C2, C3, C4 Monomer Analysis

Size: px
Start display at page:

Download "C2, C3, C4 Monomer Analysis"

Transcription

1 C2, C3, C4 Monomer Analysis Malgorzata Sierocinska Agilent Technologies Waldbronn Page 1

2 Why Analyze Monomers? To Insure Consistent Production of High Quality Polymer Protect against food contamination in food packaging Protect Catalysts from Irreversible Poisoning Increase Time between Catalyst Changes Better Market Position for Product Sales Higher product quality = higher price Page 2

3 Compounds to be Analyzed in HP Olefin Monomers Oxygenates Sulfurs Ammonia Arsine Phosphine Chlorides A Solution for Monomer Impurities Page 3

4 Pressurized Liquids Injector Simple, No transfer line, High pressure, Automatic operation and long service life Syringe Body replaced by Liquid Valve 4-Port LS Valve Removable Needle installed on one Port of valve Page 4

5 FLOW DIAGRAM Of The Injection Device (6) Restrictor (5) Fused silica tubing Sample Out (4) Filter W Sample In S (1) Valve C P (3) EPC Split Vent Carrier Gas (2) Needle FID Column Figure 1, Flow Diagram of HPID Page 5

6 Hydrocarbon Impurities in Propylene by FID 1. methane 2. ethane 3. ethylene 4. propane 5. Propylene 6. Acetylene 7. i-butane 8. Propadiene 9. n-butane t-2-butene butene 12. Isobutylene 13. c-2-butene 14. Methyl acetylene 15. 1,3-butadiene Page 6

7 Hydrocarbon Impurities in of Ethylene M Deactivated Alumina PLOT Column 50 m x 530 mm methane 6 acetylene 11 1-butene 2 ethane 7 isobutane 12 isobutylene 3 ethylene 8 propadiene 13 c-2-butene 4 propane 9 n-butane 14 methylacetylene 5 propylene 10 t-2-butene 15 1,3-butadiene Excess resolution will allow shorter columns Page 7

8 14X Faster Than Original Method Faster analysis and shorter cycle time achieved by Shorter column - 10 meter Increasing the temperature programming rate Higher starting temperature and lower end temperature Page 8

9 Impurities in Pressurized 1, 3-Butadiene 1, Methane; 2, Ethane; 3, Ethylene; 4, Propane; 5, Propylene; 6, i-butane; 7, n-butane; 8, t-2-butene; 9, 1-Butene; 10, i-butene; 11, c-2-butene; 12, i-pentane; 13, n-pentane; 14, n-hexane; 15, 1,3-Butadiene; 16, 1-Pentene; 17, c-2-pentene; 18, Hexane; 19, Toluene; 20, Dimer Oven: 35 C, 2 min. 10C/min to 195 C, 16 min. Column: PLOT AL2O3/ KCL (PN:3352), 30m, 0.53mm,15ul Flow 10 ml/min, Split flow: 150 Sampling Valve:05W-0056V, 0.5ul (180 psi) Page 9

10 Impurities in Liquified Propylene 1, Methan; 2, Ethane; 3, Ethylene; 4, Propane; 5, Propylene; 6, i-butane; 7, n-butane 8, t-2-butene; 9, 1-Butene; 10, i-butene; 11,c-2-Butene; 12, i-pentane; 13, n-petane; 14, n-hexane Oven: 35 C, 10 min. 10C/min 190 C 3 min. Column: PLOT AL2O3/ KCL PN:3352, 30m, 0.53mm,15ul Flow 10 ml/min, psi Split flow: 150.3; Total 163 Split ratio: 15:1 EPC: 50 psi (246 ml/min), Room Temp. Valve:05W-0056V, 0.5ul, The biger size Page 10

11 Impurities in Liquified Ethylene 1, Methane; 2,Ethane; 3, Ethylene; 4, Propane; 5, i-butane; 6, n-butane; 7 n-pentane; 8, n-hexane 22 3 Oven: 35 C, 0 min. 4C/min 120 C 8.75 min. Column: PLOT AL2O3+KCL + DB-1, 30m, 0.53mm,5ul flow ml/min, (7ml/min), 12 psi Split flow: 250.8(154ml/min) Split ratio: 178:1 EPC: 50 psi (170 ml/min), Room Temp. Valve:05W-0056V, 0.5ul The biger one Page 11

12 Traces of Oxygenates in Gas and LPG Type Matrices with Purged Tee Backflush Page 12

13 2 ppm of Oxygenates Standard Page 13

14 Enhanced ASTM D6584 with Traces of Oxygenates- FID 1 Inlet Restrictor Primary Column HP-Innowax (30m x 0.32mm ID x 0.5 um) FID 2 Secondary Column HP-Alumina PLOT M (30 m x 0.53mm ID x 15um) Capillary Flow Technology Deans Switch PCM ASTM D6584 measures trace hydrocarbons uses alumina PLOT column Oxygenates best separated on HP-Innowax column Use Deans switch to combine two methods into one primary column separates oxygenates Deans switch selectively transfers only the hydrocarbons to alumina PLOT HP-Innowax column protects alumina PLOT from damage Page 14

15 Complete Separation of Oxygenates and Hydrocarbons Heart-Cutting 100 ppmv Impurities in Ethylene pa Cut time: min. 5 (methanol) HP-Innowax (19091N-213) pa Min C 1 to C 4 Hydrocarbons Separated on Secondary Column Min Complete separation in one run PLOT Alumina M (19095P-M23) Page 15

16 Excellent Precision for Trace Compounds in Ethylene 20 Runs of Ethylene Spiked with 2 ppmv Peak # Name Avg. (ppmv)* % RSD* 1 methane % 2 ethane % 3 ethylene Balance Balance 4 propane % 5 methanol % 6 propylene % 7 isobutane % 8 n-butane % 9 propadiene % 10 acetylene % 11 tran-2-butene % 12 1-butene % 13 isobutylene % 14 cis-2-butene % 15 1,3-butadiene % 16 methylacetylene % Most RSD s< 2% Page 16

17 2-D GC Analysis of Olefin Feedstocks 2 ppm methanol in Ethylene 2 ppm methanol in Propylene HP-Innowax Alumina M PLOT Page 17

18 Traces of Permanent Gases in Monomers Uses the 10 port low leakage valve The matrix is cut on the packed precolumn Inerts including H2,O2,N2,CO,CH4 are separated on packed column Detection PHID in helium mode Page 18

19 Trace of Permanent Gases in Monomers Page 19

20 PDHID Description and Operating Principle Source for ionization: Low power pulsed DC discharge in helium which generates high energy photons Non-destructive process ( % ionization) Detector response is universal except for Neon Linear Dynamic Range ~ 10 5 MDL in low picogram range INTERCONNECT The PDHID has numerous applications across HPI and environmental industries due to its universal and sensitive response Page 20 PDHID.02

21 Page 21 Analyzer for Traces of Permanent Gases in CO2, Ethylene, Propylene

22 CO,CO2 Traces in Monomers and Process Gases Uses methanizer and FID detection for high sensitivity. May include 4 port venting valve for venting high CH4 amounts. C2+ fraction backflushed from the precolumn to vent Page 22

23 CO,CO2 Traces in Process Gases and Monomers with Venting Valve FLOW SOURCE = #87X 7890 valve system INJECTION PORT DATE : O/N : VALVE COMPARTMENT BLOCK 2 BLOCK 1 Valve 4 Valve 1 File ITEM DETECTOR. H2 301 Aux Aux Aux 5 Out Sample In Loop Vent 4 vent A 210 Valve Options REM : Valve 2 Page 23

24 Traces of CO, CO2,CH4 in Monomers FLOW SOURCE = #87X 7890 valve system INJECTION PORT DATE : O/N : VALVE COMPARTMENT BLOCK 2 BLOCK 1 Valve 4 Valve 1 File ITEM DETECTOR. H2 301 Aux Aux Aux 5 Out Sample In Loop Vent A 210 Valve Options REM : Valve 2 Page 24

25 CO,CO2 at 4.5 ppm and CH4 at 10x higher Concentration Page 25

26 CO,CO2 at 0.45 ppm and CH4 at 10x higher Concentration Page 26

27 Page 27 CO,CO2,CH4 Determinations Repeatibility

28 Page 28 MSD in High Purity Monomer Analysis

29 Improved Response for Sulfur Compounds 1.3 ppm per component in helium Scan amu THT Full Scan! DMS CS 2 tbsh H 2 S COS CH 3 SH EtSH Page 29

30 Improved Response for Sulfur Compounds 1.3 ppm per component in helium Scan amu THT Full Scan! DMS CS 2 tbsh H 2 S COS CH 3 SH EtSH Page 30

31 Improved Response for Sulfur Compounds Sim Mode: 46 ppb per Component In Helium THT 5ppb level of sulfur possible in SIM Excellent peak shape/response DMS CS 2 MeSH EtSH tbsh H 2 S COS Time--> Page 31

32 Improved Response for Sulfur compounds Abundance Sulfur in bulk Propylene (COS fully coeluting with propylene Sim mode: 50 to 1 split 180 ppb each component H 2 S COS Page 32

33 Sulfur Impurities by GCMS in SIM Component Hydrogen Sulfide Carbonyl Sulfide Methyl Mercaptan Ethyl Mercaptan LQL 10 ppb 10 ppb 50 ppb 50 ppb Conc. Range Hydrogen Sulfide ppb Carbonyl Sulfide ppb Methyl Mercaptan ppb Ethyl Mercaptan ppb # of Points Corr. Coeff Hydrogen Sulfide Carbonyl Sulfide Methyl Mercaptan Ethyl Mercaptan Conc. (ppb) Std. Dev % RSD 7.3% 9.3% 2.0% 3.5% Page 33

34 Trace Ethanol in Propylene by GC-MS 3 ppm EtOH Component Methanol Ethanol Isopropanol t-butanol 1-Propanol 1-Butanol MTBE LQL 50 ppb 50 ppb 50 ppb 50 ppb 50 ppb 50 ppb 50 ppb Page 34

35 Other Impurities by GC-MS Component Arsine Phosphine Ammonia Organic Chlorides LQL 50 ppb 50 ppb 2 ppm ~ 20 ppb each Page 35

36 Trace Phosphine in Propylene 3.3 ppm PH 3 Page 36

37 Trace Phosphine in Propylene 3.3 ppm PH 3 Page 37

38 Trace Arsine in Propylene 3.2 ppm AsH 3 Page 38

39 Trace Methylchloride in Propylene 9 ppm MeCl Page 39

40 Summary -GCMSD is a very sensitive and potentially selective GC detector - May be used both in process control and quality control of raw materials and products - Allows positive identification of unknown compounds and confirmation of targets Page 40

Beverage Grade Carbon Dioxide

Beverage Grade Carbon Dioxide Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION The Challenge Carbon dioxide, used in the production of carbonated soft drinks and other beverages,

More information

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Refinery Gas Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Refinery Gas Analysis Reliability Placing refinery gas analyzers in the field for over

More information

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons   Gases C-C Hydrocarbons C-C Paraffins. Methane. Carbon Dioxide. Ethylene. Ethane. Acetylene. Methane (0.9%). Ethane (0.09%). Propane (0.099%). Isobutane (0.09%). Butane (0.09%). n-pentane (0.00%) Column: ft x

More information

Operation and Applications of Differential Flow Modulation

Operation and Applications of Differential Flow Modulation Operation and Applications of Differential Flow Modulation H2 Collection channel Column 1 H2 Column 2 FID Roger L Firor, Ph.D. Agilent Technologies Chemical Analysis Group Wilmington, DE USA Flow Modulator

More information

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels James D. McCurry Senior Scientist Agilent Technologies Wilmington, DE USA Page 1 Application Summary There is a need to measure

More information

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass James D. McCurry, Ph.D. Senior Scientist Agilent Solutions for the Analysis of Ethanol-Based Fuels Derived From Biomass Presented

More information

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces

More information

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices Simon Jones Application Engineer Folsom, CA August 20, 2009 Agenda WCOT vs. PLOT columns OxyPlot A Unique stationary phase

More information

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Based on a New Super Permeable PLOT Column Agilent Select Low Sulfur Johan Kuipers Channel Training Specialist Oct 12 th, 2010 1 October 18,

More information

Agilent and ASTM. Update on Recent Activities. Page 1

Agilent and ASTM. Update on Recent Activities. Page 1 Agilent and ASTM Update on Recent Activities Page 1 ASTM Committees for Refining, Fuels, Petroelum Products ASTM International D2 Petroleum products & lubricants D3 Gas fuels (natural gas) gas fuels D16

More information

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural

More information

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an

More information

performance productivity reliability

performance productivity reliability Solutions that meet your demands for: performance productivity reliability Excellent Choices for Global Hydrocarbon Processing Applications Crude Oil & Natural Gas Natural Gas > Return to Table of Contents

More information

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent

More information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville

More information

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in

More information

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS Agilent Portfolio Luca Godina Technical Marketing Specialist GC-GCMS 1 Summary Introduction Sample Prep Sample Introduction Inlets 7890B LTM CFT Detectors Special Solutions 13/11/12 Tirana Page 2 Agilent

More information

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx 2-D GC/MS and the Deans Switch: Theory and Applications Fred Feyerherm, Agilent Technologies Inc. Houston, Tx Introduction Simplified 2-D GC can be used to accomplish the separation of specific analytes

More information

Application. Gas Chromatography June 1995

Application. Gas Chromatography June 1995 Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee

More information

S-PRO 3200 GC System for Sulfur Analysis

S-PRO 3200 GC System for Sulfur Analysis S-PRO 32 GC System for Sulfur Analysis Superior Selectivity and Sensitivity The ability to detect and measure sulfur contaminants in gases is critically important for efficient operation of industrial

More information

Using the PSD for Backflushing on the Agilent 8890 GC System

Using the PSD for Backflushing on the Agilent 8890 GC System Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped

More information

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer Simple Heart Cutting with Deans Switch and Backflushing with Capillary Flow Technolgy Simon Jones Applications Engineer GC or GC/MS Analysis in Complex Matrices In complex sample matrices, there are often

More information

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices GC Application Chemist March 3rd, 2008 Pittcon 2008, New Orleans, LA Presentation Outline WCOT vs. PLOT columns OxyPLOT A highly

More information

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Now with New Dual Plasma Technology Overview The Agilent Technologies

More information

Gary Stidsen Jaap de Zeeuw

Gary Stidsen Jaap de Zeeuw Market Focus: Petrochemical Gary Stidsen Jaap de Zeeuw Who are our Customers? Petroleum Chemicals Products analyzed in Segment Petroleum Oil, Natural gas, gasoline, kerosene, diesel, Naphtha Hydrocarbons,

More information

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W

More information

GC Method Compliance and Large Valve Oven Application

GC Method Compliance and Large Valve Oven Application GC Method Compliance and Large Valve Oven Application Solution Focused Kelly Beard June 20, 2016 Compliant Methods Compliant Methods What are our options? Analyzers and Analyzer Kits High Volume Well Known

More information

ASTM D 6730 Detailed Hydrocarbon Analysis

ASTM D 6730 Detailed Hydrocarbon Analysis ASTM D 6730 Detailed Hydrocarbon Analysis Jaap de Zeeuw, Jan Pijpelink and Barry Burger Restek Corporation ASTM D 6730-01(2006)e1 Determination of Individual Components in Spark Ignition Engine Fuels as

More information

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System Jim McCurry Roger Firor Agilent Technologies Wilmington, DE Page 1 Scope of the Analyzer Designed for ASTM D7798 For

More information

Antek Gas Chromatography Products: A Guided Tour Through Industry

Antek Gas Chromatography Products: A Guided Tour Through Industry ANTEK GC Application Solutions Feature the Following Detectors: Antek Sulfur and Nitrogen Chemiluminescence, Flame Ionization, Thermal Conductivity, Nitrogen-Phosphorus, Atomic Emission, Halogen Specific,

More information

DANI Transformer Oil Gas Analyzer

DANI Transformer Oil Gas Analyzer DANI Transformer Oil Gas Analyzer APPLICATION NOTE - AN169 Introduction Transformers are electrical devices used for energy transfer by electromagnetic induction between two or more circuits. Large oil

More information

Agilent G2855A Deans Switching System

Agilent G2855A Deans Switching System Agilent G2855A Deans Switching System Installation and Operation Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including

More information

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down

More information

Typical Gas Chromatographic System

Typical Gas Chromatographic System Page 72 Air Hydrogen Carrier Gas Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer Cylinders or Generators Flow Controller Column Recorder/

More information

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE + INGRID CITY GATE STATION INGRID GAS CONTROL CENTER What is? H2 INJECTION is a modular multi-function system based on:, A NEW METHOD OF MANAGING THE

More information

New Specialized GC Columns for the Petroleum Industry -Integrated Particle Trap PLOTs -DB-Sulfur SCD

New Specialized GC Columns for the Petroleum Industry -Integrated Particle Trap PLOTs -DB-Sulfur SCD New Specialized GC Columns for the Petroleum Industry -Integrated Particle Trap PLOTs -DB-Sulfur SCD Daron Decker GC Columns Technical Specialist Agilent Technologies, Inc. October 29, 2013 Porous Layer

More information

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and

More information

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials The Stability of Sulfur s, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials Linda Coyne Cindy Kuhlman Nicole Zovack SKC Inc. Eighty Four, PA 15330 25 January 2011 Publication 1805

More information

Setting up SilFlow for BackFlush in your GC

Setting up SilFlow for BackFlush in your GC Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile

More information

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour

More information

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Shimadzu Customized GC Analyzers GC-2010 Plus Nexis GC-2030 GC-2014 Natural Gas

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc. 850 Centerville

More information

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Technical Overview Trace gas analysis is a challenge in today s world. The ability to analyze lower component

More information

Experience the Difference

Experience the Difference ABB-Totalflow Experience the Difference PGC1000 Process Gas Chromatograph ABB Group October 19, 2011 Slide 1 Process GC Experience ABB introduced the Btu-8000 in 1995 C6+ application suitable for custody

More information

CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN)

CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN) (Cancels T.R.S. No. 48.0.0) CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC LOCAL TARIFF Applying on Intrastate Transportation of PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN) [C] Ethane-Propane Mixture System

More information

Live Crude Oil Volatility

Live Crude Oil Volatility Live Crude Oil Volatility Dan Wispinski : Alberta Innovates Technology Futures Bob Falkiner : Imperial Oil Engineering Services CCQTA/COQA October 31, 2014 Food-Agriculture Environment Health Pipeline

More information

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC Fast GC SPEEDY GC Slide 4 Optimization Goals Primary: Minimize time for the separation of a given number of peaks Secondary: Maximize the number of peaks separated by a given column Slide 5 HOW CAN THESE

More information

Practical Steps in GC Troubleshooting

Practical Steps in GC Troubleshooting Practical Steps in GC Troubleshooting Techniques, Tips, and Tricks Mark Sinnott Application Engineer GC Columns & Supplies Page 1 Everything was just fine and then this happened! How do I go about TROUBLESHOOTING?

More information

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy The world leader in serving science Ultra Fast GC Determination of Total Hydrocarbons (C7-C40) and BTEX in Water and Soils through Direct Resistively Heated capillary columns and Robotic Autosampler. Fausto

More information

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS TURN-KEY ANALYZERS GC SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS BROAD ARRAY BROAD OF ARRAY OF CONFIGURATIONS FOR FOR SPECIAL APPLICATIONS SPECIAL THE THE PERFECT ANSWER TO A SEVERELY TO REGULATED A SEVERELY

More information

CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN)

CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN) (Cancels T.R.S. No. 48.1.0) CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC LOCAL TARIFF Applying on Intrastate Transportation of PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN) Rates in Cents per Barrel of

More information

Catalysts for olefin processes. A range of performance catalysts and absorbents for use across the olefins value chain.

Catalysts for olefin processes. A range of performance catalysts and absorbents for use across the olefins value chain. Catalysts for olefin processes A range of performance catalysts and absorbents for use across the olefins value chain. Information contained in this publication or as otherwise supplied to Users is believed

More information

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities : What Are You Willing To Do? Daron Decker Chromatography Technical Specialist Page 1 Agilent Restricted 3 Options Same Column and Gas Type Try Different/Faster Velocities Same Column, Switch He to H2

More information

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Agilent 6850 Series II Network GC System G2630A Performance Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6850 Series II Network GC

More information

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X GC Best Practices & Troubleshooting Group/Presentation Title Agilent Restricted Month ##, 200X Troubleshooting Tips 1. Isolate the problem. (Blank Runs, Inject Un-retained Compound, Know what it is not)

More information

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract. Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers Application Note Abstract Versa With the rising prices of fossil fuels, more emphasis is being put on renewable resources

More information

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application 7890A/7890B GC Overview October 29, 2014 1 Definitions Carrier Gas Pressurized gas used to transport the sample through the system.

More information

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,

More information

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Cd The Chrom Doctor Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Jaap de Zeeuw, Restek Corporation, Middelburg, The Netherlands. In Part 1 of this series we focused

More information

GC Inlets. An Overview. Simon Jones GC Applications Engineer

GC Inlets. An Overview. Simon Jones GC Applications Engineer GC Inlets An Overview Simon Jones GC Applications Engineer Types of Inlets Purged Packed Split / Splitless Cool On Column Programmable Temperature Vaporization Volatiles Interface Multi Mode Inlet Where

More information

Brushwood-chulha Average (SD) Mixed-chulha Average (SD) Dung-angithi Average (SD) SOAP koh (x ) (cm 3 molec -1 s -1 )

Brushwood-chulha Average (SD) Mixed-chulha Average (SD) Dung-angithi Average (SD) SOAP koh (x ) (cm 3 molec -1 s -1 ) Table S1. Average emission factors and standard deviation of PM2.5 and gas-phase species (g kg -1 dry fuel carbon) for dung-chulha, brushwood-chulha, mixed-chulha, and dungangithi cook fires. Sample size

More information

I SO9001 I SO14001 CE

I SO9001 I SO14001 CE I SO900 I SO400 CE ZHEJIANG FULI ANALYTICAL INSTRUMENT CO., LTD. Address : South Baizhang Road, Economic Development Zone, Wenling City, Taizhou, Z he ji ang Province, P. R. China Zip: 37500 Tel : 0086-576

More information

Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard

Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard Rapid Qualitative GC-TFMS Analysis of a Petroleum Refinery Reformate Standard LEC Corporation; Saint Joseph, Michigan USA Key Words: GC-TFMS, Petrochemical, Deconvolution 1. Introduction Analyses of petroleum

More information

Application Note. Abstract. Authors. Environmental Analysis

Application Note. Abstract. Authors. Environmental Analysis High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research

More information

Replacement Tubes for Gillian Gas Detection Pumps

Replacement Tubes for Gillian Gas Detection Pumps 236SA S 1,1,2-Trichloroethane (10-100 ppm) 235SA S 1,1-Dichloroethane (10-160 ppm) 230SA S 1,2-Dichloroethane (5-50 ppm) 145SA S 1,2-Dichloroethylene (4.2-840 ppm) 194S S 1,3-Dichloropropane (10-500 ppm)

More information

Live Crude Oil Volatility

Live Crude Oil Volatility Live Crude Oil Volatility Dan Wispinski : Alberta Innovates Technology Futures Bob Falkiner : Imperial Oil Engineering Services October 16/15 PerkinElmer Corpus Christi Any and all implied or statutory

More information

HD and HDL Single-Stage Non-Lube Gas Compressors

HD and HDL Single-Stage Non-Lube Gas Compressors COMPRESSORS CB-324 2013/05 Ethylene Ethylene Oxide HCFC s Helium n-heptane n-hexane Hydrogen Hydrogen Chloride Hydrogen Sulfide Isobutane Isobutene Isobutylene Isopentane Methane Methanol Methyl Acetylene

More information

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different

More information

MET-Biodiesel Capillary GC Columns

MET-Biodiesel Capillary GC Columns MET-Biodiesel Capillary GC Columns Product Specifications Product Features & Benefits Chromatograms FAQs Related Products Updated: February 2, 2009 Product Specifications 2 Product Specifications What

More information

Application Note. Authors. Abstract. Energy & Chemicals

Application Note. Authors. Abstract. Energy & Chemicals Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors

More information

Analysis of Petroleum Fractions by ASTM D2887

Analysis of Petroleum Fractions by ASTM D2887 Analysis of Petroleum Fractions by ASTM D2887 Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 2582 Key Words Simulated distillation, D2887, TRACE TR-SimDist Abstract ASTM

More information

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA PET 01 - PETROLEUM ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA GASOLINE RANGE HYDROCARBONS Column Part No.: 054950 BP1, PONA 50 m x 0.15 mm ID Initial Temp.: 30 C, 5 min hold Rate 1: 2 C/min Temp.

More information

Agilent 9000 Intuvo GC Applications. Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D.

Agilent 9000 Intuvo GC Applications. Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D. Agilent 9000 Intuvo GC Applications Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D. Summary of Intuvo Applications by Industry Environmental EPA Method 8270 Semivolatile Organic Compounds

More information

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis Productivity Improvements for Dual Column Applications: USP and Blood Alcohol Analysis Rebecca Veeneman, PhD Applications Chemist Agilent Technologies The GC Usability Gap Usability lags features

More information

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides Application Note Food Testing & Agriculture Authors Limian Zhao and Chin-Kai Meng Agilent Technologies, Inc. 85 Centerville

More information

Phillips 66 Pipeline LLC. Blue Pipeline Natural Gas Liquids Specifications

Phillips 66 Pipeline LLC. Blue Pipeline Natural Gas Liquids Specifications Current Publication Date: 5//208 Previous Publication Date: //208 Revision Notes: Increased Propane RVP maximum from 204 psig to 208 psig. Published 4/0/208 Product Index Product Name Destination(s) NGL

More information

Technical Procedure for Gas Chromatography (GC-FID)

Technical Procedure for Gas Chromatography (GC-FID) Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all

More information

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT PGC1000 Meeting the needs of NGL plants P G C 1 0 0 0 N G L P L A N T P R O D U C T I O N P B/ 1 0 74 3 - E N Measurement made easy PGC1000 NGL PLANT

More information

THC Heated FID 3-300A

THC Heated FID 3-300A Rack Mount/Table Top TVOC Analyzer THC Heated FID 3-300A Space saving 19"/3PU space saving rack mount and table top heated emission analyzer for the continuous determination of the mass concentration of

More information

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Compatible with hydrogen, for 50% faster run times. Improved resolution between oxygenates and hydrocarbons, for more accurate reporting. Individually

More information

Agilent Multimode Inlet for Gas Chromatography

Agilent Multimode Inlet for Gas Chromatography Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything

More information

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation Liner Selection in GC Jaap de Zeeuw Restek Middelburg, The Netherlands What is a liner? A liner is an inert glass tube that is positioned inside the injection port of the GC The sample solution is introduced

More information

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns RESTEK REFINED innovative petrochemical solutions Detailed Hydrocarbon Analysis Featuring Rtx -DHA Columns Individually tested to meet DHA method criteria; guaranteed column-to-column reproducibility.

More information

Colorimetric Gas Detector Tube System US Dollar Price List

Colorimetric Gas Detector Tube System US Dollar Price List Colorimetric Gas Detector Tube System US Dollar Price List Sensidyne, LP - Gas Detector Tube Price List Effective Date: February 12, 2012 Rev. A 010612 Table of Contents Gas Detection Pump Kit & Accessories

More information

GAS CHROMATOGRAPHY LGC-A1 SERIES

GAS CHROMATOGRAPHY LGC-A1 SERIES GAS CHROMATOGRAPHY LGC-A1 SERIES www.labtron.com info@labtron.com Gas Chromatography LGC-A1 Series Gas chromatography LGC-A10 Gas chromatography system LGC-A10 comes with different detectors and each detector

More information

炭化水素 - 直鎖炭化水素 炭化水素 - 炭化水素及びアルコール類

炭化水素 - 直鎖炭化水素 炭化水素 - 炭化水素及びアルコール類 炭化水素 - 直鎖炭化水素 Column : Equity-, 0 m x 0. mm ID, 0. µm Cat. No. : 0-U Column : Equity-, 0 m x 0. mm ID, 0. µm Cat. No. : 09-U Oven : 0 ( min), /min to ( min) Inj.: Track oven Det. : FID, Carrier gas: Helium,.

More information

Molecular Sieves Application Guide for the Natural Gas Industry Molecular Sieve Molecular Sieve Recommendations

Molecular Sieves Application Guide for the Natural Gas Industry Molecular Sieve Molecular Sieve Recommendations Application Guide for the Natural Gas Industry Natural Gas / DG Natural Gas / EPG to less than 0.1 ppm(v) prior to liquefaction or Natural Gas liquids Extraction. to less than 0.1 ppm(v) while minimizing

More information

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR 6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR A15836 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use

More information

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Bill Wilson and Chin-Kai Meng Agilent Technologies, Inc. 2850 Centerville Road Wilmington,

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board/ACLASS 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Eurofins Toxics, Inc. 180 Blue Ravine

More information

Forensic Blood Alcohol Determination with the Intuvo 9000 GC

Forensic Blood Alcohol Determination with the Intuvo 9000 GC Forensic Blood Alcohol Determination with the Intuvo 9000 GC Rebecca Veeneman, Ph.D Applications Chemist The GC Usability Gap Usability lags features and performance Over the years, GC features and performance

More information

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS) SPECIFICATION Bench top triple quadrupole Mass performance Chromatography (GC-MS/MS) 1. Scope These specifications describe the requirements for a bench top triple quadrupole mass spectrometry system coupled

More information

Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges

Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges Alexandria Pavkovich Jason Thomas Trent Sprenkle Outline Background EPA Method Requirements Background

More information

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application Authors Steven M. Wilbur and Emmett Soffey Agilent Technologies 338 146th Place SE Bellevue,

More information

Collection & Analysis of Reduced Sulfur Compounds in Air

Collection & Analysis of Reduced Sulfur Compounds in Air Collection & Analysis of Reduced Sulfur Compounds in Air Roy Smith M.Sc., MBA, C.Chem. Air Quality Manager, ALS Environmental Waterloo Laboratory 1 Reduced Sulfur Compounds (RSCs) Offensive low odour thresholds

More information

Oil & Gas Application Notebook

Oil & Gas Application Notebook Natural Gas Oil & Gas Application Notebook AOX in Waste Chromatography, Mass Spectrometry, Molecular Spectroscopy, Natural Gas Oil and Gas Production. The Global Challenge. Whether or not the oil and gas

More information

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System Application Note Authors Frank David Research Institute for Chromatography, Pres.

More information

Web: Phone: (302) , Fax: (302)

Web:   Phone: (302) , Fax: (302) Zhenghua Zack Ji, PhD Zoe Wang, MS General Separation Technologies, Inc. 625 Dawson Drive, Newark, DE 19713, USA Email: info@gs-tek.com Web: www.gs-tek.com Phone: (302) 533-5646, Fax: (302) 737-4547 min

More information

Professional Chemical Analyzer Service / BigDipper TechnoChem Institute, Beijing China. Hand held Single Gas Analyzer H-BD5gas

Professional Chemical Analyzer Service / BigDipper TechnoChem Institute, Beijing China. Hand held Single Gas Analyzer H-BD5gas Professional Chemical Analyzer Service / BigDipper TechnoChem Institute, Beijing China Hand held Single Gas Analyzer H-BD5gas Gas Analyzer Special Application Configuration for Industrial and Research

More information