1 First Quality Solutions Turbine Inspection Reports

2 VISUAL EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: S1 Component: Turbine Components WO: Code: N/A Material: Varied See below Preparation: Blasted Temperature: 70 F Weld Types: N/A Acceptance Standards: Cust. FQS Procedure: 002-Rev. 5 Visual Aids: Flashlight, mirror, ruler Technique: Direct Visual Component Acc. Rej. Remarks/Indications A LP Rotor X See below B LP Rotor X See below Diaphragm Assemblies X See below Shells & Casings* X See below Main Steam Stop Valve Assemblies X See below Windage Covers X See below Bolting & Studs X See below Generator Fan Blades X See below Summary of Inspection Performed: The components listed above were visually inspected for wear and general condition. In addition to the preliminary visual inspection each component received additional NDE inspections as indicated below, as directed by plant engineering. Technique sheets for each inspection performed can be found within. A LP Rotor WFMT Inspection, PT Inspection, UT Inspection B LP Rotor WFMT Inspection, PT Inspection, UT Inspection Diaphragm Assemblies WFMT Inspection Shells & Casings* WFMT Inspection on selected items Windage Covers Visible dye PT Inspection Bolting & Studs UT Inspection Generator Fan Blades Visible dye PT Inspection * The shells and casing inspected are as follows: A lower & upper shell B lower & upper shell LPA upper casing LPB upper casing Packing heads Packing Extension Cones Examiner: Gordon Austin Level: II Date: 12/20/2010 Examiner: Michael Schantz Level: II Date: 12/20/2010

3 A LP Rotor Visual Inspection The A LP Rotor was removed, blasted, and inspected at selected locations for damage and general condition. Technique sheets can be found within for the magnetic particle, liquid penetrant, and ultrasonic inspections. Listed below are the findings of the visual inspection. Wheels/Bolt holes Acceptable, no findings to report Dove Tails & Pins Acceptable, no findings to report Buckets o Generator End L-0 Minor impact damage noted at outer 18 on buckets 16, 18, 27, 49, 53, 54, 55, 56, 88, 89, 104, 105, & 106. L-1 Light erosion on the trailing edge of buckets & 56 88; minor mechanical gouging noted on buckets 38 & 77. L-2 Minor mechanical gouges noted on buckets 11, 16, 47, & 62. L-3 Acceptable, no findings to report. L-4 Acceptable, no findings to report. L-5 Minor mechanical gouging on the outside 2 typical of all buckets. o Turbine End L-0 Minor impact damage noted at out 18 on buckets 3, 4, 7, 8, 9, 26, 44, 49, 68, 69, 70, 106, 107, 108, 109, & 110; Damage noted on bucket 66, 6 from outside of bucket (sliver solder chipped and erosion shield pulling away from bucket). L-1 Light erosion on the trailing edge typical of each bucket. L-2 Light erosion on the trailing edge typical of each bucket. L-3 Minor mechanical gouging noted at buckets 10, 14, 22, & 35. L-4 Acceptable, no findings to report. L-5 Minor to moderate mechanical gouging on the outside 2 typical of all buckets. Tie Wires o Generator End L-0 Acceptable, no findings to report o Turbine End L-0 Silver solder damaged at buckets 19, 33 & 47. Stellite Erosion Shields o Generator End L-0 Minor porosity noted in silver solder on buckets 15 & 34. o Turbine End L-0 Silver solder chipped and erosion shield pulling away from bucket 66. B LP Rotor Visual Inspection The A LP Rotor was removed, blasted, and inspected at selected locations for damage and general condition. Technique sheets can be found within for the magnetic particle, liquid penetrant, and ultrasonic inspections. Listed below are the findings of the visual inspection. Wheels/Bolt holes Acceptable, no findings to report. Dove Tails & Pins Acceptable, no findings to report. Buckets o Generator End L-0 Minor impact damage noted at outer 12 on buckets 44, 47, 56, 57, 58, 59, 69, 70, 71, & 72. L-1 Acceptable, no findings to report.

4 L-2 Acceptable, no findings to report. L-3 Acceptable, no findings to report. L-4 Acceptable, no findings to report. L-5 Acceptable, no findings to report. o Turbine End L-0 Minor impact damage noted at outer 18 on buckets 4, 7, 8, 9, 22, 27, 38, 49, 56, 60, 70, 71, 72, 94, 97, 104, 107, & 108. L-1 Acceptable, no findings to report. L-2 Acceptable, no findings to report. L-3 Acceptable, no findings to report. L-4 Acceptable, no findings to report. L-5 Acceptable, no findings to report. Tie Wires o Generator End L-0 Acceptable, no findings to report. o Turbine End L-0 Acceptable, no findings to report. Stellite Erosion Shields o Generator End L-0 Acceptable, no findings to report. o Turbine End L-0 Acceptable, no findings to report. Diaphragm Assemblies The diaphragm assemblies 22 through 25 stages in both the A&B low-pressure sections were removed, cleaned, visually inspected, and inspected utilizing the wet fluorescent magnetic particle method. All deficiencies noted on the diaphragm assemblies were marked and recorded. The list below will provide the identifications of each diaphragm inspected. Please refer to the technique sheets for the results of the visual inspection and magnetic particle inspection. General view of diaphragm staging area

5 Shells & Casings A Shell Lower o Minor multiple cracking was noted on the horizontal joint between the14 th and 16 th stage areas on both the left and right sides. o Separation was noted, at the bolted connection of the hood extension and casing shell on turbine end left side. o Cracking was noted in the spacer blocks welds at the 18 th stage turbine end left side. o Erosion noted on the N3 packing case on the turbine end. General view of A Shell - Lower A Shell Upper o #3 door on the left side has 360º cracking on the interior weld. o #3 door on the right side has 360º cracking on the interior weld and (3) 1 cracks in the exterior weld. The door insert also has a 1 crack on the exterior. General view of A Shell - Upper

6 B Shell Lower o Minor multiple cracking noted at the horizontal joint between the14 th and 16 th stage areas on both the left and right sides. o LP Condenser piping cracked on the generator end, right side. General view of B Shell - Lower B Shell Upper o #3 door on the left side has 360º cracking on the interior weld. o #3 door on the right side has 360º cracking on the interior weld and 3 crack in the exterior weld. o #2 door on the left side has a 1 void in the exterior weld. General view of B Shell - Upper

7 LPA Upper Casing o 1 indication noted on the generator end, left side. LPB Upper Casing o Acceptable, no findings to report General view of LPA & LPB Upper Casings Packing Heads o N4 Acceptable, no findings to report o N5 Acceptable, no findings to report o N6 Acceptable, no findings to report o N7 Acceptable, no findings to report Packing Cone Extensions o The N4, N5, N6, & N7 packing cone extensions were inspected at the bolting end utilizing the magnetic particle method and were found to acceptable, however the bolting ends were damaged during disassembly and have extremely rough and sharp edges, a recommendation for repair was made.

8 Windage Covers A, B, & C Windage covers were inspected utilizing dye penetrant and visual inspection techniques, with no findings to report Windage covers A & B Windage covers C

9 Bolting & Studs The following bolting and studs were inspected visually and utilizing ultrasonic inspection techniques: A & B Coupling studs Acceptable, no findings to note Crossover vertical joint studs Acceptable, no findings to note HP turbine end crossover studs Acceptable, no findings to note Inner shell outside bolts Acceptable, no findings to note Steam chest studs Acceptable, no findings to note Stop valve bonnet studs Acceptable, no findings to note Upper control valve studs Acceptable, no findings to note Generator Fan Blades Fan blades (24) for the collector and turbine ends were examined utilizing dye penetrant and visual inspection techniques. Generator fan blades

10

11

12 LIQUID PENETRANT EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: S1 Component: A LP Rotor WO: Code: N/A Material: Silver Solder Preparation: Blasted Temperature: 65 F Visible: Yes Fluorescent: N/A Black Light Int: N/A Solvent Removable: Yes Cleaner Type: SKC-S Batch No: 06K02K Water Washable: N/A Penetrant Type: SKL-SP1 Batch No: 05L01K FQS Procedure: 003 Developer Type: SKD-S2 Batch No: 04G11K Component Acc. Rej. Remarks/Indications Generator End L-0 Tie Wires X No indications noted Turbine End L-0 Tie Wires X 3 indications (Buckets 19, 33, & 47) G.E. - Selected Stellite Erosion Shields X 5 indications (B. 14, 15, 22, 34, 56) T.E. Selected Stellite Erosion Shields X 2 indications (Buckets 49 & 66) Summary of Inspection Performed: Visible red dye liquid penetrant inspection was performed on the outer tie wires and the stellite erosion shields of the L-0 buckets at both the generator and turbine ends of the A LP Rotor. Results of each inspection can be found below. View of typical tie wire Examiner: Mike Schantz Level: II Date: 12/20/2010 Examiner: Josh Porter Level: II Date: 12/20/2010

13 ULTRASONIC EXAMINATION REPORT PAGE 1 Customer: Sample Turbine Outage PO No: Report No: S1 Component: A LP Rotor Dove Tail Pins WO No: Drawing: N/A Material: C/S Prep: Blasted Test: 73 Procedure: 005 Code: N/A Instrument: Manufacturer: Model: Serial Number: Material Velocity: Panametrics Epoch III N/A Range: Gain: Reject: Scan Sensitivity: Sweep Delay: Varied 48 db N/A + 2 db N/A Transducer: Manufacturer: Frequency: Wave Mode: Size & Shape: Angle: KBA 2.25 Long. 1/4 Round Normal Couplant: Type: Ultragel Batch Number: Calibration: Cal Block No.: Part Thickness: CRT Cal Inches: Major Scrn. Div.: N/A Varied Varied Varied Cal. Times: Initial: 07:30 Final: 13:00 Scanning: 100% Weld: 100% Base Mat.: Parallel to Weld: Trans. To Weld: N/A N/A N/A N/A Summary of Inspection Performed: A UT inspection was performed on the dove tail pins on the generator and turbine ends of the double flow rotor. Three (3) rows of 114 pins were examined on both sides of the rotor; all pins were found acceptable, with no cracking noted.

14 ULTRASONIC EXAMINATION REPORT PAGE 2 Item/Weld No. A R Remarks/Indications Dove tail pins (Generator End) X Three (3) rows of 114 pins examined (Acceptable - No cracking noted) Dove tail pins (Turbine End) X Three (3) rows of 114 pins examined (Acceptable - No cracking noted) Sketch/Comments: Examiner: Gordon Austin Level: II Date: 12/22/2010 Examiner: Level: Date:

15 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: S1 Component: B LP Rotor WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 65 F Visible: N/A Fluorescent: Yes Magnetism: Long. Particles: Wet 20B Black Light Int: >1000uw/cm2 Batch No: 05A013 Equipment: Magnaflux Model No: M-500/Y-6 Serial No: FQS-001/FQS-009 Current: A/C Ampere Turns: 800 Prod Spacing: N/A Component Acc. Rej. Remarks/Indications Generator End L-0 X See below L-1 X No indications noted L-2 X No indications noted L-3 X No indications noted L-4 X No indications noted L-5 X No indications noted Turbine End L-0 X See below L-1 X No indications noted L-2 X No indications noted L-3 X No indications noted L-4 X No indications noted L-5 X No indications noted Summary of Inspection Performed: The unit 5 B LP Rotor was removed, blasted, and magnetic particle inspected for cracking. The B LP Rotor was replaced during the 2006 maintenance outage, and remains in good general condition, however, several indications were noted on the turbine and generator end L-0 buckets. Multiple coil setups and Y-6 magnetism were utilized to complete the inspection. The results of the MT inspection can be seen below. B LP Rotor Examiner: Gordon Austin Level: II Date: 12/28/2010 Examiner: Michael Schantz Level: II Date: 12/28/2010

16 LIQUID PENETRANT EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: S1 Component: B LP Rotor WO: Code: N/A Material: Silver Solder Preparation: Blasted Temperature: 65 F Visible: Yes Fluorescent: N/A Black Light Int: N/A Solvent Removable: Yes Cleaner Type: SKC-S Batch No: 06K02K Water Washable: N/A Penetrant Type: SKL-SP1 Batch No: 05L01K FQS Procedure: 003 Developer Type: SKD-S2 Batch No: 04G11K Component Acc. Rej. Remarks/Indications Generator End L-0 Tie Wires X No indications noted Turbine End L-0 Tie Wires X No indications noted G.E. - Selected Stellite Erosion Shields X 2 indications (Buckets 27 & 40) T.E. Selected Stellite Erosion Shields X No indications noted Generator End L-0 Weld Repairs Bucket 69 X No indications noted Bucket 72 X No indications noted Summary of Inspection Performed: Visible red dye liquid penetrant inspection was performed on the outer tie wires and the stellite erosion shields of the L-0 buckets at both the generator and turbine ends of the B LP Rotor, as well as two (2) weld repairs requested by plant engineering. Any findings from each inspection can be found below. View of typical tie wire Examiner: Mike Schantz Level: II Date: 12/22/2010 Examiner: Josh Porter Level: II Date: 12/22/2010

17 ULTRASONIC EXAMINATION REPORT PAGE 1 Customer: Sample Turbine Outage PO No: Report No: S1 Component: B LP Rotor Dove Tail Pins WO No: Drawing: N/A Material: C/S Prep: Blasted Test: 73 Procedure: 005 Code: N/A Instrument: Manufacturer: Model: Serial Number: Material Velocity: Panametrics Epoch III N/A Range: Gain: Reject: Scan Sensitivity: Sweep Delay: Varied 48 db N/A + 2 db N/A Transducer: Manufacturer: Frequency: Wave Mode: Size & Shape: Angle: KBA 2.25 Long. 1/4 Round Normal Couplant: Type: Ultragel Batch Number: Calibration: Cal Block No.: Part Thickness: CRT Cal Inches: Major Scrn. Div.: N/A Varied Varied Varied Cal. Times: Initial: 07:30 Final: 13:00 Scanning: 100% Weld: 100% Base Mat.: Parallel to Weld: Trans. To Weld: N/A N/A N/A N/A Summary of Inspection Performed: A UT inspection was performed on the dove tail pins on the generator and turbine ends of the double flow rotor. Three (3) rows of 114 pins were examined on both sides of the rotor; all pins were found acceptable, with no cracking noted.

18 ULTRASONIC EXAMINATION REPORT PAGE 2 Item/Weld No. A R Remarks/Indications Dove tail pins (Generator End) X Three (3) rows of 114 pins examined (Acceptable - No cracking noted) Dove tail pins (Turbine End) X Three (3) rows of 114 pins examined (Acceptable - No cracking noted) Sketch/Comments: Examiner: Gordon Austin Level: II Date: 12/22/2010 Examiner: Level: Date:

19 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: GE LPA 22 Upper WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 65 Visible: No Fluorescent: Yes Magnetism: Long. Particles: Wet 20B Black Light Int: >1000 um/cm 2 Batch No: 09G12K Equipment: Magnaflux Model No: P-90 Serial No: FQS-1 Current: A/C Ampere Turns: 800 Prod Spacing: N/A Position of Inspection Findings: Typical view of diaphragm blades counted left to right while Blade # 1 facing discharge side Blade # 39 Left Joint Right Joint Summary of Inspection Results: Discharge Side F.O.D. (Foreign Object Damage) noted on blades 1 39 Intake Side No findings to report Horizontal Joints 1/32 crack noted at the left horizontal joint Examiner: Gordon Austin Level: II Date: 12/26/2010 Examiner: Josh Porter Level: II Date: 12/26/2010

20 Example of typical F.O.D. noted on blades /32 crack noted in left horizontal joint

21 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: GE LPA 22 Lower WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 65 Visible: No Fluorescent: Yes Magnetism: Long. Particles: Wet 14AM Black Light Int: >1000 um/cm 2 Batch No: 09G12K Equipment: Magnaflux Model No: P-90 Serial No: FQS-1 Current: A/C Ampere Turns: 800 Prod Spacing: N/A Position of Inspection Findings: Typical view of diaphragm blades counted left to right while Blade # 1 facing discharge side Blade # 39 Left Joint Right Joint Summary of Inspection Results: Discharge Side Moderate erosion damage noted at entire side (marked with yellow hash marks) Steam seal damaged at blades edge rolled over Steam cuts/erosion noted throughout the outer ring 3/8 crack noted at wire tie post weld Intake Side Moderate erosion damage noted at entire side (marked with yellow hash marks) Horizontal Joints Steam cuts/erosion noted at the right horizontal joint corner Steam cuts/erosion noted at the left horizontal joint corner Steam cuts/erosion noted at inner ring 1/8 crack noted on left horizontal joint Examiner: Jared Spada Level: II Date: 12/26/2010 Examiner: Brandon Mayne Level: II Date: 12/26/2010

22 Example of minor erosion noted at the entire discharge side and outer ring Example of steam seal damage noted from blades 1 31

23 3/8 crack noted at wire tie post weld Example of minor erosion noted at the entire intake side

24 Minor erosion noted at left horizontal joint Minor erosion noted at right horizontal joint

25 Minor erosion noted at inner ring 1/8 crack noted at left horizontal joint

26 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: TE LPA 22 Upper WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 65 Visible: No Fluorescent: Yes Magnetism: Long. Particles: Wet 14AM Black Light Int: >1000 um/cm 2 Batch No: 09G12K Equipment: Magnaflux Model No: Y-6 Serial No: FQS-9 Current: A/C Ampere Turns: N/A Prod Spacing: 4 Position of Inspection Findings: Typical view of diaphragm blades counted left to right while Blade # 1 facing discharge side Blade # 44 Left Joint Right Joint Summary of Inspection Results: Discharge Side Minor F.O.D. noted on all blades Steam seal damage noted from blades edges rolled over Blades bent/damaged from blades 3-7, 10-16, & Intake Side No findings to report Horizontal Joints Minor gouging noted at the left horizontal joint Minor gouging noted at the right horizontal joint Examiner: Jared Spada Level: II Date: 12/26/2010 Examiner: Brandon Mayne Level: II Date: 12/26/2010

27 Example of minor F.O.D. as noted on all blades Example of steam seal damage as seen from blades 1 32

28 Example of blade damage as seen on blades 3-7, 10-16, and General view of intake side of upper stage 22 diaphragm no findings to report

29 Minor gouging on the left horizontal joint corner Minor gouging on the right horizontal joint corner

30 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Outage Report PO: Report No: N/A Component: GE LPA 23 Upper WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 65 Visible: No Fluorescent: Yes Magnetism: Long. Particles: Wet 14AM Black Light Int: >1000 um/cm 2 Batch No: 09G12K Equipment: Magnaflux Model No: Y-6 Serial No: FQS-9 Current: A/C Ampere Turns: N/A Prod Spacing: 4 Position of Inspection Findings: Typical view of diaphragm blades counted left to right while Blade # 1 facing discharge side Blade # 39 Left Joint Right Joint Summary of Inspection Results: Discharge Side Minor F.O.D. noted on all blades Steam seal damage noted from blades edges rolled over Intake Side No findings to report Horizontal Joints Minor gouging noted at the left horizontal joint Minor gouging noted at the right horizontal joint Examiner: Jared Spada Level: II Date: 12/26/2010 Examiner: Brandon Mayne Level: II Date: 12/26/2010

31 Example of minor F.O.D. as noted on all blades Example of steam seal damage as seen from blades 1 27

32 General view of intake side of upper stage 23 diaphragm no findings to report Minor gouging on the left horizontal joint corner

33 Minor gouging on the right horizontal joint corner

34 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: A Shell lower WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 60º Visible: No Fluorescent: Yes Magnetism: Longitudinal Particles: Wet Suspension: Oil Batch No: 09F06K Equipment: Magnaflux Model No: Y-6 Serial No: FQS - 13 Current: A.C. Ampere Turns: N/A Prod Spacing: 4 Component Acc. Rej. Remarks/Indications A Shell lower X See below Comments: Minor multiple cracking was noted on the horizontal joint between the14 th and 16 th stage areas on both the left and right sides. Separation was noted, at the bolted connection of the hood extension and casing shell on turbine end left side. Cracking was noted in the spacer blocks welds at the 18 th stage turbine end left side. Erosion noted on the N3 packing case on the turbine end. Note: All noted cracks were excavated and verified for removal. All weld repairs were verified via magnetic particle inspection for quality, no further action is required. Examiner: Mike Schantz Level: II Date: 12/24/10 Examiner: Gordon Austin Level: II Date: 12/24/10

35 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: A Shell upper WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 60º Visible: No Fluorescent: Yes Magnetism: Longitudinal Particles: Wet Suspension: Oil Batch No: 09F06K Equipment: Magnaflux Model No: Y-6 Serial No: FQS - 13 Current: A.C. Ampere Turns: N/A Prod Spacing: 4 Component Acc. Rej. Remarks/Indications A Shell upper X See below Comments: #3 door on the left side has 360º cracking on the interior weld. #3 door on the right side has 360º cracking on the interior weld and (3) 1 cracks in the exterior weld. The door insert also has a 1 crack on the exterior. Note: All noted cracks were excavated and verified for removal. All weld repairs were verified via magnetic particle inspection for quality, no further action is required. Examiner: Mike Schantz Level: II Date: 12/24/10 Examiner: Gordon Austin Level: II Date: 12/24/10

36 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: B Shell lower WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 60º Visible: No Fluorescent: Yes Magnetism: Longitudinal Particles: Wet Suspension: Oil Batch No: 09F06K Equipment: Magnaflux Model No: Y-6 Serial No: FQS - 13 Current: A.C. Ampere Turns: N/A Prod Spacing: 4 Component Acc. Rej. Remarks/Indications B Shell lower X See below Comments: Minor multiple cracking noted at the horizontal joint between the14 th and 16 th stage areas on both the left and right sides. LP Condenser piping cracked on the generator end, right side. Note: All noted cracks were excavated and verified for removal. All weld repairs were verified via magnetic particle inspection for quality, no further action is required. Examiner: Mike Schantz Level: II Date: 12/24/10 Examiner: Gordon Austin Level: II Date: 12/24/10

37 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: B Shell upper WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 60º Visible: No Fluorescent: Yes Magnetism: Longitudinal Particles: Wet Suspension: Oil Batch No: 09F06K Equipment: Magnaflux Model No: Y-6 Serial No: FQS - 13 Current: A.C. Ampere Turns: N/A Prod Spacing: 4 Component Acc. Rej. Remarks/Indications B Shell upper X See below Comments: #3 door on the left side has 360º cracking on the interior weld. #3 door on the right side has 360º cracking on the interior weld and 3 crack in the exterior weld. #2 door on the left side has a 1 void in the exterior weld. Note: All noted cracks were excavated and verified for removal. All weld repairs were verified via magnetic particle inspection for quality, no further action is required. Examiner: Mike Schantz Level: II Date: 12/24/10 Examiner: Gordon Austin Level: II Date: 12/24/10

38 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: LPA & LPB upper casing WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 60º Visible: No Fluorescent: Yes Magnetism: Longitudinal Particles: Wet Suspension: Oil Batch No: 09F06K Equipment: Magnaflux Model No: Y-6 Serial No: FQS - 13 Current: A.C. Ampere Turns: N/A Prod Spacing: 4 Component Acc. Rej. Remarks/Indications LPA upper casing X 1 ind. On left side GE LPB upper casing X No indications noted Comments: Note: 1 indication on LPA excavated to 1/16 depth, and verified for indication removal. No weld repair is required and no further action is needed. Examiner: Mike Schantz Level: II Date: 12/24/10 Examiner: Gordon Austin Level: II Date: 12/24/10

39 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: Upper Packing Heads WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 60º Visible: No Fluorescent: Yes Magnetism: Longitudinal Particles: Wet Suspension: Oil Batch No: 09F06K Equipment: Magnaflux Model No: Y-6 Serial No: FQS - 13 Current: A.C. Ampere Turns: N/A Prod Spacing: 4 Component Acc. Rej. Remarks/Indications N4 Packing casing - upper X No indications noted N5 Packing casing - upper X No indications noted N6 Packing casing - upper X No indications noted N7 Packing casing - upper X No indications noted Comments: Examiner: Jared Spada Level: II Date: Examiner: Level: Date:

40 MAGNETIC PARTICLE EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: Packing Cone Extensions WO: Code: N/A Material: C/S Preparation: Blasted Temperature: 60º Visible: No Fluorescent: Yes Magnetism: Longitudinal Particles: Wet Suspension: Oil Batch No: 09F06K Equipment: Magnaflux Model No: Y-6 Serial No: FQS - 13 Current: A.C. Ampere Turns: N/A Prod Spacing: 4 Component Acc. Rej. Remarks/Indications Packing Cone Extensions X See below Comments: Bolting ends were damaged during disassembly and have extremely rough and sharp edges. Note: The identified sharp edges resulting from the disassembly of the packing cone extensions have been repaired and cleared, no further action is required. Examiner: Mike Schantz Level: II Date: 12/24/09 Examiner: Gordon Austin Level: II Date: 12/24/09

41 LIQUID PENETRANT EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: S1 Component: Windage Covers WO: Code: N/A Material: Aluminum Preparation: As found Temperature: 72 F Visible: Yes Fluorescent: N/A Black Light Int: N/A Solvent Removable: Yes Cleaner Type: SKC-S Batch No: 06K02K Water Washable: N/A Penetrant Type: SKL-SP1 Batch No: 05L01K FQS Procedure: 003 Developer Type: SKD-S2 Batch No: 04G11K Component Acc. Rej. Remarks/Indications A Windage Covers (1-4) X No indications noted B Windage Covers (1-4) X No indications noted C Windage Covers (1-4) X No indications noted Summary of Inspection Performed: Visible red dye liquid penetrant inspection was performed on the A, B, & C Windage Covers. All covers were found acceptable, with no indications noted. A & B Windage Covers C Windage Covers Examiner: Mike Schantz Level: II Date: 12/22/2010 Examiner: Josh Porter Level: II Date: 12/22/2010

42 ULTRASONIC EXAMINATION REPORT PAGE 1 Customer: Sample Turbine Outage PO No: Report No: N/A Component: Bolting & Studs WO No: Drawing: N/A Material: C/S Prep: Blasted Test: 65 Procedure: 005 Code: N/A Instrument: Manufacturer: Model: Serial Number: Material Velocity: Panametrics Epoch III N/A Range: Gain: Reject: Scan Sensitivity: Sweep Delay: Varied 54 db N/A + 2 db N/A Transducer: Manufacturer: Frequency: Wave Mode: Size & Shape: Angle: KBA 2.25 Long. 1/2 Round Normal Couplant: Type: Ultragel Batch Number: Calibration: Cal Block No.: Part Thickness: CRT Cal Inches: Major Scrn. Div.: N/A Varied Varied Varied Cal. Times: Initial: 07:30 Final: 18:00 Scanning: 100% Weld: 100% Base Mat.: Parallel to Weld: Trans. To Weld: N/A N/A N/A N/A Summary of Inspection Performed: A UT inspection was performed on selected bolting and studs from the turbine assembly, a complete list of studs/bolts inspected, as well as the results of the inspection can be seen below. General view of bolting & stud inspection area

43 ULTRASONIC EXAMINATION REPORT PAGE 2 Item/Weld No. A R Remarks/Indications A Coupling Studs (12) X No loss of backwall reflection B Coupling Studs (12) X No loss of backwall reflection Crossover Vertical Joint Studs (39) X No loss of backwall reflection HP Turbine End Crossover Vertical Joint Studs (48) X No loss of backwall reflection Inner Shell Outside Bolts (Left Side) LP (A) Left Side (8) X No loss of backwall reflection LP (B) Left Side (8) X No loss of backwall reflection Inner Shell Outside Bolts (Right Side) LP (A) Right Side (8) X No loss of backwall reflection LP (B) Right Side (8) X No loss of backwall reflection Upper Steam Chest Studs (41) X No loss of backwall reflection Lower Steam Chest Studs (24) X No loss of backwall reflection #1 Stop Valve Bonnet Studs (15) X No loss of backwall reflection #2 Stop Valve Bonnet Studs (15) X No loss of backwall reflection #3 Stop Valve Bonnet Studs (14*) X No loss of backwall reflection 1 stud broken during disassembly No UT performed #4 Stop Valve Bonnet Studs (15) X No loss of backwall reflection #1 Upper Control Valve Studs (10) X No loss of backwall reflection #2 Upper Control Valve Studs (9*) X No loss of backwall reflection 1 stud broken during disassembly No UT performed #3 Upper Control Valve Studs (10) X No loss of backwall reflection #4 Upper Control Valve Studs (9*) 1 stud broken during disassembly No UT performed Sketch/Comments: General view of bolting & stud inspection area Examiner: Brian Spada Level: II Date: 12/28/2010 Examiner: Level: Date:

44 LIQUID PENETRANT EXAMINATION REPORT Customer: Sample Turbine Outage PO: Report No: N/A Component: Fan Blades WO: Code: N/A Material: Aluminum Preparation: Brushed Temperature: 68 F Visible: Yes Fluorescent: N/A Black Light Int: N/A Solvent Removable: Yes Cleaner Type: SKC-S Batch No: 06K02K Water Washable: N/A Penetrant Type: SKL-SP1 Batch No: 05L01K FQS Procedure: 003 Developer Type: SKD-S2 Batch No: 04G11K Component Acc. Rej. Remarks/Indications Turbine End Generator Fan Blades (24) X No indications noted Collector End Generator Fan Blades (24) X No indications noted Summary of Inspection Performed: Visible red dye liquid penetrant inspection was performed on the turbine end and collector end generation fan blades (48 total). All fan blades were found acceptable, with no indications noted. Generator Fan Blades Examiner: Mike Schantz Level: II Date: 12/21/2010 Examiner: Josh Porter Level: II Date: 12/21/2010

Unit s 1 & New Berlin Road No.109 Jacksonville, Florida Global Power Generation Services, All Rights Reserved.

Unit s 1 & New Berlin Road No.109 Jacksonville, Florida Global Power Generation Services, All Rights Reserved. Unit s 1 & 2 Turbine Generator Inspections Summary Unit s 1 & 2 are of the same design; Single Flow Condensing Steam Turbine with Hydrogen Cooled Generators, both sets are installed on an outdoor pedestal

More information

CHAPTER 64 TAIL ROTOR. Section Title Page

CHAPTER 64 TAIL ROTOR. Section Title Page CHAPTER 64 TAIL ROTOR Section Title Page 64-00 Description........................................ 64.1 64-10 Tail Rotor Assembly.................................. 64.1 64-11 Static Balance..............................

More information

Steampath Services Capabilities. The Turbine-Generator Engineering & Outage Services Company

Steampath Services Capabilities. The Turbine-Generator Engineering & Outage Services Company Steampath Services Capabilities The Turbine-Generator Engineering & Outage Services Company Steampath Engineering Services Mechanical Dynamics & Analysis is one of the world s leading suppliers of steampath

More information

GUIDE FOR CERTIFICATION AND INSPECTION OF WHEEL SHOPS. Routine Special Shop Certification Follow up Inspection

GUIDE FOR CERTIFICATION AND INSPECTION OF WHEEL SHOPS. Routine Special Shop Certification Follow up Inspection GUIDE FOR CERTIFICATION AND INSPECTION OF WHEEL SHOPS Routine Special Shop Certification Follow up Inspection M-1003 Approved ISO Approved SR = See Report Attachments Y/N N/A NI = Not Inspected # MOUNTED

More information

Advanced Outage Compression Methods for Steam Turbines. Nicholas Marsh 13 th February 2012

Advanced Outage Compression Methods for Steam Turbines. Nicholas Marsh 13 th February 2012 Advanced Outage Compression Methods for Steam Turbines Nicholas Marsh 13 th February 2012 Agenda Introduction Page 3 Water Jet Cleaning Page 5 Water Jet Cutting Page 10 Automated Phased Array Ultrasonic

More information

S02. MAGNETIC PARTICLE TESTING

S02. MAGNETIC PARTICLE TESTING S02.1 Scope This procedure is for the examination of ferromagnetic surface and near surface indications in stressed areas of welds, drilling or production equipment, or as a prove up technique. Both wet

More information

ULTRASONIC EXAMINATION

ULTRASONIC EXAMINATION Page 1 of 9 ULTRASONIC EXAMINATION PROCEDURE Doc. No. KNS/UT/01.REV 0 Page: 9 of 9 Date: 15.09.2012 ULTRASONIC EXAMINATION PROCEDURE PREPARED & APPROVED BY NDE- Level III CERTIFIED BY REVIEWED BY Page

More information

TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES

TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES 17715 St Rose Road St Rose, Illinois 62230 www.testdrivetech.com Phone: 636-388-8378 Email: info@testdrivetech.com TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES Vehicle Identification Inspection

More information

ARTICLE 5 ULTRASONIC EXAMINATION METHODS FOR MATERIALS

ARTICLE 5 ULTRASONIC EXAMINATION METHODS FOR MATERIALS ARTICLE 5 ULTRASONIC EAMINATION METHODS FOR MATERIALS 04 T-510 SCOPE This Article provides or references requirements, which are to be used in selecting and developing ultrasonic examination procedures

More information

Prevention vs. Reaction The Importance of Asset Integrity

Prevention vs. Reaction The Importance of Asset Integrity Prevention vs. Reaction The Importance of Asset Integrity How Your Assets Typically Age Inspections Potential Failure Condition Functional Failure Time P-F Interval Why is Asset Integrity so Important?

More information

Dynamic Balancing. Need a high-speed balance? No problem.

Dynamic Balancing. Need a high-speed balance? No problem. Dynamic Balancing TOSHIBA is one of North America s leading turbine/generator service providers. Our unique highspeed balance and overspeed facility assures that proper balance is achieved prior to returning

More information

Pre-Purchase Inspection Report

Pre-Purchase Inspection Report Inspecting Shop Name Address Phone Shop Foreman Mechanic Year Make Model Vin Color Miles Engine ECM Horsepower Torque Transmission Engine Brake 3 stage Rear Ends Model Ratio Differential Lock Steering

More information

Howard Midstream Energy Partners LLC Contractor Covered Task List Last updated 10/11/2013

Howard Midstream Energy Partners LLC Contractor Covered Task List Last updated 10/11/2013 001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005

More information

Turbine & Generator Rotor Welding to Solve Reliability and Performance Issues. Tom Smith President T and A Consultants April 16-17, 2013

Turbine & Generator Rotor Welding to Solve Reliability and Performance Issues. Tom Smith President T and A Consultants April 16-17, 2013 Turbine & Generator Rotor Welding to Solve Reliability and Performance Issues Tom Smith President T and A Consultants April 16-17, 2013 Rotor Welding History Rotor welding was developed in the U.S. in

More information

Date of Addendum Issue: Effective Addendum Date: Affected Publication: ADDENDUM 2

Date of Addendum Issue: Effective Addendum Date: Affected Publication:  ADDENDUM 2 Date of Addendum Issue: August 2011 Effective Addendum Date: February 1, 2012 Affected Publication: API Specification 6D, Specification for Pipeline Valves, 23rd Edition, April 2009, Effective Date: October

More information

Report of Inspection

Report of Inspection P. O. Box 8238 Searcy, AR 72145 866.811.5237 / 501.279.1166 Fax: 501.279.1225 As required by NFPA 1911 19.3: CFS Inspections is accredited to the requirements of ISO/IEC 17020. Report of Inspection SAFET

More information

Figures T Basic Calibration Block T Straight Beam Calibration Blocks for Bolting

Figures T Basic Calibration Block T Straight Beam Calibration Blocks for Bolting A02 ARTICLE 5 T-510 Scope... 102 T-520 General... 102 T-521 Basic Requirements... 102 T-522 Written Procedure Requirements... 102 T-530 Equipment... 102 T-531 Instrument... 102 T-532 Search Units... 102

More information

TO WRITE ON THIS LABEL USE AN INDELIBLE, PERMANENT INK MARKER, PEN OR PENCIL THAT WILL NOT FADE INDIRECT SUNLIGHT

TO WRITE ON THIS LABEL USE AN INDELIBLE, PERMANENT INK MARKER, PEN OR PENCIL THAT WILL NOT FADE INDIRECT SUNLIGHT TO WRITE ON THIS LABEL USE AN INDELIBLE, PERMANENT INK MARKER, PEN OR PENCIL THAT WILL NOT FADE INDIRECT SUNLIGHT ANNUAL VEHICLE INSPECTION LABEL No. 37425582 COMPLETED: MONTH 0 7D YEAR lol 42 A RECORD

More information

Liquid Turbine Flowmeter

Liquid Turbine Flowmeter NUFLO Liquid Turbine Flowmeter User Manual 167018 Explosion-proof for use in Class I, Division I, Groups A, B, C, D Hazardous Environments ANSI 12.27.01-2003 Single Seal Part No. 9A-100062201, Rev. 01

More information

These instructions are applicable to the following models: ARI 1108 ARI HP1108

These instructions are applicable to the following models: ARI 1108 ARI HP1108 INSPECTION & MAINTENANCE BULLETIN ARI 1108 & HP1108 Safety Relief Valve These instructions are applicable to the following models: ARI 1108 ARI HP1108 Only AAR class F facilities are certified to recondition,

More information

Simplifying Inspection MAGNETIC PARTICLE TESTING ACCESSORIES

Simplifying Inspection MAGNETIC PARTICLE TESTING ACCESSORIES MPI Accessories 7 Magnaflux 7 Magnetic Particle Testing Accessories are designed to help improve the speed, detection capabilites, and cost effectiveness of your MPI system. Simplifying Inspection 48 CABLES,

More information

Enbridge Gas Transmission and Midstream and Enbridge Liquid Pipelines (Express-Platte) Contractor Covered Task List Last updated 8/30/2018

Enbridge Gas Transmission and Midstream and Enbridge Liquid Pipelines (Express-Platte) Contractor Covered Task List Last updated 8/30/2018 001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral

More information

ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP

ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP 1988 Chrysler LeBaron Convert/Coupe 1988 ALTERNATORS & REGULATORS Chrysler Motors - Bosch 35/75 & 40/90 Amp Alternator All Models DESCRIPTION The charging system

More information

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS PAGE : 1 / 13 4. PRESSURISER 4.1. DESCRIPTION The pressuriser (PZR) is a pressurised vessel forming part of the reactor coolant pressure boundary (CPP) [RCPB]. It comprises a vertical cylindrical shell,

More information

EnLink Midstream Contractor Covered Task List Last updated 11/8/2017

EnLink Midstream Contractor Covered Task List Last updated 11/8/2017 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428

More information

LM2500 BORESCOPE INSPECTION REPORT

LM2500 BORESCOPE INSPECTION REPORT LM2500 BORESCOPE INSPECTION REPORT UC DAVIS CUSTOMER UNIT NAME/NUMBER: N/A ENGINE SERIAL NUMBER: 481-743 TCT SALES ORDER NUMBER: US9010290 DATE INSPECTED:11-29-2018 SERVICEABILITY AT DATE OF INSPECTION:

More information

Rolls -Royce M250--C47M OPERATION AND MAINTENANCE

Rolls -Royce M250--C47M OPERATION AND MAINTENANCE TABLE 603 Inspection Checksheet Owner Date A/C Make/Model S/N Reg. No. TSN Engine S/N TSN TSO This inspection checksheet is to be used when performing scheduled inspections. This form can be locally reproduced

More information

Simplifying Inspection MAGNETIC PARTICLE TESTING ACCESSORIES

Simplifying Inspection MAGNETIC PARTICLE TESTING ACCESSORIES MAGNETIC PARTICLE TESTING ACCESSORIES MPI Accessories 7 Magnaflux 7 Magnetic Particle Testing Accessories are designed to help improve the speed, detection capabilites, and cost effectiveness of your MPI

More information

Rolls -Royce M250--C47B OPERATION AND MAINTENANCE TABLE 603. Inspection Checksheet. A/C Make/Model S/N Reg. No. TSN

Rolls -Royce M250--C47B OPERATION AND MAINTENANCE TABLE 603. Inspection Checksheet. A/C Make/Model S/N Reg. No. TSN TABLE 603 Inspection Checksheet Owner Date A/C Make/Model S/N Reg. No. TSN Engine S/N TSN TSO This inspection checksheet is to be used when performing scheduled inspections. This form can be locally reproduced

More information

These instructions are applicable to the following models: ARI 1118 ARI 1148

These instructions are applicable to the following models: ARI 1118 ARI 1148 INSPECTION & MAINTENANCE BULLETIN ARI 1118 & 1148 Safety Relief Valve These instructions are applicable to the following models: ARI 1118 ARI 1148 Only AAR class F facilities are certified to recondition,

More information

Noble Energy Contractor Covered Task List Last updated 2/20/2019

Noble Energy Contractor Covered Task List Last updated 2/20/2019 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428

More information

Rolls -Royce M250--C47M OPERATION AND MAINTENANCE

Rolls -Royce M250--C47M OPERATION AND MAINTENANCE TABLE 603 Inspection Checksheet Owner Date A/C Make/Model S/N Reg No. TSN Engine S/N TSN TSO This inspection checksheet is to be used when performing scheduled inspections. This form may be locally reproduced

More information

ESTABLISHMENT OF ULTRASONIC TESTING IN UNIQUE DESIGNED PARTIAL PENETRATION END PLUG OF HEADER IN BOILERS.

ESTABLISHMENT OF ULTRASONIC TESTING IN UNIQUE DESIGNED PARTIAL PENETRATION END PLUG OF HEADER IN BOILERS. Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation NDE 2011, December 8-10, 2011 ESTABLISHMENT OF ULTRASONIC TESTING IN UNIQUE DESIGNED PARTIAL PENETRATION END PLUG OF HEADER

More information

Mass Tank Inspection Services, LLC 29 Abbey Lane Middleboro, MA masstankinspection.com

Mass Tank Inspection Services, LLC 29 Abbey Lane Middleboro, MA masstankinspection.com June 18, 2018 Mrs. Nancy Cole Administrator Village of Eidelweiss 1680 Conway RD Madison, NH 03849 Mass Tank Inspection Services, LLC 29 Abbey Lane Middleboro, MA 02346 508-947-8826 masstankinspection.com

More information

Zip's Truck Equipment. 316 W. Milwaukee Street New Hampton, Iowa Phone: Fax: Visual Inspection.

Zip's Truck Equipment. 316 W. Milwaukee Street New Hampton, Iowa Phone: Fax: Visual Inspection. Zip's Truck Equipment 316 W. Milwaukee Street New Hampton, Iowa 50659 Phone: 641-394-3166 Fax: 641-394-4044 Visual Inspection Page: 1 of 6 Customer: Address: Division: Phone: null Reference #: 2NPRLZ9X37M730087

More information

TAB B. Hydrotest Summary Report. Piping Specifications and Procedures. Pipe Manufacturers. Order XG-N Application for Leave to Open

TAB B. Hydrotest Summary Report. Piping Specifications and Procedures. Pipe Manufacturers. Order XG-N Application for Leave to Open NOVA Gas Transmission Ltd. Alces River B2 Compressor Station Order XG-N081-026-2015 Application for Leave to Open TAB B Hydrotest Summary Report Piping Specifications and Procedures Pipe Manufacturers

More information

Southern Star Central Gas Pipeline Contractor Covered Task List Last updated 8/15/2018

Southern Star Central Gas Pipeline Contractor Covered Task List Last updated 8/15/2018 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 018 Inspect Navigable Waterway Crossing 195.412(b) 201 Abnormal Operating Conditions Related to Welding on Pipelines 192.225

More information

TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES

TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES 17715 St Rose Road St Rose, Illinois 62230 www.testdrivetech.com Phone: 636-388-8378 Email: info@testdrivetech.com TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES Vehicle Identification Inspection

More information

INSPECTION TECHNIQUE FOR BWR CORE SPRAY THERMAL SLEEVE WELD

INSPECTION TECHNIQUE FOR BWR CORE SPRAY THERMAL SLEEVE WELD More Info at Open Access Database www.ndt.net/?id=18479 INSPECTION TECHNIQUE FOR BWR CORE SPRAY THERMAL SLEEVE WELD ABSTRACT J.L. Fisher, G. Light, Jim Crane, Albert Parvin, Southwest Research Institute,

More information

Generator. Jason S DiSanto. 6B Users Conference San Antonio, TX June 19-22, 2017

Generator. Jason S DiSanto. 6B Users Conference San Antonio, TX June 19-22, 2017 Generator Jason S DiSanto 6B Users Conference San Antonio, TX June 19-22, 2017 GE Power 2017, General Electric Company. GE Proprietary Information - The information contained in this document is General

More information

Rolls -Royce M250--C40B OPERATION AND MAINTENANCE. Table 603. Inspection Checksheet

Rolls -Royce M250--C40B OPERATION AND MAINTENANCE. Table 603. Inspection Checksheet Table 603 Inspection Checksheet Owner Date A/C Make/Model S/N Reg. No. TSN Engine S/N TSN TSO This inspection checksheet is to be used when performing scheduled inspections. This form can be locally reproduced

More information

Operating & Maintenance Manual For Steam Conditioning Valve

Operating & Maintenance Manual For Steam Conditioning Valve For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0

More information

PIPELINE PIGS types of mechanical pigs. Pig length (inches) = 1 and ½ pipeline diameters.

PIPELINE PIGS types of mechanical pigs. Pig length (inches) = 1 and ½ pipeline diameters. PIPELINE PIGS A cleaning pig is any free traveling cleaning device that is sent through a pipeline by product flow to scrape and brush foreign deposits, rust and dirt and fluids from the inside surface

More information

Chromalloy. Borescope and Test Report. Prepared for. Triumph Air Repair A Triumph Group Company

Chromalloy. Borescope and Test Report. Prepared for. Triumph Air Repair A Triumph Group Company A Triumph Group Company Borescope and Test Report Prepared for Chromalloy Customer P.O.#: S2669 A.P.U. Model #: GTCP331-200ER A.P.U. Serial #: P-2796 A.P.U. Part #: 3800298-1 Triumph SRO #: S000013678

More information

Hands On Test Scoring Instructions

Hands On Test Scoring Instructions Hands On Test Scoring Instructions Each scoring box contains 3 to 6 line items and up to 7 numbers plus a 0. Each section has a separate criteria for scoring. Based on the criteria, you will score the

More information

SRT OPERATIONS MANUAL

SRT OPERATIONS MANUAL MAINTENANCE SECTION PAGE # VEHICLE DAILY INSPECTION.......................................1 P.M. INSPECTION #1.................................................3 P.M. INSPECTION #2.................................................6

More information

MOTOR GRADERS. Inspector: MWK Inspection #

MOTOR GRADERS. Inspector: MWK Inspection # MOTOR GRADERS Date Created: 12-7-18 Location: SMITHVILLE Inspector: MWK Inspection # Manufacturer: CAT Model: 140H Serial #: CCA01924 Year: 06 Engine SN:? Transmission SN:? SMU/Hrs: 4783 Last Scheduled

More information

Retriever 5800G/P/D. revised 2/01 Form Number

Retriever 5800G/P/D. revised 2/01 Form Number Retriever 5800G/P/D PARTS LIST Advance MODELS 56482005, 56482010, 56482015 This parts list is for machines after serial number 221134 All models covered in this manual are OBSOLETE revised 2/01 Form Number

More information

MX-5 Concours Scoresheet

MX-5 Concours Scoresheet MX- Concours Scoresheet SECTIONS 2 onwards ARE TO BE COMPLETED BY EVENT JUDGES RATING SCALE Outstanding Very Good Good Fair Poor 4 3 2 1 9 8 7 6 4 3 2 1 Owner s Name: Rego: Current KM s: Year Model: SECTION

More information

Table of Contents. 4. Before a New Turbocharger is Installed

Table of Contents. 4. Before a New Turbocharger is Installed Table of Contents 1. Turbocharger Overview ------------------------------------------------------------------ 1.1. Definition -----------------------------------------------------------------------------

More information

Unit Number: RDC001 SMU: Date: Feb 2, 2014

Unit Number: RDC001 SMU: Date: Feb 2, 2014 MAINTCLF002 CAT 777BCD DUMP TRUCK 500HR SERVICE Unit Number: C001 SMU: 10256 Date: Feb 2, 2014 SAMPLE Initial Engine Transmission Hydraulic / Brakes Steering Front hubs LH (X) RH (X) Differential Final

More information

TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES

TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES 17715 St Rose Road St Rose, Illinois 62230 www.testdrivetech.com Phone: 636-388-8378 Email: info@testdrivetech.com TEST DRIVE TECHNOLOGIES VEHICLE INSPECTION SERVICES Vehicle Identification Inspection

More information

STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE

STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE Michael W. Smiarowski, Rainer Leo, Christof Scholten, Siemens Power Generation (PG), Germany John Blake,

More information

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents. 1 10/2014 REV 7 !!Attention!! Before performing diagnostics: Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents. Check for Fault Codes using the

More information

M-11 MARINE DIESEL ENGINE FUEL INJECTOR

M-11 MARINE DIESEL ENGINE FUEL INJECTOR Guideline No.M-11(201510) M-11 MARINE DIESEL ENGINE FUEL INJECTOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

Inspection and Repair of Compressor Wheels

Inspection and Repair of Compressor Wheels Subject: Applicable EXTEX Engineered Products Part Numbers: Installations: Revision History: Reason: Description: Inspection and Repair of Compressor Wheels E23057111 (Stage 1), E23057112 (Stage 2-3),

More information

SECTION AIR INTAKE SYSTEM

SECTION AIR INTAKE SYSTEM 09-500.295/ 1 2007AL05 SECTION 09-500.295 AIR INTAKE Air for the engine is taken in through a grille located on the upper-rear, left-hand side of the vehicle. See Figure 1. Air passes through a chamber,

More information

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES GENERAL NOTES " - - -" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. 3rd

More information

Dominion Energy Questar Pipeline LLC Contractor Covered Task List Last updated 10/3/2017

Dominion Energy Questar Pipeline LLC Contractor Covered Task List Last updated 10/3/2017 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 104 Non-destructive Testing (Other than testing of

More information

Zip's Truck Equipment. 316 W. Milwaukee Street New Hampton, Iowa Phone: Fax: Visual Inspection.

Zip's Truck Equipment. 316 W. Milwaukee Street New Hampton, Iowa Phone: Fax: Visual Inspection. Zip's Truck Equipment 316 W. Milwaukee Street New Hampton, Iowa 50659 Phone: 641-394-3166 Fax: 641-394-4044 Visual Inspection Page: 1 of 6 Customer: Division: null Address: Phone: Reference #: 1GBKC34J9VJ103606

More information

Pressure Vessel Assessment Report

Pressure Vessel Assessment Report Project Information Client: Total Energy Location: Blackwell OK Date: 7/23/2013 Contact: Integrity Mgmt. Advisor: Chuck Easterbrooks - API 510 #2212 Cc: API / UT Inspector: Robert Van Pelt-API 510# 40899

More information

TOYOTA PRIUS 2004 TVIP V2 (GBS ADD ON) Section I Installation Preparation

TOYOTA PRIUS 2004 TVIP V2 (GBS ADD ON) Section I Installation Preparation Section I Installation Preparation Part Number: 08586 47840 Section I Installation Preparation Kit Contents Item # Quantity Reqd. Description 1 1 Wire Harness 2 1 3 1 ECU Mounting Bracket Hardware Bag

More information

Steam Turbine 34.5-Inch Low-Pressure Section Upgrade

Steam Turbine 34.5-Inch Low-Pressure Section Upgrade GE Energy Steam Turbine 34.5-Inch Low-Pressure Section Upgrade Kim Kavney Joe Lesiuk Jim Wright GE Energy Atlanta, GA Contents Introduction...1 Fleet Demographics...1 Reasons for Low-Pressure Section

More information

MINI PACK BUILD SPEC. 885 ESN: FA0278 TSN: 15, CSN: 15,815 TSO: N/A CSO: N/A TSHSI: 2, CSHSI: 2,373 RGB SN. FA0278

MINI PACK BUILD SPEC. 885 ESN: FA0278 TSN: 15, CSN: 15,815 TSO: N/A CSO: N/A TSHSI: 2, CSHSI: 2,373 RGB SN. FA0278 MINI PACK ENGINE Model: BUILD SPEC. 885 ESN: PW150A FA0278 TSN: 15,012.30 CSN: 15,815 TSO: N/A CSO: N/A TSHSI: 2,056.00 CSHSI: 2,373 RGB SN. FA0278 TSN: 15,012.30 CSN: 15,815 TSO: 3,596.40 CSO: 3,863 CONTENTS:

More information

2014 Volvo L250G Serial #: VCEL250GC

2014 Volvo L250G Serial #: VCEL250GC 2014 Volvo L250G Serial #: VCEL250GC00003258 Cowin Equipment Montgomery, AL 800-239-6642 SMU/Hours: 9918 Start Run: Yes Overall: Fair Insp Date: 11/15/2017 http://www.leaseinspector.com/creditor/viewkwl.asp?settab=cr&print=yes&assetid=115525

More information

DEVELOPMENT OF NEW MANIPULATORS FOR PWR AND VVER VESSEL INSPECTION. Authors: Mats Wendel and Torbjörn Sjö, DEKRA Industrial, Sweden

DEVELOPMENT OF NEW MANIPULATORS FOR PWR AND VVER VESSEL INSPECTION. Authors: Mats Wendel and Torbjörn Sjö, DEKRA Industrial, Sweden DEVELOPMENT OF NEW MANIPULATORS FOR PWR AND VVER VESSEL INSPECTION Authors: Mats Wendel and Torbjörn Sjö, DEKRA Industrial, Sweden ABSTRACT TIME, has been the key word for the inspection of Ringhals PWR

More information

PARTS CATALOGUE / TECHNICAL GUIDE

PARTS CATALOGUE / TECHNICAL GUIDE PARTS CATALOGUE / TECHNICAL GUIDE [SPECIFICATIONS] Item Movement Cal. No. Cal. 5T82A 5T82A (x 1.0) Movement size Time indication Driving system Outside diameter Casing diameter Height (Movement intervals)

More information

RAPID RESPONSE TRANSMITTAL SERVICE ACTION # REV. B 3.5L #2 Rod Bearing and Crankshaft Journal Inspection for Contamination.

RAPID RESPONSE TRANSMITTAL SERVICE ACTION # REV. B 3.5L #2 Rod Bearing and Crankshaft Journal Inspection for Contamination. August 10, 2006 TO: FROM: SUBJECT: ALL CHRYSLER AND DODGE DEALERS GLOBAL SERVICE RAPID RESPONSE TRANSMITTAL SERVICE ACTION #06-025 REV. B 3.5L #2 Rod Bearing and Crankshaft Journal Inspection for Contamination.

More information

TransCanada US Contractor Covered Task List Last updated 9/27/2018

TransCanada US Contractor Covered Task List Last updated 9/27/2018 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428

More information

Saddle Butte Rockies Midstream LLC Contractor Covered Task List Last updated 12/6/2017

Saddle Butte Rockies Midstream LLC Contractor Covered Task List Last updated 12/6/2017 003 Test Breakout Tank Overfill Protective N/A 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective N/A 195.428 Oral 005 Repair Breakout Tank Overfill Protective N/A 195.428 007 Operate

More information

Transducers, Cables, Couplants and Test Blocks for Ultrasonic Precision Thickness Gages

Transducers, Cables, Couplants and Test Blocks for Ultrasonic Precision Thickness Gages s, Cables, Couplants and Test Blocks for Ultrasonic Precision Thickness Gages Olympus NDT offers a complete selection of transducers, cables, couplants, calibration test blocks, and accessories to meet

More information

SERVICE LETTER. Multi-engine MEL TITLE NACELLES/PYLONS - ENGINE BEAM INSPECTION

SERVICE LETTER. Multi-engine MEL TITLE NACELLES/PYLONS - ENGINE BEAM INSPECTION TITLE NACELLES/PYLONS - ENGINE BEAM INSPECTION EFFECTIVITY MODEL SERIAL NUMBERS 402C 402C0001 thru 402C1020 414A 414A0001 thru 414A1212 REASON Cracks have been discovered on some engine beams. The cracks

More information

Standard DS-1 Fourth Edition, Volume 4 - ADDENDUM 1 Applies to First Printing only

Standard DS-1 Fourth Edition, Volume 4 - ADDENDUM 1 Applies to First Printing only Page 72 7.5.2.4 7.5.2.4 MPI Body Inspection Coverage. When the outside surface of the tool from shoulder to shoulder. Pay special attention to areas around load adjustment ports and external oil plug holes

More information

TAM International, Inc. QI Visible Magnetic Particle Inspection

TAM International, Inc. QI Visible Magnetic Particle Inspection TAM International, Inc. QI-8.2.4-12 Visible Magnetic Particle Inspection Approved by Quality Assurance Manager Signature/Date: Greg Fletcher Reviewed by Sr. Quality Analyst Signature/Date: Thomas Young

More information

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516 COMPANY Pneumatic Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516 Technical Specifications Measuring Accuracy ±2.5% of full scale

More information

GIOUP 11 EXHAUST SYSTEM

GIOUP 11 EXHAUST SYSTEM EXHAUST SYSTEM 11-1 GIOUP 11 EXHAUST SYSTEM CONTENTS Page Exhaust Manifold...... -4 Exhaust Pipes, Mufflers and Tail Pipes... 5 -Intake Manifold... 4 Manifold Heat Control Valve... 5 Manifold Heat Control

More information

WS-Series. Operating Instructions. Pulse DC End Area Coils. Drilco Style WS-Series Coils 1. E s t a b l i s h e d WS-14 WS-12 WS-10 WS-8

WS-Series. Operating Instructions. Pulse DC End Area Coils. Drilco Style WS-Series Coils 1. E s t a b l i s h e d WS-14 WS-12 WS-10 WS-8 E s t a b l i s h e d 1 9 6 5 26509 Township Road 543 Phone: (780) 459-6720 Sturgeon County, Alberta Fax: (780) 459-7837 T8T 1M1 Canada E-Mail: info@westerninstruments.com Web: www.westerninstruments.com

More information

PRODUCTS. Multi-Stage Steam Turbines. Proven reliability and efficiency

PRODUCTS. Multi-Stage Steam Turbines. Proven reliability and efficiency PRODUCTS Multi-Stage Steam Turbines Proven reliability and efficiency Introduction Proven Reliability and Efficiency Dependable, versatile turbomachinery is essential for today s refinery, chemical process,

More information

OPERATION & MAINTENANCE SPECIFICATIONS MANUAL 09 09

OPERATION & MAINTENANCE SPECIFICATIONS MANUAL 09 09 S SCOPE This section is intended for the guidance of NDE personnel qualified in accordance with the requirements of M&NP Training and Qualification of Personnel. The inspection processes and procedures

More information

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation. Industrial Turbo Meters Sizes 2" through 6" Installation & Operation Manual IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation. BadgerMeter,Inc. IOM-003-15 Part No.

More information

Nurse Tank Inspection Report Instructions (DOT-SP Special Permit)

Nurse Tank Inspection Report Instructions (DOT-SP Special Permit) Nurse Tank Inspection Report Instructions (DOT-SP 13554 Special Permit) Following numbers correspond to each box on the Nurse Tank Inspection Report form. 1. PREVIOUS NTIP NUMBER Insert the previous NTIP

More information

If you have any questions or concerns, please contact: Jeremy Gulley (845) or

If you have any questions or concerns, please contact: Jeremy Gulley (845) or If you have any questions or concerns, please contact: Jeremy Gulley (845) 887-4117 or blauser_4@yahoo.com Full size (STOCK V8 and RWD 6 cylinder) Compact (4 cylinder RWD or FWD and 6 cylinders FWD) General:

More information

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.anderson-negele.com Instrument Model Number Instrument Serial Number 2A 2AU

More information

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

Instruction Manual. RZ Positive Displacement Flowmeters 2AU Instruction Manual AndersonInstrumentCo.Inc.. 156AuriesvilleRoad Fultonville,NY12072 1-800-833-0081 Fax518-922-8997 Www.andinst.com InstrumentModelNumber InstrumentSerialNumber 2A 2AU 3A RZ Positive Displacement

More information

2-row and All-row systems included.

2-row and All-row systems included. Ag Leader Technology Cotton Picker Installation Installation Instructions for John Deere cotton picker models: 2-row and All-row systems included. IMPORTANT: Ensure the model numbers shown above correspond

More information

FRONT SUSPENSION GROUP 33A 33A-1 CONTENTS GENERAL DESCRIPTION... 33A-2 FRONT SUSPENSION DIAGNOSIS. 33A-3 LOWER ARM... 33A-13 SPECIAL TOOLS...

FRONT SUSPENSION GROUP 33A 33A-1 CONTENTS GENERAL DESCRIPTION... 33A-2 FRONT SUSPENSION DIAGNOSIS. 33A-3 LOWER ARM... 33A-13 SPECIAL TOOLS... 33A-1 GROUP 33A FRONT SUSPENSION CONTENTS GENERAL DESCRIPTION......... 33A-2 DIAGNOSIS. 33A-3 INTRODUCTION TO DIAGNOSIS........................ 33A-3 DIAGNOSIS TROUBLESHOOTING STRATEGY...... 33A-3 SYMPTOM

More information

GROUP 33A 33A-1 CONTENTS GENERAL DESCRIPTION... 33A-2 FRONT SUSPENSION DIAGNOSIS. 33A-3 LOWER ARM... 33A-13 SPECIAL TOOLS... 33A-5

GROUP 33A 33A-1 CONTENTS GENERAL DESCRIPTION... 33A-2 FRONT SUSPENSION DIAGNOSIS. 33A-3 LOWER ARM... 33A-13 SPECIAL TOOLS... 33A-5 33A-1 GROUP 33A CONTENTS GENERAL DESCRIPTION 33A-2 DIAGNOSIS 33A-3 INTRODUCTION TO FRONT SUSPENSION DIAGNOSIS 33A-3 DIAGNOSIS TROUBLESHOOTING STRATEGY 33A-3 SYMPTOM CHART 33A-3 SYMPTOM PROCEDURES 33A-3

More information

AGA Touch Up & Repair Videos. 35% inconsistency/ difference in appearance main factor

AGA Touch Up & Repair Videos. 35% inconsistency/ difference in appearance main factor Poor quality touch-up & repair leads to eventual maintenance by the user Specifier Survey: 12% users, 30% non-users quoted aesthetics as primary reason to avoid HDG 35% inconsistency/ difference in appearance

More information

INTAKE/EXHAUST SYSTEM 7 C TURBOCHARGER

INTAKE/EXHAUST SYSTEM 7 C TURBOCHARGER INTAKE/EXHAUST SYSTEM 7 C TURBOCHARGER Table Of Contents Page Identification.................................. 7C-1 Torque Specifications.......................... 7C-1 Sealants.....................................

More information

FR11A Fender, Welded-On

FR11A Fender, Welded-On Uniform Procedures For Collision Repair FR11A Fender, Welded-On 1. Description This procedure describes the repair and complete replacement of a welded-on aluminum fender. Inspection and evaluation requirements

More information

SERVICE BULLETIN. Fuselage Tail Cone Damage

SERVICE BULLETIN. Fuselage Tail Cone Damage Fuselage Tail Cone Damage It has come to our attention that a number of Sportsman tailwheel installations have resulted in crushed and/or delaminated fuselage laminates near the aft tailwheel bracket.

More information

FRONT SUSPENSION GROUP CONTENTS GENERAL INFORMATION FASTENER TIGHTENING SPECIFICATIONS GENERAL SPECIFICATIONS...

FRONT SUSPENSION GROUP CONTENTS GENERAL INFORMATION FASTENER TIGHTENING SPECIFICATIONS GENERAL SPECIFICATIONS... 33-1 GROUP 33 FRONT SUSPENSION CONTENTS GENERAL INFORMATION 33-2 FASTENER TIGHTENING SPECIFICATIONS 33-2 GENERAL SPECIFICATIONS 33-3 SERVICE SPECIFICATIONS 33-3 DIAGNOSIS 33-4 INTRODUCTION TO DIAGNOSIS

More information

Principles of NDT Methods on Railway Axles

Principles of NDT Methods on Railway Axles Sheet 1 of 38 Dipl.-Ing. Thomas Heckel, BAM VIII.43 Dipl.Ing. Uwe Völz, BAM VIII.43 Dipl.-phys. Rainer Boehm, BAM VIII.42 11.10.2010 Sheet 2 of 38 1. Introduction 2. NDT by manufacturer 3. In-service inspection

More information

V/VT-378, V/VT-504, and V/VT-555 Engines

V/VT-378, V/VT-504, and V/VT-555 Engines V/VT-378, V/VT-504, and V/VT-555 Engines Service Manual Service Manual THIS IS A MANUAL PRODUCED BY JENSALES INC. WITHOUT THE AUTHORIZATION OF CUMMINS OR IT S SUCCESSORS. CUMMINS AND IT S SUCCESSORS ARE

More information

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System Technical Bulletin C PORTABLE LIQUID PUMP AND FILTER SYSTEMS DESCRIPTION Filtration Systems Portable Liquid Pump &

More information

Commissioning Manual PLATE HEAT EXCHANGER. Customer Name: Serial number: Purchase order number: Project:

Commissioning Manual PLATE HEAT EXCHANGER. Customer Name: Serial number: Purchase order number: Project: Commissioning Manual PLATE HEAT EXCHANGER Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name

More information

Pressure Transmitter. Informational & Installation Manual

Pressure Transmitter. Informational & Installation Manual Pressure Transmitter Informational & Installation Manual February 24, 2011 M374 Rev. E JOWA USA, Inc. 59 Porter Road Littleton, MA 01460 Phone: 978-486-9800 Fax: 978-486-0170 Care and Handling Our submersible

More information

Gas turbine outage Sept 2012 Bad things happen to a well planned outage

Gas turbine outage Sept 2012 Bad things happen to a well planned outage Gas turbine outage Sept 2012 Bad things happen to a well planned outage 1- Signed contract 2- All new parts ordered and received 3- All parts identified and on site 4- Scope of work complete for: Rotor

More information

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS COMMERCIAL GRADE METERS Look for the silver label! Look for the silver label! COMMERCIAL GRADE METERS Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters

More information