GC Method Compliance and Large Valve Oven Application
|
|
- Lilian Strickland
- 5 years ago
- Views:
Transcription
1 GC Method Compliance and Large Valve Oven Application Solution Focused Kelly Beard June 20, 2016
2 Compliant Methods
3 Compliant Methods What are our options? Analyzers and Analyzer Kits High Volume Well Known Analysis Many Options Application Notes Lower Volume Usually Requires a Consultant Possible Future Analyzer, Given Acceptable Sales Quantiles Channel Partner Solutions Requires Third Party Software or Requires Third Party Hardware 3 June 27, 2016
4 Analyzers and Application Kits Updated HPI Solution Guide Searchable, 139 pages PN: EN Links to Analyzer Chapter 4 Analyzer Overview January 2013
5 Analyzers and Application Kits 5 Analyzer Overview January 2013
6 Analyzers and Application Kits 6 Analyzer Overview January 2013
7 Analyzers and Application Kits 7 Analyzer Overview January 2013
8 Analyzers and Application Kits 8 Analyzer Overview January 2013
9 Application Notes Example: D5769 Determination of Benzene, Toluene, Total Aromatics in Finished Gasolines by Gas Chromatography/Mass Spectrometry Fred Feyerherm developed application, via ASTM method Very successful Custom Calculations Consultant is Requited for Application Very popular lately Sales Quantities have Increased Analyzer Kit In Developed as a Result 9 Analyzer Overview January 2013
10 Channel Partner ASTM D6730 Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-meter Capillary (with PreColumn) High Resolution Gas Chromatography Detailed Hydrocarbon Analysis Difficult Analysis with 100 s of Compounds Requires Custom Software Software is Difficult to Support via Agilent Field Resources Many Software and Third Party Providers 10 Analyzer Overview January 2013
11 Channel Partner ASTM D5599 Standard Test Method for Determination of Oxygenates in Gasoline by Gas Chromatography and Oxygen Selective Flame Ionization Detection O-FID Analysis Requires a Custom Platinum Catalyst Requires Custom Reporting Hardware can not be Supplied by Agilent Wasson-ECE is our Partner of Choice for this Analysis with Many Years of Experience on the Application. 11 Analyzer Overview January 2013
12 Channel Partner ASTM D8003 Standard Test Method for Determination of Light Hydrocarbons and Cut Point Interals in Live Crude Oils and Condensates by Gas Chromatography New Live Crude Oil Analysis Requires HPLIS Third Party Injection Source Intended for the introduction of pressurized liquid samples containing very polar, high boiling or high carbon number analytes Requires Custom Reporting Hardware can not be Supplied or Supported by Agilent 12 Analyzer Overview January 2013
13 Channel Partner Reformulyzer - Hydrocarbon Group Type Analysis PAC Provided Solution Test Methods: ASTM D5443, ASTM D6839, IP 566, EN ISO 22854, SH/T 0741, GB/T , GOST R EN ISO Intended for the introduction of pressurized liquid samples containing Extensive Hardware Addition 13 Analyzer Overview January 2013
14 Questions 14 Analyzer Overview January 2013
15 Introducing the 7890B Large Valve Oven Isothermal Zone for Valves and Columns Temperature control: - Independent control of LVO and GC oven zones Temperature Limit: - Max 330 C (valve and column dependent) Valve configurations: - Accommodates 4/6/10/14 port valves including Hastelloy valves Column Compatibility: - Large Mandrel: Accommodates 15 feet of 1/8 inch OD metal column - Small Mandrel: Accommodates 7 Ft of 1/8 OD metal column 15 LVO Analyzer Training June 27, 2016
16 Introducing the 7890B Large Valve Oven Isothermal Zone for Valves and Columns Column Mandrel Valve or Mandrel Position 6 Internal Positions: Valves or Columns Variable Restrictor - Up to six (6) heated valve positions - Four (4) needle valve positions - Uses 1 heated zone 6-port Valve 12-port Valves 16 LVO Analyzer Training June 27, 2016
17 Large Valve Oven Features/Benefits Feature 6 position isothermal valve oven for actuated valves, microgasifiers, needle valves, and columns (including 1/8 in packed columns) with access to valves connections without removing actuators Benefit Open configuration that allows for easy maintenance; maximizing up-time. Also allows for multiple configurations for method development as well as set SP1 and configured Feature Use only one 7890B heated zone Benefit Current multi-valve configurations may quickly consume 6 heated zones, LVO uses 5 leaving 1 for future applications Feature Dual thermal zones allow for thermal isolation between column oven and LVO Benefit Ability to configure analyses that require multiple thermal zones. Can run isothermal temperatures in the LVO while temperature ramping the GC oven 7890B with Large Valve Oven 17 LVO Analyzer Training June 27, 2016
18 Fast Refinery Gas Analysis with Micropacked Columns Simultaneous O 2 and H 2 S determination 7890 GC System, LVO, Column, Sample Option 112 S/SL Inlet G3445B Option #532 Option 210 FID with EPC Option 220 TCD with EPC Option 221 Left Mount TCD Option 002 or 003 Fast Oven Option 311 and 312 Cryo 18 LVO Analyzer Training June 27, 2016
19 Performance Features LVO RGA Analyzers Fast RGA Analyzer Total run time is 8 minutes - LVO at 70 C Hydrocarbons to C 5 (C 6+ backflush) Permanent Gases O 2 and H 2 S Compounds Limit Hydrocarbons 0.01 Mol% Hydrogen Sulfide 500 ppm Carbonyl Sulfide 300 ppm Hydrogen 0.01 Mol% O2, N2, CO, CO Mol% June 27,
20 Fast RGA with Micropacked Columns GC/FID/TCD/TCD Micropack LVO Plumbing Micropack System Flow Diagram 20 LVO Analyzer Training June 27, 2016
21 Fast RGA with Micropacked Columns Helium Carrier Selected Method Parameters Split/Splitless inlet: 120 ºC, 100:1 split FID (front): 250 ºC TCD (rear): 260 ºC He carrier Ref. 30 ml/min Makeup 2 ml/min TCD (side): 250 ºC N2 carrier Ref. 45 ml/min Makeup 2 ml/min, neg. polarity Main Oven Program: 60 ºC ( 1 min) to ºC/min to ºC/min Large Valve Oven: Isothermal, 65 ºC and 70 ºC 21 LVO Analyzer Training June 27, 2016
22 Fast RGA with Micropacked Columns Analytical Performance Hydrocarbon Channel (FID), LVO at 70 C 22 LVO Analyzer Training June 27, 2016
23 Fast RGA with Micropacked Columns Analytical Performance Permanent Gas Channel (TCD), LVO at 70 C LVO Analyzer Training June 27, 2016
24 Fast RGA with Micropacked Columns Analytical Performance Oxygen Stability 70 C 75 C Stability of Oxygen Isothermal Oven at 70 C Stability of Oxygen Isothermal Oven at 75 C 24 LVO Analyzer Training June 27, 2016
25 Fast RGA with Micropacked Columns Helium Carrier Application Note Fast Refinery Gas Analysis System Based on the Agilent 7890B GC System and G3507A Large Valve Oven Using Micropacked Columns 25 LVO Analyzer Training June 27, 2016
26 Simultaneous analysis of hydrogen hydrocarbons and permanent gases Fast RGA LVO Analyzer Value Overview Analyzer, G3445B #532 Large Valve Oven External Thermal Zone Isothermal Operation Up to 6 valves or columns Expands capability of 7890 Micropacked Columns Built for speed Rapid 8 minute cycle time Isothermal Zone Protect temperature sensitive columns Simultaneous analysis of hydrogen disulfide (H 2 S) and oxygen (O 2 ) Stable response for oxygen (O 2 ) Three Channel Analytical Method Simultaneous analysis of O 2 and H 2 S <8 Minutes GC/FID/MS Blood Alcohol Analyzer February
27 LVO Based Fast RGA with Hydrogen Carrier Analytical Performance (G3445B, #533 Available on July 1, 2014 CPL) FID Channel C6+ 27 LVO Analyzer Training June 27, 2016
28 Fast Refinery Gas Analysis with Micropacked Columns Simultaneous O 2 and H 2 S determination using Hydrogen Carrier Gas 7890 GC System, LVO, Column, Sample Option 112 S/SL Inlet G3445B Option #533 Option 210 FID with EPC Option 220 TCD with EPC Option 221 Left Mount TCD Option 002 or 003 Fast Oven Option 311 and 312 Cryo 28 LVO Analyzer Training June 27, 2016
29 Overview - GC Platforms & Positioning 7820 GC Entry Level LTM /7890 GC Fast heating/ cooling Price/Performance 490 Micro GC Fast Gas Analysis Compact Size 7890 GC Highest flexibility Industry leader Technologies 6850 GC Small footprint Page 29 Gas Chromatograph Agilent Restricted
30 Thank You. Page 30 HPI Solution overview Agilent Restricted Neophyte training Shanghai,Sep, 2007
Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.
Refinery Gas Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Refinery Gas Analysis Reliability Placing refinery gas analyzers in the field for over
More informationApplication. Gas Chromatography June 1995
Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee
More informationGas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593
Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent
More informationAgilent and ASTM. Update on Recent Activities. Page 1
Agilent and ASTM Update on Recent Activities Page 1 ASTM Committees for Refining, Fuels, Petroelum Products ASTM International D2 Petroleum products & lubricants D3 Gas fuels (natural gas) gas fuels D16
More informationHigh Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph
Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent
More informationAgilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist
Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass James D. McCurry, Ph.D. Senior Scientist Agilent Solutions for the Analysis of Ethanol-Based Fuels Derived From Biomass Presented
More informationUsing a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application
Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville
More informationAntek Gas Chromatography Products: A Guided Tour Through Industry
ANTEK GC Application Solutions Feature the Following Detectors: Antek Sulfur and Nitrogen Chemiluminescence, Flame Ionization, Thermal Conductivity, Nitrogen-Phosphorus, Atomic Emission, Halogen Specific,
More informationOxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels
Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels James D. McCurry Senior Scientist Agilent Technologies Wilmington, DE USA Page 1 Application Summary There is a need to measure
More informationOptimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE
Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System Jim McCurry Roger Firor Agilent Technologies Wilmington, DE Page 1 Scope of the Analyzer Designed for ASTM D7798 For
More informationTechnical Procedure for Gas Chromatography (GC-FID)
Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all
More informationBeverage Grade Carbon Dioxide
Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION The Challenge Carbon dioxide, used in the production of carbonated soft drinks and other beverages,
More informationApplication Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER
Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in
More informationperformance productivity reliability
Solutions that meet your demands for: performance productivity reliability Excellent Choices for Global Hydrocarbon Processing Applications Crude Oil & Natural Gas Natural Gas > Return to Table of Contents
More informationLiquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases
Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an
More informationUsing the PSD for Backflushing on the Agilent 8890 GC System
Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped
More informationPRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System
Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and
More informationC2, C3, C4 Monomer Analysis
C2, C3, C4 Monomer Analysis Malgorzata Sierocinska Agilent Technologies Waldbronn Page 1 Why Analyze Monomers? To Insure Consistent Production of High Quality Polymer Protect against food contamination
More informationAgilent Multimode Inlet for Gas Chromatography
Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything
More information2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx
2-D GC/MS and the Deans Switch: Theory and Applications Fred Feyerherm, Agilent Technologies Inc. Houston, Tx Introduction Simplified 2-D GC can be used to accomplish the separation of specific analytes
More informationFast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application
Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co.,Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai
More informationOperation and Applications of Differential Flow Modulation
Operation and Applications of Differential Flow Modulation H2 Collection channel Column 1 H2 Column 2 FID Roger L Firor, Ph.D. Agilent Technologies Chemical Analysis Group Wilmington, DE USA Flow Modulator
More informationAchieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)
Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,
More informationDetection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector
Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural
More informationASTM D 6730 Detailed Hydrocarbon Analysis
ASTM D 6730 Detailed Hydrocarbon Analysis Jaap de Zeeuw, Jan Pijpelink and Barry Burger Restek Corporation ASTM D 6730-01(2006)e1 Determination of Individual Components in Spark Ignition Engine Fuels as
More informationTechnical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)
Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph-mass spectrometer (GC-MS). 2.0 Scope
More informationThe Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector
Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces
More informationExperience the Difference
ABB-Totalflow Experience the Difference PGC1000 Process Gas Chromatograph ABB Group October 19, 2011 Slide 1 Process GC Experience ABB introduced the Btu-8000 in 1995 C6+ application suitable for custody
More informationModel 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors
Model 8610C Gas Chromatograph Mounts up to Six Detectors and Five Injectors Ambient to 400 C Temperature Programmable Column Ovens Dimensions: 19 wide x 13.5 high x 14.5 deep Implement virtually any EPA
More informationAlternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis
Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different
More informationApplication Note. Abstract. Authors. Environmental Analysis
High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research
More informationPage 1. Alternate Carrier Gas Considerations and Faster GC Analysis
Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down
More informationDANI Transformer Oil Gas Analyzer
DANI Transformer Oil Gas Analyzer APPLICATION NOTE - AN169 Introduction Transformers are electrical devices used for energy transfer by electromagnetic induction between two or more circuits. Large oil
More informationSetting up SilFlow for BackFlush in your GC
Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile
More informationHigh Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System
High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System Application Note Authors Frank David Research Institute for Chromatography, Pres.
More informationSimulated Distillation Analyzers, Software, Standards, Consumables, Training
Simulated Distillation Analyzers, Software, Standards, Consumables, Training www.separationsystems.com Offering the Fullest Range of Optimized Solutions Simulated distillation (SimDis) has been used to
More informationIncreased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel
Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W
More informationDual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis
Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Now with New Dual Plasma Technology Overview The Agilent Technologies
More informationSELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS
Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in
More informationASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column
ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column Cory S. Fix, Director of Application Development cory.fix@vgcchromatography.com Willie Steinecker,
More information6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR
6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR A15836 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use
More informationTURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS
TURN-KEY ANALYZERS GC SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS BROAD ARRAY BROAD OF ARRAY OF CONFIGURATIONS FOR FOR SPECIAL APPLICATIONS SPECIAL THE THE PERFECT ANSWER TO A SEVERELY TO REGULATED A SEVERELY
More informationTechnical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)
Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the pyrolysis-gas chromatograph-mass spectrometer
More informationFast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC
Fast GC SPEEDY GC Slide 4 Optimization Goals Primary: Minimize time for the separation of a given number of peaks Secondary: Maximize the number of peaks separated by a given column Slide 5 HOW CAN THESE
More informationAgilent 6850 Series II Network GC System G2630A Performance Specifications
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6850 Series II Network GC
More informationLarge Volume Injection of Polycyclic Aromatic Hydrocarbons
JSB is an authorised partner of Large Volume Injection of Polycyclic Aromatic Hydrocarbons Application Note - Environmental #113 Author Anne Jurek Applications Chemist EST Analytical Cincinnati, OH Abstract
More informationImpact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter
Cd The Chrom Doctor Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Jaap de Zeeuw, Restek Corporation, Middelburg, The Netherlands. In Part 1 of this series we focused
More informationGAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS
GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour
More informationAnalytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Shimadzu Customized GC Analyzers GC-2010 Plus Nexis GC-2030 GC-2014 Natural Gas
More informationSulfur Detection at ppb Levels in Light Hydrocarbon Streams
Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Based on a New Super Permeable PLOT Column Agilent Select Low Sulfur Johan Kuipers Channel Training Specialist Oct 12 th, 2010 1 October 18,
More informationHigh-Temperature Simulated Distillation System Based on the 6890N GC Application
High-Temperature Simulated Distillation System Based on the 6890N GC Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co., Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai
More informationFast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC
Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Technical Overview Trace gas analysis is a challenge in today s world. The ability to analyze lower component
More informationRestek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades
High Speed PONA Analysis For Detailed Hydrocarbon Analysis Extended (DHAX) Using Hydrogen Carrier Gas For The Determination of Individual Components In Spark Ignition Fuels Barry L. Burger, Neil Johansen,
More informationAgilent G2855A Deans Switching System
Agilent G2855A Deans Switching System Installation and Operation Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that EPA National Vehicle and Fuel Emissions Laboratory
More informationRefinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography
Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography Dr. Robert Lorenz Analytical Chemist Chevron Energy Technology Company Gulf Coast Conference Galveston, TX October
More informationTroubleshooting Tips & Tricks for your GC Analyzer & CFT Application
Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application 7890A/7890B GC Overview October 29, 2014 1 Definitions Carrier Gas Pressurized gas used to transport the sample through the system.
More informationANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE
ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE + INGRID CITY GATE STATION INGRID GAS CONTROL CENTER What is? H2 INJECTION is a modular multi-function system based on:, A NEW METHOD OF MANAGING THE
More informationSimple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer
Simple Heart Cutting with Deans Switch and Backflushing with Capillary Flow Technolgy Simon Jones Applications Engineer GC or GC/MS Analysis in Complex Matrices In complex sample matrices, there are often
More informationMethod Development for Capillary GC Systems. Slide 1
Method Development for Capillary GC Systems Slide 1 AREAS TO OPTIMIZE Injector Carrier gas Column temperature Slide 2 COMMON INJECTOR MODES Vaporization Injection Modes Megabore Direct Split Splitless
More informationAgilent Technologies GPSD Analyzer Solutions
Agilent Technologies GPSD Analyzer Solutions Agilent Science and Technology Symposium 1 What is an Analyzer An Analyzer is a factory-configured GC or GC/MSD system configured, tuned and tested for the
More informationDual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector
Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Application Note Hydrocarbon Processing Authors ChunXiao Wang Agilent Technologies
More informationThe Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials
The Stability of Sulfur s, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials Linda Coyne Cindy Kuhlman Nicole Zovack SKC Inc. Eighty Four, PA 15330 25 January 2011 Publication 1805
More informationRefinery and Natural Gas Analysis
Refinery and Natural Gas Analysis 2 ENSURE MORE ACCURATE AND EFFICIENT ANALYSIS TAKE CONTROL OF YOUR OPERATIONS Oil refineries and natural gas producers around the world require their lab operations to
More informationDETECTORS Photo Ionization Detector - PID. Overview
Overview DETECTORS The Photo Ionization Detector (PID) responds to all molecules whose ionization potential is below 10.6eV, including aromatics and molecules with carbon double bonds. The PID is nondestructive,
More informationApplication Note. Authors. Abstract. Energy & Chemicals
Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors
More informationPortable TOC Analyser for Stack Emissions
Portable TOC Analyser for Stack Emissions Lightweight, compact, safe and SMART Size and Weight SPECIFICATIONS 355(W) x 155(H) x 426(D) mm, 10 Kg (with batteries 13,4 Kg) Power Supply External Power Adapter
More information6890 Installing ¼ Glass Columns
6890 Installing ¼ Glass Columns A15891 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this material. The information
More informationIFPAC 2003 Dr. Berthold Andres
IFPAC 2003 Dr. Berthold Andres ABB Automation Products Germany Microelectromechanical Systems for Process Analytics Copyright 2002 ABB. All rights reserved. - Process Analyzer and Instrumentation Water
More informationLightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
More informationGC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585
GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc. 850 Centerville
More informationAgilent 7693A Automated Liquid Sampler
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7693A Automated Liquid Sampler
More informationAnalysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID
Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID Introduction P Gorst-Allman (LECO Africa Pty. Ltd) and B-J de Vos (NMISA). The analysis
More informationAnalysis of Petroleum Fractions by ASTM D2887
Analysis of Petroleum Fractions by ASTM D2887 Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 2582 Key Words Simulated distillation, D2887, TRACE TR-SimDist Abstract ASTM
More informationQuantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application
Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application Authors Steven M. Wilbur and Emmett Soffey Agilent Technologies 338 146th Place SE Bellevue,
More informationUltra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS
ULTRA CLEAN GAS FILTERS ULTRA CLEAN GAS FILTERS Table of Contents Ultra Clean Gas Filter s for GC and GC/MS...3 Triple Filter for MS/ECD/NPD... 3 Complete Triple Filter Bundle for FID...3 Complete Triple
More informationSTI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Extended range HPLC has been investigated for many years; however, progress was delayed because of
More informationS-PRO 3200 GC System for Sulfur Analysis
S-PRO 32 GC System for Sulfur Analysis Superior Selectivity and Sensitivity The ability to detect and measure sulfur contaminants in gases is critically important for efficient operation of industrial
More informationAnalysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices
Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices GC Application Chemist March 3rd, 2008 Pittcon 2008, New Orleans, LA Presentation Outline WCOT vs. PLOT columns OxyPLOT A highly
More informationInstalling a Purged Packed Inlet
Installing a Purged Packed Inlet Agilent 6850 Gas Chromatograph This kit contains: Accessory G2651A Description Purged packed column inlet system 1 Top block insulation 1 Bottom block insulation 1 Insulation
More informationMET-Biodiesel Capillary GC Columns
MET-Biodiesel Capillary GC Columns Product Specifications Product Features & Benefits Chromatograms FAQs Related Products Updated: February 2, 2009 Product Specifications 2 Product Specifications What
More informationWhite Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information
Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Abstract High Temperature Simulated Distillation (High Temp SIMDIS) is one of the most frequently used techniques to determine
More informationDetailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns
Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Compatible with hydrogen, for 50% faster run times. Improved resolution between oxygenates and hydrocarbons, for more accurate reporting. Individually
More informationGC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method
GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN1413:211 Method Application Note Author James D. McCurry, Ph.D. Agilent Technologies Abstract
More informationAppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS
AppNote 6/26 Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) Andreas Hoffmann GERSTEL GmbH & Co.KG, Eberhard-Gerstel-Platz 1,
More informationFor more information about Agilent Technologies services please visit our web site using the following URL
Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained and certified
More informationAnalysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA
Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices Simon Jones Application Engineer Folsom, CA August 20, 2009 Agenda WCOT vs. PLOT columns OxyPlot A Unique stationary phase
More informationTHC Heated FID 3-300A
Rack Mount/Table Top TVOC Analyzer THC Heated FID 3-300A Space saving 19"/3PU space saving rack mount and table top heated emission analyzer for the continuous determination of the mass concentration of
More informationTSHR 6000 series TN/TS/TX analyzer
TSHR series TN/TS/TX analyzer Versatile, Accurate and Reliable Trace Level Nitrogen, Sulfur, Chlorine Analysis Petrochemicals Refineries Analytical Services Research Analysis The TSHR series TN/TS/TX Analyzer
More informationAgilent 7693A Automated Liquid Sampler
Agilent 7693A Automated Liquid Sampler Specifications Overview The Agilent 7693A is a state-of-the-art sample handling and injection system that provides the highest levels of precision and reliability
More informationFausto Munari e Andrea Cadoppi ThermoFisher - Italy
The world leader in serving science Ultra Fast GC Determination of Total Hydrocarbons (C7-C40) and BTEX in Water and Soils through Direct Resistively Heated capillary columns and Robotic Autosampler. Fausto
More informationGroup-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.
Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID. Dedicated PiPNA + FAME For (Bio-)Diesel and Jet Fuels Robust System, Easy to use No Cryogenic coolant Required Keywords:
More informationANTEK APPLICATED Turn-Key GC solutions
ANTEK APPLICATED Turn-Key GC solutions The ANTEK advantage Antek patents chemiluminescent nitrogen detection apparatus & method Antek introduces first total nitrogen chemiluminescence analyzer Antek opens
More informationURB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C)
O NH O NH O. GENERAL INFORMATION IUPAC Name: 3'-carbamoylbiphenyl-3-yl cyclohexylcarbamate CAS#: 56-08-6 Synonyms: Source: Appearance: UV max (nm): KDS-03 DEA Reference Material Collection White powder
More informationCustomer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard
Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained and certified
More informationGB Translated English of Chinese Standard: GB NATIONAL STANDARD
Translated English of Chinese Standard: GB17930-2016 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 75.160.20 E 31 GB 17930-2016 Replacing
More informationPerforming ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software
Install a capillary column in the oven of the SRI GC. The ASTM method suggests a 12 meter.32mm id narrow-bore column coupled with a 2.5 meter guard column but permits the use of any column which exhibits
More informationGas chromatography technology advancement: the new ABB PGC 5000 Marco Quiles
Gas chromatography technology advancement: the new ABB PGC 5000 Marco Quiles ABB - 1 - PGC - Process Gas Chromatograph PGC2007 PGC2009 Physical Size Large PGC2000 PGC5000 PGC1000 Small I II III IV Application
More informationTypical Gas Chromatographic System
Page 72 Air Hydrogen Carrier Gas Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer Cylinders or Generators Flow Controller Column Recorder/
More informationGC Inlets. An Overview. Simon Jones GC Applications Engineer
GC Inlets An Overview Simon Jones GC Applications Engineer Types of Inlets Purged Packed Split / Splitless Cool On Column Programmable Temperature Vaporization Volatiles Interface Multi Mode Inlet Where
More information