J: Emergency lighting (optional) L: pole type X: ceiling type Mounting
|
|
- Edith Burke
- 5 years ago
- Views:
Transcription
1 Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone 1 and Zone Class I, Zone 1 and Zone Class I, Division, Groups A, B, C, D Two enclosure types: 18W, 36W. Enclosure in glass fibre reinforced polyester, diffuser in polycarbonate, corrosion-proof. Ex e enclosure with explosion-proof components inside. Safety interlock between enclosure and diffuser switches off on opening. Electronic ballast, power factor.9. Emergency unit with protections against over charge and over discharge. End of lamp life (EOL) rectification effect protection. Catalogue number logic BAY1-Q x J: Emergency lighting (optional) L: pole type X: ceiling type Mounting B: wall type D: pendant chain type G: pendant pole type Lamp number Lamp power (W) Explosion-proof light fittings for fluorescent lamp Zones 1&; 1& / General Catalogue
2 Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Technical data Explosion-proof light fittings for fluorescent lamp BAY1-Q x Explosion protection Gas explosion protection Dust explosion protection Certificates Conformity to standards Material Enclosure Diffuser Ballast Exposed fastener Interlock Lamp Lamp brand Lamp power (W) II G Ex deq IIC T4 Gb II D Ex t IIIC T8 Db IP66 LCIE 1 ATEX 34X; IECEx CQM 7.7 BR977 (Brazil); S-XPL/447 (South Africa); FM (USA); GOST.R (Russia) EN 679-:9, EN 679-1:7, EN 679-:7, EN 679-7:7 EN :9 IEC 679-:7, IEC 679-1:7, IEC 679-:7, IEC 679-7:6 IEC :8 GRP, stands 7J impact, corrosion-proof Polycarbonate, 9% light transmission, stands 7J impact Explosion-proof electronic ballast, power factor.9, with protection against short circuit, overload, lamp aging, lamp damage and dissymmetry power of lamp tube. Certificate No.: LCIE 6 ATEX 3U; IECEx CQM 7.U; BR976-U (Brazil). Stainless steel BZX-6 explosion-proof distance switch, switching off on opening. Certificate No.: LCIE 6 ATEX U, IECEx CQM 7.6U PHILIPS T8 (supplied with the light fittings) 36W x 18W x 36W x 1 18W x 1 Rated voltage Protection class Degree of protection Ambient temperature Terminal Cable entries Available cable outer diameter 96~4V AC /6Hz II (Protection against electric shock) IP66 - ~+ 3 x 1.~4mm (L+N+PE) 4 x Φ6: x M x 1. cable gland (DQM-I Ex e, plastic), x M x 1. plug. Φ9~Φ16 (mm) Selection table Type/Ordering code Lamp power(w) Weight(kg) Type/Ordering code Lamp power(w) Weight(kg) BAY1-QL 11.4 BAY1-Q36 x L 36 x 11.6 BAY1-QX 11.3 BAY1-Q36 x X 36 x 11.4 BAY1-QB 1.3 BAY1-Q36 x B 36 x 1. BAY1-QD 1.6 BAY1-Q36 x D 36 x 1.7 BAY1-QG 1. BAY1-Q36 x G 36 x 1.4 BAY1-QL 6.8 BAY1-Q18 x L 18 x 7. BAY1-QX 6.7 BAY1-Q18 x X 18 x 6.9 BAY1-QB 7.8 BAY1-Q18 x B 18 x 7.9 BAY1-QD 8.1 BAY1-Q18 x D 18 x 8. BAY1-QG 7.7 BAY1-Q18 x G 18 x 7.8 Note: Products above include all the mounting accessories listed in Mounting Accessories & Spare Parts Table (see P/6~7). General Catalogue /3
3 Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Technical data Explosion-proof emergency light fittings for fluorescent lamp BAY1-Q x J Explosion protection Gas explosion protection Dust explosion protection Certificates Conformity to standards Material Enclosure Diffuser Emergency unit Emergency controller Exposed fastener Lamp Lamp brand Lamp power(w) Emergency power(w) Emergency start time Charge time Emergency lighting time Rated voltage Protection class Degree of protection Ambient temperature Terminal Cable entries Available cable outer diameter II G Ex deq IIC T4 Gb II D Ex tb IIIC T8 Db IP66 LCIE 1 ATEX 39; IECEx CQM 1.X; BVC 1.3 (Brazil); FM (USA) GOST.R (Russia) EN 679-: 9, EN 679-1: 7, EN 679-: 7, EN 679-7: 7 EN : 9 IEC 679-: 11, IEC 679-1: 7, IEC 679-: 7, IEC 679-7: 6 IEC : 8 GRP, stands 7J impact, corrosion-proof Polycarbonate, 9% light transmission, stands 7J impact Special emergency controller and NI-MH battery pile, with protection against over charge and over discharge BY- explosion-proof emergency controller. Certificate No.: LCIE 1 ATEX 31U, IECEx CQM 11.41U Stainless steel PHILIPS T8 (supplied with the light fittings) 36W x 36W x 1 36W x 1, 18W x 1.3s 4h 1min (18min is optional) 96~4V AC /6Hz II (Protection against electric shock) IP66 - ~+ 3 x 1.~4mm (L+N+PE) 4 x Φ6: x M x 1. cable gland (DQM-I Ex e, plastic), x M x 1. plug. Φ9~Φ16 (mm) 18W x 18W x 1 Selection table Type/Ordering code Lamp power(w) Weight(kg) Type/Ordering code Lamp power(w) Weight(kg) BAY1-QLJ 13. BAY1-Q36 x LJ 36 x 13. BAY1-QXJ 1.9 BAY1-Q36 x XJ 36 x 13.1 BAY1-QBJ 14. BAY1-Q36 x BJ 36 x 14.1 BAY1-QDJ 14.3 BAY1-Q36 x DJ 36 x 14.4 BAY1-QGJ 13.9 BAY1-Q36 x GJ 36 x 14. BAY1-QLJ 8.6 BAY1-Q18 x LJ 18 x 8.8 BAY1-QXJ 8. BAY1-Q18 x XJ 18 x 8.7 BAY1-QBJ 9.6 BAY1-Q18 x BJ 18 x 9.7 BAY1-QDJ 9.9 BAY1-Q18 x DJ 18 x 1. BAY1-QGJ 9. BAY1-Q18 x GJ 18 x 9.6 Note: Products above include all the mounting accessories listed in Mounting Accessories & Spare Parts Table (see P/6~7). /4 General Catalogue
4 Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Photometric data 18W x photometric data Rated luminous flux:1lm; The data from PHILIPS lamp; Luminous intensity distribution cd/1lm 36W x photometric data Rated luminous flux:lm; The data from PHILIPS lamp; Luminous intensity distribution cd/1lm W x 1 fluorescent lamp*. 36W x 1 fluorescent lamp*. We can provide lighting design and data by professional lighting software DIALUX based upon simulated site situation on request. Schematic diagram (BAY1-Q x J) 1 1 Note: Tube for lamp shall be default for single tube fittings. Dimension drawings (all dimensions in mm) - subject to alteration BAY1-Q36 x BAY1-Q18 x General Catalogue /
5 Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Mounting type (all dimensions in mm) - subject to alteration Installation reference D: pendant chain type G: pendant pole type 6-Φ1. -Φ84 4-Φ L: pole type (the pole is provided by user) Φ4 7 8 Φ4 7 6 Φ4 7 6 Φ48 4-Φ14 Φ48 Φ48 Suitable for ground pole type Suitable for fence pole type Suitable for wall pole type X: ceiling type B: wall type 4-Φ Φ11 Mounting accessories and spare parts table Supplied according to the mounting type Mounting Accessories Ordering Weight type Name Qty Illustration code (kg) 3-Φ1. 1.Sucker D: pendant chain type Φ84.Chain Length: 4mm Mounting bracket Same as pendant pole type Mounting bracket Φ8. 1S1G1.4 -Φ1 G: pendant pole type 4.M8 Screw Length: 3mm 1S1G.1.Mounting bracket Φ Φ1 Note: Accessories not in the table shall be supplied by user. /6 General Catalogue
6 Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Mounting accessories and spare parts table Supplied according to the mounting type Mounting Accessories type Name Qty Illustration Ordering code Weight (kg) 6.Mounting bracket Φ7 L: pole type 7.G1 1/4 Pipe clamp Mounting bracket Same as pendant pole type X: ceiling type 9.Mounting bracket B: wall type 1.Wall bracket Welded sheet steel 136B.6 Note: Accessories not in the table shall be supplied by user. Accessories Picture Name Ordering code Weight (kg) Explosion-proof distance switch Spanner Lamp holder (with wires) W Explosion-proof electronic ballast W Explosion-proof electronic ballast W Explosion-proof emergency controller (with battery) W Explosion-proof emergency controller (with battery) General Catalogue /7
L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L
Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:
More informationK: bracket type. L: pole type
Lighting Technology Catalogue number logic B0091-0 -0 0 0 Pendant Light Fittings BDD91 Series Explosion-proof Light Fittings Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationEmergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
> As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationLoad disconnect switch Series 8146/5-V11
www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationSheet-Steel Light Fittings Series 6014 / 6414
> As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive
More informationLinear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationLinear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More informationTubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22
Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More information7 Lighting Technology
7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources
More informationEmergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
> For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationEXEL-L. Detail of the internal side. Transparent polycarbonate
EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected
More informationLinear fittings EVNL LED fitting - zones 2, & 22
65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More information4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)
4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full
More informationEasy and safe installation
ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield
More informationZone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108
Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationTubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22
Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More informationZone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008
Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency
More informationCompact Sheet-Steel Light Fittings Series 6114
> As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in
More information10 Load and Motor Switchgear
10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,
More informationEXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components
EXENC-L - Zone 2, Zone 21-22 - Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components Resin body reinforced polyester Fixing Brackets Transparent hood
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationLinear Luminaire for Fluorescent Lamps
Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding
More informationTubular Light Fitting with LED Series 6036
> Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to high power LEDs used including driver
More information110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W
/27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3
More informationSheet Steel Emergency Light Fitting Series 6018
> For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and
More informationControl Buttons / Switches for Panel Mounting Series 8003
www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More information7 Lighting Technology
7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting
More informationLinear fittings EVN Fluorescent fitting - zones 2 & 22
LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationFluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety
Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous
More informationWELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)
WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,
More informationATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationControl Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations
Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC
More informationAVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips
AVN - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C Transparent polycarbonate diffuser Stainless steel clips Polyamide cable gland and plug
More informationBattery Boxes Series 8316
www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge >
More informationI Ex-safety switches I
3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationEWE. Ex de. Cooling fins
EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22
Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against
More informationPower (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13
Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationZone 1 Linear Range - Installation Guide
Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text
More information11 Control Panels, Distribution Panels and Components
Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working
More information7 Lighting Technology
7 Lighting Technology Sheet-Steel Emergency Light Fitting 09361E00 and 6418 (Zones 2, 21 and 22) emergency light fittings in sheet-steel can be used for safety illumination, especially in spraying and
More informationTank Inspection Lights Series 6122
> For halogen lamps 5 W to 100 W > Mounting options tilting hinge mounting bracket flange collar > Corrosion-resistant light metal enclosure > Connection options potted connection lead connection www.stahl.de
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More informationI 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I
I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.