1 EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS EX-CEILING LIGHT FITTINGS EX-PENDANT LIGHT FITTINGS EX-FLOODLIGHTS EX-VESSEL LIGHT FITTING ZONE / EX-PENDANT LIGHT FITTINGS ZONE / EX-FLOODLIGHTS ACCESSORIES 4.

2 I Ex-ceiling, pendant light fittings and floodlights I Field of application of pendant light fittings and floodlights with high pressure discharge lamps in hazardous areas. Where a lot of light is needed and/or where large complexes or areas have to be illuminated, or where there are high ceilings, these are the ideal situations for pendant light fittings and floodlights. The main field of operation is the illumination in hazardous explosive environments such as On- and Offshore areas, production and storage buildings or Ex-companies in the chemical industry. Also the illumination of outside areas such as loading zones, harbour areas or even refineries. The pendant light fittings and floodlights are usually fitted with high pressure discharge lamps such as Metal halide lamp or Sodium vapour lamps. They offer a high output of light and a relatively long life span. Due to environmental protection the use of Mercury Vapor lamps have been forbidden in more and more countries. The typ of lamp may be replaced by other light sources e.g. Metal halide or sodium vapour lamps. 4. COOPER CROUSE-HINDS GMBH

3 I Ex-ceiling, pendant light fittings and floodlights I With the CEAG pendant light fittings and floodlights for the Zones,, and you have a safety assurance even in difficult environmental con - ditions such as high and low temperature, high humidity, dusty and aggres - sive explosive atmospheres. The high safety standard required is assured for even after a long period of usage time. A long service life and the high reliability factor of the used electrical and mechanical components makes these lamps extremely cost-effective. Especially the innovative illuminant technology of the induction lamps used in the EVQ light fittings guarantees a lamp life expectancy of >,000 hours. This makes these light fittings destinied for usage in uncomfortable and hard to access areas where one can efficiently minimize the maintanance costs. Pendant light fitting EVQ for Induction lamps The easy changing of the lamp, for example in the new CEAG floodlight series FZD (you just change the complete lamp module), also effectively reduces the maintanance costs. Even in extreme environments and temperatures of -40 C you can be sure that the light fittings will be quickly back in use. The actual lamp replacement can then take place in the work-shop at a later date Bulk head light fitting AB FZD flood light COOPER CROUSE-HINDS GMBH 4.

4 E X - C E I L I N G L I G H T F I T T I N G S AB 05, AB 80 and AB NAV 0 Metal Version for Zone and AB 05 This explosion-protected light fitting for Incan - descent as well for high pressure discharge lamps is designed in accordance to the ATEX- Directive 4//EG. The light fittings are fitted with an impact resis - tant and thermally stable dome-shaped glass. All external screws are made of high quality stainless steel. The distinguishing characteristics of this series are the low weight and the simple installation. The control gear for HPS-lamps is installed on a removeable support in order to make the maintenance easy. The AB 05 series offers a wide range of application using different type of explosion protection: Ex e IIC for Zone / Ex de IIB (+H as an option) for Zone / Ex nr for Zone / An internal aluminium reflector enables a well balanced light distribution characteristic. AB 80 Due to the flameproof design all types of incandescent lamps up to 00 W or suitable compact fluorescent lamps with electronic ballast can be used. The AB 80 light fitting is a flat light fitting for ceiling mounting. Due to their robust architecture, this light fitting is suitable for use in the chemical industry and have been certified for usage in environments with a temperature of up to +55 C. AB NAV 0 This compact Ex-d light fixture for high pressure sodium lamps allows individual lighting solutions for areas with limited mounting space. Lamp, ballast capacitor and ignitor are incorporated on a compact module, which allows easy re-lamping and maintenance procedure. An optional external reflector allows individual illumination of working places. Certified for environmental temperatures from -55 C up to +55 C, depend. on type Fulfils highest requirements on corrosion protection and mechanical stability Robust light alloy housing (AB 05, AB NAV 0) Easy installation High quality stainless steel screws, easier lamp replacement 4.4

5 I Ex-ceiling light fittings I Technical data AB 05 Ex nr AB 05 Ex de Ex-Bulkhead light fitting AB 05 Marking to 4//EC AB 05 Ex-e II G Ex de IIC T/T II D Ex td A IP66 T5 C AB 05 Ex-d II G Ex d IIB (+H) T4/T ) AB 05 nr II G nr II T4/T II D Ex td A IP66 T00/5/40 C EC-Type Examination Certificate AB 05 Ex-e BVS 0 ATEX E 5 X AB 05 Ex-d PTB 08 ATEX 00 X Type Examination Certificate AB 05 nr BVS 0 ATEX E 5 Permissable ambient temperature 0 C to +40 C 55 C to +55 C (option, depends on version) Rated voltage max. 50 V ) (AB 05 Ex e/nr) 0 V (AB 05 Ex d) Frequency 50 - Hz Connecting terminals L, N, x.5-4 mm, PE: x.5-4 mm Insulation class I Lamp/Illuminant ) Degree of protection accd. EN 5 IP66 Cable glands/gland plates/enclosure drilling x M0/M5 x.5 / x M0/5 x.5 one plugged, or x /4 ISO // x /4 ISO / one plugged Dimensions (L x W x H) x 0 x 5 mm Weight ) Type of mounting ceiling/wall mounting Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass Enclosure earth x 6 mm ) see ordering details ) other voltages on request Dimension drawing Polar curves >40 >40 AB 05 Polar curve AB 05 Ex de Polar curve AB 05 nr C 0 C l/cd/klm 5 C 0 C l/cd/klm Dimensions in mm COOPER CROUSE-HINDS GMBH 4.5

6 I Ex-ceiling light fittings I AB 05 Ex de AB 05 Ex nr Ordering details Type Type of lamp Rated Temperature Cable glands/threads Weight/ Qty. Order No. luminous class kg flux ) II G IIC ( 0 C up to +55 C) AB 05 Ex de incandescent max. W 0 lm T/T ) x M0 5. AB AB 05 Ex de incandescent max. W 0 lm T/T ) x M0, x Ex-e M0 5. AB AB 05 Ex de incandescent max. W 0 lm T/T ) x M5 5. AB AB 05 Ex de incandescent max. W 0 lm T/T ) x M5, x Ex-e M5 5. AB II G Ex nr II (- 50 ºC up to + 55 ºC) AB 05 nr 0 W HSE 50 lm T4 x M0 5.4 AB AB 05 nr 0 W HSE 50 lm T4 x M0, x Ex-e M0 5.4 AB AB 05 nr 0 W HSE 50 lm T4 x M5 5.4 AB AB 05 nr 0 W HSE 50 lm T4 x M5, x Ex-e M5 5.4 AB AB 05 nr 0 W HSE ) 50 lm T4 x M5 5.4 AB AB 05 nr 0 W HSE ) 50 lm T4 x M5, x Ex-e M5 5.4 AB AB 05 nr 80 W HME 800 lm T4 x M5 5.4 AB AB 05 nr 80 W HME 800 lm T4 x M5, x Ex-e plug 5.4 AB AB 05 nr 00 W HME 00 lm T x M5 5.4 AB AB 05 nr 00 W HME 00 lm T x M5 5.4 AB II G IIB +H (- 0 ºC up to + 55 ºC) AB 05 Ex d 0 W HSE 50 lm T4 x M0 thread 6. AB AB 05 Ex d 0 W HSE ) 50 lm T4 x M0 thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x Ex d NPT / thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x Ex d NPT / thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x Ex d NPT /4 thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x Ex d NPT /4 thread 6. AB AB 05 Ex d 0 W HSE ) 50 lm T4 x Ex d NPT /4 thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x M0 thread 6. AB x M0 plug AB 05 Ex d 0 W HSE ) 50 lm T4 x M0 thread 6. AB II G IIB (- 0 ºC up to + 55 ºC) AB 05 Ex d 0 W HSE 50 lm T4 x M0 thread 6. AB AB 05 Ex d 0 W HSE ) 50 lm T4 x M0 thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x Ex d NPT / thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x Ex d NPT / thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x Ex d NPT /4 thread 6. AB AB 05 Ex d 0 W HSE ) 50 lm T4 x Ex d NPT /4 thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x M0 thread 6. AB x M0 plug AB 05 Ex d 0 W HSE ) 50 lm T4 x M0 thread 6. AB AB 05 Ex d 0 W HSE 50 lm T4 x Ex d NPT /4 thread 6. AB ) T only with lamp accd. to EN 064 and DIN 480 marked T ) depends on used lamps ) for HSE lamps with integrated ignitor Lamps and fixing accessories are not included. Metal cable glands see page COOPER CROUSE-HINDS GMBH

7 I Ex-ceiling light fittings I Technical data AB 80 Ex-Bulkhead light fitting AB 80 Marking to 4//EC II G Ex d IIB T4 (up to 00 W) / T6 ( W PL) ) EC-Type Examination Certificate LOM 0 ATEX 04 X Permissable ambient temperature 0 C C Rated voltage max. 50 V Connecting terminals x.5 mm or x.5 mm ; PE x 6 mm Insulation class I Incandescent lamp W, 00 W Lamp/Illuminant TC-DSE W Lamp cap E Rated luminous flux ) 0 lm / lm / 6 lm Light efficiency in operation % Degree of protection accd. EN 5 IP55 Cable glands/gland plates/enclosure drilling x /4 ISO /-/ x M5 x.5 thread (Ex-d), one plugged Weight 6. kg Type of mounting wall/ceiling mounting Enclosure material cast iron Enclosure colour grey Protective cover/protective bowl mechanical and chemical high resistent glass Enclosure earth x 6 mm ) depends on lamp Ordering details Type Entry thread Cable gland Ex-d for cable Ø Blanking plug Ex-d Order No. AB 80 with cable gland x /4-4 mm x /4 NOR AB 80 x /4 x /4 NOR AB 80 x M5 x M5 NOR Lamps and fixing accessories are not included Accessories Type Content Application Order No. GAB 80 wire guard AB 80 NOR REP.AB 80 spare glass AB 80 NOR Metal cable glands see page Dimension drawing entry optional entry, on request AB 80 Dimensions in mm COOPER CROUSE-HINDS GMBH 4.

8 I Ex-Bulkhead light fitting I AB NAV 0 Technical data Ex-Bulkhead light fitting AB NAV 0 Marking to 4//EC II G Ex d IIC / IIB T / II D Ex td A IP6 T C EC-Type Examination Certificate LOM 0 ATEX 0 X IECEx Certificate of Conformity IECEx BKI X Marking accd. to IECEx Ex d IIC / IIB T Permissible amient temperature 0 C to +55 C Gas group IIC 45 C to +55 C Gas group IIB Rated voltage 0 V ) Rated current 0,6 A Frequency 50 Hz Power factor cos ϕ 0, Connecting terminals L, N, PE: x.5 mm, PE x 6 mm Insulation class I Lamp/Illuminant HSE 0 W Lamp cap E Rated luminous flux ) 50 lm Light efficiency in operation 0 % Degree of protection accd. EN 5 IP6 Cable glands/gland plates/enclosure drilling x /4 ISO / thread (Ex-d) one plugged Weight 5.0 kg Type of mounting Wall/ceiling mounting Enlcosure material light alloy Enclosure colour grey Protective cover Borosilicate glass tube ) depends on lamp 4.8 COOPER CROUSE-HINDS GMBH

9 I Ex-Bulkhead light fitting I Ordering details AB NAV 0 Type Entry thread Cable gland Blanking plug Qty. Order No. Ex-d for cable Ø Ex-d Group IIC - NORMAL (ambient temperature) ( 0 C to +55 C) AB NAV 0 + PE x /4-4 x /4 NOR AB NAV 0 x /4 x /4 NOR Group IIB - LOW (ambient temperature) (up to 45 C) AB NAV 0 x /4 x /4 NOR Lamps and fixing accessories are not included Accessories 5 AB NAV 0 Type Content Order No. D Ceiling bracket with screws and polyamide washer (CrNi, pcs.) A5 Ceiling bracket hot galvanized ( pc.) NOR BFP45 Wall bracket 45 hot galvanized ( pc.) NOR RAB 08 Reflector AISI 04 NOR RAB 08 Reflector AISI 04 + guard (steel white epoxy coating) NOR RAB 08 Reflector AISI 6 NOR RAB 08 Reflector AISI 6 + guard (steel white epoxy coating) NOR Metal cable glands see page Dimensions drawing Polar curve M8xmm 8 6 optional entry, on request entry 4 AB NAV 0 Polar curve AB NAV C 0 C l/cd/klm Dimensions in mm COOPER CROUSE-HINDS GMBH 4.

10 E X - P E N D A N T L I G H T F I T T I N G S for incandescent and high pressure discharge lamps up to 500 W Metal version for Zone / All explosion-protected pendant light fittings for Incandescent, high pressure discharge and Induction lamps are in accordance with the ATEX-Directive 4//EG. AB 50/SPG N and AB5 Due to their compact design the series AB 50, SPG N and AB 5 are designed for individual illumination of a local area. Beside the copperfree aluminium housings all external screws are made of stainless steel. The protective glass dome is made of borosilicate glass which has a high mechanical and thermic stability. This ensures a save use even in harsh environmental areas. Most of the world-wide field conditions can be accepted by the large permissible ambient temperature range from 50 C up to +55 C. EVI and EV The housing is made of a copper-free aluminium. The ballast for the high pressure discharge lamps (EVM/EVS/EVH) is thermically separated in its own compartment in the top part of the housing. The dome-shaped glass enclosure is made of borosilicate glass which has a high mechanical and thermic stability. All external screws and the reflector are made of stainless steel. The lamp replacement is done by opening the PTFE coated connection ring. Both the glass enclosure and the connection ring are hinged for easy access. Due to their robust architecture, these light fittings are suitable for use in the chemical industry and have been certified for usage in environments with a temperature of up to +55 C (EVQ excluded). The new light fitting EVQ, designed for lamp replacement in > 000 hour intervals are fitted with induction lamps and a high-frequency generator. For environmental temperatures range of 50 C up to +55 C (EVQ excluded) Safety Standard IP6 Robust light alloy housing Easy opening of lamp compartment 4.0

11 I Ex-Pendant light fittings I Technical data SPG N AB 50 IXM AB 50 IU AB 50 SPG N Marking to 4//EC II G Ex d IIC T (direct entry IU); T4 with W at tamp +40 C ) (new standard applied for) II G Ex de IIC T (indirect entry IXM) II D Ex td IP6 T80 C, T0 with W at +40 C EC-Type Examination Certificate LOM 0 ATEX 08 X Permissible ambient temperature -0 C to +55 C -50 C to +55 C (option: AB 50) Rated voltage max. 50 V Power consumption max. 00 W Connecting terminals x.5 mm / x.5 mm (IU and SPGN), x.5 mm, PE x 6 mm (IXM) Insulation class I Incandescent lamp W, 00 W, 5 W halogene ) Lamp cap E Rated luminous flux ) 0 lm / lm Light efficiency in operation 68 % Degree of protection accd. EN 5 IP6 Cable glands/gland plates/enclosure drilling x /4 ISO /-thread (Ex-d), one plugged (UI) / x M5 x,5 (IXM), SPGN incl. cable gland Dimensions (L x W x H) see dimension drawing Weight see table Type of mounting ceiling mounting Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass ) depends on lamp ) 5 W halogene lamp max ta = +40 C COOPER CROUSE-HINDS GMBH 4.

12 I Ex-Pendant light fittings I AB 50 IU AB 50 IXM SPG N Ordering details Type Entry thread Cable gland Blanking plug Weight Order No. for cable Ø (T ambient -0 C to +55 C) AB 50 IU (direct entry) x /4-4 mm Ex-d x /4 Ex-d.6 kg NOR AB 50 IU (direct entry) x /4 x /4 Ex-d.5 kg NOR AB 50 IXM (indirect entry) x M5 x.5-4 mm Ex-e x M5 x.5 Ex-e. kg NOR AB 50 IXM (indirect entry) x M5 x.5 x M5 x.5 Ex-e. kg NOR SPG N (portable light fixture) x /4-4 mm Ex-d. kg NOR (T ambient -50 C to +55 C) AB 50 IU (direct entry) x /4 x /4 Ex-d.6 kg NOR AB 50 IXM (indirect entry) x M5 x.5 x M5 x.5 Ex-e. kg NOR Lamps and fixing accessories are not included Accessories AB 50/SPG N Type Content Application Order No. REP AB 50 Spare glass AB 50 NOR WG Wire guard, galvanized AB 50 NOR ER External reflector, coated AB 50 NOR CEV / AB Eye bolt galvanized AB 50 NOR AS. EV Ceiling bracket, galvanized AB 50 NOR Metal cable glands see page Dimensions drawing Polar curve Ø5 Ø5 5 AB 50 IU AB 50 IXM SPG N entry optional entry, on request Polar 0 curve 0 AB 50 IU C 0 C l/cd/klm Dimensions in mm 4. COOPER CROUSE-HINDS GMBH

13 I Ex-Pendant light fittings I Technical data AB 5 M/S...V AB 5 IX AB 5 IU AB 5 IU AB 5 IX AB 5 M/S... Marking to 4//EC II G Ex de IIC T ) (indirect entry IX) / Ex d IIC T ) (direct entry) ) (new standard applied for) II D Ex td A IP6 T ) C EC-Type Examination Certificate LOM 0 ATEX 00 X IECEx Certificate of Conformity IECEx BKI 0.008X Marking acc. to IECEx Ex d/de IIC T ) Ex td A IP6 T ) Permissible ambient temperature -0 C to +55 C -45 C to +55 C (AB 5 M/S) -50 C to +55 C (option) Rated voltage max. 50 V (AB 5..) / 0 V AC AB 5 M/S ) Power factor cos ϕ 0.85 (AB 5 M/S) Connecting terminals x.5 mm / x.5 mm (IU), x.5 mm (IX and M/S), PE ext. x 6 mm Insulation class Lamp/Illuminant ) Lamp cap E ) ) Rated luminous flux Light efficiency in operation 5 % Degree of protection accd. EN 5 Cable glands/gland plates/enclosure drilling x /4 ISO /-thread (Ex-d), one plugged (UI and M/S) / Dimensions (L x W x H) Weight Type of mounting Enclosure material Enclosure colour Protective cover/protective bowl Additional lamp data I IP6 x M5 x.5 one plugged (IX) mm x Ø 05 mm (IU), 400 x Ø 05 mm (IX), 45 x Ø 05 (M/S) see ordering information ceiling mounting light alloy grey borosilicate glass Lamp Luminous Power Temperature class II G Max. surface temp. II D flux ) Tambient 40 C Tambient > 40 C Tambient 40 C Tambient > 40 C Incandescent IGA lm 50 W T T T C T 4 C Incandescent IGA lm 00 W T T T C T 5 C Halogene lamp IQT 00 lm 5 W T5 T4 T 88 C T 0 C Halogene lamp IQT 500 lm 50 W 4) T4 T T C T 8 C Compact Fuorescent Lamp TC-TSE 00/00 lm 5-0 W 5) T6 T6 T C T 5 C High pressure mercury vapor mixed light HME-SB 00 lm 00 W T4 T4 T 0 C T 5 C High pressure mercury vapor mixed light HME-SB 00 lm W T T T C T 4 C High pressure mercury vapor HME 800 lm 80 W T4 T4 T C T C High pressure mercury vapor HME 0 lm 5 W T T T C T 4 C High pressure sodium lamp HSE 400 lm 50 W T5 T4 T 86 C T 0 C High pressure sodium lamp HSE 50 lm 0 W T4 T4 T C T C ) see table ) depends on lamp 0 ) others on request 4) Tamp max. +40 C 5) Tamp max. +0 C COOPER CROUSE-HINDS GMBH 4.

14 I Ex-Pendant light fittings I AB 5 IU AB 5 IX AB 5 M/S...V Ordering details Type Lamp Entry thread Cable gland Blanking plug Weight Order No. for cable Ø (T ambient -0 C up to +55 C) AB 5 IU (direct entry) all x /4 x /4 Ex-d.6 kg NOR AB 5 IX (indirect entry) all x M5 x.5 x M5 Ex-e 4.5 kg NOR AB 5 M 5 V (direct entry) ) 5 W HME x /4 x /4 Ex-d.5 kg NOR AB 5 S 0 V (direct entry) ) 0 W HSE x /4 x /4 Ex-d.5 kg NOR (T ambient -50 C up to +55 C) AB 5 IU (direct entry) all x /4 x /4 Ex-d.6 kg NOR AB 5 IX (indirect entry) all x M5 x.5 x M5 Ex-e 4.5 kg NOR (T ambient -45 C up to +55 C) AB 5 M 5 V (direct entry) ) 5 W HME x /4 x /4 Ex-d.5 kg NOR AB 5 S 0 V (direct entry) ) 0 W HSE x /4 x /4 Ex-d.5 kg NOR Lamps and fixing accessories are not included ) including flameproof enclosure with complete control gear Accessories AB 5 Content Application Order No. Spare glass with metal ring AB 5 NOR Wire guard AB 5 NOR External reflector AB 5 NOR Ceiling bracket ANSI 6 AB 5 NOR Eye bolt ANSI 6 AB 5 NOR Dimensions drawing Polar curve Ø0 Ø0 Ø0 optional entry, on request entry AB 5 IU AB 5 IX AB 5..V Polar curve AB 5 IU C l/cd/klm Dimensions in mm 4.4 COOPER CROUSE-HINDS GMBH

15 I Ex-Pendant light fittings I EVI 500 XM Technical data EVI 500 UD EVI 00 XM EVI 00 UD EVI 00 EVI 500 Marking to 4//EC II G Ex d IIC T ) (direct entry UD) (new standard applied for) II G Ex de IIC T ) (indirect entry XM) II D Ex td A IP6 T ) C EC-Type Examination Certificate LOM 0 ATEX 0 X IECEx Certificate of Conformity IECEx BKI 0.00X Marking acc. to IECEx Ex d / de IIC T ) Ex td A IP6 T ) Permissible ambient temperature -0 C to +55 C -50 C to +55 C Rated voltage max. 50 V Connecting terminals x.5 mm / x.5 mm (UD), x.5 mm (XM); PE ext. x 6 mm Insulation class I Lamp/Illuminant ) Lamp cap E (EVI 00) / E 40 (EVI 500) Rated luminous flux ) Light efficiency in operation 5 % Degree of protection accd. EN 5 IP6 Cable glands/gland plates/enclosure drilling x /4 ISO /-thread (Ex-d), one plugged (UD) / x M5 x.5, on plugged (XM) Dimensions (L x W x H) 80 mm x Ø 45 mm (00 UD), 400 x Ø 5 mm (00 XM) 40 mm x Ø 00 mm (500 UD), 4 x Ø 00 mm (500 XM) Weight see ordering information Type of mounting ceiling mounting Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass Additional lamp data Lamp Luminous Power Type Temperature class II G Max. surface temp. II D flux ) Tambient +40 C Tambient +55 C Tambient +40 C Tambient +55 C Incandescent IGA lm 50 W EVI 00 T4 T4 T05 ºC T0 ºC Incandescent IGA lm 00 W EVI 00 T4 T4 T5 ºC T0 ºC Incandescent IGA lm 00 W EVI 500 T4 T4 T5 ºC T0 ºC Incandescent IGA lm 500 W EVI 500 T T T55 ºC T0 ºC High pressure mercury vapor mixed light HME-SB 00 lm W EVI 00 T4 T T5 ºC T40 ºC High pressure mercury vapor mixed light HME-SB 50 lm 50 W EVI 500 T4 T T5 ºC T40 ºC High pressure mercury vapor HME 800 lm 80 W EVI 00 T4 T4 T5 ºC T0 ºC High pressure mercury vapor HME 0 lm 5 W EVI 00 T4 T4 T5 ºC T0 ºC High pressure mercury vapor HME 000 lm 50 W EVI 500 T4 T T5 ºC T40 ºC High pressure sodium lamp HSE 50 lm 0 W EVI 00 T5 T4 T 5 ºC T0 ºC High pressure sodium lamp HSE 4000 lm 50 W EVI 500 T5 T4 T 0 ºC T05 ºC High pressure sodium lamp HSE 5000 lm 50 W EVI 500 T4 T4 T5 ºC T40 ºC High pressure Metal Halide HIE 000 lm 50 W EVI 500 T4 T T5 ºC T40 ºC ) see table 0 ) depends on lamp COOPER CROUSE-HINDS GMBH 4.5

16 I Ex-Pendant light fitting I EVI 00 UD EVI 00 XM EVI 500 UD EVI 500 XM Ordering details Type ) Entry thread Cable gland Blanking plug Weight Order No. for cable Ø kg (T ambient -0 C to +55 C) EVI 00 UD (direct entry) x /4-4 mm Ex-d x /4 Ex-d 8.0 NOR EVI 00 UD (direct entry) x /4 x /4 Ex-d 8.0 NOR EVI 500 UD (direct entry) x /4-4 mm Ex-d x /4 Ex-d.0 NOR EVI 500 UD (direct entry) x /4 x /4 Ex-d.80 NOR EVI 00 XM (indirect entry) x M5 x.5-4 mm Ex-e x M5 Ex-e.0 NOR EVI 00 XM (indirect entry) x M5 x.5 x M5 Ex-e.00 NOR EVI 500 XM (indirect entry) x M5 x.5-4 mm Ex-e x M5 Ex-e.0 NOR EVI 500 XM (indirect entry) x M5 x.5 x M5 Ex-e. NOR (T ambient -50 C to +55 C) EVI 00 UD (direct entry) x /4 x /4 Ex-d 8.0 NOR EVI 500 UD (direct entry) x /4 x /4 Ex-d.80 NOR EVI 00 XM (direct entry) x /4 x /4 Ex-d.00 NOR EVI 500 XM (direct entry) x /4 x /4 Ex-d. NOR ) Versions for high pressure lamps (HME, HSE, HIE): flameproof ballast enclosure not included Lamps and fixing accessories are not included Accessories EVI 00, EVI 500 Type Content Application Order No. REP 00 Spare Glass EVI 00 NOR REP 500 Spare glass EVI 500 NOR G. EV 00 Wire Guard EVI 00 NOR G. EV 500 Wire Guard EVI 500 NOR PC. EV 00 External reflector EVI 00 / EVQ 55 NOR PC. EV 500 External reflector EVI 500 / EVQ 85 NOR KEY, EV Lamp key EV... NOR CEV/AB Eye bolt EV... NOR AS. EV Ceiling bracket,adjustable EV... NOR SPU. EV Wall mounting barcket EV... NOR BC. EV Pole mounting bracket EV... NOR SP. EV 00 Wall mounting bracket EVI 00 NOR SP. EV 500 Wall mounting bracket EVI 500 NOR Metal cable glands see page COOPER CROUSE-HINDS GMBH

17 I Ex-Pendant light fitting I EVI 500 UD EVI 500 XM Dimensions drawing Polar curve EVI 00 XM EVI 00 UD Ø 45 entry optional entry, on request Ø 45 Ø 00 Ø 00 5 EVI 00 UD EVI 00 XM EVI 500 UD EVI 500 XM ø 8 BC. EV/AB SP.EV 00/500. /4 KEY.EV CEV/AB AS.EV/AB Polar 0 curve EVI 00/500 0 without external reflector /4 ø Polar curve EVI 00/500 with external reflector C 0 C l/cd/klm 5 C l/cd/klm Dimensions in mm COOPER CROUSE-HINDS GMBH 4.

18 I Ex-Pendant light fitting I EVQ 55 UD EVQ 55 XM EVQ 85 UD EVQ 85 XM Technical data EVQ QL-lamps Marking to 4//EC II G Ex d IIC T6 (direct entry UD) (new standard applied for) II G Ex de IIC T6 (indirect entry XM) II D Ex td A IP6 T85 C EC-Type Examination Certificate LOM 0 ATEX 0 X IECEx Certificate of Conformity IECEx BKI 0.00X Marking acc. to IECEx Ex d / de IIC T6 Permissible ambient temperature -0 C to +55 C Rated voltage 0 V AC/DC Rated current 0.6 A (55 W), 0.40 A (85 W) Frequency 50/ Hz Power factor cos ϕ > 0.6 Circuit electronic HF generator Connecting terminals x.5 mm / x.5 mm (UD), x.5 mm (XM); PE ext. x 6 mm Insulation class I Lamp/Illuminant Induction lamp 55/85 W with coupler Rated luminous flux 55 W: 500 lm / 85 W: 00 lm Light efficiency in operation 66 % Degree of protection accd. EN 5 IP6 Cable glands/gland plates/enclosure drilling x /4 ISO /-thread (Ex-d), one plugged (UD), x M5 thread (Ex-e), one plugged (XM) Dimensions (L x W x H) 80 mm x Ø 45 mm (55 UD), 400 x Ø 5 mm (55 XM), 40 mm x Ø 00 mm (85 UD), 4 x Ø 00 mm (85 XM), Weight see ordering information Type of mounting ceiling mounting Enclosure material light alloy Enclosure colour grey, PTFE (optional) Protective cover/protective bowl borosilicate glass, opaque (clear on request) Fixing accessories are not included, included lamps and HF generator 4.8 COOPER CROUSE-HINDS GMBH

19 I Ex-Pendant light fitting I EVQ 85 XM Ordering details EVQ 85 UD EVQ 55 XM EVQ 55 UD Type Entry thread Cable gland Blanking plug Weight Order No. for cable Ø EVQ 55 UD (direct entry x /4-4 mm Ex-d x /4 Ex-d.0 NOR EVQ 55 UD (direct entry x /4 x /4 Ex-d.00 NOR EVQ 85 UD (direct entry x /4-4 mm Ex-d x /4 Ex-d. NOR EVQ 85 UD (direct entry x /4 x /4 Ex-d.8 NOR EVQ 55 XM (indirect entry x M5 x.5-4 mm Ex-e x M5 Ex-e.0 NOR EVQ 55 XM (indirect entry x M5 x.5 x M5 Ex-e.80 NOR EVQ 85 XM (indirect entry x M5 x.5-4 mm Ex-e x M5 Ex-e.0 NOR EVQ 85 XM (indirect entry x M5 x.5 x M5 Ex-e. NOR Accessories EVQ 55, EVQ 85 Type Content Application Order No. G. EV 00 Wire Guard EVQ 55 NOR G. EV 500 Wire Guard EVQ 85 NOR PC. EV 00 External reflector EVI 00 / EVQ 55 NOR PC. EV 500 External reflector EVI 500 / EVQ 85 NOR KEY, EV Lamp key EV... NOR CEV/AB Eye bolt EV... NOR AS. EV Ceiling bracket, adjustable EV... NOR SPU. EV Wall mounting barcket EV... NOR BC. EV Pole mounting bracket EV... NOR SP. EV 00 Wall mounting bracket EVQ 55 NOR SP. EV 500 Wall mounting bracket EVQ 85 NOR Metal cable glands see page Dimensions drawing Polar curve kg EVQ 55 UD Ø 45 entry optional entry, on request 400 Dimensions for Accessories see page 5. Ø Ø 00 EVQ 55 XM EVQ 85 UD EVQ 85 XM 4 Ø 00 0 Polar curve EVQ 55/85 without external reflector C 0 C l/cd/klm Polar curve EVQ 55/85 with external reflector C 0 C COOPER CROUSE-HINDS GMBH 4. 0 l/cd/klm Dimensions in mm

20 I Ex-Pendant light fitting I EV ZM EV ZM Technical data EVM EVS EVH Marking to 4//EC II G Ex de IIC T ) (new standard applied for) II D Ex td A IP66 T ) C EC-Type Examination Certificate LOM 0 ATEX 0 X IECEx Certificate of Conformity IECEx BKI 0.00X Marking acc. to IECEx Ex de IIC T ) Ex td A IP6 T ) Permissible ambient temperature -0 C to +55 C -45 C to +55 C (option) Rated voltage 0 V AC ) Rated current ) Frequency 50 Hz ) Power factor cos ϕ > 0.85 Circuit electromagnetic circuit Connecting terminals x ( x.5 mm ); PE extern. x 6 mm Insulation class I Lamp cap E (EV ), E 40 (EV ) Light efficiency in operation 6 % Degree of protection accd. EN 5 IP6 Cable glands/gland plates/enclosure drilling x M5 threads (Ex-e), one plugged Dimensions (L x W x H) 480 mm x Ø 45 mm (EV ZM) 5 mm x Ø 00 mm (EV ZM Weight see ordering information Type of mounting ceiling mounting Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass ) see ordering details ) other voltages or frequencies on request Additional lamp data Lamp Luminous Power Type Temperature class II G Max. surface temp. II D flux ) Tambient 40 C Tambient > 40 C Tambient 40 C Tambient > 40 C High pressure mercury vapor HME 0 lm 5 W EVM 5 ZM T4 T4 T5ºC T0ºC High pressure mercury vapor HME 000 lm 50 W EVM 50 ZM T4 T T5ºC T40 C High pressure sodium lamp HSE 50 lm 0 W EVS 0 ZM T5 T4 T5ºC T0ºC High pressure sodium lamp HSE 4000 lm 50 W EVS 50 ZM T5 T4 T0ºC T05ºC High pressure sodium lamp HSE 5000 lm 50 W EVS 50 ZM T4 T4 T5ºC T0ºC High pressure Metal Halide HIE 000 lm 50 W EVH 50 ZM T4 T T5ºC T40ºC ) depends on used lamps 4.0 COOPER CROUSE-HINDS GMBH

21 I Ex-Pendant light fitting I Ordering details EV ZM EV ZM Type Lamp Rated current Cable gland Ex-e Weight Order No. for cable Ø kg (T ambient -0 C to +55 C) EVM 5 ZM HME 5W.0 A -4 mm 4. NOR EVM 5 ZM HME 5W.0 A 4.0 NOR EVM 50 ZM HME 50W.0 A -4 mm.4 NOR EVM 50 ZM HME 50W.0 A.5 NOR EVS 0 ZM HSE 0W 0.5 A -4 mm 4. NOR EVS 0 ZM HSE 0W 0.5 A 4.0 NOR EVS 50 ZM HSE 50W 0.6 A -4 mm.4 NOR EVS 50 ZM HSE 50W 0.6 A.4 NOR EVS 50 ZM HSE 50W.0 A -4 mm.4 NOR EVS 50 ZM HSE 50W.0 A.4 NOR EVH 50 ZM HIT 50W.80 A -4 mm.4 NOR EVH 50 ZM HIT 50W.80 A.4 NOR (T ambient -45 C to +55 C) EVM 5 ZM HME 5 W 0.6 A 4.0 NOR EVM 50 ZM HME 50 W 0.6 A.4 NOR EVS 0 ZM HSE 0 W.0 A 4.0 NOR EVS 50 ZM HSE 50 W.0 A.4 NOR EVS 50 ZM HSE 50 W.80 A.4 NOR EVH 50 ZM HIT 50 W.80 A.4 NOR Lamps and fixing accessories are not included COOPER CROUSE-HINDS GMBH 4.

22 I Ex-Pendant light fitting I EV ZM EV ZM Accessories EVM, EVS, EVH Type Content Application Order No. REP 00 Space glass EV NOR REP 500 Spare glass EV NOR G. EV 00 Wire guard EV NOR G. EV 500 Wire guard EV NOR PC. EV 00 External reflector EV NOR PC. EV 500 External reflector EV NOR KEY, EV Lamp key EV.. NOR CEV/AB Eye bolt EV.. NOR AS. EV Ceiling bracket, adjustable EV.. NOR SPU. EV Ø mm Wall mounting barcket EV.. NOR BC. EV Pole mounting bracket EV.. NOR SP. EV 00 Wall mounting bracket EV NOR SP. EV 500 Wall mounting bracket EV NOR Metal cable glands see page Dimensions drawing entry Ø 45 Ø EV ZM EV ZM BC. EV 40 0 /4 ø ø SP.EV 00/ /4 KEY.EV CEV/AB AS.EV Polar curve EV 00/500 without external reflector 0 0 Polar curve EV 00/500 with external reflector C 0 C l/cd/klm 5 45 C l/cd/klm Dimensions in mm 4. COOPER CROUSE-HINDS GMBH

23 COOPER CROUSE-HINDS GMBH 4.

24 E X - P E N D A N T L I G H T F I T T I N G S dhls for high pressure discharge lamps Metal version for Zone / The explosion-protected pendant light fittings dhls for high pressure discharge lamps are in accordance to the ATEX-Directive 4//EG. They are certified for use in the Zones and. The housing is made of a light alloy with a powdered coating. The pressed-in thread-ring for the flameproof thread gap is made of brass. This provides for an easy lamp replacement even after a longer operating periods. The pendant light fitting is designed for outdoor use. Due to the high safety standard it has more than proven its reliability in chemical factories and offshore platforms for illuminating large areas and selective large objects. The light fitting is fitted with a dome-shaped glass cover and can also be fitted with an external reflector. Cost-effective illumination of large objects For use in chemical factories and offshore platforms Robust light alloy housing with a powdered coating Easy lamp replacement even after extended time of operation Or with an external reflector 4.4

25 I Ex-Pendant light fittings I Technical data dhls dhls 8550 dhls Marking to 4//EC II G Ex de IIC T EC-Type Examination Certificate DMT 0 ATEX E 0 IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIC T Permissable ambient temperature 0 C to +50 C / 0 C to +55 C (50 W) 45 C to +55 C (option) Rated voltage 0 V AC Rated current ) Frequency 50 Hz Power factor cos ϕ 0.5 ind. / 0. comp. Circuit inductive circuit / compensated circuit Connecting terminals L + N + PE; x.5 mm Insulation class I Lamp/Illuminant high pressure mercury vapour lamp HME 50 W / 400 W high pressure sodium lamp HSE 50 W / 400 W Lamp cap E 40 acc. IEC 8 Light efficiency in operation % 55 % (AR) ) Degree of protection accd. EN 5 IP65 Cable glands/gland plates/enclosure drilling x M5 x.5 for cables from Ø 8 - mm x M5 x.5 with blanking plug Dimensions (L x W x H) 50 x Ø 0 mm (without compensation box) 80 x Ø 0 mm (with compensation box) Weight approx. 0 kg approx. kg with compensation box Enclosure material light alloy with powder coating, grey Protective cover/protective bowl borosilicate glass ) see table ) AR = external reflector COOPER CROUSE-HINDS GMBH 4.5

26 I Ex-Pendant light fittings I dhls Ordering details Type Lamp Rated luminous flux ) Rated current Power factor cos Order No. dhls W HME 000 lm. A 0,5 ind. CGS 8688 P W HME 000 lm. A 0, comp. CGS 8688 P00 50 W HSE 5000 lm.0 A 0,5 ind. CGS 8688 P00 50 W HSE 5000 lm.5 A 0, comp. CGS 8688 P00 dhls W HME 000 lm.5 A 0,5 ind. CGS 888 P W HME 000 lm.5 A 0, comp. CGS 888 P W HSE 4000 lm 4.4 A 0,5 ind. CGS 888 P W HSE 4000 lm.0 A 0, comp. CGS 888 P00 Lamps and fixing accessories are not included ) depends on used lamps Accessories dhls 8550 dhls Type Content Order No. EB Eye bolt, M0 (0 pcs.) galvanized GHG R000 L 8 Mounting bracket for inductive version GHG R000 L 40 Mounting bracket for compensated version GHG R000 AR External reflector, metal, white powder coated CGS 0 P000 Dimensions drawing ring bolts Ø 0 Ø 500 dhls ind Compensation box Ø 0 Ø 500 dhls komp M0, 8 deep Polar curve with external reflector dhls 0 C 0 C l/cd/klm Polar curve without external reflector dhls X X0 L 8 L C 0 C l/cd/klm Dimensions in mm 4.6 COOPER CROUSE-HINDS GMBH

27 COOPER CROUSE-HINDS GMBH 4.

28 E X - F L O O D L I G H T S FZD 04 and FZD EN for High Pressure Discharge Lamps Metal Design for Zone / The explosion-protected floodlight FZD 04 for high-pressure discharge lamps meets the requirements of the ATEX directive 4//EC. The modular floodlight FZD 04 comprises an Ex-e housing for the starter and a separate mounted Ex-e enclosure with ballast and the p.f. correction capacitor. The floodlight enclosure made of high grade aluminium and stainless steel components is a light weight, which can be installed easily by a single electrician without need of a crane or other heavers. All main components are certified separa tely as components. The flameproof lamp module can easily be separated from the housing once a screw has been loosened. Two sealing systems of degree of protection IP66 ensure permanently protected Ex-d contacts. There is no need to switch off the mains voltage to separate the module from the luminaire. This means that a simple lamp change and easy cleaning of the lamp modules possible, even outside the potentially explosive atmos - pheres. Optionally, the module can be used with narrow-angle and wide-angle reflectors even retrospectively and without any compli - cated installation. By simply and quickly exchanging the lampmodule, changing the lamp is not a problem, even in extreme weather or climate conditions. The FZD EN combines the easy lamp replacement with a compact enclosure. All components are protected in one Ex-d enclosure. All advantages of easy re-lamping and easy maintenance are same with FZD 04. Simple lamp change by the Ex-d lamp module Modular Ex-e/Ex-d housing High degree of protection IP66 Internal wide-angle- or, optionally, narrow-angle reflector For low ambient temperatures of up to -45 C 4.8

29 I Ex-Floodlight I Technical data Ballast enclosure Floodlight enclosure FZD 04 Marking to 4//EC II G Ex demq IIC T ) II D Ex td A IP66 T ) EC-Type Examination Certificate PTB 0 ATEX 58 IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIC T or T4 Ex td A IP66 T ) C Permissible ambient temperature -45 C to + C ) Rated voltage 0 V AC ) Rated current ) Frequency 50 Hz ) Power factor cos ϕ > 0. Circuit compensated circuit Insulation class I Degree of protection accd. EN 5 IP66 Lamp module Floodlight enclosure Type of protection Lamp module: Ex d IIC Floodlight enclosure: Ex em IIC Connecting terminals x ( x.5 mm ) +.5 mm PE Lamp/Illuminant High pressure sodium lamp tubular (HST) Metal halide lamp tubular (HIT) Lamp cap E 40 acc. EN 06- Light efficiency in operation 66 % Cable glands/gland plates/enclosure drilling x M5 x.5 with plastic cable glands Ex-e M5 for non-armoured cable Ø 8 - mm ) option with metal thread M0, without cable gland Weight Lamp module lamp: approx. 0.6 kg Floodlight enclosure: approx. 4. kg Enclosure earth.5 mm PE Ballast enclosure Type of protection Ex emq IIC Connecting terminals x ( x 4 mm ) + 4 mm PE Cable glands/gland plates/enclosure drilling x M5 x.5, x M5 plastic cable grand Ex-e for cable Ø 8 - mm M5 for one plugged 4) Weight approx. kg (polyester fiberglass) approx. 0 kg (stainless steel) Enclosure material Polyester reinforced fiber glass, or stainless steel ) ) see table ) other voltages or frequencies on request 0 ) Connection to the ballast enclosure 4) One to connect to the floodlight enclosure, the others for the mains connection 5) mounting position ± 5, see instruction Additional lamp data Lamp Rated Temperature class II G Max. surface temp. II D current Tamb. +40 C Tamb. +50 C Tamb. + C Tamb. +40 C Tamb. +50 C Tamb. + C HST / HIT 50 W 0,8 A T4 T4 T T 0 ºC T 0 ºC T 40 ºC HST / HIT 50 W, A T4 5) /T T T 0 ºC 5) /T 50 ºC T ºC HST / HIT 400 W, A T T 80 ºC COOPER CROUSE-HINDS GMBH 4.

30 I Ex-Floodlight I Floodlight enclosure Ballast enclosure Ordering details FZD 04 Lamp Rated luminous flux ) Light distribution Order No. Ballast enclosure made of polyester with cable gland for mains connection 50 W HIT/HST 000 lm / 5000 lm narrow beam NOR W HIT/HST 000 lm / 5000 lm wide beam NOR W HIT 5000 lm narrow beam NOR W HIT 5000 lm wide beam NOR W HST lm narrow beam NOR W HST lm wide beam NOR Ballast enclosure made of stainless steel with cable gland for mains connection 50 W HIT/HST 000 lm / 5000 lm narrow beam NOR W HIT/HST 000 lm / 5000 lm wide beam NOR W HIT 5000 lm narrow beam NOR W HIT 5000 lm wide beam NOR W HST lm narrow beam NOR W HST lm wide beam NOR Ballast enclosure made of polyester without cablegland for mains connection 50 W HIT/HST 000 lm / 5000 lm narrow beam NOR W HIT/HST 000 lm / 5000 lm wide beam NOR W HIT 5000 lm narrow beam NOR W HIT 5000 lm wide beam NOR W HST lm narrow beam NOR W HST lm wide beam NOR Ballast enclosure made of steel without cablegland for mains connection 50 W HIT/HST 000 lm / 5000 lm narrow beam NOR W HIT/HST 000 lm / 5000 lm wide beam NOR W HIT 5000 lm narrow beam NOR W HIT 5000 lm wide beam NOR W HST lm narrow beam NOR W HST lm wide beam NOR ) depends on used lamps 4.0 COOPER CROUSE-HINDS GMBH

31 I Ex-Floodlight I Technical data FZD EN FZD EN Marking to 4//EC II G Ex demq IIC T ) II D IP66 T ) EC-Type Examination Certificate PTB 0 ATEX 58 IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIC T or T4 Ex td A IP66 T ) C Permissible ambient temperature -45 C to +50 C ) Rated voltage 0 V AC ) Rated current 50 W:. A / 400 W:. A Frequency 50 Hz ) Power factor cos ϕ > 0. Circuit compensated circuit Insulation class I Lamp/Illuminant High pressure sodium lamp - tubular (HST) Metal halide lamp - tubular (HIT) 50 W or 400 W Lamp cap E 40 acc. EN 06- Light efficiency in operation 66 % Degree of protection accd. EN 5 IP66 Cable glands/gland plates/enclosure drilling x M5 x.5 with plastic cable gland Ex-e M5 for non-armoured cable Ø 8 - mm, other plugged; option: with metal thread M0, without cable gland Dimensions (L x W x H) 5 x 0 x 50 mm Weight 8 kg (enclosure); kg lamp module Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl die-cast light alloy Options tempered safety glass Enclosure earth.5 mm PE ) see table ) other voltages or frequencies on request Additional lamp data Lamp Temperature class II G Max. surface temp. II D Ordering details Tambient up to +40 C Tambient up to +50 C Tambient up to +40 C Tambient up to +50 C HST / HIT 50 W T4 5) /T T T 0 ºC 5) /T 50 ºC T ºC HST / HIT 400 W T T 80 ºC 5) mounting position ± 5, see instruction Lamp Rated luminous flux ) Reflector Order No. FZD EN 50 W HIT / HST 000 lm / 5000 lm wide-angle W HIT 5000 lm wide-angle W HST lm wide-angle W HIT / HST 000 lm / 5000 lm narrow-angle W HIT 5000 lm narrow-angle W HST lm narrow-angle ) depends on lamp Delivery without lamp, incl. mounting bracket COOPER CROUSE-HINDS GMBH 4. 0

32 I Ex-Floodlight I Lamp module Slip fitter Mounting plate Swivel bracket Accessories FZD 04 Type Content FZD 04 FZD EN Order No. Lamp module Lamp module 50 W/400 W complete with internal reflector, narrow-angle reflector X X wide-angle reflector X X Slip fitter fitter for pole /4 mounting complete with fixing screws X NOR Slip fitter fitter for pole mounting complete with fixing screws X NOR Swivel bracket Ajustable hinge for wall/pole mounting X NOR Mounting plate Stainless steel plate for wall or pole installation (using pipe clamps, not incl.) X NOR Pipe clamp /4 pipe clamp ( pcs) galvanized Ø 8-4 mm X Pipe clamp /4 pipe clamp ( pcs) stainless steel Ø 8-4 mm X Pipe clamp / pipe clamp ( pcs) galvanized Ø 4-5 mm X Pipe clamp pipe clamp ( pcs) galvanized Ø 56 - mm X Lamps and fixing accessories are not included Metal cable glands see page Polar curve Polar curve FZD... with wide beam reflector Polar curve FZD... with narrow beam reflector C 0 C l/cd/klm C 0 C l/cd/klm 4. COOPER CROUSE-HINDS GMBH

33 I Ex-Floodlight I Swivel bracket Mounting plate Slip fitter Lamp module Dimensions drawing 50/400 W: Ø X 4 X Ø Ballast enclosure: plastic X FZD 04 50/400 W X Swivel bracket 8, 6,6 0 Ballast enclosure: stainless steel, Ø Slip fitter , Mounting plate COOPER CROUSE-HINDS GMBH 4. 0 Dimensions in mm 0

34 E X - F L O O D L I G H T PX 04 for high pressure discharge lamps Metal version for Zone / The explosion-protected floodlight PX 04 for high pressure discharge and halogen lamps are in accordance to the ATEX-Directive 4//EG. They are certified for use in the Zones,, and. The light fitting housing is made of copper-free aluminium, the glass cover of a mechanical and thermal resistant borosilicate glass. All external screws are made of stainless steel. The electrical components are thermically separated in their own compartment and have a separate Ex-e maintenance-friendly connection compartment. With the adjustable mounting frame an optimum on light guidance is reached. Due to the robust architecture it has more than proven its reliability in chemical factories and offshore platforms for illuminating large areas and selective large objects. For environmental temperatures of up to + 55 C Degree of protection IP6 Robust light alloy housing Captive screws made of stainless steel Large Ex-e connection compartment Easy to maintain Easy to install 4.4

35 I Ex-Floodlight I Technical data PX 04 PX Marking to 4//EC II G Ex de IIB T ) II D Ex td A IP6 T ) C EC-Type Examination Certificate BVS 0 ATEX E 50 X IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIB T-T4 Ex td A IP66 T85 C - 0 C Permissible ambient temperature -0 C to +55 C (-55 C up to +55 C optional) Rated voltage with control gear 0 V AC ) without control gear 50 V AC Rated current ) 4 5 Frequency 50 Hz ) Power factor cos ϕ > 0.85 Circuit compensated circuit Connecting terminals L, N: x 4 mm; PE: X 6 mm Insulation class I Lamp/Illuminant ) Lamp cap E 40 (E for 0 W HIT and HST, 50 HIT) acc. IEC 8 Light efficiency in operation 6 % Degree of protection accd. EN 5 IP6 Cable glands/gland plates/enclosure drilling Indirect entries: x M5 x.5 with or without cablegrands (see table), one plugged Dimensions (L x W x H) 546 x 44 x 6 mm (with control gear) 546 x 44 x 40 mm (without control gear) Weight approx. kg (with control gear) approx. kg (without control gear) Type of mounting mounting bracket Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass Reflector polished aluminium reflector Enclosure earth x 6 mm ) see table ) other voltages or frequencies on request ) depends on lamp Additional lamp data 6 8 Type Rated luminous Temperature class II G Max. surface temp. II D flux ) Tambient +40 C Tambient +55 C Tambient +40 C Tambient +55 C HS_ - 0 W 00 lm T4 T4 T85 ºC T00 ºC HI_ - 0 W 0 lm T4 T4 T0 ºC T05 ºC HS_ - 50 W 000 lm T4 T4 T5 ºC T0 ºC HI_ - 50 W 4000 lm T4 T4 T05 ºC T0 ºC HS_ - 50 W 000 lm T4 T T0 ºC T45 ºC HI_ - 50 W 0000 lm T4 T T0 ºC T45 ºC HME - 50 W 000 lm T T T50 ºC T65 ºC HST W lm T T T5 ºC T0 ºC HIT W 5000 lm T T T0 ºC T85 ºC HME W 000 lm T T T86 ºC T0 ºC HST - 0 W 0000 lm T T T5 ºC T0 ºC IQT W 0000 lm T T T85 ºC T00 ºC 0 COOPER CROUSE-HINDS GMBH 4.5

36 I Ex-Floodlight I PX 04 Ordering details Type Reflector Lamp Lamp Rated current Ex-e metal cable Order No. gland for cable PX 04 narrow beam High pressure sodium lamp HST 0 W. A Ø - 4 mm NOR PX 04 narrow beam High pressure sodium lamp HST 0 W. A NOR PX 04 wide beam High pressure sodium lamp HST 0 W. A Ø - 4 mm NOR PX 04 wide beam High pressure sodium lamp HST 0 W. A NOR PX 0440S narrow beam High pressure sodium lamp HS_ 400 W ).0 A Ø - 4 mm NOR PX 0440S narrow beam High pressure sodium lamp HS_ 400 W ).0 A NOR PX 0440S wide beam High pressure sodium lamp HS_ 400 W ).0 A Ø - 4 mm NOR PX 0440S wide beam High pressure sodium lamp HS_ 400 W ).0 A NOR PX 0440H narrow beam High pressure metal halide HI_ 400 W ).8 A Ø - 4 mm NOR PX 0440H narrow beam High pressure metal halide HI_ 400 W ).8 A NOR PX 0440H wide beam High pressure metal halide HI_ 400 W ).8 A Ø - 4 mm NOR PX 0440H wide beam High pressure metal halide HI_ 400 W ).8 A NOR PX 0440M narrow beam Mercury vapor HME 400 W NOR PX 045 narrow beam H.P. sodium lamp/metal halide HS_ / HI_50 W.5 A Ø - 4 mm NOR PX 045 narrow beam H.P. sodium lamp/metal halide HS_ / HI_50 W.5 A NOR PX 045 wide beam H.P. sodium lamp/metal halide HS_ / HI_50 W.5 A Ø - 4 mm NOR PX 045 wide beam H.P. sodium lamp/metal halide HS_ / HI_50 W.5 A NOR PX 045M narrow beam Mercury vapor HME 50 W NOR PX 045 narrow beam H.P. sodium lamp/metal halide HS_ / HI_50 W.05 A Ø - 4 mm NOR PX 045 narrow beam H.P. sodium lamp/metal halide HS_ / HI_50 W.05 A NOR PX 045 wide beam H.P. sodium lamp/metal halide HS_ / HI_50 W.05 A Ø - 4 mm NOR PX 045 wide beam H.P. sodium lamp/metal halide HS_ / HI_50 W.05 A NOR PX 040 narrow beam High pressure sodium lamp HS_ 0 W 0.5 A Ø - 4 mm NOR PX 040 narrow beam High pressure sodium lamp HS_ 0 W 0.5 A NOR PX 0405 narrow beam Halogen IQT 500 W. A Ø - 4 mm NOR PX 0405 narrow beam Halogen IQT 500 W. A NOR PX 0405 wide beam Halogen IQT 500 W. A Ø - 4 mm NOR PX 0405 wide beam Halogen IQT 500 W. A NOR ) Valid for lamps HI_ 400 W (4. A) ) Valid for lamps HI_ 400 W (.5 A) Lamps and fixing accessories are not included Accessories PX 04 Type Content Order No. SB Pipe fixing Ø 48 mm to Ø 64 mm NOR ATP Portable stand, painted steel NOR PAH Horizontal steel shade, painted steel NOR PAV Vertical steel shade, painted steel NOR Metal cable glands see page COOPER CROUSE-HINDS GMBH

37 I Ex-Floodlight I Dimensions drawing PX PX 04 without ballast for QT- and HME-SB-Lamps 5 Ø 4 Ø 6 Ø PX 04 with ballast for all high pressure discharge lamps M5 PX optional entry, on request entry Polar curve PX 04 with narrow beam reflector Polar curve PX 04 with wide beam reflector C 0 C l/cd/klm C 0 C l/cd/klm 0 COOPER CROUSE-HINDS GMBH 4. Dimensions in mm

38 E X - F L O O D L I G H T dtls for high pressure discharge lamps Metal version for Zone / The explosion-protected floodlight dtls for high pressure discharge lamps is in accordance to the ATEX-Directive 4//EG. They are certified for use in the Zones and. The housing is made of a light alloy with a powdered coating. The pressed-in thread-ring for the flameproof thread gap is made of brass. This provides for an easy lamp replacement even after a longer operating periods. The floodlight is designed for outdoor use. Due to the high safety standard it has more than proven its reliability in chemical factories and offshore platforms for illuminating large areas and selective large objects. The vaporized reflectors are designed for various angles of dispersion. Cost-effective illumination of large objects For use in chemical factories and offshore platforms Robust light alloy housing with a powdered coating Easy lamp replacement even after extended time of operation Vaporized reflector for various angles of dispersion 4.8

39 I Ex-Floodlights I Technical data dtls dtls 8550 / dtls 8500 Marking to 4//EC II G Ex de IIC T/T4 EC-Type Examination Certificate DMT 0 ATEX E 0 IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIC T4 (0 W) Ex de IIC T (50 W) Permissable ambient temperature 0 C to +50 C Permissable ambient temperature (option) 45 C to +50 C (option) Rated voltage 0 V AC ) Rated current ) Frequency 50 Hz ) Power factor cos ϕ ) Circuit inductive circuit / compensated circuit Connecting terminals L + N + PE; x.5 mm Insulation class I Lamp/Illuminant high pressure metal-halide lamp HIT-DE high pressure sodium vapour lamp HST-DE Lamp cap Fc / Rx s Rated luminous flux ) HIT-DE 50 W: 000 lm HST-DE 50 W: 5000 lm HST-DE 0 W: 6800 lm Light efficiency in operation % 46 % with diffuser lens Degree of protection accd. EN 5 IP65 Cable glands/gland plates/enclosure drilling ) x M5 x.5 for cables from Ø 8 - mm x M5 x.5 with blanking plug Weight approx. 5 kg approx. kg with compensation box Enclosure material light alloy with powder coating, grey Enclosure colour grey Protective cover/protective bowl borosilicate glass ) Other voltages, frequencies or entries on request ) see ordering details Ordering details Type Lamp Rated current Power factor cos ϕ Temperature Order No. class dtls 8550 S with diffusser lens 50 W HIT/HST.0 A 0.4 ind. T CGS 8588 P W HIT/HST.5 A 0. comp. T CGS 8588 P00 dtls 8550 P 50 W HIT/HST.0 A 0.4 ind. T CGS 8588 P000 with parabolic-reflector 50 W HIT/HST.5 A 0. comp. T CGS 8588 P00 dtls 8500 P with reflector 0 W HST 0.5 A 0.5 comp. T4 CGS 8588 P000 Lamps and fixing accessories are not included 0 COOPER CROUSE-HINDS GMBH 4.

40 I Ex-Floodlights I dtls Accessories dtls 8550 Type Application Order No. EB Eye bolt, M0 (0 St.) galvanized GHG R000 L 8 Mounting bracket, for inductive version GHG R000 L 40 Mounting bracket, for compensated version GHG R000 Dimensions drawing ring bolts Compensation box M0, 8 deep Polar curve with parabolic reflector dtls C 0 C l/cd/klm Polar curve with diffuser lens dtls Ø 0 dtls 8550 ind. Ø 0 dtls 8550 komp L 8 L 40 Dimensions in mm X C 0 C l/cd/klm X COOPER CROUSE-HINDS GMBH

41 COOPER CROUSE-HINDS GMBH 4.4

42 E m e r g e n c y U n i t Explosion-protected, modular GHG 664 emergency lighting supply unit with explosion-protected dtls 8500 P floodlight for high-pressure lamp Safety for escape routes and evacuation equipment in the event of an emergency and power failure In the event of a power failure, the new explosion-protected GHG 664 emergency pack enables the battery-supported operation of a 0 W sodium high-pressure lamp for the duration of.5 hours. When used in combination with the powerful explosion-protected dtls 8500 P floodlight, escape routes and evacuation equipment (life boats, life rafts, abseiling equipment or rescue cushions, etc.) can be safely illuminated, even from larger distances. They have been designed especially for offshore use on platforms and ships. Both the GHG 664 emergency pack and the dtls 8500 P floodlight are in explosionprotected design in accordance with the ATEX Directive 4//EC and have been approved for use in Zones and. The emergency pack GHG 664 features a flameproof enclosure for the electronic components and a flanged-on box in the type of protection increased safety that accommodates the battery and the connection terminals. The dtls 8500 P floodlight, which is mounted separately from the emergency pack, features a robust enclosure made of powder-coated aluminium with a borosilicate glass lens, a parabolic reflector for the 0 W sodium vapour high-pressure lamp. Thus, for example, with a luminous spot height of m, it is possible to illuminate an area measuring 5 x 5 m with lx. Suited for use on offshore platforms and ships Safe light for evacuation equipment in hazardous areas Emergency lighting duration of.5 hours in the event of a power failure Large Ex-e connection box to facilitate installation Maintenance-friendly due to simple replacement of lamps and batteries Continuous and standby light with switching-off device (only 0 40 V) 4.4

43 I Emergency Unit I Technical data dtls 8500 GHG 664 GHG 664 Marking to 4//EC II G Ex de IIC T6 EC-Type Examination Certificate PTB 0 ATEX 00 X Permissable ambient temperature 5 C to +40 C Rated voltage 0-40 V AC / Option: 0 V AC Rated frequency 50 - Hz Output voltage 0 V AC Power consumption (charging operation) < 40 VA Nominal output max. 80 VA Circuit electronic converter Insulation class I Battery x V, Ah Rated operating duration (emergency operation).5 h Charging duration (> 0 % C) < 4 h Degree of protection acc. to EN 5 IP66 Weight approx. 48 kg (incl. battery) Enclosure material light alloy with powder coating, grey Floodlight dtls 8500 P Marking to 4//EC II G Ex de IIC T4 EC-Type Examination Certificate DMT 0 ATEX E 0 Permissable ambient temperature 0 C to +50 C Rated voltage 0-40 V, 50 - Hz Connecting terminals L + N + PE; max..5 mm Insulation class I Lamp/Illuminant High pressure sodium lamp HST-DE 0 W Lamp cap RXs Rated luminous flux ) 6800 lm Light efficiency in operation % Degree of protection acc. to EN 5 IP65 Cable glands x M5 x.5 for cables from Ø 8 - mm x M5 x.5 with blanking plug Weight approx. 8 kg Enclosure material light alloy with powder coating, grey Light transmitting cover Borosilicate glass ) depends on lamp 8 Ordering details Type Application Order No. Emergency Unit GHG V AC incl. battery plus dtls 8500 P GHG 6 5 R000 Emergency Unit GHG V AC incl. battery plus dtls 8500 P GHG 6 5 R000 Lamps and fixing accessories are not included Accessories Mounting bracket L8 Type Content Application Order No. L8 Mounting bracket dtls 8500 P GHG R000 COOPER CROUSE-HINDS GMBH 4.4 0

44 I Emergency Unit I GHG 664 dtls 8500 Dimension drawing Polar curve ring bolts Ø8 X 5 Ø 0 dtls 8500 P 64 GHG 664 Polar curve dtls 8500 P C l/cd/klm Dimensions in mm 5 48 Ø4,50 X 6 8, X X0 50 X L COOPER CROUSE-HINDS GMBH

45 COOPER CROUSE-HINDS GMBH 4.45

46 E X - V E S S E L L I G H T F I T T I N G KFL with halogen reflector lamp or W LED Metal version for Zone This explosion-protected tank light fitting KFL is in accordance to the ATEX-Directive 4//EG. It has been certified for use in the Zones, and areas. This powerful tank light fitting is equipped with a high output LED lamp 0-40 V/ W or a high-voltage halogen reflector lamp 0 V/50 W and is especially for use as an inspection lighting at inspection windows of mixers from size DN40 up to DN00. The housing is made of a copper-free aluminium. The aluminium collar has a PTFE (Teflon) coating, additionally it has a viton sealant. Equipped with a special transporting handle the KFL LED can also be used as a maintenance light fixture. With the light fitting holder PR it can be mounted on inspection windows according to DIN 80. Compact architecture Connection ready for 0 V AC With halogen reflector incandescent lamp with 50 W or high-power LED W High illumination Generously dimensioned terminal compartment Mounting onto inspection windows according to DIN

47 I Ex-Tank inspection luminaires KFL 50 I Technical data Type KFL W LED Type KFL KFL 50 KFL W LED Marking to 4//EC II G Ex de IIC T II G Ex de IIC T6 (new standard applied for) II D Ex td A IP66 T40 C II D Ex td A IP66 T80 C EC-Type Examination Certificate LOM 0 ATEX 05 IECEx Certificate of Conformity IECEx BKI Marking acc. to IECEx Ex de IIC T Ex td A IP6 T40 C Permissable ambient temperature 0 C to +55 C 0 C to +55 C Permissable ambient temperature (option) 50 C to +55 C 50 C to +40 C Rated voltage 0 V, 50/ Hz 0-40 V, 50/ Hz Rated current 0.5 A A Power consumption 50 VA 0 VA Connecting terminals x.5 mm ; PE internal and external 6 mm Insulation class I Lamp/Illuminant 50 W high voltage (halogen lamp type W PHILIPS MASTER LED Lamp cap GZ 0 Degree of protection accd. EN 5 Cable glands/gland plates/enclosure drilling Weight Enclosure material Enclosure colour Protective cover/protective bowl Options Ordering details Sylvania included, others on request) IP66 x M5 x.5, one plugged kg light alloy with powder coating grey borosilicate glass 0 W lamp (T4 / T0 C) Type Entry Cable entry Exe Blanking Order No. thread for cable Ø plug (T ambient -0 C to +55 C) KFL 50 W M5-4 mm Ex-e x M5 NOR KFL 50 W M5 x M5 NOR KFL 50 W TIM 0 V - V M5-4 mm Ex-e x M5 NOR KFL 50 W TIM 0 V - V M5 x M5 NOR KFL LED M5 x M5 NOR (T ambient -50 C to +55 C) KFL 50 W M5 x M5 NOR KFL 50 W TIM 0 V - V M5 x M5 NOR (T ambient -50 C to +40 C) KFL LED M5 x M5 NOR Supply with support device as standard (lamp holder PR). Metal cable glands see page Accessories KFL 50 Type Content Application Order No. Lamp Halogene reflector lamp 0 V/50 W KFL 50 NOR Lamp Halogene reflector lamp V/50 W KFL 50 TIM NOR AT transport grip KFL.. NOR PAD antiglare shield KFL.. NOR PI mounting legs out of center KFL.. NOR PI mounting legs bended KFL.. NOR LED-lamp Philips Master LED W KFL W LED NOR COOPER CROUSE-HINDS SA

48 I Ex-Tank inspection luminaires KFL 50 I Typ KFL Dimensions drawing 5 DIN 40/50 DIN Light fixing facility PR DIN 00 DIN 5 Windows, nominal width KFL 50 TIM 80 Polar curve KFL Polar curve KFL W C Dimensions in mm 0 l/cd C l/cd 4.48 COOPER CROUSE-HINDS GMBH

49 COOPER CROUSE-HINDS GMBH 4.4

50 E X - P E N D A N T L I G H T F I T T I N G NVMV for high pressure discharge lamps of up to 400 W Metal version for Zone / The explosion-protected light fittings of the NVMV series are in accordance to the ATEX- Directive 4//EG. They have been built and tested according to the European Standard for Gas-Ex-Areas of Zone classification as well as to EN 64- for use in Dust-Ex-Areas of Zone. The light fittings series NVMV with the small housing is designed for lamps with a rating of 0 W up to 50 W. The large housing is designed for lamps with a rating of 50 W up to 400 W. The transparent part consists of a temperature stable, impact resistant glass globe that refracts the light and which is protected with a safetyguard. The modular architecture allows for a quick and cost-effective installation of the light fittings. For pole mounting, a thread of /4 BSP is integrated in the light fitting. Apart from ceiling mounting, there are versions available for pole mounting (5 angle) and wall mounting. A particularly durable sealing system for use under extreme climatic conditions brings additional reliability. The restricted breathing version allows a high illumination combined with a high temperature classification. Ideal for installation at low or medium heights, for wall, ceiling or pole mounting Compact and light-weight Degree of protection IP66/6 High corrosion resistance Restricted breathing version for temperature classes up to T4 Environmental temperatures up to +55 C 4.50

51 I Ex-Pendant light fitting I Technical data NVMV NVMV NVMV NVMV CHAMP for high pressure discharge lamps up to 400 W Marking to 4//EC II G Ex nr IIC T ) II D Ex td A IP6X T ) Type Examination Certificate applied for Permissable ambient temperature 0 C up to +55 C Rated voltage 40 V/50 Hz (other voltage and frequencies on request) Power factor cos > 0. Connecting terminals L, N and PE; max. x.5 mm Insulation class I Lamp cap E (0 W HSE, 5 W HME, 50 HIE) E 40 (50 HSE W HSE/HME) Light efficiency in operation 4 % ( 0-50 W) 8 % ( W) Degree of protection accd. EN 5 IP6/66 Cable glands/gland plates)enclosure drilling Drilling 4 x M5 x.5 with blanking plug Dimensions (L x W x H) 40 x 4 x 8 mm (0-50 W) 555 x 4 x 8 mm ( W) Weight see ordering details Enclosure material light alloy with epoxy powder coating Enclosure colour grey Protective cover/protective bowl borosilicate glass Additional lamp data Lamp Power Rated luminous Temperature class II G Surface temperature II D flux ) -0 C up to +55 C -0 C up to +55 C NVMV (smalling housing) HSE ) 0 W 5.0 lm T4 0 C HSE ) 50 W lm T 5 C HME 4) 5 W 6.00 lm T 5 C HIE 5) 0 W 5.00 lm T4 0 C HIE 5) 50 W.500 lm T 5 C NVMV (large housing) HSE ) 50 W lm T 5 C HSE ) 400 W lm T 5 C HME 4) 50 W.000 lm T 5 C HIE 5) 50 W.000 lm T 5 C HIE 5) 400 W.000 lm T 0 C ) see table ) depents on used lamps 8 0 ) HSE = High pressure sodium lamp 4) HME = High pressure mercury vapor 5) HIE = High pressure metal halide lamp COOPER CROUSE-HINDS GMBH 4.5

52 I Ex-Pendant light fitting I NVMV NVMV NVMV Ordering details Type Mounting HSE HME HIE Weight Order No. (approx. kg) NVMV... (small enclosure) SMC06P000 Ceiling 0 W SMC56P000 Ceiling 50 W HMC6P000 Ceiling 5 W MMC06P000 Ceiling 0 W MMC56P000 Ceiling 50 W SMW06P000 Wall 0 W SMW56P000 Wall 50 W HMW6P000 Wall 5 W MMW06P000 Wall 0 W MMW56P000 Wall 50 W S4BJ06P000 Thread* /4, BSP 0 W S4BJ56P000 Thread* /4, BSP 50 W H4BJ6P000 Thread* /4, BSP 5 W M4BJ06P000 Thread* /4, BSP 0 W M4BJ56P000 Thread* /4, BSP 50 W NVMV... (large enclosure) SMC56PL00 Ceiling 50 W SMC406PL00 Ceiling 400 W HMC56PL00 Ceiling 50 W MMC56PL00 Ceiling 50 W MMC406PL00 Ceiling 400 W SMW56PL00 Wall 50 W SMW406PL00 Wall 400 W HMW56PL00 Wall 50 W MMW56PL00 Wall 50 W MMW406PL00 Wall 400 W S4BJ56PL00 Pole 50 W S4BJ406PL00 Pole 400 W H4BJ56PL00 Pole 50 W M4BJ56PL00 Pole 50 W M4BJ406PL00 Pole 400 W *Thread for /4 BSP pole mounting Lamps and fixing accessories are not included Accessories NVMV CHAMP Type Content Order No. RD 0 External reflector ( 0-50 W) RD 4 External reflector ( W) Metal cable glands see page COOPER CROUSE-HINDS GMBH

53 I Ex-Pendant light fitting I Dimensions drawing NVMV NVMV NVMV 4 Ø Ø Thread /4 BSP Pole mounting 5 5 Ceiling mounting Wall mounting 0 4 Ø54 0 4, Ø 8 4, , NVMV Pole mounting Thread /4 BSP NVMV Ceiling mounting NVMV Wall mounting 8 Polar 0 curve NVMV 0-50 W 0 (without external reflector) Polar 0 curve NVMV 0-50 W 0 (with external reflector) Polar 0 curve NVMV W0 (without external reflector) C 0 C l/cd/klm Polar 0 curve NVMV W0 (with external reflector) C 0 C l/cd/klm C l/cd/klm 0 0 C l/cd/klm Dimensions in mm COOPER CROUSE-HINDS GMBH 4.5

54 E X - F L O O D L I G H T NFMV and NSSFMV for high pressure discharge lamps Metal version for Zone / The floodlights NFMV and NSSFMV in accordance to the ATEX-Directive 4//EG. They have been built and tested according to the European Standard for Gas-Ex-Areas of Zone classification as well as for use in Dust-Ex-Areas of Zone. The light fitting series NFMV and NSSFMV for lamps with a rating of 50 W up to 400 W and have a high quality built-in reflector. The enclosure of the NFMV is made of light alloy with epoxy powder coating. The NSSFMV has a stainless steel enclosure. The transparent part consists of a temperature stable, impact resistant glass. The modular architecture allows for a quick and cost-effective installation of the light fittings. Apart from the direct mounting per swivel bracket there is also a pole version available. A particularly durable sealing system for use under extreme climatic conditions brings additional reliability. The restricted breathing version allows a high illumination combined with a high temperature classification. Rotate und swivel light fitting housing, also for pole mounting Ideal for illumination of large areas and selective individual objects Degree of protection IP66 High corrosion resistance Restricted breathing version For environmental temperatures up to +55 C 4.54

55 I Ex-Floodlight I Technical data NFMV NFMV Marking to 4//EC II G Ex nr II T ) II Ex td A IP66 T ) Type Examination Certificate PTB 0 ATEX 000 Permissable ambient temperature 0 C to +55 C ) Rated voltage 40 V (other voltage on request) Frequency 50 Hz (other frequencies on request) Power factor cos > 0. Connecting terminals L, N and PE; x 4 mm Insulation class I Lamp cap E 40 acc. IEC 8 Light efficiency in operation 45 % Degree of protection accd. EN 5 IP66 Cable glands/gland plates/enclosure drilling x M0 x.5; plugged Dimensions (L x W x H) 6 x 40 x 5 mm Weight ) Enclosure material light alloy with epoxy powder coating Enclosure colour grey Protective cover/protective bowl borosilicate glass ) see table Ordering details Type Lamps Rated luminous Ta Temperature Max. surface Weightt Order No. HSE HIE flux ) class temperature (approx. kg) NFMV... HSE 50 W 50 W 4000 lm 55 C T4 5 C 5.5 NOR HSE 50 W 50 W 5000 lm 50 C T 50 C 6. NOR HSE 400 W 400 W 4000 lm 45 C T C 8.6 NOR HIE 50 W 50 W 000 lm 50 C T 50 C 6. NOR HIE 400 W 400 W 0000 lm 45 C T C 8.6 NOR ) depends on used lamps Lamps and fixing accessories are not included Accessories 8 NFMV... Type Qty. Order No. Slipfitter adapter for pole mounting Metal cable glands see page COOPER CROUSE-HINDS GMBH 4.55

56 I Ex-Floodlight I NFMV Dimensions drawing Ø / - UNC 54 M0 ISO M0x.5 Ø NFMV Swivel bracket - Slip fitter adaptor Polar 0 curve 0 NFMV 0 Dimensions in mm + I: C 0 C l/cd/klm 4.56 COOPER CROUSE-HINDS GMBH

57 I Ex-Floodlight I Technical data NSSFMV NSSFMV Stainless Steel Version Marking to 4//EC II G Ex nr II T/T4 II D Ex td A IP66 T ) Declaration of conformity PTB 0 ATEX 00 Permissable ambient temperature 0 C to max. +55 C Rated voltage 0 V ) Frequency 50 Hz ) Power factor cos > 0. Connecting terminals L, N and PE; x.5 mm Insulation class I Lamp cap E 40 acc. IEC 8 Light efficiency in operation 68 % Degree of protection accd. EN 5 IP66 Cable glands/gland plates/enclosure drilling x M5 x.5, plugged ) Dimensions (L x W x H) 56 x 5 x 5.5 mm Weight ) Type of mounting mounting bracket, stainless steel 6 Enclosure material stainless steel 6 Enclosure colour natural Protective cover/protective bowl borosilicate glass ) see table ) other voltages, frequencies and cable glands on request Ordering details Type Lamps Rated luminous TA Temp. Max. surface Weight Order No. HSE HIE flux ) class temperature (approx. kg) NSSFMV SY50 50 W 4000 lm +40 C/+55 C T4 0 C 6. CCL00005 SY50 50 W 5000 lm +50 C T 80 C.5 CCL000 SY50 50 W 000 lm +50 C T 80 C.5 CCL000 SY W 4000 lm T 5 C 8.6 on request SY W 0000 lm T 5 C 8.6 on request ) depend on oused lamps 8 4) at ta max. +40 C Lamps and fixing accessories are not included Accessories NSSFMV Type Order No. Slipfitter adapter Metal cable glands see page COOPER CROUSE-HINDS GMBH 4.5

58 I Ex-Floodlight I NSSFMV Dimensions drawing Polar curve Ø / - UNC M0 ISO NSSFMV Polar 0 curve 0 NSSFMV C 0 C l/cd/klm Dimensions in mm I: Ø. mounting holes 4.58 COOPER CROUSE-HINDS GMBH

59 COOPER CROUSE-HINDS GMBH 4.5

60 A C C E S S O R I E S Fittings and Ex-Floodlights Lamps for Ex-Pendant Light Fittings and Ex-Floodlights Lamps for Use in Ex-Pendant Light Fittings and Floodlights Lamps for Ex-Pendant Light Fittings and Floodlights are normally not part of the delivery. The lamps are specified by IEC Standards and described by different Lamp Designation Systems. In Europe a standardized system was developed and introduced by the German ZVEI. This system (LBS) allows easily to name a lamp independent from the different manufacturers. In the following table all lamps used in the Ex-pendant light fittings and floodlight are shown with the relevant short description and LBS-name. Spare Parts As well as the above, there is also a large amount of spare parts available for maintenance and repair work. If required, please contact us, you will find that we will be more than pleased to help you. We must point your attention to the fact that repair work done on explosive-protected products must be carried out with original spare parts only! If this is not the case and third-party parts are used, the Certification and Approval for the product will be forfitted and a possible reduction of the explosion-protection may be achieved. Repair Service Of course Cooper Crouse-Hinds GmbH upholds its own Repair Department where customer repairs are carried out. Our qualified and schooled personnel carry out repairs and overhauling using original spare parts, quickly and efficiently. This service also includes the end quality testing needed for explosion protected products. With this service you have an assured safety as do all overhauled Ex-Lamps and products by Cooper Crouse-Hinds GmbH. 4.

61 I Lamps I Accessories Lamps for pendant light fittings and floodlights For fitting Lamp type Lamp Power Luminous flux 0) Order No. cap approx. lm AB 05 Ex e Incandescent IGA E W 0 lm on request AB 05 Ex d HSE 5) E 0 W 50 lm AB 05 nr Incandescent IGA E W/00 W 0/ lm on request AB 05 nr TC-DSE 5 W E 5 W 00 lm on request AB 05 nr TC-DSE 0 W E 0 W 00 lm on request AB 05 nr HSE 5) E 0 W 50 lm AB 80 Incandescent IGA E W/00 W 0/ lm on request AB 50/SPG N Incandescent IGA E W/00 W 0/ lm on request AB 80 TC-DSE W E W 6 lm on request AB 5 TC-DSE 5 W E 5 W 00 lm on request AB 5 TC-DSE 0 W E 0 W 00 lm on request EVI AB 5 Incandescent IGA 65 E 50 W 00 lm on request EVI / AB 5 Incandescent IGA 80 E 00 W 00 lm on request EVI Incandescent IGA 0 E W 5000 lm on request EVI Incandescent IGA 0 E W 8400 lm on request AB 5 Halogene lamp IQT E 5 W 00 lm on request AB 5 Halogene lamp IQT E 50 W 500 lm on request AB 5 HME-SB ) E 00 W 00 lm on request EVI HME-SB ) E W 00 lm on request EVI HME-SB ) E W 50 lm on request EVI HME 4) E 80 W 800 lm on request EVI HME 4) E 5 W 0 lm on request EVI HME 4) E W 000 lm CGS 0 P00 AB 5 HSE 5) E 50 W 400 lm on request EVI HSE 5) E 0 W 50 lm EVI HSE 5) E W 4000 lm EVI HSE 5) E W 5000 lm CGS 80 P00 EVI HIE 6) E W 000 lm EVM HME 4) E 5 W 0 lm on request EVM HME 4) E W 000 lm CGS 0 P00 EVS HSE 5) E 0 W 50 lm EVS HSE 5) E W 4000 lm EVS HSE 5) E W 5000 lm CGS 80 P00 EVH HIE 6) E W 000 lm EVQ 55 Master QL )8) 55 W 500 lm on request EVQ 85 Master QL )8) 85 W 00 lm on request ) HME-SB = mixed light high pressure mercury vapour lamp 4) HME = high pressure mercury vapour lamp ) HSE/HST = high pressure sodium vapour lamp 6) HIE/HIT = High-pressure metal halide lamp ) Trade mark of Philips company 8) Single components of this system as spare parts available Lamp QL (55 W/85 W) Power Coupler QL (55 W/85 W) HF-generator QL (55 W/85 W) ) QT = halogene lamp with protective bulb 0) Diviations of lamp rated luminous flux possible depending to used product COOPER CROUSE-HINDS GMBH 4.6

62 I Lamps I Accessories Lamps for pendant light fittings and floodlights For fitting Lamp type Lamp Power Luminous flux 0) Order No. cap approx. lm FZD HIT 6) E W 000 lm CGS 0 P00 FZD HIT 6) E W 5000 lm CGS 0 P008 FZD HST 5) E W 000 lm FZD HST 5) E W lm dhls 85 HME 4) E W 000 lm CGS 0 P00 dhls 85 HME 4) E W 000 lm CGS 0 P0 dhls 85 HSE 5) E W 5000 lm CGS 80 P00 dhls 85 HSE 5) E W 4000 lm CGS 800 P00 dtls 85 HIT-DE 6) Fc 50 W 000 lm CGS 0 P00 dtls 85 HST-DE 5) Fc 50 W 5000 lm CGS 8500 P00 dtls 85 HST-DE 5) RXs 0 W 6800 lm GHG 6 P000 PX HIT 6) E 50 W 4000 lm on request PX HIT 6) E W 0000 lm CGS 0 P00 PX HIT 6) E W 5000 lm CGS 0 P008 PX HST 5) E W 000 lm on request PX HST 5) E W 000 lm PX HST 5) E W lm PX HST 5) E 40 0 W 0000 lm on request PX HME-SB ) E W 4000 lm on request PX IQT ) E W 0000 lm on request KFL Halogene reflector lamp type Sylvania- GZ0 0 V/50 W 680 lm NOR NVMV Champ 0-50 W HSE 5) E 0 W 50 lm NVMV Champ 0-50 W HSE 5) E W 4000 lm NVMV Champ 0-50 W HME 4) E 5 W 0 lm on request NVMV Champ 0-50 W HIE 6) E 0 W 500 lm NVMV Champ 0-50 W HIE 6) E 50 W 000 lm on request NVMV Champ W HSE 5) E W 5000 lm CGS 80 P00 NVMV Champ W HSE 5) E W 4000 lm CGS 800 P00 NVMV Champ W HME 4) E W 000 lm CGS 0 P00 NVMV Champ W HIE 6) E W 000 lm NVMV Champ W HIE 6) E W 0000 lm NFMV HSE 5) E W 4000 lm NFMV HSE 5) E W 5000 lm CGS 80 P00 NFMV HSE 5) E W 4000 lm CGS 800 P00 NFMV HME 4) E W 000 lm CGS 0 P00 NFMV HME 4) E W 000 lm CGS 0 P0 NFMV HIE 6) E W 000 lm NFMV HIE 6) E W 0000 lm ) HME-SB = mixed light high pressure mercury vapour lamp 4) HME = high pressure mercury vapour lamp 5) HSE/HST = high pressure sodium vapour lamp 6) HIE/HIT = High-pressure metal halide lamp ) Trade mark of Philips company 8) Single components of this system as spare parts available Lamp QL (55 W/85 W) Power Coupler QL (55 W/85 W) HF-generator QL (55 W/85 W) ) IQT = halogene lamp with protective bulb 0) Diviations of lamp rated luminous flux possible depending to used product 4.6 COOPER CROUSE-HINDS GMBH

63 EX-AUDIO/VISUAL-SIGNALLING EQUIPMENT SIGNALLING IN HAZARDOUS AREAS EX-MANUAL CALL POINTS EX-STATUS LAMPS EX-BEACONS AND STROBES EX-SOUNDERS AND HORNS EX-SPEAKERS EX-HEAT DETECTORS 5.68

64 I Signalling in Hazardous-Areas I Visual and Audible Signalling Devices as tough as your environment. Why Cooper Products? The broadest line of harsh and hazardous signalling, alarm and communication products available in both IEC and NEC designs and certifications. A new line of hazardous area call points (fire alarm or emergency notification devices) provides you a unique product offering unequalled by any other manufacturer of hazardous location signalling products. Worldwide listings with UL, cul, ATEX, GOST, CSA and CQST (Chinese) approvals provide customer solutions that the competition can t match. Superior enclosure materials providing unmatched ingress protection and corrosion resistance from the harshest conditions. A unique signalling product offering integral visual and audible signalling capability pre-wired for simultaneous output activation. A new line of heat detectors for early indication of potential processing problems. Applications Include: Petrochemical Facilities Manufacturing Areas Waste Water Treatment Food Processing Facilities Paper and Pulp Operations Pharmaceutical Manufacturing 5. COOPER CROUSE-HINDS GMBH

65 ALARM, SIGNAL AND CONTROLL EQUIPMENT FOR HAZARDOUS AREAS A powerful Member of the Cooper Group: MEDC Ltd. Designers and manufacturers of Alarm, Signal and Control Equipment since 5, MEDC have developed a range of products specifically designed for use in areas where harsh environmental conditions prevail and where there is a risk of explosion due to the presence of flammable atmospheres. MEDC are renowned throughout the world for their exacting quality standards and reliability as a leading manufacturer of Explosion Proof Equipment. 4 MEDC has also recently developed a range of equipment for use in industrial, marine, commercial and leisure applications. MEDC specialises in custom finished products to specific requirements. The full product range totals over 00 items, all of which are appro - priately certified to internationally recognised standards, eg ATEX/CENELEC, UL, CSA, FM, SGS, GOST R & K, SAA, Chinese (CQST), PTB. 5 6 MEDC holds the International Quality Assurance Standard, ISO00, which covers all company activities from design and development, to manufacture, sales and after sales service. In addition to the above certification, MEDC products have approval from The Ministry of Defence, British Gas and UK Coal Mining. International Certifications ATEX/CENELEC, UL, CSA, FM, GOST R & K, SAA, Chinese (CQST), PTB Highest degree of protection IP66/IP6 8 For more detailed information please visit the web-side: or contact your local MEDC representative. 0 5.

66 E X - M A N U A L C A L L P O I N T S Explosion protected units for Zone 0,,,, Class I and Div & The BG manual fire alarm call point is designed in accordance with the latest draft European Call Point Standard (EN54-). Weatherproof to IP66 and IP6 and available certified intrinsically safe, simple apparatus or uncertified, the units are manufactured from glass reinforced polyester (GRP) which provides a robust, corrosion free construction and ensures effective and reliable operation in harsh industrial and offshore environments. Units are supplied in self coloured GRP or painted to customer specification. The BG 'Burning House' duty label is provided as standard, other duty and tag labels may be supplied to customer specification. Zone 0,,, and Zone use Chinese (CQST) certified Designed in accordance with EN54- IP66 and IP6 Certified temperature -55 C to +55 C Corrosion free GRP Optional in line/end of line resistors/diodes Optional LED indicator Optional lift flap Optional flush installation Optional glass substitute element Key operated test facility Various body colours available 5.4

67 I Ex-Manual alarm call point I Technical data BG E/I Type BG E/I EC-Type Examination Certificate BG E BAS 0 ATEX 05 X BG I Baseefa 0 ATEX 0084 X Marking to 4//EC BG E II G/D Ex edm IIC T4 T5 C II G/D Ex ed IIC T6 T85 C BG I II G/D Ex ia IIC T4 T5 C Enclosure material U.V. resistant glass-fibre reinforced polyester Finish Self coloured red Optional indicator A red high intensity LED can be fitted for alarm indication Rated voltage BG E up to 50 V (switch only)/up to 4 V (resist. + switch) BG I up to 8 V (IS) Rated current only BG E DC 0-0 V: 5 A (resistive)/ A (inductive) DC 0-50 V: A AC 0-50 V: 5 A Circuits Switch only / End of Line Resistor/Diode In Line Resistor/Diode / In Line & End of Line Resistor/Diode Entries x M0 bottom Weight. kg Rated terminal cross section 6 x.5 mm Protection category to EN 5 IP66/IP6 Permissible ambient temperature -0 C to +50 C (BG E) / -40 C to +50 C (BG I) Resistor values 40 Ω min./ kω max. (DC and IS only) Ordering details Catalogue No. Certification Description Ordering Code BGEDCN ATEX Ex II GD Explosion protected, Zone 0, &, DC, x M0 bottom entries, PX single break glass switch latching, red finish BGINNN ATEX Ex II GD Explosion protected, Zone 0, &, DC, x M0 bottom entries, PX single break glass switch latching, red finish 8 Ordering options* Unit Type Model Code Wiring Diagram Code Lift Flap Code Finish Code BG BGW AC or DC BGWNN Switch only Fitted F Natual red N BGI Up to 8 V (I.S.) BGINN End of line resistor Not fitted N Red Painted R BGE DC BGEDC In line resistor BGE AC BGEAC In line and end of line resistor 4 Diode (specify location & value) 5 * For more options see or contact your local representative Dimension drawing 0 0 FIRE BG E/I Dimensions in mm COOPER CROUSE-HINDS GMBH 5.5

68 I BGI, PBI, BGE, PBE, BGUL, PBUL I PB.../BG... Technical data Type BGE, PBE, BGI, PBI, BGUL, PBUL Enclosure material Finish Optional indicator Rated current only BG/PB E Circuits Entries Weight Rated terminal cross section Protection category to EN 5 Resistor values anti static U.V. resistant glass reinforced polyester Red epoxy painted finish as standard A red high intensity LED can be fitted to indicate operation on versions up to 4 V and all IS versions DC 0-0 V: 5 A (resistive)/ A (inductive) DC 0-50 V: A / AC 0-50 V: 5 A single changeover or double changeover Up to 4 entries, M6 or M0 top and bottom / / NPT. kg (varies with model & entries) x.5 mm / x.5 mm optional u to V only IP66/IP6 Various configurations available on versions up to 4 V and all IS versions (min. value 40 Ω) Type BGE, PBE EC-Type Examination Certificate BAS 0 ATEX 05 X Marking to 4//EC II G/D Ex edm IIC T4 T5 C (switch only) II G/D Ex ed IIC T6 T85 C (other versions) GOST R Certification Ex edm IIC T6 (switch only) / Ex edm IIC T4 (other version) Russian Fire Approved (VNIIPO) Chinese Certification CQST Ex ed IIC T6 (switch only) / CQST Ex edm IIC T4 (other versions) Rated voltage up to 50 V Permissible ambient temperature -0 C to +50 C Type BGI, PBI EC-Type Examination Certificate BAS 0 ATEX 0084 X Marking to 4//EC II G/D Ex ia IIC T4 T5 C CSA Certification to C. (PBI only) Nos. 0-M, 0.4-M, 5, 0-M, 4, 4-M8, 5-M8, 5-, Enclosure Type 4. T4A Class I Groups A, B, C & D Cert. No. 0 GOST R Certification (PBI & BGI) Ex ia IIC Russian Fire Approved (VNIIPO) GOST K Certification (PBI only) Ex ia IIC T4 Chinese Certification (PBI & BGI) CQST - Ex ia IIC T4 Rated voltage up to 8 V (IS) Permissible ambient temperature ATEX -40 C to +0 C (PBI) Z ATEX -40 C to +50 C (BGI) CSA -50 C to +40 C (PBI only) Type BGUL, PBUL UL-Listed Class I, Div, Groups A-D Listing No. E866 Rated voltage up to 40 V Permissible ambient temperature -5 C to +55 C 5.6 COOPER CROUSE-HINDS GMBH

69 I BGI, PBI, BGE, PBE, BGUL, PBUL I Ordering details PB.../BG... Catalogue No. Certification Description Ordering Code BGEB4B6BDSN6R ATEX Ex II GD Explosion protected Ex II GD, Exed, IIC, T6, Zone &, DC, PX x M0 bottom entries, single break glass switch latching, red finish BGIB4B6BDSN6R ATEX Ex II GD Explosion protected, Zone 0, &, DC, x M0 bottom entries, PX single break glass switch latching, single switch, red finish BGUL4C6CDSN6R UL Listed, Class I, Explosion protected, x / NPT bottom entries, single break PX 8 Div, Groups A, B, glass switch latching, painted red GRP finish C, D, Zone Ordering options* Unit Certification Code Entries Code Labels Code Switches Code Features Code Terminals Code Finish Code Type BG ATEX Exe EB 6 mm A ) None 0 Single None N x.5 mm Red PB ATEX Exi IB 0 mm B ) Glass label change- LED A x.5 mm (Standard) R CSA Exi / NPT C ) Glass label over S ) Lift flap Natural (PBI only) IC Glass label Double (BG only) B Black N UL Class I, Div UL Duty label change- Resistor Series C 4) Blue B GOST R ) Exi IG reqd. 4 over D ) Resistor EOL D 4) Yellow Y GOST R ) Exe EG Tag label 5 Diode E Grey G GOST K Exi Earth Continuity F Yellow/Black (PBI only) IK Turn & Push Stripes X Chinese Exe EQ (PB only) T Other Chinese Exi IQ Self reset specify S (PB only) M Resistor Series & EOL S 4) Plastic element replaces Break glass P * For more options see or contact your local representative ) VNIIPO approved as standard. ) Prefix entry size (see diagram above) with entry position code e.g. A, A. UL & CSA versions only available with / NPT entries. ) Prefix with voltage A for A.C. D for D.C. except for BGI. 4) Specify values Not available for UL/CSA Dimension drawing 6 0 FIRE 6 6 Break glass unit Nameplate 0 Duty Label Lift Flap Face B Pushbutton unit Face A 4 68 Tag Label COOPER CROUSE-HINDS GMBH 5. Dimensions in mm 0

70 I Ex-Break glass/pb call point I SM8 PB SM8 BG Technical data SM8 BG SM8 PB EC-Type Examination Certificate Ex i Baseefa 0 ATEX 05 X Ex d Baseefa 0 ATEX 005 Marking to 4//EC Ex i II G Ex ia IIC T4 Ex d II G/D Ex d IIC T5/T6 UL listed Class I, Div Groups C & D (PBL only) Listing No. 866 CSA Certification Class I Groups A-D (I.S. version only PBI) Class I, Div &, Group D (Ex-d PB, BG only) GOST R Certification Ex ib IIC T4 / Ex d IIC T4 / Russian Fire Approved (VNIIPO) GOST K Certification Ex ib IIC T4 Chinese Certification CQST Ex ia IIC T4 / Ex d IIC T5/T6 Enclosure material Grade 6 ANC4B Stainless Steel or LM 5 TF Marine Grade Alloy Finish Epoxy paint finish as standard or to customer s specification Optional indicator A red high intensity LED can be fitted for alarm indication Rated voltage Ex d: 4 V AC/DC / Ex i: 8 V Rated current A Switches pole c/o wired to terminals, optional up to 4 pole Entries up to 4 x 0 mm or 5 mm ISO / up to 4 x / or /4 NPT Weight.8 kg (steel) /.5 kg (alloy) Rated terminal cross section 5 mm Protection category to EN 5 IP66/IP6/IP68 (SM8 PB) Insulation class I Permissible ambient temperature Ex d/ex-i* 55 C to +0 C LED version* 0 C to +55 C UL 55 C to +0 C UL LED version 0 C to +55 C CSA Exd 50 C to +55 C CSA Exe 50 C to +40 C Resistor values 40 Ω minimum (DC and IS only) * inlcudes ATEX, GOST and Chinese 5.8 COOPER CROUSE-HINDS GMBH

71 I Ex-Manual call points I Ordering details SM8 BG SM8 PB Catalogue No. Certification Description Ordering Code SM8BGLADBNNR ATEX Ex II GD Break glass call point, Ex II GD, Exd IIC T6, IP66 & 6, PX x M0 bottom entries, duty label, Fire Breakglass, alloy material, red finish SM8PBLAULTBNNR UL, CSA, Class I, Explosion protected, x / NPT entries, duty label PX 00 Div, Groups C & D, Fire-Press Here, single push button switch-latching, Zone marine grade alloy, red finish Ordering options* Unit Model Code Material Code Cert. Code Entries Code Duty Code Tag Code Features Code Finish Code Type label label SM 8 Breakglass SS 6 S Ex ia IIC T4 I 0 mm Fire-Break- required Y Not Red R unit, latching BGL Alloy A Ex d IIC T6 D 5 mm glass not required N Blue B Lift flap UL UL / NPT Push- required N LED A Yellow Y Breakglass CSA Exd DC /4 NPT 4 Button Resistor Yellow/ latching LBGL CSA Exi IC Top T ) Button Series G Black Push Button GOST K Exi IK Bottom B ) Fire-push Resistor Stripes X Latching GOST R Exi IG RHS R ) Button 4 EOL H Special key reset PBL GOST R Exd DG LHS L ) Other O Diode D ) Finish S Push Button Chinese Exi IQ None N pole c/o self reset PBM Chinese Exd DQ switch T 4 pole c/o switch F ) prefix position with size code (T, B, R, L) e.g. T B = 0 mm Top and Bottom ) Specify values * For more options see or contact your local representative Dimension drawing holes Ø.5 05 (A)8 (B)05 (A) Pushbutton version (B) Breakglass version 0 COOPER CROUSE-HINDS GMBH 5. Dimensions in mm

72 I Ex-Break glass call point I BG Technical data BG EC-Type Examination Certificate BAS 00 ATEX 06X Marking to 4//EC II G Ex ia IIC T4 Chinese Certification CQST Ex ia IIC T4 Enclosure material UV resistant glass reinforced polyester Finish Natural Red GRP or painted* Optional indicator A red high intensity LED can be fitted to indicate operation on versions up to 4 V and all IS versions Rated voltage up to 8 V (IS) Entries x M0 bottom Weight 0.5 kg Rated terminal cross section 6 x 4.0 mm Protection category to EN 5 IP66/IP6 Permissible ambient temperature 55 C to +55 C (BGE) Resistor values 40 Ω min. 5.0 COOPER CROUSE-HINDS GMBH

73 I Ex-Break glass call point I Ordering details BG Catalogue No. Certification Description Ordering Code BGINBN ATEX Ex II G Explosion protected, Zone 0, &, DC, standard models are PX surface mount version, have x M0 bottom entries, single break glass switch latching, duty label Burning House, red GRP finish 4 Ordering options* Model Certification Code Label type ) Code Features Code Entries Code Body colour Code BGI Ex ia I Fire break glass None N x 0 mm Natural red* N CQST Q Press here Resistor series S (bottom) B ) Red paint R Break glass Resistor EOL E x 0 mm Blue B Press here Diode D (top) T ) Green G Special Polycarbonat lift flap F White W European Stainless steel lift flap C Yellow Y Standard (draft) LED L Special S 4 Double changeover T Duty label (special) Flush Mounting (weatherproof only) M (Burning house Plastic element as standard) 5 (replaces break glass) P Tag label 6 ) Specify wording on, 5 & 6 ) For blanking plugs add P to code. * For more options see or contact your local representative 5 6 Dimension drawing ,5 80 8,5 44,5 46,5 Surface mount unit Panel/flush mount unit 0 COOPER CROUSE-HINDS GMBH 5. Dimensions in mm

74 E X - S T A T U S L A M P S Explosion protected units for Zone 0,, and Theses ranges of versatile status lights have been designed to suit various offshore and onshore applications. Available as LED, xenon, filament and fluorescent beacons.the SM8 SL range is manufac tured in marine grade alloy and the XB/XB SL in corrosion-free GRP to provide a wide range of status lights to suit clients' requirements.all units can be supplied as,,, 4 or 5 way. A long life, high intensity, LED version is now available. Zone and Zone use BASEEFA certified UL listed for USA and Canada Class I, Div. &, Groups C & D. Class I, Zone, AExd IIB T6 CSA certified GOST R & K certified Chinese (CQST) certified IP66 & 6 Certified temperature 55 C to +0 C LED, xenon, fluorescent, filament Marine grade alloy or GRP Close-coupled and pre-wired to customer s requirements 5.

75 I Ex-Status lamps I Technical data XB SL XB SL Range EC-Type Examination Certificate BAS ATEX 5X Marking to 4//EC II G/D Ex d IIB T* UL Listed for USA and Canada Class I, Div, Groups C & D / Class I, Zones & Listing No. E884 Chinese Certified Ex d IIB T5/T6 Enclosure material UV stable, glass reinforced polyester Finish Natural Black or Epoxy paint to customers specification Lens Glass Lamp types Xenon 5 joules maximum Fluorescent 0 W or 5 W Filament 0 W maximum Rated voltage Xenon 4 V DC/0, 40 V AC Filament Voltages 4, 48 V DC/0, 0, 40, 54 V AC Fluorescent Voltages 4 V DC, 40 V AC Lamp Colours Red, amber, yellow, green, blue or clear Light module to 5 ways Entries x M0 Rated terminal cross section max..5 mm Protection category to EN 5 IP66/IP6 Insulation class I Permissible ambient temperature -55 C to +0 C * see table below Ordering details Catalogue No. Certification Description Ordering Code XBSL UL Listed, Class I, Explosion protected, stack, one /" NPT entry on bottom, PX Div, Groups C & D 4V DC, green incandescent on top, yellow xenon flashing in middle, red xenon flashing on bottom, no lens guards, red finish Temperature classifications Type... Lamp Ambient temperature Temperature Classification (G/D) at Tamb. 55 C 0 C +40 C +55 C +0 C XBSL Filament X X T6/T 85 C T5/T 00 C XBSL Fluorescent X T5/T 00 C T4/T 5 C XBSL Xenon X X T6/T 85 C T5/T 00 C T4/T 5 C * For more options see or contact your local representative Dimension drawing Dimensions in mm COOPER CROUSE-HINDS GMBH 5.

76 I Ex-Status lamps I SM8 SL Technical data SM8 SL EC-Type Examination Certificate Baseefa 0 ATEX 0X Marking to 4//EC II G/D Ex d IIC T* UL Listed Class I, Div, Groups C & D Class I, Zone, AExd IIB T6 Listing No. E884 CSA Certified Class I, Div GOST R & K Certified Zones & IP66 & 6 NEMA 4 x 6 Enclosure material LM 5 TF Marine Grade Alloy Finish Epoxy paint finish as standard or to customer s specification Lens Glass Lamp types Xenon 5 joules maximum Fluorescent 0 W or 5 W Filament 40 W maximum Rated voltage Xenon 4, 48 V DC/0, 0, 40, 54 V AC Filament Voltages, 4, 48 V DC/0, 0, 40, 54 V AC Fluorescent Voltages, 4, 48 V, 0, 40, 54 V AC Lamp Colours Red, amber, yellow, green, blue or clear Light module to 5 ways Entries Up to x M0 or M5 / x / or /4 NPT Rated terminal cross section max..5 mm Protection category to EN 5 IP66/IP6 Permissible ambient temperature LED and fluorescent -5 C to +55 C* Xenon & filament -55 C to +0 C * see table below Temperature classifications Type Lamp Voltage Watts Temperature Classification (G/D) at Tamb. -5 C to +... C +40 C +55 C +0 C SM 8 SL Filament 40 AC 48 T4/T 5 C T/T 00 C SM 8 SL Fluorescent 54 AC 40 AC 0 T5/T 00 C T4/T 5 C 0/0 AC T6/T 85 C T5/T 00 C, 4, 48 DC 5 T6/T 85 C SM 8 SL Xenon 0, 40, 54 AC, 4, 0, 48 DC T6/T 85 C T4/T 5 C T4/T 5 C 5.4 COOPER CROUSE-HINDS GMBH

77 I Ex-Status lamps I Ordering details SM8 SL Catalogue No. Certification Description Ordering Code SM8SL UL, cul Listed, Xenon status lamp, two stack 5 joule beacons interconnected PX 0055 Class I, Div, on a painted red stainless steel baseplate, one red and Groups C & D one green lens color, one /" NPT entry in the bottom unit for customer connection SM8SL UL, cul Listed, Incandescent status lamp, two stack 40 watt beacons PX 0056 Class I, Div, interconnected on a painted red stainless steel baseplate, Groups C & D one red and one green lens color, one /" NPT entry in the bottom unit for customer connection SM8SL UL, cul Listed, Fluorescent status lamp, two stack 5 watt beacons interconnected PX 005 Class I, Div, on a painted red stainless steel baseplate, one red and Groups C & D one green lens color, one /" NPT entry in the bottom unit for customer connection SM8SL UL, cul Listed, Xenon status lamp, two stack 5 joule beacons interconnected PX 0058 Class I, Div, on a painted red stainless steel baseplate, one red and Groups C & D one green lens color, one /" NPT entry in the bottom unit for customer connection SM8SL UL, cul Listed, Explosion protected, stack, one /" NPT entry on bottom, PX 004 Class I, Div, no lens guards, xenon strobe with red, green, and clear lens Groups C & D SM8SL UL, cul Listed, Xenon status lamp, three stack 5 joule beacons interconnected PX 005 Class I, Div, on a painted red stainless steel baseplate, one red, one amber Groups C & D and one green lens color, one /" NPT entry in the bottom unit for customer connection SM8SL UL, cul Listed, Incandescent status lamp, three stack 40 watt beacons PX 00 Class I, Div, interconnected on a painted red stainless steel baseplate, Groups C & D one red, one amber and one green lens color, one /" NPT entry in the bottom unit for customer connection SM8SL UL, cul Listed, Fluorescent status lamp, three stack 5 watt beacons PX 006 Class I, Div, interconnected on a painted red stainless steel baseplate, Groups C & D one red, one amber and one green lens color, one /" NPT entry in the bottom unit for customer connection SM8SL UL, cul Listed, Xenon status lamp, three stack 5 joule beacons interconnected PX 006 Class I, Div, on a painted red stainless steel baseplate, one red, one amber Groups C & D and one green lens color, one /" NPT entry in the bottom unit for customer connection SM8SL UL, cul Listed, Fluorescent status lamp, three stack 5 watt beacons PX 006 Class I, Div, interconnected on a painted red stainless steel baseplate, Groups C & D one red, one amber and one green lens color, one /" NPT entry in the bottom unit for customer connection * For more options see or contact your local representative Dimension drawing Dimensions in mm COOPER CROUSE-HINDS GMBH 5.5

78 I Ex-Status lamps I SL 5 Technical data SL 5 EC-Type Examination Certificate BAS 0 ATEX 08X Marking to 4//EC II G Ex e* Chinese (CQST) Exem II T4, LED Exe II T, Filament Exem II T4, Xenon Enclosure material UV stable, glass reinforced polyester Finish Body natural black or painted to client specifications Lens Polycarbonate Lamp types Xenon joules maximum / Fluorescent x 5 W Filament 400 W maximum Rated voltage Xenon 4, 48 V DC Filament Voltages, 4, 48 V DC/0, 0, 40, 54, V AC LED, 4 V AC Lamp Colours Filament and Xenon Red, amber, yellow, green, blue or clear LED Red, amber or green Light module to 5 ways Entries max. x M6 or M0/max. x M0/M Rated terminal cross section max. x 4 mm /6 x.5 mm Protection category to EN 5 IP66/IP6 Insulation class I Permissible ambient temperature LED -40 C to +45 C* Xenon & filament -40 C to +55 C * see table temperature classifications page COOPER CROUSE-HINDS GMBH

79 I Ex-Status lamps I Temperature classifications SL 5 Type Lamp Voltage Watts Temperature Classification (G/D) at Tamb. -5 C to +... C +40 C +55 C +0 C SL 5 Filament 40 AC 48 T4/T 5 C T/T 00 C SL 5 Fluorescent 54 AC 40 AC 0 T5/T 00 C T4/T 5 C 0/0 AC T6/T 85 C T5/T 00 C, 4, 48 DC 5 T6/T 85 C SL 5 Xenon 4, 48 DC T6/T 85 C T4/T 5 C T4/T 5 C SL 5 LED 4 LED blue 4, 48 DC 5, 6 T6/T 85 C T4/T 5 C Ordering options* 4 5 Unit Type Code Lamp Type Position ) Code Voltage Code Cable Code Duty/Tag Code Finish Code V W X Y V Z entries label SL5 Exe(m) E Filament V DC 0 M6 A ) Duty label D ) Natural Black N Chinese Xenon 4 V DC 04 M0 B ) Tag T ) Special S 4) (CQST) Q LED 48 V DC 048 M5 C ) None N ) LED flashing 4 0 V DC 0 M D ) Suffixed by colour required 0 V DC 0 Red R 40 V AC 40 Amber A 54 V AC 54 Yellow Y V AC Blue B Green G Clear C ) Select lamp type and lens colour for each position e.g. V W X Y Z R G Y ) Prefix with cable entry position ) Specify wording 4) Please specify * For more options see or contact your local representative Dimension drawing Lamp Position V 0 4 ctrs Top 4 ctrs W X Y Z,5 5 6 Bottom, ,5 44,5,5 Dimensions in mm COOPER CROUSE-HINDS GMBH 5.

80 I Ex-Status lamps I XB SL Technical data XB SL Range EC-Type Examination Certificate BAS ATEX 6 Marking to 4//EC II G Ex d IIB T* UL Listed for USA and Canada Class I, Div, Groups C & D Class I, Zones & AExd IIB T4/T5 Listing No. E884 Enclosure material UV stable, glass reinforced polyester Finish Natural Black or Epoxy paint to customers specification Lens Glass Lamp types Xenon joules maximum Filament W maximum Rated voltage Xenon 4 V DC/0, 40 V AC Filament Voltages 0, 40 V AC Lamp Colours Red, amber, yellow, green, blue or clear Light module to 5 ways Entries x M0 / x / NPT Rated terminal cross section max..5 mm Protection category to EN 5 IP66/IP6 Insulation class I Permissible ambient temperature -55 C to +0 C * see table below 5.8 COOPER CROUSE-HINDS GMBH

81 I Ex-Status lamps I Ordering details XB SL Catalogue No. Certification Description Ordering Code XBSL UL Listed, Class I, 4V DC xenon status lamp, two stack joule beacons PX 4000 Div, Groups C & D interconnected on a painted red stainless steel baseplate, one red and one green lens color, /" NPT entry XBSL UL Listed, Class I, 0V AC, explosion protected, three stack, one /" NPT entries, PX 4000 Div, Groups C & D red xenon flashing on top, amber xenon flashing in middle, clear xenon flashing on bottom; no lens guards, red finish XBSL UL Listed, Class I, 4V DC xenon status lamp, three stack joule beacons PX 4000 Div, Groups C & D interconnected on a painted red stainless steel baseplate, one red, one amber and one green lens color, /" NPT Temperature classifications 4 5 Type... Lamp Ambient temperature Temperature Classification (G/D) at Tamb. 55 C 0 C +40 C +55 C +0 C XBSL Filament X X T5 T4 XBSL Xenon X X T5 T5 T4 * For more options see or contact your local representative 6 Dimension drawing ,5 5,5 0 0 Entry,L 0 Ø 4 Entry,R Dimensions in mm COOPER CROUSE-HINDS GMBH 5.

82 E X - B E A C O N S A N D S T R O B E S Explosion protected units for Zone 0,,,, Class I and Div & These certified beacons have been designed for use in harsh environmental conditions. The stainless steel or marine grade alloy enclosures are suitable for use offshore or onshore, where light weight combined with corrosion resistance and strength is required. The glass reinforced polyester enclosures are suitable for use offshore or onshore, where light weight combined with corrosion resistance is required. Units can be painted to customer specifi cation and fitted with identification labels. LED version available, offering extended lifetimes. Stainless Steel screws and mounting bracket are incorporated ensuring a totally corrosion free unit. Units can be painted to customer specification and supplied with identification labels. IP66 and IP6 Certified Temperature -55 C to +55 C Corrosion Free GRP UL Listed for USA and Canada Hazardous locations: Class I, Div &, Groups C & D. Class I, Zones &, AExd IIB T4/T5. Ordinary locations: Visual-Signal Device Australian (SAA) certified Chinese (CQST) certified NEMA 4x, & 6 Various lens colours Optional lens guard Optional gland plus cable tail Stainless steel mounting bracket on request Replaceable tube 5.0

83 I Ex-5 joule flashing xenon I Technical data XB XB EC-Type Examination Certificate BAS 00 ATEX 0 Marking to 4//EC II G/D Ex d IIC T5/T6 T00 C/T 5 C Enclosure material Corrosion-free GRP Lens material Toughened glass Finish Natural black or painted to customer specification Rated voltage - 48 V DC/0-54 V AC 50/ Hz Power consumption DC V ma / DC 4 V 8 ma / DC 48 V ma AC 0 V ma / AC 40 V 5 ma / AC 54 V 5 ma Flash rate Hz Entries entry, M0 Weight.6 kg Rated terminal cross section x.5 mm Protection category to EN 5 IP66/IP6 Insulation class I Permissible ambient temperature from -55 C to +55 C Ordering details Catalogue No. Certification Description Ordering Code XBD0406RYNCBN ATEX Approved 5 joules, 4 V DC, red lens, lens guard, S/S mounting bracket, Ex II G, Exd, IIC, T5 GRP body, x M0 entry + m cable, flashes/min., no labels PX 805 XBD0406AYNCBN ATEX Approved 5 joules, 4 V DC, amber lens, lens guard, S/S mounting bracket, Ex II G, Exd, IIC, T5 GRP body, x M0 entry + m cable, flashes/min., no labels PX 806 XBD4006RYNCBN ATEX Approved 5 joules, 40 V AC, red lens, lens guard, S/S mounting bracket, Ex II G, Exd, IIC, T5 GRP body, x M0 entry + m cable, flashes/min., no labels PX 80 XBD4006AYNCBN ATEX Approved 5 joules, 40 V AC, amber lens, lens guard, S/S mounting bracket, Ex II G, Exd, IIC, T5 GRP body, x M0 entry + m cable, flashes/min., no labels PX Ordering options* Model Voltage Code Flash Code Lens Code Lens Code Tag/Duty Code Entries/ Code Finish Code rate colour guard label cable tail XBD DC V 0 /min. 06 Red R None N None N x M0 B Natural Black N DC 4 V 04 Blue B Yes Y Yes Y x PG.5 P Red R DC 48 V 048 Green G m cable CB Blue B AC 0 V 0 Yellow Y Yellow Y AC 40 V 40 Amber A Grey G AC 54 V 54 Clear C White W Special finish S * For more options see or contact your local representative 0 Dimension drawing 4, Ø 8 Dimensions in mm COOPER CROUSE-HINDS GMBH 5.

84 I Ex-5 joule flashing xenon I SM 8 SM 8 with exlink Technical data SM 8 EC-Type Examination Certificate Baseefa 0 ATEX 0 Marking to 4//EC II G/D Ex d IIC T4/T6 T85 C/T 5 C CSA Certification to C. Nos. 0, 0.4, 0.5,, 0-M86, 4-M, -M-8 Class I, Div, Group D, Enclosure /4 Cert. No (HXB only) UL Listed for USA & Canada Class I, Div, Groups C & D Class I, Zone (HXB & XBT only) Listing No. E884 GOST R Certification Exd IIC T4 (HXB only) Russian Fire Approved (VNIIPO) GOST K Certification Exd IIC T4 Chinese (CQST) Certification Exd IIC T4/T6 (HXB only) Enclosure material Marine Grade Alloy or Stainless Steel Lens material Glass* Finish Red epoxy painted finish as standard Rated voltage 4 V - 48 V DC/0-54 V AC 50/ Hz Power consumption DC 4 V. W / DC 48 V.6 W tube 5 joule AC 0 V 5 W / AC 0 V W / AC 0 V 5 W AC 40 V W / AC 54 V 5 W Initiation Telephone or relays initiated Entries up to 4 entries, M0 or M5 / up to 4 x / or /4 NPP Rated terminal cross section 6 x.5 mm Protection category to EN 5 IP66/IP6 Insulation class I Permissible ambient temperature ATEX HXB 55 C to +0 C LED 0 C to +40 C XBT (High temp.) 40 C to +85 C CSA Certified 50 C to +40 C UL HXB 55 C to +0 C XBT (High temp.) 40 C to +85 C GOST R HXB 55 C to +55 C * Optional with lens guard Dimension drawing 05,5 0,5 0 (S) (A) 05,5 0,5 Ø 0,5 80 (S) 0 (A) 55 (S) 6 (A) 8 (S) 0 (A) Dimensions in mm 5. COOPER CROUSE-HINDS GMBH

85 I Ex-5 joule flashing xenon I Ordering details SM 8 with exlink SM 8 Catalogue No. Certification Description Ordering Code SM8HXBAB04ANRLNNR ATEX EX II GD 5 joules, 4 V DC, amber lens, x M0 Entries, Cd PX 8006 Ex d IIC SM8HXBAB04RNRLNNR ATEX EX II GD 5 joules, 4 V DC, red lens, x M0 Entries, Cd PX 8005 Ex d IIC SM8HXBAB40ANRLNNR ATEX EX II GD joules, 40 V AC, amber lens, x M0 Entries, Cd PX 8008 Ex d IIC SM8HXBAB40RNRLNNR ATEX EX II GD joules, 40 V AC, red lens, x M0 Entries, Cd PX 800 Ex d IIC SM8LEDAB04RNRLNNR ATEX EX II GD 4 V DC, red lens, x M0 entries, Cd PX 800 SM8HXBAUL04ANRLNNR UL, cul Listed, Standard models are in alloy, red body color, no tag or PX 866 Class I, Div, duty labels, x /" NPT entries, Cd Groups C & D SM8HXBAUL04RNRLNNR UL, cul Listed, Standard models are in alloy, red body color, no tag or PX 866 Class I, Div, duty labels, 4 V DC, red lens, x /" NPT entries, Cd, Groups C & D flashes per minute SM8HXBAUL0ANRLNNR UL, cul Listed, Standard models are in alloy, red body color, no tag or PX 8666 Class I, Div, duty labels, 0 V AC, amber lens, x /" NPT entries, Groups C & D Cd, AExd IIB SM8HXBAUL0RNRLNNR UL, cul Listed, Standard models are in alloy, red body color, no tag or PX 8665 Class I, Div, duty labels, 0 V AC, red lens, x /" NPT entries, Cd, Groups C & D AExd IIB Ordering options* Model Code Certi- Code Voltage Code Lens Code Lens Code Entries Code Tag/ Code Initiate Code Finish Code SM8 fication colour guard duty label Option Xenon ATEX B DC 4 V 04 Red R None N 0 mm None N Telephone T Red R (stainless UL UL DC 48 V 048 Blue B Yes Y 5 mm Yes Y Relay R Blue B steel) HXBS CSA C AC 0 V 0 Green G / NPT EOL Yellow Y Xenon (alloy) HXBA GOST R ) G AC 0 V 0 Amber A /4 NPT 4 Resistor E Yellow/ Xenon High GOST K K AC 0 V 0 Yellow Top T ) None N Black Temp. (alloy) XBTA Chinese AC 40 V 40 (not LED)Y Bottom B ) stripe X Xenon High (CQST) Q AC 54 V 54 Clear RHS R ) Grey G Temp. (not LED)C White W (stainless LHS L ) Special steel) XBTS finish S LED Ex d (stainless steel) LEDS LED Ex d (alloy) LEDA ) Only HXBS is available CSA certified. Only HXBA & XBTA is available UL certified. ) Prefix position with entry size code. e.g. RB = 0 mm Right and Bottom entries. * For more options see or contact your local representative 8 0 COOPER CROUSE-HINDS GMBH 5.

86 I Ex-5 joule flashing xenon I XB XB with exlink Technical data XB EC-Type Examination Certificate BAS ATEX 5X/ Marking to 4//EC II G/D Ex d IIB T4* UL Listed for USA and Canada Class I, Div, Groups C & D Class I, Zones & AExd IIB T4/T5 UL Listing No E884 GOST R Certification Exd IIB T4/T5//T6 Chinese (CSQT) Certification Exd IIB T5/T6 Enclosure material Corrosion-free GRP Lens material Glass Finish Natural black or painted to customer specification Rated voltage 4 V DC/0-40 V AC 50/ Hz Power consumption tube 5 joule DC 4 V 8 W / AC 0 V W / AC 40 V 8 W Initiation Optional telephone or relays initiated Entries up to x M0 / up to x / NPT Weight.5 kg Rated terminal cross section 6 x.5 mm Protection category to EN 5 IP66/IP6 Permissible ambient temperature* T6 T85 C: -55 C to +40 C T5 T00 C: -55 C to +55 C T4 T5 C: -55 C to +0 C Dimension drawing 00 0 Entry,L Entry,R Dimensions in mm 5 05,5 0 Ø COOPER CROUSE-HINDS GMBH

87 I Ex-5 joule flashing xenon I Ordering details XB with exlink XB Catalogue No. Certification Description Ordering Code XBB0406ANBNNNN ATEX EX II GD GRP, natural black body, no tag or duty labels, backstrap mounting, PX 80 Ex d IIB 4 V DC, amber lens x M0 entries, flashes per minute XBB0406RNBNNNN ATEX EX II GD GRP, natural black body, no tag or duty labels, backstrap mounting, PX 80 Ex d IIB 40 AC, red lens, x M0 entries, flashes per minute XBB4006ANBNNNN ATEX EX II GD GRP, natural black body, no tag or duty labels, backstrap mounting, PX 804 Ex d IIB 40 V AC, amber lens, x M0 entries, flashes per minute XBUL0406ANBNNNR UL, cul Listed, No tag or duty labels,, 4 V DC, amber lens, x /" NPT entries, PX 86 Class I, Div, flashes per minute, black finish Groups C & D XBUL0406CNBNNNN UL, cul Listed, No tag or duty labels, 4 V DC, clear lens, x /" NPT entries, PX 86 Class I, Div, flashes per minute, black finish Groups C & D XBUL0406CNBNNNR UL, cul Listed, No tag or duty labels, 4 V DC, clear lens, x /" NPT entries, PX 864 Class I, Div, flashes per minute, red finish Groups C & D XBUL0406RNBNNNR UL, cul Listed, No tag or duty labels, 4 V DC, red lens, x /" NPT entries, PX 86 Class I, Div, flashes per minute, red finish Groups C & D XBUL006RNBNNNR UL, cul Listed, No tag or duty labels, 0 V AC, red lens, x /" NPT entries, PX 865 Class I, Div, flashes per minute, red finish Groups C & D Ordering options* Model Certification Code Voltage Code Flash rate Code Lens colour Code Lens guard Code XB ATEX B DC 4 V 04 /min. 06 Red R None N UL UL DC 48 V 048 Blue B Yes Y ATEX/UL AC 0 V 0 Green G Dual Listed AU AC 0 V 0 Amber A GOST R G AC 40 V 40 Yellow Y Chinese Clear C (CQST) Q Ordering options* 8 Unit fixing Code Earth continuity Code Tag/Duty label Code Options Code Finish Code Direct mounting D None N None N Telephone initiate T Natural Black N Backstrap B Yes Y Yes Y Blanking plug P Red R None N Blue B Yellow Y Grey G White W Special finish S * For more options see or contact your local representative 0 COOPER CROUSE-HINDS GMBH 5.5

88 I Ex-0/5 Joule flashing xenon I XB 0 Technical data XB 0 Marking to 4//EC II G Ex d IIB T4 II G Ex de IIB T4 EC-Type Examination Certificate BAS 00 ATEX 04X (Ex d) BAS 00 ATEX 6X (Ex ed) GOST R Certification Exd IIB T4/Exde IIB T4 Russian Fire Alarm Approved (VNIIPO) Permissible ambient temperature from -55 C to +40 C (Ex d)/from -50 C to +40 C (Ex de) Rated voltage 4-48 V DC/0-54 V AC 50/ Hz Power consumption (tube energy 5 joule) DC 4 V 6.8 ma / DC 48 V 6.8 ma AC 0 V madc / AC 0-54 V 4.8 ma Flash rate Hz Entries entries, M0 (Ex d)/ entries, M0 (Ex de) Rated terminal cross section 4 x.5 mm (DC)/6 x.5 mm (AC) Protection category to EN 5 IP66/IP6 Weight.8 kg (Ex d)/.6 kg (Ex de) Enclosure material Corrosion-free GRP Lens material Toughened glass with lens guard Finish Natural black or painted to customer specification Initiation Optional telephone or relays initiated 5.6 COOPER CROUSE-HINDS GMBH

89 I Ex-0/5 Joule flashing xenon I Ordering details XB 0 Catalogue No. Certification Description Ordering Code XB0D04FRNNBN ATEX Approved 5 joules, 4 V DC, red lens, bracket mounting, x M0 Entries, PX 8050 Ex II G, Exd, IIB, T5 black body, GRP body, flashes/min., no labels XB0D04FANNBN ATEX Approved 5 joules, 4 V DC, amber lens, bracket mounting, x M0 Entries, PX 805 Ex II G, Exd, IIB, T5 black body, GRP body, flashes/min., no labels XB0D40FRNNBN ATEX Approved 5 joules, 40 V DC, red lens, bracket mounting, x M0 Entries, PX 805 Ex II G, Exd, IIB, T5 black body, GRP body, flashes/min., no labels XB0D40FANNBN ATEX Approved 5 joules, 40 V DC, amber lens, bracket mounting, x M0 Entries, PX 805 Ex II G, Exd, IIB, T5 black body, GRP body, flashes/min., no labels Ordering options* 4 5 Model Certification Code Voltage Code Power Code Lens Code Labels Code Options Code Entries Code Finish Code Colour XB0 Ex d D DC 4 V 04 0J T Red R None N Telephone x M0 B Natural Black N Ex de E DC 48 V 048 5J F Blue B Yes Y Initiate T x PG.5 P Red R GOST R Exd DG* AC 0 V 0 Green G Earth x M0 B Blue B GOST R Exe EG* AC 0 V 0 Yellow Y continuity E x M0 B Yellow Y AC 40 V 40 Amber A m cable Grey G AC 54 V 54 Clear C tail G White W None N Special finish S * For more options see or contact your local representative Dimension drawing 6 EExd Version EExde Version 8 Ø , Pos. A 45 5,5 Pos. B Pos. C Dimensions in mm COOPER CROUSE-HINDS GMBH 5.

90 I Ex-5 joule flashing xenon I Pole mounting Direct mounting XB 5 with exlink Technical data XB 5 Marking to 4//EC II G/D Ex d IIC T* EC-Type Examination Certificate Baseefa 04 ATEX 000X UL Listed for USA and Canada Class I, Div, Groups A, B, C & D Class I, Zone, AExd IIC T4/T5 UL listing No. E884 Permissible ambient temperature* T6 T85 C: -55 C to +40 C T5 T00 C: -55 C to +55 C T4 T5 C: -55 C to +0 C Rated voltage 4-48 V DC/0-54 V AC 50/ Hz Rated current DC V.4 A (tube energy 5 joule) DC 4 V. A DC 48 V 0.4 A AC 0-0 V 0.4 A AC 0-40 V 0. A AC 54 V 0. A Flash rate fpm, 80 fpm, 0 fpm Insulation class I Protection category to EN 5 IP66/IP6 Weight.0 kg Enclosure material Corrosion-free GRP Lens material Glass Entries entries M0 (standard) / up to x / or /4 NPT Finish Natural black or painted to customer specification Initiation Optional telephone or relays initiated Rated terminal cross section x.5 mm (direct mount)/8 x.5 mm (pipe mount) Ordering options* Model Certi- Code Voltage Code Lens Code Lens Code Unit Code Fixing Code Unit Code Finish Code fication flashrate colour guard options XB 5 ATEX B DC V 0 06 Red R None N Pipe mount P None N Natural black N UL UL DC 4 V Blue B Cast C Direct mount D Tag label T Red R DC 48 V Green G Wire W Direct w. Duty label D Blue B AC 0 V 0 Amber A backstrap B Relay initiate R Yellow Y AC 0 V 0 Yellow Y Telephone Green G AC 0 V 0 Clear C initiate I White W AC 40 V 40 Blanking Special finish S AC 54 V 54 plug P * For more options see or contact your local representative 5.8 COOPER CROUSE-HINDS GMBH

91 I Ex-5 joule flashing xenon I Ordering details XB 5 with exlink Direct mounting Pole mounting Catalogue No. Certification Description Ordering Code XB5UL0406AWBNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, backstrap, PX 0046 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, amber lens XB5UL0406AWPNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, pipe mounting, PX 005 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, amber lens XB5UL0406BWBNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, backstrap, PX 0044 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, blue lens XB5UL0406BWPNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, pipe mounting, PX 004 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, blue lens XB5UL0406CWBNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, backstrap, PX 004 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, clear lens XB5UL0406CWPNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, pipe mounting, PX 004 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, clear lens XB5UL0406GWBNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, backstrap, PX 004 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, green lens XB5UL0406GWPNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, pipe mounting, PX 0048 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, green lens XB5UL0406RWBNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, backstrap, PX 0045 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, red lens XB5UL0406RWPNN UL, cul Listed, Class I, 4 V DC, flashes per minute, wire guard, pipe mounting, PX 0050 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, red lens XB5UL006AWBNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, backstrap, PX 0056 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, amber lens XB5UL006AWPNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, pipe mounting, PX 00 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, amber lens XB5UL006BWBNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, backstrap, PX 0054 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, blue lens XB5UL006BWPNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, pipe mounting, PX 005 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, blue lens XB5UL006CWBNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, backstrap, PX 005 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, clear lens XB5UL006CWPNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, pipe mounting, PX 005 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, clear lens XB5UL006GWBNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, backstrap, PX 005 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, green lens XB5UL006GWPNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, pipe mounting, PX 0058 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, green lens XB5UL006RWBNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, backstrap, PX 0055 Div, Groups A, B, C, D x /" NPT entries, natural black enclosure, red lens XB5UL006RWPNN UL, cul Listed, Class I, 0 V AC, flashes per minute, wire guard, pipe mounting, PX 00 Div, Groups A, B, C, D x /4" NPT entry, natural black enclosure, red lens Dimension drawing ,5 8 Entry,R Direct mounting Entry,L Entry,L Ø50 Pole mounting 6.5 A/F Dimensions in mm COOPER CROUSE-HINDS GMBH 5.

92 I Ex- joule flashing xenon I XB 4 Technical data XB 4 Marking to 4//EC II G Ex d IIC T5 EC-Type Examination Certificate Baseefa 0 ATEX 04X UL Listed for USA and Canada Class I, Div, Groups C-D Class I, Zone Listing No. E884 GOST R Certification Exd IIC T4 Russian Fire Approved (VNIIPO) Permissible ambient temperature UL -5 C to +0 C ATEX & GOST -50 C to +55 C (Exde) -55 C to +55 C (Exd) Rated voltage 4-0 V DC/0-54 V AC 50/ Hz Rated current DC 4 V.4 A (tube energy joule) DC 48 V 0.54 A DC 0 V 0.4 A AC 0 V 0.5 A AC 0 V 0.45 A AC 0 V 0.4 A AC 40 V 0.85 A AC 54 V 0. A Protection category to EN 5 IP66/IP6 Finish Red epoxy painted finish as standard Initiation Optional telephone or relays initiated Flash rate fpm, 0 fpm, 40 fpm Entries up to entries, M0 or entries M5 / / or /4 NPT Weight 6.6 kg Enclosure material Marine grade alloy or stainless steel Lens material Toughened glass Rated terminal cross section 8 x 0 mm * Optional with lens guard Dimension drawing 0 Ø Ø Dimensions in mm 5.0 COOPER CROUSE-HINDS GMBH

93 I Ex- joule flashing xenon I Ordering details XB 4 Catalogue No. Certification Description Ordering Code XB4BB8DBB06AN0RNR ATEX Approved Ex II G joules, 4 V DC, red lens, x M0 entries, 55Cd, PX 8400 flashes per minute, no labels, red finish XB4BH8DBB06AN0RNR ATEX Approved Ex II G joules, 40 V AC, red lens, x M0 entries, 55Cd, PX 8400 flashes per minute, no labels, red finish XB4ULB8DEE06ANANR UL, cul Listed, Class I, Marine grade alloy, 4 V DC, amber lens, x /4" NPT entries, PX 86 Div, Groups C & D no lens guard, flashes per minute, red finish XB4ULB8DEE06ANRNR UL, cul Listed, Class I, Marine grade alloy, 4 V DC, red lens, x /4" NPT entries, PX 86 Div, Groups C & D no lens guard, flashes per minute, red finish XB4ULE8DEE06ANANR UL, cul Listed, Class I, Marine grade alloy, 0 V AC, amber lens, x /4" NPT entries, PX 866 Div, Groups C & D no lens guard, flashes per minute, red finish XB4ULE8DEE06ANRNR UL, cul Listed, Class I, Marine grade alloy, 0 V AC, red lens, x /4" NPT entries, PX 865 Div, Groups C & D no lens guard, flashes per minute, red finish Ordering options* Model Certification Code Voltage Code Terminals Code Cable entries Code Lens flashrate Code XB 04 ATEX B DC 4 V B 6 x 6 mm 6E 0 mm B 06 UL UL ) DC 48 V C 8 x 0 mm 8D 5 mm GOST R G DC 0 V D / NPT D ) 0 AC 0 V E /4 NPT E ) AC 0 V F AC 0 V G AC 40 V H AC 54 V J Ordering options* Initiate options Code Lens colour Code Tag/Duty label Code Material Code Finish Code None A Red R None N Stainless steel 0 Red R Telephone B Blue B Yes Y Alloy Blue B Telephone & Green G Yellow Y. beacon Relay D Amber A Green G Relay &. beacon E Yellow Y White W Clear C Special finish S * For more options see or contact your local representative ) UL available alloy or stainless steel. 4V DC, 0 V AC; 40 V AC only. ) Prefix entry size with entry position code e.g. BB COOPER CROUSE-HINDS GMBH 5.

94 I Ex- joule flashing xenon I XB XB with exlink Technical data XB Marking to 4//EC II G Ex d IIB T4/T5 T5 C/T00 C EC-Type Examination Certificate BAS ATEX 6/ UL Listed for USA and Canada Class I, Div, Groups C & D Class I, Zones & AExd IIB T4 & T5 UL Listing No. E884 GOST R Certification Exd IIB T4/T5 GOST K Certification Ex d IIB T4/T5 Chinese (CQST) Certification Ex d IIB T4/T5 Permissible ambient temperature Certified Exd -55 C to +0 C (T4) -55 C to +40 C (T5) Temperature UL -55 C to +0 C Rated voltage 4 V DC/0-40 V AC 50/ Hz Rated current tube joule DC 4 V.4 A AC 48 V 0.5 A AC 40 V 0.85 A Protection category to EN 5 IP66/IP6 Weight kg Enclosure material Corrosion-free GRP Lens material Glass Finish Natural black or painted to customer specification Initiation Optional telephone or relays initiated Flash rate fpm Entries up to entries M0 / / NPT Rated terminal cross section 6 x 6 mm ) Optional with lens guard Dimension drawing Entry,L Entry,R Dimensions in mm 5 45,5 5,5 0 0 Ø 4 5. COOPER CROUSE-HINDS GMBH

95 I Ex- joule flashing xenon I Ordering details XB with exlink XB Catalogue No. Certification Description Ordering Code XBB0406ANBNNNN ATEX Approved Ex II G 4 V DC, flashes per minute, amber lens, no wire guard, PX 80 backstrap mounting, no labels, black body XBB0406RNBNNNN ATEX Approved Ex II G 4 V CD, flashes per minute, red lens, no wire guard, PX 80 backstrap mounting, no labels, black body XBB4006ANBNNNN ATEX Approved Ex II G 40 V AC, flashes per minute, amber lens, no wire guard, PX 804 backstrap mounting, no labels, black body XBB4006RNBNNNN ATEX Approved Ex II G 40 V AC, flashes per minute, red lens, no wire guard, PX 80 backstrap mounting, no labels, black body XBUL0406ANBNNNR UL, cul Listed, Class I, 4 V DC, flashes per minute, amber lens, no wire guard, PX 868 Div, Groups C & D backstrap mounting, no labels, red painted GRP XBUL0406RNBNNNR UL, cul Listed, Class I, 4 V DC, flashes per minute, amber lens, no wire guard, PX 868 Div, Groups C & D backstrap mounting, no labels, red painted GRP XBUL006ANBNNNR UL, cul Listed, Class I, 0 V AC, flashes per minute, amber lens, no wire guard, PX 8686 Div, Groups C & D backstrap mounting, no labels, red painted GRP XBUL006RNBNNNR UL, cul Listed, Class I, 0 V AC, flashes per minute, red lens, no wire guard, PX 8685 Div, Groups C & D backstrap mounting, no labels, red painted GRP Ordering options* Model Certification Code Voltage Code Lens flashrate Code Lens colour Code Lens guard Code XB ATEX B DC 4 V 4 06 Red R None N UL UL AC 0 V 0 Blue B Yes Y GOST R G AC 40 V 40 Green G GOST K K Amber A Chinese Yellow Y (CQST) Q Clear C Ordering options* 8 Unit fixing Code Earth continuity Code Tag/Duty label Code Options Code Finish Code Direct mounting D None N None N Telephone T Natural black N Backstrap B Yes Y Yes Y Blanking plug P Red R None N Blue B Yellow Y Green G White W Special finish S * For more options see or contact your local representative 0 COOPER CROUSE-HINDS GMBH 5.

96 I Ex-5 joule sequenced and 0 W rotating I XB 5/TH 5 Technical data XB 5 TH 5 Marking to 4//EC II G Ex d IIB T* / II G Ex de IIB T* EC-Type Examination Certificate Baseefa 00 ATEX 05X Permissible ambient temperature* XB5 T6-0 C to +40 C TH5 T4-0 C to +55 C Rated voltage XB 5 (5 W flashing Xenon tubes) 4-0 V DC; 0-54 V AC 50/ Hz TH 5 (55/0 W rotating mirror) - 4 V DC; 0-40 V AC 50/ Hz Peak current consumption XB 5 DC 4 V. A / DC 48 V 0.65 A (5 W flashing Xenon tube) DC 0 V 0. A / AC 0 V 0.5 A AC 0 V 0.45 A / AC 0 V 0.4 A AC 40 V 0. A / AC 54 V 0. A Insulation class I Rated terminal cross section 6 x 6 mm (Ex e & Ex d) Protection category to EN 5 IP66/IP6/IP68 Enclosure material Marine grade alloy and GRP (Ex e terminal chamber) Lens material Toughened glass ) Weight XB 5 (Ex d) 4.6 kg / XB 5 (Ex de) 5.6 kg TH 5 (Ex d) 4. kg / TH 5 (Ex de) 5. kg Finish Epoxy paint finish as standard or specified Power consumption TH 5 DC V 55 W Rotating mirror DC 4 V 0 W DC 0-40 V 0 W Entries up to x M0 or x M5 (Ex d) or up to 4 x M0 or M5 (Ex e) ) Optional with lens guard Ordering options* Model Speed Code Terminal Code Voltage Code Cable Code Lens Code Tag label Code Guard Code Finish Code chamber entries colour XB 5 rpm Ex d D V DC A 0 mm B Red R None N None 0 Grey G TH 5 0 rpm Ex e E 4 V DC B 5 mm C Blue B Yes Y Guard Red R 80 rpm ) 48 V DC C Green G Blue B 0 V DC D Yellow Y Yellow Y 0 V AC E Amber A White W 0 V AC F Clear C Special finish S 0 V AC G 40 V AC H 54 V AC J ) * For more options see or contact your local representative ) not for 0 V ) not for TH 5 Dimension drawing Top View 5 Front View with EExe chamber Part Front View EExd only Dimensions in mm 5.4 COOPER CROUSE-HINDS GMBH

97 I Ex-55/0 W rotating beacon I Technical data TH Marking to 4//EC II G Ex d IIB T4/T5 T5 C/T00 C* EC-Type Examination Certificate Baseefa ATEX 6/ GOST R Certified Exd IIB T4/T5 Permissible ambient temperature* T4: from -55 C to +0 C / T5: from -55 C to +40 C Rated voltage - 4 V DC/0-40 V AC 50/ Hz Rated wattage DC V 55 W H tungsten halogen bulb DC 4 V 0 W H tungsten halogen bulb AC 0 V 0 W H tungsten halogen bulb AC 40 V 0 W H tungsten halogen bulb Protection category to EN 5 IP66/IP6 Rated terminal cross section 6 x 6 mm Enclosure material Corrosion-free GRP Lens material Glass ) Finish Natural black or painted to customer specification Rotating beacon speed r.p.m., 0 r.p.m., 80 r.p.m. Entries up to x M0 Weight.6 kg ) Optional with lens guard TH Ordering details Catalogue No. Certification Description Ordering Code THB04RNBNN ATEX Approved Ex II G, GRP Body black, 0W Rotating Tungsten Halogen Lamp, PX 8500 Ex d IIB T4/T5, rpm., 4V DC, 50 Cd, Red lens, no lens guard Zone & Backstrap mounting Ordering options* Model Certification Code Speed Code Voltage Code Lens Code Lens Code Unit Code Options Code Finish Code colour guard fixing TH ATEX B rpm A DC V 0 Red R None N Direct Tag label T Natural black N GOST R G 0 rpm B DC 4 V 04 Blue B Yes Y mounting D Duty label D Red R 80 rpm C AC 0 V 0 Green G Backstrap B Earth Blue B AC 40 V 40 Amber A continuity E Yellow Y Yelllow Y None N Green G Clear C White W Special finish S * For more options see or contact your local representative Dimension drawing ,5 5,5 0 Entry,L 0 Ø 4 Entry,R Dimensions in mm COOPER CROUSE-HINDS GMBH 5.5

98 I Ex-0.5 joule flashing xenon I XB 8 Technical data XB 8 Marking to 4//EC II G Ex ia IIB or Ex II G Ex ia IIC T4 EC-Type Examination Certificate BAS 00 ATEX 58X GOST R Certification 0EX ia IIB T4 0Ex ia IIC T4 Cert. No. A-05 Permissible ambient temperature from -55 C to + C Rated voltage - 4 V DC via suitable barrier Power consumption DC V 5 ma max. nom. (IIB & IIC) (tube energy 0.5 joule) DC 4 V 55 ma max. nom. (IIC)/ ma max. nom. (IIB) Insulation class Protection category to EN 5 IP66/IP6 Weight.4 kg Enclosure material Corrosion-free GRP Lens material Polycarbonate, clear Finish Natural red Flash rate Hz Entries entries, M0 via knockouts Rated terminal cross section 8 x.5 mm Ordering details Catalogue No. Description Ordering Code XB8CNR Intrinsic safe IIB, 4 V DC, lens colour clear 8800 Ordering options* Model Certification Code Voltage Code Lens colour Code Tag/duty label Code Finish Code XB 8 ATEX IIB BB V Clear C Duty D Natural red N ATEX IIC BC 4 V 4 Special S Tag T Special S GOST R IIB GB None N GOST R IIC GC * For more options see or contact your local representative Dimension drawing Entry A Entry B Entry C Ø Dimensions in mm 5.6 COOPER CROUSE-HINDS GMBH

99 COOPER CROUSE-HINDS GMBH 5.

100 I Ex-0 W steady filament/fluorescent I SM 8 LU/LU Technical data SM 8 LU/LU Marking to 4//EC II G/D Ex d IIC ) EC-Type Examination Certificate Baseefa 0 ATEX 0 UL Listed for USA & Canada Class I, Div., Groups C & D Class I, Zone Listing No. E884 SM8LU & LU CSA Certified Class, Div. &, Group D Certification No CSA Certification to C. Nos. 0, 0.4, 0.5,, 0 M86, 4 M, M8, Class, Group D, Enclosure /4 Cert. No GOST R Certification Exd IIC T4 Certification No. A-056 (SM8 Alloy only) Chinese (CQST) Certification Exd IIC T4/T5/T6 (LU & LU only) Permissible ambient temperature LU T4 (5 C) -55 C to +40 C T (00 C) -55 C to +55 C LU T6 (85 C) -55 C to +40 C T5 (5 W) -55 C to +55 C T4 (0 W) -55 C to +55 C Rated voltage 4-48 V DC/0-54 V AC 50/ Hz Rated terminal cross section 4 x.5 mm Power consumption LU 0 W (Filament lamp) Power consumption LU DC 4 V - 0 V 5 W (Fluorescent lamp) AC 40 V - 54 V 0 W (Fluorescent lamp) Protection category to EN 5 IP66/IP6 Entries LU: up to 4 x M0 or M5/LU: up to x M0 or M5 Weight Alloy:.5 kg / Stainless steel:.8 kg Enclosure material Marine grade alloy or stainless steel Lens material Glass Finish Red epoxy painted finish as standard Initiation Telephone or relays initiated 5.8 COOPER CROUSE-HINDS GMBH

101 I Ex-0 W steady filament/fluorescent I Ordering details SM 8 LU/LU Catalogue No. Certification Description Ordering Code SM8LUAUL04GN4T4BNR UL, cul Listed, Class I, 4V DC, green lens, 0 W fluorescent bulb, PX 4005 Div, Groups C & D marine grade alloy, red finish SM8LUAUL04RN4T4BNR UL, cul Listed, Class I, 4V DC, red lens, x /4" NPT entries, no labels, red finish PX Div, Groups C & D SM8LUAUL04GNTBNR UL, cul Listed, Class I, 4V DC, green lens, 0 W incandescent bulb, PX 4006 Div, Groups C & D marine grade alloy, red finish SM8LUAUL04RNRLNR UL, cul Listed, Class I, 4V DC, red lens, x /" NPT entries, no labels, red finish PX 6 Div, Groups C & D Ordering options* 4 5 Model Code Certification Code Voltage Code Lens Code Lens Code Cable Code Tag/duty Code Finish Code SM 8... colour guard entries label Fluorescent Ex d LUA ATEX B DC 4 V 04 Red R None N 0 mm None N Red R Fluorescent Ex d UL Listed UL DC 48 V 048 Blue B Yes Y 5 mm Yes Y Blue B (Stainless steel) LUS ) CSA Certified C AC 0 V 0 Green G Other Yellow Y Filament Ex d LUA ) GOST R AC 0 V 0 Amber A Top T Yellow/ (Alloy) Certified G AC 40 V 40 Yellow Y BottomB black Filament Ex d Chinese (CQST)Q AC 54 V 54 Clear C RHS R ) stripes X (Stainless steel) LUS ) LHS L Green G White W Special finish S * For more options see or contact your local representative ) not available on SM 8 LU ) not available UL or GOST certified ) not available CSA certified 6 8 Dimension drawing 05,5 0,5 05,5 0,5 Ø 0,5 0 0 (S) (A) 80 (S) 0 (A) 55 (S) 6 (A) 8 (S) 0 (A) Dimensions in mm COOPER CROUSE-HINDS GMBH 5.

102 I Ex-0 W steady filament/fluorescent I FB /FL Technical data FB FL Marking to 4//EC II G/D Ex d IIB T ) EC-Type Examination Certificate BAS ATEX 5X UL Listed for USA and Canada Class I, Div., Groups C & D and (FB only) Class I, Zone, AExd IIB T4/T5 UL Listing No. E884 GOST R Ex d IIB (for T ratings see table) Permissible ambient temperature ) FB (T00 C) T5-55 C to +40 C (T5 C) T4-55 C to +55 C FL (T00 C) T5-0 C to +40 C (T5 C) T4-0 C to +55 C Rated voltage 4-48 V DC/0-40 V AC 50/ Hz Rated lamp type FB 0 W (Filament lamp) Rated lamp type FL DC 4 V 5 W lamp AC 54 V 0 W lamp Protection category to EN 5 IP66/IP6 Weight.5 kg Enclosure material Corrosion-free GRP Lens material Glass Finish Natural black or painted to customer specification Entries up to x M0 / x / NPT Rated terminal cross section 4 x.5 mm (FL AC)/6 x.5 mm (FL DC & FB ) 5.40 COOPER CROUSE-HINDS GMBH

103 I Ex-0 W steady filament/fluorescent I Ordering details FB /FL Catalogue No. Certification Description Ordering Code FBB040RNBNNN ATEX 4 V DC, 0 W incandescent beacon, red lens, PX mounting bracket, natural black finish FBUL040GNBNNR UL, cul Listed, Class I, 0 W incandescent beacon, 4 V DC, green lens, PX Div, Groups C & D no lens guard, x /" NPT entries, painted red enclosure FBUL00GNBNNR UL, cul Listed, Class I, 0 W incandescent beacon, 0 V AC, green lens, PX 5000 Div, Groups C & D no lens guard, x /" NPT, painted red enclosure Ordering options* Model Certi- Code Voltage Code Lamp Code Lens Code Lens Code Unit Code Earth Code Tag/ Code Finish Code fication wattage colour guard fixing conti- duty nuity label FB ATEX B DC 4 V 04 FL 5 W DC 5 Red R None N Direct None N None N Red R FL UL DC 48 V 048 FL 0 W AC 0 Blue B Yes Y mounting D Yes Y Yes Y Blue B Listed ) UL AC 0 V 0 FB 0 W AC 0 Green G Backstrap B Yellow Y GOST AC 0 V 0 Amber A Yellow/black R R AC 0 V 0 Yellow Y stripes X AC 40 V 40 Clear C Green G AC 54 V 54 White W Special finish S * For more options see or contact your local representative ) UL listed only available FB Dimension drawing ,5 Entry,L Entry,R 0 0 Ø 6 COOPER CROUSE-HINDS GMBH 5.4 Dimensions in mm

104 I Ex-00 W steady filament and W fluorescent I FL 4 FB 4 Technical data FB 4 FL 4 EC-Type Examination Certificate Baseefa 0 ATEX 04X Marking to 4//EC II G Ex d IIC T ) II G Ex e IIC T ) UL Listed for USA and Canada Class I, Div., Groups C & D Class I, Zone AExd IIB T4/T5 Listing No. E884 GOST R Certified Ex d IIC T/T4/T5 Enclosure material Marine grade alloy or stainless steel and GRP (Ex e terminal chamber) Lens material Toughened glass Finish Grey epoxy paint finish as standard Rated voltage 4-0 V DC/0-54 V AC 50/ Hz Lamps FL 4 up to x W PL compact fluorescent lamps FB 4 up to 00 W GLS filament lamps, E holder as standard Entries up to x M0 (Ex d) or up to 4 x M0 (Ex e) Weight FL 4 (Ex d) Alloy: kg / Stainless steel: approx. 8.4 kg FL 4 (Ex de) Alloy:.5-8. kg / Stainless steel: approx. 8.4 kg FB 4 (Ex d) Alloy: 6.4 kg / Stainless steel: approx. 8.4 kg FB 4 (Ex de) Alloy:.4 kg / Stainless steel: approx. 8.4 kg Rated terminal cross section 6 x 6 mm or 0 x.5 mm (Ex e), 8 x 0 mm (Ex d) Protection category to EN 5 IP66/IP6 Permissible ambient temperature ) FL 4 DC T5-0 C to +55 C AC T4-0 C to +55 C FB 4 W T4-55 C to +40 C (Ex d) / -50 C to +40 C (Ex e) 00 W T -55 C to +55 C (Ex d) / -50 C to +40 C (Ex e) 5.4 COOPER CROUSE-HINDS GMBH

105 I Ex-00 W steady filament and W fluorescent I Ordering details FB 4 FL 4 Catalogue No. Certification Description Ordering Code FB4EUL8UN00BNG UL, cul Listed, Class I, Marine grade alloy, 0 V AC, 00 W bulb (not included), PX Div, Groups C & D blue lens, lens guard, no labels, gray finish FL4BUL8UMMRNRZ UL Listed, Class I, Div, Marine grade alloy, 4 V DC, x /" NPT entries, PX Groups C & D W tube (not included), red lens, lens guard, red finish, one certified plug 4 Ordering options* Model Certi- Code Voltage Code Terminals Code Cable Code Lamp Code Lens Code Guard Code OptionsCode Material Code Finish Code fication entries wattage colour FB 4 ATEX B DC 4 V BB 6 x 6 mm 6E 0 mm B FL 4 Red R None 0 Duty D Stainless Grey G FL 4 UL UL DC 48 V CB 8 x 0 mm 8D 5 mm C x W Blue B Guard Y Tag T steel 0 Red R GOST DC 0 V DB / NPT M ) x W 6 Green G None N Alloy Blue B R G AC 0 V EB /4 NPT N ) x W Amber A Yellow Y AC 0 V FB FB 4 Yellow Y White W AC 0 V GB W Clear C Special AC 40 V HB 00 W 00 finish S AC 54 V IB * For more options see or contact your local representative ) UL certified only COOPER CROUSE-HINDS GMBH 5.4

106 I Ex-00 W steady filament and W Fluorescent I FB /FL FL with exlink Technical data FB FL Marking to 4//EC II G/D Ex d IIB T EC-Type Examination Certificate BAS ATEX 6 UL Listed for USA and Canada Class I, Div., Groups C & D and (FB only) Class I, Zone, AExd IIB T4/T5 UL Listing No. E884 GOST R Exd IIB (for T ratings see table) Permissible ambient temperature FB W T5: -55 C to +40 C T4: -55 C to +55 C 00 W T: -55 C to +0 C FL W AC/DC T6: -0 C to +40 C W AC T5: -0 C to +55 C 6 W AC T5: -0 C to +40 C 6 W AC T4: -0 C to +55 C W AC T4: -0 C to +40 C Rated voltage 4 V DC/0-40 V AC 50/ Hz Rated lamp type FB W filament lamp 00 W filament lamp Rated lamp type FL W fluorescent lamp Rated terminal cross section 6 x 6 mm Enclosure material Corrosion-free GRP Protection category to EN 5 IP66/IP6 Weight. kg (FL ) /.6 kg (FB ) Lens material Glass Finish Natural black or painted to customer specification Entries up to entries, M0 / x / NPT 5.44 COOPER CROUSE-HINDS GMBH

107 I Ex-00 W steady filament and W Fluorescent I Ordering details FL with exlink FB /FL Catalogue No. Certification Description Ordering Code FBUL04GNBNNR UL, cul Listed, Class I, W incandescent beacon, 4V DC, green lens, PX 006 Div, Groups C & D no lens guard, x /" NPT entries, painted red enclosure FBUL000GNBNNR UL, cul Listed, Class I, 00W incandescent beacon, 4V DC, green lens, PX 00 Div, Groups C & D no lens guard, x /" NPT entries, painted red enclosure FBUL0CNBNNN UL, cul Listed, Class I, 0V AC, W incandescent beacon, clear lens, PX Div, Groups C & D mounting bracket, no labels, natural black finish FBUL0GNBNNR UL, cul Listed, Class I, W incandescent beacon, 0V AC, green lens, PX 005 Div, Groups C & D no lens guard, x /" NPT entries, painted red enclosure Ordering options* 4 5 Model Certi- Code Voltage Code Lamp Code Lens Code Lens Code Unit Code Earth Code Tag/ Code Finish Code fication wattage colour guard fixing conti- duty nuity label FB ATEX B DC 4 V 04 FL x W Red R None N Direct None N None N Red R FL UL DC 48 V 048 FL x W 6 Blue B Yes Y mounting D Yes Y Yes Y Blue B Listed ) UL AC 0 V 0 FL x W Green G Backstrap B Yellow Y GOST AC 0 V 0 FB W Amber A Yellow/black R R AC 0 V 0 FB 00 W 00 Yellow Y stripes X AC 40 V 40 Clear C Green G AC 54 V 54 White W Special finish S * For more options see or contact your local representative ) UL listed only available FB Dimension drawing Entry,L Entry,R 5 45,5 5,5 0 0 Ø 4 0 COOPER CROUSE-HINDS GMBH 5.45 Dimensions in mm

108 I Ex-/00 W steady filament I Pole mounting Direct mounting Technical data FB 5 Marking to 4//EC II G/D Ex d IIC T ) EC-Type Examination Certificate BAS 04 ATEX 000X UL Listed for USA and Canada Class I, Div, Groups A, B, C & D Class I, Zone AExd IIC T/T4 UL listing No. E884 Permissible ambient temperature W (T5 C) T4-55 C to +55 C W (T00 C) T -55 C to +0 C 00 W (T5 C) T4-55 C to +40 C Rated voltage 4-48 V DC/0-54 V AC 50/ Hz Power consumption W/00 W filament Rated terminal cross section x.5 mm Protection category to EN 5 IP66/IP6 Entries up to x M0 or M5 (standard = x M0) Weight.0 kg Enclosure material Corrosion-free GRP Lens material Glass ) Finish Natural black or painted to customer specification ) Optional with lens guard Dimension drawing 00 Entry,L Ø50 Entry,R Entry,L 6.5 A/F Dimensions in mm , COOPER CROUSE-HINDS GMBH

109 I Ex-/00 W steady filament I Ordering details Direct mounting Pole mounting Catalogue No. Certification Description Ordering Code FB5UL0400ANPNN UL, cul Listed, Class I, 00 W incandescent beacon, 4 V DC, amber lens, no lens guard, PX 4005 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL0400BNPNN UL, cul Listed, Class I, 00 W incandescent beacon, 4 V DC, blue lens, no lens guard, PX 400 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL0400CNPNN UL, cul Listed, Class I, 00 W incandescent beacon, 4 V DC, clear lens, no lens guard, PX 4008 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL0400GNPNN UL, cul Listed, Class I, 00 W incandescent beacon, 4 V DC, green lens, no lens guard, PX 400 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL0400RNPNN UL, cul Listed, Class I, 00 W incandescent beacon, 4 V DC, red lens, no lens guard, PX 4006 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL000ANPNN UL, cul Listed, Class I, 00 W incandescent beacon, 0 V AC, amber lens, no lens guard, PX 4000 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL000BNPNN UL, cul Listed, Class I, 00 W incandescent beacon, 0 V AC, blue lens, no lens guard, PX 4004 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL000CNPNN UL, cul Listed, Class I, 00 W incandescent beacon, 0 V AC, clear lens, no lens guard, PX 400 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL000GNANR UL, cul Listed, Class I, 0 V AC, 00W incandescent beacon, green lens, PX 4000 Div, Groups A, B, C, D mounting bracket, no labels, red finish FB5UL000GNPNN UL, cul Listed, Class I, 00 W incandescent beacon, 0 V AC, green lens, no lens guard, PX 400 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure FB5UL000RNPNN UL, cul Listed, Class I, 00 W incandescent beacon, 0 V AC, red lens, no lens guard, PX 400 Div, Groups A, B, C, D pipe mounting, x /4" NPT entry, natural black enclosure Ordering options* Model Certi- Code Voltage Code Lamp Code Lens Code Lens Code Unit Code Tag/duty Code Finish Code fication wattage colour guard fixing label FB 5 ATEX B DC 4 V 04 W Red R None N Pipe None N Natural UL UL DC 48 V W 00 Blue B Cast C mount P ) Tag label T black N AC 0 V 0 Green G Wire W Direct Duty label D Red R AC 0 V 0 Amber A mount D Blanking Blue B AC 0 V 0 Yellow Y Direct w/ plug P Yellow Y AC 40 V 40 Clear C backstrapb Green G AC 54 V 54 White W Special finish S * For more options see or contact your local representative ) Not available on ATEX version 8 0 COOPER CROUSE-HINDS GMBH 5.4

110 I Ex-00 W steady filament and 5 W fluorescent I FB 5/FL 5/HS 5/MS 5 Technical data FB 5 FL 5 HS 5 MS 5 Marking to 4//EC II G Ex d IIB ) II G Ex de IIB ) EC-Type Examination Certificate Baseefa 0 ATEX 05X CSA certified Class I, Zone Ex d IIB T4 CSA certification to E-0-5, E---5, C. Nos..0-6 Certification No. LR6406 (HS5 only) Permissible ambient temperature FL5 T4: -0 C to +50 C FB5 T: -0 C to +0 C MF5 T: -0 C to +40 C HS5 T4: -0 C to +40 C Rated voltage 0-54 V AC 50/ Hz Rated terminal cross section 6 x 6 mm (Ex de), 8 x 0 mm (Ex d) Lamps FL 5 up to 4 x W PL compact fluorescent lamps FB 5 up to 00 W GLS filament lamps, E cap as standard MF 5 up to 80 W mercury fluorescent lamp HS 5 up to 0 W high pressure sodium lamp Protection category to EN 5 IP66/IP6 Entries up to x M0 or M5 (Ex d) or up to 4 x M0 or M5 (Ex e) Weight FL 4 (Ex d) Alloy: kg / Stainless steel: add. 8.4 kg FL 4 (Ex de) Alloy:.5-8. kg / Stainless steel: add. 8.4 kg FB 4 (Ex d) Alloy: 6.4 kg / Stainless steel: add. 8.4 kg FB 4 (Ex de) Alloy:.4 kg / Stainless steel: add. 8.4 kg Enclosure material Marine grade alloy or stainless steel and GRP (Ex e terminal chamber) Lens material Toughened glass (coloured if required) Finish Grey epoxy paint finish as standard ) Optional with lens guard Ordering options* Model Terminal Code Voltage Code Fixing Code Cable Code Lens Code Tag Code Material Code Finish Code chamber entries guard label FB 5 Ex d D 0 V AC G Backstrap B 0 mm B None 0 None N Stainless steel 0 Grey G FL 5 Ex de E 40 V AC H Stirrup S 5 mm C Guard Yes Y Alloy Red R MF 5 54 V AC J Blue B HS 5 Yellow Y White W Special finish S * For more options see or contact your local representative Dimension drawing Top View 5 Front View with EExe chamber Part Front View EExd only Dimensions in mm 5.48 COOPER CROUSE-HINDS GMBH

111 COOPER CROUSE-HINDS GMBH 5.4

112 E X - S O U N D E R S A N D H O R N S Explosion protected units for Zone 0,,,, Class I, Div &, GOST R & K This range of light weight, flameproof Sounders has been designed with a high weatherproof rating to cope with the harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical industries. New electronic circuitry allows the DBP and DBHP to be switched between two selectable tones by either reversing the supply polarity, or connecting a second voltage supply. The higher output DBH and DBHP are particularly suitable for noisy environments. The flamepaths, flare and the body, are manufactured completely from a UV stable glass reinforced polyester. Stainless steel screws and sinter are incorporated thus ensuring a corrosion free product. A tapered flamepath is used to overcome the problems of assembly of parallel spigot flamepaths. An optional Ex e terminal chamber is available. Optional Exe terminal chamber UL Listed for USA and Canada Hazardous locations: Class I, Div, Groups A-D. Class I, Zones &, AExd IIC T4. Ordinary locations: Audible-Signal Device. GOST R & K certified Chinese (CQST) certified Australian (SAA) certified IP66 and IP6 Certified temperature 55 C to +0 C All GRP corrosion free flamepaths Up to 8dBA output 5.50

113 I Ex-0 db(a) bell I Technical data DB 6 DB 6 Marking to 4//EC II G Ex d IIB T5 EC-Type Examination Certificate Baseefa 0 ATEX 05 Permissible ambient temperature -0 C to +55 C Rated voltage and Rated current 4 V DC 8 ma 00/54 V AC /5 ma 40 Hz/ Hz Contact spring Phosphor bronze Contacts Silver Coil Bakelite former Magnet Laminated iron Finish Grey epoxy paint finish as standard or to customer s specification Max. sound levels 4 V DC 8 ± db(a) 00/54 V AC 06 ± db(a) Protection category to EN 5 IP65 Entries x M0 mm ISO with one Ex d blank fitted Weight kg Enclosure material Cast iron Rated terminal cross section 4 x 4 mm Ordering details Catalogue No. Description Ordering Code DB6BNR Cast iron 8 db(a) output, red PX800 Ordering options* Unit Type Voltage Code Label Code Finish Code DB 6 4 V DC B None N Red R 40 V AC H Yes Y Grey G Special finish S ) ) Please specify * For more options see or contact your local representative Dimension drawing 8, ,5 5, Dimensions in mm COOPER CROUSE-HINDS GMBH 5.5

114 I Ex- db(a) sounder I DB Technical data DB Marking to 4//EC II G Ex d IIB T EC-Type Examination Certificate DB (P) Baseefa 0 ATEX 00 DB H (P) Baseefa 0 ATEX 00 UL Listing Class I, Div., Groups C & D Listing No. E8688 GOST R Certification Exd IIB T4 (DB & DBP only) Permissible ambient temperature DB & DBP -0 C to +55 C DB H & DBHP -0 C to +0 C Rated voltage and Rated current DC AC DB (P) V 4 V 48 V 0 V 40 V DB H (P) 5 ma 50 ma 50 ma ma 50 ma 00 ma 00 ma 00 ma 00 ma Resistor values 40 Ω minimum (DC only) Max. sound levels 0 ± db(a) DB (P) 6 ± db(a) DB (P) V 0 ± db(a) at m. ) DB H (P) Protection category to EN 5 IP66 Weight DB & DBP.5 kg (alloy), 8. kg (stainless) DB H & DBHP 5.6 kg (alloy),. kg (stainless) Enclosure material Stainless Steel or corrosion resistant alloy, ABS flare Finish Epoxy paint finish as standard or to customer s specification Entries up to x 0 mm or 5 mm ISO Rated terminal cross section up to 4 mm ) Sound level is dependent upon the tone selection 5.5 COOPER CROUSE-HINDS GMBH

115 I Ex- db(a) sounder I Ordering details DB Catalogue No. Certification Description Ordering Code DBBA04AANNNR ATEX approved Ex II GD 0 db(a), 4 V DC, x M0 entries, choice of 6 tones, red body finish PX 8000 DBHPULA04DDNNNR UL Listed, Class I, Div, Up to 0dB(A) at 0ft., two-stage alarms, with 6 tones, PX 865 Groups C & D 4 V DC, alloy, red body finish, no tag or duty labels, x /4" NPT entries DBPULA04DDNNNR UL Listed, Class I, Div, Up to 6dB(A) at 0ft., two-stage alarms, with 6 tones, PX 86 Groups C & D 4 V DC, alloy, red body finish, no tag or duty labels, x /4" NPT entries DBPULA0CCNNNR UL Listed, Class I, Div, Up to 6 db(a) at 0ft., sounder, 0 V AC, PX 0008 Groups C & D x /" NPT entries, red body finish 4 5 Ordering options* Unit Certifi- Code Material Code Voltage Code Entries ) Code Duty Code Tag label Code Features Code Finish Code Type cation label DB ATEX/CENELEX B SS 6 S V DC 0 0 mm A None N Required T Not required N Red R DB H UL Alloy A 4 V DC 04 5 mm B RequiredD Not Telephone Grey G DB P (DBIP & IHP only) UL 48 V DC 048 / NPT required N initiate T Special DB P GOST R 0 V DC 0 (UL only) C Relay initiate R finish S DB HP (DBI & DBIP only) G 40 V DC 40 /4 NPT Remote S (UL only) D End of line LHS resistor E ) RHS Bottom ) UL Available Alloy only ) Features not available on DBP and DB HP * For more options see or contact your local representative 6 8 Dimension drawing holes Ø fix. CRS 40 fix. CRS 80 Ø (6) 0.5 (5) 0 Ø0 Dimensions in mm COOPER CROUSE-HINDS GMBH 5.5

116 I Ex-8 db(a) sounder I DB DB with exlink Technical data DB Marking to 4//EC II G/D Ex d IIC T ) II G Ex de IIC T ) EC-Type Examination Certificate Type DB /DB 4 Ex d IIC Baseefa 00 ATEX 0X Type DB /DB 4 Ex de IIC Baseefa 00 ATEX 08X UL Listed for USA and Canada Class I, Div., Groups A-D Class I, Zones &, AExd IIC T4 Listing No. E00 GOST R Certification Ex d IIC T4 & Exde IIC T4 Russian Fire Alarm (VNIIPO) Approved GOST K Certification Ex d IIC T4 Chinese (CQST) Certification Ex d IIC T4 Enclosure material Body and horn glass reinforced polyester Swivel bracket stainless steel Finish Epoxy paint finish as standard or to customer s specification Max. sound levels Long flare = 5 ± db(a) (tone dependent) Short flare = 08 ± db(a) (tone dependent) Rated voltage and Rated current V DC ma 4 V DC 80 ma 48 V DC 0 ma 0 V AC 5 ma 0 V AC 4 ma 0 V AC 68 ma 0 V AC 65 ma 40 V AC 6 ma 54 V AC 5 ma Entries up to x 0 mm up to x / NPT Weight Ex d IIC: 6.0 kg Ex de IIC: 6.5 kg Rated terminal cross section 4 x.5 mm (AC) 6 x.5 mm (DC) Protection category to EN 5 IP66 and IP6 Permissible ambient temperature Ex d Ex de DB & DBP -0 C to +0 C (T4) -0 C to +45 C (T5/T00 C) DB L & DBLP -55 C to +55 C (T5) -55 C to +0 C (T4/T5 C) UL GOST R (Ex d) DB & DBP -55 C to +0 C -0 C to +50 C DB L & DBLP n/a -55 C to +55 C GOST R (Ex de) CQST DB & DBP -0 C to +40 C -0 C to +55 C DB L & DBLP -55 C to +55 C n/a ) depends on ambient temperature 5.54 COOPER CROUSE-HINDS GMBH

117 I Ex-8 db(a) sounder I Ordering details DB with exlink DB Catalogue No. Certification Description Ordering Code DBD048NBNRZ ATEX Ex II GD tones, no tag or duty labels, -48 V DC, x M0 entries PX 80 with one certified plug fitted, red finish DBPD048NBNNZ ATEX Ex II GD tones, no tag or duty labels, -48 V DC, x M0 entries PX 80 with one certified plug fitted, black finish DBD40NBNNZ ATEX Ex II GD tones, no tag or duty labels, 40 V AC, x M0 entries PX 80 with one certified plug fitted, black finish DBD40NBNRZ ATEX Ex II GD tones, no tag or duty labels, 40 V AC, x M0 entries PX 804 with one certified plug fitted, red finish DBPUL048NCNRZ UL, cul Listed, Class I, tones, two stage, no tag or duty labels, 08 db(a) output, PX 86 Div, Groups A, B, C, D NEMA 4X & 6, -48 V DC, x /" NPT entries with certified plug, red finish DBUL048NCNRZ UL, cul Listed, Class I, tones, no tag or duty labels, 08 db(a) output, PX 86 Div, Groups A, B, C, D NEMA 4X & 6, -48 V DC, x /" NPT entries with certified plug, red finish DBUL0NCNRZ UL, cul Listed, Class I, tones, no tag or duty labels, 08 db(a) output, PX 865 Div, Groups A, B, C, D NEMA 4X & 6, 0 V AC, x /" NPT entries with certified plug, red finish Ordering options* Unit Type Details Certification Code Voltage Code Label Code Entries Code Features Code Finish Code DB Standard unit Ex d D - 48 V DC 048 Duty D x 0 mm Not required N Natural DB P Two stage (DC only) Ex de E 0 V AC 0 Tag T (Ex d) B End of line Black N DB L* Low temp. standard unit UL Listed UL 0 V AC 0 None N x 0 mm resistor E Red R DB LP* Low temp. two stage ATEX/UL 0 V AC 0 (Ex d/ex de) B Special tone S Special (DC only) Dual Listed AU 0 V AC 0 x / NPT finish S ) GOST R Exd DG 40 V AC 40 (UL only) C GOST R Exde EG 54 V AC 54 x / NPT GOST K Exd DK (UL only) C Chinese (CQST) Q ) Customer to specify * For more options see or contact your local representative Dimension drawing 8 O,5 6 O 0,5 0 0,5 0 Dimensions in mm COOPER CROUSE-HINDS GMBH 5.55

118 I Ex-0 db(a) voice sounder I DB V Technical data DB V Marking to 4//EC II G/D Ex d IIC T ) II G Ex de IIC T ) EC-Type Examination Certificate Type DB /DB 4 Ex d IIC Baseefa 00 ATEX 0X Type DB /DB 4 Ex de IIC Baseefa 00 ATEX 08X GOST R Certification Ex d IIC T4 & Ex de IIC T4 Russian Fire Alarm (VNIIPO) Approved GOST K Certification Ex d IIC T4 Chinese (CQST) Certification Ex d IIC T4 Permissible ambient temperature ) Ex d Ex de DB V -0 C to +0 C (T4) -0 C to +45 C (T5/T00 C) DB LV -55 C to +55 C (T5) -55 C to +0 C (T4/T5 C) GOST R & K Exd GOST R Exde DB V -0 C to +55 C -0 C to +40 C DB LV -55 C to +55 C -55 C to +55 C Chinese Exd DB V -0 C to +55 C DB LV n/a Rated voltage and Rated current V DC 00 ma 4 V DC 0 ma 48 V DC 00 ma Rated terminal cross section 6 x.5 mm (DC) Voice recording up to 0 sec. Max. sound levels = 0 ± db(a) (tone dependant) (controlled by potentiometer) Protection category to EN 5 IP66 and IP6 Entries up to x 0 mm Weight 6.0 kg Enclosure material Body and horn glass reinforced polyester Swivel bracket stainless steel Finish Epoxy paint finish as standard or to customer s specification 5.56 COOPER CROUSE-HINDS GMBH

119 I Ex-0 db(a) voice sounder I Ordering options* DB V Unit Type Details Certification Code Label Code Entries Code Finish Code DB V Voice unit ATEX Ex d D Duty D ) x 0 mm (Ex d) B Natural Black N DB LV ) Low temp. voice unit ATEX Ex de E Tag T ) x 0 mm (Ex d/ex de) B Red R GOST R DG End of resistor E ) Special finish S 4) GOST K DK Message M Chinese Bell tone O (CQST) Q None N ) Available unpainted only ) Please specify wording ) _ state value 4) Please specify * For more options see or contact your local representative 4 5 Dimension drawing 6 6 O,5 O 0,5 0 8,5 0 0 COOPER CROUSE-HINDS GMBH 5.5 Dimensions in mm

120 I Ex-0 db(a) sounder I DB 5 Technical data DB 5 Marking to 4//EC II G Ex ia IIC T4 EC-Type Examination Certificate Baseefa 00 ATEX 5 HSE(M) to EN5004, EN5000 and EN500 Ex ia Cert. No. MECS0ATEX4 (unit) and 4Y05 (system) FM Approved Class I, Div. groups A, B, C, and D. J.I CSA to C. Nos. 0, 0.4, 0.5, 5, 0, 05 Class, Groups A, B, C and D Permissible ambient temperature -0 C to +55 C Rated voltage and Rated current DB5B0NR V DC ma DB5B04NR 4 V DC 4 ma Max. sound levels 00 ± db(a) (tone dependant) Rated terminal cross section 6 x.5 mm (DC) Protection category to EN 5 IP65 Entries up to x mm each side or x mm rear Weight 0. kg Enclosure material Acrylonitrile butadiene styrene Finish Red as standard Ordering details Catalogue No. Certification Description Ordering Code DB5B0NR ATEX Approved Ex II G Intrinsically safe, 6 tones, db(a) output, V DC, PX up to x M0 entries via knockouts, no labels, natural red finish DB5B04NR ATEX Approved Ex II G Intrinsically safe, up to x M0 entries via knockouts, 4 V DC PX up to x M0 entries via knockouts, no labels, natural red finish DB5FM04NR FM Approved for Class I, Intrinsically safe, 6 tones, db(a) output, PX 8650 Div &, no tag or duty labels, 4 V DC, x /6" entries Groups A, B, C, D via knockouts, natural red finish Ordering options* Unit Type Certification Code Voltage Code Label Code Finish Code DB 5 BASEEFA GP ( V only) M V 0 None N Red R BASEEFA GP B 4 V 04 Yes Y Special finish S ) FM FM ) Please specify * For more options see or contact your local representative Dimension drawing Dimensions in mm 5.58 COOPER CROUSE-HINDS GMBH

121 I Ex-8 db(a) sounder I Technical data DB DB Marking to 4//EC II G Ex ia IIB T4 II G Ex ia IIC T4 EC-Type Examination Certificate Baseefa 00 ATEX GOST R Certification 0Exia IIC T4, 0Exia IIB T4 Permissible ambient temperature -55 C to +0 C Rated voltage and Rated current V DC 5 ma to 55 ma 4 V DC 4 ma to 68 ma Rated terminal cross section 8 x.5 mm Max. sound levels V/4 V IIB 0 ± db(a) at metre V/4 V IIC 0 ± db(a) at metre Protection category to EN 5 IP65 Entries up to x M0 Weight.0 kg Enclosure material Glass reinforced polyester Finish Self coloured red as standard or epoxy coated to customer s specification Ordering details Catalogue No. Certification Description Ordering Code DBPBB04NR ATEX Approved Ex II G, 0 db(a) output, GRP, 4 V DC, up to x M0 entries PX Exia, IIB & IIC, T4 via knockouts, no labels, choice of 6 tones, natural red Ordering options* Unit Type Certification Code Voltage Code Label Code Finish Code DB P ATEX IIB BB V 0 Duty D ) Red N ATEX IIC BC 4 V 04 Tag T ) Special finish S GOST R IIB GB None N GOST R IIC GC ) Please specify * For more options see or contact your local representative Dimension drawing 8 Entry A O 0 Entry B Entry C COOPER CROUSE-HINDS GMBH 5.5 Dimensions in mm

122 E X - S P E A K E R S Explosion protected units for Zone 0,,,, Class I, Div, GOST This range of loudspeakers, intended for use in potentially explosive gas and dust atmospheres, can here a power rating of up to 0 watts and is suitable for use in all gas groups including hydrogen. The flamepaths, are and the body, are manufactured completely from a UV stable glass rein forced polyester. Stainless steel screws and sinter are incorporated thus ensuring a corrosion free product. A tapered flamepath is used to overcome the problems of assembly of parallel spigot flamepaths. An optional Ex-e terminal chamber is available on some units. An uncertified version is available for use in non-explosive atmospheres. Models compliant to BS 58, part 8 are available. UL listed for USA and Canada: Class I, Div, Groups A-D Class I, Zones &, AEcd IIC, T4 GOST R & K certified. Australian (SAA) certified. Optional Ex-e terminal chamber IP66 and IP6 Certified temperature -55 C to +0 C GRP corrosion-free flamepaths Up to dba at 0 watts at metre BS 58, part 8 compliant versions available Addressable capability Power tappings, via integral transformer Ratcheted swivel bracket Stainless steel sinter Stainless steel mounting bracket 5.

123 I Ex-8/5 watt speaker I Technical data DB 0 LF DB 0 SF DB 0 Marking to 4//EC II G Ex d IIB +H T ) EC-Type Examination Certificate BAS 0 ATEX 086X GOST R Certification Exde IIB + H T4/T5/T6 GOST K Certification Exde IIB + H T4/T5/T6 Chinese (CQST) Certification Exde IIB + H T4/T5/T6 Permissible ambient temperature ) T6: 55 C to +40 C T5: 55 C to +55 C T4: 55 C to +0 C Rated power 8 or 5 W RMS continuous at +5 C Rated terminal cross section 8 x.5 mm or 4 x.5 mm Output long flare (5 W) maximum output at W/ m at khz is 05 dba maximum output at 5 W/ m at khz is 5 dba short flare (8 W) maximum output at W/ m at khz is 8 dba maximum output at 8 W/ m at khz is 0 dba Frequency range 400 Hz to 8 khz Voice coil impedance 8 Ω Transformer 00 V line as standard Protection category to EN 5 IP66/IP6 Entries x M0 Ex d/ x M0 ISO Ex e Weight 5 W.0 kg / 8 W.5 kg Enclosure material Anti-static, UV stable, glass reinforced polyester, mounting stirrup and fixtures in stainless steel Finish All natural or body and horn can be painted to client s requirements Ordering details Type Description Ordering Code DB0B8XNBPN 8 Watt (short flare), 00 V transformer, x M0 entries with certified plug fitted, natural black PX 8008 DB0B5XNBPN 5 Watt (short flare), 00 V transformer, x M0 entries with certified plug fitted, natural black PX Ordering options* Unit Type Certification Code max. rated Power Code Transformer Code Options Code Entries Code Colour Code DB 0 ) ATEX B 8 W 8 Yes X ) Duty D x M0 B Natural black N GOST R R 5 W 5 8 Ω version N Tag T x M0 B Red R GOST K K None N x M0 entries BP ) Special S Chinese (CQST) Q ) For more options see or contact your local representative. ) Std. 00 V, other values are available ) With one certified plug fitted. Dimension drawing 0 O 6 45 O 6 O W Version O 0 Dimensions in mm COOPER CROUSE-HINDS GMBH 5.6

124 I Ex-8/5 watt speaker I DB 4 DB 4L Technical data DB 4 DB 4L Marking to 4//EC II G/D Ex d IIC T4 T5 C EC-Type Examination Ex d BAS 00 ATEX 0X Certificate Ex ed BAS 00 ATEX 08X UL listed for USA and Canada Class I, Div, Groups A-D Class I, Zones &, AExd IIC T4 GOST R Certification Exd IIC T4 & Exde IIC T4 Russian Fire Alarm (VNIIPO) approved GOST K Certification Exd IIC T4 Permissible ambient temperature DB 4 5 W -0 C to +0 C DB 4 > 5 W -0 C to +55 C DB 4L 5 W -55 C to +0 C DB 4L > 5 W -55 C to +55 C Rated power 8 W, 5 W, 0 W or 5 W RMS continuous at +5 C Rated terminal cross section 8 x.5 mm Frequency range 400 Hz to 8 khz Voice coil impedance 8 Ω Transformer 00 V line as standard Protection category to EN 5 IP66/IP6 Entries max. x M0 Ex d/ x M0 into Ex e chamber Weight Ex d 5.0 kg, depends on model Ex de +0.5 kg Enclosure material Anti-static, UV stable, glass reinforced polyester; swivel bracket in stainless steel; captive cover screws in stainless steel Finish All natural or body and horn can be painted to client s requirements Output long flare (>8 W) maximum output at W/ m is 0 dba maximum output at 5 W/ m is dba short flare (8 W) maximum output at W/ m is 00 dba maximum output at 8 W/ m is 0 dba 5.6 COOPER CROUSE-HINDS GMBH

125 I Ex-8/5 watt speaker I Ordering details DB 4 DB 4L Catalogue No. Certification Description Ordering Code DB45DXNBNZ ATEX Approved Ex II G 5 watt 00 V line transformer, no labels, x M0, PX 8045 one certified plug, flameproof enclosure, natural black finish DB45DXNBNZ ATEX Approved Ex II G 5 watt 00 V line transformer, no labels, x M0, PX 8045 one certified plug, flameproof enclosure, natural black finish DB45ULNTCRZ UL, cul Listed Class I, 5 watt high-output version, direct connection 8 Ohm, PX 8645 Div, Groups A, B, C, D Label = ABS Approved, x /" NPT entries, red finish DB45ULXNCR UL, cul Listed Class I, 5 watt 00 V line transformer, no labels, x /" NPT entries, PX 864 Div, Groups A, B, C, D red finish DB45ULXNCR UL, cul Listed Class I, 5 watt 0 V line transformer, no labels, x /" NPT entries, PX 8644 Div, Groups A, B, C, D red finish 4 5 Ordering options* Unit Type max. rated Code Certification Code Transformer Code Options Code Entries Code Colour Code Power DB 4 8 W 8 Ex d D Yes X ) Duty D x M0 Ex d B Natural Black N DB 4L 5 W 5 Ex de E 8 Ω version N Tag T x M0 Ex d/ Red R 0 W 0 UL listed UL Earth continuity E Ex e B Special S ) 5 W 5 Exd BS 58 part 8 D8 None N GOST R Exd GD GOST R Exde GE GOST K Exd KD ) Std. 00 V, other values are available ) Please specify * For more options see or contact your local representative Dimension drawing 6 8,5 0 O 0 5 6,5 0 0 O,5 O 6, Dimensions in mm COOPER CROUSE-HINDS GMBH 5.6

126 I Ex-5/0 watt speaker I DB 6 Technical data DB 6 Marking to 4//EC Ex IIB II G Ex de IIB T Ex IIC II G/D Ex de IIC T4 T0 C IP6X EC-Type Examination Ex IIB Baseefa 04 ATEX 06X Certificate Ex IIC Baseefa 04 ATEX 066X UL Listed for USA and Canada Class I, Div, Groups C & D Class I, Zone AExde IIB T Class I, Div, Groups A-D Class I, Zone AExde IIC T0 C GOST K Certification Exde IIC T4/IIB T Permissible ambient temperature 0 W version -50 C to +40 C 5 W version -50 C to +65 C Rated power 0 W RMS continuous at +5 C Frequency range 0 Hz to 8 khz Voice coil impedance 8 Ω Transformer 00 V line as standard Protection category to EN 5 IP66/IP6 Entries max. x M0/ x M5 into Ex e chamber Weight 5.5 kg approx. Enclosure material Body & horn in anti-static, UV stable, glass reinforced polyester Mounting stirrup and fixtures in stainless steel Finish All natural or body and horn can be painted to client s requirements Output IIB version maximum output at W/ m is dba maximum output at 5 W/ m is dba maximum output at 0 W/ m is dba IIC version maximum output at W/ m is 0 dba maximum output at 5 W/ m is 8 dba maximum output at 0 W/ m is dba Rated terminal cross section 8 x.5 mm 5.64 COOPER CROUSE-HINDS GMBH

127 I Ex-5/0 watt speaker I Ordering details DB 6 Catalogue No. Certification Description Ordering Code DB6UCXNMPN UL, cul Listed, Class I, Unit suitable for gas Groups A, B, C, D, 0V line transformer, PX Div, Groups C & D x /" NPT, one certified plug, natural black finish Ordering options* 4 Unit Type Certification Code max. rated Code Transformer Code Options Code Entries Code Colour Code Power DB 6 ATEX IIB BB 5 W 5 Yes X ) Duty D x M0 B 4) Natural black N ATEX IIC BC 0 W 0 8 Ω version N Tag T x M0 B 4) Red R UL (C & D)) UB Earth continuity E x M5 C 4) Special S 5) UL (A-D)) UC Earth stud B x M5 C 4) GOST K IIB KB None N GOST K IIC KC ) Suitable for gas groups C & D ) Suitable for gas groups A D ) Std. 00 V, other values are available 5 6 4) To specify certified plug, suffix appropriate code with P 5) Please specify * For more options see or contact your local representative Dimension drawing 54,5 O 4 O , ,5 0 0 COOPER CROUSE-HINDS GMBH 5.65 Dimensions in mm

128 I Ex-5 watt speaker I DB 8 Technical data DB 8 Marking to 4//EC II G/D Ex na II T5 C Compliance CENELEC EN 5004, EN 500 Permissible ambient temperature -55 C to +55 C Rated power 5 W RMS continuous at +5 C Rated terminal cross section 8 x.5 mm Frequency range 400 Hz to khz Voice coil impedance 8 Ω Transformer 00 V line as standard Protection category to EN 5 IP66/IP6 Entries max. x M0 Ex d/ x M0 into Ex e chamber Weight.6 kg Enclosure material Anti-static, UV stable, glass reinforced polyester; swivel bracket in stainless steel; captive cover screws in stainless steel Finish All natural or body and horn can be painted to client s requirements Output maximum output at W/ m at 00 Hz is 0 dba maximum output at 5 W/ m at 00 Hz is dba Ordering details Catalogue No. Certification Description Ordering Code DB8XNN ATEX approved Ex II G/D 5 Watt, 00 V line transformer, x M0 entries, natural black finish PX Ordering options* Unit Type Transformer Code Options Code Entries Code Colour Code DB 8 Yes X ) Duty D x M0 Ex d B Natural black N Transf. and 8 Ω terminals X8 Tag T x M0 Ex d/ex e B Red R 8 Ω version N Earth continuity E Special S ) Blanking plug P None N ) Std. 00 V, other values are available ) Please specify * For more options see or contact your local representative Dimension drawing 0 O 6 O Dimensions in mm 5.66 COOPER CROUSE-HINDS GMBH

129 I Ex-5 watt projector speaker I Technical data DB DB Marking to 4//EC II G/D Ex na II T5 C Compliance CENELEC EN 5004, EN 500 Permissible ambient temperature -55 C to +55 C Rated power 5 W RMS continuous at +5 C Frequency range 0 Hz to 0 khz Voice coil impedance.5 k,. k,. k,.5 k,. kω, 666 Ω Transformer 00 V line as standard Protection category to EN 5 IP54 Entries M0 gland Weight.6 kg Enclosure material Body in aluminium Mounting stirrup and fixtures in stainless steel Finish Powder coated white to RAL 00 as standard can be painted to clients requirements Output maximum output at W/ m at 00 Hz is dba maximum output at 5 W/ m at 00 Hz is 04 dba Rated terminal cross section 4 x.5 mm Ordering details Catalogue No. Certification Description Ordering Code DBXNN ATEX approved Ex II G/D 5 Watt, 00 V line transformer, white to RAL 00 PX Ordering options* Unit Type Transformer Code Colour Code DB Yes X ) Natural black N 8 Ω version N Red R Special S ) ) Std. 00 V, other values are available ) Please specify * For more options see or contact your local representative 8 Dimension drawing Ø Dimensions in mm COOPER CROUSE-HINDS GMBH 5.6

130 E X - H E A T D E T E C T O R Explosion protected units for Zone 0,, and The MEDC-Hawco heat detector has been designed for use in hazardous environments. These units are suitable for fire alarm and/or suppression systems in offshore and onshore applications including paint spray booths, flammable material stores, turbine rooms, extract ductwork and other hazardous areas throughout the oil & gas, petrochemical and process industries. Comprising a Fenwal ratecompensated detector with all-stainless steel external construction, mounted to either a type SM8 marine grade alloy enclosure (Ex d version) or JB0 corrosion-free GRP enclosure (Ex ia, Ex em/ul versions). The contact in the detector CLOSES at alarm temperature. UL listed for USA and Canada Class I, Div, Groups A-D GOST R & K certifi ed. Chinese (CQST) certifi ed. IP66 & IP6 Certifi ed temperature: 0 C to +5 C (Exd). 0 C to +55 C (Exem/UL). 55 C to +55 C (Exia) Stainless steel probe Detector temperature settings: C to 85 C, (40 F to 5 F)* Marine grade alloy or GRP enclosure Optional guard 5.68

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 1 EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 2 ouse se-hin inds 20 08 - all righ ghts re serv rved C ou Co oper Cr 3 4 5 6 7 EX-CEILING LIGHT FITTINGS 5.41 8 EX-PENDANT LIGHT FITTINGS EX-FLOODLIGHTS

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22) .5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS ellb 20... 1-5 W Metallic design for Zone 1 and 21 The ellb 20 explosion-protected ceiling light fitting with electronic ballast meet the requirements of ATEX-Directive

More information

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire

More information

Unused flameproof threads for cable glands have to be closed with certified plugs.

Unused flameproof threads for cable glands have to be closed with certified plugs. E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,

More information

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type

More information

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de

More information

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22) .15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , 1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection

More information

EX-D ENCLOSURES AND DISTRIBUTIONS

EX-D ENCLOSURES AND DISTRIBUTIONS EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated

More information

EV 35 LED Robust Ex-pendant light fitting series with efficient lighting technology

EV 35 LED Robust Ex-pendant light fitting series with efficient lighting technology LED technology for hazardous areas EV 35 LED Robust Ex-pendant light fitting series with efficient lighting technology LED Technology for Zone 1/2 and 21/22 The efficient solution for your illumination

More information

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps .4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected

More information

International approvals.

International approvals. E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

I Ex-Safety switches I

I Ex-Safety switches I 3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components E X - D D I S T R I B U T I O N S with metal EJ enclosures for gases in explosion group IIB Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Main current switches >180 A are realized in metal enclosures. Internationally approved. E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility

More information

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East

More information

Internationally approved.

Internationally approved. E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure

More information

Floodlight Series 6521/4

Floodlight Series 6521/4 > The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight

More information

EX-FLUORESCENT LIGHT FITTINGS

EX-FLUORESCENT LIGHT FITTINGS 1 EX-FLUORESCENT LIGHT FITTINGS 2 3 5 6 EX-LIGHT FITTING ellk 92... MAIN FEATURES EX-LIGHT FITTING ellk 92... 2.20 2.12 7 EX-POLE MOUNTED LIGHT FITTING ellm 92... EX-EMERGENCY LIGHT FITTING ellk 92...

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings.  EATON 1.3.1 CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de

More information

Linear fluorescent luminaire LED V-CG-S

Linear fluorescent luminaire LED V-CG-S (2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K

More information

I Ex-safety switches I

I Ex-safety switches I 3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99

More information

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/ d.o.o. tel. 049 222 900 fax. 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/ No: TEPEx.RS.028 Rev : 1 Date: 09.2014. SADRŽAJ 1. Manufacturer 1 2. General

More information

I Ex-control stations I

I Ex-control stations I Type 11 83 Type 11 82 Type 11 81 Technical data Ex-control stations Type 11 81 I Type 11 82 I Type 11 83 Marking accd. to 9/9/EC II 2 G Ex ed ib m IIC T6 II 2 D Ex td A21 IP66 T80 C EC-Type Examination

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - M A N U A L M O T O R S T A R T E R S Up to A Motors have to be protected against over loads, phase failures and overheating: CEAG's power circuit breaker and manual motor starter features phase-failure

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

EX-FLUORESCENT LIGHT FITTINGS

EX-FLUORESCENT LIGHT FITTINGS 1 EX-FLUORESCENT LIGHT FITTINGS 2 Co oper Cr ouse se-hinds 200 - all righ ghts rese serv rved EX-LIGHT FITTING ellk 2... MAIN FEATURES 2.20 3 4 6 7 EX-LIGHT FITTING ellk 2... EX-POLE MOUNTED LIGHT FITTING

More information

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22 Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights CEAG Products Explosion protected floodlights CROUSE-HINDS SERIES PXLED - Power Floodlight Series for Hazardous Areas Explosion-protected LED floodlight series for Zone 1, 2, 21 and 22 Ex-Floodlight PXLED

More information

Pendant Light Fitting IEC

Pendant Light Fitting IEC Pendant Light Fitting IEC Operating instructions Additional languages www.r-stahl.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - D D S T R B U T O N S with metal EJ enclosures for gases in explosion group B Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

ellk/m 92 LED 400/800

ellk/m 92 LED 400/800 Explosion-protected Linear LED Light Fitting for Zone 1 and 21 1.1 ellk/m 92 LED 400/800 Linear LED Ex-light fittings ellk/m 92 LED 400/800 / ellk 92 LED 400/800 CG-S/NIB (Zone 1, 2, 21, 22) The efficient

More information

ellk 92 LED Light Fittings

ellk 92 LED Light Fittings CEAG Products Ex-Solutions LED Lighting ellk 92 LED Light Fittings Linear light fitting series with new LED module for hazardous areas Zone 1, 2, 21 and 22 www.crouse-hinds.de EATON 1.2.1 Ex-LED-Linear

More information

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5

More information

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light .4 Ex-Searchlight series SEB 8.., SEB 9.. and SEB 0 (Zone, 2, 2, 22) Portable searchlights for harsh conditions The explosion-protected portable searchlight series SEB 8/9/0 provides a strong and reliable

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22 Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

Nightscape High performance floodlights and spotlights for discharge lamps

Nightscape High performance floodlights and spotlights for discharge lamps Nightscape High performance floodlights and spotlights for discharge lamps Nightscape is a range of floodlights and spotlights which offers new possibilities for the architectural illumination of buildings.

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVNL LED fitting - zones 2, & 22 65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress

More information

EWE. Ex de. Cooling fins

EWE. Ex de. Cooling fins EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

Leading the way in hazardous areas Features EATON

Leading the way in hazardous areas Features EATON .2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected

More information

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2 Features Wide or narrow beam Ex e integral junction box Flat or pole mounting Supplied with lamp installed Including accessories (cable gland & plug) Supplied with offshore grade paint Manufactured from

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Dust - an Explosive Risk

Dust - an Explosive Risk CEAG Products for Dust Ex-Applications Dust - an Explosive Risk Safe Solutions from Eaton's Crouse-Hinds Division One spark may be enough. What can happen in areas with dust? Dust explosions are more dangerous

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W /27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3

More information

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety 4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4

More information

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22 SLEE - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22 S u p p or t i n g br a c ket Hin ge for op en in g

More information

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008 Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency

More information

Sheet-Steel Light Fittings Series 6014 / 6414

Sheet-Steel Light Fittings Series 6014 / 6414 > As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive

More information

Easy and safe installation

Easy and safe installation ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

K: bracket type. L: pole type

K: bracket type. L: pole type Lighting Technology Catalogue number logic B0091-0 -0 0 0 Pendant Light Fittings BDD91 Series Explosion-proof Light Fittings Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

Compact Sheet-Steel Light Fittings Series 6114

Compact Sheet-Steel Light Fittings Series 6114 > As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in

More information

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover. E X - T E R M I N A L E N C L O S U R E S Stainless Steel Version for Zone and Zone 2 The enclosure range is an ATEX certified enclosure / termination solution for category 2 (Zone) application with an

More information

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 > For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can

More information

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVDL LED fitting - zones 21, & 22 ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield

More information

EWE. Cooling fins. Ex de

EWE. Cooling fins. Ex de EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4

More information

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVTL Weatherproof LED fitting - Industrial applications 89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted

More information

I Ex-e/Ex-i terminal box I

I Ex-e/Ex-i terminal box I ID TAG label & bracket Door document holder opti. Security padlock Hasp opti. Technical data Marking accd. to 94/9/EC II G Ex e II / II D Ex td A1 IP66 Temperature class T6 up to +40 C / T5 up to +55 C

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information