1 Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance costs Available in polycarbonate (light, high impact resistant) or in glass (specific chemical environment & paint shop) Including accessories (cable gland, plug & fixing brackets) Supplied with offshore grade paint Specifications Manufactured from marine grade aluminium alloy copper free UV protected polycarbonate tube - thickness.5mm or borosilicate glass - thickness 7mm Rated voltage Vac/Vdc 50/60Hz Wiring configuration: 3 wires 1xEntry M0 Emergency version (Type: EM version 3h battery duration) Certifications Standards Approved to: EN , , , EC Type examination Directive 94/9/EC certificate to: INERIS 11 ATEX 005X Ex II G Ex de IIC T6 Gb for -0 C to + 55 C (XFP10, XFP136, XFP140, XFP155, XFP165, XFP0, XFP36, XFP40, XFP55, XFP65) Ex de IIC T6 Gb for -0 C to + 55 C (XFP10V, XFP0V, XFP136V, XFP36V, XFP155V, XFP55V) Ex de IIB T6 Gb for -0 C to + 55 C (XFP140V, XFP165V, XFP40V and XFP65V) Ex II D Ex tb IIIC T80 C Db IP66 for -0 C to + 55 C Glow wire test: 960ºC EN Ambient -0 C to +55ºC XFP, temperature range: -10 C to +50ºC XFP EM IP test: IP66 IEC 6059 (001) Impact protection index: IK09 (poly) IK07 (glass) according to IEC 66 ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-140 UK 01/15 /19
2 165 Tubular fluorescent fitting with automatic switch off A 3 B 3 6 PEM 0 XFP Dimensional drawing Technical specifications Light Current External dimensions mm Type Wiring Configuration Rating W A 30V Diffuser A B Weight kg 3 wires: Polycarbonate Diffuser Equipped with 1 cable gland & 1 plug XFP10-0G000 3 wires 1 x Polycarbonate XFP136-0G000 3 wires 1 x PL36 0. Polycarbonate XFP140-0G000 3 wires 1 x Polycarbonate XFP155-0G000 * 3 wires 1 x PL Polycarbonate XFP165-0G000 3 wires 1 x Polycarbonate XFP0-0G000 3 wires x Polycarbonate XFP36-0G000 3 wires x PL Polycarbonate XFP40-0G000 3 wires x Polycarbonate XFP55-0G000 * 3 wires x PL Polycarbonate XFP65-0G000 3 wires x Polycarbonate wires: Glass Diffuser Equipped with 1 cable gland & 1 plug XFP10V-0G000 3 wires 1 x Glass XFP136V-0G000 3 wires 1 x PL36 0. Glass XFP140V-0G000 3 wires 1 x Glass XFP155V-0G000* 3 wires 1 x PL Glass XFP165V-0G000 3 wires 1 x Glass XFP0V-0G000 3 wires x Glass XFP36V-0G000 3 wires x PL Glass XFP40V-0G000 3 wires x Glass XFP55V-0G000* 3 wires x PL Glass XFP65V-0G000 3 wires x Glass * T5 for gas or T95 C for dust when supply is 40Vac Technical information Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G13, diameter 6mm - white industry 4000 K Compact PL lamp, lampholder G11. Photometric curve See page 6/10 Rated voltages Electronic ballast: Vac/Vdc, 50-60Hz. Power factor Terminal block (screws plug in terminal block) 6mm²(rigid wire), 4mm² (flexible wire) Terminals supplied L, N, PE Wiring Configuration 3 wires Cable entries One entry M0 Included: One M0 nickel plated brass cable gland for non armoured cable, diameter 10-16mm (EXN04MLC) Casting Marine grade aluminium alloy according to standard: EN 1706: EN AC-AlSi1 (Fe) DF or EN AC-AlSi 10Mg(A) DF UV protected extruded polycarbonate tube, thickness.5mm or borosilicate glass thickness 7mm Colour of casting (standard) l XFP****-0G000 - Yellow offshore, RAL 1003 Colour options: l XFP****-BG000 - Grey, RAL 7035 l XFP****-CG000 - Black, RAL 9004 l XFP****-DG000 - Hammered Blue, RAL 5015 l XFP****-FG000 - Red, RAL 3001 l XFP****-GG000 - Blue, RAL 5010 l XFP****-JG000 - Green, RAL 603 m XFP****-MG000 - White, RAL 9010 Fixing (included) D03 -x zinc plated steel articulated brackets for ceiling mounting (included with product) /0 ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-140 UK 01/15
3 Emergency tubular fluorescent fitting with automatic switch off - 3h XFP EM - Zones 1, & 1, Technical specifications Light Current External dimensions mm Type Wiring Configuration Rating W Battery h A 30V Diffuser A B Weight kg 3 wires: Polycarbonate Diffuser Equipped with 1 cable gland & 1 plug XFP10EM-0G000 3 wires 1 x 18 3h 0.15 Polycarbonate XFP140EM-0G000 3 wires 1 x 36 3h 0. Polycarbonate XFP165EM-0G000 3 wires 1 x 58 3h 0.35 Polycarbonate XFP0EM-0G000 3 wires x 18 3h 0.3 Polycarbonate XFP40EM-0G000 3 wires x 36 3h 0.4 Polycarbonate XFP65EM-0G000 3 wires x 58 3h 0.5 Polycarbonate wires: Glass Diffuser Equipped with 1 cable gland & 1 plug XFP10VEM-0G000 3 wires 1 x 18 3h 0.15 Glass XFP140VEM-0G000 3 wires 1 x 36 3h 0. Glass XFP165VEM-0G000 3 wires 1 x 58 3h 0.35 Glass XFP0VEM-0G000 3 wires x 18 3h 0.3 Glass XFP40VEM-0G000 3 wires x 36 3h 0.4 Glass XFP65VEM-0G000 3 wires x 58 3h 0.5 Glass Electrical Features Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G13, diameter 6mm - white industry 4000 K Compact PL lamp, lampholder G11. Photometric curve See page 6/10 Rated voltages Electronic ballast: 0-40Vac/Vdc 50/60Hz Power factor Battery Battery NiCd 7,V 4Ah in flameproof case (Ex d ) Lumen output in emergency mode (1 lamp lit) hours: 40% for XFP10, XFP0, 33% for XFP140, XFP40, 10% for XFP165, XFP65 3 hours: 4% for XFP10, XFP0, 18% for XFP140, XFP40, 8% for XFP165, XFP65 Monitored by one LED Terminal block (screws plug in terminal block) 6mm²(rigid wire), 4mm² (flexible wire) Terminals supplied L1,, N, PE. Wiring Configuration 3 wires Cable entries One entry M0 Included: One M0 nickel plated brass cable gland for non armoured cable, diameter 10-16mm (EXN04MLC) Casting Marine grade aluminium alloy according to standard: EN 1706: EN AC-AlSi1 (Fe) DF or EN AC-AlSi 10Mg(A) DF UV protected extruded polycarbonate tube, thickness.5mm or borosilicate glass thickness 7mm Colour of casting (standard) l XFP****-0G000 - Yellow offshore, RAL 1003 Colour options: l XFP****-BG000 - Grey, RAL 7035 l XFP****-CG000 - Black, RAL 9004 l XFP****-DG000 - Hammered Blue, RAL 5015 l XFP****-FG000 - Red, RAL 3001 l XFP****-GG000 - Blue, RAL 5010 l XFP****-JG000 - Green, RAL 603 m XFP****-MG000 - White, RAL 9010 Fixing (included) D03 - x zinc plated steel articulated brackets for ceiling mounting (included with product) Emergency function diagrams Wiring provided by DTS - Maintained Mode Switch between L/ - Non Maintained Mode * L L 1 0 Mains Supply Tube Battery ON Lit Charged OFF Only emergency tube lit Discharged Mains Supply Tube Battery ON OFF Charged OFF Only emergency tube lit Discharged * This table corresponds to the position 0 open. If the switch is on position 1 close, refer to the table on the left ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-140 UK 01/15 /1
4 Accessories Bi-pin T8 fluorescent lamps Specifications: G13 - ø 6mm Colour temperature: White industry 4000 K CRI: > 80 lm/w: 65to 93 Average operating life: 1,000 hours Type Power W Lumen output lm Lampholder TL18W G13 TL36W G13 TL58W G13 Compact fluorescent lamps Specifications: G11 Colour temperature: White industry 4000 K CRI: > 80 lm/w: 57 to 87 Average operating life: 0,000 hours Type Power W Lumen output lm Lampholder PL18W G11 PL36W G11 PL55W G11 Brackets R 55 Ø Ø8 Ø Hinged bracket D03 x zinc plated steel articulated brackets for ceiling mounting (included with product) D04 x stainless steel 304L articulated brackets for ceiling mounting Accessories U-bolt for pole mounting D05 x U-bolt and x zinc plated steel brackets for pole mounted 1 1/4 D06 x U-bolt and x zinc plated steel brackets for pole mounted 1 1/ D07 x U-bolt and x zinc plated steel brackets for pole mounted D09 x U-bolts and x stainless steel brackets (304L) for pole mounted 1 1/ D030 x U-bolts and x stainless steel brackets (304L) for pole mounted Shock proof kit D034 Stainless steel 304L canopy and shock proof kit for XFP10, XFP0 D035 Stainless steel 304L canopy and shock proof kit for XFP140, XFP40 D036 Stainless steel 304L canopy and shock proof kit for XFP165, XFP65 / ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-140 UK 01/15
5 Spare parts Spare parts Type D001P0WC D001P40WC D001P65WC D001PV0WC D001PV40WC D001PV65WC D0051X0WE D0051X0WEM D0051X36WE D0051X40WE D0051X40WEM D0051X55WE D0051X65WE D0051X65WEM D005X0WE D005X0WEM D005X36WE D005X40WE D005X40WEM D005X55WE D005X65WE D005X65WEM D010 D010PL D016 D01C D0 D003 4GRA0000S EXN04MLC-01 EXN04MMC1-01 Specifications Sealed polycarbonate tube, cover, gasket, chain and slides - Offshore grade yellow paint RAL XFP0, XFP10, XFP136, XFP36 Sealed polycarbonate tube, cover, gasket, chain and slides - Offshore grade yellow paint RAL XFP40, XFP140, XFP55, XFP155 Sealed polycarbonate tube, cover, gasket, chain and slides- Offshore grade yellow paint RAL XFP65, XFP165 Sealed glass tube, cover, gasket, chain and slides- Offshore grade yellow paint RAL XFP0, XFP10, XFP136, XFP36 Sealed glass tube, cover, gasket, chain and slides- Offshore grade yellow paint RAL XFP40, XFP140, XFP55, XFP155 Sealed glass tube, cover, gasket, chain and slides - Offshore grade yellow paint RAL XFP65, XFP165 Gear tray with electronic ballast V, Hz for XFP10 Emergency Gear tray with electronic ballast 0-40V, Hz for XFP10EM Gear tray with electronic ballast V, Hz for XFP136 Gear tray with electronic ballast V, Hz for XFP140 Emergency Gear tray with electronic ballast 0-40V, Hz for XFP140EM Gear tray with electronic ballast V, Hz for XFP155 Gear tray with electronic ballast V, Hz for XFP165 Emergency Gear tray with electronic ballast 0-40V, Hz for XFP165EM Gear tray with electronic ballast V, Hz for XFP0 Emergency Gear tray with electronic ballast 0-40V, Hz for XFP0EM Gear tray with electronic ballast V, Hz for XFP36 Gear tray with electronic ballast V, Hz for XFP40 Emergency Gear tray with electronic ballast 0-40V, Hz for XFP40EM Gear tray with electronic ballast V, Hz for XFP55 Gear tray with electronic ballast V, Hz for XFP65 Emergency Gear tray with electronic ballast 0-40V, Hz for XFP65EM Lampholder for T8 lamp Lampholder for PL lamp Battery pack for XFF EM Cover, gasket, screw, terminals, switch and interlock of jonction box Interlock Gasket Grease Kit M0 Exd Exe IIC Ex-td nickel plated cable gland for non armoured cable diameter 10,0-16,0mm, locknut, sealing gasket Kit M0 Ex-d IIC Ex-e II Ex-td double compression nickel plated cable gland for armoured cable diameter inner 6-1 outer 8,5-16, locknut, sealing gasket ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-140 UK 01/15 /3
Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22
Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance
More informationFloodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2
Features Wide or narrow beam Ex e integral junction box Flat or pole mounting Supplied with lamp installed Including accessories (cable gland & plug) Supplied with offshore grade paint Manufactured from
More informationLinear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components
More informationLinear fittings Fluorescent fitting EVN - Zones 2 & 22
Fluorescent fitting Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable
More informationLinear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More informationLinear fittings EVN Fluorescent fitting - zones 2 & 22
LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More informationLinear fittings EVNL LED fitting - zones 2, & 22
65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress
More informationLinear fittings EVTL Weatherproof LED fitting - Industrial applications
89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted
More informationLinear fittings EVTL Weatherproof LED fitting - Industrial applications
89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted
More informationLinear fittings EVT Weatherproof fluorescent fitting - Industrial applications
LIEAR FITTIGS - EVT FLUORESCET FITTIG - IDUSTRIAL APPLICATIOS 95 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationLinear fittings EVD Fluorescent fitting - zones 21 & 22
DTS LIER FITTIGS - EVD FLUORESET FITTIG - ZOES 21 & 22 83 EVD Fluorescent fitting - zones 21 & 22 Features Double central locking for ingress protection ll components mounted on hinged and removable gear
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationEXEL-L. Detail of the internal side. Transparent polycarbonate
EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin
More information110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W
/27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3
More informationLinear fittings EVT Weatherproof fluorescent fitting - Industrial applications
DTS LINER FITTINGS - EVT FLUORESENT FITTING - INDUSTRIL PPLITIONS 95 Features Double central locking for ingress protection ll components mounted on hinged and removable gear tray which gives easy access
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationEasy and safe installation
ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield
More informationFluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety
Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22
Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationLighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof
Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationFHL. Ex d. Body in aluminium
Ex d FHL Body in aluminium - Zones 1, 2, 21, 22 - Integrated electronic ballast - Power supply 24 V DC - Compact 24/36 W fluorescent tube - Degree of protection IP66 Guard in stainless steel Polycarbonate
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More informationIIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof
IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationEXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components
EXENC-L - Zone 2, Zone 21-22 - Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components Resin body reinforced polyester Fixing Brackets Transparent hood
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationWELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)
WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationEWE. Ex de. Cooling fins
EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationLighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22
FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationAVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips
AVN - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C Transparent polycarbonate diffuser Stainless steel clips Polyamide cable gland and plug
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationPROTECTA III. Construction Tough glass reinforced polyester body
PROTECTA III 20 Construction Tough glass reinforced polyester body Polycarbonate diffuser with high resistance to UV and stress cracking Robust hinges and multipoint compressive clamping of diffuser closure
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected
More informationATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen
Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,
More informationFL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22
Standard and Emergency Back-Up. Applications Light duty luminaire ideal for commercial and light industrial locations including hazardous areas designated as Zone 2 or 22 environments. Typical applications
More informationJ: Emergency lighting (optional) L: pole type X: ceiling type Mounting
Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone
More informationZone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108
Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating
More informationRLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22
Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018
More informationEWE. Cooling fins. Ex de
EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4
More informationL: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L
Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationPower (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13
Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationSheet Steel Emergency Light Fitting Series 6018
> For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS ellb 20... 1-5 W Metallic design for Zone 1 and 21 The ellb 20 explosion-protected ceiling light fitting with electronic ballast meet the requirements of ATEX-Directive
More informationTubular Light Fitting with LED Series 6036
> Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to high power LEDs used including driver
More informationEmergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
> As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00
More informationTUNNEL54. Safety and fire resistance VENTILATION LIGHTING
TUNNEL54 Safety and fire resistance VENTILATION LIGHTING 238 TUNNEL54 Safety and fire resistance VENTILATION TUNNEL54 fire resistant sockets for ventilators Page 240 LIGHTING TUNNEL54 junction boxes with
More informationZone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008
Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency
More informationLocal Control Station
Local Control Station As per table given below Ex'd', IIC, IP-66, FLP/WP Local Control Station and Switch MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFRS/104/I/IIC-IEC MFRS/104/IIC-IEC A B C D
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationEmergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
> For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can
More informationGRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators
Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2
More information7 Lighting Technology
7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting
More informationSheet-Steel Light Fittings Series 6014 / 6414
> As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive
More information7 Lighting Technology
7 Lighting Technology Sheet-Steel Emergency Light Fitting 09361E00 and 6418 (Zones 2, 21 and 22) emergency light fittings in sheet-steel can be used for safety illumination, especially in spraying and
More informationCEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1
CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de
More informationPY, SPY; FSQC, FP; EPC; AP
Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester
More informationFloodlight Series 6521/4
> The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight
More informationFlameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C
Enclosures Flameproof - Group IIB or IIB + 2 Carbon steel - DE8BC series The flameproof control cabinets DE8BC are designed for the control, automation, distribution boards, motor starters or any other
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationEJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...
EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES
Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationUSER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..
d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR LIGHT FITTING INX230LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk, tel: +48 58
More informationdefender-s NJZ-FEL-B Series Hazardous Locations&Explosive Atmospheres Zone1&2, Zone21&22 II 2G Ex d IIB T5 Gb II2D Ex tb IIIC 95 Max Db IP 66
defender-s NJZ-FEL-B Series Hazardous Locations&Explosive Atmospheres Zone1&2, Zone21&22 II 2G Ex d IIB T5 Gb II2D Ex tb IIIC 95 Max Db IP 66 features Defender-S explosion-proof light uses simple profile,
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR LIGHT FITTING INV360LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk, tel: +48 58
More information