7 Lighting Technology

Size: px
Start display at page:

Download "7 Lighting Technology"

Transcription

1 7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources highpressure sodium lamps (HSE) metal halide lamps (HIE) mercury lamps (HME) induction lamps (QL) blended lamps (LME) halogen lamps (QT) incandescent lamps (A) Versatile mounting methods ceiling, wall and pole mounting mounting bracket pendant mounting Housing made of salt water resistant aluminium Replacement glass made of temperature resistant borosilicate glass External reflector made of powder coated galvanized sheet steel 7/94Zones 2, 21 & 22General Catalogue

2 Pendant Light Fitting IEC Size 1 up to 150 W 7 Selection table Version Lamps 1) Lampholder Pendant Light Fitting IEC Size 1 up to 150 W Power Temperature class T O max. 55 C Ordering code 40 C 55 C kg Weight A 200 W T4 T4 130 C 6470/ ,217 QT 150 W T5 T4 121 C 6470/ , W T4 T3 149 C 6470/ ,300 LME 160 W T4 T3 143 C 6470/ ,217 HIE 70 W T4 T4 103 C 6470/ , W T4 T4 121 C 6470/ , W T4 T3 140 C 6470/ ,115 HSE 50 W T4 T4 98 C 6470/ , W T4 T4 106 C 6470/ , W T4 T4 124 C 6470/ ,463 HME 125 W T5 T3 142 C 6470/ ,463 QL Special 55 W T6 75 C * 6470/ ,857 * at a maximum ambient temperature of 40 C Add. to ordering code Mounting Pendant mount via ring bolts 6470/ ,164 Mounting via mounting bracket 6470/ ,065 Ceiling mount 6470/ ,064 Wall mount 6470/ ,937 Stanchion mount / ,144 Stanchion mount / ,489 Pendant mount 6470/ ,778 Cable entries 4 x M 25 x 1.5 (standard) 1 x cable gland, 3 x stopping plug 6470/ ,035 4 x M 20 x x cable gland, 3 x stopping plug 4 x M 25 x 1.5 for through wiring 2 x cable gland, 2 x stopping plug 4 x M 20 x 1.5 for through wiring 2 x cable gland, 2 x stopping plug 6470/ , / , / , / 2 BSP for stanchion mount 6470/ / 4 BSP for stanchion mount 6470/ / 4 NPT for Pendant mount 6470/ NPT for pendant mount 6470/ Compensation without compensation 6470/ with compensation 6470/ ,064 Wire guard without wire guard 6470/ with wire guard 6470/ ,240 Surface with colour (standard) 6470/ Notes: 1) A QT LME HIE HSE HME QL Incandescent lamps Halogen lamps Blended lamps Metal halide lamps Highpressure sodium lamps Mercury lamps Induction lamps (supplied with light fitting) The light fittings are supplied without lamps (see accessories); Exception: lamps QL External reflector (see accessories) 7/95

3 7 Pendant Light Fitting IEC Size 2 up to 250 W Selection table Version Lamps 1) Lamphol der Pendant Light Fitting IEC Size 2 up to 250 W Power Temperature class T O max. 55 C Ordering code 40 C 55 C kg Weight LME 250 W T3 T3 170 C 6470/ ,091 HIE 250 W T3 145 C * 6470/ ,596 HSE 100 W T5 T4 112 C 6470/ , W T4 T4 130 C 6470/ , W T3 T3 157 C 6470/ ,596 HME 250 W T3 172 C * 6470/ ,139 QL Special 85 W T5 86 C * 6470/ ,535 * at a maximum ambient temperature of 40 C Add. to ordering code Mounting Pendant mount via ring bolts 6470/ ,164 Cable entries Mounting via mounting bracket 6470/ ,065 Ceiling mount 6470/ ,064 Wall mount 6470/ ,937 Stanchion mount / ,144 Stanchion mount / ,489 Pendant mount 6470/ ,778 4 x M 25 x 1.5 (standard) 1 x cable gland, 3 x stopping plug 4 x M 20 x x cable gland, 3 x stopping plug 4 x M 25 x 1.5 for through wiring 2 x cable gland, 2 x stopping plug 4 x M 20 x 1.5 for through wiring 2 x cable gland, 2 x stopping plug 6470/ , / , / , / , / 2 BSP for stanchion mount 6470/ / 4 BSP for stanchion mount 6470/ / 4 NPT for Pendant mount 6470/ NPT for pendant mount 6470/ Compensation without compensation 6470/ with compensation 6470/ ,064 Wire guard without wire guard 6470/ with wire guard 6470/ ,280 Surface with colour (standard) 6470/ Notes: 1) LME HIE HSE HME QL Blended lamps Metal halide lamps Highpressure sodium lamps Mercury lamps Induction lamps (supplied with light fitting) The light fittings are supplied without lamps (see accessories); Exception: lamps QL External reflector (see accessories) 7/96

4 Pendant Light Fitting IEC Size 3 up to 600 W 7 Selection table Version Lamps 1) Lampholder Pendant Light Fitting IEC Size 3 up to 600 W A QT LME Power 500 W T4 T4 T3 Temperature class T O max. 55 C Ordering code 40 C 55 C kg T3 T3 T3 137 C 142 C 165 C Weight 6470/ ,868 HIE 250 W T4 T4 130 C 6470/ , W T3 T3 155 C 6470/ ,545 HSE 250 W T4 T4 132 C 6470/ , W T4 T3 146 C 6470/ , W T3 166 C * 6470/ ,103 HME 250 W T4 T3 145 C 6470/ , W T3 153 C * 6470/ ,708 QL Special 165 W T6 80 C * 6470/ ,189 * at a maximum ambient temperature of 40 C Add. to ordering code Mounting Pendant mount via ring bolts 6470/ ,800 Cable entries Mounting via mounting bracket 6470/ ,900 Ceiling mount 6470/ ,600 Wall mount 6470/ ,400 Stanchion mount / ,100 Stanchion mount / ,800 Pendant mount 6470/ ,200 4 x M 25 x 1.5 (standard) 1 x cable gland, 3 x stopping plug 4 x M 20 x x cable gland, 3 x stopping plug 4 x M 25 x 1.5 for through wiring 2 x cable gland, 2 x stopping plug 4 x M 20 x 1.5 for through wiring 2 x cable gland, 2 x stopping plug 6470/ , / , / , / , / 2 BSP for stanchion mount 6470/ / 4 BSP for stanchion mount 6470/ / 4 NPT for pendant mount 6470/ NPT for pendant mount 6470/ Compensation without compensation 6470/ with compensation 6470/ ,650 Wire guard without wire guard 6470/ with wire guard 6470/ ,650 Surface with colour (standard) 6470/ Notes: 1) LME HIE HSE HME QL Blended lamps Metal halide lamps Highpressure sodium lamps Mercury lamps Induction lamps (supplied with light fitting) The light fittings are supplied without lamps (see accessories); Exception: lamps QL External reflector (see accessories) 7/97

5 7 Pendant Light Fitting IEC Technical Data Explosion protection Gas explosion protection E II 3 G EEx nr II T* Dust explosion protection E II 2 D IP 66 T O. max* E II 3 D IP 66 T O. max* * temperature classes and surface temperatures see selection table Certificates PTB 05 ATEX 2045 (Zones 2, 22) PTB 05 ATEX 2043 (Zone 21) Other certificates IECEx Marking C 0102 Rated operational voltage U e Rated current Power factor Protection class Connection Material Enclosure material Replacement glass Cover seal Glass seal Mounting bracket External reflector Wire guard Housing lock Mounting 230 V, AC ± 10%, 50 Hz, others on request mind information on the typelabel Lamps Power Lampholder I N cos p ) 0.9 (compensated) I (PEconnection) L1 + N for 4 mm 2 solid and 6 mm 2 flexible via internal terminal block salt water resistant aluminium temperature resistant borosilicate glass silicone rubber silicone rubber stainless steel powder coated galvanized sheet steel / glass fibre reinforced polyester salt water resistant aluminium Degree of protection IP 66 Ambient temperature 20 C C 30 C C 50 C C Incandescent lamps A 200 W 500 W Halogen lamps QT 150 W 250 W 500 W Blended lamps LME 160 W 250 W 500 W Metal halide lamps HIE 70 W 100 W 150 W 250 W 400 W Highpressure sodium lamps HSE 50 W 70 W 100 W 110 W 150 W 250 W 400 W 600 W Mercury lamps HME 125 W 250 W 400 W Induction lamps QL 55 W 85 W 165 W Mounting screw M 8 (stainless steel) special special special 0,87 A 2,27 A 0,65 A 1,10 A 2,10 A 0,65 A 1,17 A 2,17 A 0,95 A 0,78 A 0,88 A 1,55 A 2,10 A 0,77 A 0,44 A 0,70 A 0,72 A 1,80 A 1,40 A 2,10 A 3,10 A 0,70 A 2,22 A 1,96 A 0,26 A 0,40 A 0,70 A wall and ceiling mount, stanchion mount, pendant via ring bolts, mounting via bracket or pendant all versions for highpressure sodium lamps, metal halide lamps for mercury lamps, halogen lamps, incandescent lamps and blended lamps Wire guard and external reflector can easily be mounted later using M 6 screws 7/98

6 Pendant Light Fitting IEC 7 Technical Data Cable glands Certified cable glands with an ingress protection of IP66 minimum must be used (in acc. with 94/9/EC). The number of cable entries depends on the type of mounting. Standard Special M 25 x 1,5 M 20 x 1,5, others on request Screwin thread for stanchion mounting 1 1 / 4 BSP, 1 1 / 2 BSP, 3 / 4 NPT, 1 NPT Accessories and spare parts Designation Illustration Description Ordering code Weight kg Power Lampholder Voltage Lighting current Incandescent lamps A 04958E W 230 V 3100 Im 500 W 230 V Im , ,140 Halogen lamps QT 05355E W 230 V 2500 lm 250 W 230 V 4200 Im , , W 230 V Im ,132 Blended lamps LME 04963E W 230 V 3150 lm 250 W 230 V 5500 lm , , W 230 V lm ,280 Metalhalide lamps HIE 04963E00 70 W 230 V 6500 Im 100 W 230 V 8000 Im , , W 230 V Im , W 230 V Im , W 230 V Im ,284 Highpressure sodium vapour lamps HSE 04963E00 50 W 230 V 3500 lm 70 W 230 V 6000 Im , , W * 230 V 8000 Im ,150 * to operate without starter 100 W 230 V 9500 Im , W 230 V Im , W 230 V Im , W 230 V Im , W 230 V lm , E00 Highpressure sodium vapour lamps HSE (TwinArc) 04963E00 50 W 230 V 3600 Im 70 W 230 V 6000 Im , , W 230 V 9500 lm , W 230 V lm , W 230 V lm , W 230 V lm ,214 7/99

7 7 Pendant Light Fitting IEC Accessories and spare parts Designation Illustration Description Ordering code Weight kg Mercury lamps HME 125 W 230 V 6500 lm , W 230 V Im , E00 Induction lamps QL 400 W 230 V Im 55 W special 230 V 3500 lm 85 W special 230 V 6000 lm , , , E W special 230 V lm ,300 Replacement glass temperature resistant borosilicate glass with screwin thread for 6470/ , E00 for 6470/ , ,500 Wire guard made of salt water resistant aluminium, with mounting parts for 6470/ , E00 for 6470/ , ,750 Standard reflector made of powder coated galvanized sheet steel, with mounting parts 6470/ , E00 made of glass fibre reinforced polyester, with mounting parts for 6470/ ,500 Mounting bracket made of stainless steel, with mounting parts 6470/ ,200 for 6470/ , E00 Cover for ceiling mounting 10580E00 Ceiling mount via taps found on the cover. A mounting bracket or ring bolts can be attached to the cover later (must be ordered as accessory). with thread M 20 x ,264 with thread M 20 x 1.5 for 6470/ ,000 with thread M 25 x ,264 with thread M 25 x 1.5 for 6470/ ,000 Cover for wall mounting with thread M 20 x , E00 with thread M 20 x 1.5 for 6470/ ,600 with thread M 25 x ,137 with thread M 25 x 1.5 for 6470/ ,600 7/100

8 Pendant Light Fitting IEC 7 Accessories and spare parts Designation Illustration Description Ordering code Weight kg Cover for pole mounting 25 with thread 1 1 / 2 BSP , E00 with thread 1 1 / 2 BSP for 6470/ ,300 with thread 1 1 / 4 BSP ,344 with thread 1 1 / 4 BSP for 6470/ ,300 Cover for pole mounting 90 with thread 1 1 / 2 BSP , E00 with thread 1 1 / 2 BSP for 6470/13 with thread 1 1 / 4 BSP with thread 1 1 / 4 BSP for 6470/ , , ,000 Cover for pendant mount with thread 3 / 4 NPT , E00 with thread 3 / 4 NPT for 6470/ ,400 with thread 1 NPT ,978 with thread 1 NPT for 6470/ ,400 Ring bolts M 8, to mount directly into inserts, 1 pair ,107 M 10, to mount directly into inserts, 1 pair ,103 Cable entries 05378E00 in moulded plastic 8161/5M piece , E /5M pieces , /5M piece , /5M pieces ,850 Stopping plugs in moulded plastic 8290/3M 20 x piece , E /3M 20 x pieces , /3M 25 x piece , /3M 25 x pieces ,800 Special key for tightening the cable glands respectively the cap nuts 05263E00 for cable entries Thread size Type Packing unit Handheld testing instrument for gastight enclosures M 20 x /.M For testing of restricted breathing of gastight enclosures of type EEx nr , , E00 7/101

9 7 Pendant Light Fitting IEC Dimension drawings (all dimensions in mm) subject to alterations Dimensions in mm 6470/ / /13 A B C D E F G H M 8 M 8 M 10 I J Ceiling mount without wire guard 10574E E E00 Ceiling mount with wire guard Ceiling mount with reflector Dimensions in mm 6470/ / /13 A B B C G H M 8 M 8 M 10 K L M N P Pendant mount via ring bolts 10568E E E00 Pendant mount via mounting bracket Pendant mount 7/102

10 Pendant Light Fitting IEC 7 Dimension drawings (all dimensions in mm) subject to alterations Dimensions in mm 6470/ / /13 A B C J Q R S T V X Y E E E00 Wall mount Stanchion mount 25 Stanchion mount 90 We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustrations cannot be considered binding. 7/103

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

Floodlight Series 6521/4

Floodlight Series 6521/4 > The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight

More information

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5

More information

Pendant Light Fitting IEC

Pendant Light Fitting IEC Pendant Light Fitting IEC Operating instructions Additional languages www.r-stahl.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

K: bracket type. L: pole type

K: bracket type. L: pole type Lighting Technology Catalogue number logic B0091-0 -0 0 0 Pendant Light Fittings BDD91 Series Explosion-proof Light Fittings Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2

More information

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22) .5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust

More information

Sheet-Steel Light Fittings Series 6014 / 6414

Sheet-Steel Light Fittings Series 6014 / 6414 > As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

Compact Sheet-Steel Light Fittings Series 6114

Compact Sheet-Steel Light Fittings Series 6114 > As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in

More information

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408 > As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting

More information

EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS

EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS 4 5 6 8 EX-CEILING LIGHT FITTINGS EX-PENDANT LIGHT FITTINGS 4.4 4.0 EX-FLOODLIGHTS EX-VESSEL LIGHT FITTING 4.8 4.46 0 ZONE / EX-PENDANT LIGHT FITTINGS

More information

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 > For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 1 EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 2 ouse se-hin inds 20 08 - all righ ghts re serv rved C ou Co oper Cr 3 4 5 6 7 EX-CEILING LIGHT FITTINGS 5.41 8 EX-PENDANT LIGHT FITTINGS EX-FLOODLIGHTS

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Sheet-Steel Emergency Light Fitting 09361E00 and 6418 (Zones 2, 21 and 22) emergency light fittings in sheet-steel can be used for safety illumination, especially in spraying and

More information

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

Sheet Steel Emergency Light Fitting Series 6018

Sheet Steel Emergency Light Fitting Series 6018 > For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and

More information

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de

More information

Safety Switches Series 8537

Safety Switches Series 8537 Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part

More information

EWE. Ex de. Cooling fins

EWE. Ex de. Cooling fins EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4

More information

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURES FOR INANDESENT AND DISHARGE LAMPS Explosion Proof Electrical Equipment Ex Lighting Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) lassification: Group II -

More information

Linear fluorescent luminaire LED V-CG-S

Linear fluorescent luminaire LED V-CG-S (2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008 Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency

More information

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018

More information

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

Tank Inspection Lights Series 6122

Tank Inspection Lights Series 6122 > For halogen lamps 5 W to 100 W > Mounting options tilting hinge mounting bracket flange collar > Corrosion-resistant light metal enclosure > Connection options potted connection lead connection www.stahl.de

More information

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated

More information

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact

More information

11 Control Panels, Distribution Panels and Components

11 Control Panels, Distribution Panels and Components Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific) 4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are

More information

Junction box for EKL light

Junction box for EKL light M EKL light Junction box Junction box for EKL light Features Chemical-resistant Temperature-resistant Flame-retardant Absolutely corrosion-proof Seawater-proof Description Polyester enclosures have proven

More information

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,

More information

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22 SLEE - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22 S u p p or t i n g br a c ket Hin ge for op en in g

More information

International approvals.

International approvals. E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for

More information

9 Control Equipment. Control Unit System Series ConSig 8040

9 Control Equipment. Control Unit System Series ConSig 8040 9 Control Equipment Control Unit System Explosion protection to CENELEC IEC NEC Can be used in Zone 1 and Zone 2 Standard and customized units 3 sizes available Enclosures in glass fibre reinforced polyester

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

About us. 2 make your work surroundings safer

About us. 2 make your work surroundings safer About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear

More information

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/ d.o.o. tel. 049 222 900 fax. 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/ No: TEPEx.RS.028 Rev : 1 Date: 09.2014. SADRŽAJ 1. Manufacturer 1 2. General

More information

EWE. Cooling fins. Ex de

EWE. Cooling fins. Ex de EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4

More information

1000W and 2000W versions

1000W and 2000W versions 503 FLOODLIGHT 126 600W HPS 1000W and 2000W versions The 503 is a high powered floodlight with a wide ambient temperature range. The high upper ambient and corrosion resistant aluminium constriction, make

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C... EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)

More information

Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures 42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

I Ex-Safety switches I

I Ex-Safety switches I 3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX

More information

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22) .15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full

More information

HIGH BAY - PROFESSIONAL COPA

HIGH BAY - PROFESSIONAL COPA HIGH BAY - PROFESSIONAL COPA 142 COPA COPA I IP20 IP65 I-RAB 1/250-400, T 1/250 I-RAT 1/400 I-RAN 1/250-400 I-RKID PRISM 1/250-400 I-RAB 1/250-400, T 1/250 I-RAT 1/400 HME HME HME HME HI-AG 500 HI-AG 500

More information

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

I Ex-safety switches I

I Ex-safety switches I 3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99

More information

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W /27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3

More information

Unused flameproof threads for cable glands have to be closed with certified plugs.

Unused flameproof threads for cable glands have to be closed with certified plugs. E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.

More information

Easy and safe installation

Easy and safe installation ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22 Standard and Emergency Back-Up. Applications Light duty luminaire ideal for commercial and light industrial locations including hazardous areas designated as Zone 2 or 22 environments. Typical applications

More information

Control Panels, Distribution Panels and Components

Control Panels, Distribution Panels and Components 11 Control Panels, Distribution Panels and Components EEx d Enclosures in Light Metal or stainless steel Flexible modular design for combining enclosures Can be used in Zone 1 and Zone 2 in Zone 21 and

More information

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A Co nt act or Heating Guides, 9-95A switching in the event of prolonged overloads at 1.05 Un. 220 / 240V 380 / 415V 660 / 690V 4 7 12 D1210** 2 Pole 5 9 15.5 D1810** 6 11 19 D2510** 8.5 15 25.5 D3210**

More information

Portable Lamps Series HS6145, HSL145

Portable Lamps Series HS6145, HSL145 www.stahl.de > Portable Lamps Series HS6145 > Comply with requirements of Fire Department standard DIN 14462 > Battery state display > Open circuit monitor > Light intensity 15.000 cd after 4 hours use

More information

Increased Safety Mercury Lamp Lighting Fittings

Increased Safety Mercury Lamp Lighting Fittings Increased Safety Mercury Lamp Lighting Fittings High reliability in protection against explosion The HGLB lighting fittings are designed and constructed thoroughly with carefully selected materials to

More information

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22 FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4

More information