Agilent and ASTM. Update on Recent Activities. Page 1

Size: px
Start display at page:

Download "Agilent and ASTM. Update on Recent Activities. Page 1"

Transcription

1 Agilent and ASTM Update on Recent Activities Page 1

2 ASTM Committees for Refining, Fuels, Petroelum Products ASTM International D2 Petroleum products & lubricants D3 Gas fuels (natural gas) gas fuels D16 Aromatic Hydrocarbons & related chemicals D32 Catalysts properties & performance Global, non-profit, consensus organization Develop test methods, product specifications, practices, terminology, guides and classifications 4 main areas of focus: materials, products, systems and services Over 130 subcommittees cover specific areas - petroleum, chemicals, environmental, safety, etc. 10,000+ standards published each year in 73 volumes 32,000 members in 100+ countries Page 2

3 Agilent Involvement with ASTM Agilent (HP) and ASTM relationship since the 1960s Currently 6 Agilent scientists actively participate in ASTM D2 and D16 Participation includes developing methods, introducing new technology, round robins Some important methods Agilent (HP) helped develop - D4815: oxygenates in gasoline - D5580: aromatics in gasoline - D2887 and D3710 SIMDIS for diesel and gasoline - D7423 trace oxygenates in C2 to C5 hydrocarbons steams Some current methods under development with ASTM: - 2-D Capillary GC method for oxygenated additives in gasoline (D4815 replacement) - Aromatics and methanol in high methanol fuels using heart-cutting 2-D GC - New inlet conditions (MMI) for biodiesel (D6584) - Alternative carrier gases for D5580 (aromatics in gasoline), D4815 (oxygenates in gasoline), D3606 (benzene/toluene in gasoline), D2887 (SIMDIS for middle distillates) Page 3

4 New ASTM Developments for Gas Phase Analyses New methanol/gasoline blends - methanol easily made from new sources of natural gas (fracking technology) - GC method measures up to 85% methanol in gasoline blends 2-D GC method based on Agilent Deans switch application (pub # N) Recycled motor oils - recovering used motor oil saves petroleum resources - must meet specifications for fuel and glycol contamination - New D7593 method uses GC with back flush to measure gasoline and diesel contamination Agilent helped write GC conditions using 7890 Capillary Flow Technology back flush - GC Headspace method proposed to measure ethylene glycol in oil D4291 will remain the primary method to measure ethylene glycol in oil D4291 uses liquid-liquid extraction followed by GC-FID analysis 4

5 New ASTM Developments for Gas Phase Analyses D7845 approved to measure chemical contaminants in marine fuel oil - fuel contaminated with phenols, styrenes, pinenes, alcohols - method developed on Agilent 5977 GC/MS system with CFT back flush - Agilent will participate in 2014 round robin - a new GC-QQQ method under development to measure FAMEs, fatty acids, bis-phenols and glycerides contaminants in marine fuel Gasoline SIMDIS method D3710 using packed columns is withdrawn - D7096 is the new method using capillary columns D7798 approved as new Ultrafast SMDIS method - D2887 equivalent - developed using Agilent LTM column heating technology - Agilent participated in round robin 5

6 Examples of Agilent s Current Work with ASTM Gasoline and Biofuels - Capillary GC version of D3606 under development Improved separation of benzene from ethanol and butanol gasoline blends Uses fluidic switch (Deans switch) with backflush - Investigation of a new capillary D4815 method improved oxygenate separation from olefins - 3-in-1 ASTM Gasoline Solution Using 7890 Large Valve Oven Configures D3606, D5580 and D4815 on a single instrument Diesel Fuels and Biodiesel - D7798 Ultrafast SIMDIS using direct column heating technology Agilent LTM - Improvements to ASTM D6584 Biodiesel method Better performance using Agilent Multimode Inlet Alternative GC carrier gas - Response to helium shortages and price increases - Reviewing current ASTM GC methods for capability with nitrogen or hydrogen SIMDIS and D4815 methods currently under ballot for nitrogen or hydrogen carrier gas use - New Agilent 7890 Helium Conservation Module - New Agilent 7890 Hydrogen Sensor

7 New D3606 Capillary GC Configuration - Improved Separation of Benzene Jim McCurry Agilent Technologies Wilmington, DE USA 7

8 CFT Splitter at Sample Injection Use FID1 signal to determine time toluene elutes from pre-column. This is the backflush time. P = psig S/S Inlet EPC UDFS restrictor 0.58m x 0.1mm 2.9 ml/min 2.7 ml/min FID 1 FID 2 Pre-column: HP1 30m x 0.25mm x 0.50um Analytical column: Innowax 60m x 0.32mm x 1.00um Aux EPC P = psig

9 Toluene Elution Time on Pre-Column Faster & easier back flush set-up with CFT and UDFS restrictor Pre-column Restrictor FID1 i-c 8 toluene ethanol MIBK 4.22 min back flush time benzene min

10 CFT Splitter at Back Flush Time (4.22 min) P = psig S/S Inlet EPC UDFS restrictor 0.58m x 0.1mm -1.2 ml/min 2.0 ml/min FID 1 FID 2 Pre-column: HP1 30m x 0.25mm x 0.50um Analytical column: Innowax 60m x 0.32mm x 1.00um Aux EPC P = psig

11 Flow Modifications to Resolve Toluene/i-Butanol initial Temp Initial hold ramp 1 Temp 2 Hold 2 Until i-buoh elutes ramp 2 Final temp Final hold 75 o C 8min 5 o C/min 80 o C 5min 10 o C/min 95 o C until n-butanol elutes Backflush time (until toluene elutes) 4.23 analytical Flow rate at time 0 analyltical Flow rate 0.1min after BF time Pre-column flow rate at time ml/min 2.0 ml/min 2.7 ml/min

12 Commercial Pump Gasoline Sample ethanol toluene Better separation of ethanol from benzene compared to D3606 packed column configuration MIBK benzene

13 Comparison of Helium and Nitrogen Carrier Gas Operation for ASTM D4815 Jim McCurry Agilent Technologies Wilmington, DE USA

14 D4815 Configuration Primary flow S/S EPC split/splitless inlet TCEP column HP-1 capillary column Secondary flow Aux EPC variable restrictor FID TCD

15 Helium Conservation Module Seamlessly integrated onto 7890 GC hardware and software To Inlet EPCs Purge Built on 5 th generation EPC Fully controlled by Agilent data systems Flow channel inside the bridge block N 2 in He in Purge channel prevents cross contamination of gases Precise pressure control between tank and GC Switch between gases within 15-30min for most detectors Std. Aux EPC

16 Helium Conservation Module Helium Operation Mode 1 ml/min (out) AUX EPC 1 Nitrogen 0 psig AUX EPC 3 Purge 10 psig AUX EPC 2 Helium 80 psig (< 0.2 ml/min) N 2 Bridge Block To GC Inlet EPC Helium ON at 80 psig, Nitrogen OFF

17 Helium Conservation Modules Nitrogen Operation Mode 1.0 ml/min (out) AUX EPC 1 Nitrogen 80 psig AUX EPC 3 Purge Vent 10 psig AUX EPC 2 Helium 0 psig (< 0.2 ml/min) He Bridge Block 24.2 ml/min N 2 Helium OFF, Nitrogen ON at 80 psig To GC Inlet EPC

18 D4815 Helium and Nitrogen Carrier Gas Operating Conditions Helium GC Conditions Nitrogen Col1: TCEP Micropacked 5.0 ml/min (17.8 psi) 5.0 ml/min (16.7 psi) Col2: PDMS Capillary 3.1 ml/min (14.7 psi) 3.1 ml/min (13.8 psi) Split Flow 70 ml/min 70 ml/min TCEP Backflush Time 0.24 min min TCEP Reset Time 0.84 min min Valve Oven Temp 60 o C 60 o C Column Oven Temp 60 o C 60 o C

19 D4815 Helium and Nitrogen Carrier Gas Calibration of Oxygenates Helium Carrier Gas Nitrogen Carrier Gas Compound corr (>= 0.99) slope y-int y-int test (<0.1) corr (>= 0.99) slope y-int y-int test (<0.1) MeOH EtOH i-proh t-buoh n-proh MTBE BuOH DIPE i-buoh ETBE t-amyl-oh n-buoh

20 D4815 Helium and Nitrogen Carrier Gas MTBE in Gasoline MTBE Helium Carrier Gas Nitrogen Carrier Gas Min.

21 D4815 Helium and Nitrogen Carrier Gas Ethanol in Gasoline Helium Carrier Gas Ethanol Nitrogen Carrier Gas Min.

22 D4815 Helium and Nitrogen Carrier Gas Results from 3 Gasoline Samples Gas1 wt% MTBE Gas2 wt% Ethanol Gas3 wt% Ethanol Helium Nitrogen Helium Nitrogen Helium Nitrogen run run Avg r (calc) r (spec)

23 Inlet Comparison of ASTM D6584: COC vs. Temperature Programmed Split Jim McCurry Agilent Technologies February 19,

24 Inlets With Temperature Program Capability Inlet temp programming provides flexibility for injection volume, analysis of thermally labile samples and minimizing inlet discrimination for high molecular Wt components Greater sensitivity through large volume injections Reduce sample preparation steps, resulting in enhanced productivity Solvent venting and Backflush are possible using auxiliary pressure source and CFT device

25 Multimode Inlet (MMI) Extremely flexible Split/splitless Multiple injection COC Simulation Can eliminate needle discrimination Minimal thermal stress on sample Large volume capability

26 Standard Techniques Cold split injection Cold splitless injection (COC simulation) Hot split injection Solvent venting Stationary phase/solvent venting for focusing

27 Multimode Inlet Features Hardware Temperature range of -160C to 450C 15C/sec Septum/Liner Easily Exchangeable Injection Modes: Hot S/SL, Cold S/SL, all in pulsed mode, solvent vent mode, residue removal mode Support for single stroke injections from 0.1 ml to 250 ml EPC Compatible with Packed Liners Compatible with 7890A, 5975C, 7683, CTC Combi PAL Software Ten temperature ramps Solution for solvent vent timing Fully integrated into ChemStation, MSD ChemStation, EZChrom, MassHunter

28 New Multimode Inlet Improvements Turn-top easy liner exchange Standard 11mm septa Air plus CO2, N2 cryogenic cooling No leaks at liner Standard liner dimensions Standard column nut

29 MMI Conditions Used For ASTM D6584 Column: Agilent Select Biodiesel 15 m x 0.32 mm, 0.10 μm (p/n CP9079) Carrier: Helium 5.6 ml/min constant flow Oven: 50 C (hold 1 min), then to 180 C at 15 C/min, then to 230 C at 7 C/min, then to 380 C at 30 C/min (hold 10 min) Injection: MMI Cold-Splitless, Initial temp 88 C for 0.1min, then to 350 C at 250 C/min (hold 1 min) Purge time 1.00min., Purge Flow 9.6ml/min. Detector: FID at 380 C Sampler: Agilent 7693, 1μL volume injection

30 Soy B100 Run With MMI

31 Comparison of Single Lab Precision (r) For MMI and COC Inlet wt% Glycerol wt% Monoglycerides wt% Diglycerides wt% Triglycerides wt% Total Glycerin COC MMI COC MMI COC MMI COC MMI COC MMI Run Run Average r (calc) r (spec) MMI provides same results as COC MMI provides better precision

32 Summary Agilent and ASTM have a long and successful history for developing new solutions for HPI measurements Agilent continues to provide strong support and leadership within ASTM community Agilent works with ASTM members to understand new measurement technologies and incorporate them into the latest methods 32

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels James D. McCurry Senior Scientist Agilent Technologies Wilmington, DE USA Page 1 Application Summary There is a need to measure

More information

Application. Gas Chromatography June 1995

Application. Gas Chromatography June 1995 Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee

More information

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass James D. McCurry, Ph.D. Senior Scientist Agilent Solutions for the Analysis of Ethanol-Based Fuels Derived From Biomass Presented

More information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville

More information

GC Inlets. An Overview. Simon Jones GC Applications Engineer

GC Inlets. An Overview. Simon Jones GC Applications Engineer GC Inlets An Overview Simon Jones GC Applications Engineer Types of Inlets Purged Packed Split / Splitless Cool On Column Programmable Temperature Vaporization Volatiles Interface Multi Mode Inlet Where

More information

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System Jim McCurry Roger Firor Agilent Technologies Wilmington, DE Page 1 Scope of the Analyzer Designed for ASTM D7798 For

More information

GC Method Compliance and Large Valve Oven Application

GC Method Compliance and Large Valve Oven Application GC Method Compliance and Large Valve Oven Application Solution Focused Kelly Beard June 20, 2016 Compliant Methods Compliant Methods What are our options? Analyzers and Analyzer Kits High Volume Well Known

More information

Comprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels

Comprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels Paper # 160-6 Comprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels Elise K. Libby, John V. Seeley, Stacy K. Seeley Oakland University, Rochester, MI, USA James D. McCurry

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent

More information

C2, C3, C4 Monomer Analysis

C2, C3, C4 Monomer Analysis C2, C3, C4 Monomer Analysis Malgorzata Sierocinska Agilent Technologies Waldbronn Page 1 Why Analyze Monomers? To Insure Consistent Production of High Quality Polymer Protect against food contamination

More information

Agilent Multimode Inlet for Gas Chromatography

Agilent Multimode Inlet for Gas Chromatography Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything

More information

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices Simon Jones Application Engineer Folsom, CA August 20, 2009 Agenda WCOT vs. PLOT columns OxyPlot A Unique stationary phase

More information

Using the PSD for Backflushing on the Agilent 8890 GC System

Using the PSD for Backflushing on the Agilent 8890 GC System Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped

More information

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down

More information

Operation and Applications of Differential Flow Modulation

Operation and Applications of Differential Flow Modulation Operation and Applications of Differential Flow Modulation H2 Collection channel Column 1 H2 Column 2 FID Roger L Firor, Ph.D. Agilent Technologies Chemical Analysis Group Wilmington, DE USA Flow Modulator

More information

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W

More information

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer Simple Heart Cutting with Deans Switch and Backflushing with Capillary Flow Technolgy Simon Jones Applications Engineer GC or GC/MS Analysis in Complex Matrices In complex sample matrices, there are often

More information

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR 6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR A15836 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use

More information

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011 Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc.

More information

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN1413:211 Method Application Note Author James D. McCurry, Ph.D. Agilent Technologies Abstract

More information

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC Fast GC SPEEDY GC Slide 4 Optimization Goals Primary: Minimize time for the separation of a given number of peaks Secondary: Maximize the number of peaks separated by a given column Slide 5 HOW CAN THESE

More information

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,

More information

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction Analysis of Glycerin and Glycerides in Biodiesel (B1) Using ASTM D68 and EN11 Application HPI/Petrochemicals/Polymers Author James D. McCurry Agilent Technologies, Inc. 8 Centerville Road Wilmington, DE

More information

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application 7890A/7890B GC Overview October 29, 2014 1 Definitions Carrier Gas Pressurized gas used to transport the sample through the system.

More information

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc. 850 Centerville

More information

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices GC Application Chemist March 3rd, 2008 Pittcon 2008, New Orleans, LA Presentation Outline WCOT vs. PLOT columns OxyPLOT A highly

More information

Application Note. Author. Introduction. Energy and Fuels

Application Note. Author. Introduction. Energy and Fuels Analysis of Free and Total Glycerol in B-100 Biodiesel Methyl Esters Using Agilent Select Biodiesel for Glycerides Application Note Energy and Fuels Author John Oostdijk Agilent Technologies, Inc. Introduction

More information

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co.,Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai

More information

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour

More information

ASTM D 6730 Detailed Hydrocarbon Analysis

ASTM D 6730 Detailed Hydrocarbon Analysis ASTM D 6730 Detailed Hydrocarbon Analysis Jaap de Zeeuw, Jan Pijpelink and Barry Burger Restek Corporation ASTM D 6730-01(2006)e1 Determination of Individual Components in Spark Ignition Engine Fuels as

More information

Setting up SilFlow for BackFlush in your GC

Setting up SilFlow for BackFlush in your GC Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile

More information

Application Note. Abstract. Authors. Environmental Analysis

Application Note. Abstract. Authors. Environmental Analysis High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research

More information

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx 2-D GC/MS and the Deans Switch: Theory and Applications Fred Feyerherm, Agilent Technologies Inc. Houston, Tx Introduction Simplified 2-D GC can be used to accomplish the separation of specific analytes

More information

MET-Biodiesel Capillary GC Columns

MET-Biodiesel Capillary GC Columns MET-Biodiesel Capillary GC Columns Product Specifications Product Features & Benefits Chromatograms FAQs Related Products Updated: February 2, 2009 Product Specifications 2 Product Specifications What

More information

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in

More information

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Bill Wilson and Chin-Kai Meng Agilent Technologies, Inc. 2850 Centerville Road Wilmington,

More information

Agilent G2855A Deans Switching System

Agilent G2855A Deans Switching System Agilent G2855A Deans Switching System Installation and Operation Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including

More information

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract. Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers Application Note Abstract Versa With the rising prices of fossil fuels, more emphasis is being put on renewable resources

More information

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS TURN-KEY ANALYZERS GC SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS BROAD ARRAY BROAD OF ARRAY OF CONFIGURATIONS FOR FOR SPECIAL APPLICATIONS SPECIAL THE THE PERFECT ANSWER TO A SEVERELY TO REGULATED A SEVERELY

More information

Method Development for Capillary GC Systems. Slide 1

Method Development for Capillary GC Systems. Slide 1 Method Development for Capillary GC Systems Slide 1 AREAS TO OPTIMIZE Injector Carrier gas Column temperature Slide 2 COMMON INJECTOR MODES Vaporization Injection Modes Megabore Direct Split Splitless

More information

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Agilent 6850 Series II Network GC System G2630A Performance Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6850 Series II Network GC

More information

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Cd The Chrom Doctor Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Jaap de Zeeuw, Restek Corporation, Middelburg, The Netherlands. In Part 1 of this series we focused

More information

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System Application Note Authors Frank David Research Institute for Chromatography, Pres.

More information

Determination of Free and Total Glycerin in B100 Biodiesel

Determination of Free and Total Glycerin in B100 Biodiesel Page 1 of 5 Page 1 of 5 Return to Web Version Determination of Free and Total Glycerin in B100 Biodiesel By: Michael D. Buchanan, Katherine K. Stenerson, and Vicki Yearick, Reporter US Vol 27.1 techservice@sial.com

More information

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis Productivity Improvements for Dual Column Applications: USP and Blood Alcohol Analysis Rebecca Veeneman, PhD Applications Chemist Agilent Technologies The GC Usability Gap Usability lags features

More information

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584 Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN 14105 and ASTM D6584 Introduction With today s increasing concern for the environment and the depletion of fossil

More information

Technical Procedure for Gas Chromatography (GC-FID)

Technical Procedure for Gas Chromatography (GC-FID) Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all

More information

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different

More information

High-Temperature Simulated Distillation System Based on the 6890N GC Application

High-Temperature Simulated Distillation System Based on the 6890N GC Application High-Temperature Simulated Distillation System Based on the 6890N GC Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co., Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai

More information

Typical Gas Chromatographic System

Typical Gas Chromatographic System Page 72 Air Hydrogen Carrier Gas Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer Cylinders or Generators Flow Controller Column Recorder/

More information

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105 Application Note: 10215 Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105 Fausto Munari, Daniela Cavagnino, Andrea Cadoppi, Thermo Fisher Scientific, Milan,

More information

Antek Gas Chromatography Products: A Guided Tour Through Industry

Antek Gas Chromatography Products: A Guided Tour Through Industry ANTEK GC Application Solutions Feature the Following Detectors: Antek Sulfur and Nitrogen Chemiluminescence, Flame Ionization, Thermal Conductivity, Nitrogen-Phosphorus, Atomic Emission, Halogen Specific,

More information

DANI Transformer Oil Gas Analyzer

DANI Transformer Oil Gas Analyzer DANI Transformer Oil Gas Analyzer APPLICATION NOTE - AN169 Introduction Transformers are electrical devices used for energy transfer by electromagnetic induction between two or more circuits. Large oil

More information

Going Green: The Analysis of BioFuels

Going Green: The Analysis of BioFuels Going Green: The Analysis of BioFuels Miles S Snow Sr. Product Specialist PerkinElmer LAS miles.snow@perkinelmer.com What is Biodiesel?? Biodiesel is a clean burning alternative fuel, produced from domestic,

More information

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS Agilent Portfolio Luca Godina Technical Marketing Specialist GC-GCMS 1 Summary Introduction Sample Prep Sample Introduction Inlets 7890B LTM CFT Detectors Special Solutions 13/11/12 Tirana Page 2 Agilent

More information

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy The world leader in serving science Ultra Fast GC Determination of Total Hydrocarbons (C7-C40) and BTEX in Water and Soils through Direct Resistively Heated capillary columns and Robotic Autosampler. Fausto

More information

Application Note. Authors. Abstract

Application Note. Authors. Abstract Comparison of Temperature Programmable Split/Splitless and Cool On-column Inlets for the Determination of Glycerol and Glycerides in Biodiesel by Gas Chromatography with Flame Ionization Detection* Application

More information

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in

More information

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Compatible with hydrogen, for 50% faster run times. Improved resolution between oxygenates and hydrocarbons, for more accurate reporting. Individually

More information

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA PET 01 - PETROLEUM ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA GASOLINE RANGE HYDROCARBONS Column Part No.: 054950 BP1, PONA 50 m x 0.15 mm ID Initial Temp.: 30 C, 5 min hold Rate 1: 2 C/min Temp.

More information

Forensic Blood Alcohol Determination with the Intuvo 9000 GC

Forensic Blood Alcohol Determination with the Intuvo 9000 GC Forensic Blood Alcohol Determination with the Intuvo 9000 GC Rebecca Veeneman, Ph.D Applications Chemist The GC Usability Gap Usability lags features and performance Over the years, GC features and performance

More information

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and

More information

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph-mass spectrometer (GC-MS). 2.0 Scope

More information

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X GC Best Practices & Troubleshooting Group/Presentation Title Agilent Restricted Month ##, 200X Troubleshooting Tips 1. Isolate the problem. (Blank Runs, Inject Un-retained Compound, Know what it is not)

More information

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces

More information

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Simulated Distillation Analyzers, Software, Standards, Consumables, Training Simulated Distillation Analyzers, Software, Standards, Consumables, Training www.separationsystems.com Offering the Fullest Range of Optimized Solutions Simulated distillation (SimDis) has been used to

More information

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Refinery Gas Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Refinery Gas Analysis Reliability Placing refinery gas analyzers in the field for over

More information

Application Note. Authors. Abstract. Energy & Chemicals

Application Note. Authors. Abstract. Energy & Chemicals Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors

More information

Agilent 9000 Intuvo GC Applications. Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D.

Agilent 9000 Intuvo GC Applications. Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D. Agilent 9000 Intuvo GC Applications Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D. Summary of Intuvo Applications by Industry Environmental EPA Method 8270 Semivolatile Organic Compounds

More information

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides Application Note Food Testing & Agriculture Authors Limian Zhao and Chin-Kai Meng Agilent Technologies, Inc. 85 Centerville

More information

Installing a Purged Packed Inlet

Installing a Purged Packed Inlet Installing a Purged Packed Inlet Agilent 6850 Gas Chromatograph This kit contains: Accessory G2651A Description Purged packed column inlet system 1 Top block insulation 1 Bottom block insulation 1 Insulation

More information

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Shimadzu Customized GC Analyzers GC-2010 Plus Nexis GC-2030 GC-2014 Natural Gas

More information

performance productivity reliability

performance productivity reliability Solutions that meet your demands for: performance productivity reliability Excellent Choices for Global Hydrocarbon Processing Applications Crude Oil & Natural Gas Natural Gas > Return to Table of Contents

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that EPA National Vehicle and Fuel Emissions Laboratory

More information

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors Model 8610C Gas Chromatograph Mounts up to Six Detectors and Five Injectors Ambient to 400 C Temperature Programmable Column Ovens Dimensions: 19 wide x 13.5 high x 14.5 deep Implement virtually any EPA

More information

Installing the 6850 Direct Valve Column Connector Kit

Installing the 6850 Direct Valve Column Connector Kit Use this kit to bypass the inlet and connect your 6850 gas or liquid sampling valve directly to a column. To use this kit, your 6850 GC must have a purged packed inlet. This kit contains: Installing the

More information

GC Analysis of PCBs in Fish Oil by Direct Injection Without Any Sample Cleanup. Philip L. Wylie, Ph.D. Sr. Applications Chemist Agilent Technologies

GC Analysis of PCBs in Fish Oil by Direct Injection Without Any Sample Cleanup. Philip L. Wylie, Ph.D. Sr. Applications Chemist Agilent Technologies GC Analysis of PCBs in Fish Oil by Direct Injection Without Any Sample Cleanup Philip L. Wylie, Ph.D. Sr. Applications Chemist Agilent Technologies Pittsburgh Conference, 2008 Paper 1120-1 Tuesday, 8:30

More information

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems Application Note Hydrocarbons Authors Michael Woodman Agilent Technologies, Inc. Chemical Analysis Solutions 2850

More information

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns RESTEK REFINED innovative petrochemical solutions Detailed Hydrocarbon Analysis Featuring Rtx -DHA Columns Individually tested to meet DHA method criteria; guaranteed column-to-column reproducibility.

More information

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory For the Agilent Intuvo 9000 Gas Chromatograph Installation Instructions Parts Supplied Table 1 Parts supplied with an Agilent G3969A

More information

Beverage Grade Carbon Dioxide

Beverage Grade Carbon Dioxide Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION The Challenge Carbon dioxide, used in the production of carbonated soft drinks and other beverages,

More information

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities : What Are You Willing To Do? Daron Decker Chromatography Technical Specialist Page 1 Agilent Restricted 3 Options Same Column and Gas Type Try Different/Faster Velocities Same Column, Switch He to H2

More information

Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID

Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID Introduction P Gorst-Allman (LECO Africa Pty. Ltd) and B-J de Vos (NMISA). The analysis

More information

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software Install a capillary column in the oven of the SRI GC. The ASTM method suggests a 12 meter.32mm id narrow-bore column coupled with a 2.5 meter guard column but permits the use of any column which exhibits

More information

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades High Speed PONA Analysis For Detailed Hydrocarbon Analysis Extended (DHAX) Using Hydrogen Carrier Gas For The Determination of Individual Components In Spark Ignition Fuels Barry L. Burger, Neil Johansen,

More information

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an

More information

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation Liner Selection in GC Jaap de Zeeuw Restek Middelburg, The Netherlands What is a liner? A liner is an inert glass tube that is positioned inside the injection port of the GC The sample solution is introduced

More information

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems Meeting the Requirements of ASTM D 6591-06 ( IP548/06 ) with Agilent 1200 LC Systems M.Woodman, Chemical Analysis Solutions Unit, Wilmington, Delaware, USA M.Sierocinska, European Field Support Centre,

More information

High-Performing Restek PAL SPME Fibers

High-Performing Restek PAL SPME Fibers Restek Sample Handling High-Performing Restek PAL SPME Fibers Suitable for a wide range of analyte chemistries and sample matrices. Reliable performance meets or exceeds other brands. Robust aluminum hub

More information

Agilent Multimode Inlet

Agilent Multimode Inlet Agilent Multimode Inlet Large Volume Injection Tutorial Agilent Technologies Notices Agilent Technologies, Inc. 2009 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained and certified

More information

Refinery and Natural Gas Analysis

Refinery and Natural Gas Analysis Refinery and Natural Gas Analysis 2 ENSURE MORE ACCURATE AND EFFICIENT ANALYSIS TAKE CONTROL OF YOUR OPERATIONS Oil refineries and natural gas producers around the world require their lab operations to

More information

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals Phenomenex Exclusive! Easy Seals Inlet Base Seals Guaranteed fit for Agilent 5000, 6000 and 7000 Series GCs The Easy Seals Gold Standard No Strained Hands No Troublesome Washers or Adaptors Continuing

More information

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Large Volume Injection of Polycyclic Aromatic Hydrocarbons JSB is an authorised partner of Large Volume Injection of Polycyclic Aromatic Hydrocarbons Application Note - Environmental #113 Author Anne Jurek Applications Chemist EST Analytical Cincinnati, OH Abstract

More information

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural

More information

Techniques for Improving the Reproducibility of GC Analysis

Techniques for Improving the Reproducibility of GC Analysis Techniques for Improving the Reproducibility of GC Analysis Primary Areas of Concern Sample Auto-Injector Inlet Column Detector Sample Extract Handling and Care It is critical that the sample extract be

More information

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard 7890 GC Standard Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained

More information

Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS

Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS Application Environmental Authors Wei Luan and Chuanhong Tu Agilent Technologies (Shanghai) Co., Ltd. 412 Ying

More information

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Application Note Hydrocarbon Processing Authors ChunXiao Wang Agilent Technologies

More information