Size: px
Start display at page:

Download "Searle Air Cooled Condensers. GEA Refrigeration. Searle"

Transcription

1 Searle ir ooled ondensers GE Refrigeration Searle

2 Searle ir ooled ondensers Range benefits eeting your specification - Our range has literally 1000s of models, created through a modular design and variety of fan sizes, offering a greater choice to match your requirements. ssured performance - ll our condensers are Eurovent ertified, enabling you to rest easy, with the knowledge that our unit will perform as specified. odels Eurovent No. Fans Designed to be quiet - designed restrictions using the latest 6, 8 & 1 pole fansets. In addition, we offer E technology across the standard range which offers variable speed control and high efficiency. D efficient - Due to rising energy costs, efficiency is becoming a key industry issue and is increasingly important on end-user criteria. Our new units use the latest technology to ensure greater energy efficiency. Backing our beliefs - We are so confident in our product that we offer one years warranty on all condensers and an additional one year warranty on all E fans (subject to standard Terms & onditions of Sale and excluding corrosion through misapplication). E 1-8 Fansets The fansets chosen for the range offer the best combined performance for air volume, noise and efficiency available in the refrigeration industry, customers can select the latest E technology, offering high efficiency and speed controllability. G 1-16 oils oils are manufactured from high-quality materials ensuring a quality product without compromise. These coils have been tested extensively in Searle s Research & Development facility and ensures an optimised cooling efficiency. 1-9 Standard coils are manufactured from copper tubes, which are mechanically expanded into fully collared holes in the fins. This ensures an effective and permanent bond between the tube and the fin, maximising heat transfer characteristics. X 1-9 Within the coil casework surround, each fan chamber is separated by internal baffle plates to prevent windmilling of off-cycle fans. lternative fin materials are available to give added protection in polluted or saline atmospheres: - u/v - opper tube / vinyl coated aluminium fins u/u - opper tubes / copper fins u/et - opper tubes / electro tinned copper fins u/l - Blygold ll standard coils are fully leak and strength tested to 6 bar for a maximum ope pressure of 7 bar. V - 16 ulti-sectioning ll models are suitable for multi-sectioning, permitting more than one refrigeration system to operate with a single condenser. V - 16 ll V-bank and full width flat-bed units are twin section as standard. arger V-bank models are manufactured in sections, per coil to ensure they conform to category 1 of the Equipment Directive.

3 General Range Features Options apacity 15 DT1 Rows of Fans Supply E Fans diabatic ooling System Fin aterials & ph I V u 7-8 kw 1 or 1 & ph I V u 11-8 kw 1 or ph I V u kw 1 ph I V u kw 1 ph I V u - 70 kw ph I V u 6-86 kw ph I V u kw

4 ir ooled ondenser Options ontrol Options There are various optional Searle control packages available, including fully variable speed controlled products using Searle inverter control or the latest E fan control system. The control options include: - E speed control - Inverter speed control - Triac speed control - Dual speed step control - Single speed control If a speed control method is utilised Searle recommends adding the option of internal motor protection. diabatic ooling System Searle s adiabatic cooling system is designed to enhance the thermal performance by reducing the effective incoming air temperature during peak ambient and load conditions. ir temperature reduction is achieved by spraying water into the incoming airstream (please see Searle s diabatic brochure for further details). Other Options Searle offers a wide range of accessories and additional options, including anti-vibration mounts and optional leg extensions - to enhance fresh air in difficult locations. For further details please contact your Searle representative. Vertical ounting Flat bed units may be specified with the coil vertical for horizontal air flow systems. Sub-ooling Sub-cooling is achieved by the use of an integrated sub-cooling section which utilises approximately 10% of the coil surface. This provides up to 7 of sub-cooling at the standard condition of 15K DT1. Ope below 15K DT1, the amount of sub-cooling is reduced. The total heat of rejection capacity, inclusive of sub-cooling, will be reduced by 5%. The system should be designed so that refrigerant passes from the condensing section into a liquid receiver or liquid trap to prevent gas from entering the sub-cooling section. Some larger units will have the end cooling outlet at the opposite end to other connections.

5 Quality ssured Searle is a quality assured company to ISO 9001:008 encompassing Performance Testing, anufacturing Systems and Inspection Procedures. Eurovent ertification The range is certified under the Eurovent ERTIFY- ondensers program, with performances rated in accordance with B5 EN 7 and sound with EN187. Data covered includes: performance, sound power, mean sound pressure, power input and surface area. abelling abelling is now part of the Eurovent ertify-ll scheme. Rating is based on the ratio of nominal duty to power input with banding as in the table below. Where R= Nominal apacity / Total fan power input E arking Searle s condensers are E marked under the ow Voltage Directive. Under the Equipment Directive, they are category 1 or SEP and therefore excluded from it. Fan Data Searle offers a variety of fan types and speeds to suit specific requirements. The fansets include guarding in accordance with B5 EN ISO otors are environmentally protected to IP5. The wire fan guards are of welded construction and coated in a weatherproof durable synthetic finish for maximum corrosion protection Typical fan New fan The blade profile of Searle s new fan and its proximity to the fanplate reduces the occurrence of air-recirculation due to a more projected airflow. Fansets The standard fansets used in the entire Searle condenser range are external rotor motors with either die cast aluminium or plastic sickle bladed impellers. The sickleshaped design of the blades reduce the fan noise considerably versus other fansets available. The fansets are supplied with a full bell mouth fan plate, optimised to provide the highest efficiency, lowest noise fan currently available. otors can be connected in Delta or Star configurations for high or low speed operation or, as an option can be switchable between the speeds. The motors can also be externally speed controlled by triac or inverter systems. E Fansets For speed control the E motor offers high efficiency whilst being extremely quiet over its entire operational range. t nominal speed, there is an energy saving of about 10%. In the controlled range, both relative and absolute savings are substantially more pronounced. Fan type & Pole N5 6 Pole N6 Pole N6 6 Pole N6 8 Pole N8 6 Pole N8 8 Pole N8 1 Pole Q8 1 Pole Diameter odel ength B Speed (rpm) F (mp) Delta S (mpl) N5 Pole B Single Phase N5 8 Pole N9 6 Pole 9 E Technology 09 E Technology 500mm 60mm 800mm 9m B B B B B B B B B B B Star Variable Variable Note: The figures in the table are for 00V/ph/50Hz operation and are per fan. Speed (rpm) F (mp) S (mpl). Single Phase

6 Noise Data The mean unit sound pressure data at is given for each model in the catalogue and is certified as part of the Eurovent scheme. power testing and sound pressure calculation are carried out in accordance with EN187. ean sound pressure levels are for a parallel piped surface surrounding the unit on a reflective plane.: levels and sound spectrum are available on request. Dewpoint The capacities shown in this brochure are rated at dew point. This is the pressure/temperature condition at which a refrigerant gas begins to condense on the surface. s some refrigerants have significant glide (e.g. R07/ 07), the saturated gas and saturated liquid temperatures are not necessarily the same. It is important to ensure that all the components of a system are selected using the same method. power correction factors for multiple fans No Fans Whilst the use of mid-point does make selection easier, it is difficult to measure on site. t the catalogue point of 15K DT1, mid point capacities would be approximately 9% higher for R07 than the equivalent dew point figures shown in the tables orrections orrection Factors ultiply the capacity tables by the following factors depending on the DT1 temperature difference: R507, R1a, R0 R07, R07, DT1 8K 10K 1K 15K 17K 0K

7 Product Selection Software This document contains screenshots of selected features of the latest version of the Searle Product Selection software. This release retains the familiar interface which our customers tell us they like, but adds a number of new features requested by both customers and sales staff. Introductory Screen The main screen incorporates the traditional layout and appearance of the existing program, but now includes all product types within one program. The customer can select the type of product by clicking an icon or selecting from a drop-down list; whichever they find most convenient. The box to the left of the Select button allows the customer to enter a filter (for example for a ondenser selection) to limit the number of models considered. Specification as a PDF File Specification of Selected odels The new introductory screen places Searle within the context of our new parent group, GE Refrigeration. ain Screen The product specification of one or more models is presented in the traditional way. lthough not visible on this screenshot, the specification screen allows the customer to select optional extras (by ticking checkboxes at the bottom of the specification). The nett price of the unit (including extras and taking into account customer discounts) is immediately calculated and displayed. new feature of this version is that the specifcation can be presented as a PDF file. The appearance of the specification document will be enhanced to include company logos, contact information and anything else required to create a professional proposal document. The specification document can include one or more specification pages and the relevant drawings (extracted from the standard product range brochures). Note: also in the above screenshot that bookmarks in the PDF file allow quick navigation to the relevant part of a large specification document. Website Keep up to date with our products and latest news by visiting the website, co.uk. i) Selection software Use selection software and check product availability. fully interactive version of theselection software is available on-line at www. searle.co.uk. Our unique website allows visitors to use an interactive product selector, showing the latest stock availability. Simply click on Help e hoose and choose your product range, such as condensers, dry coolers and coolers. Then input your requirements and a range of suitable products will be shown. These products can be added to a basket, fromwhich you can for a quote from the Searle UK or export sales team ii) Online ordering If you buy direct from Searle an online customer account can be created for customer-specific pricing and online ordering. For further details please speak with your sales representative. iii) Download brochures and technical docments Visitors can view and download the latest information from the website. Our full product range and installation and maintenance instructions can be found on the Downloads menu bar. 7

8 E The E range of air-cooled condensers is based upon the well established E fin heat exchange matrix, combined with the HyBlade range of fans from ebmpapst. This combination offers a versatile and economical solution to many refrigeration and air conditioning applications. The range consists of one to eight fans in three coil depths and modules with 500 and 60 mm, 6 and 8 pole fans. This results in a wide range of capacities, noise levels and footprints to meet the diverse requirements of the industry. Optional extras for the E range include vertical orientation (1 to fan), multi circuiting, integral sub cooling section, alternative fin materials and coating. ontrol options include fan cycling, variable speed (including E) and individual fan isolators. The E range is also available as a fluid cooler designated DE. odel selections can be made either directly from the catalogue by using the popular Searle selection software available on D, as a download from the website or interactively on-line at E Features odule length sizes (,B,) 500mm or 60mm HyBlade fansets,6,8 pole or E Optional coil fin materials and coating Powder coated robust casework factory fitted or separate control options ompact design Vertical coil (1- fans) or Horizontal coil (1-8 fans) Wall mounting kits available for Vertical coil 1- fan units HyBlade 8

9 E Range E E 1 H - N 6 - odule length, B, Bank of fans 1 or Fans per bank 1 - oils rows,, Orientation H = Horizontal, V = Vertical Fans type N5 = 500mm,N6 = 60mm, otor speed 0, 06, 08, E, XX = ess fansets 1 = 1 - phase, = - phase oil material = opper tubes/ luminium fins, V = opper tubes/ Vinyl coated luminium fins U = opper tubes/ opper fins, ET = opper tubes/ opper fins electro-tinned BG = nti corrosion protection 9

10 E Selection Data odel (15 K DT1 - Dew Point) R0 & R507 D E T (High Speed) ir evel at (15 K DT1 - Dew Point) R0 & R507 S T R (ow Speed) ir evel at Total Surface Internal R0 harge kw m³/s db() W kw m³/s db() W m ² dm ³ kg 500mm pole 1 phase E D EB D E D E D EB EB E D EB D E D E D E D EB EB EB D E D E D E D EB EB D E D EB E D EB EB mm pole phase EB E E 8 7. E E E EB E E E E E EB E E E E E EB E E E E E EB E E EB E E E E E 1 7. EB E E E E E E E E 1 7. EB E E EB E E E E E EB E E E E E E E E EB E E E E E EB E E E E E

11 E Selection Data odel (15 K DT1 - Dew Point) R0 & R507 D E T (High Speed) ir evel at (15 K DT1 - Dew Point) R0 & R507 S T R (ow Speed) ir evel at Total Surface Internal R0 harge kw m³/s db() W kw m³/s db() W m ² dm ³ kg 500mm 6 pole 1 phase E EB B E B E B EB B EB B E EB B E B E B E EB B EB B EB B E B E E B EB B EB B E B EB B E B EB B EB B mm 6 pole phase EB D D 8 7. E D EB D EB E E EB D D E D EB D EB E EB D D E E D EB D EB D D EB E E D E EB D EB E E

12 E Selection Data odel (15 K DT1 - Dew Point) R0 & R507 D E T (High Speed) ir evel at (15 K DT1 - Dew Point) R0 & R507 S T R (ow Speed) ir evel at Total Surface Internal R0 harge kw m³/s db() W kw m³/s db() W m ² dm ³ kg 500mm 8 pole phase E B E EB E EB EB E B E EB E EB E B EB E EB E E B EB EB E EB E EB EB mm 8 pole phase EB B 8 7. E B EB B EB B B E B B E B EB B E B EB B EB B B E B B 1 7. EB B E B E B 1 7. EB B EB B EB B B E B B E B E B EB B EB B B E B B E B

13 E odel ayout E EB 90 E

14 E odel Drawings B1 B E SINGE BNK HORIZONT UNIT W (Overall egs) Optional Fan Isolator Optional J/Box E VERTI UNIT 88.0 H (Overall) 8.0 D fixing centres fixing centres E DOUBE BNK HORIZONT UNIT W (Overall egs) Optional Fan Isolator Optional J/Box 1 fixing hole 11.0mm x 16.5mm in base of each leg D fixing centres 1

15 Dimensions pprox Dry Fans oil B1 B D W H Weight Inlet outlet odel Banks per rows /V U/ET bank mm mm mm mm mm mm mm kg kg E /8 7/8 E /8 7/8 E /8 7/8 E /8 1.1/8 E /8 7/8 E /8 7/8 E /8 7/8 E /8 1.1/8 EB /8 7/8 EB /8 7/8 EB /8 1.1/8 EB /8 1.1/8 EB /8 7/8 EB /8 7/8 EB /8 1.1/8 EB /8 1.1/8 E /8 7/8 E /8 1.1/8 E /8 1.1/8 E /8 1./8 E /8 7/8 E /8 1.1/8 E /8 1.1/8 E /8 1./8 15

16 G The G range of fully weather-proofed air cooled condensers is suitable for a wide variety of applications, with a duty range of 15kW to 770kW. These capacities can be achieved both in flat-bed horizontal and vertical configurations. In addition, Searle has created the latest innovation of blowthrough horizontal coil designs for high ambient temperature applications. Due to the large number of options only a selection of the range is available in this catalogue, selection is best achieved using the Selection data tables or the Searle selection software, either on-line at or via the Searle Selection D. Searle achieves a close specification match through module length options of 100mm, m and 1800mm in a single (1158mm) or double (01mm) bank configuration. The range is up to 8 fans in length, combined with coil sizes between to row and multiple standard fan options up to 9m. Searle is able to manufacture units up to 1m in length with 16 fans For the ultimate in fan speed control, Searle offers the E fan, a high efficiency and low noise, complete fan speed control package. For full details of the E fanset and the suitable applications please refer to the front of this brochure. 16

17 G Range G G 1 H - Q 8 1 D - odule length (100mm), B (m), (1800mm) Bank of fans 1 or Fans per bank 1-8 (G), 1-6 (GB), 1-5 (G) oils rows,, Orientation H = Horizontal, V = Vertical Fans type N8 (800mm), Q8 (800mm), N9 (9m), 09 (9m), 99 (990mm) otor speed pole: 06, 08, 1, 09E (ax 855rpm), 9E (ax 600rpm) D = Delta, S = Star, = Speed oil material = opper tubes/ luminium fins, V = opper tubes/ Vinyl coated aluminium fins U = opper tubes/ opper fins, ET = opper tubes/ opper fins electro-tinned Note: Isolators and control box shown are additional extras 17

18 G 800mm 6 pole Selection data 18 odel (15KDT1 - Dew Point) R0 & R507 kw ir m /s Delta (High Speed) level at db() W (15KDT1 - Dew Point) R0 & R507 kw ir m /s Star (ow Speed) level at db() W Total Surface Internal R0 harge m dm kg G11H E D G16H E D G1H E D G8H E D GB11H E D GB1H E D GB1H E D GB1H E D GB15H E D GB1H E E GBH E D GBH E D GBH E D GB5H E D GB6H E E G11H D D G1H D D G1H D D G5H D D G11H E D G1H E D G1H E D G1H E D G15H E D G16H E D G1H E D GH E D GH E D GH E D G5H E D G6H E D G7H E D G8H E D GB11H D GB15H D GB1H E D GB1H E D GB6H E D G11H D G1H D G1H D G5H D G11H D D G16H D D G1H D D G8H D D GB11H D GB1H D GB1H D GB1H D GB15H D GB1H D GBH D GBH D GBH D GB5H D GB6H D G11H G1H G1H G1H G1H GH GH GH

19 odel (15KDT1 - Dew Point) R0 & R507 kw G 800mm 8 pole Selection data ir m /s Delta (High Speed) level at db() W (15KDT1 - Dew Point) R0 & R507 kw ir m /s Star (ow Speed) level at db() W Total Surface Internal R0 harge m dm kg G11H D G16H D G1H D G8H D GB11H GB1H GB1H GB1H GB15H GB1H D GBH GBH GBH GBH GB6H D G11H B G1H B G1H B G5H B G11H G1H G1H G1H G15H G16H G1H GH GH GH G5H G6H G7H G8H GB11H B GB15H B GB1H B GB6H B G11H B G1H B G1H B G5H B G11H B G16H B G1H B G8H B GB11H B GB1H B GB1H B GB1H B GB15H B GB1H B GBH B GBH B GBH B GB5H B GB6H B G11H B B G1H B B G1H B B G1H B B G1H B B GH B B GH B B GH B B G5H B B

20 G 800mm 1 pole Selection data 0 odel (15KDT1 - Dew Point) R0 & R507 kw ir m /s Delta (High Speed) level at db() W (15KDT1 - Dew Point) R0 & R507 kw ir m /s Star (ow Speed) level at db() W Total Surface Internal R0 harge m dm kg G11H B G16H B G1H B G8H B GB11H B GB1H B GB1H B GB1H B GB15H B GB1H B GBH B GBH B GBH B GB5H B GB6H B G11H B G1H B G1H B G5H B G11H B G1H B G1H B G1H B G15H B G16H B G1H B GH B GH B GH B G5H B G6H B G7H B G8H B GB11H GB15H GB1H GB6H G11H G1H G1H G5H G11H B G16H B G1H B G8H B GB11H GB1H GB1H GB1H GB15H GB1H GBH GBH GBH GB5H GB6H G11H G1H G1H G1H G1H GH GH GH G5H

21 odel (15KDT1 - Dew Point) R0 & R507 kw G 9m 6 pole Selection data ir m /s Delta (High Speed) level at db() W (15KDT1 - Dew Point) R0 & R507 kw ir m /s Star (ow Speed) level at db() W Total Surface Internal R0 harge m dm kg G11H E E GB11H E E G11H E E G11H E D G11H E D GB11H E D GB11H E D G11H D D G11H D D G1H E E GB1H E E GB1H E E G1H E E G1H E E G1H E D G1H E D GB1H E E GB1H E E GB1H D D G1H D D GB1H E E G1H D D G1H D D G1H E E GB1H E E GBH E E GB1H D D GH E E G1H E E G1H D D GB15H E E G15H E E GB1H D D GBH D D G15H E E GB16H E E GBH E E G1H D D GH D D G16H E E GH E E GB15H E D G18H E E G15H D E GB16H E E G17H E E G15H D E GBH E E GB16H E E GBH D D G18H E E GH E E G18H E E GH D D GB5H E E G5H E E GBH D D G5H E E GB6H E E GH D D G6H E E GB5H D D G8H E E G5H D E GB6H E E

22 G odel ayout G GB

23 G odel ayout G

24 G odel Drawings ommon junction box Fixing hole 15.0 in base of each leg 0.0 B1 B 0.0 Horizontal Unit Vertical Unit 1 bank Overall casework Optional fan isolator Overall casework 1 Fixing hole in base of each leg Fixing centres Horizontal Unit Vertical Unit Overall casework Optional fan isolator 1 bank Fixing hole in base of each leg Fixing centres Overall casework Notes: ll dimensions in mm. ommon junction box will vary in size and position depending on the control option required

25 Dimensions G G G G G G G G G G G G G G G G GB GB GB GB GB GB GB GB GB GB GB GB G G G G G G G G G G G Notes: odel Fans per bank oil rows B1 mm mm mm mm kg kg kg kg Total unit dry weight is dependent upon the coil material used ( = opper tubes with luminium or Vinyl coated aluminium fins, U = opper tubes with opper fins or opper fins electro-tinned). Total Unit Dry Weight * 1 bank * bank * * * * * * * * * * * * * * * * G * G * G * G * G * G * G * G * GB * GB * GB * * * * * * * * * * * GB * GB * GB * * * * * * * * * * * * G * G * G * G * B * * U 5

26 / X The and X ranges of fully weatherproofed air cooled condensers feature a new range of coil module sizes to extend the coil surface to air volume ratio and thereby increase the air-volume efficiency factor. The series has a duty range of 18kW to 596kW and the X series has a duty range of kw to 75kW. Both ranges are available in flat-bed horizontal and vertical configurations and have the latest innovation of blow-through horizontal design for high temperature applications. The full fanset options are available, including the 9m E energy efficient fanset, which enables a highly efficient, very low noise complete fan speed-control package. Full details of the E fanset and ideal application areas can be found in the E brochure. Due to the wide variety of condensers available only a selection of the range is available in this catalogue. For full selection data either refer to the Selection data tables or use the Searle selection software, either on-line or via the Searle Selection D. The range is available in a single width of 159mm and the X range is available in a single width of 01mm, both with module lengths of 100mm, m and 1800mm, up to 6 fans and to coil rows. 6

27 / X Range or X 1 6 H - N 8 1 D - odule length (100mm), B (m), (1800mm) Bank of fans 1 Fans per bank 1-8 ( & X), 1-6 (B & XB), 1-5 ( & X) oils rows,, Orientation H = Horizontal, V = Vertical Fans type N8 (800mm), Q8 (800mm), N9 (9m) 09 (9m), 99 (990mm) otor speed 06, 08, 1 or E D = Delta, S = Star, = Speed, Variable speed oil material = opper tubes/ luminium fins, V = opper tubes/ Vinyl coated aluminium fins U = opper tubes/ opper fins, ET = opper tubes/ opper fins electro-tinned Note: Isolators and control box shown are additional extras 7

28 / X Selection Data odel 800 mm 6 Pole (15KDT1 - Dew Point) R0 & R507 kw ir m /s Delta (High Speed) level at db() W (15KDT1 - Dew Point) R0 & R507 kw ir Star (ow Speed) X18H m 8 Pole 11H E D m /s level at db() W Total Surface Internal R0 harge m dm kg 11H D D B11H D H H D D B1H D H B1H D H H H B15H H B16H H D H D X11H D XB11H X11H B X1H D XB1H X1H B XB1H X1H B X1H B X1H B XB15H B X15H B XB16H B X17H B11H D D H D H E D B1H D D H B1H D D H H D H B15H D H D B16H D H D D H D D X11H D D XB11H X11H X1H D D XB1H X1H XB1H X1H X1H X1H XB15H X15H XB16H X17H D X18H D

29 odel (15KDT1 - Dew Point) R0 & R507 ir Delta (High Speed) level at (15KDT1 - Dew Point) R0 & R507 ir Star (ow Speed) level at Total Surface Internal kw m /s db() W kw m /s db() W m dm kg 800 mm 8 Pole 11H B mm 1 Pole / X Selection Data B11H B B H B H B B1H B B H B B1H B B H B H B B H B B15H B B H B B16H B B H B H B X11H B XB11H B X11H X1H B XB1H B X1H XB1H B X1H X1H B X1H XB15H B X15H XB16H B X17H B X18H B H B B11H H H B B1H H B1H H H H B15H H B16H H H X11H XB11H X11H X1H XB1H X1H XB1H X1H X1H X1H XB15H X15H XB16H X17H R0 harge X18H

30 odel ayout B 0

31 X odel ayout X XB X 1

32 odel Drawings ommon unction box 1 Fixing hole 15.0 in base of each leg 0.0 B1 B 0.0 Horizontal Unit Vertical Unit Overall casework Optional fan isolator Overall casework Fixing centres X Vertical Unit 95.0 X Horizontal Unit Overall casework Optional fan isolator Overall casework Fixing centres 1 fixing hole in base of each leg Notes: ll dimensions in mm. ommon junction box will vary in size and position depending on the control option required.

33 Dimensions B B B B B B B B B B B B B B odel /X Fans per bank oi rows mm B1 mm B mm Total Unit kg Dry WeightU kg kg X Total Unit Dry Weight U kg mm Notes: Total unit dry weight is dependent upon the coil material used ( = opper tubes with luminium or Vinyl coated aluminium fins, U = opper tubes with opper fins or opper fins electro-tinned).

34 V The V range extends the versatility of Searle s ir cooled condensers into a V-Bank configuration with a combination of coil widths and module lengths, fans wide. The available range has a duty from 6kW to 1088kW. Searle achieves a close specification match by offering three module length options of 100mm, m or 1800mm across three coil width options in the small footprint V- Bank formation. The V has x 15mm coils and the V has x 1905mm high coils with fans wide, all sizes offer the choice of to 6 fans in length. ombined with coil sizes from to row coils and multiple standard fan options up to 9m, this range of V configuration units is comprehensive. Searle now offers the E fan, a highly efficient and very low noise complete control package. Full details of the E fan and the best-suited application areas are included at the front of this brochure. Due to the large number of options only a selection of the range is available in this catalogue, selection is best achieved using the ondenser data tables or the Searle selection software, either on-line at or via the Searle Selection D.

35 V Range V V 6 - N 8 1 D - odule length (100mm), B (m), (1800mm) Bank of fans 1-6 Fans per bank 1-6 oils rows,, Orientation S = Small (mm) H = Horizontal, V = Vertical Fans type N8 (800mm), Q8 (800mm),N9 (9m), 09 (9m), 99 (990mm) otor speed 06, 08, 1, Q1 or E D = Delta, S = Star, = Speed, E Variable speed oil material = opper tubes/ luminium fins, V = opper tubes/ Vinyl coated aluminium fins U = opper tubes/ opper fins, ET = opper tubes/ opper fins electro-tinned Note: Isolators and control box shown are additional extras 5

MAKING REFRIGERATION GREENER

MAKING REFRIGERATION GREENER Searle KME air cooler MAKING RERIGERATION GREENER The Searle KME cooler range from Kelvion is ideally suited to large cold rooms and small warehouses where an efficient cooling solution is required. The

More information

DKG/DVG Fluid Dry Coolers

DKG/DVG Fluid Dry Coolers DKG/DVG Fluid Dry Coolers SPECIFICATION Introduction Due to the many combinations of temperatures, flow rates and working fluids which may be encountered, it is not possible to catalogue capacities and

More information

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER Making refrigeration greener KELVION KME COMMERCIAL COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners worldwide More

More information

COMMITTED TO ENGINEERING INNOVATION

COMMITTED TO ENGINEERING INNOVATION Commercial and Industrial coolers Searle Commercial and Industrial Coolers COMMITTED TO ENGINEERING INNOVATION Searle cooler WE ARE KELVION THE NEW BRAND IN HEAT EXCHANGE GEA Heat Exchangers has changed:

More information

Air-Cooled Condensers - Axial Fan

Air-Cooled Condensers - Axial Fan Air-Cooled Condensers - Axial Fan Freon Applications 3 290 Tons > > U S E D F O R I N D U S T R IAL A ND/OR C O MMERCIAL F REON A PPLI C AT I O N S 3-2 9 0 T O N S. The Global Leader In Heat Exchange Technology

More information

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw Condensers NEOSTAR 18 kw 12 kw Friga-Bohn reserves itself the right to make changes at any time without preliminary notice - Photos non-contractual www NEW! The air cooled condenser units of the new NEOSTAR

More information

HEATING & COOLING COIL PRODUCTS AIR COOLED CONDENSERS

HEATING & COOLING COIL PRODUCTS AIR COOLED CONDENSERS HEATING & COOING COI PRODUCTS AIR COOED CONDENSERS Small footprint low profile 6, 8, 10, 12 or 16 pole fan motors Noise levels to ISO 3745 Variable fan speed option HEATING & COOING COI PRODUCTS AIR COOED

More information

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension Air cooled Condensers New condenser generation with better performance Capacities 9-1060 kw Ripple Fin tubing Floating coil block suspension Eurovent certified Capacities based on ENV 327 voor R404A *DX

More information

NSM. R134a HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

NSM. R134a HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE. NSM ir/water chillers for outdoor installation with free cooling glycol free Screw compressors, shell and tube heat exchangers and axial fans from 306 2028kW 1402/9603 glycol free R134a HIGH EFFIIENY LSO

More information

Innovative Engineering. Catalogue. Condenser. ECU, ECV and ECW Industrial Condenser Series. Technical Brochure

Innovative Engineering. Catalogue. Condenser. ECU, ECV and ECW Industrial Condenser Series. Technical Brochure Innovative Engineering Catalogue Condenser ECU, ECV and ECW Industrial Condenser Series Technical Brochure Product range Applicable for all HFC refrigerants Series Capacity kw Fin Spacing Air-flow direction

More information

DCH Commercial Contents Standard Features Cabinet Features

DCH Commercial Contents Standard Features Cabinet Features DH ommercial 7½ - ½ Ton Packaged Heat Pump Up to. EER &. OP ooling apacity: 90,000 0,000 BTU/h Heating apacity: 90,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8

More information

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications...

More information

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW G4 LOW AIR / DUAL THROW UNIT COOLER EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW DEPC - High & Medium Temperature Application Dual Air Throw Capacity: 4.4kW to 38.4kW Low Noise

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information

REMOTE AIR COOLED CONDENSERS RC-C Series & DV/DH Series

REMOTE AIR COOLED CONDENSERS RC-C Series & DV/DH Series REMOTE RC-C Series & DV/DH Series RC Series Standard Features: Passivated fins. Sickle blade fans. All fans statically and dynamically balanced, aerodynamically constructed for economical and quiet operation.

More information

RCTM. Condensor, kw. RC Low up to 66 kw. RC Mid&High up to 1200 kw. Quick facts. General

RCTM. Condensor, kw. RC Low up to 66 kw. RC Mid&High up to 1200 kw. Quick facts. General TM Condensor, 8-1200 kw RC Low up to 66 kw RC Mid&High up to 1200 kw General RC is a series of robust and reliable aircooled remote condensors dedicated for air condition both for comfort and technical

More information

DC INVERTER DUCTED AIR CONDITIONERS

DC INVERTER DUCTED AIR CONDITIONERS DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial 3-5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 35,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... 3 rankercase

More information

low carbon centrifugal Pod blowers

low carbon centrifugal Pod blowers low carbon centrifugal Pod blowers torin-sifan For over 100 years, torin-sifan have been a leader in servicing the Air Movement requirements of our customers. From our Head Office and Manufacturing facility

More information

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h D ommercial 3- to 6-Ton Packaged Air onditioner 13 SEE / Up to 11.3 EE ooling apacity: 34,600 71,000 BTU/h ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 7 Airflow Data...

More information

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE. NEW NSM ir/water chillers for outdoor installation with free cooling Screw compressors, shell and tube heat exchangers and axial fans from 306 2028kW 1402/9603 free cooling R134a HIGH EFFIIENY LSO T PRTIL

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h DT ommercial 3-5 Tons Packaged Air onditioner Up to 15.5 SEER / Up to 13.0 EER ooling apacity: 35,600 60,000 BTU/h ontents Nomenclature...2 Product Specifications...4 Expanded ooling Data...6 Airflow Data...18

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial - 5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 5,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... rankercase

More information

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11. PG ommercial ooling apacity: 90,000 8,000 BTU/h Heating apacity: 68,000 BTU/h Three-Phase 7½- to 2½-Ton Self-ontained Packaged Gas/Electric Units up to.5 EER 80% AFUE Standard Features R-40A chlorine-free

More information

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW G4 Low Air Process Room Chiller Series EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW DEPC - High & Medium Temperature Application Dual Air Throw Capacity: 4.4kW to 38.4kW Low Noise

More information

DXP 100 Air Cooled Condenser

DXP 100 Air Cooled Condenser Air Cooled Condenser Applied for CERTIFY-ALL DX COOLERS PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene

More information

Reciprocating Compressors Industrial Quality

Reciprocating Compressors Industrial Quality www.kaeser.com Reciprocating Compressors Industrial Quality Air delivery 0.87 to 16.10 m³/min Pressure 5.5 to 15 bar What do you expect from an industrial quality reciprocating compressor? As a compressed

More information

Select the right heating or cooling coil for your project! Instantly size and cost your chosen coil with the SPC2000 coil-selection program.

Select the right heating or cooling coil for your project! Instantly size and cost your chosen coil with the SPC2000 coil-selection program. www.spcoils.co.uk SPC2000 Coil Selection Program User guide V2.1 Select the right heating or cooling coil for your project! Instantly size and cost your chosen coil with the SPC2000 coil-selection program.

More information

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS Dry Cooler CERTIFY-ALL DX COOLERS PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene glycol mixture. The coolers

More information

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h PH ommercial 7½- to 12½-Ton Self-ontained ooling / Heating apacities: 90,000 118,000 BTU/h Packaged Heat Pump up to 11.5 EE up to 3.5 P Standard Features -410A chlorine-free refrigerant High-efficiency

More information

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h DP15H ooling apacity: 23,600-57,500 BTU/h Packaged Air onditioner UP TO 15 SEER 2 to 5 Tons ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Airflow Data...16 Heater Kit Data...17

More information

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h DH ommercial Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches efrigerant accumulator ontactor with lugs

More information

NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw

NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw Oil injected rotary screw compressors with direct transmission. NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw NOBEL - NOBEL DV Rotary screw compressors featuring direct

More information

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

09GDV and 09LDV. Air Cooled Dry coolers and Condensers Air Cooled Dry coolers and Condensers Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 09GDV and 09LDV Nominal cooling

More information

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h PH ommercial ooling apacity: 5, 7, BU/h Heating apacity: 4,6 7, BU/h - to 6-on Packaged Heat Pump SEE / up to. EE & 7.7 HSPF Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor

More information

Industrial air coolers for cooling & freezing applications Cu/Al

Industrial air coolers for cooling & freezing applications Cu/Al Goedhart VCI Industrial air coolers for cooling & freezing applications Cu/Al R404A - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VCI The extensive range Goedhart VCI single discharge

More information

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h H Packaged Heat Pump ooling apacity: 24,000-57,500 BTU/h Heating apacity: 22,000-54,500 BTU/h 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve PS blower

More information

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h D ommercial - to 6-ton Packaged as/electric Units SEE / up to. EE 80% AFUE ooling apacity: 4,600 7,000 BTU/h Heating apacity: 6,800 0,400 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

HWT 1402/9603. free cooling

HWT 1402/9603. free cooling irwater chillers for outdoor installation with free cooling Screw compressors, shell and tube heat exchangers and axial fans NSM Cooling capacity 306-2001kW HWT 14029603 free cooling HIGH EFFICIENCY LSO

More information

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h D ommercial 7½ - ½ Ton Packaged Air onditioners Up to. EER ooling apacity: 88,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8 Airflow Data... rankcase Heater...0

More information

09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS

09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS 09DK-4SB 09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS PERFORMANCE DATA CERTIFIED DIMENSION PRINT 1994 Carrier Corporation Syracuse, New York 13221 Form 09DK-4SB Supersedes 09DK-3SB Printed in U.S.A.

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

AlfaGreen - Dry Coolers DC DCD DCV

AlfaGreen - Dry Coolers DC DCD DCV lfagreen - Dry Coolers DC DCD DCV General Contents DC Single fan row version DCD Double fan row version DCV V version Certifications and reliability The lfa Laval quality system is in accordance with ISO

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

INDUSTRIAL range. Oil-free Scroll Compressors. Belt driven, fix or variable speed kw (3-30 HP) 10/2013

INDUSTRIAL range. Oil-free Scroll Compressors. Belt driven, fix or variable speed kw (3-30 HP) 10/2013 INDUSTRIAL range OS Oil-free Scroll Compressors Belt driven, fix or variable speed 2.2-22 kw (3-30 HP) GB 10/2013 Company Profile FINI boasts more than 60 years of experience and it is one of the most

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

Medium Pressure Centrifugal Fans

Medium Pressure Centrifugal Fans Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

ExpressBuild STANDARD FAN RANGE

ExpressBuild STANDARD FAN RANGE AIR COMFORT FIRE SAFETY ExpressBuild STANDARD FAN RANGE OUR SHORT LEAD TIME FAN RANGE ExpressBuild CONCEPT & PRINCIPLES When a short lead time solution is important, choose an ExpressBuild Fan product

More information

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h ooling apacity: 4,000-59,000 BTU/h GP13H - to 5-Ton Packaged Air onditioner 13 SEER / R-410A Standard Features Energy-efficient compressor with internal relief valve PS blower motor; EEM blower motor on

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ooling apacity: 18,000 to 60,000 Heating apacity: 18,000 to 60,000 High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ontents Nomenclature... 2 Product Specifications... 3 Expanded

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Section 4 e c tio - P lat F a n s

Section 4 e c tio - P lat F a n s Plate Fans Section 4 The Fläkt Woods Plate Fan Range is the result of detailed market analysis and intensive research and development by the world leaders in air movement technology. By setting and achieving

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

Goedhart FC38. Standard air coolers Cu/Al. R404A - Coolants. engineering for a better world. GEA Heat Exchangers. Goedhart FC38S.

Goedhart FC38. Standard air coolers Cu/Al. R404A - Coolants. engineering for a better world. GEA Heat Exchangers. Goedhart FC38S. Goedhart FC38S Goedhart FC38D Goedhart FC38L Goedhart FC38 Standard air coolers Cu/Al R404A - Coolants engineering for a better world GEA Heat Exchangers Paragraph Styles Goedhart FC38 The range GEA Goedhart

More information

TVFC Dry and adiabatic cooling

TVFC Dry and adiabatic cooling Dry and adiabatic cooling Key benefits Largest adiabatic capacity Highest degree of redundancy Unrivalled reliability cooler characteristics Counter flow, adiabatic pre-cooling, axial fan, induced draft

More information

Alfa Laval Optigo CC. Commercial air coolers - Single discharge. Extended range featuring draw-through & blow-through models

Alfa Laval Optigo CC. Commercial air coolers - Single discharge. Extended range featuring draw-through & blow-through models Alfa Laval Optigo CC Commercial air coolers - Single discharge Extended range featuring draw-through & blow-through models Optigo CC(B) Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the

More information

AIR HANDLING UNITS YSE

AIR HANDLING UNITS YSE IR DIG UITS YSE YSE Series ir andling Units YORK YSE Series ir andling Units are designed to provide a comfortable environment for factories, warehouses, office and stores etc. The coils can be used to

More information

42HS Fan Coil Unit (High Static Pressure)

42HS Fan Coil Unit (High Static Pressure) 42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning

More information

INDUSTRIALS GROUP. Screw Compressors. ESM Fixed Speed & VS Variable Speed

INDUSTRIALS GROUP. Screw Compressors. ESM Fixed Speed & VS Variable Speed INDUSTRIALS GROUP Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed GARDNER DENVER COMPRESSED AIR TECHNOLOGIES The perfect fit to maximise productivity The growing industrial demand for

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge Alfa Laval Optigo CD Commercial air coolers - Dual discharge Optigo CD Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the Alfa Laval platform for commercial air cooler ranges. Common distinctive

More information

Alfa Laval Optigo CS. Commercial air coolers - Slim line

Alfa Laval Optigo CS. Commercial air coolers - Slim line Alfa Laval Optigo CS Commercial air coolers - Slim line Optigo CS Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the Alfa Laval platform for commercial air cooler ranges. Common distinctive

More information

Industrial air coolers for cooling & freezing applications StSt/Al

Industrial air coolers for cooling & freezing applications StSt/Al Goedhart VRB / VRZ Industrial air coolers for cooling & freezing applications StSt/Al NH 3 - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VRB/VRZ The range Goedhart VRB/VRZ single discharge

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge Alfa Laval Optigo CD Commercial air coolers - Dual discharge Optigo CD Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the Alfa Laval platform for commercial air cooler ranges. Common distinctive

More information

Küba SG industrial

Küba SG industrial 66 Küba Blue Line : Specific advantages The is a master of customisation. No matter how great the demand for power, the is the answer. Its versatility allows the Küba SG industrial to master the most complex

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136

More information

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TABLE OF CONTENTS NOMENCLATURE............................. 3 FEATURES.................................... 4 KV SERIES FEATURES.........................

More information

Airsock unit coolers THOR-A. Standard coolers in a revolutionary design

Airsock unit coolers THOR-A. Standard coolers in a revolutionary design Airsock unit coolers THOR-A Standard coolers in a revolutionary design O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................ 2 Eurovent......................................

More information

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603 NEW NSM ir/water chillers for outdoor instation Screw compressors, shell and tube heat exchangers and axial fans ooling capacity 302 2100kW 1402/9603 cooling only R134a ermec participate in the EUROVENT

More information

BPF. Centrifugal Plug Fans

BPF. Centrifugal Plug Fans BPF Centrifugal Plug Fans Introduction INTRODUCTION Plug Fans S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged

More information

Reciprocating Compressors Industrial Quality

Reciprocating Compressors Industrial Quality www.kaeser.com Reciprocating Compressors Industrial Quality Flow rates from 6 to 4 l/min Pressure 7 to 35 bar What do you expect from an industrial quality reciprocating compressor? As a compressed air

More information

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise Product Brochure Fan coil units for suspended ceilings HyPower-Geko Energy efficient Powerful Hygienic Low noise Optimal climate: Hygienic. Efficient. Sustainable. The HyPower-Geko fan coil units generate

More information

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TAbLE Of CONTENTs NOMENCLATURE............................. 3 features.................................... 4 KV series features.........................

More information

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

CKMS Low Voltage Three-Phase Squirrel-cage Induction Motor TOSHIBA Top Runner Motor. Premium Gold Motor

CKMS Low Voltage Three-Phase Squirrel-cage Induction Motor TOSHIBA Top Runner Motor. Premium Gold Motor S-1001 ow Three-Phase Squirrel-cage Induction otor TOSI Top unner otor Premium old otor Premium fficiency for the reen arth igh efficiency technology of TOSI otor for over 120-year-old brings more value

More information

Condensers. 7 kw 198 kw.

Condensers. 7 kw 198 kw. ondensers 7 198 www.friga-bohn.com 6 models from 7 to 198 : 34 basic models and 8 additional models coupling two identical units, ( or 3 fans). ither horizontal or vertical mounting as standard. NOMNLATUR

More information

modular multi intelligent, environmental and versatile

modular multi intelligent, environmental and versatile modular multi intelligent, environmental and versatile system overview 2-pipe R407C heat pump VRF system From 8 to 46 HP in one piping system (19 steps) Active leak detection system option Up to 40 indoor

More information

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE PRODUCT SELECTION DATA Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers 09PE Translation of the original document N 20030, 02.2017 Use 09PE The 09PE range is particularly

More information

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - 09PE Translation of the original document N 20030, 03.2015 Use The 09PE range, available

More information

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER GLOBL STNDRD COOLER GLOBL STNDRD OIL-TO-IR COOLING SYSTEMS WITH C-MOTOR PRODUCT INFORMTION KG CooL-Line is a standard line of products from the market leader in high performance aluminium cooling systems.

More information

Industrial air cooler VCI Cooling/Freezing

Industrial air cooler VCI Cooling/Freezing Industrial air cooler VCI Cooling/Freezing Cu/Al - R404A GEA Refrigeration Goedhart Goedhart VCI The extensive range Goedhart VCI single discharge ceiling mounted industrial air coolers are available with

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

PHCD-Series. Catalog

PHCD-Series. Catalog PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,

More information

Alfa Laval Optigo CC. Commercial air coolers - Single discharge

Alfa Laval Optigo CC. Commercial air coolers - Single discharge Alfa Laval Optigo CC Commercial air coolers - Single discharge Optigo CC Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the Alfa Laval platform for commercial air cooler ranges. Common distinctive

More information