LIGHTING CONSTRUCTION MANUAL POLE BRACKETS MINOR ROAD
|
|
- Suzanna Allen
- 6 years ago
- Views:
Transcription
1 CONSTRUCTION MNUL POLE BRCKETS MINOR ROD Back to MIN INDEX Go to SECTION INDEX
2
3 WOOD POLE BRCKETS CONSTRUCTION TYPE Type shown within dashed box appears on relevant construction detail drawings in this manual. SL WPB/MI BC STREETLIGHT SL = Streetlight BRCKET WPB = Bracket CONNECTION BC = Service connection to LVBC Mains l = Service connection to luminium Mains Cu = Service connection to Copper mains SER = Supplied via BC Service BRCKET TYPE MI =.m Outreach, Minor Road MI = 3.0m Outreach.0m Uplift, Minor Road MI3 = 0.5m Outreach, Minor Road PT = 0.3m Outreach Type PT, Minor Road (Refer to Construction Drawing -7-8-) EXMPLE:- SLWPB/MIBC = Streetlight, Bracket, Minor Road Type.m Outreach, Service connection to LVBC mains. J. Brooks 4/0/0 POLE BRCKETS MINOR ROD - ERGON ENERGY ONLY R. English 4/0/0 CONSTRUCTION TYPE GUIDE BN BN HRD COPY UNCONTROLLED D. Taylor / B. Oyegoke 4/0/0 4/0/0 WOOD POLE MINOR ROD EE DRWG NO: -8-- EGX DRWG NO: VOLUME OLDER PGE 8-0
4 STREETLIGHT LUMINIRE MINOR ROD CONSTRUCTION TYPE Type shown within dashed box appears on relevant construction detail drawings in this manual. SL HPS 000 PRODUCT CODE 000 = Sylvania Suburban 70W HPS 000 = Sylvania Urban eroscreen 70W HPS 0003 = Sylvania Suburban 3W CL 0004 = Sylvania Urban eroscreen 3W CL 0005 = Sylvania Suburban 35W MH 0006 = Sylvania Urban eroscreen 35W MH 0007 = Sylvania Suburban 70W MH 0008 = Sylvania Urban eroscreen 70W MH 003 = Greenstreet T5 x 4W STREETLIGHT LED LUMINIRE MINOR ROD CONSTRUCTION TYPE Type shown within dashed box appears on relevant construction detail drawings in this manual. SLED GE 050 N LUMINIRE TYPE STREETLIGHT SUPPLIER IDENTIIER BILLBLE LOD N = Normal (semi cut-off) SLED = Streetlight LED GE = GE 050 = 5W STREETLIGHT LMP TYPE ND WTTGE SL = Streetlight HPS = High Pressure Sodium Vapour L = Linear luorescent CL = Compact luorescent MH = Metal Halide EXMPLE:- SL HPS 000 = Streetlight, High pressure sodium vapour, 70W EXMPLE:- SL MH 0005 = Streetlight, metal halide, 35W EXMPLE:- SLED GE 050 N = Streetlight LED, GE, 5.0W, Normal semi cut-off ORIGINL B C D REERENCE DRWING ENERGEX REERENCE DRWING ERGON BN BN HRD COPY UNCONTROLLED pproved Ergon pproved Energex. Zaini Checked P. Relf /. Bletchly 0/04/7 4/0/0 POLE BRCKETS MINOR ROD - ERGON ENERGY ONLY CONSTRUCTION TYPE GUIDE WOOD POLE LUMINIRE MINOR ROD EE DRWG NO: -8-- EGX DRWG NO: VOLUME OLDER PGE 8-0D
5 CONCRETE POLE BRCKETS CONSTRUCTION TYPE Type shown within dashed box appears on relevant construction detail drawings in this manual. SL CPB/MI SER STREETLIGHT SL = Streetlight BRCKET CPB = Concrete Bracket CONNECTION SER = Supplied via BC Service BRCKET TYPE MI =.m Outreach, Minor Road MI = 3.0m Outreach.0m Uplift, Minor Road EXMPLE:- SLCPB/MISER = Streetlight, Concrete Bracket,.m outreach, Minor Road, Supplied via BC Service. J. Brooks 4/0/0 POLE BRCKETS MINOR ROD - ERGON ENERGY ONLY R. English 4/0/0 CONSTRUCTION TYPE GUIDE BN BN HRD COPY UNCONTROLLED D. Taylor / B. Oyegoke 4/0/0 4/0/0 CONCRETE POLE MINOR ROD EE DRWG NO: EGX DRWG NO: VOLUME OLDER PGE 8-3 0
6
7 STREETLIGHT LUMINIRE MINOR ROD CONSTRUCTION TYPE Type shown within dashed box appears on relevant construction detail drawings in this manual. SL HPS 000 PRODUCT CODE 000 = Sylvania Suburban 70W HPS 000 = Sylvania Urban eroscreen 70W HPS 0003 = Sylvania Suburban 3W CL 0004 = Sylvania Urban eroscreen 3W CL 0005 = Sylvania Suburban 35W MH 0006 = Sylvania Urban eroscreen 35W MH 0007 = Sylvania Suburban 70W MH 0008 = Sylvania Urban eroscreen 70W MH 003 = Greenstreet T5 x 4W 0033 = Greenstreet T5 x 4W STREETLIGHT LED LUMINIRE MINOR ROD CONSTRUCTION TYPE Type shown within dashed box appears on relevant construction detail drawings in this manual. SLED GL 070 N LUMINIRE TYPE STREETLIGHT SUPPLIER IDENTIIER BILLBLE LOD N = Normal (semi cut-off) = eroscreen (full cut-off) SLED = Streetlight LED GE = GE GL = Gerard Lighting 070 = 7W 050 = 5W STREETLIGHT LMP TYPE ND WTTGE SL = Streetlight HPS = High Pressure Sodium Vapour L = Linear luorescent CL = Compact luorescent MH = Metal Halide EXMPLE:- SL HPS 000 = Streetlight, High pressure sodium vapour, 70W EXMPLE:- SL MH 0005 = Streetlight, metal halide, 35W EXMPLE:- SLED GL 070 N = Streetlight LED, Gerard Lighting, 7.0W, Normal (semi cut-off) ORIGINL B C REERENCE DRWING ENERGEX REERENCE DRWING ERGON BN BN HRD COPY UNCONTROLLED pproved Ergon pproved Energex. Zaini Checked P. Relf /. Bletchly 0/04/7 4/03/4 POLE BRCKETS MINOR ROD - ENERGEX ONLY CONSTRUCTION TYPE GUIDE WOOD POLE LUMINIRE MINOR ROD EE DRWG NO: EGX DRWG NO: VOLUME OLDER PGE 8-5 0C
8 MTERIL - BRCKET & SUPPLY SSY ORIGINL B C REERENCE DRWING ENERGEX pproved Ergon pproved Energex REERENCE DRWING ERGON. Zaini Checked BN BN DESCRIPTION QTY Bracket MI & cable, mounting to wood pole use holder 00 (service) to bracket Cartridge fuse link 3 HRC Saddle (0mm) to wood pole Bracket cable support to x-arm Connector Tap-off bare aluminium mains Connector Tap-off bare copper mains End cap - push on 5mm BC Connector I.P.C. 5/95mm main to 6/35mm tap luminium / 4-35mm Copper Thru Connector Conduit PVC flexible - 6mm. R HRD COPY UNCONTROLLED P. Relf /. Bletchly R R R MTERIL - LUMINIRE SSY DESCRIPTION QTY 87-3 S C3 87- H Luminaire normal lamp and PE cell H L L x 4W L R 900- x 4W L 87-7 S C Luminaire aeroscreen lamp and PE cell H H L7 D E /04/7 0/0/0 NOTES: conductors:- POLE BRCKETS MINOR ROD WOOD POLE.m OUTRECH TYPE MI - MTERIL EE DRWG NO: Bracket/Luminaire minimum clearance to L.V. = 00mm kv-kv-33kv = 00mm 66kV = 800mm Open wire conductor configuration depends on regional location - configuration shown is illustrative only. Provide a minimum clearance of 50mm between LVBC suspension or termination clamp and bracket mounting base. Bracket / Luminaire shall be mounted such that they are not contacting other pole top hardware eg, crossarms, arm braces, etc. LED Luminaires are only to be installed on approved brackets. Refer QPLDM for approved brackets. EGX DRWG NO: VOLUME OLDER PGE 8 3-0E
9 ssy Selection or 7 ssy intervals ssy 804- (EE) or ssy 804- (EGX) 300 ssy 805- (EE) ssy 803- ssy CONNECTION TO OPEN WIRE MINS Conductor clearance Refer note CONNECTION TO O/H SERVICE ssy ssy 803- Top Coachscrew ssy 8- ssy Selection 87-3, 7, 9 & to 5,, 3, 3 or 900- & 5 o ssy 804- (EE) or ssy 804- (EGX) ssy 803- Refer note ssy 80-6 ssy m mounting height 300 ssy CONNECTION TO LV BC MINS To ground surface To ground surface Construction Type SLWPB (Bracket) SL (Luminaire) SLED (LED Luminaire) ORIGINL B C 7..3 D E REERENCE DRWING ENERGEX REERENCE DRWING ERGON BN BN HRD COPY UNCONTROLLED pproved Ergon pproved Energex. Zaini Checked P. Relf /. Bletchly 0/04/7 0/0/0 POLE BRCKETS MINOR ROD WOOD POLE.m OUTRECH TYPE MI - CONSTRUCTION EE DRWG NO: EGX DRWG NO: VOLUME OLDER PGE 8 3-0E
10 MTERIL - BRCKET & SUPPLY SSY DESCRIPTION QTY Bracket MI & cable, mounting to wood pole use holder 00 (service) to bracket Cartridge fuse link 3 HRC Saddle (0mm) to wood pole Bracket cable support to x-arm Connector Tap-off bare aluminium mains Connector Tap-off bare copper mains End cap - push on 5mm BC Connector I.P.C. 5/95mm main to 6/35mm tap luminium / 4-35mm Copper Thru Connector ORIGINL B R R R Conduit PVC flexible - 6mm. R MTERIL - LUMINIRE SSY DESCRIPTION QTY Luminaire normal lamp and PE cell S70 C3 H35 H L L x 4W L x 4W L R S70 C Luminaire aeroscreen lamp and PE cell H35 H L7 C D E REERENCE DRWING ENERGEX pproved Ergon pproved Energex REERENCE DRWING ERGON. Zaini Checked BN BN HRD COPY UNCONTROLLED P. Relf /. Bletchly 0/04/7 0/0/0 NOTES: Bracket/Luminaire minimum clearance to conductors:- L.V. = 00mm EE DRWG NO: kv-kv-33kv = 00mm 66kV = 800mm Open wire conductor configuration depends on regional location - configuration shown is illustrative only. Provide a minimum clearance of 50mm between LVBC suspension or termination clamp and bracket mounting base. Bracket / Luminaire shall be mounted such that they are not contacting other pole top hardware eg, crossarms, arm braces, etc. LED Luminaires are only to be installed on approved brackets. Refer QPLDM for approved brackets. POLE BRCKETS MINOR ROD WOOD POLE 3.0m OUTRECH.0m UPLIT TYPE MI - MTERIL EGX DRWG NO: VOLUME OLDER PGE 8 4-0E
11 ssy Selection or 7 ssy intervals ssy 804- (EE) or ssy 804- (EGX) ssy 804- (EE) or ssy 804- (EGX) ssy ssy 805- (EE) ssy ssy ssy ssy 803- Conductor clearance Refer note 300 ssy 803- CONNECTION TO OPEN WIRE MINS CONNECTION TO LV BC MINS CONNECTION TO O/H SERVICE 5 o Top Coachscrew ssy Selection 87-3, 7, 9 & to 5,, 3, 3 or 900- & 7.5m mounting height ssy ssy 80-6 To Ground Surface ssy 80- To Road Surface Construction Type SLWPB (Bracket) SL (Luminaire) SLED (LED Luminaire) ORIGINL B C D E REERENCE DRWING ENERGEX REERENCE DRWING ERGON BN BN HRD COPY UNCONTROLLED pproved Ergon pproved Energex. Zaini Checked P. Relf /. Bletchly 0/04/7 0/0/0 POLE BRCKETS MINOR ROD WOOD POLE 3.0m OUTRECH.0m UPLIT TYPE MI - CONSTRUCTION EE DRWG NO: EGX DRWG NO: VOLUME OLDER PGE 8 4-0E
12 MTERIL - BRCKET & SUPPLY SSY DESCRIPTION QTY 845- Bracket MI3 & cable, mounting to wood pole use holder 00 (service) to bracket Cartridge fuse link 3 HRC Saddle (0mm) to wood pole Bracket cable support to x-arm Connector Tap-off bare aluminium mains Connector Tap-off bare copper mains End cap - push on 5mm BC Connector I.P.C. 5/95mm main to 6/35mm tap luminium / 4-35mm Copper Thru Connector ORIGINL B R R R Conduit PVC flexible - 6mm. R MTERIL - LUMINIRE SSY DESCRIPTION QTY Luminaire normal lamp and PE cell S70 C3 H35 H L L x 4W L R 900- x 4W L S70 C Luminaire aeroscreen lamp and PE cell H35 H L7 C D E REERENCE DRWING ENERGEX pproved Ergon ,. pproved Energex REERENCE DRWING ERGON. Zaini Checked BN BN HRD COPY UNCONTROLLED P. Relf /. Bletchly 0/04/7 0/0/0 NOTES: Bracket/Luminaire minimum clearance to conductors:- L.V. = 00mm EE DRWG NO: kv-kv-33kv = 00mm 66kV = 800mm Open wire conductor configuration depends on regional location - configuration shown is illustrative only. Provide a minimum clearance of 50mm between LVBC suspension or termination clamp and bracket mounting base. Bracket / Luminaire shall be mounted such that they are not contacting other pole top hardware eg, crossarms, arm braces, etc. LED Luminaires are only to be installed on approved brackets. Refer QPLDM for approved brackets. POLE BRCKETS MINOR ROD WOOD POLE 0.5m OUTRECH TYPE MI3 - MTERIL EGX DRWG NO: VOLUME OLDER PGE 8 5-0E
13 ssy Selection or 7 ssy intervals ssy 804- (EE) or ssy 804- (EGX) 300 ssy 805- (EE) ssy 803- ssy CONNECTION TO OPEN WIRE MINS ssy 845- Conductor clearance Refer note ssy Selection 87-3, 7, 9 & to 5,, 3, 3 or 900- & CONNECTION TO O/H SERVICE ssy 804- (EE) or ssy 804- (EGX) ssy ssy 803- Top Coachscrew 5 o ssy 803- Refer note ssy 80-6 ssy m mounting height 300 ssy CONNECTION TO LV BC MINS To ground surface To ground surface Construction Type SLWPB (Bracket) SL (Luminaire) SLED (LED Luminaire) ORIGINL B C D E REERENCE DRWING ENERGEX ,. REERENCE DRWING ERGON BN BN HRD COPY UNCONTROLLED pproved Ergon pproved Energex. Zaini Checked P. Relf /. Bletchly 0/04/7 0/0/0 POLE BRCKETS MINOR ROD WOOD POLE 0.5m OUTRECH TYPE MI3 - CONSTRUCTION EE DRWG NO: EGX DRWG NO: VOLUME OLDER PGE 8 5-0E
14 MTERIL - BRCKET & SUPPLY SSY DESCRIPTION QTY 80- Cartridge fuse link 3 HRC 80-6 use holder 00 (service) to bracket Connector I.P.C. 5/95mm main to 6/35mm TP 6-35 luminium / 4-35mm Copper Thru Connector 805- End cap - push on 5mm BC Bracket MI & cable mounting to wood pole Bracket MI & cable mounting to wood pole Bracket for insulating street light to concrete pole NOTES:. Bracket/Luminaire minimum clearance to conductors:- L.V. = 00mm kv-kv-33kv = 00mm 66kV = 800mm. Ensure a minimum of 50mm clearance is maintained between the concrete pole and fittings and the street light bracket. MTERIL - LUMINIRE SSY DESCRIPTION QTY 87-3 S C3 87- H Luminaire normal lamp and PE cell H L7 3. LED Luminaires are only to be installed on approved brackets. Refer QPLDM for approved brackets L x 4W L 900- x 4W L 87-7 S C Luminaire aeroscreen lamp and PE cell H H L7 R ORIGINL B C D E REERENCE DRWING ENERGEX REERENCE DRWING ERGON BN BN HRD COPY UNCONTROLLED pproved Ergon pproved Energex. Zaini Checked P. Relf /. Bletchly 0/04/7 4/0/0 POLE BRCKETS MINOR ROD CONCRETE POLE.m & 3.0m OUTRECH TYPE MI & MI - MTERIL EE DRWG NO: EGX DRWG NO: VOLUME OLDER PGE 8 6-0E
15 5 o Refer note on assy 836 Top Coachscrew (.m outreach) (3m outreach) To To Ground Ground Surface Surface ssy 804- (EE) or ssy 804- (EGX) ssy 805- (EE) ssy 80-6 ssy 80- ssy 836- Concrete pole NOTE: ll bands to be double wrapped ssy Selection 87-3, 7, 9 & to 5,, 3, 3 ssy Selection or 900- & 8- or (Refer detail B & note ) 7.5m mounting height To Road Surface 0 C L Drill to 85 suit bracket DETIL B DETIL Insulation Drilling Detail (000 x 50 x 00) SL Construction Type SLCPB (Bracket) (Luminaire) ORIGINL B C REERENCE DRWING ENERGEX REERENCE DRWING ERGON BN BN HRD COPY UNCONTROLLED pproved Ergon pproved Energex. Zaini Checked P. Relf /. Bletchly 0/04/7 /0/4 POLE BRCKETS MINOR ROD CONCRETE POLE.m & 3.0m OUTRECH TYPE MI & MI - CONSTRUCTION EE DRWG NO: EGX DRWG NO: SLED (LED Luminaire) VOLUME OLDER PGE 8 6-0C
LIGHTING CONSTRUCTION MANUAL PE CELL CONVERSION
CONSTRUCTION MNUL Back to MIN INDEX Go to SECTION INDEX TYPE DESCRIPTION PGE TYPE DESCRIPTION PGE Construction type guide - PE Cell conversion - Ergon Energy Minor road overhead mains supply Minor road
More informationLIGHTING CONSTRUCTION MANUAL CONTROL WIRING
CONSTRUCTION MNUL CONTROL WIRING Back to MIN INDEX Go to SECTION INDEX TYPE DESCRIPTION PGE TYPE DESCRIPTION PGE Zellweger Streetlight Relay Bo Layout & Wiring Details 33 Streetlight Contactor Bo Layout
More informationDISTRIBUTION DESIGN CATALOGUE
DISTRIBUTION DESIGN CATALOGUE Section 12 SL Street Lighting HPC-1DC-07-0012-2014 For application to Horizon Power Electricity Distribution Networks Document Control Author Name: Paul Savig Position: Senior
More informationItem Code Description Unit Qty Total
UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories
More informationLIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016
No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979
More informationNA2XSEKY 3 x (25-300) mm² 3.6/6 kv
NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5
More informationDocument No Amendment No Approved By Approval Date Review Date NS119 STREET LIGHTING DESIGN AND CONSTRUCTION
Network Standard NETWORK Document No Amendment No Approved By Approval Date Review Date : : : : : NW000-S0037 0 Chief Engineer 01/04/2015 01/11/2016 NW000-S0037 NS119 STREET LIGHTING DESIGN AND CONSTRUCTION
More informationDISTRIBUTION DESIGN CATALOGUE
DISTRIBUTION DESIGN CATALOGUE Section 16 UM Unmetered Supply HPC-1DC-07-0016-2014 For application to Horizon Power Electricity Distribution Networks Document Control Author Name: Paul Savig Position: Senior
More informationCONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ROADWAY LUMINAIRES
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 617 SEPTEMBER 1984 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ROADWAY LUMINAIRES 617.01 SCOPE 617.02 REFERENCES 617.05 MATERIALS TABLE OF CONTENTS
More informationOUTDOOR LIGHTING
15 00 00 01 Sheet 1 of 1 TABLE OF CONTENTS GENERAL INFORMATION HID LAMPS PHOTOCONTROLS LUMINAIRE COMPONENTS HID NEMA HEAD LUMINAIRE COMPONENTS HID HORIZONTAL LUMINAIRE COMPONENTS LED BRACKET MOUNT LUMINAIRES
More informationP High Voltage Catalogue Cables Australia Powering your Project
P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated
More informationURD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail
Part 5 LV Underground Drawing Register Number U8 U9 Description URD Mini Pillar Installation Guide UDS Universal Pillar Installation Guide U10-1 UDS Universal Pillar Double Link Unit Drilling Detail U10-2
More informationOVERHEAD CONSTRUCTION MANUAL
OVERHEAD CONSTRUCTION MANUAL Section Materials Quick Reference Approved by: A Smith-de Pere Energex Limited 214 ABN 4 78 849 55 DOCUMENT NUMBER: 492-A4 LAST UPDATE: 27/2/214 APPLE 6/113. 8372 APPLE 6/113.
More informationUrgent Support to the Agriculture and Electricity Sector in the Gaza Strip
Project Number: PAL -10-00063805 Project Name: Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Bill of Quantities Package # 2 LOT 2: Supply of Electrical Materials The contract
More informationWELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)
WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,
More informationSYSTEM PROTECTION - PLATING
INTRODUCTION 1. Plates F1 thru F10 supply only the material required for one-phase. Therefore, for threephase construction, you will be required to call for the specified plate three times at that station.
More informationCENTRE FEED UNIT UP TO 4000A. Safety
CENTRE FEED UNIT UP TO 000A Safety Centre feed unit New TCC section busbar: Connection options with CRITO PowerClip and CRITO ProfiClip, and terminal studs (screw in c-slot). 1-pole, side busbar support
More informationAPPENDIX B: LISTS OF APPROVED MATERIALS
APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete
More informationOVERHEAD DESIGN MANUAL
OVERHEAD DESIGN MANUAL Section 4 Poletop Constructions Approved by: F ZAINI ENERGEX 2018 MANUAL 00302 CONSTRUCTION SELECTION General Notes 1. Constructions should be selected according to: spanning and
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationNA2XSEKRY 3 x (25-300) mm² 3.6/6 kv
NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95
More informationSpecifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale
S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:
More informationCONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION
Page 1 of 11 R1 ****This Standard Supercedes CE Macros MPR1S, MUR1S, MPR3S & MUR3S and portions of BECo Standards CS2.7-1.1, CS2.7-1.5 & CS2.7-1.7**** PRIMARY URD RISER CONSTRUCTION TABLE OF CONTENTS Page
More informationIndex Section 103 Joint Use. General Requirements for Installation of Attachments on Oncor Poles
103 09-17 103 Index Section 103 Joint Use Title Date Number General Requirements for Installation of Attachments on Oncor Poles... 103-100 Supply and Communication Space... 103-105 Communication Lines
More informationAGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS
Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This
More informationBRACKETS, MOUNTS & HARDWARE
HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,
More informationSINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions
More informationCRITO Connection technology. Double and triple T and TCC section busbars
Centre feed unit 5 Centre feed unit Centre feed unit 5 Centre feed unit up to 4000 A combines the advantages of high short-circuit capacity, drill-free mounting, brace terminal technology and clearly structured
More informationMINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates
MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS Larry Vogt Manager, Rates Minimum Distribution System What is MDS? MDS is an analysis module of the cost-of-service study in which distribution investment
More informationHA series the slim connectors
HA series the slim connectors RockStr inserts HA series the slim connectors When spce is tight, the smll nd nrrow HA series comes into its own. Technicl dt Stndrds / pprovls Stndrds DIN EN 61984 Approvls
More informationNA2XSEY 3 x (25-300) mm 2 3.6/6 kv
NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0
More informationAGNES SCOTT OBSERVATORY - SOLAR
GNES SCOTT OBSERVTORY - SOLR ELECTRICL NOTES ELECTRICL REQUIREME PV SYSTEM NOTES Roof-Mounted Installation 6kW W N S E MTERILS ND METHODS REVISION NUMBER - FOR CONSTRUCTION REVISION HISTORY DESCRIPTION
More informationInstallation Manual Streetlight
Installation Manual Streetlight 600176 12/2014 Components for installation in box Strip 10mm of the cable insulation of charge controller, LED-Driver, battery and module Tools as required Cut off battery
More informationWisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power
Wisconsin Public Utility Institute June 28, 2017 Minimum Distribution Charges Larry Vogt Director, Rates Mississippi Power 1 Costs of Service vs. Cost Recovery Residential Service Example Assuming that
More informationIn-line Plug-in Design 3NJ6
Contents Page - Outgoing Feeders General 6/2 Structure and Functions inclusive Forms of Internal Separation, Installation of Instruments 6/2 Plug-on Bus System 6/2 Cable Connection Compartment 6/2 Switch-disconnector-fuse
More informationN2XSEFGbY 3 x (25-300) mm² 3.6/6 kv
N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0
More informationLIST OF PUBLISHED STANDARDS
Report : 08-0-6 Page o : Of 5 LST OF PUBLSHED STDRDS Total Count: 78 umber SS umber pproved mendment SBS/TC 066 SS 97:07 7.0 Electric cables - mpregnated paper-insulated 07-0-7 metal-sheathed cables for
More information3900 BOLLARD SERIES.
BY 3900 BOLLARD SERIES The 3900 Bollard Series was designed to light landscapes, pathways and high traffi c areas. The bollards feature lamp housings that minimize water and dust infi ltration, keeping
More informationWPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl Catalog Number Manufacturer Description Weight per unit Product
More informationService to Communication Equipment on PG&E Owned Steel Streetlight Poles with Antenna Provisions
SUMMARY This bulletin illustrates the service requirements for the specifically designed steel streetlight pole that is to be used when communication antenna attachments are needed. This bulletin also
More informationAFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
More informationFor mounting. cutouts, power fuses, arresters, capacitors, terminations, conduit EQUIPMENT MOUNTS
For mounting cutouts, power fuses, arresters, capacitors, terminations, conduit EQUIPMENT Index Introduction.... 1 Typical Installation.... 2 Aluminum Three Phase Cutout & Arrester Mounts.... 3 Aluminum
More informationMirroStar HOLOPHANE THE MIRROSTAR LUMINAIRE COMBINES SUPERIOR PERFORMANCE WITH EASE OF MAINTENANCE TO PROVIDE A UNIQUE SOLUTION FOR AREA LIGHTING.
OLOPNE MirroStar TE MIRROSTR LUMINIRE COMBINES SUPERIOR PERFORMNCE WIT ESE OF MINTENNCE TO PROVIDE UNIQUE SOLUTION FOR RE LIGTING. TIS COMBINTION OF PREMIUM OPTICL PERFORMNCE ND DURBLE CONSTRUCTION MKE
More informationAFL FLOODLIGHT SERIES
AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum
More informationRATE SLM PUBLIC STREET AND HIGHWAY LIGHTING
1 of 10 AVAILABILITY Available to any county or municipality in which the Company operates the local electric distribution system or to the State of Alabama for service along any highway adjacent to an
More informationOUTDOOR LIGHTING
15 00 00 01 Sheet 1 of 1 TLE OF CONTENTS GENERL INFORMTION HID LMPS PHOTOCONTROLS LUMINIRE COMPONENTS NEM HED LUMINIRE COMPONENTS HORIZONTL LUMINIRE COMPONENTS LED RCKET MOUNT LUMINIRES LUMINIRE COMPONENTS
More informationTABLE OF CONTENTS 1. GENERAL LABOUR COSTS EQUIPMENT COSTS...2
TABLE OF CONTENTS 1. GENERAL...2 2. LABOUR COSTS...2 3. EQUIPMENT COSTS...2 4. DISTRIBUTION MATERIAL COSTS (EDS AND OIL AND GAS FIELD SERVICE MODELS)..3 5. STREET LIGHTING...3 6. TRANSMISSION LINES...3
More informationLow-Voltage Motors N-compact Standardline Operation on supply system
Low-Voltage Motors N-compact Standardline Operation on supply system 2 2/2 Overview 2/2 Benefits 2/2 Technical specifications 2/2 Selection and Ordering Data 2/ Options 2/ Dimensional drawings 2/4 More
More informationCustomer Requirements Clearance Requirements for Overhead Joint Utility Construction
Application This standard establishes the clearances that are required on utility pole structures between electrical supply facilities owned and operated by Tacoma Power and communication facilities owned
More informationProduct Description. MASTER HPI-T Plus. Benefits. Features. Application. Versions. Quartz metal halide lamps with clear outer bulb
Lighting Product Description MASTER HPI-T Plus Quartz metal halide lamps with clear outer bulb Benefits High safety and comfort level, maintained over life Minimal maintenance cost Initial investment saving
More informationProduct Description. MASTER HPI-T Plus. Benefits. Features. Application. Quartz metal halide lamps with clear outer bulb
Lighting Product Description MASTER HPI-T Plus Quartz metal halide lamps with clear outer bulb Benefits High safety and comfort level, maintained over life Minimal maintenance cost Initial investment saving
More informationConstruction and Connection of Street Light Assets
Construction and Connection of Street Light Assets 1. INTRODUCTION... 2 2. FURTHER INFORMATION... 3 3. DEFINITIONS... 3 3.1 Designer... 3 3.2 Street Light Asset Owner... 3 3.3 Road Owner... 4 3.4 Developer...
More informationCABLE TERMINALS
14 00 00 01 Sheet 1 of 1 TABLE OF CONTENTS LOCATION & PLACEMENT OF RISERS ON JOINT USE POLES STANDOFF BRACKET PLACEMENT AND GROUNDING ONE RISER WITH U GUARD, 2, 3, 4, & 5 SPLIT CONDUIT OR SCHEDULE 40 0
More informationUncontrolled Document When Printed. Public Lighting Design Manual
Public Lighting Design Manual Table of Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Foreword... 4 Purpose and Scope... 6 Definitions, Abbreviations and Acronyms... 7 References... 9 Basic Lighting Concepts...
More informationIndex. Aluma Form, ALUMA-FORMEQUIPMENT MOUNTS Inc. WORLD S MOST COMPLETE LINE
Aluma Form, Index ALUMA-FORMEQUIPMENT MOUNTS Inc. Introduction.............................. 3 Typical Installation......................... 4 Aluminum Three Phase Cutout & Arrester Mounts..........................
More informationINDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01
INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01 Page LED Roadway Lighting Atlas Basic LED Roadway...1-2 ROADWAY LIGHTING Atlas LED Roadway...3-4 Atlas Evo LED Roadway I...5-6 Atlas Evo LED Roadway
More informationMODEL OF CHILLER MAC 036 FOR BTU. PARTS LIST
THA 006 PL-MAC06-STD000 MODEL OF CHILLER MAC 06 FOR 6000 BTU. PARTS LIST MULTIAQUA, INC. 0 S.W. 5 AVENUE, SUITE #0 MIRAMAR, FLORIDA 0 U.S.A. Tel: (95) -00 Fax: (95) -0 email: support@multiaqua.com www.multiaqua.com
More informationCORE AND COIL, DRY CAPACITOR, BRACKET, IGNITOR, MOUNTING HARDWARE 3-15/16 INCH L X 2.13 INCH W X 2-3/16 INCH H
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 llenwatson@elliottelectric.com LU70MULTIKIT Hid Ballast Sylvania-Ledvance Catalog Number Manufacturer Description Weight
More informationArena-Walsall power track system standard
standard Standard track length SL12 Standard feeder unit SFU Standard tap-off SO3U Standard SFB 1 Dimensions and technical information (p. 198-199) wo bar and earth 63 power track system Pack Cat. Nos.
More informationFebruary suspension connector. b Rotate t. the suspension connector to allow a counterbalance
VERSTILE T5 CEILING SUSPENSION SYSTEM CEILING SUSPENSION February 2005 DS-V07-EU Remove the plug from the fixture using a screwdriver. FITMENT OF SUSPENSION CONNECTOR FOR BEM CONTROLLER a Screw base to
More informationCG42T4 AUGUSTA. Luminaire. Optics. Sources Lamp 4K = High power LED 4000 K (neutral white) ± 150K.
CG42T4 St-Amable, Quebec Round shape. Acorn Style with hard top and cupola. Frosted globe, dent resistant, UV resistant. : Frosted acrylic : Frosted polycarbonated Tool-free "Twist-lock" quarter-turn opening
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationAmount (Rs) 1.5 sq. mm ISI marked, FR
BILL OF QUANTITY FOR ELECTRICAL WORK AT ESI REGIONAL OFFICE, STAFF QUARTERS, SEC-16 AND ASSOCIATED BRANCH OFFICE AND DISPENSARY. Part-II Sr. no SOR No. Details of Items Unit Quantity Rate (Rs) Amount (Rs)
More informationN2XSEBY 3 x (25-300) mm² 3.6/6 kv
N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,417 35 41.0 2,865 50 44.0 3,391 70 48.0 4,272 95 51.5 5,266 120 55.5 6,232
More informationN2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv
N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv Cu / XLPE / AWA / PVC (, XLPE Insuled, Aluminium Wire Armor, ed) 25 16.6 503 35 17.7 612 50 19.5 783 70 21.5 1,014 95 23.5 1,280
More informationA R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S
T A B L E O F C O N T E N T S A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S LLF755 - Low Level Flood with Anti-Glare Faceplate C1.1 LLF800 - Low Level Flood with Anti-Glare Faceplate
More informationSECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS
CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION
More informationBallasts For High Intensity Discharge Lamps
allasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity
More informationROOF. design: Laura Andreini
526 / 527 ROOF design: Laura Andreini ROOF recessed Body Light sources Power supply Components Sheet steel body with anodized sheet aluminium reflector with smooth or ribbed finish. TC-D, TC-DE compact
More information3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards
ALPHA 400 - DIN Wall-Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards (Flat Pack) /6 8GK1 surface-mounting distribution boards Pre-Assembled Unequipped Distribution Boards /7
More information1. G.T.A. Photo Electric Cells
1. G.T.A. Photo Electric Cells PHOTO ELECTRIC CELLS AND BASES AMP RATING FIXING METHOD TERMINALS QUANTITY LC-105 10 THROUGH HOLE IN FITTING WIRE TAILS 1 $33.00 LC-10D 10 TWIST INTO LC-10R BASE 3 PIN PLUG
More informationNightscape High performance floodlights and spotlights for discharge lamps
Nightscape High performance floodlights and spotlights for discharge lamps Nightscape is a range of floodlights and spotlights which offers new possibilities for the architectural illumination of buildings.
More informationSECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS
03.00 GENERAL CONSTRUCTION NOTES PRIMARY CONSTRUCTION PRIMARY CONSTRUCTION PIN INSULATOR INSTALLATION 03.00-02 03.00-04 03.00-20 03.02 CONNECTORS AUTOMATIC SPLICE INSTALLATION 03.02-01 INSTALLATION GUIDE
More informationMSR SERIES MSR RACK MOUNTING ENCLOSURE FEATURE. CAD data is downloadable from our web. Available in 16 sizes. Screws are not appeared on the surface.
MSR SERIES MSR RACK MOUNTING ENCLOSURE CAD dt is downlodble from our web. Avilble rnge -30 FEATURE Avilble in 16 sizes. Screws re not ppered on the surfce. Esy to punching or hole milling on front nd rer
More informationVoltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]
Open condensing units with air condenser and semi-hermetic compressor Galvanized and painted in RAL7035 base Semi-hermetic compressor Air condenser unit with 4 poles fans 230/1 Vibration absorber on discharge
More informationBEECHCRAFT [PRESSURE GYRO SYSTEMS ONLY]
1 2 3 4 24 25 20 6 7 8 9 5 10 13 14 15 16 22 23 21 18 11 12 17 19 28 27 26 pplicability: BEECHCRFT [PRESSURE GYRO SYSTEMS ONLY] Drawing: FC-W304 36 [S/N E-716, E-732 & fter] Date: 06/01/05 [S/N CE-602
More informationInsulated Street and Highway Lighting Mechanical Connectors Insulated connectors for above-ground applications.
Lighting Mechanical Connectors Insulated Lighting Mechanical Connectors Insulated connectors for above-ground applications. Rubber Insulation Ensures an insulated connection. Models with Street Light Connectors
More informationSPECIFICATIONS FOR COMMERCIAL CONSTRUCTION
Roseville Electric SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION REVISED 06/28/18 Commercial Construction Specifications Revision List REVISION Date Page No. Description 03/01/00 4.2-4.3 Changed leveling
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationEnergy Recovery Ventilator
PEG1610044CE Version:1601 Service Mnul Energy Recovery Ventiltor (North meric Mrket) WRNING This service informtion is designed for experienced repir technicins only nd is not designed for use by the generl
More informationSXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations
SXPJ SERIES HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division 1, Groups E, F & G Class III Zone 1, Groups IIA & IIB Factory
More informationSECTION 8 - SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS
08.00 GENERAL DISTRIBUTION SURGE ARRESTERS 08.00-0 CUTOUTS AND ARRESTERS GENERAL 08.00-03 08.0 CUTOUTS AND ARRESTERS METAL OXIDE ARRESTERS WITH POLYMER HOUSINGS 08.0-0 APPLICATION OF DIRECT CONNECTED ARRESTERS
More informationFirst Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO.
First Revision of Sheet No. 11.1 P.S.C.U. No. 50 Canceling Original Sheet No. 11.1 ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 11 STATE OF UTAH Street Lighting Company-Owned System AVAILABILITY:
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationTG/RB/2M/Web Rev.12/1/16. Pipe Hangers & Devices
TG/RB/2M/Web Rev.12/1/16 Pipe Hangers & Devices Pipe Welcome Hangers to PHD & Devices Manufacturing PHD Manufacturing, Inc. was founded in 1972 by a group of industry veterans with strong management, financial,
More informationN2XSERY 3 x (25-300) mm² 3.6/6 kv
N2XSERY 3 x (25-300) mm² 3.6/6 kv N2XSERY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 41.0 3,102 35 43.5 3,587 50 48.0 4,576 70 52.0 5,579 95 55.5 6,642 120 59.5 7,711
More informationPrismpack V, Prismalume V, Large Prismpack, Large Prismalume
AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER Holophane Company Inc. Field Service Department IMPORTANT SAFETY INSTRUCTIONS -READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OR MAINTAIN
More informationElectric Range installation manual
Electric Range installation manual This manual is made with 100% recycled paper. imagine the possibilities ENGLISH Thank you for purchasing this Samsung product. To receive more complete service, please
More informationHydraulic Pump. General description. Hydraulic circuit diagram
Hydraulic Pump SYSTEM 2 General description The hydraulically actuated grease pump BEKA HAMAX System 2 is mainly used to lubricate hydraulic hammers or other construction machinery accessories. Due to
More informationTYPE BILT DISCONNECT SWITCHES
TYPE BILT DISCONNECT SWITCHES OUTDOOR HOOKSTICK OPERTED (DISTRIBUTION CLSS) For sectionalizing and tap applications 7.5KV through 38KV 900 -- 40,000 momentary Furnished with hooks for loadbreak tool Used
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More informationTender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount
Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable
More informationMetropolitan Edison Company Rate RS - Residential Service Revenue Effects of Settlement Rates - FTY 12/31/17
Page 1 of 14 Rate RS - Residential Service CUSTOMER CHARGE 1 Customer Charge $10.25 5,936,304 $60,847,117 $11.25 5,936,304 $66,783,420 2 kw $2.59 18,053 $46,757 $2.72 18,053 $49,104 3 kwh $0.03599 4,898,972,415
More informationBILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH
BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH SL NO. DESCRIPTION OF ITEM / WORK UNIT QTY PART - A : ELECTRICAL WORKS 1 1 Energy Meter Cubicle : a Fabrication, Supply, Installation, testing
More informationDUNKIN DONUTS 206 EAST STATE STREET GENEVA, ILLINOIS
PRELIMINARY ENGINEERING PLANS DUNKIN DONUTS 206 EAST STATE STREET GENEVA, ILLINOIS ERIC CARLSON ARCHITECTS LOCATION MAP DRAWINGS INDE CONTACTS REV DATE NOT TO SCALE BENCHMARKS CRISSEY AVENUE IL ROUTE 38
More informationNew Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications
CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT New Panelboard for Lot H, EV Charger Energization, Las Positas College Scope of Work and Technical Specifications Chabot-Las Positas Community College District
More information34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE
4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER
More informationCTC 200 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers
WHEEL MONITOR CTC 200 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers Installation Manual for the CTC-200 Modules 2004 Wheel Monitor Inc. 1-905-641-0024 Page
More informationIMPACT FLOODLIGHT Architectural Flood Luminaire
IMPCT FLOODLIGHT rchitectural Flood Luminaire CLSSIC FORM + C O N T E M P O R R Y F E T U R E S ppealing round-back form combined with innovative design features make the Impact Flood series a best in
More informationHilti Strut Systems. * Fast - Efficient - Versatile * Easily intermixes with competitive strut. * Makes building electrical supports a snap
Hilti Strut Systems * Fast - Efficient - Versatile * Easily intermixes with competitive strut * Dimensionally the same as all major brands * Makes building electrical supports a snap Hilti Item # Hilti