1 I SO900 I SO400 CE ZHEJIANG FULI ANALYTICAL INSTRUMENT CO., LTD. Address : South Baizhang Road, Economic Development Zone, Wenling City, Taizhou, Z he ji ang Province, P. R. China Zip: Tel : Fax: Mobile: / forrest3wang@gmail.com/wangjh@cnfuli.com.cn Web : www. cnfuli. com. cn GC970 General sales and support conditions of distributorship Gas chromatograph Fuli welcomes any new partner to expand business. However the distributorship is on non-exclusive basis, we will offer exclusive distributorship after evaluating the performance of non-exclusive distributor. Distributor responsibility. To have excellent knowledge of GC, HPLC, AAS and UV/VIS spectrophotometer.. To have engineer capable of installing, training and after-sales service. 3. Training in FULI is provided if distributors require. Training term can be discussed individually. 4. To have own website to present FULI products very well and Link to FULI website. 5. To provide obliging customer pre/after sales care and active search of new customers. FULI responsibility. Supply all technical details, catalogue, picture, manual, trouble-shooting, etc.. Onsite training and remote technical support via or phone. 3. Life-time components/spare parts supply. ZHEJIANG FULI ANALYTICAL INSTRUMENTS CO.,LTD.

2 GC970 Gas Chromatograph Gas chromatograph AFC characteristic AFC: split/splitless mode, carrier gas can fulfill constant-pressure, constant-flow, constant-speed, programmable-temperature-rise, programmable-flow-rise and programmable-speed-rise to reduce sample decomposition and discrimination while increase separation and shorten analysis time. EPC/ AFC fulfill digitalization and automatization, only need input column parameters, EPC/AFC can set best flow of column and show digitally. EPC/AFC can fulfill gas leaking self-diagnosis and cut off flow&gas source and alarm at the same time. Traditional GC(Column 40 ) Analysis time 43min GC970 (Column 40 ) with programmable pressure-rise Analysis time 7min Instrument feature 3.4min.6min PCM control module much precise with independent-development AFC system; 8-channel high-accuracy temperature control system and 8-channel outside events to fulfill counter-control ; Every gas circuit can achieve constant-pressure, constant-flow, constant-speed, programmable-temperature-rise, programmable-flow-rise and programmable-speed-rise; Unlimited valve events to fulfill accurate switching of multi-valve; Outside power & voltage checking system, over-heating protection system and flow monitoring system to make it intellectualized. Vacuum fluorescent display with english/chinese changeable; Multi-function keyboard can set complicated parameters and store 6 chromatography method; FID and FPD can provide reminder for auto ignite and turn-off, TCD with overflow/cut-off protection; Excellent FID wide-range to enhance linear range; Multi-valve and multi-column switch system to make sure complicated analysis at one times injection; PCB system shielding function to reduce interference; Carrier gas saving mode available to reduce cost; Autosampler, headspace and thermal desorption can be incorporated; Clarity workstation can fulfill 3Q certification to meet GMP/GLP standard. Traditional GC constant-flow mode Analysis time 3.4min Carrier gas saving mode: After injeciton, can proceed low split flow mode automatically to reduce carrier gas significantly. GC970 with programmable pressure-rise Analysis time 7min 0/03

3 Multi-valve and multi-column switch Adopting AFP pneumatic valve, can setup 3-valve-4-column and 4-valve-5-column switch system to fully analyze only at one times in petrochemical, coal gas, trace CH in ethylene and trace CO and CO in ethylene. Clarity workstation is applicable Multi-channel and multi-user universal workstation to control all parameter Can collect signal from 4 detectors via RS3 or USB Basic parameter: max sample-collecting peak process quantity/integral μv*s Batch processing makes machine control, auto sampling sequence collecting, auto integral correction much easier Fully support FDA-CFR PART, SST AND IQ/OQ Powerful post-treatment facilitate chromatography comparing, re-correction and data input&output. Multi-valve and multi-column flow diagram Hayesep Q(Separate CO, CO and SO )m 5A( block H, O and N)m FL970 workstation feature Fully counter-control to set all parameter in workstation Easy operational Multi-channel signal sampling, multi outside events control 3 PCM ml Hayesep Q pre-column TCD Release Port 3 off CAP 3 S/SL Air block Capillary Pre-column FID 5UL Port off Port off Out Cap. AlO3 04/05

4 FL090 autosampler for 970 Can incorporate flash-evaporation and high pressure liquid injection Flash-evaporation injection for gas-liquid mixture, high pressure valve injection for liquid. Big displayer with double -tower automatic injection; Tray vial quantity: 6 or 50; Injection volume: 0.-00uL; Sampling accuracy: ± 0. 0uL; Injection needle: 5, 0, 50, 00uL; Injection repeatability: <0.5% Column oven dimension: mm=4.L; Temp. control range: RT+5 ~450 (0. increment); Programming temp.-ramp speed:0-0 /min; Programming temp.-ramp : any step; Fast cool down: 350~00 3.5minutes; Temp. accuracy: 0.. Performance introduction INSTRUMENTS PERFORMANCE IS INTRODUCED PTV sample injection With multiple accumulated injection and solvent release, increase temperature program-rise to achieve trace analysis. Excellent qualitative repeateability Retention time RSD 0.05% Wide split ratio setting range; Max capillary split ratio: 4500:; Packed injection, capillary injection, flash-evaporation injection, PTV injection and liquid injection are available; Easy consumables changeover Excellent wide range FID design, no ceiling limit for solvent peak; - Limit of detection can be 3*0 g/s; Ignition recognition, H protection, anti-ponding; Solvent no tailing peak /07

5 5 Excellent quantitative repeatability 5 Peak area RSD 0.8% Typical application GC970 is suitable but no limited to below application: food safety, 9 9 environmental protection, energy( Petroleum refining), medicine industry and etc Food safety Chinse white wine Excellent wide-range design makes no ceiling limit of solvent peak 300ppm FID standard sample Peak at 30000, no ceiling limit Column: LZP950 for wine DEHP(Di-(-ethylhexyl)phthalate) Column: HP-5 cap /09

6 Environmental protection 00ppb organochlorine in pesticide residue TVOC: ppm Benzene mixture standard Detector: ECD Column: HP Injection mode: thermal desorption Column: GS-Innowax cap Peak sequence: α-bhc, β-bhc, γ-bhc, δ-bhc, op-dde, pp-ddd, op-ddt, pp-ddt ppb organophosphorus pesticide residue Sulfide in air Detector: FPD Column: DB-35 Peak sequence: DDVP, methamidophos, acephate, omethoate, dimethoate, parathionmethyl, fenitrothion, parathion, quinalphos, tiguron, triazophos Detector: TCD Inlet: Packed Column: Hayesep Q Peak sequence: COS, CS, SO, Methyl Mercaptan, Ethyl Mercaptan Complicated organochlorine 0.ug/L CCl4, 0.ug/LCHCl3 in water Detector: ECD Column: HP Detector: ECD Column: DM- Peak sequence: CHCl3, CCl /

7 Energy Petroleum refining +TCD Injector: gas/capillary 4-valve-5-column Gas control module: 4sets Valve injection Inorganic gas peak sequence: H, CO, O, N, CO Column: Hayesep Q packed, 5A packed, ALO3capillary, DB- capillary Workstation: FL 970 Hydrocarbon peak sequence: CH4, CH6, CH4, C3H6, C3H8, cyclopropane, CH, iso-butane, propadiene, n-butane, trans--butene, n-butylene, isobutene, cis--butene, isopentane, n-pentane, allylene,,3- butadiene, -methyl--butene, trans--pentene, -pentene, cis--pentene, Hexane Dimethyl ether in LNG Injection mode: Gas valve injection Column: PLOT Q cap. Peak sequence: CH4, CH, propene, propane, methylal, Dimethyl ether, n-butene, cis -butene, isoamylene, methyl alcohol, n-pentane inorganic gas Hydrocarbon Medicine Organic acid Distillation simulation Column: HP- cap. Aromatic compounds Column: DB-FFAP Peak sequence: acetic acid, propionic acid, butyrate, valeric acid, sovaleric acid, caproic acid, heptylic acid, octanoic acid, n-nonanoic acid, lactic acid, - Hydroxy--Methylbutyric Acid Cresol isomer Column: Innowax cap. Peak sequence: Benzene, Toluene, Ethane, P-xylene, M- xylene, P-Ethyltoluene, M-Ethyltoluene, S-Butybenzene, Diethylbenzene, O-diethylbenzene Column: specialized for cresol Peak sequence: o-cresol, p-cresol, m-cresol /3

8 Organic solvent: Detector: FPD Column: DB-64 cap. Peak sequence: methyl alcohol, ethanol, acetone+ isopropanol, acetonitrile, dichloromethane, chloroform, isobutanol, CCl4, Benzene, n-heptane, isoamylol, pyridine, toluene, n-amyl alcohol, ethylbenzene, p-xylene, n-hexanol, o- xylene FULI PLANT GLIMPSE ABOUT Fuli VOCS nd-level solution: Detector: FPD Column: PC-VOCOL Peak sequence: methanol, ethanol, isopropanol, acetone, methyl acetate, n- butyl alcohol, butanone, ethyl acetate, acetic acid isopropyl ester, benzene, - Methoxy--propanol, propyl acetat, 4- methyl--pentanone, -Ethoxy-- propanol, toluene, n-butyl acetate, ethylbenzene, o-xylene, styrene ppb thiophene in Benzene: Detector: FPD Column: HP-Innowax /5

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Refinery Gas Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Refinery Gas Analysis Reliability Placing refinery gas analyzers in the field for over

More information

Agilent Multimode Inlet for Gas Chromatography

Agilent Multimode Inlet for Gas Chromatography Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything

More information

C2, C3, C4 Monomer Analysis

C2, C3, C4 Monomer Analysis C2, C3, C4 Monomer Analysis Malgorzata Sierocinska Agilent Technologies Waldbronn Page 1 Why Analyze Monomers? To Insure Consistent Production of High Quality Polymer Protect against food contamination

More information

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons   Gases C-C Hydrocarbons C-C Paraffins. Methane. Carbon Dioxide. Ethylene. Ethane. Acetylene. Methane (0.9%). Ethane (0.09%). Propane (0.099%). Isobutane (0.09%). Butane (0.09%). n-pentane (0.00%) Column: ft x

More information

Beverage Grade Carbon Dioxide

Beverage Grade Carbon Dioxide Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION The Challenge Carbon dioxide, used in the production of carbonated soft drinks and other beverages,

More information

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in

More information

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels James D. McCurry Senior Scientist Agilent Technologies Wilmington, DE USA Page 1 Application Summary There is a need to measure

More information

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and

More information

GAS CHROMATOGRAPHY LGC-A1 SERIES

GAS CHROMATOGRAPHY LGC-A1 SERIES GAS CHROMATOGRAPHY LGC-A1 SERIES www.labtron.com info@labtron.com Gas Chromatography LGC-A1 Series Gas chromatography LGC-A10 Gas chromatography system LGC-A10 comes with different detectors and each detector

More information

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials The Stability of Sulfur s, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials Linda Coyne Cindy Kuhlman Nicole Zovack SKC Inc. Eighty Four, PA 15330 25 January 2011 Publication 1805

More information

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural

More information

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces

More information

Operation and Applications of Differential Flow Modulation

Operation and Applications of Differential Flow Modulation Operation and Applications of Differential Flow Modulation H2 Collection channel Column 1 H2 Column 2 FID Roger L Firor, Ph.D. Agilent Technologies Chemical Analysis Group Wilmington, DE USA Flow Modulator

More information

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis Productivity Improvements for Dual Column Applications: USP and Blood Alcohol Analysis Rebecca Veeneman, PhD Applications Chemist Agilent Technologies The GC Usability Gap Usability lags features

More information

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an

More information

Workshop Automated Sample Preparation and Introduction for the Analysis of Unknowns. Ray Perkins Anatune Ltd

Workshop Automated Sample Preparation and Introduction for the Analysis of Unknowns. Ray Perkins Anatune Ltd Workshop Automated Sample Preparation and Introduction for the Analysis of Unknowns Ray Perkins Anatune Ltd HP 5970 GC/MS (1984) Agilent 7200 GCqTOF MultiFlex GCqTOF GC-QTOF When analysing for unknowns,

More information

Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard

Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard Rapid Qualitative GC-TFMS Analysis of a Petroleum Refinery Reformate Standard LEC Corporation; Saint Joseph, Michigan USA Key Words: GC-TFMS, Petrochemical, Deconvolution 1. Introduction Analyses of petroleum

More information

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy The world leader in serving science Ultra Fast GC Determination of Total Hydrocarbons (C7-C40) and BTEX in Water and Soils through Direct Resistively Heated capillary columns and Robotic Autosampler. Fausto

More information

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS TURN-KEY ANALYZERS GC SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS BROAD ARRAY BROAD OF ARRAY OF CONFIGURATIONS FOR FOR SPECIAL APPLICATIONS SPECIAL THE THE PERFECT ANSWER TO A SEVERELY TO REGULATED A SEVERELY

More information

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS Agilent Portfolio Luca Godina Technical Marketing Specialist GC-GCMS 1 Summary Introduction Sample Prep Sample Introduction Inlets 7890B LTM CFT Detectors Special Solutions 13/11/12 Tirana Page 2 Agilent

More information

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass James D. McCurry, Ph.D. Senior Scientist Agilent Solutions for the Analysis of Ethanol-Based Fuels Derived From Biomass Presented

More information

Brushwood-chulha Average (SD) Mixed-chulha Average (SD) Dung-angithi Average (SD) SOAP koh (x ) (cm 3 molec -1 s -1 )

Brushwood-chulha Average (SD) Mixed-chulha Average (SD) Dung-angithi Average (SD) SOAP koh (x ) (cm 3 molec -1 s -1 ) Table S1. Average emission factors and standard deviation of PM2.5 and gas-phase species (g kg -1 dry fuel carbon) for dung-chulha, brushwood-chulha, mixed-chulha, and dungangithi cook fires. Sample size

More information

GC Method Compliance and Large Valve Oven Application

GC Method Compliance and Large Valve Oven Application GC Method Compliance and Large Valve Oven Application Solution Focused Kelly Beard June 20, 2016 Compliant Methods Compliant Methods What are our options? Analyzers and Analyzer Kits High Volume Well Known

More information

Reliable. Efficient. Economical. Distillation Technology ENGINEERING - EQUIPMENT - TURNKEY SYSTEMS

Reliable. Efficient. Economical. Distillation Technology ENGINEERING - EQUIPMENT - TURNKEY SYSTEMS TM Economical Efficient Reliable Distillation Technology ENGINEERING - EQUIPMENT - TURNKEY SYSTEMS DISTILLATION TECHNOLOGY Distillation is by far the most important separation process in the petroleum

More information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville

More information

Antek Gas Chromatography Products: A Guided Tour Through Industry

Antek Gas Chromatography Products: A Guided Tour Through Industry ANTEK GC Application Solutions Feature the Following Detectors: Antek Sulfur and Nitrogen Chemiluminescence, Flame Ionization, Thermal Conductivity, Nitrogen-Phosphorus, Atomic Emission, Halogen Specific,

More information

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices GC Application Chemist March 3rd, 2008 Pittcon 2008, New Orleans, LA Presentation Outline WCOT vs. PLOT columns OxyPLOT A highly

More information

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices Simon Jones Application Engineer Folsom, CA August 20, 2009 Agenda WCOT vs. PLOT columns OxyPlot A Unique stationary phase

More information

CP-3800 GAS CHROMATOGRAPH

CP-3800 GAS CHROMATOGRAPH CP-3800 GAS CHROMATOGRAPH P/N 03-914689-00 Rev 4 TABLE OF CONTENTS I. GC OPERATION... 2 Overview... 2 Instrument Setup... 3 Building a Method... 4 Automation... 5 Activating the GC Method... 5 Making a

More information

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Technical Overview Trace gas analysis is a challenge in today s world. The ability to analyze lower component

More information

Agilent and ASTM. Update on Recent Activities. Page 1

Agilent and ASTM. Update on Recent Activities. Page 1 Agilent and ASTM Update on Recent Activities Page 1 ASTM Committees for Refining, Fuels, Petroelum Products ASTM International D2 Petroleum products & lubricants D3 Gas fuels (natural gas) gas fuels D16

More information

Application. Gas Chromatography June 1995

Application. Gas Chromatography June 1995 Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee

More information

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA PET 01 - PETROLEUM ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA GASOLINE RANGE HYDROCARBONS Column Part No.: 054950 BP1, PONA 50 m x 0.15 mm ID Initial Temp.: 30 C, 5 min hold Rate 1: 2 C/min Temp.

More information

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour

More information

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application 7890A/7890B GC Overview October 29, 2014 1 Definitions Carrier Gas Pressurized gas used to transport the sample through the system.

More information

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph-mass spectrometer (GC-MS). 2.0 Scope

More information

Technical Procedure for Gas Chromatography (GC-FID)

Technical Procedure for Gas Chromatography (GC-FID) Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all

More information

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co.,Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai

More information

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in

More information

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS FUELS AND EFFECTS ON ENGINE EMISSIONS The Lecture Contains: Transport Fuels and Quality Requirements Fuel Hydrocarbons and Other Components Paraffins Cycloparaffins Olefins Aromatics Alcohols and Ethers

More information

Bright prospects Solvents for spectroscopy Uvasol

Bright prospects Solvents for spectroscopy Uvasol Bright prospects Solvents for spectroscopy Uvasol EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Simply the best UV/VIS and infrared spectroscopy are reliable and accurate methods

More information

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Now with New Dual Plasma Technology Overview The Agilent Technologies

More information

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors Model 8610C Gas Chromatograph Mounts up to Six Detectors and Five Injectors Ambient to 400 C Temperature Programmable Column Ovens Dimensions: 19 wide x 13.5 high x 14.5 deep Implement virtually any EPA

More information

GC Inlets. An Overview. Simon Jones GC Applications Engineer

GC Inlets. An Overview. Simon Jones GC Applications Engineer GC Inlets An Overview Simon Jones GC Applications Engineer Types of Inlets Purged Packed Split / Splitless Cool On Column Programmable Temperature Vaporization Volatiles Interface Multi Mode Inlet Where

More information

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC Fast GC SPEEDY GC Slide 4 Optimization Goals Primary: Minimize time for the separation of a given number of peaks Secondary: Maximize the number of peaks separated by a given column Slide 5 HOW CAN THESE

More information

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Bill Wilson and Chin-Kai Meng Agilent Technologies, Inc. 2850 Centerville Road Wilmington,

More information

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that EPA National Vehicle and Fuel Emissions Laboratory

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

TABLE S-1 Emission source and source profile categorization in the PRD region

TABLE S-1 Emission source and source profile categorization in the PRD region Support Information TABLE S-1 Emission source and source profile categorization in the PRD region Emission Source a Source Profile b Power Plant combustion Coal burning-boiler Industry combustion Coal

More information

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities : What Are You Willing To Do? Daron Decker Chromatography Technical Specialist Page 1 Agilent Restricted 3 Options Same Column and Gas Type Try Different/Faster Velocities Same Column, Switch He to H2

More information

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID. Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID. Dedicated PiPNA + FAME For (Bio-)Diesel and Jet Fuels Robust System, Easy to use No Cryogenic coolant Required Keywords:

More information

New Specialized GC Columns for the Petroleum Industry -Integrated Particle Trap PLOTs -DB-Sulfur SCD

New Specialized GC Columns for the Petroleum Industry -Integrated Particle Trap PLOTs -DB-Sulfur SCD New Specialized GC Columns for the Petroleum Industry -Integrated Particle Trap PLOTs -DB-Sulfur SCD Daron Decker GC Columns Technical Specialist Agilent Technologies, Inc. October 29, 2013 Porous Layer

More information

炭化水素 - 直鎖炭化水素 炭化水素 - 炭化水素及びアルコール類

炭化水素 - 直鎖炭化水素 炭化水素 - 炭化水素及びアルコール類 炭化水素 - 直鎖炭化水素 Column : Equity-, 0 m x 0. mm ID, 0. µm Cat. No. : 0-U Column : Equity-, 0 m x 0. mm ID, 0. µm Cat. No. : 09-U Oven : 0 ( min), /min to ( min) Inj.: Track oven Det. : FID, Carrier gas: Helium,.

More information

Application Note. Abstract. Authors. Environmental Analysis

Application Note. Abstract. Authors. Environmental Analysis High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research

More information

Forensic Blood Alcohol Determination with the Intuvo 9000 GC

Forensic Blood Alcohol Determination with the Intuvo 9000 GC Forensic Blood Alcohol Determination with the Intuvo 9000 GC Rebecca Veeneman, Ph.D Applications Chemist The GC Usability Gap Usability lags features and performance Over the years, GC features and performance

More information

High-Temperature Simulated Distillation System Based on the 6890N GC Application

High-Temperature Simulated Distillation System Based on the 6890N GC Application High-Temperature Simulated Distillation System Based on the 6890N GC Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co., Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai

More information

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent

More information

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Abstract High Temperature Simulated Distillation (High Temp SIMDIS) is one of the most frequently used techniques to determine

More information

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Application Note Hydrocarbon Processing Authors ChunXiao Wang Agilent Technologies

More information

Replacement Tubes for Gillian Gas Detection Pumps

Replacement Tubes for Gillian Gas Detection Pumps 236SA S 1,1,2-Trichloroethane (10-100 ppm) 235SA S 1,1-Dichloroethane (10-160 ppm) 230SA S 1,2-Dichloroethane (5-50 ppm) 145SA S 1,2-Dichloroethylene (4.2-840 ppm) 194S S 1,3-Dichloropropane (10-500 ppm)

More information

ASTM D 6730 Detailed Hydrocarbon Analysis

ASTM D 6730 Detailed Hydrocarbon Analysis ASTM D 6730 Detailed Hydrocarbon Analysis Jaap de Zeeuw, Jan Pijpelink and Barry Burger Restek Corporation ASTM D 6730-01(2006)e1 Determination of Individual Components in Spark Ignition Engine Fuels as

More information

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Agilent 6850 Series II Network GC System G2630A Performance Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6850 Series II Network GC

More information

HSNO Class Flammable Liquids

HSNO Class Flammable Liquids Safe Method of Use 10 HSNO Class 3.1 - Flammable Liquids Purpose: This Safe Method of Use applies to principal investigators (PIs), sector managers, designated laboratory person (DLPs), technical staff

More information

Table C 15. TAC Emissions Summary and Ambient Air Impact Concentrations. FCA Mack Avenue Assembly Plant Update February 2019

Table C 15. TAC Emissions Summary and Ambient Air Impact Concentrations. FCA Mack Avenue Assembly Plant Update February 2019 Paint Sealer Oven Prime Obs BC1 Obs BC2 Obs CC1 Obs CC2 Obs Concentrator RTO Rapid Reprocess Spot Prime General Building Ventilation 2 Prime Oven 1 Prime Oven 2 (lb/hr) (lb/hr) (lb/hr) (lb/hr) (lb/hr)

More information

LIABLE RESULTS AND RELIABLE RESULTS AND EXCEPTIONAL REPRODUCIBILITY

LIABLE RESULTS AND RELIABLE RESULTS AND EXCEPTIONAL REPRODUCIBILITY STATIC HEADSPACE SAMPLER SHS HISTORICALLY HISTORICALLY THE THE BEST BUST A ROBUST AND FLEXIBLE SYSTEM TO SYSTEM MEET COMPLEX TO AND VERSATILE MEET NEEDS COMPLEX AND LIABLE RESULTS AND RELIABLE RESULTS

More information

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System Application Note Authors Frank David Research Institute for Chromatography, Pres.

More information

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Shimadzu Customized GC Analyzers GC-2010 Plus Nexis GC-2030 GC-2014 Natural Gas

More information

S-PRO 3200 GC System for Sulfur Analysis

S-PRO 3200 GC System for Sulfur Analysis S-PRO 32 GC System for Sulfur Analysis Superior Selectivity and Sensitivity The ability to detect and measure sulfur contaminants in gases is critically important for efficient operation of industrial

More information

Gas Chromatography www.labtron.com info@labtron.com LGC-A10 - ually controls the temperature of the system. This gas chromatography comes with packed column injectors, split/split less injectors, capillary

More information

Agilent 7693A Automated Liquid Sampler

Agilent 7693A Automated Liquid Sampler Agilent 7693A Automated Liquid Sampler Specifications Overview The Agilent 7693A is a state-of-the-art sample handling and injection system that provides the highest levels of precision and reliability

More information

4001 Transesterification of castor oil to ricinoleic acid methyl ester

4001 Transesterification of castor oil to ricinoleic acid methyl ester 4001 Transesterification of castor oil to ricinoleic acid methyl ester castor oil + MeH Na-methylate H Me CH 4 (32.0) C 19 H 36 3 (312.5) Classification Reaction types and substance classes reaction of

More information

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different

More information

Thermal Conversion of Fossil and Renewable Feedstocks

Thermal Conversion of Fossil and Renewable Feedstocks Thermal Conversion of Fossil and Renewable Feedstocks Steven P. Pyl Advisors prof. dr. Marie-Françoise Reyniers prof. dr. ir. Guy B. Marin Laboratory for Chemical Technology The Need for Detail Fundamental

More information

performance productivity reliability

performance productivity reliability Solutions that meet your demands for: performance productivity reliability Excellent Choices for Global Hydrocarbon Processing Applications Crude Oil & Natural Gas Natural Gas > Return to Table of Contents

More information

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009 SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009 DCG PARTNERSHIP 1, LTD. 4170 A South Main Pearland, TX 77581 Louis D Agostaro Phone: 281-648-1894 Ext. 201 REFERENCE MATERIAL PRODUCER Valid To: November 30,

More information

Paramount Chemical Guide

Paramount Chemical Guide Paramount Chemical Guide Use this table to evaluate additional chemicals that you may decide to use after the Paramount has been set up for its intended application. Following the table is a chart key

More information

FILTRATION SYSTEMS CARBOX PHARMACEUTICAL HOODS ACTIVATED CHARCOAL FILTERS

FILTRATION SYSTEMS CARBOX PHARMACEUTICAL HOODS ACTIVATED CHARCOAL FILTERS CARBOX FILTRATION SYSTEMS 47 Filtration systems for the treatment of harmful fumes resulting from chemical processings. INDEX PHARMACEUTICAL HOODS 49 ACTIVATED CHARCOAL FILTERS 53 48 CAP-FARM 60 Aspirated

More information

Using the PSD for Backflushing on the Agilent 8890 GC System

Using the PSD for Backflushing on the Agilent 8890 GC System Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped

More information

Analytical Test Report

Analytical Test Report Sample Name: Vanilla Haze Laboratory ID: 04141607 Batch ID: EVH41416 Client: Cascadia Herbals Tamper bags: na Science First. Analytical Test Report 11119 SE Division St Date Received: 4/14/2016 Cannabinoids

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board/ACLASS 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Eurofins Toxics, Inc. 180 Blue Ravine

More information

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Based on a New Super Permeable PLOT Column Agilent Select Low Sulfur Johan Kuipers Channel Training Specialist Oct 12 th, 2010 1 October 18,

More information

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE + INGRID CITY GATE STATION INGRID GAS CONTROL CENTER What is? H2 INJECTION is a modular multi-function system based on:, A NEW METHOD OF MANAGING THE

More information

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down

More information

Filtration efficiency: 99% or more HEPO2element

Filtration efficiency: 99% or more HEPO2element High Precision Filter for Liquids Series Filtration efficiency: 99% or more HEPO2element Filtration accuracy: 2, 4, 6 or 13 µm (Filtration efficiency 99%) Membrane element Filtration accuracy: 0.2 or 0.4

More information

DANI Transformer Oil Gas Analyzer

DANI Transformer Oil Gas Analyzer DANI Transformer Oil Gas Analyzer APPLICATION NOTE - AN169 Introduction Transformers are electrical devices used for energy transfer by electromagnetic induction between two or more circuits. Large oil

More information

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides Application Note Food Testing & Agriculture Authors Limian Zhao and Chin-Kai Meng Agilent Technologies, Inc. 85 Centerville

More information

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,

More information

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract. Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers Application Note Abstract Versa With the rising prices of fossil fuels, more emphasis is being put on renewable resources

More information

Agilent Distributor News

Agilent Distributor News Agilent Distributor News Volume 7, Issue 1 Alert your customers! New Agilent GC and LC column selection guides will make their work easier. Column Selection: Simpler, Faster, Better Key Selling Points

More information

Experience the Difference

Experience the Difference ABB-Totalflow Experience the Difference PGC1000 Process Gas Chromatograph ABB Group October 19, 2011 Slide 1 Process GC Experience ABB introduced the Btu-8000 in 1995 C6+ application suitable for custody

More information

Agilent 7693A Automated Liquid Sampler

Agilent 7693A Automated Liquid Sampler IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7693A Automated Liquid Sampler

More information

TANK LINING RESISTANCE GUIDE I-19

TANK LINING RESISTANCE GUIDE I-19 INTRODUCTION Wattyl s Tank Lining Resistance Guide provides a list of chemicals and their suitability in contact with Epinamel TL710, Galvit ES600 and Galvit ES510. GUIDE TO DATA R Recommended cargo R,

More information

Web: Phone: (302) , Fax: (302)

Web:   Phone: (302) , Fax: (302) Zhenghua Zack Ji, PhD Zoe Wang, MS General Separation Technologies, Inc. 625 Dawson Drive, Newark, DE 19713, USA Email: info@gs-tek.com Web: www.gs-tek.com Phone: (302) 533-5646, Fax: (302) 737-4547 min

More information

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System Jim McCurry Roger Firor Agilent Technologies Wilmington, DE Page 1 Scope of the Analyzer Designed for ASTM D7798 For

More information

ANTEK APPLICATED Turn-Key GC solutions

ANTEK APPLICATED Turn-Key GC solutions ANTEK APPLICATED Turn-Key GC solutions The ANTEK advantage Antek patents chemiluminescent nitrogen detection apparatus & method Antek introduces first total nitrogen chemiluminescence analyzer Antek opens

More information

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Compatible with hydrogen, for 50% faster run times. Improved resolution between oxygenates and hydrocarbons, for more accurate reporting. Individually

More information

Setting up SilFlow for BackFlush in your GC

Setting up SilFlow for BackFlush in your GC Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile

More information

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology Electronic Noses An electronic nose produces a recognizable response based

More information

Application Note. Authors. Abstract. Energy & Chemicals

Application Note. Authors. Abstract. Energy & Chemicals Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors

More information