Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
|
|
- Wendy Elliott
- 5 years ago
- Views:
Transcription
1
2 Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full range of HID wattage application: version for 70 W, 100 W, 150 W HID lamp & large body version for 150 W, 250 W, 400 W, 600 W HID lamp. The product offers users high efficient, safe, reliable and convenient application ex-proof lighting in harsh and hazardous areas. A large side mounted Ex e terminal chamber for Ex e IP66 water- and dustproof cable entries with easy wiring and looping option Application for high ambient temp C and low Different mounting modules for multiple mounting ambient temp C pattern: Wall mounting, ceiling mounting and pole Rugged copper free aluminum body and tempered mounting glass globe with best impact duration and corrosion External high efficiency reflector is available for special free feature task lighting as an option Full range of HID lamp wattage application: Rugged Ex de design for Zone 1 & Zone 21 application 70 W, 100 W, 150 W, 250 W, 400 W, 600 W IECEx & ATEX compliant Application Zone 1 & Zone 2: Oil refineries, shipboard & platforms, chemical, petrochemical & LNG plants, waste or sewage treatment, outdoor & indoor industrial locations; Zone 21 & Zone 22: Grain mills, sugar processing, wood processing, food processing, other combustible dust plants; Technical data Marking to 94/9/EC D II 2 G Ex d e IIC T... 1 ) Gb DII 2 D Ex td A21 IP66 T... 1 ) EC-Type Examination Certificate TÜV 12 ATEX 7169 X Marking acc. to IECEx IECEx CQM IECEx-Certificate of Conformity Ex d e IIC T 1 ) Gb Ex td A21 IP66 T 1 ) C Permissible ambient temperature Tamb: -40 C ~ +55 C Input voltage & frequency 220 V AC 50/60 Hz, 230V AC 50/60 Hz, 240 V AC 50 Hz Connecting terminals 3 x 2 x 4 mm 2 (L, N, PE) max. 2 conductor/cable Insulation class I Lamp HPS: 70 W, 100 W, 150 W, 250 W, 400 W, 600 W MH: 70 W, 100 W, 150 W, 250 W, 400 W Lamp holder E 27 (HPS 70 W & MH 70 W, 100 W, 150 W) E 40 (HPS 100 W W & MH 250 W W) Degree of protection accd. EN IP66 Cable entry 2 x M20 x 1.5 / 2 x M25 x entry is fixed with a Ex e plug Dimension : Ø 215 x 480 mm : Ø 300 x 599 mm Weight refer to different wattage 1 ) Material Body - Copper free aluminum Globe - Tempered glass External fasten screw - SS 316 Mounting bracket - steel with painted powder coating Finish - Painted polyester powder coating grey 1 ) See table temperature class
3 Ordering information Series No. Entry type Lamp type Entry size Wattage Voltage EVZ I = Indirect Entry S = HPS 1M = M20 07 = 70 W 3 = 220 V 50 Hz M = MH 2M = M25 10 = 100 W 4 = 220 V 60 Hz 15 = 150 W 5 = 230 V 50 Hz 6 = 240 V 50 Hz 7 = 230 V 60 Hz Series No. Entry type Lamp type Entry size Wattage Voltage Ignitor EVZ I = Indirect Entry S = HPS 1M = M20 15 = 150 W 3 = 220 V 50 Hz L = large body (only 150 W) M = MH 2M = M25 25 = 250 W 4 = 220 V 60 Hz 40 = 400 W 5 = 230 V 50 Hz 60 = 600 W (only HPS) 6 = 240 V 50 Hz 7 = 230 V 60 Hz Temperature class feature Without reflector With reflector Fixture Power Catalogue No. (W) Lamp Gas ( C) Dust ( C) Gas ( C) Dust ( C) 40 C 50 C 55 C 40 C 50 C 55 C 40 C 50 C 55 C 40 C 50 C 55 C EVZIS*07* HPS T5 T5 T T4 T4 T EVZIM*07* MH T5 T5 T T5 T4 T EVZIS*10* HPS T5 T4 T T4 T4 T EVZIM*10* MH T4 T4 T T4 T4 T EVZIS*15* HPS T4 T4 T T3 T3 T EVZIM*15* MH T4 T4 T T3 T3 T Weight (kg) Without reflector With reflector Fixture Power Lamp Gas ( C) Dust ( C) Gas ( C) Dust ( C) Weight Catalogue No. (W) (kg) 40 C 50 C 55 C 40 C 50 C 55 C 40 C 50 C 55 C 40 C 50 C 55 C EVZIS*15*L 150W HPS T4 T4 T T4 T4 T EVZIM*15*L MH T4 T4 T T4 T4 T EVZIS*25* 250W HPS T3 T3 T T3 T3 T EVZIM*25* MH T3 T3 T T3 T3 T EVZIS*40* 400W HPS T3 T3 T T3 T3 T EVZIM*40* MH T3 T3 T T3 T3 T EVZIS*60* 600W HPS T3 T3 T / / / / / / 20 3
4 Dimension and Mounting pattern Pole mounting Ceiling mounting Wall mounting Pole mounting Ceiling mounting Wall mounting Mounting module For both small & large body 4 U bracket for wall & ceiling mounting Permissible angle of 0 / 30 Pole mounting Permissible angle of 0 / 20
5 Accessories Item Product code "U" bracket for ceiling and wall mounting CCL CCL Bracket for pole mounting CCL RA reflector (RA725) - just for small body RD reflector (RD725) - just for small body RA reflector -just for large body CHR9973 (150W-400W only) RD reflector -just for large body CHR9972 (150W-400W only) SS316 wire guard for small body CHR8138 SS316 wire guard for large body CHR7870 Eye bolt CHR6196 Product family tree 5
6 Product family tree Note: RA/RD reflector for W only 6
7 Polar curve 70W HPS without guard & reflector 70W HPS with RA reflector 70W HPS with RD reflector 400W HPS without guard & reflector 400W HPS with RA reflector 400W HPS with RD reflector 7
EVZ Series (Small body) Explosion protected luminaire Operating Instructions
EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationI Ex-safety switches I
EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationI 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I
I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de
More informationI Ex-safety switches I
3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationMain current switches >180 A are realized in metal enclosures. Internationally approved.
E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationCROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights
CEAG Products Explosion protected floodlights CROUSE-HINDS SERIES PXLED - Power Floodlight Series for Hazardous Areas Explosion-protected LED floodlight series for Zone 1, 2, 21 and 22 Ex-Floodlight PXLED
More information9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More informationInternationally approved.
E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure
More informationUnused flameproof threads for cable glands have to be closed with certified plugs.
E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.
More informationEX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS
EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS 4 5 6 8 EX-CEILING LIGHT FITTINGS EX-PENDANT LIGHT FITTINGS 4.4 4.0 EX-FLOODLIGHTS EX-VESSEL LIGHT FITTING 4.8 4.46 0 ZONE / EX-PENDANT LIGHT FITTINGS
More informationATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen
Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationInternational approvals.
E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationLighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22
FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationWELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)
WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationEV 35 LED Robust Ex-pendant light fitting series with efficient lighting technology
LED technology for hazardous areas EV 35 LED Robust Ex-pendant light fitting series with efficient lighting technology LED Technology for Zone 1/2 and 21/22 The efficient solution for your illumination
More information4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)
4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are
More informationRLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22
Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018
More informationPower (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13
Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS ellb 20... 1-5 W Metallic design for Zone 1 and 21 The ellb 20 explosion-protected ceiling light fitting with electronic ballast meet the requirements of ATEX-Directive
More informationI Ex-control stations I
Type 11 83 Type 11 82 Type 11 81 Technical data Ex-control stations Type 11 81 I Type 11 82 I Type 11 83 Marking accd. to 9/9/EC II 2 G Ex ed ib m IIC T6 II 2 D Ex td A21 IP66 T80 C EC-Type Examination
More informationLighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof
Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type
More informationL: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L
Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:
More informationThe Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.
E X - T E R M I N A L E N C L O S U R E S Stainless Steel Version for Zone and Zone 2 The enclosure range is an ATEX certified enclosure / termination solution for category 2 (Zone) application with an
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationPROTECTA III. Construction Tough glass reinforced polyester body
PROTECTA III 20 Construction Tough glass reinforced polyester body Polycarbonate diffuser with high resistance to UV and stress cracking Robust hinges and multipoint compressive clamping of diffuser closure
More informationMercmaster LED Series Luminaires Enclosed and Gasketed Fixtures
Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical
More informationATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22
Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against
More informationATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationEWE. Ex de. Cooling fins
EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4
More informationAreamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent
Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1, Groups E, F, G Class II Division 2, Groups F, G Class III Simultaneous Exposure Type 3R, 4, 4X IP66/67 Applications
More informationJ: Emergency lighting (optional) L: pole type X: ceiling type Mounting
Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More informationK: bracket type. L: pole type
Lighting Technology Catalogue number logic B0091-0 -0 0 0 Pendant Light Fittings BDD91 Series Explosion-proof Light Fittings Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - M A N U A L M O T O R S T A R T E R S Up to A Motors have to be protected against over loads, phase failures and overheating: CEAG's power circuit breaker and manual motor starter features phase-failure
More informationCode Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.
Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationFluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety
Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationIIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof
IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire
More information7 Lighting Technology
7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources
More informationLeading the way in hazardous areas Features EATON
.2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected
More informationEX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS
1 EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 2 ouse se-hin inds 20 08 - all righ ghts re serv rved C ou Co oper Cr 3 4 5 6 7 EX-CEILING LIGHT FITTINGS 5.41 8 EX-PENDANT LIGHT FITTINGS EX-FLOODLIGHTS
More informationAreamaster LED Flood/High Bay Luminaires
Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust,
More informationN2MV Series W Non-metallic
N2MV Series 50-175W Non-metallic Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Marine & Wet Locations, R, 4, 4X; IP56 L Applications: N2MV series Champ
More informationellk/m 92 LED 400/800
Explosion-protected Linear LED Light Fitting for Zone 1 and 21 1.1 ellk/m 92 LED 400/800 Linear LED Ex-light fittings ellk/m 92 LED 400/800 / ellk 92 LED 400/800 CG-S/NIB (Zone 1, 2, 21, 22) The efficient
More informationI Ex-e/Ex-i terminal box I
ID TAG label & bracket Door document holder opti. Security padlock Hasp opti. Technical data Marking accd. to 94/9/EC II G Ex e II / II D Ex td A1 IP66 Temperature class T6 up to +40 C / T5 up to +55 C
More informationEWE. Cooling fins. Ex de
EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4
More informationFV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations
Applications For use in hazardous locations defined by the NEC and CEC as Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Marine Outdoor Salt Water; UL1598A and. As well
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationwww.greenelectricalsupply.com Page 1 of 4 The HLR SERIES hazardous location family of fixtures is suitable for use in a wide range of indoor and outdoor Class I Division 2 applications. Available in eight
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationYFC. Limit switch. Ex d. 24 operating head types
Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735
More informationellk 92 LED Light Fittings
CEAG Products Ex-Solutions LED Lighting ellk 92 LED Light Fittings Linear light fitting series with new LED module for hazardous areas Zone 1, 2, 21 and 22 www.crouse-hinds.de EATON 1.2.1 Ex-LED-Linear
More informationChamp MLL LED luminaires
The Champ MLL linear LED is specifically designed to replace fluorescent T12, T8 and T5HO lighting in harsh and hazardous applications. The rugged and durable design features the industry s most versatile
More informationATX PRE Series 125 Amp Plugs and Sockets Increased Safety
ATX PRE Series 125 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationFL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22
Standard and Emergency Back-Up. Applications Light duty luminaire ideal for commercial and light industrial locations including hazardous areas designated as Zone 2 or 22 environments. Typical applications
More informationSheet-Steel Light Fittings Series 6014 / 6414
> As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationATX PRE Series 63 Amp Plugs and Sockets Increased Safety
ATX PRE Series 63 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationCEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1
CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5
More informationApparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components
E X - D D I S T R I B U T I O N S with metal EJ enclosures for gases in explosion group IIB Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.
More informationHazardous Area LED Lighting Champ FMV LED Luminaires. Champ FMV. LED floodlights for harsh and hazardous areas
Hazardous Area LED Lighting Champ FMV LED Luminaires Champ FMV LED floodlights for harsh and hazardous areas Champ FMV LED floodlights Safe. Reliable. Efficient. Featuring the industry's broadest range
More informationHeavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor
Heavy industrial LED lighting Champ Pro PFM LED luminaires Champ PFM LED floodlights for heavy industrial areas Authorized Distributor Champ Pro PFM LED floodlights Safe. Reliable. Efficient. Featuring
More informationTubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22
Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance
More informationFloodlight Series 6521/4
> The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight
More information