PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
|
|
- George Wiggins
- 5 years ago
- Views:
Transcription
1 TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor Fans Louvre Outdoor Coil Guard Pre-charged with R410A Refrigerant Adaptive Demand Defrost UNIT OPTIONS Low Ambient Compressor Soft Starters Phase Protection Additional Full Coil Coat Protection Fault Detection Board CONTROL OPTIONS ActronAir C7-4 (BCA Compliant) 7-Day Programmable Controller with 2 Events/Day Temperature Set Back and After Hours Timer Zone Kit for Control up to 4 Zones (See Control Section) Auto, Heat & Cool Modes Auto/Continuous Indoor Fan Operation 2 Speed Indoor Fan Setting Hot Start Feature 2 Stage Cooling/Heating with 3rd Stage Boost Heat Manual Control Inputs Remote Temperature Sensors 24-Hour ON/OFF Timer Home/Building Automation ON/OFF Capability UNIT LIANCE MEPS 12 Demand Response AS PACKAGE MODEL TOTAL* NETT** COOLING CAPACITY (kw) *** SENSIBLE CAPACITY (kw) *** HEATING CAPACITY (kw) ^ COOLING INPUT POWER (kw) ^^ HEATING INPUT POWER (kw) ^^ EER COP FLOW (l/s) - MIN. / NOMINAL / MAX. ^^^ 1462 / 17 / 1892 SOUND PRESS. 3M db(a) - LOW / HIGH 58.8 / 62.8 SOUND POWER LEVEL db(a) -- LOW / HIGH 75.8 / 79.8 POWER 415V / 3Ph+N / Hz RATED LOAD AMPS ** 23.4 FULL LOAD AMPS ^^^^ 31.4 CIRCUIT BREAKER AND CABLE AMPS 32.0 APPROXIMATE STARTING AMPS 64.0 WEIGHT (kg) 0 * Based on unit rating excluding indoor fan kw. ** Measured and tested in accordance with AS/NZS *** At 27 0 C DB / 19 0 C WB entering air temperatures and 35 0 C ambient. ^ At 0 C DB entering air temperature and 7 0 C DB / 6 0 C WB ambient. ^^ input power includes indoor fan kw. ^^^ Max. - Min. airfl ow application range. ^^^^ Full Load Amps are based on compressor and fan motors maximum expected current. See Specifi cations sheet for cable size and circuit breaker size details. Note: Use input power to estimate running cost P
2 CAPACITY SELECTION DATA COOLING PERFORMANCE ENTERING TOTAL TOTAL SENSIBLE CAPACITY - kw CAPACITY AT DB TEMPERATURE ONTO COIL - 0 C DB - 0 C WB - 0 C kw HEATING PERFORMANCE WB TEMP ON OD COIL- 0 C HEATING CAPACITY - kw AT DB ENTERING - 0 C TH IH TH IH TH IH TH IH TH IH TH - Total Heating Capacity (kw). IH - Integrated Heating Capacity (kw) Includes defrost losses. FLOW CORRECTION MULTIPLIER % VARIATION -15% -10% -5% NOMINAL +5% +10% FLOW (l/s) TOTAL COOLING SENSIBLE COOLING HEATING FACTOR No allowance has been made for the effect of indoor fan motor. 2. Selection tables are based on nominal airfl ows. Correction factors must be applied for selection away from these conditions. ActronAir is constantly seeking ways to improve the design of it s products, therefore specifications are subject to change without notice. Please check prior to purchase P
3 DIMENSIONS AND CURVE U PACKAGE UNIT - STANDARD MODEL COIL 4 OVERALL NOMINAL DIMENSION (H x W x L) = 1330 x 1875 x 1590 DUCT (H x W) = 300 x 1065 RETURN DUCT = 525 x 14 USE M12 BOLT FOR FEET MOUNTING 1590 POWER ENTRY 40mm, 25mm THIRD ANGLE 1. All dimensions are in mm unless specifi ed. PROJECTION 2. Do not scale drawing. 3. Optional Anti-Corrosive Acrylic Coated Coil available on all units. COIL 30 OUTLET INLET RETURN INLET UNIT CURVE * EXTERNAL STATIC PRESSURE (Pa) Performance Fan Curve shown * is at Dry Coil Condition for 9x9 S W - Twin Deck Fan. FLOW (l/s) APPLICATION RANGE P
4 SOUND DATA Outdoor Radiated Sound Power Level (SWL) Fan Speed Sound Power Level db(a) Octave Band Centre Frequency (Hz), db k 2k 4k 8k Low High Indoor Outlet Sound Power Level (SWL) Airfl ow Setting Airflow Li/s Sound Power Level db(a) Octave Band Centre Frequency (Hz), db k 2k 4k 8k Nominal RADIATED OUTLET Sound Power Level Sound Power Level Octave Band Sound Power Level (db) Octave Band Sound Power Level (db) Low High k 2k 4k 8k 40.0 Nominal k 2k 4k 8k Octave Band Centre Frequency (Hz) Octave Band Centre Frequency (Hz) 1. Radiated sound power levels are based on ISO Outlet sound power levels are based on ISO ActronAir is constantly seeking ways to improve the design of it s products, therefore specifications are subject to change without notice. Please check prior to purchase P
5 SPECIFICATIONS CONSTRUCTION CABINET BASE CABINET TOP AND SIDES SURFACE FINISH 1.6 mm Galvanized Steel mm ZA & Galv. Steel 65 microns Baked Polyester Powder Coat RESSOR NUMBER PER UNIT x TYPE 2 x Scroll (Hermetic) FULL LOAD AMPS 19.4 LOCKED ROTOR AMPS 64.0 STARTING METHOD D.O.L. (optional soft starter) INSULATION TYPE 10 mm Foil Faced Polyethylene mm Expanded Polystyrene REFRIGERATION SYSTEM REFRIGERANT TYPE EXPANSION CONTROL R-410A Direct Expansion Orifi ce SOUND LEVEL * db(a) SOUND PRESS. - Low / High 58.8 / 3m Distance SOUND POWER LEVEL - Low / High 75.8 / 79.8 * Sound data are based on outdoor fan s manufacturer sound level data. FACTORY CHARGE (grams) FILTER DRIER CONNECTION SIZE & TYPE FACTORY SUPPLIED / FITTED 6,910 per stage (per compressor) 9.52 mm (3/8 ) ODF Soldered Bi-Flow No ELECTRICAL See Installation Section for complete Filter Drier specifi cations. POWER - Hz 415 Volts x 3 Phase + Neutral VOLTAGE RANGE (min - max) 400V - 440V FULL LOAD AMPS * - Phase FULL LOAD AMPS * - Phase 2 & & 22.4 RATED LOAD AMPS** 23.4 PROTECTION DEVICES HIGH PRESSURE CUTOUT SWITCH LOW PRESSURE CUTOUT SWITCH RESSOR MOTOR TEMP. OVERLOAD Nonadjustable (Automatic Reset) Nonadjustable (Automatic Reset) Internal Thermal Cut-Out Internal Thermal Cut-Out APPROX. STARTING AMPS 64.0 OVERLOAD Internal Thermal Cut-Out IP RATING IP44 SUMP HEATER WATTS 2 x 30 W during Comp. Off Cycle IMPORTANT - The local electricity authority may require limits on starting current and voltage drop, please check prior to purchase. * Full Load Amps are based on compressor and fan motor s maximum expected current. ** Rated Load Amps are measured and tested in accordance with AS/NZS CABLE SIZE & CIRCUIT BREAKER SIZE Suggested minimum cable size should be used as a guide only, refer to AS/NZS 3000 Australian/New Zealand Wiring Rules for more details. CABLE SIZE (MAIN LINE) 6.0mm 2 (SUGGESTED MINIMUM) CIRCUIT BREAKER SIZE - AMPS 32.0 ELECTRIC CONTROLS DEFROST METHOD DEFROST TYPE CONTROL CIRCUIT BREAKER CONTROL FIELD WIRING Reverse Cycle Adaptive Demand Defrost 16.0 Amps 2 Core 14 / 0. Screened Cable OPERATING RANGE It is essential that the unit is correctly sized for the application and operates within its recommended range of operating conditions as shown below. COIL TUBE TYPE Copper - Rifl e Bore FIN TYPE Aluminium - Wave FACE AREA (m sqr) 2.46 Cooling MODE RANGE INTAKE TEMPERATURE INTAKE TEMPERATURE Max. 29 o C DB / 19 o C WB o C DB Min. o C DB / 15 o C WB 15 o C DB FIN SPACING (per m) 472 COIL COATING Blue Hydrophilic Coil Fin Protection ROWS --- NUMBER OF S x TYPE 2 x Axial NUMBER OF BLADES PER 4 DIAMETER (mm) 5 OUTPUT kw 0.37 MOTOR TYPE / DRIVE TYPE 6 Pole External Rotor / Direct Drive SPEED CONTROL 2 Speed via Capacitor The standard type outdoor fans fi tted to this unit will only accept Pa of external static resistance. COIL Max. 24 o C DB 21 o C DB / 16 o C WB Heating Min. 16 o C DB -10 o C DB IMPORTANT - For low ambient cooling use option S. Lower ambient available on request. Contact your nearest ActronAir offi ce for more details. Low Ambient Cooling Option S On Request Max. 29 o C DB / 19 o C WB o C DB Min. o C DB / 15 o C WB 5 o C DB Max. 29 o C DB / 19 o C WB o C DB Min. o C DB / 15 o C WB -5 o C DB TUBE TYPE Copper - Rifl e Bore FIN TYPE Aluminium - Louvre FACE ARE (m sqr) 0.86 FIN SPACING (per m) 472 ROWS --- NUMBER OF S x TYPE 1 x Twin Deck Centrifugal Fan DIAMETER / WIDTH (mm) 240 x 240 OUTPUT kw / INPUT kw 1.10 / 1.72 MOTOR TYPE / DRIVE TYPE 3 Speed 4 Pole / Direct FILTERS All return air including fresh air must have adequate fi lters supplied and fi tted by the installing contractor. Filters must be located in accessible location between the return air grille and the unit.- ActronAir does not supply or make any provisions for return air fi lter P
6 WIRING DIAGRAM ActronAir is constantly seeking ways to improve the design of it s products, therefore specifications are subject to change without notice. Please check prior to purchase. WD
7 UNIT DIMENSIONS PCA340V V PACKAGE UNIT - WITH COIL VERTICAL DISCHARGE COIL 4 OVERALL NOMINAL DIMENSION (H x W x L) = 1330 x 1875 x 1590 DUCT (H x W) = 300 x 1065 RETURN DUCT (H xw) = 525 x 14 USE M12 BOLT FOR FEET MOUNTING 1590 POWER ENTRY 40mm, 25mm 300 COIL 285 TOP VIEW 30 OUTLET INLET RETURN INLET FRONT VIEW 1515 SIDE VIEW SERVICE ACCESS AREAS GG 800 mm SERVICE CLEARANCE (. & ELECT. CTRL) AA BB 7 mm SERVICE CLEARANCE & FLOW ALLOWANCE HH COIL COIL EE DD 300 mm FLOW ALLOWANCE THIRD ANGLE 1. All dimensions are in mm unless specifi ed. PROJECTION 2. Do not scale drawing. 3. Refer Pipe Connection Details on Specifi cations Sheet. 4. Optional Anti-Corrosive Acrylic Coated Coil available on all units. 5. Suggested Service Clearance and Airfl ow Allowances are based on conditions that the spaces are free from obstructions and walkway passage of 1000mm is available. 6. Minimum service access areas are responsibilities of the installer. CC COIL DUCT WORK FF HEIGHT CLEARANCE = 10 PCA340V-00 - P
SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE
TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with
More informationTRI-CAPACITY PACKAGE UNIT
TECHNICAL SELECTION TRI-CAPACITY PACKAGE UNIT +50 o C -10 o C 3 THREE PHASE TRI-CAPACITY EC PLUG FAN LOUVRE LOW NOISE FAN UNIT FEATURES Compliant Scroll Compressors Tri-Capacity 33% 67% 100% Capacity Stages
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9
More informationFrom domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.
PRODUCT RANGE PRODUCT Contents RANGE Wall Hung Split Systems Variable Capacity Pages 4- Split Ducted Standard Cycling Pages 6-11 The ActronAir range of air conditioners provides a solution for most applications.
More informationAir Cooled Packaged Units
Air Cooled Packaged Units Technical Data OPA 465, OPA 550, OPA 705, OPA 855, OPA 960 (ECO) Cooling Capacity 44.9kW - 96.0kW Heating Capacity 41.1kW - 90.0kW Contents OPA 465 960 ECO 3 General 3 Applications
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS
Ducted Split System Air Conditioners Technical Data ISDL Series Optional HAN-L6 Controller Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 2.9 kw 1. kw JANUARY 5 ISDL SERIES DUCTED SPLIT
More informationDRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw
DRAFT Ducted Three Phase Packaged Air Conditioners Technical Data 96 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil OPTION TZT-71 Controller & Digital Scroll Compressor for close
More informationLandmark Rooftop Packaged Units
Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop
More informationCompresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW
Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,
More informationAFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components
AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free
More informationHPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM
1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationThe ActronAir range of air conditioners provides a solution for most applications.
Contents Icons Fan Type Fan Type Ability to vary the capacity of a compressor, allowing better temperature control and operating costs, whilst reducing energy consumption. Centrifugal Fan Centrifugal forward
More informationNSW/ACT QLD VIC/TAS SA/NT
PRODUCT Contents RANGE Icons Fan Type Fan Type Ability to vary the capacity of a compressor, allowing better temperature control and operating costs, whilst reducing energy consumption. Centrifugal Fan
More informationAir-Cooled Liquid Chiller with integrated hydraulic module
Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800
More informationGUIDE SPECIFICATIONS CE Series Two Stage R-410A
GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall
More informationVARIABLE CAPACITY COMMERCIAL SERIES Premium performance, flexible controls.
Commercial Premium performance, flexible controls. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. Advanced performance with flexible options. The year 1984
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationFDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E
R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationNOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)
NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor
More informationChiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.
Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationAir Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.
Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationT-Class Split System Units R-410A - 50 HZ
E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S TS T-Class Split System Units R-40A - 50 HZ Bulletin No. 49035 February 200 Supersedes October 2009 MODEL NUMBER IDENTIFICATION Nominal Capacity
More informationSLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw
Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features
More information2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C
P A C K A G E D E L E C T R I C / E L E C T R I C 2SA13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210454 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity
More informationNSW/ACT QLD VIC/TAS SA/WA/NT
PRODUCT Contents RANGE Icons 0 Innovation Fan Type Fan Type Wall Hung Split Systems Variable Capacity Pages - Split Ducted Cycling Split Ducted Variable Capacity Split Ducted Tri-Capacity Package Units
More informationGUIDE SPECIFICATIONS. ES Series R-410A
GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter
More informationPRODUCT RANGE. Trade, Sales and Technical Support Enquiries Service and Warranty Enquiries
Copyright 0 Actron Engineering Pty Limited ABN 00 6 0. Registered Trade Marks of Actron Engineering Pty Limited. Actron Engineering Pty Limited has applied for the registration of the Trade Marks Hercules,
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology
More informationACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)
-P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air
More informationDucted Split System Air Conditioners
Technical Data ISD 380, 465, 570, 670, 840, 950 Cooling Capacity 37.6kW - 94.9kW Heating Capacity 35.9kW - 90.1kW Contents ISD 380 950 General 3 Applications 4 Air Flow Selection 4 Features Refrigerant
More informationUMXCA/UMXCBA ECVA/ECVBA
OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationAHN 064 to 304 EHN/CHN 064 to 304
u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationR4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors
More informationVMDA Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the
More information14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]
More informationELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M
AIR CONDITIONERS ELS ELITE COMMERCIAL SPLIT SYSTEMS R-40A - 50 HZ Bulletin No. 49073 March 208 P R O D U C T S P E C I F I C AT I O N S Supersedes February 208 072-090 Models 80-240 Models 2 to 70 kw ing
More informationCGA CXA VGA VXA CG-PRC006-E4
Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationProduct Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS
DUCTED HEAT PUMP Sizes 018 To 060 1.5 To 5 Nominal Tons Product Data A08379 INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S Sound S Levels as low as 71 dba Design Features S New aesthetics S Small
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationDucted Split System Air Conditioners
Technical Data ISD 116, ISD 141, ISD 164, ISD 184, ISD 194, ISD 224 Cooling Capacity 11.4kW - 22.4kW Heating Capacity 10.8kW - 21.6kW Contents ISD 116 224 KYX SERIES 3 General 3 Applications 4 Air Flow
More informationDIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE
DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationV33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationVMDB Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs
More informationtechnical catalogue tetris KW Chiller and heat pumps air/water
technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit
More informationChiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw
Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic
More informationVHIA High-Static Ducted Indoor Units - 60HZ
PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage
More informationAQVSL/AQVSH STAR 85 to 140
Chiller QVSL/ STR 85 to 140 ir Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 82 to 157 kw 83 to 168 kw Outstanding Strength Points Units with R410 refrigerant (it will be the
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationLUI / LUO. Condensing Units
UI / UO Condensing Units Standard Construction Cabinet: The rugged cabinet is constructed of heavy gauge, mill galvanized steel. Easily removable top and personnel screen are provided for convenient component
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically
More informationRCD Air Cooled Condensing Unit (50/60 Hz)
Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60
More informationFORM NO. PTZ-806 REV. 1 HEAT PUMPS
FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More informationAir Cooled Packaged Units Technical Data
Technical Data OPA 2100 Eco Ultra Cooling Capacity 15kW - 200kW Heating Capacity 15kW -186kW Version 7 Contents OPA 2100 ECO ULTRA 3 General 3 Applications 4 Features 4 Energy Efficient Refrigerant R410A
More informationEnhanced Air Conditioning
4SCU16LT Split System Enhanced Air Conditioning COMPRESSOR High-efficiency 2 stage Copeland UltraTech TM scroll compressor R410a refrigerant Grommet-mounted compressor for quiet operation Internally protected
More informationPerformance. Sound Levels. Impellers. Motors. Accessories
EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class
More informationRPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.
RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit
More informationCommercial TRI-CAPACITY Performance and efficiencies through smart engineering. That s better. That s Actron.
Commercial Performance and efficiencies through smart engineering. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationS3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant
TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from
More informationWATER SOURCE HEAT PUMPS
HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units
More informationAIR COOLED CHILLERS WATER COOLED CHILLERS
AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationRCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.
RCE13 Product Specifications 13 SEER Electric / Electric Residential Packaged Unit Form No. RCE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced
More informationThe World Leading Air-conditioning Company
The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable
More information1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. WT-WFH-1115B W-Series Next-Gen Proline 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 W-Series The Next Generation of Prolines are Here! Witt s Next-Gen Proline W-Series ½
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 06.2016 Bosch Thermotechnology
More informationVWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three
More informationProduct Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:
PH13PA 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationTECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS
TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal
More information2SG13 60HZ P A C K A G E D G A S / E L E C T R I C
P A C K A G E D G A S / E L E C T R I C 2SG13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210453 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity 23,000 to
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More informationJT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump
TECHNICAL SPECIFICATIONS JT4BD Series 13 SEER 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump 3, 4, 5 Ton Capacities The JT4BD Series heat pump, when combined with our engineered
More information