Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Size: px
Start display at page:

Download "Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range"

Transcription

1 Twin and Single Inline Fans Offers a range of flexible installation and application options, including auto-changeover on the Twin range

2 2 Version 3.1

3 Breathing Buildings Inline Box Fans Demand Control Ventilation 3 Inline Box Fans with Demand Control Ventilation Designed for energy efficient supply or extract ventilation, our range of inline fans provide full Demand control ventilation. The inline fan range maintains low noise levels and is compact enough to be discreetly installed above a false ceiling or on the roof. The Twin models offer auto-changeover functionality for toilets and other rooms where % standby is required. Product Information Features Duct Sizes mm - Airflow.1 to 1.6m 3 /s, Pressure up to 6Pa Demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc construction suitable for internal or external mounting Manufactured controlled to BS EN ISO 91 tested to BS848 Part 1 & 2 Available as single or twin fan models Twin fans incorporate duty sharing auto changeover control as standard Product Description Available as single or twin models and internally treated with O Class rated acoustic foam for high sound absorption. Weatherproof external units incorporate an additional controller shroud. The housing is designed to be as compact as possible for concealed false ceiling applications. The unit is suitable for ceiling or floor mounting, non-return dampers can be easily rotated on site to suit. Controls Hierarchical Control The system is controlled by on-board electronics, with an LCD display showing fan status and allowing for simple commissioning and installation, whether as a local sensor control unit or linked into a building management system. 1. Switched on/off or minimum/maximum level control. In an environment such as an office the system is activated and runs between minimum and maximum levels by a choice of sensors. AQS Air Quality Sensor PIR Detector Thermostat Humidistat Time Clock BMS (remote enable) 2. Hierarchical maximum demand multi-sensor input. Used with a combination of sensors, with a defined level of priorities to simultaneously control a number of atmospheric conditions within a room, such as a meeting room. CO 2 /temperature room mounted CO 2 duct mounted Manual speed adjuster Building Management System (-1V)

4 4 Inline Box Fans with Demand Control Ventilation Construction and Impellers All units feature a low energy, Class 1, EC/DC external rotor motor and backward curved impeller assembly specifically chosen for performance and non-overloading characteristics. The assembly is dynamically balanced to DIN ISO 194 Grade 6.3. Models with a duct size of mm are rated IP54, all other sizes are rated IP44 according to BS EN Ball bearings are greased for life. Insulation is Class B (from - C to +6 C). All models incorporate internal electronic overload protection and soft start function. Electrical Every unit is fitted with a purpose designed PCB controller with alphanumerical display and 4 button membrane keypad for fan status & commissioning set up. The enclosure is fitted with a 4-pole 1A isolator that is suitable for fitting a locking device to prevent accidental operation. The twin unit controller features automatic 6hr duty/share and run/standby in the event of motor failure. s are single phase 23V +/- 1% / /6Hz / 1ph (size -mm) or V +/- 1% / /6Hz / 3ph (size mm), (4 wire systems only). 24V DC power is provided from the controller for powering the matched range of switches and sensors. Sound Extensively tested to BS848 parts 1 & 2. Published db(a) figures are free field sound pressure levels at with spherical propagation at reference level of 2x1-5 Pa. The inlet/outlet sound power level spectra figures are db with a reference of 1 12 Watts. System Overview The system is made up of 3 parts: EC/DC Fan, Integral Control Unit, Sensors and Controls. The ventilation demands of the room are detected by the wall, ceiling or duct mounted sensors/switches. These communicate with the control unit, which in turn drives the fan to the required speed to deliver the airflow. As the ventilation is provided to the room the sensors continuously feedback to the control unit, driving the fan motor to the exact level required in the room at any one time. System Technology Demand ventilation is a closed loop controlled ventilation system. Employing a range of sensors to manage the system, demand is sensed by PIR, temperature, humidity, air quality or carbon dioxide sensors. Depending on the levels in the rooms, fan speed is ramped up or down to control

5 Breathing Buildings Inline Box Fans Demand Control Ventilation 5 the parameters within the required limits. If the room is unoccupied, the system switches off, saving energy and cost to the business. Available in single or twin fan configurations, with twin allowing for load sharing or standby for extra reliability. EC/DC Energy Saving Fan Technology These fans utilise the latest EC/DC motor technology, which provides energy saving benefits even over DC motors. This technology is also infinitely speed controllable and offers increased energy savings across the complete speed control range when compared with conventional inverter drive solutions. The result is higher efficiency, reduced noise, accurate controllability, better speed control drawing less power and as a result better overall system performance. The unit is designed for use in a hierarchal system where maximum demand, for example temperature and/or CO 2 gives priority control of the fan speed.

6 6 Inline Box Fans Demand Control Ventilation - Single MV - -IL Dimensions (mm) AIRFLOW H SPIGOT C OFFSET L C D E G A F B Weight Model A B C D E F G H kg MV-IL MV12-IL MV1-IL MV-IL MV-IL MV315-IL MV-IL MV-IL

7 Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 7 MV - -IL Accessories Model Flex connection A/V mounts Duct heater (electric) Attenuator (9mm) MV-IL FLEX AVM HTR ATT MV12-IL FLEX1 AVM HTR12 ATT12 MV1-IL FLEX1 AVM HTR1 ATT1 MV-IL FLEX AVM HTR ATT MV-IL FLEX AVM HTR ATT MV315-IL FLEX315 AVM HTR315 ATT315 MV-IL FLEX AVM HTR ATT MV-IL FLEX AVM HTR ATT Model In-room CO 2 sensor In-duct CO 2 sensor PIR MV-IL 11 Duct CO2 PIR MV12-IL 11 Duct CO2 PIR MV1-IL 11 Duct CO2 PIR MV-IL 11 Duct CO2 PIR MV-IL 11 Duct CO2 PIR MV315-IL 11 Duct CO2 PIR MV-IL 11 Duct CO2 PIR MV-IL 11 Duct CO2 PIR

8 8 Inline Box Fans Demand Control Ventilation - Single MV-IL Pressure (Pa) % 4 % % % Air Volume (m 3 /s) phase m³/s.4 1 SFP.18 Watts.1 m³/s SFP Watts m³/s SFP Watts m³/s SFP Watts k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

9 Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 9 MV12-IL Pressure (Pa) % % 4 % % Air Volume (m 3 /s) phase m³/s.5 1 SFP.14 Watts.1 m³/s SFP Watts m³/s SFP Watts m³/s SFP Watts k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

10 1 Inline Box Fans Demand Control Ventilation - Single MV1-IL 7 % % % % phase m³/s.5 1 SFP.14 kw.1.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

11 Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 11 MV-IL 7 % 4 % % % phase 7 m³/s.6 1 SFP.13 kw.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

12 12 Inline Box Fans Demand Control Ventilation - Single MV-IL 7 7 Sentinel Single Fan % % % % 4 % % % Phase phase m³/s m³/s SFP SFP kw kw.1.1 m³/s m³/s SFP SFP kw kw m³/s m³/s SFP SFP kw kw m³/s m³/s SFP SFP kw kw % Absorbed Power kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

13 Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 13 MV315-IL % % % % phase m³/s.12 1 SFP.6 kw.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

14 14 Inline Box Fans Demand Control Ventilation - Single MV-IL 7 % % % % phase m³/s.24 1 SFP.7 kw.2 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

15 Breathing Buildings Inline Box Fans Demand Control Ventilation - Single 15 MV-IL 7 % % % % phase 7 m³/s SFP.8.18 kw.4.4 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

16 16 Inline Box Fans Demand Control Ventilation - Twin TMV - -IL Dimensions (mm) Ø C E D G A F B Model Duct diameter mm a b c d e f g Weight Kg TMV-IL TMV12-IL TMV1-IL TMV-IL TMV-IL TMV315-IL TMV-IL TMV-IL

17 Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin 17 TMV - -IL Accessories Model Flex connection A/V mounts Attenuator (9mm) TMV-IL FLEX AVM ATT TMV1-IL FLEX1 AVM ATT12 TMV1-IL FLEX1 AVM ATT1 TMV-IL FLEX AVM ATT TMV-IL FLEX AVM ATT TMV315-IL FLEX315 AVM ATT315 TMV-IL FLEX AVM ATT TMV-IL FLEX AVM ATT Model Temperature & CO 2 sensor Duct CO 2 sensor PIR TMV-IL 11 Duct CO2 PIR TMV1-IL 11 Duct CO2 PIR TMV1-IL 11 Duct CO2 PIR TMV-IL 11 Duct CO2 PIR TMV-IL 11 Duct CO2 PIR TMV315-IL 11 Duct CO2 PIR TMV-IL 11 Duct CO2 PIR TMV-IL 11 Duct CO2 PIR

18 18 Inline Box Fans Demand Control Ventilation - Twin TMV-IL 7 % % % % phase m³/s SFP.3.9 kw.1.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

19 Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin 19 TMV12-IL Guide % % % % phase m³/s.4 1 SFP. kw.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

20 2 Inline Box Fans Demand Control Ventilation - Twin TMV1-IL % % % % phase m³/s.4 1 SFP.23 kw.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw t k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

21 Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin 21 TMV-IL 7 % % % % phase 7 m³/s.5 1 SFP.2 kw.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

22 22 Inline Box Fans Demand Control Ventilation - Twin TMV-IL 7 % % % % phase m³/s.5 1 SFP.18 kw.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

23 Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin 23 TMV315-IL Guide 7 4 % % % % phase m³/s.9 1 SFP.11.9 kw.1 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

24 24 Inline Box Fans Demand Control Ventilation - Twin TMV-IL 7 % % % % phase m³/s.16 1 SFP.13 kw.2 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

25 Breathing Buildings Inline Box Fans Demand Control Ventilation - Twin TMV-IL 7 % % % % phase m³/s SFP kw.5.4 m³/s SFP kw m³/s SFP kw m³/s SFP kw k 2k 4k 8k Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet Breakout Inlet Outlet

26 Contact us: w: e: t: f: a: 15 Sturton Street Cambridge CB1 2SN skype:

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range

More information

Acoustic Twin Fans (ATQ)

Acoustic Twin Fans (ATQ) Acoustic Twin Fans (ATQ) Features and Benefits Available in sizes from 100 to 500mm dia 50mm Acoustically treated housing, Class O rated, self extinguishing, zero burn rate, resists ignition, no toxic

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features and Benefits In-line, Belt Driven, compact centrifugal twin fan. High Quality Heavy Gauge Galvanised Steel Casing. Optional IP65 Service

More information

QUIETSCROLL TWIN FAN RANGE

QUIETSCROLL TWIN FAN RANGE QUIETSCROLL TWIN FAN RANGE MOST COMPREHENSIVE RANGE OF TWIN FANS WITH INTEGRAL ENERGY- SAVING CONTROLS NUAIRE. FOR THE COMPLETE VENTILATION SOLUTION UK MADE QUIETSCROLL TWIN FANS QUIETSCROLL TWIN FAN RANGE

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS Cabinet Fan SV-1 INDEX INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART pages 01 02 03 04 DIMENSION SHEET - SINGLE CABINET FANS DIMENSION SHEET - TWIN CABINET FANS PERFORMANCE GRAPH WIRING

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION TWI FAS TWI SQUIF TECHICAL IFORMATIO TWI SQUIF FAS RU & STADBY SOLUTIO FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIOS. FOR HIGH TEMPERATURE RAGE REFER TO SMOKE SECTIO 264 TWI FAS TWI SQUIF TECHICAL IFORMATIO

More information

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Galaxy TM In-Line Belt Driven Twin Fans (GDB) Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features & Benefits In-line, Belt Driven, compact centrifugal twin fan High Quality Heavy Gauge Galvanised Steel Casing Optional IP65 Service Isolator Motor

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710. Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable

More information

BOX BLB Centrifugal Box Fan

BOX BLB Centrifugal Box Fan Centrifugal Box Fan Select models available for next day delivery Product Overview 3 sizes from 260mm to 400mm Air volume flow rates up to 0.751m³/s Static pressures up to 733 Pa Suitable for operating

More information

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel ITEC High Efficiency EC Twin Fan for convenient fitting and full control Casing constructed from 1.6mm Galvanised sheet steel Circular spigot connection Inline for ease of fitting into duct system Single

More information

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS SOUND-INSULATED FANS Series Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7 m 3 /h Purpose KSB fan design allows to use them in supply and exhaust ventilation systems

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications. EuroSeries (ESR) Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 250 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm)

More information

TWINFLOW STDR Product Brochure

TWINFLOW STDR Product Brochure TWINFLOW STDR Brochure Available for next day delivery with ELTA SELECT Direct Drive Twin Centrifugal Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

ifan Copford Box Range

ifan Copford Box Range Setting the Standard for Energy Management ifan Copford Box Range Energy Management by demand Introduction The ifan is designed to offer environmental management through a controllable solution for the

More information

BATHROOM EXTRACT FANS DECOR-100 Series

BATHROOM EXTRACT FANS DECOR-100 Series DECOR-1 Series Range of axial extractors with airflow rates of 1 m 3 /h, for connection to 1 mm diameter circular ducting. All the fans are manufactured from injection moulded plastic, fitted with neon

More information

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 HRH High efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4.3 m³/h The HRH units have been designed for non-residential applications for which a forced and

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series TD-SILENT ECOWATT - MODELS 5 to TD-SILENT ECOWATT - MODELS AND At 5% of full speed fan power consumption is reduced by 7% Low profile Mixed-flow fans with sound-absorbent insulation, extremely quiet, fan

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant infinity AIR VENT T E C H N O L O G Y energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant INDEX Selection Chart Page 3 Internal & External Acoustic

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Square Duct Fans - ESTOC TARGE Range Features Sizes from 55 to 6 mm diameter Air flow 21, m /h (5.8 m /s) Static pressures up to 145 Pa Maximum temperature up to 11 C Controllable external rotor motors

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000. Circular Box Fans - DAISHO EC Range Features 125mm to 1mm Air flow 1,25 m 3 /h (3.5m 3 /s) Static pressures up to 125 Pa Maximum temperature range 6ºC Suitable for variable or constant pressure systems

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

Uniclass L7534. Manufacture controlled to ISO9001

Uniclass L7534. Manufacture controlled to ISO9001 CABINET & TWIN FANS FOR INDUSTRIAL / COMMERCIAL USE "ACFS" - Quiet Duct Centrifugal - Single Fan "DMTSQ" - Quiet Duct Centrifugal - Twin Fan "RMS" - Roof Centrifugal - Single Fan "RMTS" - Roof Centrifugal

More information

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE CIL - Centrifugal In-Line Fans SBAF - Slimbox Acoustic Fans ACF - Acoustic Cabinet Fans - Direct Drive ACFS - Super-Silent Acoustic Cabinet Fans

More information

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 Ceiling or wall mounting extract ventilation Extract ventilation through wall or using a shunt duct system All V models incorporate all accessories

More information

SILENT MV Ultra Quiet In-line Fans

SILENT MV Ultra Quiet In-line Fans Ultra Quiet In-line Fans 5 IP44 2 YEAR GUARANTEE Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR 13 POWERBOX EC FANS - ESTOC EC FEATURES Sizes from 3 to 3 mm diameter Air flow up to.1 m 3 /s Static pressures up to Pa Controllable EC motors Multiple outlet orientations ELECTRICAL SUPPLY 22-2V/Hz/1f

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

QUBE SQU-HT(S) Product Brochure

QUBE SQU-HT(S) Product Brochure QUBE SQU-HT(S) Product Brochure Available for next day delivery with ELTA SELECT Centrifugal Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy

More information

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW: VHR Void Mounted Heat Recovery Units TM.72 W/I/s TOTAL SFP Typical General: Units shall be manufactured from high quality galvanized sheet steel with stainless steel drain trays, acoustic, non-hygroscopic

More information

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS. XBOXER THERMAL WHEEL HEAT RECOVERY UNITS HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS. 118 029 2085 8200 XBOXER THERMAL WHEEL BENEFITS HIGH EFFICIENCY Up to 85% efficient

More information

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION HT Er 1253 ENTRFUGAL N-LNE FANS ALATON entrifugal in-line fans for vertical or horizontal installation, suitable to extract air in residential, commercial, agricultural and industrial buildings such as

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code Tubes and ox Fans Duct Fans - ESTOC EC Range Features Sizes from 55 to 6 mm diameter ir flow 19, m /h (4. m /s) Static pressures up to 84 Pa Maximum temperature up to 6 C Controllable external rotor motors

More information

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

TD-ECOWATT AND DECOR-ECOWATT Series

TD-ECOWATT AND DECOR-ECOWATT Series S&P presents its new ranges of domestic and commercial fans with DC motors TD-ECOWATT AND DECOR-ECOWATT Series Up to 55% savings in energy consumption Reduced CO 2 emissions Improvement of the environment

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

TD-SILENT Series (160 to 1000 models)

TD-SILENT Series (160 to 1000 models) IN-LINE MIXED LOW DUT ANS ultra-quiet Series (1 to models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-3, TD-, TD-8 and

More information

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers. ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS External roof mounted single fan unit manufactured from aluzinc. 7.111 +44 (0) 29 2085 8515 BENEFITS Hard wearing on site External single fan unit manufactured

More information

AXUS HIGH TEMPERATURE AXIAL FANS

AXUS HIGH TEMPERATURE AXIAL FANS WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS. 342 029 2085 8 BENEFITS TRIED & TESTED Nuaire s high temperature fans have been tested in accordance with the latest legislation and

More information

ZOO FAN SDF Destratification Ceiling Mounted Fan

ZOO FAN SDF Destratification Ceiling Mounted Fan Destratification Ceiling Mounted Fan Overview 2 standard sizes from 250mm to 300mm Air volume flow rates up to 0.593m³/s (AC) and 0.656m³/s (EC) High quality Ziehl-Abegg FE2owlet impeller Suitable for

More information

WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS.

WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS. WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS. 342 02 205 BENEFITS TRIED & TESTED Nuaire s high temperature fans have been tested in accordance with the latest legislation and testing

More information

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series False-ceiling models CADB/T-HE 4 to 33 Heat Recovery Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised

More information

Sapphire Horizontal Waterside Control Fan Coil Units

Sapphire Horizontal Waterside Control Fan Coil Units Sapphire Horizontal Waterside Control Fan Coil Units Introduction The Quartz SAPPHIRE series is a compact, high output fan coil unit capable of meeting exacting heating and cooling requirements whilst

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

Series VTI Quiet Cased Twin Extract Fan Unit

Series VTI Quiet Cased Twin Extract Fan Unit AIR HANDLERS LTD Series VTI Quiet Cased Twin Extract Fan Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers have been trading since May

More information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

Compact Design BB101 & 93

Compact Design BB101 & 93 Acoustic Shield Natural Ventilation Acoustic Roof Vents Compact Design BB101 & 93 Standard / Twin Flow / Mixed Mode natural ventilation roof vents can be finished in any colour to compliment the architectural

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency. CPD7948/075 Specification Oil-Free, Air Cooled, Rotary Screw Compressors - Dryclon Range Models D75, D90, D110, D132, D150 (50Hz) D55, D75, D90, D110, D150 (60Hz) COMPRESSOR PACKAGE An enclosed two stage

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

Centrifugal fan with highly efficient EC drive motor

Centrifugal fan with highly efficient EC drive motor Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany

More information

BIFURCATED AXIAL FLOW FANS

BIFURCATED AXIAL FLOW FANS AXIAL FLOW FANS HIGH PERFORMANCE, LOW MAINTENANCE, 'MOTOR OUT OF AIRSTREAM' FOR COMPLETE PEACE OF MIND. 292 29 285 8 BENEFITS HIGH TEMPERATURE PERFORMANCE The standard bifurcated unit is suitable for temperatures

More information

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/ General Characteristics Model Name AJD 33 Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model JOHN DEERE 3029DF128 Alternator Made and Model ECP 28-VL/4 A Control Panel Model 7320 Canopy AK 20 Power

More information

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GENERAL VENTILATOR A quality product suitable for general residential application. proprietary made and compact design fan is designed

More information

MULTIFLOW SEL Product Brochure

MULTIFLOW SEL Product Brochure MULTIFLOW SEL Product Brochure Available for next day delivery with ELTA SELECT Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency

More information

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling ROOF MOUNTED FNS Series Mixed Flow Fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements Range of roof mounted mixed flow fans supplied as standard for

More information

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes Product information - Version 4 BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes Table of contents Economic considerations... 4 Choice

More information

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h MIRUENT Power roof ventilator with 27 different airflow variants up to 24, m 3 /h General MIRUENT is a power roof ventilator with a casing made of corrosion-resistant aluminium The power roof ventilator

More information

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

KVAR POWERHOUSE RANGE 140 KVA 200 KVA KVAR POWERHOUSE RANGE 140 KVA 200 KVA 50 hz Three phase - 415 v Model Engine Manufacturing Alternat PRP Output ESP Output country of engine or and alternator Kva Kw Kva Kw PM140 1106A-70TG1 ECP34-2L UK

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

In-line rectangular fans. Technical Catalogue

In-line rectangular fans. Technical Catalogue In-line rectangular fans Technical Catalogue Overview IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning

More information

ISEO IMF Product Brochure

ISEO IMF Product Brochure ISEO IMF Product Brochure Available for next day delivery with ELTA SELECT In-Line Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy

More information