22PD/32PD Series. High Pressure Duplex Filters. A duplex design with a wide application capability. Product Features: Contact Information:
|
|
- Hilary Roberts
- 5 years ago
- Views:
Transcription
1 / Series High Pressure Duplex Filters A duplex design with a wide application capability Designed to offer continuous operation during element change The / Series utilizes a duplex design with integrated balancing valve and vent ports. Microglass lll glassfibre media is standard. Maximum pressure upstream side of the filter, ensuring a contamination free system. Contact Information: European Product Information Centre Freephone: (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: balancing valve and vent ports. change FDHB5UK.
2 / Series High Pressure Duplex Filters Features & Benefits Features Duplex design Vent ports Visual, electrical and electronic indicators available Advantages Element service possible during operation Purges all trapped air in filter Multi-layered design produced high capacity and efficiency Wire support reduces pleat bunching, keeps performance consistent Check element condition at a glance Right style for the application Benefits full contamination protection Safety and reliability Get the maximum performance from the elements Prevents a "flabby" system Great performance value Reliable performance throughout element life Reduces downtime, maximises element life Optimises element life, prevents bypassing Matches your system electrical connections Typical Applications Ship steering systems Continuous operation industrial systems High flow flushing systems The Parker Filtration / Series High Pressure Duplex Filters. Specially designed to offer continuous operation, even during element change. of the filter, ensuring a contamination free system. FDHB5UK.
3 Specification Pressure ratings: Maximum allowable operating pressure 21 bar. Filter housing pressure pulse fatigue tested: 1 cycles 21 bar. Connections: Connection style Model BSPF(G) /4 1 /4 1 1 /2 Filter housing: Bowl material steel. Seal material: or Fluoroelastomer. Operating temperature range: Seal material : -4 C to +1 C. Seal material Fluoroelastomer: -2 C to +12 C. Bypass valve: Opening pressure Filter element: Degree of filtration: Flow fatigue characteristics: Filter media is supported so that the optimal fatigue life is achieved Microglass III: Supported with epoxy coated metal wire mesh, end cap material reinforced composite and metal inner core. Collapse rating 2 bar High collapse elements: (to be used when no bypass function in filter housing). upstream and stainless steel on downstream, end cap material steel. Indicator options: - visual M3. - electrical T1. - electronic F1(PNP). - electronic F2(NPN). Weights (kg): Model Length Fluid compatibility: Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration. Dimensions mm (inches) Model A B C D E F G H I J K L M N PD (9.45) (1) 35 (1.38) (5.12) 18 (.71) 2 (.79) (3.7) 15 (5.91) (2.21) 33 (2.28) (3.7) 12 (4.72) (9.45) 75 (2.95) 3 (1.18) (1.42) 59 (2.32) 7 (2.75) 3.75Ø 38Ø 345 (13.58) 317 (12.48) 437 (17.2) D Out B mm (inches) J G E N 4 mounting holes : M8x1.2 pitchx12 deep : M1x pitchx15 deep H 2 bleed holes G 1 /8 F Changeover handle Balance valve Bleed valve Hexagon C Bowl removal 1mm (3.93) Flange face detail L M12x1.72 pitch x2 deep M K 177 FDHB5UK.
4 / Series High Pressure Duplex Filters Pressure Drop Curves The recommended level of initial pressure drop is max. 1.2 bar. p = ( p3 x viscosity of medium used) / 3 cst. The total p = housing ph + (element pe x working viscosity/3). / Bypass Valve / Empty Housing Cracking Pressure Elements Elements Q 5Q 1Q 2Q Q 2Q 5Q 1Q Elements -2 Elements Q 5Q 1Q 2Q Q 5Q 1Q 2Q FDHB5UK.
5 -1 High Collapse Elements High Collapse Elements QH 5QH 1QH 2QH QH 5QH 1QH 2QH High Collapse Elements -2 High Collapse Elements QH 5QH 2QH 1QH QH 5QH 1QH 2QH Ordering Information Standard products table Part number 21QBM3KG161 21QBT1KG161 22QBM3KG161 22QBT1KG161 21QBM3KG21 21QBT1KG21 22QBM3KG21 22QBT1KG21 Supersedes -22-PD-2-1Q-V-5-C-1-22-PD-2-1Q-TW3-5-C-1-22-PD-2-2Q-V-5-C-1-22-PD-2-2Q-TW3-5-C-1-32-PD-2-1Q-V-5-D-1-32-PD-2-1Q-TW3-5-D-1-32-PD-2-2Q-V-5-D-1-32-PD-2-2Q-TW3-5-D-1 Flow (l/min) Model number Element length Media rating (µ) Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above Seals Indicator Visual Electrical Visual Electrical Visual Electrical Visual Electrical Bypass settings Ports G1" G1" G1" G1" G1 1 /4" G1 1 /4" G1 1 /4" G1 1 /4" Replacement elements G1315Q G1315Q G1938Q G1938Q G198Q G198Q G1954Q G1954Q Part Number S4233 S4234 S4234 S4234 / Series Seal Kits Description 179 FDHB5UK.
6 / Series High Pressure Duplex Filters Ordering Information (cont.) Product configurator Box 1 Box 2 2 Box 3 1Q Box 4 B Box 5 M3 K Box 7 G16 Box 8 1 Box 1 Model Small high pressure duplex filter Large high pressure duplex filter Box 2 Length Length 1 Filter type 1 2 Box 3 Element media High collapse element Degree of filtration Glass fibre Media code 2Q 2QH 5Q 5QH 1Q 1QH 2Q 2QH Box 4 Seal type Seal material Fluoroelastomer B V Box 5 Visual indicator Electrical indicator Plugged with steel plug No indicator port Electronic 4 LED, PNP, N.O. Electronic 4 LED, NPN, N.O. Electronic 4 LED, PNP, N.C. Electronic 4 LED, NPN, N.C. Indicator M3 T1 P N F1 F2 F3 F4 Bypass and indicator settings Bypass valve No bypass No bypass Indicator bar 5. bar No indicator K M X When filter includes a bypass valve but not an indicator, code denotes bypass setting. + Box 8: code 2 + Box 8: code 2 Box 7 Filter connection Ports : Thread G 1 1 /4" 3-M : Thread G 1 1 /4 1 /2" 3-M G16 R2 G2 R24 Box 8 Options Standard No bypass Options 1 2 Media 2Q 5Q 1Q 2Q 2QH 5QH 1QH 2QH Media 2Q 5Q 1Q 2Q 2QH 5QH 1QH 2QH Replacement elements with nitrile seals -1 G1282Q G2721Q G1281Q G193Q G1442Q G3737Q G1441Q G1932Q -2 G1316Q G2724Q G1315Q G1938Q G1448Q G3738Q G1447Q G194Q -1 G169Q G2567Q G168Q G1946Q G1454Q G3739Q G1453Q G1948Q -2 G199Q G2727Q G198Q G1954Q G374Q G1459Q Replacement elements with fluoroelastomer seals -1 G132Q G2723Q G131Q G1934Q G4235Q G1445Q G1935Q -2 G1335Q G1942Q G1452Q G1451Q G1943Q -1 G189Q G188Q G195Q G1458Q G4237Q G1457Q G1951Q -2 G1119Q G2729Q G1118Q G1958Q G4238Q G1959Q Filter model Filter model Nominal flow (I/min) at viscosity 3 cst 2Q Seal kits S4233 S Q Fluoroelastomer S4234 S3522 1Q Q Highlights Key (Denotes part number availability) Note: Standard items are in stock, semi standard items are available within four weeks ßx(c)=2 5.% Degree of filtration Average filtration beta ratio ß (ISO 16889) / particle size µm [c] ßx(c)=1 ßx(c)=75 ßx(c)=1 ßx(c)=2 ßx(c)=1 % efficiency, based on the above beta ratio (ßx) 9.% % % % % Disposable 2Q 5Q 1Q 2Q High collapse element 2QH 5QH 1QH 2QH Note 1: Part numbers featured with bold highlighted codes will ensure a standard product selection. 18 FDHB5UK.
7 Indicators Series FMU p-indicators and Pressure Indicators Max 42 bar Measuring critical system parameters is essential Reliable and continuous control of the filter in all applications The FMU range of filter condition indicators are designed for use on a wide range of Parker filters and competitive interchange filters. Maximum pressure 42 bar. A comprehensive range of high quality indicators for mobile, industrial and marine applications. Contact Information: European Product Information Centre Freephone: (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: on a wide range of Parker filters. feedback FDHB5UK.
8 Indicators Series FMU p-indicators and Pressure Indicators Features & Benefits Features Indicators fatigue tested to full pressure rating Cartridge screw-in type indicators Visual, electrical and electronic indicators available Several indication settings Visual indicators Electrical indicator with change-over switch Electrical indicator with 4 LEDs Programmable and ATEX certified indicators available Advantages Reliable indicators for heavy duty applications Easy mounting Check element condition at a glance Right style for the application Optimized for each bypass setting Local monitoring of the element condition Option of Normally Open (N..) and Normally Closed (N.C.) function Thermal lock-out Visual early warning with yellow LED Pre-alarm with yellow LED and wired output Alarm with red LED and wired output Right indicators for special applications Benefits Reliable and continuous control of the filter in all applications Reliable sealing, no leakage Optimises element life, prevents bypassing Match your system s electrical connections Right indicator for application Reliable low cost indicator Approved for low voltage and high voltage use including machine control systems and PLC s No false alarm because of low temperature oil Allows time to schedule element change Indicates upcoming element change Clear indication for element change Improved machine surveillance Typical Applications Industrial equipment Mobile equipment Marine/offshore applications The Parker FMU Series Differential Pressure Indicators The FMU range of filter condition indicators, are designed for use on a wide range of Parker filters and suitable for competitive interchange (consult Parker Filtration for details). Ideal for giving accurate visual, electronic or electrical feedback of filter element condition, in order to facilitate effective maintenance and ensuring hydraulic systems, marine/mobile or industrial are protected from particulate contamination. 182 FDHB5UK.
9 Specification Maximum operating pressure: 42 bar (25 bar for aluminium). Maximum differential pressure: 21 bar. Working temperature range: -2 C to +85 C with fluoroelastomer seals, -4 C to +85 C with nitrile and EPDM seals. Material of housing: Brass, aluminium or stainless steel. Seals: Fluoroelastomer, or EPDM. Mounting torque: max. 75 Nm (max. 5 Nm for aluminium indicator body & filter housing) The differential pressure values of standard indicator models: 1.2 bar ±.2 bar ±.2 bar ±.3 5. bar ±.5 7. bar ± bar ±.5 (Indicators for other differential pressure values are optional). FMU p Indicators are typically used with the following filters: Heavy duty filters: GS, SF14, DF235, DF25, DFH26, DF27, DF289, DF211 Note: FMU-Block is required to connect indicator to filter. Medium pressure filters series: 45M. High pressure filters series: 7L, 7T, 7B, 5, 71 and 72. Heavy duty filter series: 13M, DF2145. High pressure filters without bypass valve: 7L, 7T, 7B, 71 and 72. Medium and low pressure filter series; Note for PD Range only bar indicators are available: 15CN, 4CN, 8CN,,, 15P, 3P, 4RF, 5RF, IL8, 12M, 22M, 16P, 26P, 36P. Also heavy duty filter DF4. High pressure filters 18P, 28P, 38P, FDA, FDB U12H U12H U12H U14M U14H 1. and bar bar 7. bar 1.2 and bar and 5. bar 183 FDHB5UK.
10 Indicators Series FMU p-indicators and Pressure Indicators FMUT Electrical Rated voltage Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load Inrush current (A) N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. 125VAC VAC VDC VDC VDC VDC VDC max. 1 max. Enclosure class IP65 Electrical connector DIN 4365 Overvoltage category II (EN611-1) Contact configuration P1-P2 Rotating part 36 COM Indication (N.O) Normally closed (N.C) No connect P1 high pressure P2 low pressure FMUM3 Visual Auto Reset/FMUM1 Visual Manual Reset Operation Red colour visible when indicator on U12H model ø24 M1-type push here for reset Operation U14M model Red colour visible when indicator on U14H model 6 Fixed part ¾-16 UNF-2A High pressure Low pressure /4-16 UNF-2A 32 Low pressure High pressure 7 /8-14UNF - 2A + + ø ø Note: Only FPUM3 visual auto reset available for models U14M and U14H. FMUM1 not available. 7 /8-14UNF - 2A 184 FDHB5UK.
11 FMUF Electronic Contact configuration U12H model NPN FMU F NPN Load Load +V Vdc Rotating part 36 4 V max 3 ma Green LED Yellow LED s PNP Red LED Fixed part A U12H U14M U14H A B C Ø16.2 Ø19.78 Ø18.83 ±.5 ±.6 ±.6 D 3 / / /8-14 UNF-2A UNF-2A UNF-2A FMU F PNP 3 1 Load +V Vdc High pressure B 4 2 Load max 3 ma Thermal lock-out (standard setting +2 C) Indicator operates only when temperature is above setting. Green LED is blinking if temperature is lower. (not in U12H) Ind. press. setting Enclosure class Electrical connector Input supply voltage *Indication output Output type: LED status G Y1 Y2 R < 5 % - 5 % - Note: Do not connect output terminals 1 or 2 directly (without load) to power supply terminals, because this will damage the equipment. FMUL1 Programmable Dimensions: see FMUF electronic p-indicator V Output 75 % 2 active 1 % 1 active Low pressure IP65 DIN 4365, cable connection PG9 or optinally M12 4-pin +1 to 36 Vdc max. 3 ma/36 Vdc N.O. or N.C./NPN or PNP C D U14M model C D B Low pressure High pressure U14H model Safety feature: The 25 bar U14M indicator does not fit into the U14H cavity, which is used in 42 bar filters Programmable p-indicator All settings adjustable (settings made via PC) Connections cable and software available from Parker 1 /2 years C D 185 FDHB5UK.
12 Indicators Series FMU p-indicators and Pressure Indicators Ordering Information Product configurator Box 1 Box 2 FMU M3 Box 3 K Box 4 V Box 5 M Box 6 U14 Box 7 H Box 8 Indicator series Filter monitoring unit FMU Box 2 Filter type Differential pressure indicator Visual manual reset Visual autoreset Electrical Electronic 4 LED, PNP, N.O. Electronic 4 LED, NPN, N.O. Electronic 4 LED, PNP, N.C. Electronic 4 LED, NPN, N.C. Programmable with memory logs Ex version M1* M3 T1 F1 F2 F3 F4 L1 X1 Box 3 Indicator setting 1. bar (14 psi) 1.2 bar (17 psi) bar (21 psi) bar (35 psi) 5. bar (7 psi) 7. bar (98 psi) 8.5 bar (125 psi) Standard settings: a: U14M, former -W3 b: U14H, former -W6 c: U12H, former -F6 Indicator setting Standard c a c a, b, c b c F G H K M N P Box 4 Seal material Fluorelastomer EPDM Neopren Seal type B V E N Box 5 Indicator body Indicator body Aluminium (Box 7, code M) Brass (Box 7, code M and H) Stainless steel A M R Box 6 Thread connection Thread connection 3 /4" - 16UNF-2A 7 /8" - 14UNF-2A U12 U14 Box 7 A - class products Max Pressure Max pressure CN, 15/3P & 22/32 PP Series 45M, 13M, 7P & 18/28/38P M H Box 8 Options Standard Other options Options omit factory supplied Note: F and L type indicators. Non-standard thermal lockout settings shown here. FMUX ATEX Approved Electronic Ø Cable 1 meter Specification: zone 1): Ex II 2 GD Eex m II T6 kmax : 1A Indicator type X1: ATEX p-indicator Electronic indicator accordant with ATEX 94/9/EC directive: (Ex) II 2 GD Eex mii T6. Degree of protection IP66. X1 refers to NPN, N.O. (see electronic F Type). Other output options are available by request. Connection cable + software for programmable indicator L1 Connection cable for PC serial connection and software for indicator settings and utilising memory logs. Ordering : Seal kits (fluoroelastomer) Ordering code Indicators with thread connection U12H (former -F6) Indicators with thread connection U14M (former -W3) Indicators with thread connection U14H (former -W6) HEX 24 (Ø 26.5 mm) 3/4-16UNF-2A U12H(F6) shape Note 1: Part numbers featured with bold highlighted codes will ensure a standard product selection. Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability. 186 FDHB5UK.
13 Pressure Indicators for Low Pressure Filters ETF Filter Visual pressure indicator G2 mm (inches) G 1 /8 48 Vdc electrical indicator 1. bar S2/S3 mm (inches) 31 (1.22) 25 VAC electrical indicator 1. bar S4 mm (inches) Rotating part 36 3 (1.18) x3 (1.18) 38 (1.49) 4 (7) 67 (2.64) HEX 24 (.94) 56 (2.2) 44 (1.73) C3 2 NO 1 NC 74 (2.91) 32 (1.26) 1 (.39) Option Description Connection/Voltage Wiring Part number G 1 /8K HEX 27 (1.6) G 1 /8K 1 (.39) Fixed part G2 Visual indicator 1. bar N/A N/A FMUG2EBPG2L S2/S3 Electrical indicator 1. bar 42 Vdc max Select either normally open (NO) or normally closed (NC) FMUS2FBMG2L (NO switch) or FMUS3FBMG2L (NC switch) Normally open contacts S4 Electrical indicator 1. bar 25 Vac max 1 NC 2 NO 3 C FMUS4FBMG2L TTF, BGT and TPR Indicator PS pressure switch Protective cap with dual cable duct for 1, 7-2, 3mm diameter cable Indicator PS NO/NC pressure switch Protective cover Normally open contacts 9 75 Amp 6.3x8 terminals Switch A/F 1 = COM. 2 = N.C. 3 = N.O. 24 A/F 9 Normally closed contacts 74 Normally closed contacts 55 G 1 /8 G 1 /8 (BSP) Ø3.5 Ø28 Elec.rating Thread connection Elec.connection Protection Specifications 42V / 4A G 1 /8 AMP 6.3x.8 terminals + protective cap IP65 (with cap) terminals IP FMUS14EBMG2 L (Switch) Specifications Elec.rating 42V / 2A Thread connection G 1 /8 Elec.connection AMP terminal 6.3x.8 Protection IP65 (terminal IP) Switch type NO or NC FMUS2EBMG2L (NO switch) FMUS3EBMG2L (NC switch) Visual indicator G 1 /8: code 1.2 bar FMUG2EBPG2L 187 FDHB5UK.
Indicators Series. FMU p-indicators and Pressure Indicators Max 420 bar. Measuring critical system parameters is essential.
FU p-indicators and Pressure Indicators ax 420 bar easuring critical system parameters is essential Reliable and continuous control of the filter in all applications The FU range of filter condition indicators
More information22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar
/ Series Max 26 l/min - 21 bar A duplex design with a wide application capability Designed to offer continuous operation during element change The / Series utilizes a duplex design with integrated balancing
More informationHigh Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters
P/3P Series MAX 2 I/min - 27 bar 9 High pressure filters P/3P Series Features & Benefits Features Compact aluminium housing Two head sizes and two bowl lengths Large ports and wide flow paths Microglass
More information12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-in filtration.
12CS Series Coreless Spin-on Filter Max. 7 l/min - 3 bar Environmentally friendly alternative for spin-in filtration Lightweight, non-metallic element that can be incinerated The 12CS Series features a
More information15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar
1/4/8CN Series Max. 6 I/min - 7 bar Premium performance for medium pressure applications FEATURING An economical multipurpose filter solution The CN Series utilizes a cast aluminium head and spin-on bowl
More informationETF Series. Tanktop Mounted Return Line Filters max. 175 I/min - 6 bar. An economic return line filter. Product Features: Contact Information:
max. 75 I/min - 6 bar An economic return line filter Improved system protection The ETF Series utilizes a re-inforced co-polymer head equipped with 2 return ports and quick-release cover. Maximum pressure
More informationMaxiflow Series Spin-on Filters Max. 360 I/min - 10 bar
Maxiflow Series Spin-on Filters Max. 36 I/min - 1 bar Designed for both suction and return application Spin-on filters The Maxiflow Series full flow filters for suction or return are designed to provide
More informationAN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features:
Max 5 I/min - bar Featuring prefiltration by means of a magnetic column Extended element life time AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF The TTF Series features pre-filtration by means of a magnet
More informationAN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features:
Max. I/min - bar When an all-in-one solution matters Reduction of reservoir accessories The Tanktopper Series features an integrated, micron Abs. air breather. Maximum pressure bar. Maximum flow l/min.
More informationATZ 300 (2 1 /2 SAE FLANGE) Empty Housing Flow (US GPM) p (PSID) p (bar)
Pressure Drop Curves The recommended level of the initial pressure drop for suction filters is.3 bar. If the medium used has a viscosity different from 32cSt, pressure drop over the filter can be estimated
More information(Ecological Pressure Filter)
EPF iprotect (Ecological Pressure Filter) High Pressure Filters Max 7 I/min - 45 bar A compact, cost effective pressure filter solution Designed with the iprotect patented filtration technology The Parker
More informationp (PSID) p (bar) p (PSID) p (bar) p (PSID) p (bar) Seals Element length Media rating (µ)
Pressure Drop Curves The recommended level of the initial pressure drop is ma.8 bar. If the medium used has a viscosity different from 3 cst, pressure drop over the filter can be estimated as follows:
More informationMedium Pressure Filters. 45M/45M Eco Series. MAX 260 I/min - 40 bar FEATURING. Medium pressure filters
/ Eco eries MAX 26 I/min - 4 bar FEATURING 8 Medium pressure filters / Eco eries Features & Benefits Features Cast iron head, steel bowl Reinforced Microglass III replacement elements Visual, electrical
More informationAN INNOVATIVE GREEN FILTER FEATURING
When an all-in-one solution matters Reduction of reservoir accessories LEIF AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF Contact Information: Hydraulic European Product Information Centre Freephone:
More informationPressure Switches Low Pressure Switch
Low Pressure Switch Measuring critical system parameters is essential Reliable and continuous control of the filter in all applications The Low Pressure range of filter condition indicators are designed
More information12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar
2CS Series Coreless Spin-on Filter Max. 7 l/min - 3 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The 2CS Series features a Parker,
More informationMedium Pressure Filters. 130 Eco Series. MAX 1000 I/min - 30 bar FEATURING. Medium pressure filters
13 Eco eries MX 1 I/min 3 bar FETURING 87 Medium pressure filters 13 Eco eries Features & Benefits Features Modular filter system Duplex type systems with selecting valve Bypass assembly in the filter
More informationTTF Series MAX 500 I/min - 10 bar
MX 5 I/min - bar N INNOVTIVE GREEN FILTER FETURING LEIF LEIF Low pressure filters Features & enefits Features bar rated filter Cast aluminium head LEIF elements Magnetic pre-filtration In-to-Out filtration
More informationTanktop Mounted Return Line Filters. ETF Series. MAX 140 I/min - 6 bar. Low pressure filters
Tanktop Mounted Return Line Filters ETF Series MX 4 I/min - bar Low pressure filters Tanktop Mounted Return Line Filters ETF Series Features & enefits Features Co-polymer head Multiple return line ports
More information7000 Series High Pressure Filters
7 Series High Pressure Filters Max 45 l/min - 42 bar FEATURING Global Filtration Technology 7 Series TYPICAL APPLICATIONS Forestry Equipment Industrial Power Units Pulp and Paper Port Handling Equipment
More informationHydraulic Filtration & Contamination Control Products. Brochure: FDHB200UK (Low Pressure Section)
Hydraulic Filtration & Contamination Control Products rochure: FDH2UK (Low Pressure Section) Consistent quality Technical innovation Premier customer service Hydraulic, Lubrication & Coolant Filtration
More informationSuction Return Series
Tanktop Mounted Suction & Return Line Filters - Types SR1 & MAX 25 I/min - 1 bar AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF 53 Tanktop Mounted Suction & Return Line Filters - Types SR1 & Features &
More information12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-on filtration.
Coreless Spin-on Filter Max. 75 l/min - 35 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The features a Parker, replaceable coreless
More informationGS Series. Medium Pressure Filters Max. 350 l/min bar. In-line peace of mind. Applications: Contact Information:
GS Series Medium Pressure Filters Max. 350 l/min. - 40 bar In-line peace of mind Three different housing sizes and several media options allow a wide range of applications. Cast iron housings are operable
More informationAN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features:
Max. I/min Flow from inside to out Designed for in-built filtration The IN-AGB Series features a quick response bypass construction with low hysteresis, magnetic prefiltration and a high dirt-holding capacity.
More information12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar
Coreless Spin-on Filter Max. 75 l/min - 35 bar Environmentally friendly alternative for spin-in filtration Lightweight, non-metallic element that can be incinerated The features a Parker, re-usable coreless
More informationMarine & Power Generation Filters. Brochure: FDHB173UK
Marine & Power Generation Filters Brochure: FDHB173UK Consistent quality Technical innovation Premier customer service Hydraulic, Lubrication & Coolant Filtration High-performance filtration systems for
More informationPortable Hydraulic Filtration Systems. Guardian. MAX 15 I/min - 2 bar. Portable filtration systems
Portable Hydraulic Filtration Systems Guardian MAX 5 I/min - 2 bar 37 Portable filtration systems Portable Hydraulic Filtration Systems Guardian Features & Benefits Features Portable and robust design
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request)
HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to
More informationHydraulic Filtration & Contamination Control Products. Brochure: FDHB200UK
Hydraulic Filtration & Contamination Control Products Brochure: FDHB2UK Consistent quality Technical innovation Premier customer service Hydraulic, Lubrication & Coolant Filtration High-performance filtration
More informationBy-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane
HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:
More informationDuplex Pressure Filters
Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical
More informationMPD Series. Medium Pressure Duplex
Medium Pressure Duplex 81 Applications of MPD Circulating Lube Oil Systems Power Generation Control Systems Steel Mill Control Systems Pulp & Paper Control Systems Test Stands Automotive Stamping Presses
More informationProcess & Chemical Fluid Filtration Liquid filtration systems for beverage, chemical and food processing; cosmetic, paint, fabrication.
Consistent quality Technical innovation Premier customer service Hydraulic, Lubrication & Coolant Filtration High-performance filtration systems for production machinery in industrial, mobile and military/marine
More informationConnection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to
More informationMPD Series. Medium Pressure Duplex
Medium Pressure Duplex 89 Applications of MPD Circulating Lube Oil Systems Power Generation Control Systems Steel Mill Control Systems Pulp & Paper Control Systems Test Stands Automotive Stamping Presses
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)
HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold
More informationFiltrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181
Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:
More informationPressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block
More informationMPD Series Medium Pressure Filters
Medium Pressure Filters 113 Applications - Circulating Lube Oil Systems - Power Generation Control Systems - Steel Mill Control Systems - Pulp & Paper Control Systems - Test Stands - Automotive Stamping
More informationPressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationHIGH PRESSURE FILTERS
HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
More informationHydraulic Filtration & Contamination Control Products. Brochure: FDHB200UK (Medium Pressure Section)
Hydraulic Filtration & Contamination Control Products Brochure: FDHB2UK (Medium Pressure ection) Consistent quality Technical innovation Premier customer service Hydraulic, Lubrication & Coolant Filtration
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst
More informationSystem20. Inline Sensors & Monitors. A proven method of accurate condition monitoring of a system. Product Features: Contact Information:
A proven method of accurate condition monitoring of a system Effective inline sensors and monitors for fluid condition monitoring Inline 0 sensors and hand-held monitors designed to give accurate and instant
More informationPressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)
HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:
More informationMPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min
MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 12 bar Flow rates to 3 l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for
More informationSPIN-ON FILTER - LOW PRESSURE LINE
SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises
More informationGlass-Filled Nylon and Metal Breathers IP65 Rated, Metal, Screw-on and Lockables Reservoir Equipment
Glass-Filled Nylon and Metal Breathers IP65 Rated, Metal, Screw-on and Lockables Compact and lightweight reservoir solutions IP65 Co-polymer breathers and metal breathers The IP65 rated range of moulded,
More informationA complete line of pressure differential visual and electrical indicators are available with this series of filters.
D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold
More informationHigh Pressure Filter Pi 4230
High Pressure Filter 4230 Nominal pressure 315 bar (4570 psi), nominal size 160 to 400 according DIN 24550 1. Features High performance filters for modern hydraulic systems Modular system Compact design
More informationMedium Pressure Filter Pi 340
Medium Pressure Filter Pi 340 Nominal pressure 250/315/350 bar (3560/4480/4980 psi), nominal size up to 450 (also available with filter elements acc. to DIN 24550) 1. Features. High performance filters
More informationHIGH PRESSURE FILTERS Series HF2P
HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,
More informationMedium Pressure Filter Pi 360
Medium Pressure Filter Pi 360 Nominal pressure /315 bar (2990/44 psi), nominal size up to 450 1. Features High performance filters for modern hydraulic systems Provided for pipe installation Modular system
More informationNFH Low Pressure Filters
PPLICTIONS NFH Low Pressure Filters Pressures to 360 psi Flows to 450 gpm Water Removal Capability 4 Ports HYDC NFH In-line Return Filters are designed for use on hydraulic power units, machine tools,
More information15P/30P Series High Pressure Filters
1P/P Series High Pressure Filters 124 1P/P Series Applications Saw mills Aircraft ground support equipment Asphalt pavers Hydraulic fan drives Power steering circuits Waste trucks Cement trucks Servo control
More informationDuplex Filter Pi Features. Nominal pressure 200/250 bar (2850/3560 psi), nominal size up to 450
Duplex Filter Pi 370 Nominal pressure 0/2 bar (28/3560 psi), nominal size up to 0 1. Features High performance filters for modern hydraulic systems _ Modular system Compact design Minimal pressure drop
More informationPressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )
HYDRULIC FILTRTION In line high pressure filters Technical Information Pressure: Max working 420 bar (6000 psi) (acc. to NFP T 3.10.5.1) Burst 1260 bar (18300 psi) (acc. to NFP T 3.10.5.1) Housing Connection
More informationHigh Pressure Filter Pi 410
High Pressure Filter Pi 410 Nominal pressure 315 bar (4480 psi), nominal size -63 1. Features High performance filters for modern hydraulic systems Provided for valve block installation Modular system
More informationSeries RFLD Duplex In-Line Filter
APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.
More informationTank Top Mounted Suction & Return Line Filters Types SR1 & SR2. Max 250 l/min - 10 bar. Brochure HYD001GB3
P495PAR SUCTION RETURN SERIES 9//3 9:37 am Page 5 Suction Return Series Tank Top Mounted Suction & Return Line Filters Types SR & SR Max 5 l/min - bar Brochure HYDGB3 R N EE R E GRING V I T U VA EAT O
More informationHPK04 Max Flow: 120 gpm (454 lpm)
HIGH PRESSURE FILTERS In-Line Cartridge Filters Working Pressures to: 6000 psi 41,380 kpa 413.8 bar Rated Static Burst to: Flow Range To: 17000 psi 117,300 kpa 1173 bar 120 gpm 454 lpm Features The high
More informationHigh Pressure Filter Pi 420
High Pressure Filter Pi 4 Nominal pressure 400 bar (5690 psi), nominal size up to 450 optional reverse flow valve 1. Features High performance filters for modern hydraulic systems Modular system Compact
More informationMedium Pressure Filter Pi 3000
Medium Pressure Filter Pi 3000 Nominal pressure /315 bar (3040/4570 psi), nominal size up to 400 according to DIN 24550 1. Features High performance filters for modern hydraulic systems Provided for pipe
More informationHigh Pressure Filter Pi 4000
High Pressure Filter Pi 4000 Nominal pressure 400 bar (5690 psi), nominal size up to 400 according DIN 24550 1. Features High performance filters for modern hydraulic systems Modular system Compact design
More informationFiltrec elements are tested also according to ISO 2942, ISO and ISO 3968
HYDULIC FILTTION F-1 series Spin-on filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFP T 3.10.17) Burst 20 bar (290 psi) (acc. to NFP T 3.10.17) Connection Ports: 3/4 1 1/2
More informationLow Pressure Filter Pi 2300
Low Pressure Filter Pi 2300 Nominal pressure 25/40 bar (360/570 psi), nominal size up to 1 Filter elements according DIN 24550 1. Features High performance filters for modern hydraulic systems Provided
More informationTank top return-line filter Pi 5000
MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Tank top return-line filter Pi 5000 Nominal size 160 up to 1000 according to DIN 24550 1. Features
More informationLine filter with filter element according to DIN 24550
Line filter with filter element according to DIN 2455 RE 51423/9.12 Replaces: 7.1 1/2 Type 445LEN4 to 1 Size according to DIN 2455: 4 to 1 Nominal pressure: 45 bar [6527 psi] Connection up to G 1 1/2;
More informationLow Pressure Filter Pi 2000/Pi 2200
Low Pressure Filter Pi 2000/Pi 2200 Nominal pressure 25 bar (360 psi), nominal size 630 up to 2000 according to DIN 24550 1 Features : HIgh performance filters for modern hydraulic systems Modular system
More informationIL8 Series. Medium Pressure Filters
Medium Pressure Filters 6 Applications for IL8 series filters Lube oil systems Power generation plants Test stands Primary metal equipment Pulp & paper equipment Offshore drilling and oil patch Flushing
More informationInline filter with filter element according to DIN 24550
Inline filter with filter element according to DIN 24550 RE 51421/07.11 Replaces: 12.10 1/16 Type 245LEN0040 to 400; 245LE0130, 0150 Size according to DIN 24550: 0040 to 0400 Additional sizes: 0130, 0150
More informationFPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need
FPK 02 AP280 Pressure Line High Pressure Filters In-Line up to 420 bar Mix&Match to Get What You Need Donaldson's Mix&Match system provides the great performance and functional advantages of custom-engineered
More informationSeries RFL In-Line Filter
APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction
More informationIL8 Series. Medium Pressure Filters
Medium Pressure Filters Applications for IL8 series filters Lube oil systems Power generation plants Test stands Primary metal equipment Pulp & paper equipment Offshore drilling and oil patch Flushing
More information12CS/50CS Series. Coreless Spin-on Filters
12CS/5CS Series Coreless Spin-on Filters 65 12CS/5CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.
More informationDuplex Filter Pi Features. Nominal pressure 25/63 bar (360/900 psi), nominal size up to 450
Duplex Filter Pi Nominal pressure 25/63 bar (360/900 psi), nominal size up to 450 1. Features.High performance filters for modern hydraulic systems Modular system Compact design Minimal pressure drop through
More informationLow Pressure Filter Pi 200
Low Pressure Filter Pi 0 Nominal pressure 25/63 bar (360/910 psi), nominal size up to 450 1. Features._ High performance filters for modern hydraulic systems Provided for pipe installation Modular system
More informationSPIN-ON FILTERS & ELEMENTS
ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic
More informationDuplex Filter Pi 3700
MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Duplex Filter Pi 3700 Nominal pressure 0/250/315 bar (2900/36/4570 psi), nominal size up to 400 according
More information50P Series High Pressure Filters
P Series High Pressure Filters 1 P Series Applications for P series filters Automotive specified equipment Hydrostatic transmission circuits Servo and proportional controls Offshore drilling rigs Mining
More informationLow Pressure Filter Pi 200
Low Pressure Filter Pi 0 Nominal pressure 32/63 bar (460/910 psi), nominal size up to 600 1. Features._ High performance filters for modern hydraulic systems Provided for pipe installation Modular system
More informationHigh Pressure Filter Pi 4230
High Pressure Filter Pi 4230 Nominal pressure 400 bar (5690 psi), nominal size 160 to 400 according DIN 24550 1. Features High performance filters for modern hydraulic systems Modular system Compact design
More information15/40/80CN Series Coreless Medium Pressure Filters
//8CN Series Coreless Medium Pressure Filters 89 //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment
More informationNFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports
NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports PPLICTIONS HYDC NFHD Return Line Filters are designed for use on hydraulic power units, machine tools, plastics injection
More informationDuplex Filter Pi 2100
Duplex Filter Pi 0 Nominal pressure 32/63 bar (460/900 psi), nominal size up to 400 according to DIN 24550 1. Features High performance filters for modern hydraulic systems Modular system Compact design
More information15/40/80CN Series. Medium Pressure Filters
//8CN Series Medium Pressure Filters 7 //8CN Series Applications for CN series Filters Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile
More informationDuplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100
Duplex Filter Pi 211 Nominal pressure 40 bar (570 psi), nominal size 800 and 1100 1. Features High performance filters for modern hydraulic systems Modular system Compact design Minimal pressure drop through
More informationBlock mounting filter, for vertical flange-mounting
Block mounting filter, for vertical flange-mounting RE 51417/12.1 Replaces: 7.1 1/18 Type 45PBFN4 to 1; 45PBF13, 15 Size according to DIN 2455: 4 to 1 Additional sizes: 13, 15 Nominal pressure 45 bar [653
More informationLow Pressure Filter Pi 230
Low Pressure Filter Pi 230 Nominal pressure 25/40 bar, (360/570 psi), nominal size up to 1400 1. Features High performance filters for modern hydraulic systems Provided for pipe installation Modular system
More informationHigh Pressure Filter Pi 422
High Pressure Filter Pi 422 Nominal pressure 400 bar (5690 psi), nominal size up to 450 optional reverse flow valve 1. Features High performance filters for modern hydraulic systems Modular system Compact
More informationLow Pressure Filter Pi 1500
Low Pressure Filter Pi 1500 Nominal pressure /25 bar (140/360 psi), nominal size up to 600 Filter elements according to DIN 24550 1. Features High performance filters for modern hydraulic systems Provided
More informationSRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction
Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar Technical Data Filter Elements Main Operating pressure up to 1000 kpa (10 bar). Static pressure testing up to 1500 kpa (15 bar). Back pressure
More informationLow Pressure Filter Pi 2000
Low Pressure Filter Pi 00 Nominal pressure 32/63 bar (460/900 psi), nominal size up to 400 according DIN 24550 1. Features.. High performance filters for modern hydraulic systems Provided for pipe installation
More informationDuplex Filter Pi 4700
MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Duplex Filter Pi 4700 Nominal pressure up to 315/350 bar (4570/4980 psi), nominal size 40 up to 400
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn