1 Agilent and ASTM Update on Recent Activities Page 1
2 ASTM Committees for Refining, Fuels, Petroelum Products ASTM International D2 Petroleum products & lubricants D3 Gas fuels (natural gas) gas fuels D16 Aromatic Hydrocarbons & related chemicals D32 Catalysts properties & performance Global, non-profit, consensus organization Develop test methods, product specifications, practices, terminology, guides and classifications 4 main areas of focus: materials, products, systems and services Over 130 subcommittees cover specific areas - petroleum, chemicals, environmental, safety, etc. 10,000+ standards published each year in 73 volumes 32,000 members in 100+ countries Page 2
3 Agilent Involvement with ASTM Agilent (HP) and ASTM relationship since the 1960s Currently 6 Agilent scientists actively participate in ASTM D2 and D16 Participation includes developing methods, introducing new technology, round robins Some important methods Agilent (HP) helped develop - D4815: oxygenates in gasoline - D5580: aromatics in gasoline - D2887 and D3710 SIMDIS for diesel and gasoline - D7423 trace oxygenates in C2 to C5 hydrocarbons steams Some current methods under development with ASTM: - 2-D Capillary GC method for oxygenated additives in gasoline (D4815 replacement) - Aromatics and methanol in high methanol fuels using heart-cutting 2-D GC - New inlet conditions (MMI) for biodiesel (D6584) - Alternative carrier gases for D5580 (aromatics in gasoline), D4815 (oxygenates in gasoline), D3606 (benzene/toluene in gasoline), D2887 (SIMDIS for middle distillates) Page 3
4 New ASTM Developments for Gas Phase Analyses New methanol/gasoline blends - methanol easily made from new sources of natural gas (fracking technology) - GC method measures up to 85% methanol in gasoline blends 2-D GC method based on Agilent Deans switch application (pub # N) Recycled motor oils - recovering used motor oil saves petroleum resources - must meet specifications for fuel and glycol contamination - New D7593 method uses GC with back flush to measure gasoline and diesel contamination Agilent helped write GC conditions using 7890 Capillary Flow Technology back flush - GC Headspace method proposed to measure ethylene glycol in oil D4291 will remain the primary method to measure ethylene glycol in oil D4291 uses liquid-liquid extraction followed by GC-FID analysis 4
5 New ASTM Developments for Gas Phase Analyses D7845 approved to measure chemical contaminants in marine fuel oil - fuel contaminated with phenols, styrenes, pinenes, alcohols - method developed on Agilent 5977 GC/MS system with CFT back flush - Agilent will participate in 2014 round robin - a new GC-QQQ method under development to measure FAMEs, fatty acids, bis-phenols and glycerides contaminants in marine fuel Gasoline SIMDIS method D3710 using packed columns is withdrawn - D7096 is the new method using capillary columns D7798 approved as new Ultrafast SMDIS method - D2887 equivalent - developed using Agilent LTM column heating technology - Agilent participated in round robin 5
6 Examples of Agilent s Current Work with ASTM Gasoline and Biofuels - Capillary GC version of D3606 under development Improved separation of benzene from ethanol and butanol gasoline blends Uses fluidic switch (Deans switch) with backflush - Investigation of a new capillary D4815 method improved oxygenate separation from olefins - 3-in-1 ASTM Gasoline Solution Using 7890 Large Valve Oven Configures D3606, D5580 and D4815 on a single instrument Diesel Fuels and Biodiesel - D7798 Ultrafast SIMDIS using direct column heating technology Agilent LTM - Improvements to ASTM D6584 Biodiesel method Better performance using Agilent Multimode Inlet Alternative GC carrier gas - Response to helium shortages and price increases - Reviewing current ASTM GC methods for capability with nitrogen or hydrogen SIMDIS and D4815 methods currently under ballot for nitrogen or hydrogen carrier gas use - New Agilent 7890 Helium Conservation Module - New Agilent 7890 Hydrogen Sensor
7 New D3606 Capillary GC Configuration - Improved Separation of Benzene Jim McCurry Agilent Technologies Wilmington, DE USA 7
8 CFT Splitter at Sample Injection Use FID1 signal to determine time toluene elutes from pre-column. This is the backflush time. P = psig S/S Inlet EPC UDFS restrictor 0.58m x 0.1mm 2.9 ml/min 2.7 ml/min FID 1 FID 2 Pre-column: HP1 30m x 0.25mm x 0.50um Analytical column: Innowax 60m x 0.32mm x 1.00um Aux EPC P = psig
9 Toluene Elution Time on Pre-Column Faster & easier back flush set-up with CFT and UDFS restrictor Pre-column Restrictor FID1 i-c 8 toluene ethanol MIBK 4.22 min back flush time benzene min
10 CFT Splitter at Back Flush Time (4.22 min) P = psig S/S Inlet EPC UDFS restrictor 0.58m x 0.1mm -1.2 ml/min 2.0 ml/min FID 1 FID 2 Pre-column: HP1 30m x 0.25mm x 0.50um Analytical column: Innowax 60m x 0.32mm x 1.00um Aux EPC P = psig
11 Flow Modifications to Resolve Toluene/i-Butanol initial Temp Initial hold ramp 1 Temp 2 Hold 2 Until i-buoh elutes ramp 2 Final temp Final hold 75 o C 8min 5 o C/min 80 o C 5min 10 o C/min 95 o C until n-butanol elutes Backflush time (until toluene elutes) 4.23 analytical Flow rate at time 0 analyltical Flow rate 0.1min after BF time Pre-column flow rate at time ml/min 2.0 ml/min 2.7 ml/min
12 Commercial Pump Gasoline Sample ethanol toluene Better separation of ethanol from benzene compared to D3606 packed column configuration MIBK benzene
13 Comparison of Helium and Nitrogen Carrier Gas Operation for ASTM D4815 Jim McCurry Agilent Technologies Wilmington, DE USA
14 D4815 Configuration Primary flow S/S EPC split/splitless inlet TCEP column HP-1 capillary column Secondary flow Aux EPC variable restrictor FID TCD
15 Helium Conservation Module Seamlessly integrated onto 7890 GC hardware and software To Inlet EPCs Purge Built on 5 th generation EPC Fully controlled by Agilent data systems Flow channel inside the bridge block N 2 in He in Purge channel prevents cross contamination of gases Precise pressure control between tank and GC Switch between gases within 15-30min for most detectors Std. Aux EPC
16 Helium Conservation Module Helium Operation Mode 1 ml/min (out) AUX EPC 1 Nitrogen 0 psig AUX EPC 3 Purge 10 psig AUX EPC 2 Helium 80 psig (< 0.2 ml/min) N 2 Bridge Block To GC Inlet EPC Helium ON at 80 psig, Nitrogen OFF
17 Helium Conservation Modules Nitrogen Operation Mode 1.0 ml/min (out) AUX EPC 1 Nitrogen 80 psig AUX EPC 3 Purge Vent 10 psig AUX EPC 2 Helium 0 psig (< 0.2 ml/min) He Bridge Block 24.2 ml/min N 2 Helium OFF, Nitrogen ON at 80 psig To GC Inlet EPC
18 D4815 Helium and Nitrogen Carrier Gas Operating Conditions Helium GC Conditions Nitrogen Col1: TCEP Micropacked 5.0 ml/min (17.8 psi) 5.0 ml/min (16.7 psi) Col2: PDMS Capillary 3.1 ml/min (14.7 psi) 3.1 ml/min (13.8 psi) Split Flow 70 ml/min 70 ml/min TCEP Backflush Time 0.24 min min TCEP Reset Time 0.84 min min Valve Oven Temp 60 o C 60 o C Column Oven Temp 60 o C 60 o C
19 D4815 Helium and Nitrogen Carrier Gas Calibration of Oxygenates Helium Carrier Gas Nitrogen Carrier Gas Compound corr (>= 0.99) slope y-int y-int test (<0.1) corr (>= 0.99) slope y-int y-int test (<0.1) MeOH EtOH i-proh t-buoh n-proh MTBE BuOH DIPE i-buoh ETBE t-amyl-oh n-buoh
20 D4815 Helium and Nitrogen Carrier Gas MTBE in Gasoline MTBE Helium Carrier Gas Nitrogen Carrier Gas Min.
21 D4815 Helium and Nitrogen Carrier Gas Ethanol in Gasoline Helium Carrier Gas Ethanol Nitrogen Carrier Gas Min.
22 D4815 Helium and Nitrogen Carrier Gas Results from 3 Gasoline Samples Gas1 wt% MTBE Gas2 wt% Ethanol Gas3 wt% Ethanol Helium Nitrogen Helium Nitrogen Helium Nitrogen run run Avg r (calc) r (spec)
23 Inlet Comparison of ASTM D6584: COC vs. Temperature Programmed Split Jim McCurry Agilent Technologies February 19,
24 Inlets With Temperature Program Capability Inlet temp programming provides flexibility for injection volume, analysis of thermally labile samples and minimizing inlet discrimination for high molecular Wt components Greater sensitivity through large volume injections Reduce sample preparation steps, resulting in enhanced productivity Solvent venting and Backflush are possible using auxiliary pressure source and CFT device
25 Multimode Inlet (MMI) Extremely flexible Split/splitless Multiple injection COC Simulation Can eliminate needle discrimination Minimal thermal stress on sample Large volume capability
26 Standard Techniques Cold split injection Cold splitless injection (COC simulation) Hot split injection Solvent venting Stationary phase/solvent venting for focusing
27 Multimode Inlet Features Hardware Temperature range of -160C to 450C 15C/sec Septum/Liner Easily Exchangeable Injection Modes: Hot S/SL, Cold S/SL, all in pulsed mode, solvent vent mode, residue removal mode Support for single stroke injections from 0.1 ml to 250 ml EPC Compatible with Packed Liners Compatible with 7890A, 5975C, 7683, CTC Combi PAL Software Ten temperature ramps Solution for solvent vent timing Fully integrated into ChemStation, MSD ChemStation, EZChrom, MassHunter
28 New Multimode Inlet Improvements Turn-top easy liner exchange Standard 11mm septa Air plus CO2, N2 cryogenic cooling No leaks at liner Standard liner dimensions Standard column nut
29 MMI Conditions Used For ASTM D6584 Column: Agilent Select Biodiesel 15 m x 0.32 mm, 0.10 μm (p/n CP9079) Carrier: Helium 5.6 ml/min constant flow Oven: 50 C (hold 1 min), then to 180 C at 15 C/min, then to 230 C at 7 C/min, then to 380 C at 30 C/min (hold 10 min) Injection: MMI Cold-Splitless, Initial temp 88 C for 0.1min, then to 350 C at 250 C/min (hold 1 min) Purge time 1.00min., Purge Flow 9.6ml/min. Detector: FID at 380 C Sampler: Agilent 7693, 1μL volume injection
30 Soy B100 Run With MMI
31 Comparison of Single Lab Precision (r) For MMI and COC Inlet wt% Glycerol wt% Monoglycerides wt% Diglycerides wt% Triglycerides wt% Total Glycerin COC MMI COC MMI COC MMI COC MMI COC MMI Run Run Average r (calc) r (spec) MMI provides same results as COC MMI provides better precision
32 Summary Agilent and ASTM have a long and successful history for developing new solutions for HPI measurements Agilent continues to provide strong support and leadership within ASTM community Agilent works with ASTM members to understand new measurement technologies and incorporate them into the latest methods 32
Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels
Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels James D. McCurry Senior Scientist Agilent Technologies Wilmington, DE USA Page 1 Application Summary There is a need to measure
More informationApplication. Gas Chromatography June 1995
Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee
More informationAgilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist
Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass James D. McCurry, Ph.D. Senior Scientist Agilent Solutions for the Analysis of Ethanol-Based Fuels Derived From Biomass Presented
More informationUsing a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application
Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville
More informationGC Inlets. An Overview. Simon Jones GC Applications Engineer
GC Inlets An Overview Simon Jones GC Applications Engineer Types of Inlets Purged Packed Split / Splitless Cool On Column Programmable Temperature Vaporization Volatiles Interface Multi Mode Inlet Where
More informationOptimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE
Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System Jim McCurry Roger Firor Agilent Technologies Wilmington, DE Page 1 Scope of the Analyzer Designed for ASTM D7798 For
More informationGC Method Compliance and Large Valve Oven Application
GC Method Compliance and Large Valve Oven Application Solution Focused Kelly Beard June 20, 2016 Compliant Methods Compliant Methods What are our options? Analyzers and Analyzer Kits High Volume Well Known
More informationComprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels
Paper # 160-6 Comprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels Elise K. Libby, John V. Seeley, Stacy K. Seeley Oakland University, Rochester, MI, USA James D. McCurry
More informationHigh Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph
Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent
More informationGas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593
Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent
More informationC2, C3, C4 Monomer Analysis
C2, C3, C4 Monomer Analysis Malgorzata Sierocinska Agilent Technologies Waldbronn Page 1 Why Analyze Monomers? To Insure Consistent Production of High Quality Polymer Protect against food contamination
More informationAgilent Multimode Inlet for Gas Chromatography
Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything
More informationAnalysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA
Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices Simon Jones Application Engineer Folsom, CA August 20, 2009 Agenda WCOT vs. PLOT columns OxyPlot A Unique stationary phase
More informationUsing the PSD for Backflushing on the Agilent 8890 GC System
Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped
More informationPage 1. Alternate Carrier Gas Considerations and Faster GC Analysis
Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down
More informationOperation and Applications of Differential Flow Modulation
Operation and Applications of Differential Flow Modulation H2 Collection channel Column 1 H2 Column 2 FID Roger L Firor, Ph.D. Agilent Technologies Chemical Analysis Group Wilmington, DE USA Flow Modulator
More informationIncreased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel
Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W
More informationSimple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer
Simple Heart Cutting with Deans Switch and Backflushing with Capillary Flow Technolgy Simon Jones Applications Engineer GC or GC/MS Analysis in Complex Matrices In complex sample matrices, there are often
More information6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR
6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR A15836 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use
More informationAgilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011
Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc.
More informationGC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method
GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN1413:211 Method Application Note Author James D. McCurry, Ph.D. Agilent Technologies Abstract
More informationFast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC
Fast GC SPEEDY GC Slide 4 Optimization Goals Primary: Minimize time for the separation of a given number of peaks Secondary: Maximize the number of peaks separated by a given column Slide 5 HOW CAN THESE
More informationAchieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)
Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,
More informationAnalysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction
Analysis of Glycerin and Glycerides in Biodiesel (B1) Using ASTM D68 and EN11 Application HPI/Petrochemicals/Polymers Author James D. McCurry Agilent Technologies, Inc. 8 Centerville Road Wilmington, DE
More informationTroubleshooting Tips & Tricks for your GC Analyzer & CFT Application
Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application 7890A/7890B GC Overview October 29, 2014 1 Definitions Carrier Gas Pressurized gas used to transport the sample through the system.
More informationGC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585
GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc. 850 Centerville
More informationAnalysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices
Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices GC Application Chemist March 3rd, 2008 Pittcon 2008, New Orleans, LA Presentation Outline WCOT vs. PLOT columns OxyPLOT A highly
More informationApplication Note. Author. Introduction. Energy and Fuels
Analysis of Free and Total Glycerol in B-100 Biodiesel Methyl Esters Using Agilent Select Biodiesel for Glycerides Application Note Energy and Fuels Author John Oostdijk Agilent Technologies, Inc. Introduction
More informationFast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application
Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co.,Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai
More informationGAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS
GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour
More informationASTM D 6730 Detailed Hydrocarbon Analysis
ASTM D 6730 Detailed Hydrocarbon Analysis Jaap de Zeeuw, Jan Pijpelink and Barry Burger Restek Corporation ASTM D 6730-01(2006)e1 Determination of Individual Components in Spark Ignition Engine Fuels as
More informationSetting up SilFlow for BackFlush in your GC
Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile
More informationApplication Note. Abstract. Authors. Environmental Analysis
High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research
More information2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx
2-D GC/MS and the Deans Switch: Theory and Applications Fred Feyerherm, Agilent Technologies Inc. Houston, Tx Introduction Simplified 2-D GC can be used to accomplish the separation of specific analytes
More informationMET-Biodiesel Capillary GC Columns
MET-Biodiesel Capillary GC Columns Product Specifications Product Features & Benefits Chromatograms FAQs Related Products Updated: February 2, 2009 Product Specifications 2 Product Specifications What
More informationApplication Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER
Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in
More informationAchieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)
Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Bill Wilson and Chin-Kai Meng Agilent Technologies, Inc. 2850 Centerville Road Wilmington,
More informationAgilent G2855A Deans Switching System
Agilent G2855A Deans Switching System Installation and Operation Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including
More informationMethanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.
Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers Application Note Abstract Versa With the rising prices of fossil fuels, more emphasis is being put on renewable resources
More informationTURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS
TURN-KEY ANALYZERS GC SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS BROAD ARRAY BROAD OF ARRAY OF CONFIGURATIONS FOR FOR SPECIAL APPLICATIONS SPECIAL THE THE PERFECT ANSWER TO A SEVERELY TO REGULATED A SEVERELY
More informationMethod Development for Capillary GC Systems. Slide 1
Method Development for Capillary GC Systems Slide 1 AREAS TO OPTIMIZE Injector Carrier gas Column temperature Slide 2 COMMON INJECTOR MODES Vaporization Injection Modes Megabore Direct Split Splitless
More informationAgilent 6850 Series II Network GC System G2630A Performance Specifications
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6850 Series II Network GC
More informationImpact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter
Cd The Chrom Doctor Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Jaap de Zeeuw, Restek Corporation, Middelburg, The Netherlands. In Part 1 of this series we focused
More informationHigh Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System
High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System Application Note Authors Frank David Research Institute for Chromatography, Pres.
More informationDetermination of Free and Total Glycerin in B100 Biodiesel
Page 1 of 5 Page 1 of 5 Return to Web Version Determination of Free and Total Glycerin in B100 Biodiesel By: Michael D. Buchanan, Katherine K. Stenerson, and Vicki Yearick, Reporter US Vol 27.1 techservice@sial.com
More informationProductivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis
Productivity Improvements for Dual Column Applications: USP and Blood Alcohol Analysis Rebecca Veeneman, PhD Applications Chemist Agilent Technologies The GC Usability Gap Usability lags features
More informationFree and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584
Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN 14105 and ASTM D6584 Introduction With today s increasing concern for the environment and the depletion of fossil
More informationTechnical Procedure for Gas Chromatography (GC-FID)
Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all
More informationAlternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis
Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different
More informationHigh-Temperature Simulated Distillation System Based on the 6890N GC Application
High-Temperature Simulated Distillation System Based on the 6890N GC Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co., Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai
More informationTypical Gas Chromatographic System
Page 72 Air Hydrogen Carrier Gas Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer Cylinders or Generators Flow Controller Column Recorder/
More informationDetermination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105
Application Note: 10215 Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105 Fausto Munari, Daniela Cavagnino, Andrea Cadoppi, Thermo Fisher Scientific, Milan,
More informationAntek Gas Chromatography Products: A Guided Tour Through Industry
ANTEK GC Application Solutions Feature the Following Detectors: Antek Sulfur and Nitrogen Chemiluminescence, Flame Ionization, Thermal Conductivity, Nitrogen-Phosphorus, Atomic Emission, Halogen Specific,
More informationDANI Transformer Oil Gas Analyzer
DANI Transformer Oil Gas Analyzer APPLICATION NOTE - AN169 Introduction Transformers are electrical devices used for energy transfer by electromagnetic induction between two or more circuits. Large oil
More informationGoing Green: The Analysis of BioFuels
Going Green: The Analysis of BioFuels Miles S Snow Sr. Product Specialist PerkinElmer LAS miles.snow@perkinelmer.com What is Biodiesel?? Biodiesel is a clean burning alternative fuel, produced from domestic,
More informationAgilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS
Agilent Portfolio Luca Godina Technical Marketing Specialist GC-GCMS 1 Summary Introduction Sample Prep Sample Introduction Inlets 7890B LTM CFT Detectors Special Solutions 13/11/12 Tirana Page 2 Agilent
More informationFausto Munari e Andrea Cadoppi ThermoFisher - Italy
The world leader in serving science Ultra Fast GC Determination of Total Hydrocarbons (C7-C40) and BTEX in Water and Soils through Direct Resistively Heated capillary columns and Robotic Autosampler. Fausto
More informationApplication Note. Authors. Abstract
Comparison of Temperature Programmable Split/Splitless and Cool On-column Inlets for the Determination of Glycerol and Glycerides in Biodiesel by Gas Chromatography with Flame Ionization Detection* Application
More informationSELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS
Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in
More informationDetailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns
Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Compatible with hydrogen, for 50% faster run times. Improved resolution between oxygenates and hydrocarbons, for more accurate reporting. Individually
More informationANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA
PET 01 - PETROLEUM ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA GASOLINE RANGE HYDROCARBONS Column Part No.: 054950 BP1, PONA 50 m x 0.15 mm ID Initial Temp.: 30 C, 5 min hold Rate 1: 2 C/min Temp.
More informationForensic Blood Alcohol Determination with the Intuvo 9000 GC
Forensic Blood Alcohol Determination with the Intuvo 9000 GC Rebecca Veeneman, Ph.D Applications Chemist The GC Usability Gap Usability lags features and performance Over the years, GC features and performance
More informationPRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System
Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and
More informationTechnical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)
Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph-mass spectrometer (GC-MS). 2.0 Scope
More informationGC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X
GC Best Practices & Troubleshooting Group/Presentation Title Agilent Restricted Month ##, 200X Troubleshooting Tips 1. Isolate the problem. (Blank Runs, Inject Un-retained Compound, Know what it is not)
More informationThe Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector
Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces
More informationSimulated Distillation Analyzers, Software, Standards, Consumables, Training
Simulated Distillation Analyzers, Software, Standards, Consumables, Training www.separationsystems.com Offering the Fullest Range of Optimized Solutions Simulated distillation (SimDis) has been used to
More informationRefinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.
Refinery Gas Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Refinery Gas Analysis Reliability Placing refinery gas analyzers in the field for over
More informationApplication Note. Authors. Abstract. Energy & Chemicals
Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors
More informationAgilent 9000 Intuvo GC Applications. Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D.
Agilent 9000 Intuvo GC Applications Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D. Summary of Intuvo Applications by Industry Environmental EPA Method 8270 Semivolatile Organic Compounds
More informationOptimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides
Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides Application Note Food Testing & Agriculture Authors Limian Zhao and Chin-Kai Meng Agilent Technologies, Inc. 85 Centerville
More informationInstalling a Purged Packed Inlet
Installing a Purged Packed Inlet Agilent 6850 Gas Chromatograph This kit contains: Accessory G2651A Description Purged packed column inlet system 1 Top block insulation 1 Bottom block insulation 1 Insulation
More informationAnalytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Shimadzu Customized GC Analyzers GC-2010 Plus Nexis GC-2030 GC-2014 Natural Gas
More informationperformance productivity reliability
Solutions that meet your demands for: performance productivity reliability Excellent Choices for Global Hydrocarbon Processing Applications Crude Oil & Natural Gas Natural Gas > Return to Table of Contents
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that EPA National Vehicle and Fuel Emissions Laboratory
More informationModel 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors
Model 8610C Gas Chromatograph Mounts up to Six Detectors and Five Injectors Ambient to 400 C Temperature Programmable Column Ovens Dimensions: 19 wide x 13.5 high x 14.5 deep Implement virtually any EPA
More informationInstalling the 6850 Direct Valve Column Connector Kit
Use this kit to bypass the inlet and connect your 6850 gas or liquid sampling valve directly to a column. To use this kit, your 6850 GC must have a purged packed inlet. This kit contains: Installing the
More informationGC Analysis of PCBs in Fish Oil by Direct Injection Without Any Sample Cleanup. Philip L. Wylie, Ph.D. Sr. Applications Chemist Agilent Technologies
GC Analysis of PCBs in Fish Oil by Direct Injection Without Any Sample Cleanup Philip L. Wylie, Ph.D. Sr. Applications Chemist Agilent Technologies Pittsburgh Conference, 2008 Paper 1120-1 Tuesday, 8:30
More informationMeeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems
Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems Application Note Hydrocarbons Authors Michael Woodman Agilent Technologies, Inc. Chemical Analysis Solutions 2850
More informationREFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns
RESTEK REFINED innovative petrochemical solutions Detailed Hydrocarbon Analysis Featuring Rtx -DHA Columns Individually tested to meet DHA method criteria; guaranteed column-to-column reproducibility.
More informationAgilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory
Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory For the Agilent Intuvo 9000 Gas Chromatograph Installation Instructions Parts Supplied Table 1 Parts supplied with an Agilent G3969A
More informationBeverage Grade Carbon Dioxide
Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION The Challenge Carbon dioxide, used in the production of carbonated soft drinks and other beverages,
More informationSame Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities
: What Are You Willing To Do? Daron Decker Chromatography Technical Specialist Page 1 Agilent Restricted 3 Options Same Column and Gas Type Try Different/Faster Velocities Same Column, Switch He to H2
More informationAnalysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID
Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID Introduction P Gorst-Allman (LECO Africa Pty. Ltd) and B-J de Vos (NMISA). The analysis
More informationPerforming ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software
Install a capillary column in the oven of the SRI GC. The ASTM method suggests a 12 meter.32mm id narrow-bore column coupled with a 2.5 meter guard column but permits the use of any column which exhibits
More informationRestek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades
High Speed PONA Analysis For Detailed Hydrocarbon Analysis Extended (DHAX) Using Hydrogen Carrier Gas For The Determination of Individual Components In Spark Ignition Fuels Barry L. Burger, Neil Johansen,
More informationLiquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases
Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an
More informationJaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation
Liner Selection in GC Jaap de Zeeuw Restek Middelburg, The Netherlands What is a liner? A liner is an inert glass tube that is positioned inside the injection port of the GC The sample solution is introduced
More informationMeeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems
Meeting the Requirements of ASTM D 6591-06 ( IP548/06 ) with Agilent 1200 LC Systems M.Woodman, Chemical Analysis Solutions Unit, Wilmington, Delaware, USA M.Sierocinska, European Field Support Centre,
More informationHigh-Performing Restek PAL SPME Fibers
Restek Sample Handling High-Performing Restek PAL SPME Fibers Suitable for a wide range of analyte chemistries and sample matrices. Reliable performance meets or exceeds other brands. Robust aluminum hub
More informationAgilent Multimode Inlet
Agilent Multimode Inlet Large Volume Injection Tutorial Agilent Technologies Notices Agilent Technologies, Inc. 2009 No part of this manual may be reproduced in any form or by any means (including electronic
More informationCustomer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard
Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained and certified
More informationRefinery and Natural Gas Analysis
Refinery and Natural Gas Analysis 2 ENSURE MORE ACCURATE AND EFFICIENT ANALYSIS TAKE CONTROL OF YOUR OPERATIONS Oil refineries and natural gas producers around the world require their lab operations to
More informationPhenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals
Phenomenex Exclusive! Easy Seals Inlet Base Seals Guaranteed fit for Agilent 5000, 6000 and 7000 Series GCs The Easy Seals Gold Standard No Strained Hands No Troublesome Washers or Adaptors Continuing
More informationLarge Volume Injection of Polycyclic Aromatic Hydrocarbons
JSB is an authorised partner of Large Volume Injection of Polycyclic Aromatic Hydrocarbons Application Note - Environmental #113 Author Anne Jurek Applications Chemist EST Analytical Cincinnati, OH Abstract
More informationDetection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector
Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural
More informationTechniques for Improving the Reproducibility of GC Analysis
Techniques for Improving the Reproducibility of GC Analysis Primary Areas of Concern Sample Auto-Injector Inlet Column Detector Sample Extract Handling and Care It is critical that the sample extract be
More informationCustomer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard
7890 GC Standard Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained
More informationEvaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS
Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS Application Environmental Authors Wei Luan and Chuanhong Tu Agilent Technologies (Shanghai) Co., Ltd. 412 Ying
More informationDual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector
Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector Application Note Hydrocarbon Processing Authors ChunXiao Wang Agilent Technologies
More information