FAN TYPE FAN LOCATION MAX PAGE PERFORMANCE

Size: px
Start display at page:

Download "FAN TYPE FAN LOCATION MAX PAGE PERFORMANCE"

Transcription

1 381 FN TYPE FN LOTION MX PGE PERFORMNE ROOF 9.2m 3 /s 382 ROOF OWLS/TERMINLS ROOF

2 ROOF FNS STYLISH, LOW PROFILE ROOF FN WITH WIDE DUTY RNGE

3 ENEFITS UNOTRUSIVE DESIGN Extremely rigid ultra low profile GRP cowl easily accommodated on all building profiles cowl is also UV resistant. NY ROOF PROFILE Soaker sheets and flashing plates are available to cater for all roof profiles. ENERGY EFFIIENT ll 3 phase models are compatible with Ecosmart controls providing the most energy efficient cost effective solution. QUIETER SYSTEM Widest range of impeller types together with matching silencers provide the perfect acoustic solution. SYSTEM ONTROL Ecosmart compatibility allows other fans/ HU s to interface directly with the Terminator. (3 phase only). VOIDS HET LOSS Integrated backdraught shutters, limits heat loss from building when unit is off. Motorised dampers are optional. FLEXILE INSTLLTION The cowl can be wall mounted vertically for exposed weather location. PERFORMNE OPTIONS xial, mixed flow or centrifugal impeller options cater for all your systems particular pressure and sound requirements. OLOUR MTH Standard cowl colour is goose wing grey (S 0005), (although any S or RL colour can be supplied). NILLRIES Full range of attenuators, mounting curbs, wall plates, etc. are available to complete your installation. WRRNTY Terminator has a 3 year warranty. Ecosmart Terminator has a 5 year warranty. FN OPTIONS Shutters GRP cowl irdguards (plastic coated wire mesh) Motor mounting frame (galvanised steel) Motor mounting frame (galvanised steel) If the Terminator unit is to be used with one of the Nuaire drop in attenuators, the unit s inlet guard needs to be removed first. xial Fan ode TR. ase/venturi plate galvanised steel ase/venturi plate galvanised steel ase/venturi plate galvanised steel owl fixing threaded inserts Optional fan inlet guard Sealing strip owl fixing threaded inserts Fan inlet guard (standard up to unit size 630). Optional for units 710 and above) Sealing strip Motor mounting frame (galvanised steel) Optional fan inlet guard Sealing strip entrifugal Fan ode TR. Purlin ox urb Purlin ox urb xial Flow (TR) Purlin ox urb entrifugal (TR) Mixed Flow (TRM) Mixed Flow Fan ode TRM. 383

4 PERFORMNE - ROOF EXTRT FNS asing Terminator TR xial Flow Units V ISO 5801 S848 Part Fan Static Pressure (Pa) Terminator TRM Mixed Flow ir volume flow rate (m/s) 15 V ISO 5801 S848 Part ode descriptions TRS Range code 2. Impeller = xial M = Mixed Flow = entrifugal 3. Shutter 4. Fan size 5. Number of poles 6. Phase: 1 = Single phase, 3 = Three phase 600 ontrol descriptions (ES) () () Fan Static Pressure (Pa) ES = Full Ecosmart controls MS interfaces and commissioning. ontrols (as 2 & 3 below) full compatibility with Ecosmart sensors = MS interfaces 0-10V, volt free run and fail indication. ommissioning/speed control built in. 100 djustable trickle and boost if required 3. = ommissioning/speed control built in. djustable trickle and boost if required ll the above control options are preprogrammed with a soft start function. 3 ir volume flow rate (m/s) The above control options are provided in a purpose made module, mounted remote from the unit. Other controls to be specified separately see selection table

5 PERFORMNE - ROOF EXTRT FNS ELETRI L & SOUND XIL IMPELLER TR Motor Induct inlet Sound Power Levels (d re 10-12W) Open inlet/ owl Power FL S S Open inlet Octave band mid frequency (Hz) outlet urve ode Size Phase RPM (kw) (amps) (amps) H/s Open outlet K 2K 4K 8K d@ 3m 1 TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS D induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS D induct inlet open inlet open outlet TRS80L-43 E induct inlet open inlet open outlet TRS100H-63 F induct inlet open inlet open outlet TRS80H-43 E induct inlet open inlet open outlet TRS100L-43 F induct inlet open inlet open outlet TRS100H-43 F induct inlet open inlet open outlet The electrical and sound information in the table is nominal. d@3m is hemispherical, free field. Start currents (sc) are DOL other than for motors of 4 kw and above which are star delta. * Motor electrical supply, 1=1 phase (230V, 50Hz) 3=3phase (400V, 50Hz). 385

6 PERFORMNE - ROOF EXTRT FNS Terminator TR entrifugal V ISO 5801 S848 Part Fan Static Pressure (Pa) ir volume flow rate (m/s) ELETRI L & SOUND ENTRIFUGL IMPELLER TR Motor Induct inlet Sound Power Levels (d re 10-12W) Open inlet/ owl Power FL S S Open inlet Octave band mid frequency (Hz) outlet urve ode Size Phase RPM (kw) (amps) (amps) H/s Open outlet K 2K 4K 8K d@ 3m 21 TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS D induct inlet open inlet open outlet TRS induct inlet open inlet open outlet TRS D induct inlet open inlet open outlet TRS D induct inlet open inlet open outlet The electrical and sound information in the table is nominal. d@3m is hemispherical, free field. Start currents (sc) are DOL other than for motors of 4 kw and above which are star delta. *Motor electrical supply, 1=1 phase (230V, 50Hz) 3=3phase (400V, 50Hz). Note: The TRS unit is no longer available for purchase

7 PERFORMNE - ROOF EXTRT FNS ELETRI L & SOUND MIXED FLOW IMPELLER TRM Motor Induct inlet Sound Power Levels (d re 10-12W) Open inlet/ owl Power FL S S Open inlet Octave band mid frequency (Hz) outlet urve ode Size Phase RPM (kw) (amps) (amps) H/s Open outlet K 2K 4K 8K d@ 3m 16 TRMS induct inlet open inlet open outlet TRMS induct inlet open inlet open outlet TRMS induct inlet open inlet open outlet TRMS induct inlet open inlet open outlet TRMS induct inlet open inlet open outlet The electrical and sound information in the table is nominal. d@3m is hemispherical, free field. Start currents (sc) are DOL other than for motors of 4 kw and above which are star delta. * Motor electrical supply, 1=1 phase (230V, 50Hz) 3=3phase (400V, 50Hz). DIMENSIONS - ROOF FNS DIMENSIONS ( MM) & WEIGHT Fan Units owl Size D (min) E F Weight Kg TRS sq sq 20 TRS sq sq 20 TRS sq sq 30 TRS sq sq 30 TRS sq sq 45 TRS sq sq 45 TRS sq sq 45 TRS sq sq 45 TRS sq sq 63 TRS D sq sq 63 TRS80H-43 E sq sq 103 TRS80L-43 E sq sq 103 TRS100H-43 F sq sq 144 TRS100H-63 F sq sq 144 TRS100L-43 F sq sq 144 TRS sq sq 20 TRS sq sq 30 TRS sq sq 30 TRS sq sq 51 TRS sq sq 51 TRS sq sq 51 TRS sq sq 51 TRS D sq sq 82 TRS D sq sq 82 TRS D sq sq 82 Fan Units owl Size D (min) E F Weight Kg TRMS sq sq 23 TRMS sq sq 23 TRMS sq sq 35 TRMS sq sq 53 TRMS sq sq 53 Min urb height E owl End view F x F min. Side view D x D min. 387

8 INSTLLTION DIMENSIONS ( mm) owl Size H J K D E F uilders Upstand Profile Roof Installation Soaker Sheet Purlin Trimmer H x H over curb J x J inside soaker sheet x x Note: Wooden curb and caps to be hardwood or treated softwood of minimum 50mm thickness. Decking Roof Installation H x H over curb Purlin / ox urb Foam Seal supplied Vertical Profile Sheet Installation Wall plate Trimmer x Neoprene Profile Filler Y x Y Plastic capped self-tapping screws (by others) QUIK SELETION GUIDE x & inside trimmer angles Insulation optional ROOF FNS Ecosmart Speed ontrols Frequency uto- Drop-in Standard Drop-in Long Fan Units owl Size ontrol Pack Electronic Inverter transformer ttenuator ttenuator Roof urb TRS NS1-3 - SPON3.5 TRDSS- TRDSL- P- TRS NS1-3 - SPON3.5 TRDSS- TRDSL- P- TRS NS1-6 - SPON3.5 TRDSS- TRDSL- P- TRS NS1-6 - SPON3.5 TRDSS- TRDSL- P- TRS NS1-6 - SPON3.5 TRDSS- TRDSL- P- TRS NS1-6 - SPON3.5 TRDSS- TRDSL- P- TRS D - NS1-6 - SPON7.5 TRDSS-D TRDSL-D P-D TRS NS1-6 - SPON7.5 TRDSS- TRDSL- P- TRS NS SPON7.5 TRDSS- TRDSL- P- TRS ES-IS3.3-3IS3.3 - TRDSS- TRDSL- P- TRS D ES-IS5.6-3IS5.6 - TRDSS-D TRDSL-D P-D TRS80H-43 E ES-IS12.5-3IS TRDSS-E TRDSL-E P-E TRS80L-43 E ES-IS5.6-3IS5.6 - TRDSS-E TRDSL-E P-E TRS100H-43 F ES-IS13.2-3IS TRDSS-F TRDSL-F P-F TRS100H-63 F ES-IS5.6-3IS5.6 - TRDSS-F TRDSL-F P-F TRS100L-43 F ES-IS7.3-3IS7.3 - TRDSS-F TRDSL-F P-F TRMS NS1-3 - SPON7.5 TRDSS- TRDSL- P- TRMS NS1-6 - SPON7.5 TRDSS- TRDSL- P- TRMS NS1-3 - SPON3.5 TRDSS- TRDSL- P- TRMS ES-IS5.6-31S5.6 - TRDSS- TRDSL- P- TRMS NS SPON7.5 TRDSS- TRDSL- P- TRS NS1-3 - SPON3.5 TRDSS- TRDSL- P- TRS NS1-3 - SPON7.5 TRDSS- TRDSL- P- TRS NS1-6 - SPON7.5 TRDSS- TRDSL- P- TRS NS SPON7.5 TRDSS- TRDSL- P- TRS NS SPON7.5 TRDSS- TRDSL- P- TRS TRDSS- TRDSL- P- TRS NS1-6 - SPON7.5 TRDSS- TRDSL- P- TRS D TRDSS-D TRDSL-D P-D TRS D TRDSS-D TRDSL-D P-D TRS D TRDSS-D TRDSS-D P-D

9 PERFORMNE - ROOF INPUT/SUPPLY FNS TI Terminator TI V Fan Static Pressure (Pa) ISO 5801 S848 Part TI - Roof mounted input/supply fan is supplied complete with ird Guards and Motor side Finger guard ir volume flow rate (m /s) ELETRI L & SOUND TI Motor Sound Power Levels (d re 10-12W) Open inlet/ owl Power FL S Open inlet Octave band mid frequency (Hz) outlet urve ode Size Phase RPM (kw) (amps) (amps) Open outlet K 2K 4K 8K d@ 3m 1 TI I O TI I O TI I O TI I O TI D I O I = Open Inlet O = Open Outlet The electrical and sound information in the table is nominal. *Open outlet d@3m input/supply. DIMENSIONS - ROOF INPUT/SUPPLY FNS TI DIMENSIONS (mm) & WEIGHT ode D (min) E F Weight Kg TI sq sq 20 End View TI sq sq 30 TI sq sq 30 TI sq sq 45 TI sq sq 63 F QUIK SELETION GUIDE TI Fan Drop In Standard Drop In Long ode ttenuator ttenuator Roof urb Side View TI TRDSS- TRDSL- P- TI TRDSS- TRDSL- P- TI TRDSS- TRDSL- P- min. height curb E TI TRDSS- TRDSL- P- TI TRDSS-D TRDSL-D P-D D Soaker sheets and flashing plates are available to suit all roof profiles. ontact Nuaire for details. 389

10 DIMENSIONS - WLL FRME KIT DIMENSIONS ( mm) E Fixing centres Unit D E * * * 825 D ** 900 * Three holes equally spaced. ** Four holes equally spaced Wall Mounting Kits Note: unit must be installed using the appropriate wall mounting plate and with the longer cowl dimension running horizontally. Roof profile prepared to accept a Purlin ox urb. D Neoprene Profile Filler Important that timber is flush with outside of wall and secured with coach bolts (by others). Use Flowsil 32 flexible silicone sealant filler on all joint faces to form a fillet for complete weatherseal. J x J Y x Y x x Wall plate Wall plate Trimmer x Y x Y x Y x Y Note: Details of Terminator owls and Supply/Extract owls can be found on page 407. Flashing strips by others. Plastic capped self-tapping screws (by others). DMPERS uilt up Damper unit and urb ox Sleeve Damper irway (D) urb ox Sleeve overall () Sometimes reversed Y Z a Z DIMENSIONS - DMPERS Motorised Damper unit DIMENSIONS ( mm) Damper ode X Y Z ba Kg Y X Z TRDM TRDM TRDM TRDM-D TRDM-E TRDM-F X Z Damper motor fitted is "Motor open/motor closed". For Motor open/spring Return option add '-S' after terminal size e.g. TRDM--S

11 DROP IN SILENERS Standard ttenuator DIMENSIONS (mm) & WEIGHTS owl Unit ode Type Unit Size E Weight Z TRDSS- Standard TRDSS- Standard TRDSS- Standard TRDSS- Standard TRDSS- Standard TRDSS- Standard D TRDSS-D Standard E TRDSS-E Standard F TRDSS-F Standard Standard ttenuator Insertion Losses Frequency Hz K 2K 4K 8K Dynamic ttenuation (d) Long ttenuator DIMENSIONS (mm) & WEIGHTS Flange sq 50 mm owl Unit ode Type Unit Size E Weight Z TRDSL- Long TRDSL- Long TRDSL- Long TRDSL- Long TRDSL- Long TRDSL- Long D TRDSL-D Long E TRDSL-E Long F TRDSL-F Long sq 11.1mm hole dia. sq Note: ir Pressure Drop of ttenuator (Pa) = Z x Q2 where Z = Factor listed in table right Q = ir Volume Flow Rate (m3/s) Long ttenuator Insertion Losses Frequency Hz K 2K 4K 8K Dynamic ttenuation (d) URING PREFRI TED UR DIMENSIONS ( mm) urb ode D P P P P D P E P F Dims internal or external. Manufactured in galvanised steel these curbs will reduce design work and guarantee correct unit mounting when on site. Note: Upper faces of curb are fitted with robust sealing strip. D 391

12 WIRING FOR TR, TRM, TR ND TI UNITS (EXEPT TR 100H-43) (Single phase units - 3 wire supply) Single Speed 1 Phase Ecosmart Fan unit T1 T2 X L N L1 L2 L3 E Remove this link if: 1: switched live signal is connected 2: ES-PIR, ES-T or MS Signal is connected Single Speed 3 Phase NOTE: Remove link between X+L when using a speed control (see below) L N 230V 1 phase 50Hz supply * Note: When T1 & T2 are fitted, connect as shown. Fan unit T1 T2 Do not connect U1 V1 W L3 L2 L1 (U) (V) ( W) N L SL DP L N RET FULT RUN DMPER MS signal Ecosmart Min Max SL run on 0 1 Trickle Test 0V 0-10V Pw r Standby Fan 1 Fan 2 Heating ooling Fault Frost Tx Rx Speed ontrol, Transformer 1 Phase Fan unit To Starter ontrol ircuit (where fitted) L1 L2 L3 400V 3 phase 50Hz supply T1 T2 X L N NOTE: Link removed between X+L as shown when using a speed control 1 ONTTER (U) (V) (W) Earth U V W E onnections to fan via screened power cable. Purpose made glands are provided to earth the screening E N L1 L2 L3 E N L1 L2 L3 Mains supply connections 400V 50Hz 3ph + Neutral Via local isolator 'NET' connection Note: Internal connections between the supply terminals, output contactors the P and inverter are made at the factory ontrol L N L2 N N L1 L N 230V 1 phase 50Hz supply * Note: When T1 & T2 are fitted, connect as shown. (Single phase units - 3 wire supply) TR100H-43 3 Phase Fan unit T1 T2 U1 Unit Supplied for Single speed operation Interchange any two supply leads to reverse rotation V1 W1 U2 V2 W2 Speed control, Electronic 1 Phase Fan unit ontrol L N L2 N L1 X+L as shown when using a speed control T1 T2 X L N L N 230V 1 phase 50Hz supply * Note: When T1 & T2 are fitted, connect as shown. To starter ontrol ircuit (230V max) 400V 3phase & N supply Unit Wiring The terminator range of units are pre-wired from the motor to an enclosed terminal box. On TR (axial) models this box is located at the end of a 600mm long flexible conduit which hangs underneath and is fixed to a convenient surface by the installer. These units will require bottom access to complete wiring. On TRM (mixed flow) and TR (centrifugal) models the box is located on the fan plate or motor bridge inside the cowl. On these units it will be necessary to remove the cowl to gain access. When wiring in the unit take care to avoid rotating components and also gravity shutters. 20mm holes are provided in the fan base plate to bring wiring out from inside the building. onnection details heck that the electrical supply is compatible with the unit (see unit rating plate). onnection details are supplied with speed controls. ll wiring must be carried out in accordance with regulations for electrical installations and comply with the requirements of the local supply authority. Ensure that the direction of rotation is correct. Single phase units are checked during manufacture for correct rotation. Three phase units must be tested on site and, if incorrect, interchange any two supply leads to reverse impeller direction

13 ONTROLS D E able access over Fixing hole positions EOSMRT ONTROL ( mm) Fan ode mm mm mm Weight Kg ES-IS ES-IS ES-IS ES-IS ES-IS ES-IS ES-IS ES-IS ES-IS ES-IS ES-IS ELETRONI SPEED ONTROL ( mm) Unit ode D E Weight Kg NS NS NS The electronic speed controllers provide infinitely variable speed control from preset minimum to maximum. ll models feature a boost start function, which applies maximum power to the motor for a few seconds to prevent motor stalling before returning to selected speed. Wiring to the motor can be either 2-wires or 3-wires control depending on the motor design. The enclosures for ES1-3 and ES1-6 are rated to IP45 with the ES1-10 rated at IP54. ll controllers meet LVD and EM directives for safety and electromagnetic compatibility. Please note: The mains power supply to the controller must be appropriately sized and installed via a local isolation switch (by others). The isolator must also accommodate the switched live (if used). The mains supply from the ecosmart controller to the fan must be appropriately sized, not exceeding 25 metres and must be a screened power cable, earthed at both ends. four point glanding plate is formed from the base of the control and in order to main EM compliance, a Zerohm EM glanding kit is supplied. n isolator should be located adjacent to the fan. ontra and run and standby fans will require two controls, one for each fan. ll integrated sensors plug directly into the control panel. Refer to product datasheet No for further information. TRNSFORMER SPEED ONTROL ( mm) Single Phase Unit ode Weight Kg SPON SPON SPON utotransformers having class F insulation are used to provide discrete voltage steps. ll models are fitted with suitable fuses for short-circuit protection. The controller casing is manufactured from plastic pre-coated steel or impact resistant polycarbonate. ll models are suitable for indoor installations only. ll controllers meet LVD and EM directives for safety and electromagnetic compatibility. Transformer speed controls produce a pure sine wave output resulting in quiet motor operation.transformer controls are therefore preferred for noise sensitive applications. 393

14 INVERTER SPEED ONTROL DIMENSIONS (MM) Front View These are a range of frequency inverters for controlling the speed of 3 phase motors. Standard range are 400V 3 phase input units covering motor rating from 0.75kW to kw. Higher ratings and single phase input models are available upon request. The inverters are microprocessor controlled and use state of the art Insulated Gate ipolar Transistor (IGT) technology. This makes them reliable and versatile. special pulse-width modulation method with selectable pulse frequency permits quiet motor operation. omprehensive protective functions provide excellent inverter and motor protection. The inverters default factory settings, is ideal for a large range of simple motor control applications. The inverters can also be used for more advanced motor control applications via its comprehensive parameter lists. The inverters can be used in both stand alone applications as well as being integrated into utomation systems. Fan code Motor Kw Weight Kg 3IS IS IS IS IS IS IS IS IS IS IS IS IS IS IS IS IS ode descriptions 3 IS Phase supply 2. Inverter Speed ontrol 3. Output urrent Rating

15 ONSULTNTS SPEIFITION FN DESRIPTION The Roof mounted extract/supply fans shall be located in the positions indicated on the drawings and in accordance with the relevant fan schedule. It shall be a low profile cowl manufactured in flame retardant GRP. The fan shall be of the Terminator type and shall be supplied complete with backdraught shutters, birdguard, purlin box curb, hand guard, specific details of the curb and and purlin to be confirmed by the main contractor. EOSMRT SYSTEM OPERTION The Ecosmart controls will enable the unit to automatically vary its speed as it receives signals from one of the interconnected sensors. When the signal is received the fan shall either increase speed gradually until the required level is achieved or it will work on a trickle and boost principle. This will then move the fan duty point from trickle/background ventilation rate to the required boost ventilation rate. oth the trickle and boost rates are infinitely variable, easy to adjust and remove the need of a main balancing damper. The mechanical contractor shall make due allowance for supporting the fan via the provision of purpose made trimmers between purlin. The trimmers shall be sized to adequately support the weight of the fans. The Fan unit shall have a 3 year warranty, first year parts and labour the remainder parts only. Ecosmart Terminator shall have a 5 year warranty, first year parts and labour the remainder parts only. 2. MS INTERFES The fan unit can be provided with the following integrated MS interfaces 0-10 volt contacts to provide a full MS interface. This will enable the following functions:- Switch the unit on/off. Switch from low speed to high speed. Full speed control facility. The unit and ancillaries shall be of the Terminator type as manufactured by Nuaire Ltd. 2 No. Volt free contacts to provide fan run and failure indication to provide system status. ONTROL SPEIFITION The fan unit can be supplied with one of the following control options:- 1. Ecosmart controls (3 phase only) The compact Ecosmart control system complete with all necessary controls to facilitate the operation of the ventilation system. It shall be come complete with an integral factory fitted Ecosmart P which will control the fan unit within the desired design parameters and provide the interface between all external control devices and the unit itself. The fan unit shall have the following energy saving components integrally mounted, pre-wired to interface with the purpose made P, all components pre-wired, configured and factory fitted by the manufacturer: - Integral Frequency inverter/speed controller. Integral maximum and minimum speed adjustment for commissioning. Integral adjustable run on timer. Integral MS interfaces 0-10V speed adjustment. Integral MS interfaces Volt free failure and status indication. Integral background ventilation switch (trickle switch). Multiple ID sockets for interconnection of sensors or fans using pre-plugged 4-core low voltage cable. n integrated commissioning/speed control to accurately commission the system, with minimum and maximum speeds easily adjusted via a miniature dial, as recommended in Part L. This will enable the unit to be configured to run between set parameters thus saving motor power and limiting noise. 3. OMMISSIONING SET UP The fan unit can be provided with an integrated commissioning/speed control to accurately commission the system, as recommended in Part L, minimum and maximum speeds easily adjusted via miniature dial. The commissioning set up facility directly controls the integrated speed control/frequency inverter. 4. STNDRD ONTROLS The unit shall be provided with a standard speed control or starter in accordance with the manufacturers recommendations. Terminator has a 3 year warranty. Ecosmart Terminator has a 5 year warranty. ll equipment shall be as manufactured by Nuaire Ltd. 395

16 ROOF OWLS ND TERMINLS ROOF OWLS ND TERMINLS OWLS DIMENSIONS ( mm) To provide a weatherproof route for supply & exhaust air to your ducted system. owls are manufactured from flame retardant polymer and can be supplied with gravity backdraught shutters, bird guards and hand guards. The terminal is finished in S0005 Grey as standard. ll S or RL colours are available. The cowl will normally be fitted to the upstand by a roofing contractor or builder. The owl can be fitted without shutters on a 0-60 degree pitched roof with its longer side running down the roof slope. The owl can be fitted with its longer side running across a slope of less than 85 degrees from the horizontal. When fitted to a wall the longer side must run horizontal. Typical code: TRTS- Note: S = Shutters H x H Note: ir Pressure Drop of owl (Pa) = Z x Q 2 where Z = Factor listed in table below Q = ir Volume Flow Rate (m 3 /s) ode D E H Weight Kg Z Extract Z Intake TRTS D x D min. TRTS TRTS TRTS-D TRTS-E E x E TRTS-F inside weatherskirt SUPPLY/ EXTRT OWLS DIMENSIONS ( mm) Supply/Extract owl: rigid flame retardant cowl, conforming with S476 (Part 1 class 11) supplied in grey (S 00 05) as standard (any S or RL colours available), fixing directly to the base using non-rusting sealed fixings. ir plenum is manufactured from galvanised steel incorporating supply & extract chambers. Rigid spigots are provided for connection of duct work. Supply & extract chamber is fitted with a bird guard. Typical code: TRSE1 ode D E F G H Weight Kg TRSE H x H F D x D min. TRSE TRSE TRSE TRSE TRSE TRSE Resistance to airflow of this item is negligible. G G dia dia E x E inside weatherskirt 407

17 ROOF OWLS ND TERMINLS ROOF OWLS ND TERMINLS ONT. FILTERED TERMINLS DIMENSIONS ( mm) Low profile terminals are to be supplied by Nuaire. The terminal is to be rectangular, constructed in aluminium alloy and with non-rusting fixings. Twin inlets fitted with inlet/bird guards and an integral weather skirt. Filtered units are to be fitted with filter frames for removal and replacement of S2831 and S2963 filters. Typical code: 630LPDT/1 - Disposable Filter. 630LPWT/1 - Washable Filter. Inlet ird Guard Filters 100 min ode D Weight Kg Z Extract Z Intake D Inside weather skirt 630LP*T/ LP*T/ LP*T/ Note:* D = Disposable * W= Washable NON- FILTERED TERMINLS ( mm) Low profile terminals are to be supplied by Nuaire. The terminal is to be rectangular, constructed in aluminium alloy and with non-rusting fixings. Twin inlets fitted with inlet/bird guards and an integral weather skirt. Typical code: 315LPT/1 Note: ir Pressure Drop of owl (Pa) = Z x Q 2 where: Z = Factor listed in table below Q = ir Volume Flow Rate (m3/s) Optional ccess Panels, filters withdraw from one side ode D Weight Kg Z Extract Z Intake 315LPT/ LPT/ LPT/ LPT/ LPT/ Inlet ird Guard D Inside weather skirt 100 min 1000LPT/ LPT/ LPT/ LPT/

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION TWI FAS TWI SQUIF TECHICAL IFORMATIO TWI SQUIF FAS RU & STADBY SOLUTIO FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIOS. FOR HIGH TEMPERATURE RAGE REFER TO SMOKE SECTIO 264 TWI FAS TWI SQUIF TECHICAL IFORMATIO

More information

BIFURCATED AXIAL FLOW FANS

BIFURCATED AXIAL FLOW FANS AXIAL FLOW FANS HIGH PERFORMANCE, LOW MAINTENANCE, 'MOTOR OUT OF AIRSTREAM' FOR COMPLETE PEACE OF MIND. 292 29 285 8 BENEFITS HIGH TEMPERATURE PERFORMANCE The standard bifurcated unit is suitable for temperatures

More information

AXUS HIGH TEMPERATURE AXIAL FANS

AXUS HIGH TEMPERATURE AXIAL FANS WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS. 342 029 2085 8 BENEFITS TRIED & TESTED Nuaire s high temperature fans have been tested in accordance with the latest legislation and

More information

Terminator Input. (TIA) GRP Roof/Wall Input/Supply Fans. Installation and Maintenance

Terminator Input. (TIA) GRP Roof/Wall Input/Supply Fans. Installation and Maintenance Terminator Input (TIA) GRP Roof/Wall Input/Supply Fans The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU Introduction The units are manufactured in five fan sizes from 350mm dia to 630mm

More information

MARK TEN. Belt Drive Roof Mounted Extract Fans. Installation and Maintenance. Standby motor when fitted. Anti-vibration mountings

MARK TEN. Belt Drive Roof Mounted Extract Fans. Installation and Maintenance. Standby motor when fitted. Anti-vibration mountings MARK TEN elt Drive Roof Mounted Extract Fans Installation and Maintenance The EM Directive 2014/30/EU The Low Voltage directive 2014/35/EU Introduction Of monocoque construction and manufactured in aluminium

More information

QUIETSCROLL TWIN FAN RANGE

QUIETSCROLL TWIN FAN RANGE QUIETSCROLL TWIN FAN RANGE MOST COMPREHENSIVE RANGE OF TWIN FANS WITH INTEGRAL ENERGY- SAVING CONTROLS NUAIRE. FOR THE COMPLETE VENTILATION SOLUTION UK MADE QUIETSCROLL TWIN FANS QUIETSCROLL TWIN FAN RANGE

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

Terminator. TRA/TRM/TRC Roof Extract Fan. Installation and Maintenance

Terminator. TRA/TRM/TRC Roof Extract Fan. Installation and Maintenance Terminator TRA/TRM/TRC Roof Extract Installation and Maintenance The EMC Directive 2014/30/EU The ow Voltage directive 2014/35/EU Introduction The s are manufactured using a range of six basic cowl sizes

More information

SQUIF HIGH TEMPERATURE FANS

SQUIF HIGH TEMPERATURE FANS FNS HIGH TEMPERTURE CENTRIFUGL SQUIF FOR SMOKE EXTRCT CERTIFIED TO EN12101-3-2002. 366 029 2085 8200 BENEFITS HIGH TEMPERTURE PPLICTION Capable of running continuously at 90ºC, ideal for kitchen canopy

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling ROOF MOUNTED FNS Series Mixed Flow Fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements Range of roof mounted mixed flow fans supplied as standard for

More information

CONTROLS & ANCILLARIES ANCILLARIES COMMERCIAL & DOMESTIC TECHNIC AL INFORMATION ANCILLARIES ALL YOUR REQUIREMENTS FROM A SINGLE SUPPLIER.

CONTROLS & ANCILLARIES ANCILLARIES COMMERCIAL & DOMESTIC TECHNIC AL INFORMATION ANCILLARIES ALL YOUR REQUIREMENTS FROM A SINGLE SUPPLIER. ANCILLARIES COMMERCIAL & DOMESTIC ANCILLARIES ALL YOUR REQUIREMENTS FROM A SINGLE SUPPLIER. 424 029 2085 8200 ANCILLARIES COMMERCIAL & DOMESTIC BENEFITS EXTRACT GRILLES DIFFUSERS LOUVRES VOLUME & CONTROL

More information

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS. XBOXER THERMAL WHEEL HEAT RECOVERY UNITS HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS. 118 029 2085 8200 XBOXER THERMAL WHEEL BENEFITS HIGH EFFICIENCY Up to 85% efficient

More information

AXS. Installation and Maintenance. AXUS Swift Circular Long Cased Axial Flow Fans. 1.0 Introduction. 3.0 Installation And General Advice. 2.

AXS. Installation and Maintenance. AXUS Swift Circular Long Cased Axial Flow Fans. 1.0 Introduction. 3.0 Installation And General Advice. 2. .0 Introduction AXS The AXUS SWIFT range of axial flow fans are designed for in duct applications. Manufactured from galvanised steel, the units are suitable for indoor or outdoor installation and at any

More information

Wide performance ranges are obtained by using three impeller designs to suit all types of applications.

Wide performance ranges are obtained by using three impeller designs to suit all types of applications. Roof Mounted Fans Section 6 Wide performance ranges are obtained by using three impeller designs to suit all types of applications. The roof extract units are designed to satisfy the consultants functional

More information

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications. EuroSeries (ESR) Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 250 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm)

More information

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS External roof mounted single fan unit manufactured from aluzinc. 7.111 +44 (0) 29 2085 8515 BENEFITS Hard wearing on site External single fan unit manufactured

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

MIXVENT-TH Series Mixed Flow Fans

MIXVENT-TH Series Mixed Flow Fans ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans 0 021682 603075 P P L I T I O N S Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured

More information

3ph Belt Drive, Run & Standby, Roof & Plantroom Twinfans

3ph Belt Drive, Run & Standby, Roof & Plantroom Twinfans 3ph Belt Drive, Run & Standby, Roof & Plantroom Twinfans The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU EST-X C Removable top panel Commissioning box A 50mm Figure 1. EST*-X Plantroom/roof

More information

AXUS AXR. Roof Mounted Axial Fan for Smoke Control Installation and Maintenance. Handling

AXUS AXR. Roof Mounted Axial Fan for Smoke Control Installation and Maintenance. Handling AXUS AXR High Temperature 300 o C for 1hr, 400 o C for 2hrs Roof Mounted Axial Fan for Smoke Control Installation and Maintenance The EMC Directive 2014/30/EU The Low Voltage directive 2014/35/EU Introduction

More information

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling MIXVENT-TH ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured from high strength

More information

NALSF & NALSRF Belt Drive Roof and Plantroom Single Fans

NALSF & NALSRF Belt Drive Roof and Plantroom Single Fans NLSF & NLSRF elt Drive Roof and Plantroom Single Fans Installation and Maintenance The EM Directive 2014/30/EU The Low Voltage directive 2014/35/EU Introduction The Nuaire NLSF and NLSRF elt Drive Single

More information

Centrifugal Inline Fans

Centrifugal Inline Fans Centrifugal Inline Fans Models SQ-M and SQ-M Direct and elt Drive UILDING VLUE IN IR. February January 2018 2017 Models SQ-M & SQ-M Centrifugal Square Inline Duct Fans Designed for indoor and outdoor clean

More information

NALTF & NALTRF Belt Drive Roof and Plantroom Twinfans

NALTF & NALTRF Belt Drive Roof and Plantroom Twinfans NALTF & NALTRF Belt Drive Installation and Maintenance The EMC Directive 2014/30/EU The Low Voltage directive 2014/35/EU Introduction The Nuaire NALTF and NALTRF Belt Drive Twinfan range consists of the

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Uniclass L7534. Manufacture controlled to ISO9001

Uniclass L7534. Manufacture controlled to ISO9001 CABINET & TWIN FANS FOR INDUSTRIAL / COMMERCIAL USE "ACFS" - Quiet Duct Centrifugal - Single Fan "DMTSQ" - Quiet Duct Centrifugal - Twin Fan "RMS" - Roof Centrifugal - Single Fan "RMTS" - Roof Centrifugal

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

200mm - 760mm diameter Volume flow up to 9.2m 3 /s Static pressures up to 1000 Pa Four fan types allowing versatility of performance Rugged fibre glass construction casings Completely assembled units Mounting

More information

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

Installation and Maintenance

Installation and Maintenance Patent applied for. AIRE-VOLVE SINGLE FANS (AVS/AVSCP & AVS-A /AVS-ACP) Single Fans for indoor use Installation and Maintenance The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 Introduction

More information

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour 1.0 Introduction The Nuaire Axus range of Long Cased Axial Flow Fans are produced in sixteen case sizes from 315mm dia. to 1600mm dia. with duties up to 65m3/s. Impellers are manufactured in aluminium

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

ifan Copford Box Range

ifan Copford Box Range Setting the Standard for Energy Management ifan Copford Box Range Energy Management by demand Introduction The ifan is designed to offer environmental management through a controllable solution for the

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans ROOF MOUNTD FANS MAX-TMP Series, entrifugal 400 º/2h Rated Fans Description - Applications The MAX-Temp range of roof extract fans are available in horizontal (TH-THT) or vertical (TV-TVT) discharge formats,

More information

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Galaxy TM In-Line Belt Driven Twin Fans (GDB) Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features & Benefits In-line, Belt Driven, compact centrifugal twin fan High Quality Heavy Gauge Galvanised Steel Casing Optional IP65 Service Isolator Motor

More information

Compact Design BB101 & 93

Compact Design BB101 & 93 Acoustic Shield Natural Ventilation Acoustic Roof Vents Compact Design BB101 & 93 Standard / Twin Flow / Mixed Mode natural ventilation roof vents can be finished in any colour to compliment the architectural

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range Twin and Single Inline Fans Offers a range of flexible installation and application options, including auto-changeover on the Twin range 2 Version 3.1 Breathing Buildings Inline Box Fans Demand Control

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Product information - Version 3 DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Overskrift placering Table of contents Choice of motor... 4 DTV roof fans... 5 - Technical specifications

More information

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel ITEC High Efficiency EC Twin Fan for convenient fitting and full control Casing constructed from 1.6mm Galvanised sheet steel Circular spigot connection Inline for ease of fitting into duct system Single

More information

Acoustic Twin Fans (ATQ)

Acoustic Twin Fans (ATQ) Acoustic Twin Fans (ATQ) Features and Benefits Available in sizes from 100 to 500mm dia 50mm Acoustically treated housing, Class O rated, self extinguishing, zero burn rate, resists ignition, no toxic

More information

IN-LINE FANS COMMERCIAL VENTILATION

IN-LINE FANS COMMERCIAL VENTILATION www.vortice.com IN-LINE FNS OMMERIL VENTILTION HEDQURTERS VORTIE IN THE WORLD Founded in 1974, Vortice France is located at rétail about 1 Km from Paris. Our current Vortice Headquarters have been located

More information

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment Roof Extract Units Roof Units Specification The Flaktwoods Colchester range of roof extract units are designed to satisfy the consultants functional requirement for a direct drive fan unit of guaranteed

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000. Circular Box Fans - DAISHO EC Range Features 125mm to 1mm Air flow 1,25 m 3 /h (3.5m 3 /s) Static pressures up to 125 Pa Maximum temperature range 6ºC Suitable for variable or constant pressure systems

More information

CONTROLS & ANCILLARIES 409

CONTROLS & ANCILLARIES 409 409 FAN TYPE PAGE ECOSMART CONTROLS 410 OTHER CONTROLS 418 AIREMISER 421 ANCILLARIES 424 409 ECOSMART CONTROLS TECHNICAL INFORMATION ENERGY SAVING CONTROLS THE MOST FLEXIBLE ENERGY SAVING VENTILATION CONTROL

More information

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710. Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features and Benefits In-line, Belt Driven, compact centrifugal twin fan. High Quality Heavy Gauge Galvanised Steel Casing. Optional IP65 Service

More information

400mm - 630mm diameter Volume flow up to 7.2m 3 /s ASED 42 Static pressures up to 1000 Pa High energy efficiency All casings are hot dipped galvanised Low installed noise levels protection IP55 Overheat

More information

BELT DRIVEN CABINET FANS CVTT Series

BELT DRIVEN CABINET FANS CVTT Series Range of forward curved belt drive cabinet fans manufactured from galvanised steel sheet, internally lined with melamine thermo-acoustic insulation. ll models incorporate a double inlet low pressure centrifugal

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR 13 POWERBOX EC FANS - ESTOC EC FEATURES Sizes from 3 to 3 mm diameter Air flow up to.1 m 3 /s Static pressures up to Pa Controllable EC motors Multiple outlet orientations ELECTRICAL SUPPLY 22-2V/Hz/1f

More information

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A LD ir cooled water chillers with axial fans R410 222 LD LD water chillers are efficient, low-noise products designed for medium to large applications. They are suitable for generating chilled water at

More information

LC/SC. Long & Short Cased Axial Fans

LC/SC. Long & Short Cased Axial Fans LC/SC Long & Short Cased xial Fans LC/SC contents introduction features & benefits specification performance dimensional data mounting silencer data accessories inverters & DCV controllers additional

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant infinity AIR VENT T E C H N O L O G Y energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant INDEX Selection Chart Page 3 Internal & External Acoustic

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made

More information

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code Tubes and ox Fans Duct Fans - ESTOC EC Range Features Sizes from 55 to 6 mm diameter ir flow 19, m /h (4. m /s) Static pressures up to 84 Pa Maximum temperature up to 6 C Controllable external rotor motors

More information

ceiling & inline/cabinet ventilators

ceiling & inline/cabinet ventilators Air Moving Solutions. ceiling & inline/cabinet ventilators T-Series ( T TL ) CATALOG 4600 March 2012 Ceiling&InlineVentilators T-Series T TL Twin City Fan & Blower s T Series Ceiling and TL Series Inline/Cabinet

More information

Sky Wing. Contents. Power Roof Ventilator

Sky Wing. Contents. Power Roof Ventilator Power Roof Ventilator Contents Quick Guide... 14 General, Advantages of the... 15 Specification... 16 Technical Description of the... 17 LTSA Roof duct... 19 Electrical and Control Equipment, Control Functions...

More information

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE CIL - Centrifugal In-Line Fans SBAF - Slimbox Acoustic Fans ACF - Acoustic Cabinet Fans - Direct Drive ACFS - Super-Silent Acoustic Cabinet Fans

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

MOUNTING ARRANGEMENT OPTIONS OVERVIEW

MOUNTING ARRANGEMENT OPTIONS OVERVIEW ELT DRIVE SIDEWLL PROPELLER FNS MOUNTING RRNGEMENT OPTIONS OVERVIEW Page Mounting rrangement Description 2-3 Housing Heavy-gauge, all galvanized G-90 steel housing provides a simple solution to installing

More information

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE. NEW NSM ir/water chillers for outdoor installation with free cooling Screw compressors, shell and tube heat exchangers and axial fans from 306 2028kW 1402/9603 free cooling R134a HIGH EFFIIENY LSO T PRTIL

More information

Corrosion Resistant Polypropylene Fan Catalogue

Corrosion Resistant Polypropylene Fan Catalogue November 6 Edition Laboratory & Industrial Fume Extraction Corrosion Resistant Polypropylene Fan Catalogue www.axairfans.co.uk ...bout xair Fans UK pplication Knowledge : 20 years experience in general

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

Safety Lampholders and Pendants

Safety Lampholders and Pendants Safety Lampholders and Pendants Safety products are designed to make life easy for you. When the lamp is removed from the lamp holder body the power is automatically disconnected at the contacts - ensuring

More information

FIXED PITCH PROPELLER FANS

FIXED PITCH PROPELLER FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS FIXED PITCH PROPELLER FANS MODEL TCWP CATALOG AX500 DECEMBER 2012 PROPELLER FANS Model TCWP Fixed Pitch Heavy-Duty Construction Twin

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE 83 PLASTIC TUBE FANS - ESPADA FEATURES mm to 315 mm diameter Air flow up to.35 m 3 /s Static pressures up to 58 Pa Plastic cased centrifugal fan Low noise levels Corrosion resistant design Easy electrical

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS.

WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS. WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS. 342 02 205 BENEFITS TRIED & TESTED Nuaire s high temperature fans have been tested in accordance with the latest legislation and testing

More information

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX NA-NB NA-NB ENTRIFUGAL FANS STANDARD TEMPERATURES AND EX PRODUT FATS PRODUT The centrifugal fans type NA and NB are robust and versatile fans of the single-inlet type with backward-curved blades. APPLIATION

More information