and High Speed High Speed 3D Scanning Fluorescence Quantum Yield and Fluorescence Quantum Efficiency Measurement Shimadzu's Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market 11

12 Total Organic Carbon (TOC) Analyzer ASTM D7573, EN 1484, EPA APHA 5310B TOC in various types of water, including high salt content water TOC-L Series 680 DegC Combustion Method High Salt Kit Standalone System TOC in Brine Solution TOC in various types of water On-line TOC Analyzer 0,35 0,3 0,25 NPOC in mg/i 0,2 0,15 0,1 0,05 0, Number of Measurements TOC Analysis in Condensate Sample Mean Value 0.208mg/L, SD 0.006mg/L, DL 0.05mg/L Superior Sampling Units Low Operation Costs Low Maintenance Costs 12

13 Testing Machines ISO 6892, ISO 527, ASTM D638 Tensile properties of metals Tensile properties of plastics PP_1 PC_1 PVC_1 70 Stress (N/mm 2 ) AG-Xplus Series Short Test Cycle Time Ultrafast Sampling Rate Eight Fold High Resolution Displacement (Strain) (%) Tensile Test of PP, PV, PVC Various petrochemicals streams Particle Size Analyzer Polystyrene Latex : 50nm, : 100nm, : 50nm + 100nm Normalized Particle Amount Particle Diameter (nm) SALD-2300 Normalized Particle Amount Particle Diameter (nm) Samples with Broad Distribution Wide Range 17nm-2500um Wide Range of Accessories High Sensitivity / High Concentration Shimadzu's Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market 13

14 Shimadzu Analytical Network Data System LabSolutions CS Controlling other vendor s GC and HPLC using LabSolutions DB/CS Client PC *2 ipad *3 Laboratory or office LabSolutions server Acquisition controller PC *1 Acquisition controller PC Shimadzu LC Shimadzu GC Shimadzu LC Shimadzu GC Agilent LC Agilent GC Agilent LC Agilent GC *1 The acquisition controller PC controls the analytical instruments. Analysis directions and re-analysis of data can be performed using a client PC. *2 It is not necessary to install LabSolutions software on the client PC for terminal service. *3 When using an ipad, the installation of Citrix s XenApp is required. ipad is a registered trademark of Apple Inc. Simple User Interface Agilent LC method editing Agilent LC batch editing Agilent LC analysis monitoring Launcher window Agilent GC method editing Agilent GC batch editing Agilent GC analysis monitoring 14

15 Fourier Transform Infrared Spectrophotometer IRSpirit IRSpirit, Ready to Run IRSpirit offers the highest S/N ratio in its class and high reliability using the technology inherited from the high-end model. The dedicated IR Pilot program simplifies routine analyses for all users. Gas Chromatograph The Next Industry Standard Nexis GC-2030, Shimadzu's premier gas chromatograph, offers a modern approach to a classic chromatographic technique. Designed with the user in mind, new innovative features, exceptional performance and high-throughput capabilities will elevate your lab to the next level. 15

16 Shimadzu's Total Solutions for the Hydrocarbon Processing Industry For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its subsidiaries or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol TM or. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2018

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Shimadzu Customized GC Analyzers GC-2010 Plus Nexis GC-2030 GC-2014 Natural Gas

More information

Antek Gas Chromatography Products: A Guided Tour Through Industry

Antek Gas Chromatography Products: A Guided Tour Through Industry ANTEK GC Application Solutions Feature the Following Detectors: Antek Sulfur and Nitrogen Chemiluminescence, Flame Ionization, Thermal Conductivity, Nitrogen-Phosphorus, Atomic Emission, Halogen Specific,

More information

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Simulated Distillation Analyzers, Software, Standards, Consumables, Training Simulated Distillation Analyzers, Software, Standards, Consumables, Training www.separationsystems.com Offering the Fullest Range of Optimized Solutions Simulated distillation (SimDis) has been used to

More information

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Refinery Gas Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Refinery Gas Analysis Reliability Placing refinery gas analyzers in the field for over

More information

Refinery and Natural Gas Analysis

Refinery and Natural Gas Analysis Refinery and Natural Gas Analysis 2 ENSURE MORE ACCURATE AND EFFICIENT ANALYSIS TAKE CONTROL OF YOUR OPERATIONS Oil refineries and natural gas producers around the world require their lab operations to

More information

S-PRO 3200 GC System for Sulfur Analysis

S-PRO 3200 GC System for Sulfur Analysis S-PRO 32 GC System for Sulfur Analysis Superior Selectivity and Sensitivity The ability to detect and measure sulfur contaminants in gases is critically important for efficient operation of industrial

More information

Beverage Grade Carbon Dioxide

Beverage Grade Carbon Dioxide Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION The Challenge Carbon dioxide, used in the production of carbonated soft drinks and other beverages,

More information

ANTEK APPLICATED Turn-Key GC solutions

ANTEK APPLICATED Turn-Key GC solutions ANTEK APPLICATED Turn-Key GC solutions The ANTEK advantage Antek patents chemiluminescent nitrogen detection apparatus & method Antek introduces first total nitrogen chemiluminescence analyzer Antek opens

More information

GC Method Compliance and Large Valve Oven Application

GC Method Compliance and Large Valve Oven Application GC Method Compliance and Large Valve Oven Application Solution Focused Kelly Beard June 20, 2016 Compliant Methods Compliant Methods What are our options? Analyzers and Analyzer Kits High Volume Well Known

More information

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural

More information

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different

More information

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS TURN-KEY ANALYZERS GC SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS BROAD ARRAY BROAD OF ARRAY OF CONFIGURATIONS FOR FOR SPECIAL APPLICATIONS SPECIAL THE THE PERFECT ANSWER TO A SEVERELY TO REGULATED A SEVERELY

More information

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Abstract High Temperature Simulated Distillation (High Temp SIMDIS) is one of the most frequently used techniques to determine

More information

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an

More information

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in

More information

Monitor Chlorine in Crude at Sub-ppm Levels

Monitor Chlorine in Crude at Sub-ppm Levels better analysis counts Monitor Chlorine in Crude at Sub-ppm Levels Benchtop and Online Analysis Solutions Total Chlorine Analysis in Liquid Hydrocarbons Clora is a compact analyzer to measure total chlorine

More information

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Based on a New Super Permeable PLOT Column Agilent Select Low Sulfur Johan Kuipers Channel Training Specialist Oct 12 th, 2010 1 October 18,

More information

TSHR 6000 series TN/TS/TX analyzer

TSHR 6000 series TN/TS/TX analyzer TSHR series TN/TS/TX analyzer Versatile, Accurate and Reliable Trace Level Nitrogen, Sulfur, Chlorine Analysis Petrochemicals Refineries Analytical Services Research Analysis The TSHR series TN/TS/TX Analyzer

More information

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Now with New Dual Plasma Technology Overview The Agilent Technologies

More information

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis ASTM 7220 Pooled Limit of Quantitation (PLOQ) of 3 ppm S in a wide variety

More information

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography Dr. Robert Lorenz Analytical Chemist Chevron Energy Technology Company Gulf Coast Conference Galveston, TX October

More information

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces

More information

ASTM D7039. Sulfur analysis plus a further 21 elements by MWDXRF. Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF

ASTM D7039. Sulfur analysis plus a further 21 elements by MWDXRF. Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF Spectrolab Science cat71120p Sulfur analysis plus a further 21 elements by MWDXRF Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF ASTM D7039 and other standards For

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

MESA-7220 Multi-Element Analyzer Using EDXRF Technology THE MESA-7220 X-RAY FLUORESCENCE ANALYZER Measurement of Sulfur and Chlorine in Petroleum Products using Monochromatic, Polarized EDXRF Analysis The MESA-7220 now features an 8-tray turntable. Programmable

More information

On-Line NIR Analysis for Blending

On-Line NIR Analysis for Blending Application Note On-Line NIR Analysis for Blending Introduction Gasoline and Diesel blending is a refinery operation that blends different component streams into various grades of final product. The main

More information

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application Authors Steven M. Wilbur and Emmett Soffey Agilent Technologies 338 146th Place SE Bellevue,

More information

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications C196-E081C Ultra High Performance Liquid Chromatograph Nexera X2 Specifications Specifications System Controllers CBM-20A / 20Alite CBM-20A (228-45012-XX) CBM-20Alite (228-45011-XX) Connectable units Solvent

More information

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in

More information

C2, C3, C4 Monomer Analysis

C2, C3, C4 Monomer Analysis C2, C3, C4 Monomer Analysis Malgorzata Sierocinska Agilent Technologies Waldbronn Page 1 Why Analyze Monomers? To Insure Consistent Production of High Quality Polymer Protect against food contamination

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SOUTHWEST RESEARCH INSTITUTE Office of Automotive Engineering Fuels and Lubricants Research Division 6220 Culebra Road, P.O. Drawer 28510 San Antonio, TX 78228-0510

More information

New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared

New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared John Coates Coates Consulting Process Spectroscopy IFPAC-2014 Thursday PM VIII New Approaches in Spectroscopic Measurements:

More information

IROX 2000 IROX DIESEL

IROX 2000 IROX DIESEL IROX 2000 IROX 2000 Portable Gasoline Analysis with MID-FTIR Features 9 Specific Oxygenates (ASTM D5845) 14 Specific Aromatics and Benzene (ASTM D6277, EN238) Total Aromatics, Oxygen, Olefins (incl. Di-Olefins)

More information

Low cost EDXRF elemental analyzer

Low cost EDXRF elemental analyzer Low cost EDXRF elemental analyzer Sulfur analysis by X-ray fluorescence New ASTM D4294 sulfur-in-oil analyzer from Rigaku combines established functionality with unmatched versatility Sulfur will always

More information

better analysis counts

better analysis counts better analysis counts Application Areas: Upstream desalting, refining, power generation and effluent management. Total chlorine analysis in: - raw and desalted crudes - water and effluent streams - refinery

More information

Agilent and ASTM. Update on Recent Activities. Page 1

Agilent and ASTM. Update on Recent Activities. Page 1 Agilent and ASTM Update on Recent Activities Page 1 ASTM Committees for Refining, Fuels, Petroelum Products ASTM International D2 Petroleum products & lubricants D3 Gas fuels (natural gas) gas fuels D16

More information

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis Metallo-Organic Standards from VHG Labs VHG Labs has been a provider of quality analytical products and services for over 25 years.

More information

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID. Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID. Dedicated PiPNA + FAME For (Bio-)Diesel and Jet Fuels Robust System, Easy to use No Cryogenic coolant Required Keywords:

More information

Application. Gas Chromatography June 1995

Application. Gas Chromatography June 1995 Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee

More information

ElvaX Sulfur in Oil analyzer

ElvaX Sulfur in Oil analyzer ElvaX Sulfur in Oil analyzer Introduction ElvaX Sulfur in Oil was designed especially for analysis of petrochemicals for sulfur content in wide concentration range from ppm to 5%. Many international standards

More information

Analysis of Petroleum Fractions by ASTM D2887

Analysis of Petroleum Fractions by ASTM D2887 Analysis of Petroleum Fractions by ASTM D2887 Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 2582 Key Words Simulated distillation, D2887, TRACE TR-SimDist Abstract ASTM

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that EPA National Vehicle and Fuel Emissions Laboratory

More information

DANI Transformer Oil Gas Analyzer

DANI Transformer Oil Gas Analyzer DANI Transformer Oil Gas Analyzer APPLICATION NOTE - AN169 Introduction Transformers are electrical devices used for energy transfer by electromagnetic induction between two or more circuits. Large oil

More information

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES application Note Biofuels Authors Zoe A. Grosser, Ph.D. Lee J. Davidowski, Ph.D. Pamela Wee PerkinElmer, Inc. Bridgeport Avenue Shelton, CT USA The Analysis of Biodiesel for Inorganic Contaminants, including

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SOUTHWEST RESEARCH INSTITUTE Office of Automotive Engineering Fuels and Lubricants Research Division 6220 Culebra Road, P.O. Drawer 28510 San Antonio, TX 78228-0510

More information

X-ray Essentials from XOS Proven Performance

X-ray Essentials from XOS Proven Performance Petroleum Systems Services Corporation PSSC 2789 State Route 9 Malta, NY 12020-4357 phone: 518-581-0189 fax: 518-581-0201 email: pssc@pssc.org X-ray Essentials from XOS Proven Performance Elemental Analysis

More information

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared Gulf Coast Conference Patrick Ritz PAC LP Global Ethanol Use Consumption of fuel-grade ethanol is on the rise Produced from

More information

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc. 850 Centerville

More information

Sulfur in Oil Analyzer

Sulfur in Oil Analyzer Sulfur in Oil Analyzer The Rigaku NEX QC sulfur in oil analyzer for fuel and lubricating oils MARINE www.insatechmarine.com Insatech MARINE Sulfur in Oil Analyzer Sulfur in Oil Analyzer The ASTM D4294

More information

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds Philipp Jordan eralytics TM GmbH www.eralytics.com Welcome to a new era of petroleum testing PERFORMANCE

More information

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Analysis of Petroleum Samples Using the Teledyne Leeman Labs APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1802 ICP Petroleum Analysis of Petroleum Samples Using the Teledyne Leeman Labs Prodigy Plus ICP-OES John Condon, Applications Chemist and Bruce MacAllister, Applications

More information

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy The world leader in serving science Ultra Fast GC Determination of Total Hydrocarbons (C7-C40) and BTEX in Water and Soils through Direct Resistively Heated capillary columns and Robotic Autosampler. Fausto

More information

Prodigy ICP Application Note: # 1039

Prodigy ICP Application Note: # 1039 Prodigy ICP Application Note: # 1039 The Determination of Trace elements in Biodiesel Fuel using Inductively Coupled Plasma Optical Emission Spectrometry Introduction It is generally accepted that the

More information

Liquid Chromatography Mass Spectrometry LCMS Consumables SSI-LCMS

Liquid Chromatography Mass Spectrometry LCMS Consumables SSI-LCMS Liquid Chromatography Mass Spectrometry LCMS Consumables SSI-LCMS-04-2018 LCMS-2020 Single Quadrupole Mass Spectrometer /8060 225-15718-91 DL Assy * LCMS-2020/8030/8040/8045 Desolvation Line Assembly,

More information

ASTM D2007M/ASTM D2549M In-house method/astm D6560/D3279

ASTM D2007M/ASTM D2549M In-house method/astm D6560/D3279 ID Test Standard Amount Required Price for Cost Recovery Projects (Can $) 1 2 3 4 5 Sulfur compounds distribution by boiling point (GC-SCD) Sulfur compound speciation by GC-SCD Nitrogen compounds distribution

More information

On-Line Process Analyzers: Potential Uses and Applications

On-Line Process Analyzers: Potential Uses and Applications On-Line Process Analyzers: Potential Uses and Applications INTRODUCTION The purpose of this report is to provide ideas for application of Precision Scientific process analyzers in petroleum refineries.

More information

IFPAC 2003 Dr. Berthold Andres

IFPAC 2003 Dr. Berthold Andres IFPAC 2003 Dr. Berthold Andres ABB Automation Products Germany Microelectromechanical Systems for Process Analytics Copyright 2002 ABB. All rights reserved. - Process Analyzer and Instrumentation Water

More information

TSHR 7000 series TN-TS-TX analyzer

TSHR 7000 series TN-TS-TX analyzer TSHR 7000 series TN-TS-TX analyzer Enhanced Capabilities with Powerful Performance for Trace Level Nitrogen, Sulfur, Chlorine Analysis Petrochemicals Refineries Analytical Services Research Analysis The

More information

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES Application note Petrochemical Author Neli Drvodelic Agilent Technologies Melbourne, Australia Introduction

More information

ALL TESTS. Density Oscillating U-tube method * IP 365. Distillation characteristics of petroleum products - Micro distillation method IP 596

ALL TESTS. Density Oscillating U-tube method * IP 365. Distillation characteristics of petroleum products - Micro distillation method IP 596 Tests marked * are ISO17025 accredited ALL TESTS TEST NAME Density Oscillating U-tube * IP 365 Distillation characteristics of petroleum products - Micro distillation IP 596 Mercaptans, hydrogen sulphide,

More information

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion IAS Accreditation Number Company Name Address Contact Name Telephone +966-14-398-2118 Effective Date of Scope May 1, 2018 Accreditation Standard ISO/IEC 17025:2017 TL-743 Yanbu Industrial Area Yanbu, Madina

More information

breakthrough versatility

breakthrough versatility ipro 5000 Series Total Nitrogen/Total Sulfur (TN/TS) Analyzer breakthrough versatility with exceptional accuracy and precision Petrochemicals Refineries Chemical Plants Commercial Testing Laboratories

More information

Petroleum and Natural Gas

Petroleum and Natural Gas Raw Material Identification Thermo Scientific Oil and Gas to Quality Assurance Petroleum and Natural Gas Analysis Workflows Gas Chromatography Gas Chromatography Mass Spectrometry Ion Chromatography Combustion

More information

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany Determination of Aromatic Hydrocarbons in Petroleum Middle Distillates with the Agilent Infinity Binary HPLC System with RID Detection According to IP9()/ASTM D9 Application Note Energy & Chemicals - Petrochemicals

More information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville

More information

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer Advanced Petrochemical Applications With ICP-OES Tina Harville, Ph.D. Application Engineer Elemental Analysis of Petrochem-Based Solutions Refineries and Petrochemicals Sulfur content of gasoline Acceptance

More information

Using the PSD for Backflushing on the Agilent 8890 GC System

Using the PSD for Backflushing on the Agilent 8890 GC System Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped

More information

On-Line NIR Analysis of Crude Distillation Unit

On-Line NIR Analysis of Crude Distillation Unit Application Note On-Line NIR Analysis of Crude Distillation Unit Introduction Petroleum refining is the process of separating the many compounds present in crude petroleum. The principle which is used

More information

WEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony. October 31,

WEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony. October 31, WEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony October 31, 2012 1 WDXRF for Petrochemical Analysis: More Than a One-Trick Pony Arkady Buman Product Manager XRF North America Today

More information

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W

More information

Elemental Analysis Advanced

Elemental Analysis Advanced better analysis counts Elemental Analysis Advanced Rapid sulfur measurement plus 12 elements from P to Zn. ASTM D4294 ISO 8754 IP 336 Advanced Software and Data Management Petra offers the latest software

More information

Correlating TBP to Simulated Distillations. COQA Long Beach, CA

Correlating TBP to Simulated Distillations. COQA Long Beach, CA Correlating TBP to Simulated Distillations COQA Long Beach, CA 2017-10-05 Maxxam Analytics Overview Maxxam Analytics A Bureau Veritas Group Company 69,000 1,400 3 Maxxam Analytics Part of the Bureau Veritas

More information

Elemental Analysis of Biofuels with SPECTRO XRF and ICP Spectrometers

Elemental Analysis of Biofuels with SPECTRO XRF and ICP Spectrometers Elemental Analysis of Biofuels with SPECTRO XRF and ICP Spectrometers With a complete range of Energy Dispersive X-ray Fluorescence (ED-XRF) and Inductively Coupled Plasma Optical Emission (ICP-OES) Spectrometers,

More information

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent

More information

High-Temperature Simulated Distillation System Based on the 6890N GC Application

High-Temperature Simulated Distillation System Based on the 6890N GC Application High-Temperature Simulated Distillation System Based on the 6890N GC Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co., Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai

More information

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Application Note Hydrocarbon Processing Authors ChunXiao Wang Agilent Technologies

More information

Annex no. 1 of Accreditation Certificate no. LI 333 from

Annex no. 1 of Accreditation Certificate no. LI 333 from Valid from 04.02.2008 to 04.02.2012 Oil Products Laboratory DJ No. 226, Nvodari, Constana county belonging to SC ROMPETROL QUALITY CONTROL SRL 1 2 3 4 Physical tests 1. Determination of the density with

More information

URB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C)

URB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C) O NH O NH O. GENERAL INFORMATION IUPAC Name: 3'-carbamoylbiphenyl-3-yl cyclohexylcarbamate CAS#: 56-08-6 Synonyms: Source: Appearance: UV max (nm): KDS-03 DEA Reference Material Collection White powder

More information

Technical Procedure for Gas Chromatography (GC-FID)

Technical Procedure for Gas Chromatography (GC-FID) Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all

More information

Application Note. Authors. Abstract. Energy & Chemicals

Application Note. Authors. Abstract. Energy & Chemicals Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors

More information

GC MERGE OF LIGHT ENDS WITH ASTM D7169 BOILING POINT DISTRIBUTION

GC MERGE OF LIGHT ENDS WITH ASTM D7169 BOILING POINT DISTRIBUTION GC MERGE OF LIGHT ENDS WITH ASTM D7169 BOILING POINT DISTRIBUTION Crude Oil Quality Association St. Louis, MO June 8, 2017 Arden Strycker, Ph.D. SGS North America Providing Solutions Across the Value Chain

More information

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9 Foreword...xi Acknowledgments...xiii Introduction... xv Chapter 1 Engine Emissions...1 1.1 Characteristics of Engine Exhaust Gas...1 1.1.1 Major Components of Engine Exhaust Gas...1 1.1.2 Units Used for

More information

SCOPE OF ACCREDITATION

SCOPE OF ACCREDITATION Standards Council of Canada 600-55 Metcalfe Street Ottawa, ON K1P 6L5 Canada Conseil canadien des normes 55, rue Metcalfe, bureau 600 Ottawa, ON K1P 6L5 Canada SCOPE OF ACCREDITATION InnoTech Alberta Inc.

More information

a review of analytical methods for the quantification of aromatics in diesel fuels

a review of analytical methods for the quantification of aromatics in diesel fuels a review of analytical methods for the quantification of aromatics in diesel fuels Prepared for the Automotive Emissions Management Group by the Special Task Force on Diesel Fuel Emissions (AE/STF-7) P.

More information

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and

More information

Experience the Difference

Experience the Difference ABB-Totalflow Experience the Difference PGC1000 Process Gas Chromatograph ABB Group October 19, 2011 Slide 1 Process GC Experience ABB introduced the Btu-8000 in 1995 C6+ application suitable for custody

More information

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS ULTRA CLEAN GAS FILTERS ULTRA CLEAN GAS FILTERS Table of Contents Ultra Clean Gas Filter s for GC and GC/MS...3 Triple Filter for MS/ECD/NPD... 3 Complete Triple Filter Bundle for FID...3 Complete Triple

More information

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Technical Overview Trace gas analysis is a challenge in today s world. The ability to analyze lower component

More information

Article: The Formation & Testing of Sludge in Bunker Fuels By Dr Sunil Kumar Laboratory Manager VPS Fujairah 15th January 2018

Article: The Formation & Testing of Sludge in Bunker Fuels By Dr Sunil Kumar Laboratory Manager VPS Fujairah 15th January 2018 Article: The Formation & Testing of Sludge in Bunker Fuels By Dr Sunil Kumar Laboratory Manager VPS Fujairah 15th January 2018 Introduction Sludge formation in bunker fuel is the source of major operational

More information

White Paper.

White Paper. The Advantage of Real Atmospheric Distillation Complying with the ASTM D7345 Test Method in the Distillation Process Introduction / Background In the past, refiners enjoyed a constant supply of the same

More information

Analytical and Testing Instruments for Renewable Fuels. Shimadzu s Analytical Solutions for the Renewable Fuels Industry

Analytical and Testing Instruments for Renewable Fuels. Shimadzu s Analytical Solutions for the Renewable Fuels Industry Analytical and Testing Instruments for Renewable Fuels Shimadzu s Analytical Solutions for the Renewable Fuels Industry Biofuels from Ancient History to Today Biofuels and bioenergy are as old as civilization

More information

ISO 8754 INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Energy-dispersive X-ray fluorescence spectrometry

ISO 8754 INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Energy-dispersive X-ray fluorescence spectrometry Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 8754 Second edition 2003-07-15 Petroleum products Determination of sulfur content Energy-dispersive X-ray fluorescence spectrometry Produits pétroliers

More information

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials The Stability of Sulfur s, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials Linda Coyne Cindy Kuhlman Nicole Zovack SKC Inc. Eighty Four, PA 15330 25 January 2011 Publication 1805

More information

X-ray Analysis in Petrochemical and Polymer Industries: Challenges and Solutions

X-ray Analysis in Petrochemical and Polymer Industries: Challenges and Solutions Gulf Coast Conference 2014 X-ray Analysis in Petrochemical and Polymer Industries: Challenges and Solutions Al Martin Thermo Fisher Scientific, West Palm Beach, USA XRF Petro and Poly Challenges Physical

More information

Bright prospects Solvents for spectroscopy Uvasol

Bright prospects Solvents for spectroscopy Uvasol Bright prospects Solvents for spectroscopy Uvasol EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Simply the best UV/VIS and infrared spectroscopy are reliable and accurate methods

More information

Proposal to establish a laboratory for combustion studies

Proposal to establish a laboratory for combustion studies Proposal to establish a laboratory for combustion studies Jayr de Amorim Filho Brazilian Bioethanol Science and Technology Laboratory SCRE Single Cylinder Research Engine Laboratory OUTLINE Requirements,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATORY & ON-STREAM ANALYSER DIVISION, SAUDI ARAMCO TOTAL REFINING AND PETROCHEMICAL COMPANY LAB & OSA Division Saudi Aramco Total Refining and Petrochemical

More information

Distillation process of Crude oil

Distillation process of Crude oil Distillation process of Crude oil Abdullah Al Ashraf; Abdullah Al Aftab 2012 Crude oil is a fossil fuel, it was made naturally from decaying plants and animals living in ancient seas millions of years

More information

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS) Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the pyrolysis-gas chromatograph-mass spectrometer

More information

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co.,Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai

More information