1 003 Test Breakout Tank Overfill Protective Devices Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices Repair Breakout Tank Overfill Protective Devices Inspection of Breakout Tanks Oral and Certificate 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 009 Movement and/or Relocation of Liquid Pipelines Inspect, Test and Maintain Computational Pipeline Monitoring (CPM) Sensing Devices 012 Inspect, Test and Maintain Liquid Leak Detection Flow Computers 013 Inspect, maintain and Test Tank Gauges for CPM Hazardous Liquid Leak Detection 014 Maintain/Prove Flow Meters for CPM Hazardous Liquid Leak Detection 015 Inspect, Test and Maintain Gravitometers/Densitometers for CPM Hazardous Liquid Leak Detection 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 104 Non-destructive Testing (Other than testing of welds) - Dye Penetrant Inspection (DPI) (h) (h)(4)(iii )(G) 110 Pipeline Expansion External Measurement 201 Abnormal Operating Conditions Related to Welding on Pipelines Monitoring of Welding Process (a) (c) Visual Inspection of Welds not Non-Destructively Tested (b) (c) Yes 1:1 2 Oral Oral Page 1 Copyright Veriforce, LLC. All rights reserved. Rev. 1
2 204 Non-Destructive Testing (Dye Penetrant) Non-Destructive Testing (Mag Particle) Non-Destructive Testing (Ultrasonic) Non-Destructive Testing (X-Ray) Plastic Pipe Joining: Butt Fusion Plastic Pipe Joining: Mechanical Joining Plastic Pipe Joining: Electrofusion Joining Perform Plastic Fusion Inspection 213 Joining of Metal Pipe and Components by means other than Welding - Threaded and Flanged Connections 214 Joining of Metal Pipe and Components by means other than Welding - Threaded Connections 215 Joining of Metal Pipe and Components by means other than Welding- Flanged Connections Joining of Metal Pipe - Compression Couplings Small Diameter Metal Tubing and Fitting Installation Plastic Pipe Joining: Solvent Cement (d) (b) (c) 219 Plastic Pipe Joining: Stab Fittings Install Tracer (electrically conductive) Wire (e) NA Page 2 Copyright Veriforce, LLC. All rights reserved. Rev. 1
3 330 Installation of Plastic Pipe in a Ditch (a) 331 Installation of Plastic Pipe in a Bore of Buried Pipelines When Exposed Protection of Coating When Backfilling and From Below Ground Supports (d) (c)(6) ( c ) (b) Protection of Coatings From Above Ground Structures (d) 406 Conduct Test to Determine Cathodic Protection Current Requirements (a) (d)(6) 407 Perform Cathodic Protection Survey (a) (e) (e) (d)(6) (a) 408 Inspect Cathodic Protection Rectifier (b) ( c ) 409 Inspect Interference Bonds (c) ( c ) 410 Clear Shorted Casing (c) (b)(1) (a) 411 Inspect/Test to Assure Electrical Isolation is Adequate (d) (d)(6) Install CP Leads on Pipeline Using Exothermic Weld Anode Installation on Submerged Pipeline or Facilities Inspect for Internal Corrosion Whenever Pipe is Removed (b)(1) 415 Monitoring for Internal Corrosion with Probes and Coupons (d)(5) 416 Monitoring for Internal Corrosion with Gas Samples (c) (b) 417 Atmospheric Corrosion Monitoring General and Localized Corrosion Measurement (Remedial Measures) (a)(b) 419 Cathodic Protection Potential Measurement (a) (d)(8) (b) (a) Page 3 Copyright Veriforce, LLC. All rights reserved. Rev. 1
4 420 Soil Resistivity 421 Measurement of Depth of Pitting with Pit Gage Assessment of Pipeline Segments Using Long Range Guided Wave UT 423 Perform Direct Current Voltage Gradient (DCVG) Survey (d)(7) 424 Perform AC Current Attenuation (ACCA) Survey (e) (d)(7) 425 Perform Alternating Current Voltage Gradient (ACVG) Survey (h)(3) (d)(7) 426 Inspect Pipe Coating with Holiday Detector (a) (a) Inspection of Coating Application (a) (c) (a) Oral 428 Pin Brazing to Install CP Leads on Pipeline Monitoring for corrosion - bacteria testing - serial dilution method (MIC) 430 Installation and Testing of Mechanical Electrical Connections (a) Install Cathodic Protection Electrical Isolation Devices Troubleshoot In-Service Cathodic Protection System Visual Inspection of Installed Pipe and Components for Mechanical Damage 435 Measure and Identify Mechanical Damage on Installed Pipe and Components Perform Close Survey (e) (e) (d)(6) & (7) (a) 437 Perform Hot Spot Survey (e) (a) 480 Apply Approved Coating by Hand Application (a) Apply Approved Coatings by Mechanical Spray and Hand Application Methods (a) Page 4 Copyright Veriforce, LLC. All rights reserved. Rev. 1
5 484 Apply Approved Coatings by Wrap Application (a) Conduct a Pressure Test (d) 502 Conduct Pressure Test on Pipe that is to be Operated at a Pressure <100 psig (b) 611 Hot Tap (Steel Pipe) Hot Tap (Plastic Pipe) Atmospheric Monitoring during Hot Work Operations ( c )(11) 617 Locate Buried Facilities with an Electro-magnetic Device (c)(5) (c)(5) 618 Install Temporary Marking of Buried Pipeline (c)(5) (c)(5) 619 Damage Prevention during Vacuum Excavation and Backfilling Activities 621 Provide or Assure Adequate Pipeline Support during Operator Initiated Excavation Activities (c)(6) (c)(6) Oral 702 Leakage Survey with Leak Detection Device Placing/Maintaining Line Markers (a) (c) 704 Permanent Field Repair by Grinding Permanent Field Repair Using Composite Materials (Clockspring) 706 Permanent Field Repair Using Composite Materials (Armor Plate) 707 Permanent Field Repair Using Bolt-On Clamp/Sleeve (a) 708 Permanent Field Repair Using Full Encirclement Weld Sleeve 709 Inspection and Testing of Relief Devices (Compressor Stations, Meter Stations, Regulating Stations) (a) (a) (b) Inspect, Test, and Maintain Systems (c) (b)(1) (b)(1) Oral Yes 1:0 1 Page 5 Copyright Veriforce, LLC. All rights reserved. Rev. 1
6 712 Programmable Logic lers (c) (b)(1) (a) 713 Test/Maintain Gas Detection and Alarm Systems (c) 714 Inspect and Maintain Pressure ing and Regulating Devices 715 Test and Maintain Pressure Switches and Transmitters in Pressure ing and Regulating Service (a) (b) (a) (b) 716 Inspect, Maintain, and Operate Valves Monitoring for Internal Corrosion with Liquid Samples Permanent Field Repair Using Composite Materials (Wrapmaster) 721 Permanent Field Repair Using Composite Materials (Black Diamond) 722 Permanent Field Repair Using Composite Materials (Aqua Wrap) (a) Leakage Survey with Remote Laser Leak Detection Device (a) 724 Permanent Field Repair Using Composite Materials (PipeWrap A+ / Atlas CFP) ( a ) 725 Aerial Leakage Survey: Transmission Aerial Leakage Survey: Transmission (UV/IR) Valve (Pneumatic) Actuator/Operator Inspection, Testing and Maintenance 737 Valve (Hydraulic) Actuator/Operator Inspection, Testing and Maintenance 738 Valve (Electric) Actuator/Operator Inspection, Testing and Maintenance 741 Installation and Maintenance of Casing Spacers, Vents and Seals Inspection and Repair of Rupture Pin Devices (b) (b) Yes 1:0 1 Yes 1:0 3 Yes 1:0 3 Yes 1: Hauling, Stringing and Handling Pipe Oral 902 Field Bending of Pipe Page 6 Copyright Veriforce, LLC. All rights reserved. Rev. 1
7 903 Directional Drilling and/or Boring (c)(6) Oral 904 Inspection of Material (a)(1) Oral 905 Lowering/Installation of Steel Pipe into Ditch (a) Rights-of-Way Cleanup (d)(4) 908 Installation of Cathodic Protection (c)(6) 910 Inspection of Construction Activities (c)(6) 911 Depth of Cover Verification (d)(4)(iii ) 921 Operate/Test/Maintain Sulfur (H2S) Analyzers (d)(5)(iii ) Oral Oral NA NA Page 7 Copyright Veriforce, LLC. All rights reserved. Rev. 1
EnLink Midstream Contractor Covered Task List Last updated 11/8/2017
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationHoward Midstream Energy Partners LLC Contractor Covered Task List Last updated 10/11/2013
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005
More informationEnergy Transfer Partners LP Contractor Covered Task List Last updated 12/10/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005
More informationEnergy Transfer Partners LP Contractor Covered Task List Last updated 3/2/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationWilliams Contractor Covered Task List Last updated 11/7/2017
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationDominion Energy Questar Pipeline LLC Contractor Covered Task List Last updated 10/3/2017
007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 104 Non-destructive Testing (Other than testing of
More informationNorthern Natural Gas Contractor Covered Task List Last updated 4/26/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationEnbridge Gas Transmission and Midstream and Enbridge Liquid Pipelines (Express-Platte) Contractor Covered Task List Last updated 8/30/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationTransCanada US Contractor Covered Task List Last updated 9/27/2018
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationSouthern Star Central Gas Pipeline Contractor Covered Task List Last updated 8/15/2018
007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 018 Inspect Navigable Waterway Crossing 195.412(b) 201 Abnormal Operating Conditions Related to Welding on Pipelines 192.225
More informationDCP Midstream Contractor Covered Task List Last updated 7/11/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 009 Movement and/or Relocation of Liquid Pipelines 195.424 011 Inspect,
More informationEpic Consolidated Operations LLC Contractor Covered Task List Last updated 9/6/2018
003 Test Breakout Tank Overfill Protective 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective 195.428 Oral 005 Repair Breakout Tank Overfill Protective 195.428 006 Inspection of Breakout
More informationSaddle Butte Rockies Midstream LLC Contractor Covered Task List Last updated 12/6/2017
003 Test Breakout Tank Overfill Protective N/A 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective N/A 195.428 Oral 005 Repair Breakout Tank Overfill Protective N/A 195.428 007 Operate
More informationBoardwalk Pipeline Partners, LP Contractor Covered Task List Last updated 9/17/2018
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationColumbia Pipeline Group Contractor Covered Task List Last updated 1/8/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationBlack Hills Energy Contractor Covered Task List Last updated 10/10/2018
007 Operate Valves 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 201 Abnormal Operating Conditions Related to Welding on Pipelines 195.452(h) 192.225 192.227 192.715 192.717
More informationAppendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 8/24/2018
Abnormal Operating Conditions Outside of 101.01 Room Abnormal Operating Conditions Inside of 101.02 Room 102.01 Measure Structure-to-Soil Potentials 102.02 Advanced Cathodic Testing 102.03 Active Corrosion/MIC
More informationAppendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 12/12/2017
Abnormal Operating Conditions Outside of 101.01 Room Abnormal Operating Conditions Inside of 101.02 Room 102.01 Measure Structure-to-Soil Potentials 102.02 Advanced Cathodic Testing 102.03 Active Corrosion/MIC
More informationAppendix A Kinder Morgan Operator Qualification Program List of Covered Tasks - Natural Gas - Part 192 Revised 12/13/2017
01.01.01 Abnormal Operating Conditions (AOC) - Outside of Room 01.01.02 Abnormal Operating Conditions (AOC) - Inside of Room (new task effective 1/1/2018) 02.01.01 Gas Detection & Alarm System Maintenance
More informationASMECourseCatalog.
ASMECourseCatalog www.energyu.org www.midwestenergy.org ASME Abnormal Operating Conditions... 6 ASME GAS01 Hazards of Natural Gas and Prevention of Accidental Ignition... 6 ASME 0001 Measure Structure-to-Electrolyte
More informationOperator Qualification (OQ) Report
AOCF 66102/67107 Abnormal Operating Conditions Field for Natural Gas and Hazardous Liquids 5/15/2014 5/15/2017 AOCG 67107 Abnormal Operating Conditions for Natural Gas 5/16/2014 5/16/2017 TM001 66101 02
More informationFlorida City Gas Contractor Covered Task List
001A Abandonment and deactivation of facilities 192.727 001B 001C 001SUBA Abandonment and deactivation of facilities (service lines not in use) Abandonment and deactivation of facilities (service lines
More informationCOVERED TASK Conduct Cathodic Protection Surveys 1 DESCRIPTION ELEMENTS OF TASK 4 PART QUESTION NOTES ABNORMAL OPERATING CONDITIONS
COVERED Conduct Cathodic Protection Surveys 1 Annual surveys are conducted for each operator s pipeline system that is under cathodic protection to ensure that the protection is adequate. This task is
More informationPIPELINE CORROSION CONTROL
NCCER 13614 Progress Blvd, Alachua, Florida 32615 Phone: (888) 622-3720 E-mail: info@nccer.org PIPELINE CORROSION CONTROL Competencies / Objectives Level One MODULE 66101-02 INTRODUCTION TO THE PIPELINE
More informationNew UST Installation Inspection Checklist
Nebraska State Fire Marshal Fuels Division - FLST Section 246 South 14 TH Street - Lincoln, NE 68508-1804 (402) 471-9466 New UST Installation Inspection Checklist (Petroleum or Hazardous Substances) Inspection
More informationPIGGING PRODUCTS. Capex supply. PIG LAUNCHER and RECEIVER
PIGGING PRODUCTS Capex supply PIG LAUNCHER and RECEIVER Before Cleaning After Cleaning TYPES OF PIGS DISPLACEMENT AND BATCHING PIGS AND PIG WITH BLADES (FOR CLEANING) 2 to 6 3 and 4 PIG with blades 5 to
More informationInspector's Initials: Tank Owner or Agent Signature: Title: Date:
STATE OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF UNDERGROUND STORAGE TANKS 4 TH Floor, L & C Tower 401 Church Street Nashville, TN 37243-1541 UST OPERATIONS INSPECTION Mo /Day
More informationPHMSA Office of Pipeline Safety Dave Mulligan Western Region
PHMSA Office of Pipeline Safety Dave Mulligan Western Region Chevron Pipeline Releases Salt Lake City, Utah June 11, 2010 & December 1, 2011 Dave Mulligan U.S. Department of Transportation (US DOT) Pipeline
More informationANNUAL UST SYSTEM INSPECTION CHECKLIST
APPENDIX A-3: SAMPLE FORM FOR ANNUAL UNDERGROUND STORAGE SYSTEM INSPECTION CHECKLIST Page 1 ANNUAL UST SYSTEM INSPECTION CHECKLIST Facility ID# Facility Name/Address Qualified Technician Signature Date
More informationOfficial Journal of the European Union L 298/39
16.11.2011 Official Journal of the European Union L 298/39 B3 6.8 Bearings 1 2 2 1 Purpose of bearings, loads, material, construction; Types of bearings and their application. 6.9 Transmissions 1 2 2 1
More informationMonthly Checklist For Depot
Monthly Checklist For Depot ANNEXURE 1.L(iv) TANK FARM Notes : i. The scope covers piping, valve & fittings, general housekeeping, pumps & motors, effluent management, fire protection and security within
More informationPROCEDURE EXTRUDED HOT TAP & LINE STOP TEES DESIGN & MANUFACTURING VALIDATION
6534 Petropark Dr. Houston, TX 77041 USA Tel: +1 713-937-6193 Fax: +1 713-937-8695 www.uni-forge.com PROCEDURE EXTRUDED HOT TAP & LINE STOP TEES DESIGN & MANUFACTURING VALIDATION Prepared by: Approved
More informationBolting QA/QC Bulletin
Bolting QA/QC Bulletin M&TE Review 8-27-14 There have been several incidents over the past few months regarding torqueing methods, calibration procedures and verification of conversion charts matching
More informationSteel Tank Maintenance. Fluid Fertilizer Foundation December 4, 2012
Steel Tank Maintenance Fluid Fertilizer Foundation December 4, 2012 Tank Failure History Storage tank failure is as old as storage tank usage On January 15, 1919 a U.S. Industrial Alcohol Company s tank
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationSPCC Regulation Integrity and Leak Testing Methods
SPCC Regulation Integrity and Leak Testing Methods NISTM New England December 3 rd, 2015 Founded in 1988, Tanknology has grown to become one of the largest testing and inspection service companies in the
More informationCONTENTS. Foreword...iii. 1. Introduction...1
Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1
More informationPipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair
CLOCK SPRING Pipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair 3 x 18 repairs were made in support locations. The Pipe could not be raised so blocks were inserted and the supports
More informationRolls -Royce M250--C47M OPERATION AND MAINTENANCE
TABLE 603 Inspection Checksheet Owner Date A/C Make/Model S/N Reg No. TSN Engine S/N TSN TSO This inspection checksheet is to be used when performing scheduled inspections. This form may be locally reproduced
More informationThe Implementation of a Storage Facility Inspection Program. Presented By: John R. Rueckel PCA Engineering, Inc.
The Implementation of a Storage Facility Inspection Program Presented By: John R. Rueckel PCA Engineering, Inc. Storage Facility Inspection Why implement an inspection program? Regulatory Requirements
More informationBroetje-Automation Company Standard Structural component specification for welded parts
Broetje-Automation Company Standard Table of Contents Application Area and Purpose 3 1 Structural components pursuant to DIN 1090 4 1.1 Structural component classification 4 1.1.1 Steel components < Strength
More information7. UST Piping Corrosion Protection. NCDENR Division of Waste Management Underground Storage Tank Section
7. UST Piping Corrosion Protection NCDENR Division of Waste Management Underground Storage Tank Section 1 Where piping connects to tank Piping Corrosion Protection 2 Main run of piping 3 Where piping connects
More informationThis article discusses a tank
CASE HISTORY Hot Oil Aboveground Storage Tank Bottom Corrosion Failure and Cathodic Protection Upgrade Part 2 KEVIN C. GARRITY AND PHILIP D. SIMON, CC Technologies, Inc. Several types of anode installations
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP MODEL SSO-9MED DRAWING NUMBERS AD243DI AD243DK AD243DK.K1 MANUAL NUMBER IOM-175 REVISION Rev. B, 3/21/2017 TABLE OF CONTENTS
More informationNo Infrared Refrigerant Leak Detector
No. 22791 Infrared Refrigerant Leak Detector Operator s Manual Product Description The Robinair No. 22791 uses infrared optics to create a refrigerant leak detector that combines sensitivity, speed, battery
More informationNortheast Ohio AWWA October 26, 2017
Northeast Ohio AWWA October 26, 2017 Introduction Karl Dickinson Regional Sales Manager Jack Doheny Companies Sell & Rent Vacuum Trucks, Sewer Cleaning Equipment, & Pipeline Inspection Systems 16 Service
More informationFINAL REPORT CATHODIC PROTECTION EVALUATION. 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to South Texas Water Authority
FINAL REPORT CATHODIC PROTECTION EVALUATION 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to 50+00 South Texas Water Authority Prepared for: South Texas Water Authority P.O. Box 1701 Kingsville,
More informationTRADE EXPERIENCE LOG BOOK CANADIAN PETROLEUM CONTRACTORS ASSOCIATION. Petroleum Mechanic Training & Certification
CANADIAN PETROLEUM CONTRACTORS ASSOCIATION Petroleum Mechanic Training & Certification TRADE EXPERIENCE LOG BOOK PM1 - Service & Maintenance PM2 - Underground Installation PM3 - Aboveground Installation
More informationMonitoring Cathodic Protection of Natural Gas Pipelines
Monitoring Cathodic Protection of Natural Gas Pipelines Period #8 Basic Corrosion Course 2017 February 21-23, 2017 Steve Glover - Vectren 0 Chapter Objective: Introduction Reasons to monitor What to monitor
More informationThe Gradient Control Mat (GCM)
The (GCM) Installation Instructions INTRODUCTION Most gradient control mats are designed and installed around above ground pipeline appurtenances to limit power frequency voltages. The Dairyland gradient
More informationGeneral Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.
Part Lists Great Plains Manufacturing, Inc. 1 Installation Instructions Loup Shaft Monitor Used with Drill models: Compatible with most 1995 and later, two- and three-box drills with 5 8 -inch square main
More informationCHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES
CHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES FOR ALL FOUR OZONE NONATTAINMENT AREAS:! Delay of repair beyond the next process unit shutdown is allowed if the component is isolated from
More informationHDPE FUSIBLE VALVES EXPECT INNOVATION
AVK HDPE FUSIBLE VALVES HDPE FUSIBLE VALVES EXPECT INNOVATION AVK HDPE VALVES SERIES 89 FUSIBLE BUTTERFLY VALVE Series 89 fusible butterfly valves are designed for quick, direct heat butt-fusion or electrofusion
More informationUnderground Storage Tank Annual Compliance Inspection (Revised 1/2015)
Colorado Department of Labor and Employment Division of Oil and Public Safety Compliance Section 633 17 th Street, Suite 500 Denver, CO 80202-3610 Phone: 303-318-8525 Fax: 303-318-8518 Email: cdle_oil_inspection@state.co.us
More informationAsset Protection Cathodic Protection Testing of Insulating Joints. Work Instruction No.:
Asset Protection Cathodic Protection Testing of Insulating Joints Approved by: Manager Pipeline Standards 1 PURPOSE This work instruction describes the requirements and process for testing the integrity
More informationAssembly instructions
Assembly instructions CP-Lube kit RX4,RX8,RX22,RX25,RX29,RX45,RX53 CP-Lube kit RX 4 CP-Lube kit RX 8 CP-Lube kit RX 22 CP-Lube kit RX 25 CP-Lube kit RX 29 CP-Lube kit RX 45 CP-Lube kit RX 53 Valid from
More informationCASE STUDY ON PIPELINE UNDER-PROTECTION ALONG WITH MITIGATION METHODS. Vipul Vilas Sawant. Mahanagar Gas Ltd, Mumbai, India
Paper No. CAP34 CASE STUDY ON PIPELINE UNDER-PROTECTION ALONG WITH MITIGATION METHODS Vipul Vilas Sawant Mahanagar Gas Ltd, Mumbai, India vsawant@mahanagargas. com ABSTRACT Mahanagar Gas Ltd is a City
More informationMethodologies and practices for non-piggable lines Andreas Landsteiner Integrity Department - Transalpine Pipeline (TAL)
Methodologies and practices for non-piggable lines Andreas Landsteiner Integrity Department - Transalpine Pipeline (TAL) COPEX 2010 Brussels 1 Presentation overview (1) What are non-piggable lines? (2)
More informationA. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.
SECTION 221513 - COMPRESSED-AIR PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. 1.2
More informationAn Introduction to Constructing and Maintaining Cathodic Protection Systems
An Introduction to Constructing and Maintaining Cathodic Protection Systems Course No: T02-009 Credit: 2 PDH J. Paul Guyer, P.E., R.A., Fellow ASCE, Fellow AEI Continuing Education and Development, Inc.
More informationHighway Crossings - Cased or Uncased
Highway Crossings - Cased or Uncased Maryland Quality Initiative Annual Conference Baltimore Convention Center Baltimore, Maryland Steve Nanney PHMSA Office of Pipeline Safety January 31, 2013-1 - PHMSA
More informationPEI/RP Recommended Practices for Installation of Bulk Storage Plants
PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1
More informationBid Summary Still Creek Wastewater Improvements Phase III City Job No. 411-D November 21, 2013
Bid Summary Still Creek Wastewater Improvements Phase III City Job No. 411-D4-1102 November 21, 2013 Doughtie Construction Co., Elliott Construction Dudley Construction Ltd. SUBTOTAL GENERAL ITEMS : $191,713.00
More informationFisher 657 Diaphragm Actuator Sizes and 87
Instruction Manual 657 Actuator (30-70 and 87) Fisher 657 Diaphragm Actuator Sizes 30 70 and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Mounting
More informationGF Piping Systems. SurTap System Operation with VersaTap Fittings Manual
GF Piping Systems SurTap System Operation with VersaTap Fittings Manual Thank you for selecting Georg Fischer Central Plastics products. GFCP strives to deliver the best technology and materials combined
More informationGUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007
GUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007 AMERICAN GLOVEBOX SOCIETY STANDARDS DEVELOPMENT COMMITTEE All Rights Reserved Copyright 2007 No portion may be duplicated without written consent
More informationCOMPANY PROFILE 0045
0045 COMPANY PROFILE INTRODUCTION TO THE COMPANY THE MICROFINISH WAY Microfinish Valves Pvt. Ltd. is a privately owned and managed company specializing in industrial valves for energy, process, and natural
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE MODELS AIP-1 AIP-2 DRAWING NUMBERS AD198CA AD198CM AD198CO AD198DK.1 AD455BG AD455BO AD455EO MANUAL NUMBER IOM-006 REVISION
More informationApplication for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information
Papillion/La Vista Fire Marshal s Office Fuels Division FLST Section 146 rth Adams Street Papillion, NE 68046 (402) 829-1398 Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous
More informationSECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS
SECTION 23 11 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Fuel Pipe and Pipe Fittings - General 2. Steel Pipe and Fittings, Above Grade 3. Steel Pipe and Fittings, Below Grade 4. Polyethylene
More informationBaumann Sanitary Diaphragm Angle and Inline Control Valve
Instruction Manual 84000 Valve Baumann 84000 Sanitary Diaphragm Angle and Inline Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Flow Direction...
More informationCathodic Protection for AST s. Why is Cathodic Protection Important?
Cathodic Protection for AST s Presented by: James T. Lary Corrpro Companies, inc. 1055 West Smith Road Medina, Ohio 44256 jlary@corrpro.com 330-241-6615 Why is Cathodic Protection Important? Preserve Assets
More informationLINE STOPPING. Extending and modifying your existing pressurized system while it s under full operating conditions.
Extending and modifying your existing pressurized system while it s under full operating conditions. Line Stops are used to temporarily shut down a pipeline system to complete modifications or repairs.
More informationThin-line. Weld Heads
Thin-line Weld Heads AMADA MIYACHI's Thin-Line Heads for spot welding applications comprise three families of fullfeatured products for resistance spot welding: 80 Series (0.25 lbs (N) - 40 lbs (78N)),
More informationGAS DISTRIBUTION PRODUCTS METER RISERS
GAS DISTRIBUTION PRODUCTS METER RISERS INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today a leading manufacturer
More informationReport of Inspection
P. O. Box 8238 Searcy, AR 72145 866.811.5237 / 501.279.1166 Fax: 501.279.1225 As required by NFPA 1911 19.3: CFS Inspections is accredited to the requirements of ISO/IEC 17020. Report of Inspection SAFET
More informationTHE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS
THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com
More informationThis publication is copyrighted and intended for the sole use of General Industries - 07/07/2016
AQUASWEEP JUNE 2009 INSTALLATION INSTRUCTIONS FOR AQUASWEEP UNDERGROUND OIL WATER SEPARATORS PREFACE i. Install the AquaSweep Oil Water Separator using personnel who have knowledge and experience in procedures
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11065-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 08.02.2016 to 07.02.2021 Holder of certificate: Actemium
More informationOperating & Maintenance Manual For Steam Conditioning Valve
For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0
More informationPIPELINE PIGS types of mechanical pigs. Pig length (inches) = 1 and ½ pipeline diameters.
PIPELINE PIGS A cleaning pig is any free traveling cleaning device that is sent through a pipeline by product flow to scrape and brush foreign deposits, rust and dirt and fluids from the inside surface
More informationAnnex of the Certificate (Page 1/4) Scope of Accreditation
Annex of the Certificate (Page 1/4) As a "Type A" Inspection Body Address : Keresteciler Sitesi E Blok No:5 Kat:2 Ostim / Yenimahalle 06170 ANKARA/TÜRKİYE Phone : +90 312 385 95 30 Fax : +90 312 386 00
More informationFISC Puget Sound Manchester Fuel Department. Maintenance, Leak Detection in Large Underground Storage Tanks. Glenn E. Schmitt, P.E.
FISC Puget Sound Manchester Fuel Department Glenn E. Schmitt, P.E. Environmental Director Fleet and Industrial Supply Center Puget Sound Maintenance, Leak Detection in Large Underground Storage Tanks Ready.
More informationVal-Matic Extended Bonnet Assembly Instructions
Manual No. EBAI-OM-2 Val-Matic Extended Bonnet Assembly Instructions Operation, Maintenance and Installation Manual DESCRIPTION OF ASSEMBLY... 1 INSTALLATION INSTRUCTIONS... 1 TROUBLESHOOTING... 1 PARTS
More informationFirst Quality Solutions
First Quality Solutions Turbine Inspection Reports www.firstqualitysolutions.org VISUAL EXAMINATION REPORT Customer: Sample Turbine Outage PO: 104568912 Report No: S1 Component: Turbine Components WO:
More informationLACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31
LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the
More informationINSTALLATION INSTRUCTIONS
R913 FRP COMPOSITE STEEL UNDERGROUND STORAGE TANKS INSTALLATION INSTRUCTIONS February 2017 1.0 EXCAVATION AND BEDDING 1.1 The bottom of the excavation shall be covered with a minimum of 12 inches (305
More informationESTABLISHMENT OF ULTRASONIC TESTING IN UNIQUE DESIGNED PARTIAL PENETRATION END PLUG OF HEADER IN BOILERS.
Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation NDE 2011, December 8-10, 2011 ESTABLISHMENT OF ULTRASONIC TESTING IN UNIQUE DESIGNED PARTIAL PENETRATION END PLUG OF HEADER
More informationOPERATING AND MAINTENANCE MANUAL
Series 2200 Series 2220 Engineered Performance TABLE OF CONTENTS INTRODUCTION 1 About the Series 2200/ 2220 Valve 1 Identifying the valves 1 1.0 VALVE INSTALLATION AND START-UP 2 2 0 VALVE MAINTENANCE
More informationClient Success Story Sheri Baucom Senior Advisor II
Client Success Story - 2017 Sheri Baucom Senior Advisor II Overview The following is a description of an actual project completed in 2016 where RCP was deployed onsite to validate a pressure test using
More informationFluid Fertilizer Foundation December 10, 2013
Storage Tank Inspection, Maintenance, and Failure Fluid Fertilizer Foundation December 10, 2013 1 Tank Failure History Storage Tank Failure is as old as storage tank usage http://en.wikipedia.org/wiki/boston_molasses_disaster
More informationCable-Tight Wire Management System
Cable-Tight Wire Management System Installation Guide Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com Safety
More informationINSERTA VALVE SLEEVE INSERTA VALVE ASSEMBLY. Valve insertion, simplified MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS.
MADE IN U.S.A. Valve insertion, simplified 10-12 installations in cast iron, ductile iron, A/C, PVC C-900 and steel pipe No Loss of Pressure Minimal Water Loss Completion time is less than 2 hours Much
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17579-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 07.07.2017 to 06.07.2022 Holder of certificate: gammatest
More informationInline Ultrasonic Flowmeter
M-1500 Series Installation and Operating Manual The M-1500 series is an inline primary flow sensor and externally mounted controller unit. The flow sensor is a straight through flow tube that uses Transit
More informationRosemount 402 and 402VP
Rosemount 402 and 402VP Contacting Conductivity Sensors Instruction Manual LIQ-MAN-402 Rev. M May 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and
More informationReport No.: Name of Ship: Plans referred during Initial Survey:
Report on the Surveys Concerning International Oil Pollution Prevention Certificate Part 7 Survey of installation for discharges from cargo spaces Initial/ Annual/ Intermediate/ Renewal/ Change of Flag
More informationWater Connection Repair Method and Techniques
Water Connection Repair Method and Techniques LINE LOCATES APWA Colour Codes Representatives from utility companies can field locate their lines if required. Excavation Ensure excavation is on the opposite
More informationAnnex of the Certificate (Page 1/5) Scope of Accreditation
Annex of the Certificate (Page 1/5) As a "Type A" Inspection Body Address : Esas Maltepe Ofispark Altayçeşme Mah. Çamlı Sokak No:21 Kat:8 Maltepe 34843 İSTANBUL/TÜRKİYE Phone : +90 216 518 40 50 Fax :
More informationBaumann Series Flexsleev Control Valve Instructions
Instruction Baumann 86000 Series Instructions Baumann 86000 Series Flexsleev Control Valve Instructions Contents Introduction...1 Scope...1 Safety Precautions...1 Maintenance...2 Installation...3 Air Piping...3
More information