PROTECTA III. Construction Tough glass reinforced polyester body
|
|
- Leslie Ford
- 6 years ago
- Views:
Transcription
1 PROTECTA III 20 Construction Tough glass reinforced polyester body Polycarbonate diffuser with high resistance to UV and stress cracking Robust hinges and multipoint compressive clamping of diffuser closure EPDM gasket with sealing lip Bolted through suspension points for great strength IP66/IP67 and deluge tested to DTS-01 Bolted through suspension points & fully compressed gasket Protecta with diffuser opened Easy access to lamps & control gear Quick release mains terminals to ballast & battery for ease of maintenance Reverse side of gear tray Reliability Robust electronics with End of Life (EOL) protection to IEC with EOL I and EOL II functionality Outstanding electrical immunity to mains disturbances including over-voltage, harmonics and spikes Vibration tested to DNV/Lloyds requirements Functional 9 minute self test every 13 days with full discharge and recharge self test every 3 months Comprehensive charge and discharge control management for maximum battery life Continuous monitoring of charge and function with fault indication and diagnosis Temperature resistant Ni-Cd battery technology
2 KEY FEATURES 21 Performance Automatic commissioning of emergency versions Regulated output, light is constant over full supply voltage range Very high electrical efficiency > 92% Excellent light output in emergency operation: 18W = 50% of one lamp, 36W = 45% of one lamp (/HEO option) Optional 3 hour emergency duration to EN Rapid recharge to 80% capacity Universal Remote Emergency Inhibition can be used with other pre-existing systems Relative light 120% 110% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Chalmit Ex e Protecta Chalmit Exe e Protecta vs Competitor Exe e Product Competitor Ex e Product Ambient (ºC) 20% greater light output at -20 C compared to other manufacturers Bi-colour LED indication Patented automatic lamp de-energisation on opening Quick release mains terminals Installation and Maintenance Standard fixing centres All parts mounted on gear tray, can be quickly removed leaving an Ex safe configuration Screwless mains terminals for rapid connection, no need for periodic checks Plug and socket battery connection for quick connection guaranteeing correct polarity Can be voltage tested with suitable current limited instruments Emergency lamp fault detection before the lamp becomes un-serviceable Self testing of battery capacity with low capacity LED indication Patented automatic lamp de-energisation on opening Common spare parts across Ex e fluorescent range (Protecta, Acclaim, Curie Elite) Screwed connection (optional)
3 PROTECTA III Ex e FLUORESCENT 22 The Protecta III is a proven and reliable T8 fluorescent luminaire. The Protecta s rugged, corrosion resistant construction (IP66/IP67) combined with an advanced high frequency ballast ensure minimum product maintenance is required. When access is required the Protecta III features an easy access clamp bar and automatic lamp de-energisation to allow quick and easy re-lamping. Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Reflector/Geartray Entry Termination Installation Control Gear Relamping Lampholder Burning Position Ingress Protection Electrical Supply Ex e mb q (Increased safety Encapsulation Powder filling) Group II Category 2 GD Zone 1 and 21 areas to EN and EN with installation to EN EC Type Examination Certificate Baseefa04ATEX0220 II 2 GD Ex e mb q IIC T4 Tamb 55 C GRP body with polycarbonate cover and brass suspension points White polyester painted zinc coated steel 4 x M20 cable entries, 2 at each end Quick release mains terminals - 3 core 4mm² max. conductor with looping and 16A rating through wiring. (6mm² terminations available - /SC option) Two M8 tapped brass inserts located on rear of body High Frequency Quick release diffuser clamp and hinged cover G13 (Bi-pin) Universal IP66/67 to EN V - 254V 50/60Hz, V dc Simple rugged construction Full length easy access diffuser clamp Advanced control gear gives 50/60Hz operation, high power correction factor and regulated lamp output that is 20% greater at -20 C than competitors Resistant to voltage fluctuations dc operation Automatic lamp de-energisation on opening Quick release mains terminals DTS-01 deluge tested Vibration tested to comply with Lloyds/DNV End of life (EOL) protection to IEC (with EOL I and EOL II functionality) International Approvals ATEX, GB (China), GOST, CSA and CEPEL IECEx Compliant
4 ATEX CATEGORY 2 ZONE 1 & 21 APPLICATIONS 23 Std. Cat No. Wattage Lamp TClass T C (Dust) Ambient C Weight PRGE/218/BI 2x18W T8 T to kg PRGE/236/BI 2x36W T8 T to kg PRGE/218/MO 2x18W T8 T to kg PRGE/236/MO 2x36W T8 T to kg MO - Mono-pin (Fa6 Cap) Lamps. Mono-pin Coding: Ex d e q. Options - Suffix to Catalogue No. /120 /M25 /SC /SB Specific voltage (110/130) M25 cable entries Screwed connection terminal block (up to 6mm² conductors) Stainless steel mounting bush /3P /LBE /EL /SE 3 phase termination facility (Not available if looping required) Looping both ends Extra live termination facility (to match emergency circuit) Spigot entry Accessories Should be ordered separately Pole mounting bracket assembly (38-42mm diameter poles) Pole mounting bracket assembly (48-52mm diameter poles) Pole mounting bracket assembly (58-62mm diameter poles) Hook type ceiling bracket assembly Ceiling mounting bracket assembly Eyebolt mounting assembly Flush mounting wall bracket assembly Looping kit (allows looping from both ends of luminaire) For details on outreach brackets see page 29. Catalogue Order Code SPOL SPOL SPOL SPRO SPRO SPRO SPRO SPROT-0021 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.
5 PROTECTA III E 24 Ex e EMERGENCY FLUORESCENT Utilising the same reliable design of the standard Protecta III, the emergency version also features intelligent battery and lamp management technology. The luminaire is capable of self commissioning and routine self-testing to ensure safe and dependable emergency operation. A high emergency output version is also available that increases the lumen output in emergency mode. Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Reflector/Geartray Entry Termination Installation Control Gear Relamping Lampholder Burning Position Ingress Protection Electrical Supply Battery Duration Emergency Output Ex e mb q (Increased safety Encapsulation Powder filling) Group II Category 2 GD Zone 1 and 21 areas to EN and EN with installation to EN EC Type Examination Certificate Baseefa04ATEX0220 II 2 GD Ex e mb q IIC T4 Tamb 55 C GRP body with polycarbonate cover and brass suspension points White polyester painted zinc coated steel 4 x M20 cable entries, 2 at each end Quick release mains terminals - 4 core 4mm² max. conductor with looping and 16A rating through wiring. (6mm² terminations available - /SC option) Two M8 tapped brass inserts located on rear of body High Frequency Quick release diffuser clamp and hinged cover G13 (Bi-pin) Universal IP66/67 to EN V - 254V 50/60Hz Internal Ni-Cd (6V) 90 minutes to EN % of one lamp (18W) 25% of one lamp (36W) Ability to detect and indicate impending end of emergency lamp life before actual failure Battery management, monitoring and automatic self test Emergency inhibition and mains power off re-start Automatic lamp de-energisation on opening DTS-01 deluge tested Vibration tested to comply with Lloyds/DNV End of life (EOL) protection to IEC (with EOL I and EOL II functionality) International Approvals ATEX, GB (China), GOST, CSA and CEPEL IECEx Compliant
6 ATEX CATEGORY 2 ZONE 1 & 21 APPLICATIONS 25 Std. Cat No. Wattage Lamp TClass T C (Dust) Ambient C Weight PRGE/218/BI/EM 2x18W T8 T to kg PRGE/236/BI/EM 2x36W T8 T to kg PRGE/218/MO/EM 2x18W T8 T to kg PRGE/236/MO/EM 2x36W T8 T to kg MO - Mono-pin (Fa6 Cap) Lamps. Mono-pin Coding: Ex d e mb q IIC. Options - Suffix to Catalogue No. /120 Specific voltage (110/130) /LBE Looping both ends /M25 M25 cable entries /HEO High emergency output - 45% (36W only) /SC /SB Screwed connection terminal block (up to 6mm² conductors) Stainless steel mounting bush /3H /RI 3 hour battery duration* Remote emergency inhibition facility (External switch ordered separately) /3P 3 phase termination facility (Not available if looping required) /SE Spigot entry * 18W = 30% of one lamp, 36W = 25% of one lamp Accessories Should be ordered separately Pole mounting bracket assembly (38-42mm diameter poles) Pole mounting bracket assembly (48-52mm diameter poles) Pole mounting bracket assembly (58-62mm diameter poles) Hook type ceiling bracket assembly Ceiling mounting bracket assembly Eyebolt mounting assembly Flush mounting wall bracket assembly Looping kit (allows looping from both ends of luminaire) Remote Ex switch for emergency inhibition (1 switch controls up to 10 luminaires) For details on outreach brackets see page 29. Catalogue Order Code SPOL SPOL SPOL SPRO SPRO SPRO SPRO SPROT-0021 SPROT-0033 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.
7 PROTECTA III S/S STAINLESS STEEL 26 Ex e FLUORESCENT The Protecta III is also available in a stainless steel body version. This incorporates the same design and monitoring features found in the GRP body Protecta. The increased durability of its stainless steel construction makes this luminaire ideal for applications where there is a high risk of mechanical damage or exposure to chemical agents. Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Reflector/Geartray Entry Termination Installation Lampholder Control Gear Relamping Burning Position Ingress Protection Electrical Supply Battery Duration Emergency Output Ex e mb q (Increased safety Encapsulation Powder filling) Group II Category 2 GD Zone 1 and Zone 21 areas to EN and EN with installation to EN EC Type Examination Certificate Baseefa04ATEX0220 II 2 GD Ex e mb q IIC T4 Tamb 55 C (45 C for emergency version) Marine grade 316S31 stainless steel body with polycarbonate cover White polyester painted zinc coated steel 4 x M20 cable entries, 2 at each end Quick release mains terminals - 3 core 4mm² max. conductor with looping and through wiring facility. 4 core 4mm² connectors on emergency). (6mm² terminations available - /SC option) Two M8 tapped stainless steel inserts located on rear of body G13 (Bi-pin) High Frequency Quick release diffuser clamps and hinged cover Universal IP66 to EN V - 254V 50/60Hz 220V - 300V dc (non-emergency only) Internal Ni-Cd (6V) 90 minutes to EN % of one lamp (18W) 25% of one lamp (36W) 316 Stainless steel body and clamp bar Advanced control gear gives 50/60Hz operation, high power correction factor and regulated lamp output that is 20% greater at -20 C Automatic lamp de-energisation on opening Resistance to voltage fluctuations Battery management, monitoring and automatic self test dc operation (non-emergency only) Ability to detect and indicate impending end of emergency lamp life before actual failure End of life (EOL) protection to IEC (with EOL I and EOL II functionality) International Approvals ATEX, GB (China), GOST, CSA and CEPEL IECEx Compliant
8 ATEX CATEGORY 2 ZONE 1 & 21 APPLICATIONS 27 Std. Cat No. Wattage Lamp TClass T C (Dust) Ambient C Weight PRSE/218/BI 2x18W T8 T to kg PRSE/236/BI 2x36W T8 T to kg PRSE/218/BI/EM 2x18W T8 T to kg PRSE/236/BI/EM 2x36W T8 T to kg PRSE/218/MO 2x18W T8 T to kg PRSE/236/MO 2x36W T8 T to kg PRSE/218/MO/EM 2x18W T8 T to kg PRSE/236/MO/EM 2x36W T8 T to kg MO - Mono-pin (Fa6 Cap) Lamps. Mono-pin Coding: Ex d e q. Mono-pin emergency coding: Ex d e mb q IIC. Options - Suffix to Catalogue No. /120 /M25 /SC /3P Specific voltage (110/130V) M25 cable entries Screwed connection terminal block (up to 6mm² conductors) 3 phase termination facility (Not available if looping required) /LBE /EL /HEO /3H Looping both ends Extra live termination facility (compatible with 4 core switched emergency circuits) High emergency output - 45% (36W only) 3 hour battery duration* * 18W = 30% of one lamp, 36W = 25% of one lamp Accessories Should be ordered separately Pole mounting bracket assembly (38-42mm diameter poles) Pole mounting bracket assembly (48-52mm diameter poles) Pole mounting bracket assembly (58-62mm diameter poles) Hook type ceiling bracket assembly Ceiling mounting bracket assembly Eyebolt mounting assembly Flush mounting wall bracket assembly Looping kit (allows looping from both ends of luminaire) Remote Ex switch for emergency inhibition (1 switch controls up to 10 luminaires) For details on outreach brackets see page 29. Catalogue Order Code SPOL SPOL SPOL SPRO SPRO SPRO SPRO SPROT-0021 SPROT-0033 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.
9 PROTECTA III 28 Pole Mounting Bracket Assembly Cat No. SPOL /100002/ Pole mounting bracket to suit pole diameter (38-42mm) SPOL (48-52mm) SPOL (58-62mm) SPOL Hook Type Ceiling Bracket Assembly Cat No. SPRO Ceiling Mounting Bracket Assembly Cat No. SPRO Eyelet Mounting Assembly Cat No. SPRO5-0005
10 MOUNTING OPTIONS 29 Flush Mounting Wall Bracket Assembly Cat No. SPRO Note: All brackets are made from 316 Stainless Steel Wall Mounting Outreach Bracket Cat No. NPRO4-0007/0008/0012 Pole length A for use with the following: 1. 18W and 36W spigot entry body, size A = 250mm Cat No. NPRO W body c/w pole clamps (SPOL ), size A = 650mm Cat No. NPRO W body c/w pole clamps, (SPOL ) size A = 1100mm Cat No. NPRO Pole clamps for items 2 & 3 must be ordered separately, see SPOL W Spigot Entry Cat No. PRGE/218/BI/SE 36W Spigot Entry Cat No. PRGE/236/BI/SE
11 PROTECTA n 68 NORMAL and EMERGENCY LIGHTING Ex n FLUORESCENT The Protecta n utilises the proven strength and integrity as the Protecta III but is certified for use in Zone 2, Zone 21 and Zone 22 hazardous areas. The luminaire is recommended for use in areas where high levels of ingress protection is required Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Reflector Entry Termination Installation Control Gear Relamping Burning Position Ingress Protection Electrical Supply Battery Duration Emergency Output Ex na (Non-sparking) Group II Category 3 GD Zone 2 and Zone 22 areas to EN and EN with installation to EN Type Examination Certificate Baseefa08ATEX0227 IEC Certificate IECExBAS II 3 GD Ex na Refer to table for T rating and Ambient GRP body with polycarbonate cover and brass suspension points White polyester painted zinc coated steel 4 x M20 cable entries, 2 at each end 3 core 4mm² max. conductor with looping and through wiring 16A rating. 4 core 4mm² connectors on emergency). (6mm² terminations available - /SC option) Two M8 tapped brass inserts located on rear of body. High Frequency electronic ballast Emergency - electronic/inverter Quick release diffuser clamp and hinged cover Universal IP66/67 to EN V 50/60Hz Ni-Cd 6V (Emergency version only) 3 hours (Emergency version only) 18W 32% of one lamp 36W 14% of one lamp Easy access to suspended control gear tray High frequency control gear gives 50/60Hz operation, high power factor correction and regulation of lamp output dc operation (non-emergency only) Vibration tested to comply with Lloyds/ DNV DTS-01 deluge tested End of life (EOL) protection to IEC (with EOL I and EOL II functionality) Suitable for Zone 21 (Dust) areas Type Examination Certificate Baseefa08ATEX0228 Coding II 2D Ex td A21 T85 C International Approvals ATEX IECEx Compliant
12 ATEX CATEGORY 3 ZONE 2, 21 & 22 APPLICATIONS 69 Std. Cat No. Wattage TClass(Gas) T C (Dust) Ambient C Weight PR2N/218/BI 2x18W T to kg PR2N/136/BI 1x36W T to kg PR2N/236/BI 2x36W T to kg PR2N/218/BI/EM 2x18W T to kg PR2N/136/BI/EM 1x36W T to kg PR2N/236/BI/EM 2x36W T to kg Options - Suffix to Catalogue No. /120 Specific voltage (110V-130V) /3P Three phase termination /SC /M25 Screwed connection terminal block (up to 6mm² conductors) M25 cable entries /MF /IS /SE Mains fuse Isolation switch Spigot entry Accessories Should be ordered separately Pole mounting bracket assembly (38-42mm diameter poles) Pole mounting bracket assembly (48-52mm diameter poles) Pole mounting bracket assembly (58-62mm diameter poles) Hook type ceiling bracket assembly Ceiling bracket assembly Flush mounting wall bracket assembly Eyebolt mounting assembly Looping Kit (allows looping from both ends of luminaire) 18W wall mounting outreach bracket (use with SPOL ) Catalogue Order Code SPOL SPOL SPOL SPRO SPRO SPRO SPRO SPROT-0021 NPRO W wall mounting outreach bracket (use with SPOL ) Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications. NPRO4-0012
13 PROTECTA 96 SURFACE MOUNTED FLUORESCENT The Protecta is a proven and reliable T8 fluorescent luminaire. The Protecta s rugged, corrosion resistant construction (IP66/IP67) combined with an advanced high frequency ballast ensure minimum product maintenance is required. When access is required the Protecta Industrial features an easy access clamp bar and automatic lamp de-energisation to allow quick and easy re-lamping. Standard Specification Features Ingress Protection Enclosure Entries Termination Reflector/Gear-tray Mounting Control Gear Relamping IP66/67 to EN60529 GRP body with clear polycarbonate diffuser and brass suspension points 4 x M20 cable entries (2 each end) Quick release mains terminals - 3 core 4mm² max. conductor with looping and 16A rating through wiring. (6mm² terminations available - /SC option) White polyester painted zinc coated steel Two M8 brass inserts on rear of body High frequency electronic control gear Via quick-release diffuser clamp and hinged diffuser Simple rugged construction Full length easy access diffuser clamp Hinged cover Standard fixing centres When fitted high frequency control gear gives 50/60Hz operation, high power factor correction and regulation of lamp output Quick release mains terminals DTS-01 deluge tested Vibration tested to comply with Lloyds/DNV A copper and iron version is also available. To order substitute /HF with /ES and specify the voltage Electrical Supply V 50/60Hz
14 INDUSTRIAL and MARINE APPLICATIONS 97 Std. Cat No. Wattage Lamp TClass Lampholder Weight PRGI/118/BI/HF 1x18W Fluorescent T8 G13 6kg PRGI/218/BI/HF 2x18W Fluorescent T8 G13 6.1kg PRGI/136/BI/HF 1x36W Fluorescent T8 G13 9.6kg PRGI/236/BI/HF 2x36W Fluorescent T8 G13 9.8kg Options - Suffix to Catalogue No. /--- Specific voltage - Copper/iron ballasts: 120, 220, 230, 254V /3P 3 phase termination facility (not available if looping is required) /ES Electronic start (copper/iron ballast only) /M25 M25 cable entry /60 /EL 60Hz supply (copper/iron ballasts only) Extra live termination (compatible with 4 core switched emergency models) /SC /SB Screwed connection terminal block (up to 6mm² conductors) Stainless steel mounting bush /MF Mains fuse /SE Spigot entry Accessories Should be ordered separately Pole mounting bracket assembly (38-42mm diameter poles) Pole mounting bracket assembly (48-52mm diameter poles) Pole mounting bracket assembly (58-62mm diameter poles) Hook type ceiling bracket assembly Ceiling bracket assembly Flush mounting wall bracket assembly Eyebolt mounting assembly Looping Kit (allows looping from both ends of luminaire) 18W wall mounting outreach bracket (use with SPOL ) Catalogue Order Code SPOL SPOL SPOL SPRO SPRO SPRO SPRO SPROT-0021 NPRO W wall mounting outreach bracket (use with SPOL ) Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications. NPRO4-0012
15 PROTECTA E 98 EMERGENCY FLUORESCENT The Protecta Industrial has the same rugged and proven design as the Ex Protecta. This includes high ingress protection with DTS-01 deluge compliance and vibration resistance in accordance with Lloyds/DNV standards. The Emergency version also features an internal battery to allow operation in the event of mains power failure. Standard Specification Features Ingress Protection Enclosure Entries Termination Reflector/Gear-tray Mounting Control Gear Relamping IP66/67 to EN60529 GRP body with clear polycarbonate diffuser and brass suspension points 4 x M20 cable entries (2 each end) Quick release mains terminals - 3 core 4mm² max. conductor with looping and 16A rating through wiring. (6mm² terminations available - /SC option) White polyester painted zinc coated steel Two M8 brass inserts on rear of body High frequency ballast & invertor c/w battery pack Via quick-release diffuser clamp and hinged diffuser Simple rugged construction Full length easy access diffuser clamp Standard fixing centres High frequency control gear gives 50/60Hz operation, high power factor correction and regulation of lamp output Quick release mains terminals DTS-01 deluge tested Vibration tested to comply with Lloyds/DNV Optional battery monitoring and self-testing control gear Electrical Supply V 50/60Hz Battery Ni-Cd (6V) Duration 3 Hours to EN Emergency Output 32% of one lamp (18W) 14% of one lamp (36W)
16 INDUSTRIAL and MARINE APPLICATIONS 99 Std. Cat No. Wattage Lamp TClass Lampholder Weight PRGI/118/BI/EM 1x18W Fluorescent T8 G13 8.1kg PRGI/218/BI/EM 2x18W Fluorescent T8 G13 8.3kg PRGI/136/BI/EM 1x36W Fluorescent T8 G kg PRGI/236/BI/EM 2x36W Fluorescent T8 G kg Options - Suffix to Catalogue No. /120 /NM /MF /3P V Non-maintained (single lamp models only) Mains fuse 3 phase termination facility (not available if through wiring is required) /SC /SB /LBE /BMT Screwed connection terminal block (up to 6mm² conductors) Stainless steel mounting bush Looping both ends Battery monitoring and self-test /M25 M25 cable entry /SE Spigot entry Accessories Should be ordered separately Pole mounting bracket assembly (38-42mm diameter poles) Pole mounting bracket assembly (48-52mm diameter poles) Pole mounting bracket assembly (58-62mm diameter poles) Hook type ceiling bracket assembly Ceiling bracket assembly Flush mounting wall bracket assembly Eyebolt mounting assembly Looping Kit (allows looping from both ends of luminaire) 18W wall mounting outreach bracket (use with SPOL ) Catalogue Order Code SPOL SPOL SPOL SPRO SPRO SPRO SPRO SPROT-0021 NPRO W wall mounting outreach bracket (use with SPOL ) Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications. NPRO4-0012
17 PROTECTA S/S 100 STAINLESS STEEL FLUORESCENT The Protecta is also available in a stainless steel body version. This incorporates the same design and monitoring features found in the GRP body Protecta. The increased durability of its stainless steel construction makes this luminaire ideal for applications where there is a high risk of mechanical damage or exposure to chemical agents. Standard Specification Features Ingress Protection Enclosure Entries Termination Installation Reflector/Gear-tray Control Gear Relamping Electrical Supply IP66/67 to EN60529 Marine grade 316S31 stainless steel body with clear polycarbonate diffuser 4 x M20 cable entries (2 each end) Quick release mains terminals - 3 core 4mm² max. conductor with looping and 16A rating through wiring. (6mm² terminations available - /SC option) Two M8 tapped stainless steel inserts located on rear of body White polyester painted zinc coated steel High frequency electronic control gear Via quick-release diffuser clamp and hinged diffuser V 50/60Hz Emergency version 220/254V 50/60Hz Simple rugged construction Hinged cover with easily removeable cover clamps Standard fixing centres High frequency control gear gives 50/60Hz operation, high power factor correction and regulation of lamp output Quick release mains terminals Resistance to voltage fluctuations Optional battery monitoring and self-testing control gear A non-emergency copper and iron version is also available. To order substitute /HF with /ES and specify the voltage Battery Ni-Cd (6V) Duration 3 Hours Emergency Output 32% of one lamp (18W) 14% of one lamp (36W)
18 INDUSTRIAL and MARINE APPLICATIONS 101 Std. Cat No. Wattage Lamp TClass Lampholder Weight PRSI/118/BI/HF 1x18W Fluorescent T8 G13 5.9kg PRSI/218/BI/HF 2x18W Fluorescent T8 G13 6.2kg PRSI/136/BI/HF 1x36W Fluorescent T8 G13 9.6kg PRSI/236/BI/HF 2x36W Fluorescent T8 G kg PRSI/118/BI/EM 1x18W Fluorescent T8 G13 8.7kg PRSI/218/BI/EM 2x18W Fluorescent T8 G13 9.0kg PRSI/136/BI/EM 1x36W Fluorescent T8 G kg PRSI/236/BI/EM 2x36W Fluorescent T8 G kg Options - Suffix to Catalogue No. /120 /ES /--- /60 /EL V High frequency ballast (for /EM Emergency models only) Electronic start (copper/iron ballast only) Specific voltage (120*, 220, 230 & 254V only available copper/iron gear) 60Hz supply (copper/iron ballasts only) Extra live termination (Compatible with four core switched emergency models) * 120V copper/iron gear - non emergency only /M25 /SC /MF /3P /LBE /BMT M25 cable entries Screwed connection terminal block (up to 6mm² conductors) Mains fuse 3 phase termination facility Looping both ends Battery monitoring and self-test Accessories Should be ordered separately Catalogue Order Code Pole mounting bracket assembly (38-42mm diameter poles) SPOL Pole mounting bracket assembly (48-52mm diameter poles) SPOL Pole mounting bracket assembly (58-62mm diameter poles) SPOL Hook type ceiling bracket assembly SPRO Ceiling bracket assembly SPRO Flush mounting wall bracket assembly SPRO Eyebolt mounting assembly SPRO Looping Kit (allows looping from both ends of luminaire) SPROT W wall mounting outreach bracket (use with SPOL ) NPRO W wall mounting outreach bracket (use with SPOL ) NPRO Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.
Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationMaking Hazardous Environments Work
Making Hazardous Environments Work Our Vision We aim to be the first choice supplier of lighting equipment to hazardous and industrial markets worldwide. 1 CONTENTS PAGE 1 VICTOR RANGE 2-3 INTRODUCTION
More informationProtecta III GRP ATEX
EOL Protecta III GRP ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read the following instructions carefully prior to installation or maintenance of this equipment. Types
More informationLinear fittings EVN Fluorescent fitting - zones 2 & 22
LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray
More informationLinear fittings EVNL LED fitting - zones 2, & 22
65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress
More informationProtecta Ex na Fluorescent Luminaire
Issue 00 Protecta Ex na Fluorescent Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important : Please read these instructions carefully before installing or maintaining this equipment.
More informationFluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety
Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous
More informationOur Vision. We aim to be the first choice supplier of lighting equipment to hazardous and industrial markets worldwide.
Our Vision We aim to be the first choice supplier of lighting equipment to hazardous and industrial markets worldwide. 1 CONTENTS PAGE 1 VICTOR RANGE 2-3 INTRODUCTION LITEGUIDE LIGHTING DESIGN SOFTWARE
More information1000W and 2000W versions
503 FLOODLIGHT 126 600W HPS 1000W and 2000W versions The 503 is a high powered floodlight with a wide ambient temperature range. The high upper ambient and corrosion resistant aluminium constriction, make
More informationLinear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More informationLinear fittings Fluorescent fitting EVN - Zones 2 & 22
Fluorescent fitting Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable
More informationTubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22
Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation
More informationEmergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
> As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00
More informationATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22
Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against
More informationEasy and safe installation
ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield
More informationTubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22
Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More information110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W
/27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3
More informationLinear fittings EVT Weatherproof fluorescent fitting - Industrial applications
LIEAR FITTIGS - EVT FLUORESCET FITTIG - IDUSTRIAL APPLICATIOS 95 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationLinear fittings EVTL Weatherproof LED fitting - Industrial applications
89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted
More informationEXEL-L. Detail of the internal side. Transparent polycarbonate
EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin
More informationPower (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13
Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.
More informationLighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22
FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full
More informationLinear fittings EVTL Weatherproof LED fitting - Industrial applications
89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationLinear fittings EVD Fluorescent fitting - zones 21 & 22
DTS LIER FITTIGS - EVD FLUORESET FITTIG - ZOES 21 & 22 83 EVD Fluorescent fitting - zones 21 & 22 Features Double central locking for ingress protection ll components mounted on hinged and removable gear
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationFL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22
Standard and Emergency Back-Up. Applications Light duty luminaire ideal for commercial and light industrial locations including hazardous areas designated as Zone 2 or 22 environments. Typical applications
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationSheet-Steel Light Fittings Series 6014 / 6414
> As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationZone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108
Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationEVZ Series (Small body) Explosion protected luminaire Operating Instructions
EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East
More informationLinear fittings EVT Weatherproof fluorescent fitting - Industrial applications
DTS LINER FITTINGS - EVT FLUORESENT FITTING - INDUSTRIL PPLITIONS 95 Features Double central locking for ingress protection ll components mounted on hinged and removable gear tray which gives easy access
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationSheet Steel Emergency Light Fitting Series 6018
> For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and
More informationHAZ AREA LIGHTING. Product Brochure. Design to Manufacture FOR HAZARDOUS AREAS. Engineering Solutions. An A-Belco Group Company
HAZ AREA LIGHTING FOR HAZARDOUS AREAS Product Brochure Engineering Solutions Design to Manufacture An A-Belco Group Company The Hadar Lighting Range Designed and manufactured in the UK by A-Belco Hazardous
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationCompact Sheet-Steel Light Fittings Series 6114
> As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationGlass Reinforced Polyester Enclosures
42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,
More informationIIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof
IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire
More informationexplosive environments Lighting
explosive environments Lighting CLASSIFICATION OF THE ZONES GAS AND VAPOURS DUST PRESENCE OF EXPLOSIVE ATMOSPHERE ZONE 0 ZONE 20 Category 1G Category 1D Permanent ZONE 1 ZONE 21 Category 2G Category 2D
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationEmergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
> For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More information7 Lighting Technology
7 Lighting Technology Sheet-Steel Emergency Light Fitting 09361E00 and 6418 (Zones 2, 21 and 22) emergency light fittings in sheet-steel can be used for safety illumination, especially in spraying and
More informationFV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations
Applications For use in hazardous locations defined by the NEC and CEC as Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Marine Outdoor Salt Water; UL1598A and. As well
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationOperating Instructions
Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationZone 1 Linear Range - Installation Guide
Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text
More informationLighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof
Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationLOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES
L KILLARK TI IGH NG HA Z LO C LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES High temperature rated silicone gasketing provides Type 4X & IP66 sealing. Diffused Clear 2 Lens Choices: Clear for
More informationL: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L
Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:
More information7 Lighting Technology
7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources
More informationAVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips
AVN - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C Transparent polycarbonate diffuser Stainless steel clips Polyamide cable gland and plug
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationLOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES
KILLARK Z A H LO C LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES High temperature rated silicone gasketing provides NEMA 4X & IP66 sealing. Diffused 2 Lens Choices: Clear for maximum lumens
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected
More informationJ: Emergency lighting (optional) L: pole type X: ceiling type Mounting
Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationThe ultimate low voltage temporary LED lighting solution
LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkExTM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts
More informationSPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz
ORION ROAD LANTERN Arc shape cooling guide design, resulting in effective heat dissipation and dust removal ability Combined optical lens, ideal for road lighting requirements Power-off protection socket,
More informationThe ultimate low voltage temporary LED lighting solution
LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkEx TM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts
More informationEXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components
EXENC-L - Zone 2, Zone 21-22 - Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components Resin body reinforced polyester Fixing Brackets Transparent hood
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationPauluhn ZPL explosionproof LED luminaires For drilling and marine applications
Pauluhn ZPL explosionproof linear LEDs are designed to replace fluorescent T12, T8 and T5HO lighting on marine vessels and land-based and offshore drilling platforms. The rugged and durable design features
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationRLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22
Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018
More informationZone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008
Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected
More informationControl Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations
Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC
More information7 Lighting Technology
7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting
More informationAreamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent
Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1, Groups E, F, G Class II Division 2, Groups F, G Class III Simultaneous Exposure Type 3R, 4, 4X IP66/67 Applications
More informationATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen
Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationAPPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.
Haz HazMax Pinnacle/al APPLICATIONS Hazardous locations Watertight requirements Dusttight requirements Oil and gas exploration and production Waste water treatment plants Pipeline compressor / pumping
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More information