Material Description Quantity UOM
|
|
- Darcy Clarke
- 5 years ago
- Views:
Transcription
1 Page : 1 / 4 OIL INDIA LIMITED (A Govt. of India Enterprise) P.O. Duliajan , Assam. Fax No , material@oilindia.in Bid Security Amount : INR 0.00 OR USD 0.00 (or equivalent Amount in any currency) Bidding Type : Single Bid (Composite Bid) Bid Closing On Bid Opening On : at 13:00 hrs. (IST) : at 13:00 hrs. (IST) Performance Guarantee : Not Applicable OIL INDIA LIMITED have issued Limited tenders to following parties for items detailed below. For General Terms & Conditions, please refer to Document No. MM/GLOBAL/01/2005 available in OIL's web site: 10 SPARES FOR REMOTE IGNITION AND PILOT FLAME FAILURE SHUTDOWN SYSTEM 2 NO 20 0C PORTABLE IGNITER Make and Part No. : INVALCO; or equivalent Function : To ignite the pilot flame in Natural gas fired Burners Features : Portable, Flameproof and battery operated Battery : 12V, rechargeable type. HIGH VOLTAGE IGNITION WIRE Make; Model No.; Part No. : INVALCO; BELDEN ; or Properties : High voltage handling and Heat resistant Function : Connects between Portable Ignitor and Electrode to facilitate ignition for pilot flame. IGNITER ROD ASSEMBLY Make and Part No. : INVALCO; or Function : To provide ignition for pilot flame in conjunction with Portable Ignitor. 40 M 40 HIGH VOLTAGE CONNECTOR Make and Brand name : INVALCO; Rajah Ferrule SSN Part No : or Connector Ignitor clip size : 1/4 inch ID Function : To provide connection between the and the Electrode. High voltage cable 8 NO 50 INSULATOR Make and Part No. : INVALCO; or Function : To provide isolation between the high voltage connector and the body of the burner. 60 INSULATOR HOLDER
2 Page : 2 / 4 Make and Part No. : INVALCO; or Function : To hold the Insulator with pilot line. 70 HOLDING STRAP Make and Part No. : INVALCO; or Function : To hold the Ignitor Rod assembly with the Pilot line. 80 HIGH VOLTAGE CONNECTOR ASSEMBLY AND FEED THROUGH Make and Part No. : INVALCO; or Function : To provide connection between Portable Igniter and electrode (through high voltage cable and connectors). 90 MIXER Make; Model No. and Part No. : INVALCO; Model 100 Mixer; or Connection : 1/2" inch Female connector Function : To maintain air-fuel ratio to the pilot burner. 100 ORIFICE Make; Model No. and Part No. : INVALCO; Orifice#72; or Suitable for Model 100 Gas Mixer Function : To maintain air-fuel ratio for the pilot burner. 110 PILOT BURNER Make; Model No. and Part No. : INVALCO; RHSB Pilot Burner; or Connection : 1/2" inch NPT Function : To provide pilot flame in the Natural gas fired Heater vessel. 120 PILOT GUARD ASSEMBLY Make; Model No. and Part No. : INVALCO; CM-7; P or Function : To provide positive shut-off of the gas supply to both the pilot and main burner in the event of pilot flame out in gas fired Heater vessels Features : No external power source for operation, Ensures that burner port is closed during pilot ignition, Latchable reset for pilot ignition. Pilot flame Sensing : Thermocouple Length of thermocouple element : 15 feet Temperature limit of the sensing element : 815 Degree C (1500 Degree F) Supply pressure : 15 to 50 PSIG (Operation should not be effected by pressure variation within these limits) Reaction time for Ignition to latch-in : 90 seconds maximum Reaction time for Flame-out to Shut-off : 45 seconds maximum Materials : Body material : Anodized Aluminium Internal parts : 303 Stainless Steel Spring material : 302 Stainless Steel Elastomer seals : Viton Failure Mode : Unit will fail in the closed position.
3 Page : 3 / PILOT GAS REGULATOR Make; Model No. and Part No. : INVALCO; Y ; or equivalent Function : To provide regulated gas supply to the Pilot Burner Process connection : 6mm (1/4 inch) Maximum Inlet Pressure : 100 psi Outlet Pressure : Adjustable full range. FUEL SHUT-OFF VALVE Make; Model No. and Part No. : INVALCO; DSG-7501B-468; or Function : Fuel shut-off in case of pilot flame failure in Natural gas fired Heater vessels Body material : Ductile Iron A-395 Body cover/lower diaphragm case : Ductile Iron A-395 End connections : 1" NPT(F) Diaphargm actuator Case material : Cast Aluminium Diaphragm material : Nylon reinforced Buna-N diaphragm Maximum working Pressure of Actuator : 70 PSI Maximum containment Pressure of Actuator : 100 PSI Packing : Standard O-Ring, Buna-N Maximum working Pressure of vlave : 150 PSI Stem material of the valve : 303 Stainless Steel Plug type : Soft plug for tight shut-off Spring type : Adjustable spring. Special Notes : 1. The items shall be brand new, unused & of prime quality. Bidders shall warrant (in the event of an order) that the product supplied will be free from all defects & fault in material, workmanship & manufacture and shall be in full conformity with ordered specifications. This clause shall be valid for 18 months from date of shipment/dispatch or 12 months from date of receipt of the items. Bidders must confirm the same while quoting. 2. The minimum FOB/FCA charges in case of partial order for reduced quantity/items shall have to be indicated by the bidder. In case this is not indicated specifically, the charges quoted would be prorata calculated and the same will be binding on the bidder. 3. Bidder shall provide proper documentation of all sub units and the system as a whole, along with the offer. 3. In the event of an order, bidder shall provide one set of operation and maintenance manual along with each equipment. 4. All the items shall be procured from same source for the reason of compatibility. 5. Bidders other than OEM (Original Equipment Manufacturer) must submit proper valid authorisation certificate alongwith the warranty back-up from OEM failing which offer shall be liable for rejection.
4 Page : 4 / 4 6. Validity of the offers should be 120 days. (Please refer clause 1.2 of Section 'D' of MM/GLOBAL/01/2005). Bids with lesser validity shall be rejected. 7. Quotation must be submitted in triplicate. 8. The items covered by this tender shall be used by Oil India Limited in the PEL/ML areas which are issued/renewed after 01/04/99 and hence Nil Customs Duty during import will be applicable. Indigenous bidder shall be eligible for Deemed Export Benefit against this purchase. Details of Deemed Export are furnished vide Addendum to MM/GLOBAL/01/2005 enclosed.
5 Tender No. Tender Date Bid Closing On Bid Opening On : DFD4428L10/06 : : at 13:00 hrs.(ist) : at 13:00 hrs.(ist) Tender issued to following parties only: Slno V_Code Vendor Name City/Country SONAL ENTERPRISES NEW YORK AKV ENTERPRISES(CANADA) PETRO MECH COMPANY INC KATY ZICOM EQUIPMENT PTE LTD SINGAPORE FMC TECHNOLOGIES INC. TEXAS
ELECTRIC MOTOR DRIVEN, SKID MOUNTED CHEMICAL DOZING PUMP. The motor shall be 3 phase, squirrel cage, AC Induction motor.
Page:1/5 OIL INDIA LIMITED (A Govt. of India Enterprise) P.O. Duliajan-786602, Assam. Fax No. 91-374-2800533, E-mail:material@oilindia.in Tender No. & Date : DFD0792L09/08 21.10.2008 Bid Security Amount
More informationTechnical Specification for Electric Motor Driven, Skid Mounted Chemical Dosing Pump:
Page:1/5 OIL INDIA LIMITED (A Govt. of India Enterprise) P.O. Duliajan-786602, Assam. Fax No. 91-374-2800533, E-mail:material@oilindia.in Tender No. & Date : DFD1892L09/08 23.01.2009 Bid Security Amount
More informationMaterial Description Quantity UOM. 50 mm (2 Inch) NB, ANSI 1500 CLASS Control Valves for Oil Field (Sweet) Natural Gas Services:
Page : 1 / 5 OIL INDIA LIMITED (A Govt. of India Enterprise) P.O. Duliajan-786602, Assam. Fax No. 91-374-2800533, E-mail:material@oilindia.in Tender No. & Date : DFD4576L15/07 12.08.2014 Bid Security Amount
More informationMaterial Description Quantity UOM ELECTRIC MOTOR DRIVEN, SKID MOUNTED, RECIPROCATING PLUNGER TYPE CHEMICAL DOSING PUMP.
Page : 1 / 6 OIL INDIA LIMITED (A Govt. of India Enterprise) P.O. Duliajan-786602, Assam. Fax No. 91-374-2800533, E-mail:material@oilindia.in Tender No. & Date : DFD1192L17/06 20.05.2016 Bid Security Amount
More informationIMPORTANT NOTE (C) SENIOR ADVISER(CONTRACT & PURCHASE), OIL INDIA LIMITED, PLOT NO. 19 SECTOR 16A NOIDA
IMPORTANT NOTE BID DOCUMENT HAS BEEN DISPLAYED TO UNDERSTAND THE REQUIREMENT ONLY. PARTIES INTERESTED TO PARTICIPATE AGAINST THIS TENDER SHALL HAVE TO PURCHASE THE TENDER DOCUMENTS FROM ANY OF OIL S DESIGNATED
More informationIMPORTANT NOTE (C) SENIOR ADVISER (CONTRACT & PURCHASE), OIL INDIA LIMITED PLOT NO.19, SECTOR - 16A NOIDA
IMPORTANT NOTE BID DOCUMENT HAS BEEN DISPLAYED TO UNDERSTAND THE REQUIREMENT ONLY. PARTIES INTERESTED TO PARTICIPATE AGAINST THIS TENDER SHALL HAVE TO PURCHASE THE TENDER DOCUMENTS FROM ANY OF OIL S DESIGNATED
More informationOil India Limited (A Govt. of India Enterprise) P.O. Duliajan , Assam
Oil India Limited (A Govt. of India Enterprise) P.O. Duliajan 786602, Assam Tender No. & Date: SDG 1468P17/07 dated: 14.06.2016 Tender Fee : INR 6,000.00 OR USD 100.00 Bid Security Amount : INR 105,340.00
More informationOIL INDIA LIMITED Fax (A Govt. of India Enterprise) Udyan Vihar, Narengi, Guwahati, Assam
OIL INDIA LIMITED Fax-91 0361 2643686 (A Govt. of India Enterprise) Email-oilmatpl@oilindia.in Udyan Vihar, Narengi, Guwahati, Assam OIL INDIA LIMITED invites sealed tenders for the following: Tender No.
More informationThe Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor
OPERATIONS MANUAL The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor Safe, reliable ignition and flame failure protection combined with a proven, completely self-powered
More informationPRESSURE REDUCING CONTROL VALVES
PROJECT NAME LOCATION PRESSURE REDUCING CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 1 in. (25 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL
More informationIgniter, BMS & Valve Parts Directory Contact Us Toll Free:
Igniter, BMS & Valve Parts Directory Phone: (03) 32-9 Email: sales@combustex.com Web: www.combustex.com Combustex is ready to provide you with the spare parts you need to keep your Pilot Pro Igniters,
More informationPRESSURE RELIEF / SUSTAINING CONTROL VALVES
PROJECT NAME LOCATION PRESSURE RELIEF / SUSTAINING CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 1 in. (25 mm) through 36 in. (900 mm) Control Valves PART
More informationMark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation
Mark 6127 Series Pressure Reducing Valves The primary function of the Mark 6127 is to reduce a greater upstream pressure to a lesser, more manageable downstream pressure, operating without regard to either
More informationTender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02
Tender No:- MTL/PUR/213/Elect/2015-16 (K)/9 Date:-26/10/2016 Type Of Bid Bidding type Bid closing On Bid Opening On EMD : LIMITED TENDER : Single Bid : 18/11/2016 at 14.00 hrs.(ist) : : As per Annexure
More informationCOMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE
PROJECT NAME LOCATION COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 1 in. (25 mm) through 36 in. (900
More informationSOLENOID CONTROL VALVE
PROJECT NAME LOCATION SOLENOID CONTROL VALVE INTRODUCTION This specification covers the design, manufacture, and testing of 4 in. (100 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL 1. Standard
More informationIMPORTANT NOTE (C) SENIOR ADVISER (CONTRACT & PURCHASE), OIL INDIA LIMITED PLOT NO.19, SECTOR - 16A NOIDA
IMPORTANT NOTE BID DOCUMENT HAS BEEN DISPLAYED TO UNDERSTAND THE REQUIREMENT ONLY. PARTIES INTERESTED TO PARTICIPATE AGAINST THIS TENDER SHALL HAVE TO PURCHASE THE TENDER DOCUMENTS FROM ANY OF OIL S DESIGNATED
More informationPRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE
PROJECT NAME LOCATION PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE INTRODUCTION This specification covers the design, manufacture, and testing of 2-1/2 in. (65 mm) through 18 in. (450 mm) Control
More informationNLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX
/TENDER ENQUIRY NO :ENQ/18-19/002477/MM05(03) /DATE :12/09/2018 /Page - 1 Due Date of Cover-I Opening : 27/09/2018 11:00:00 hrs. IST (Check NLC eproc website for any change in due date of opening.) Note
More informationALTITUDE CONTROL VALVES FOR ONE WAY FLOW
PROJECT NAME LOCATION ALTITUDE CONTROL VALVES FOR ONE WAY FLOW INTRODUCTION This specification covers the design, manufacture, and testing of 2 in. (50 mm) through 36 in. (900 mm) Control Valves PART 1
More informationSKID MOUNTED PORTABLE DIESEL ENGINE DRIVEN CENTRIFUGAL SUMP PUMP SET INSTALLATION& COMMISSIONING 10 INSTALLATION& COMMISSIONING 1 AU
Page:1/1 OIL INDIA LIMITED (AGovt.OfIndiaEnterprise) Tel :03322301657,1658 4, India Exchange Place, Fax :91 33 2230 2596 Kolkata-700001 E-mail:oilcalmn@oilindia.in Tender No.& Date : KID2835L17/08 26.10.2016
More informationMODULATING FLOAT CONTROL VALVE
PROJECT NAME LOCATION MODULATING FLOAT CONTROL VALVE INTRODUCTION This specification covers the design, manufacture, and testing of 2 in. (50 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL
More information: Material Description Quantity UOM
Page : 1 / 6 OIL INDIA LIMITED (A Govt. Of India Enterprise) Tel :033 2230 1657, 1658 4, India Exchange Place, Fax :91 33 2230 2596 Kolkata-700001 E-mail :oilcalmn@cal2.vsnl.net.in ANNEXURE-I Item No./
More information(ISO 9001 CERTIFIED)
(ISO 9001 CERTIFIED) TENDER ENQUIRY FOR PROCUREMENT OF BULLET PROOF JACKET To Subject: TENDER ENQUIRY NO. 04/LP/2018-19/BPJ-2000/WIL-dt. 11-10-2018. You are requested to submit your quotations for the
More informationOil India Limited (A Govt. Of India Enterprise)
Oil India Limited (A Govt. Of India Enterprise) P.O. DULIAJAN 786 602 DIST. DIBRUGARH ASSAM, INDIA FAX : 91 374 2800533 EMAIL : material@oilindia.in WEBSITE : www.oil-india.com TENDER NO. : SDG5613P10/07
More informationBLOC U A-12G BLOC U C-12G
3.3- INJECTOR BLOCKS AND ORIFICES 3.3.1- INJECTOR BLOCKS WITHOUT IGNITION AND WITHOUT FLAME SAFETY BLOC U-0-000-000-00-A-12G...3.3.1.1 BLOC U-0-000-000-00-C-12G...3.3.1.2 Related sections : Burners...3.2
More informationFLOAT CONTROL VALVES
PROJECT NAME LOCATION FLOAT CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 8 in. (200 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL 1. Standard
More informationINVITATION TO BID. (This is not an order.)
Page 1 of 5 SCHEDULE OF EVENTS Event Description 1 / 1 8 inch complete internal diaphragm disc assembly for 100-01 Event Date 8 inch complete internal diaphragm disc assembly for 100-01 No substitutes.
More informationMark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation
Mark 5108 Series Back Pressure Regulating Valves In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. The Mark 5108 is designed to do just that.
More informationInstallation Operation and Maintenance Instructions Model Contents
Contents 1.0 General 1.1 Model Number........................... 2 1.2 Specifications............................ 2 1.3 Dimensions.............................. 3 Repair Kit Materials & Part Numbers........
More informationMark 608BP Series. Pressure Regulators Mark 608BP Gas Pressure Regulators. Balanced Plug Gas Pressure Regulators. Features
Mark 608BP Series Balanced Plug Gas Pressure Regulators The Mark 608BP Balanced Plug Gas Pressure Regulator is the ideal valve for low pressure gas regulation with higher inlet pressures. The selfcontained
More informationLEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology
Technical Bulletin TB-ACV-LFF11RFP_SentryPlus LEAD FREE * LFF11RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology Installed upstream of Reduced Zone Backflow Preventer.
More informationUNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata
UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata- 700106 NOTICE INVITING QUOTATION Sealed Quotations are invited from reputed suppliers
More informationTYPE S RELAY VALVE (Volume booster) Service Manual
TYPE S RELAY VALVE (Volume booster) Service Manual The Type "S" Relay Valve is a pilot operated, 3-way, pneumatic pressure control valve with open exhaust. This large capacity valve receives pressure signals
More informationburner head porting crescents Used on 24", 30" & 36" ranges burner head porting crescents Used on 20" ranges burner head porting slots 3-7/8" 4-1 8"
Peerless Premier eagle - mark royal - modern chef 1388 3-7 8" 8-1/4" crescents 14-3/8" 3-7 8" 1389 Limited quantities available! 1390 8-1/8" 14-1/2" crescents 1391 4-1 2" 4-1/2" Used on 20" ranges 1398
More informationHD Series. Pilot-Operated Regulating Valves. HD Series features & benefits
Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2004 Watson McDaniel Company features & benefits Ductile Iron body for higher pressures Full port strainer
More informationMAHARASHTRA NATURAL GAS LIMITED
Replies to Queries of the Bidders Date: 15.09.2018 SUB: Replies to queries of the bidders against Tender for Procurement of Natural Gas RPD & Turbine Meters with EVC for CGD Network of MNGL, Pune REF:
More informationMaterial Description Quantity UOM
Page : 1 / 8 OIL INDIA LIMITED Fax-91 0361 2643686 (A Govt. of India Enterprise) Email-oilmatpl@oilindia.in Udyan Vihar, Narengi, Guwahati, Assam 10 99070701 BATTERY 12 V 65AH Sealed Maintenance Free (SMF)
More informationSpecifications For Valve Insertion System
Specifications For Valve Insertion System Equipment For Valve Insertion Pipe Sizes: 4 (100mm) Through 12 (300mm) 1.0 SCOPE This specification covers the furnishing, complete EZ Valve insertion system.
More informationTABLE OF CONTENT
Page : 1 of 12 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
More informationRP-1350 Rev. 1. Parts List. Model 441-S Regulator. Parts List. Copyright 1999 Invensys Energy Metering
RP-1350 Rev. 1 Model 441-S Regulator Parts List Model 441-S Regulator Parts List Copyright 1999 Invensys Energy Metering DIAPHRAGM SIZE Nominal Inside Diameter A 7" Diaphragm 9 3 /4" 10" Diaphragm 13 1
More informationF300 Pressure Regulator
F300 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P302 has Internal Relief Valve for Overpressure Protection Ideal for Fix Factor Billing The F300 series pilot operated
More information3. Operating instructions: Minor 200
1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200
More informationPilot Burners. Universal Pilot Burners A /08/12
24/08/12 A124-1 Universal Universal Fit - This pilot burner offers adjustable mounting options, flexible hood orientations and the accessories needed for replacement Universal fittings and compact size
More informationThe Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor
OPERATIONS MANUAL The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor KEY FEATURES Strong, Reliable Ignition & Pilot Flame Rapid Flame Response LED Flame Status Indicator Fully
More informationSeptember 22, 2016 To: All Contractors Re: Boiler Back-Up Fuel Tank System Renovation. Dear Sir:
Mount Allison University Addendum #1 Section 00 91 00 Boiler Back-Up Fuel Tank System Renovation Page 1 of 5 Project # HEAT-15-02 September 22 2016 September 22, 2016 To: All Contractors Re: Boiler Back-Up
More informationDELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING
DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : NOMINAL SIZE MATERIAL MAXIMUM SERVICE PRESSURE 200, 150, 100, 80 & 50NB Cast Iron 12 Bar (175 PSI) THREADED OPENING MOUNTING FACTORY HYDROSTATIC TEST PRESSURE
More informationE8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions
E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions Polypropylene SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser
More informationThe Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor
OPERATIONS MANUAL The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor The CSA approved alternative ignition system delivering safety, reliability and versatility. KEY FEATURES Unique
More informationSPECIFICATIONS FOR A SINGLE-COLOR, SINGLE LINE ROADWAY PAINT MARKING MACHINE. HEAVY DUTY MODEL C Part Number: PO-HDC
SPECIFICATIONS FOR A SINGLE-COLOR, SINGLE LINE ROADWAY PAINT MARKING MACHINE HEAVY DUTY MODEL C Part Number: GENERAL These specifications are to cover the minimum specifications of a single line, single
More informationSPECIFICATIONS FOR MOTOR OPERATED VALVES
Doc No: 254625-300-SP-INT-004 Rev: B Page 1 of 11 SPECIFICATIONS FOR MOTOR OPERATED VALVES Hindustan Petroleum Corporation Ltd Visakha Dispatch Station VR-ATP Area, Naval Base Post Visakhapatnam - 530
More informationNIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt
Annexure-1 NIT No.:-/WEX/MCR/HYD. PRESS/2-303/21-12/Dt.02.03.22 Name of work:-retrofitting of new hydraulic power pack on 63 Ton Hydraulic Press, Plan No.1/2-303 SCOPE OF SUPPLY AND WORK: 1.0 Purpose of
More informationBharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU. INDIA CAPITAL EQUIPMENT/ MATERIALS MANAGEMENT
An ISO 9001 Company ENQUIRY Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU. INDIA CAPITAL EQUIPMENT/ MATERIALS MANAGEMENT NOTICE INVITING TENDER Phone:
More informationKalahari & GlowPlus. Kalahari and GlowPlus Heaters Issue 1. Nov 09
Kalahari & GlowPlus Kalahari Room Heater Natural Gas Models: Kalahari-18-NG and Kalahari-25-NG Kalahari Room Heater Natural Gas Item Description Part No. 1 Front Cover Assembly 05-27715- 2 Filter Assembly
More informationJanuary 2016 GLOBE VALVES MIXING & DIVERTING SERIES 8600 MODEL Previously manufactured by Dezurik and Honeywell
786.89 January 2016 GLOBE VALVES MIXING & DIVERTING SERIES 8600 MODEL 8900 Previously manufactured by Dezurik and Honeywell Description: The Nor East Series 8600 (mixing) and Series 8900 (diverting) cage
More informationSECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES
SECTION 33 12 16.05 REDUCING VALVES AND ACCESSORIES PART 1 - GENERAL 1.1 THE REQUIREMENT A. The Electronic Actuated Pressure Reducing Valve (PRV) shall maintain a constant downstream pressure regardless
More informationTECHNICAL BID T 3627
TECHNICAL BID T 3627 Supply of Mechanical Measuring Instruments for TMD-II OF UKAI TPS. Due on At 3.30 P.M. (if Possible) EMD paid YES / NO EMD D. D. No. Date : OR SSI / NSIC Certification Number : Duly
More informationFlow Limit Safety Shutoff Valves Model 1
Flow Limit Safety Shutoff Valves Model 1 Model 1 Series flow limit safety shutoff valves automatically shutoff all flow from the cylinder when flow exceeds a factory preset level. The Model 1 is normally
More informationSPECIFICATIONS FOR A SINGLE-COLOR, SINGLE LINE ROADWAY PAINT MARKING MACHINE
SPECIFICATIONS FOR A SINGLE-COLOR, SINGLE LINE ROADWAY PAINT MARKING MACHINE HEAVY DUTY MODEL C Stainless Steel Tank, Non-Bleeder/Flush Part Number: GENERAL These specifications are to cover the minimum
More informationA. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.
1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall
More informationInstrument Pressure Range Standard Body psi max. High Flow Rate Body psi max.
Basic Information All ESP Types Overall Size Length............................ 12 3/4-in. Max. Diameter All Piston Type...................... 2 1/4-in. Max. 2-in. Diaphragm..................... 2 7/8-in.
More informationSupply of Batteries
Supply of Batteries 207-8 SUPPLY OF BATTERIES OF VARIOUS RATINGS E-PROCUREMENT (REVERSE AUCTION) NIT No: 07/ 207-8 Name of the work Supply of Batteries to our Branches / Offices /ATM Completion Time EMD
More informationA. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.
SECTION 220523 - PLUMBING VALVES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Ball valves. 2. Butterfly valves. 3. Swing check valves. 4. Spring loaded check valves. 5. Water pressure reducing
More informationSection V DC Nickel Cadmium Alkaline BATTERY
Section - 7 TECHNICAL SPECIFICATION OF 110V DC Nickel Cadmium Alkaline BATTERY TECHNICAL SPECIFICATIONS & REQUIREMENTS OF 110V DC Nickel Cadmium Alkaline Battery 7. 1 GENERAL This section of the document
More informationشركة كهرباء محافظة القدس المساهمة المحدودة
Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories
More informationOil India Limited (A Govt. of India Enterprise) P.O. Duliajan , Assam
Oil India Limited (A Govt. of India Enterprise) P.O. Duliajan 786602, Assam Telephone No. (91-374) 2800491 Fax No: (91-374) 2800533 Email: matdmmfd@oilindia.in ; erp_mm@oilindia.in Tender No. & Date :
More informationTECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48
DOROT PLASTIC VALVES PRINCIPLE OF OPERATION -Way Control System The main valve is controlled by a manually, electrically or pressure actuated selector that: (1) Introduces the upstream pressure or an external
More informationProduct overview. Technical data
VALVES & CONTROLS ANDERSON GREENWOOD BLANKETING SYSTEMS The Complete Blanketing and Safety Valve System! Product overview Pad Valves Anderson Greenwood is a world leader in tank protection and blanketing.
More information4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.
SHEET 1 OF 5 1.0 GENERAL & SCOPE 1.1 This specification covers the design, material, construction features, manufacture, inspection & testing, Painting and packing requirements of Spring Loaded Bypass
More informationinstrumentation ball valves
7G Series 2 and 3-way Ball Valves Multi-directional Flow HOKE Inc. 405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303 Phone (864) 574-7966 Fax (864) 587-5608 www.hoke.com sales@hoke.com instrumentation
More informationTECHNICAL SPECIFICATIONS
TENDER DOCUMENT TENDER NO.: DLI/C&E/WI-675/275 FOR Tender for Design, Engineering, Supply and Supervision of installation, testing & commissioning of Cable Reeling Drum with Composite Flexible Trailing
More informationOil India Limited (A Govt. Of India Enterprise)
Oil India Limited (A Govt. Of India Enterprise) P.O. DULIAJAN 786 602 DIST. DIBRUGARH ASSAM, INDIA FAX : 91 374 2800533 EMAIL : material@oilindia.in WEBSITE : www.oil-india.com TENDER NO. : SDG3271P10/07
More informationSTORES/EASTERN RLY Tender Document For Tender No : Due Date/Time: 14/03/ :30
STORES/EASTERN RLY, for & on behalf of The President of India, Invites electronic tenders for the following items. Tender No : 04156049 Evaluation Criteria : Total Value Wise Tender Doc. Cost (INR) : 2500.00
More informationS P R AY E R VA L V E S AND C O N T ROL S C AT A L OG
Q UA L I T Y VA LV E S A N D C O N T R O L S. TO D AY A N D TO M O R R O W. Texas Industrial Remcor, Inc. CATALOG NO. 33 The new RC2 control system: Ensures no potential leaks in the tractor cab when using
More informationPilot Burners. Universal Pilot Burners A /08/12
24/08/12 A124-1 Universal Universal Fit - This pilot burner offers adjustable mounting options, flexible hood orientations and the accessories needed for replacement Universal fittings and compact size
More informationPRESSURE REDUCING CONTROL VALVE
PRESSURE REDUCING CONTROL VALVE 06/08 Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) X P/L Standard Components 1 Main
More informationIMPORTANT NOTE (C) SENIOR ADVISER(CONTRACT & PURCHASE), OIL INDIA LIMITED, 5, SIKANDRA ROAD, NEW DELHI
IMPORTANT NOTE BID DOCUMENT HAS BEEN DISPLAYED TO UNDERSTAND THE REQUIREMENT ONLY. PARTIES INTERESTED TO PARTICIPATE AGAINST THIS TENDER SHALL HAVE TO PURCHASE THE TENDER DOCUMENTS FROM ANY OF OIL S DESIGNATED
More informationPressure reducing valves
Pressure reducing valves Pilot Operated 25 Series The Spirax Sarco 25-Series regulators are a versatile family of self-acting pressure regulators with control pilots and interchangeable main valves for
More informationNLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX
NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX Dr. Rajendra Prasad Road,Block-27,Neyveli-607807.Tamilnadu,India.
More informationDeluge Valves. Model 68 DE\ HRV-MR. Hydraulically Actuated, Anti-Columning, Manual-Reset Deluge Valve. Dorot Fire Protection Division
Fire Protection Div. Dorot Fire Protection Division Deluge Valves Model 68 DE\ HRV-MR Hydraulically Actuated, Anti-Columning, Manual-Reset Deluge Valve Certification & compliance by design ANSI FCI 70-
More informationCAST IRON VALVES PRESSURE REDUCING VALVES SERIES
CAST IRON VALVES PRESSURE REDUCING VALVES SERIES NETAFIM CAST IRON VALVES PRESSURE REDUCING VALVES INLINE 0-600MM ANGLE 0-150MM SPECIFICATIONS Manufactured to ISO 9001 Available Valve sizes INLINE Flanged
More informationMustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.
PRESSURE REDUCING CONTROL VALVE 02/09 Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) P/L Standard Components 1 Main Valve
More informationDO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.
428 Jones Boulevard Limerick Airport Business Center Pottstown, PA 19464 Phone: (610)495-5131 ax: (610)495-5134 www.watsonmcdaniel.com PAGE 28 INSTRUCTION PART NO. 2315400 C.R.3500 REV. 10 SIZE C B CENTER
More informationHeating and Gas Installations - December 2014
This is an example of good practice maintenance specifications. It is not exhaustive and should only be used to assist with facilities management or specification of a maintenance contract. Emergency Gas
More informationMODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions
MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions DESCRIPTION: This valve is the basic component used for most
More informationTECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)
Flow Control 500a DESCRIPTION The Viking 1-1/2 is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The can be used to facilitate manual or automatic on/off
More informationSAMPLE CYLINDERS. Sample Cylinders & Accessories. Spun End Cylinders. Ultra-Seal Constant Pressure Cylinders. VP Series Cylinder Valves
SAMPLE CYLINDERS T H E S O L U T I O N F O R G A S S A M P L E S T O R A G E Sample Cylinders & Accessories ISO 9001:2008 Certified Quality System Spun End Cylinders Ultra-Seal Constant Pressure Cylinders
More informationSERIES 20/20S/20H/ 20HS PILOT
SERIES 20/20S/20H/ 20HS PILOT Installation, Operation & Maintenance Scope This manual provides installation, operation and maintenance instructions for the Series 20/20S/20H/20HS Pilots. The manual is
More informationMULTIPOSITION AIR CYLINDER
MULTIPOSITION AIR CYLINDER CAST ALUMINUM FOUR-POSITION - ALL AIR SERVICE INFORMATION MOUNTING! Devices should be mounted and positioned in such a manner that they cannot be accidentally operated. INSTALLATION
More informationSPECIFICATIONS FOR A HEAVY DUTY C W/ TRACTION
SPECIFICATIONS FOR A HEAVY DUTY C W/ TRACTION Stainless Steel Tank, Non-Bleeder/Flush Part Number: PO- (air actuated traction drive) Part Number: PO-Hydro-SS (hydrostatic wheel drive) GENERAL These specifications
More informationTECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)
1 of 9 1. DESCRIPTION The Viking 2 (DN50) is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction sprinkler
More informationTECHNICAL DATA. Q= C v P S
1 of 9 1. DESCRIPTION The Viking Model E-1 Deluge Valve is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction
More informationModel 5400 / 5450 Control Valve
Model 5400 / 5450 Control Valve The Model 5400 (open yoke) and Model 5450 (closecoupled) control valves are designed to meet the high pressure and erosive applications common to the oil and gas industry.
More informationGUJARAT NARMADA VALLEY FERTILIZERS COMPANY LIMITED MTPA PAC PROJECT SECTION 6 ANNEXURE 4.7 SPARES, INSP AGENCY & DOCUMENTATION
A. SPARE PARTS Outline for the supply of Spare Parts for various items is as elaborated below: A-1 MACHINERY Commissioning spares will be as per the manufacturer s recommendations. For 2 years of normal
More informationRETSCO, Ltd. Shear Relief Valve Catalog. When Quality Counts, Count on RETSCO, Ltd. Check out our website:
RETSCO, Ltd. When Quality Counts, Count on RETSCO, Ltd Shear Relief Valve Catalog 3" 2" Check out our website: www.retscoinc.com Quick Reference for Top Level Assembly Part Number ASSEMBLY PART NUMBER
More informationMODEL DX Pneumatic Diaphragm Actuator
MODEL DX Pneumatic Diaphragm Actuator FEATURES Flexibility Model DX actuators can be adapted to operate valves from any manufacturer (interface information is required) and can be assembled in single or
More informationCrosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure.
CROSBY Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure. Features The balanced piston design offsets the effects of variable back pressure on valve set
More informationPRESSURE REDUCING VALVE
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING VALVE with LOW-FLOW BY-PASS FEATURE Main Line valve
More informationSection VI: List of Requirements (REVISED)
As per Technical Specifications attached in Section VII Date: 18/06/2018 of Electrical Items With reference to the above tender, the following Corrigendum may kindly be noted against the Section VI, Section
More informationDeluge Pressure Reducing Valves. Model 68 DE\ RCL\ PR. Electrically Actuated, Manual-Reset, Pressure Reducing, Deluge Valve
Fire Protection Div. Dorot Fire Protection Division Deluge Pressure Reducing Valves Model 68 DE\ RCL\ PR Electrically Actuated, Manual-Reset, Pressure Reducing, Deluge Valve Certification & compliance
More information