Part Diagrams. HydraSwing 40/40F Actuator. Part Name Part Number HydraSwing Models (current) Mount, Gate. Valve, Brake. Pin, Cylinder.

Size: px
Start display at page:

Download "Part Diagrams. HydraSwing 40/40F Actuator. Part Name Part Number HydraSwing Models (current) Mount, Gate. Valve, Brake. Pin, Cylinder."

Transcription

1 HydraSwing 40/40F Actuator Mount, Gate Valve, Brake Pin, Cylinder Hose Kit Brake Manifold Bearing, Tapped Cylinder Kit (Primary or Secondary) Cylinder Kit Cover, Chassis Part Name Part Number HydraSwing Models (current) Bearing, Tapped, 1.25 inch MX all Brake Manifold Assembly, HydraSwing 40/40F/40 Twin LH MX /40F/40 Twin LH Brake Manifold Assembly, HydraSwing 40/40F/40 Twin RH MX /40F/40 Twin RH Cover, Chassis, Standard, HydraSwing 40/40F MX all Cylinder Kit, Position Sensing, 40/40F/40 Twin MX /40F/40 Twin (Primary) Cylinder Kit, without Sensor, 40/40F/40 Twin MX /40F Twin (Secondary) Hose Kit with Fittings, HydraSwing 40/40F MX3545 all Pin, Cylinder MX3058 all Valve, Brake MX all Price List 2018

2 HydraSwing 80F/150 Actuator Base Extension Mount, Gate Valve, Brake Pin, Cylinder Cylinder Kit Brake Manifold Bearing, Cup Hose Kit Cover, Chassis Cover, Front Part Name Part Number HydraSwing Models (current) Base Extension, HydraSwing 80F/150 MX all Bearing, Cup, HydraSwing 80F/150 MX3224 all Brake Manifold Assembly, HydraSwing 80F/150 LH MX F/150 LH Brake Manifold Assembly, HydraSwing 80F/150 RH MX F/150 RH Cover, Chassis, HydraSwing 80F/150 MX all Cover, Front, HydraSwing 80F/150 MX all Cylinder Assembly w/fittings, HydraSwing 80F/150 MX3548 all Hose Kit, HydraSwing 80F/150 MX3062 all Pin, Cylinder MX3058 all Valve, Brake MX all Price List

3 Pump Pack, Single Motor, Electric, AC Coupler, Motor Breather Cap Valve, Relief Sensor Kit, Inherent Entrapment Gauge, Pressure Quick Disconnect Socket Valve, Check, Endhead Valve, Directional Valve Coil, Directional Reservoir Price List 2018

4 Part Name Part Number HydraSwing Single Models (current) Breather Cap MX all Coupler, Motor, 5/8 inch Shaft, 6T MX all Gauge, Pressure, 3000 PSI, Kit MX all Motor, Electric, 60Hz, 2 hp, 3Ø, 3450 RPM, /460VAC MX all Pump Pack, HydraSwing 150 MX Pump Pack, HydraSwing 40 MX Pump Pack, HydraSwing 40F MX F Pump Pack, HydraSwing 80F MX F Quick Disconnect, Plug, 1/4 inch MX F/150 Quick Disconnect, Plug, 1/8 inch MX /40F Quick Disconnect, Socket, 1/4 inch MX F/150 Quick Disconnect, Socket, 1/8 inch MX /40F Reservoir, 4 Qt MX3475 all Sensor Kit, Inherent Entrapment MX all Valve Coil, Directional, 24VDC MX all Valve, Check, Endhead Main MX all Valve, Directional with Manual MX all Valve, Relief, 1500 PSI MX all Pump Pack, Single Price List

5 Pump Pack, Twin Motor, Electric, AC Coupler, Motor Breather Cap Valve, Relief Sensor Kit, Inherent Entrapment Flow Divider Manifold Gauge, Pressure Valve, Check, Endhead Valve, Directional Valve Coil, Directional Quick Disconnect Socket Reservoir Price List 2018

6 Part Name Part Number HydraSwing Twin Models (current) Breather Cap MX all Coupler, Motor, 5/8 inch Shaft, 6T MX all Gauge, Pressure, 3000 PSI, Kit MX all Motor, Electric, 60Hz, 2 hp, 3Ø, 3450 RPM, /460VAC MX all Pump Pack, HydraSwing 40 Twin MX Twin Pump Pack, HydraSwing 40F Twin MX F Twin Quick Disconnect, Plug, 1/8 inch MX /40F Quick Disconnect, Socket, 1/8 inch MX /40F Reservoir, 4 Qt MX3475 all Sensor Kit, Inherent Entrapment MX all Valve Coil, Directional, 24VDC MX all Valve, Check, Endhead Main MX all Valve, Directional with Manual MX all Valve, Relief, 1500 PSI MX all Pump Pack, Twin Price List

7 HydraSupply, Electrical Transformer Board, Display Board, Power Supply Keypad, Smart Touch Detector, Vehicle Cable, Ribbon Board, Smart Touch Switch, Disconnect Reset Switch, Internal Variable Frequency Drive Reset Button, External Hand Pump, HydraSwing 80F/150 Hand Pump with Hose Kit Price List 2018

8 Part Name Part Number HydraSwing Models (current) Board, Display MX3356 all Board, Power Supply, AC MX all AC Board, Smart Touch Controller MX all Detector, Vehicle, Hy5B MX4125 all Hand Pump Assembly, HydraSwing 80F/150 MX F/150 Hand Pump, Replacement Kit MX /40F/40 Twin Keypad, Smart Touch Controller MX3399 all Reset Button, External MX all Reset Switch, Internal MX all Switch, Disconnect MX all Transformer, 24VAC Output, 75VA, 60Hz MX all 60Hz AC except 575VAC Variable Frequency Drive Unit (VFD), Modbus, VAC, 50/60Hz, 1Ø/3Ø Variable Frequency Drive Unit (VFD), Modbus, VAC, 50/60Hz, 3Ø Variable Frequency Drive Unit (VFD), Modbus, VAC, 50/60Hz, 3Ø MX4210 MX4211 MX all 208,220,230VAC 50/60Hz input all 380,460VAC 50/60Hz input VAC, 50/60Hz 3 phase HydraSupply, Electrical Price List

Part Diagrams. Post (typical) Stabilizing Wire Rope Assembly. Part Name Part Number HydraLift Models

Part Diagrams. Post (typical) Stabilizing Wire Rope Assembly. Part Name Part Number HydraLift Models Post (typical) Sprocket Kit, Upper Stabilizing Wire Rope Assembly Sheave Motor, Hydraulic Limit Switch Sprocket Kit, Lower Part Name Part Number HydraLift Models Limit Switch MX000778 all Motor, Hydraulic,

More information

Bracket and Clamps, Wood Bracket, Breakaway Arm, StrongArm DOT. Bracket and Yoke, Non Counterweight Type. Bracket and Yoke, Counterweight Type

Bracket and Clamps, Wood Bracket, Breakaway Arm, StrongArm DOT. Bracket and Yoke, Non Counterweight Type. Bracket and Yoke, Counterweight Type Arm Hardware Bracket, Breakaway Arm w/kill Switch Kit Bracket and Clamps, Aluminum Bracket and Clamps, Fiberglass Bracket and Clamps, Wood Bracket, Breakaway Arm, StrongArm DOT Bolt Assembly, Shear Arm

More information

Installation Instructions

Installation Instructions Installation Instructions MX3635-01 Rev. E Models HydraSwing 40s HydraSwing 40F 4,000 lb (1,814 kg) 10-15 seconds HydraSwing 40 4,000 lb (1,814 kg) 15-20 seconds HydraSwing 40 Twin 4,000 lb (1,814 kg)/leaf

More information

10 PARTS LIST 10.1 Lift Assembly

10 PARTS LIST 10.1 Lift Assembly 10 PARTS LIST 10.1 Lift Assembly 30 10.2 Lift Assembly Parts List ITEM NO. QTY. DESCRIPTION PART NO. 1 1 DECK WELDMENT RHS 4-1091 1 DECK WELDMENT LHS 4-1090 2 54 BALL BEARING 6-2940 3 2 REAR SLIP PLATE

More information

Unpack. Left Handing (L) the Operator. StrongArmPark DC Breakaway Bracket Installation Video

Unpack. Left Handing (L) the Operator. StrongArmPark DC Breakaway Bracket Installation Video DC Left Handing (L) Standard. Factory ships left handing operator. NOTE: If your site requires right handing, place the order with your distributor as a StrongArmPark DC with right handing. Handing changes

More information

Premium Security and Reliability

Premium Security and Reliability Premium Security and Reliability a company of TheNiceGroup The Premium Slide Gate Operator The ultimate in quality and reliability Decades long life and low maintenance Move the longest, heaviest gates

More information

Order Form SwingRiser Twin (HRG 222) Gate Operator

Order Form SwingRiser Twin (HRG 222) Gate Operator Order Form SwingRiser Twin (HRG 222) Gate Operator Two posts operating two gate panels from one controller NOTE: If two gate panels or any part of the gate panels overlap each other when closed, each post

More information

Accessories STRA Room Controller

Accessories STRA Room Controller Accessories STRA Room Controller External temperature sensor, STRZ-5-b Technical data room sensor: STRZ-5-5 C PT, DIN class B IP Technical data external sensor: STRZ-5-2 - +7 C PT, DIN class B Technical

More information

PARTS ORDERING INFORMATION

PARTS ORDERING INFORMATION RP-268 REPAIR PARTS FOR VE268 Roll Grooving Tool PARTS ORDERING INFORMATION When ordering parts the following information is necessary for the Victaulic Tool Company to promptly process the order and send

More information

1.5. 7,250 psi Stainless steel V2A. 7,250 psi Stainless steel V2A. PUR cable type 3 IP 68 Embeddable 600 Hz Table 6 Diagram

1.5. 7,250 psi Stainless steel V2A. 7,250 psi Stainless steel V2A. PUR cable type 3 IP 68 Embeddable 600 Hz Table 6 Diagram 43 1 1 14,9 47 1 9 9 7 Max. operating pressure Sensing face HIGH-PRESSURE-RESISTANT P12 see page 7 see page 14 9 Compatible connectors DW-AD-01-P12-39 DW-AD-03-P12-39 DW-AD-01-P12-2 DW-AD-01-P12-27 DW-AS-01-P12-24

More information

Crest Heating Boilers FBN(L)

Crest Heating Boilers FBN(L) Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 59 IMG01113 52 65

More information

AFD-280U Parts List AFD-280U. (350 gm) (450 gm) (700 gm)

AFD-280U Parts List AFD-280U. (350 gm) (450 gm) (700 gm) AFD-80U (350 gm) (50 gm) (700 gm) I 0 Major Assemblies, AFD-80U AFD-80U Front View AFD-80U Parts List AFD -80U Front View ITEM P/N DESCRIPTION NO. FUNCTION 036 Hopper Lid Cover for the Fry Hopper. 99 Fry

More information

Your key to maximum design flexibility with seriesprogressive

Your key to maximum design flexibility with seriesprogressive Bulletin 10102 R MSP Modular Divider Valves Your key to maximum design flexibility with seriesprogressive reliability. IDEX CORPORATION LUBRIQUIP, INC., A Unit of IDEX Corporation 1995. All Rights Reserved.

More information

Section 10. Pressure Adjustments For: L90F-622 LUMBERJACK

Section 10. Pressure Adjustments For: L90F-622 LUMBERJACK Section 10 Pressure Adjustments For: L90F-622 LUMBERJACK 80-1009-047622 Rev 2/2013 Table of Contents Transmission Pressure Checks... 1 Accumulator Charge Pressure Adjustments... 2-3 Valve Adjustments...

More information

DME Valve Gate Controls

DME Valve Gate Controls DME ENERGY EFFICIENT, RELIABLE AND COMPACT HYDRAULIC AND PNEUMATIC CONTROLS 30 DME Valve Gate Controller Products and Solutions DME Valve Gate Controller Products and Solutions Solid-state timers and relays

More information

Crest Heating Boilers FBN(L)

Crest Heating Boilers FBN(L) Replacement Parts List S & SERVICE DEMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 2500-6000 69 67 59 62 79 18 26 66 76

More information

How to select parts to build an MX series progressive divider valve assembly, with NPT threading.

How to select parts to build an MX series progressive divider valve assembly, with NPT threading. How to select parts to build an MX series progressive divider valve assembly, with NPT threading. A simple MX assembly consists of these basic parts: 1. Inlet 2. Valve sections 3. End section 4. Tie Rods

More information

Miniature Intermediate Power Relay HY

Miniature Intermediate Power Relay HY Miniature Intermediate Power Relay HY A switching capabilities (C, C).kV dielectric strength (between coil and contacts) Various terminals, test button available Different sockets available to pole configurations

More information

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS kit Compact Change Over - 6-way switch valve with motor QUICK FACTS Enables heating & cooling in products with only one heat exchanger circuit Precise flow regulation For 4-pipe cooling/heating system

More information

Quick Start Guide SlideSmart DC HD25, HD30

Quick Start Guide SlideSmart DC HD25, HD30 Quick Start Guide SlideSmart DC HD25, HD30 Pad or post-mount electromechanical slide gate operator with Smart DC Controller 800-321-9947 253-867-3700 www.hysecurity.com Industrial Commercial Crash Parking

More information

ICSV3003 SALT AND SPREADER MODULE

ICSV3003 SALT AND SPREADER MODULE ICSV3003 SALT AND SPREADER MODULE 1 ICSV3003... Quality at low price The ICSV3003 valve has been manufactured in order to offer to spreader users a proportional electrohydraulic control that is precise

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information

Section 10. Cycle Times - Pressures - Adjustments For: L130F-109 LUMBERJACK

Section 10. Cycle Times - Pressures - Adjustments For: L130F-109 LUMBERJACK Section 10 Cycle Times - Pressures - Adjustments For: L130F-109 LUMBERJACK 80-1009-045109 Rev 1/2013 Table of Contents Cycle Times... 1 Pressure... 2 Transmission Pressure Checks... 3 Accumulator Charge

More information

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran 4 Project:_ Engineer:_ Mitsubishi Electric Automation, Inc. (MEAU) Variable Frequency Drives - HVAC System Submittal Summary Data Form NEMA 1 Bypass Systems Architect:_ Contractor:_ Submitted by: Date:

More information

INSTALLATION MANUAL. Drive line rebuild kit for MF class 8 p/n 13645

INSTALLATION MANUAL. Drive line rebuild kit for MF class 8 p/n 13645 INSTALLATION MANUAL 2011-05-09 Drive line rebuild kit for MF class 8 p/n 13645 Rekordverken k Sweden AB Öttum 535 92 KVÄNUM Tel. +46-511-303 00 Fax. +46-511-303 01 T0868 1 Foreword Description of rebuild

More information

HVH-100E ELECTRIC HYDROVECTION HELIX OVEN REPLACEMENT PARTS LIST

HVH-100E ELECTRIC HYDROVECTION HELIX OVEN REPLACEMENT PARTS LIST HVH-00E ELECTRIC HYDROVECTION HELIX OVEN REPLACEMENT PARTS LIST EFFECTIVE JULY 8, 0 Superseding All Previous s Lists. The Company reserves the right to make substitution in the event that items specified

More information

SVR10 SVA10. External Pilot air specification. Conventional specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

SVR10 SVA10. External Pilot air specification. Conventional specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized. Compact, yet keeps large capacity.» Limited space can be utilized. Standard.» SVR 10 series takes over the functions (Valve variations) of discontinued SVA 10 series. Pneumatic Symbols 1(P) 1(P) 1(P) 1(P)

More information

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv)

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv) Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/2 3300 Nl/min (3.35 Cv) Order code Series and function M-22-310-HN-12 Standard coils 1) 11 = 12 V DC,,2 W 12 = 2 V DC,,2 W 22 = 2 V AC,

More information

YG101 SWING GATE OPENER OWNER S MANUAL

YG101 SWING GATE OPENER OWNER S MANUAL YG101 SWING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the YG101 Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained technician.

More information

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) Installation Guide VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) VICPA222 Technical Data Power 24 Vac ±20%, 50/60 Hz Power consumption 8 VA (running)

More information

Identification Code: P 203-VDC with/without PCB V10-V13, H

Identification Code: P 203-VDC with/without PCB V10-V13, H Identification Code: P 0-VDC with/without PCB V0-V, H P0, P0 U with - outlets and 4 8 5 Y N = l transparent plastic = 4 l transparent plastic = 8 l transparent plastic = 5 l transparent plastic = reservoir

More information

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS MAGNITUDE LIGHTING C DIMMABLE DIM DOWN TO 1% CLASS 2 12V DC P/N: M20L12DC-AR Magnitude's M20L12DC-AR is the most compact LED driver on the market with a magnetic transformer core. It is equipped with two

More information

VALVES SERIES 70, SOLENOID/PNEUMATIC

VALVES SERIES 70, SOLENOID/PNEUMATIC VALVES SERIES 7, SOLENOID/PNEUMATIC TECHNICAL DATA Pressure range: monostable bistable asserved Minimum actuation pressure Operating temperature range Nominal diameter Conductance C Critical ratio b Flow

More information

Safety & Shut-off Blocks

Safety & Shut-off Blocks Safety & Shut-off Blocks Description HYDAC safety and shut-off blocks are designed to protect, shut-off, and discharge hydraulic accumulators or user units. The compact design simplifies the hydraulic

More information

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/

More information

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv) Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to 0.966 Cv) Order code Series and function KM-09-510-HN-442 Standard coils HN at ports 2 + 4 HN at ports 1, 3

More information

January 2018 PRICE SCHEDULE B 1.5 Maximum Security Slide Gate Operators

January 2018 PRICE SCHEDULE B 1.5 Maximum Security Slide Gate Operators Security Slide Gate Operators Section B1 This Price Schedule is effective January 1, 2018. Security Slide Gate Operators Date Page Comment 1-1-18 All January, 2018 Price Schedule update. 8-1-18 3 Added

More information

Fill cap with inlet strainer (40 mesh) Automatic approved quick connect inlet (no strainer)

Fill cap with inlet strainer (40 mesh) Automatic approved quick connect inlet (no strainer) GPO ubricator Motor-driven gear pump, Oil General The GPO ubricator is a motor-driven gear pump that is designed for use with single line centralized lubricating systems utilizing progressive distributors

More information

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves VFB30 Series Issue Date February 1, 2016 20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves Low Torque Facilitates the use of smaller, less expensive directmount rotary-motion actuators Extends

More information

Ionizer (Nozzle type) Series IZN10

Ionizer (Nozzle type) Series IZN10 262 Series IZN0 / Nozzle type (Nozzle type) Series IZN0 RoHS Slim and compact: 6mm thickness. Nozzle selectable: Energy saving, large flow types and female threads for piping. ±0V ion balance: High frequency

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS 582 HP OPEN CLOSE Wiring / Owner s Manual Use this manual for circuit board 02-010 Revision A or higher. 115 VAC Control Boxes for 6002, 600, 600 and 600 gate operators 02-065-E-5-12 CFORMS TO ANSI/UL-25

More information

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact: Solenoid operated EEx d IIC T6 Description of the Valve Directional control valves direct the flow in various directions (P A with 2/2 valves and P A // A T) with 3/2 valves. Available as 2/2 and 3/2 valves,

More information

2005 / 2012 / 2035 Series

2005 / 2012 / 2035 Series 005 / 0 / 035 Series Accessories Sandwich Pressure Regulators Accessory Description 0. to bar - 005 Regulator repair kit 0.3 to bar - 0.7 to 9 bar -3 0. to bar 39-909 0 Regulator repair kit 0.3 to bar

More information

Aldi V4 & V V1.1 5/23/2014

Aldi V4 & V V1.1 5/23/2014 Aldi V4 & V5 2012 2013 V1.1 5/23/2014 Aldi Control Techniques SK Series VFD & Hussmann MX Series MicroChannel Condenser Equipment Operation Component Orientation Control Wiring Programming and Start Up

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS MODEL SERIAL 58 HP CLOSE Wiring / Owner s Manual Use this manual for circuit board 0-010 Revision A or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT function.

More information

Hour Meter Series HM36

Hour Meter Series HM36 Robust design with high degree of Accuracy and Compact size Frequency independent for AC applications Indicates operating time in hours and tenths with running indicators Totally sealed from Dust and Moisture

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS MODEL SERIAL 8 HP DOORKING CLOSE Wiring / Owner s Manual Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT

More information

SOLENOID VALVES PIV.M 15 mm

SOLENOID VALVES PIV.M 15 mm SOLENOID VALVES PIV.M mm / NC/NO direct control microvalves Possible assembly on single and multiple bases Monostable manual actuation as standard Assembly in any position Operation with filtered lubricated

More information

VEHICULAR AC & DC. Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage

VEHICULAR AC & DC. Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage VEHICULAR AC & DC SWING GATE OPERATORS Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage AC & DC POWERED Gate OPERATORS Safety

More information

Accessories. Accessories Catalogue

Accessories. Accessories Catalogue Accessories Accessories Catalogue 1 Multi Line Accessories INDUSTRIAL Multi Line Accessories Pump Elements For XGS, AX and AC Pumps Blanking Plugs Fast Prime Kit AC Pump 78033 0.010cc Element Red 78034

More information

LR Resistance Heater Units

LR Resistance Heater Units 1 These instructions contain operating information and should be left with the unit. LR Resistance Heater Units Part List Edition 3.0 Installation in countries covered by EC Directives: This product will

More information

TWO-LINE ELECTRIC CHANGE-OVER VALVE

TWO-LINE ELECTRIC CHANGE-OVER VALVE TWO-LINE ELECTRIC CHANGE-OVER VALVE DPE APPLICATION Two-line electric change-over valves are necessary components of two-line central lubrication system circuits. They are usually connected after lubrication

More information

Installation instruction MicaFlex fume hood control. Fume hood control. Innehållsförteckning. Mi-212gb_

Installation instruction MicaFlex fume hood control. Fume hood control. Innehållsförteckning. Mi-212gb_ MicaFlex Flow 0.5 m/s ormal ormal Caution Alarm TEST ORMAL HIGH LOW FLOW FLOW FLOW RESET t s PGM ESC Keypad functions in programming mode Operator Monitor FHM catrone Installation instruction MicaFlex

More information

Model ET 5000W Operation and Service Manual

Model ET 5000W Operation and Service Manual Model ET 5000W Operation and Service Manual Patented 5/16 BALL Load Capacity: 5000 lbs The ET 5000W ESCALATE TRAILER offers ground level roll-on loading and roll-off unloading of equipment with non-tilting

More information

GLOSSARY OF TERMS, MAXON COLUMNLIFT (BMR)

GLOSSARY OF TERMS, MAXON COLUMNLIFT (BMR) GLOSSARY OF TERMS, MAXON COLUMNLIFT (BMR) 1. STRUCTURAL COMPONENTS: 6 Fixed Ramp A 6 Fixed Steel Ramp that attaches to the Folding Section of a two piece Platform or attaches to the Main Section of one

More information

Page 1 of 9 303-01C Engine 6.0L Diesel 2004 F-Super Duty 250-550/Excursion DESCRIPTION AND OPERATION Procedure revision date: 08/06/2003 Engine Printable View Engine Description The 6.0L diesel engine

More information

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv) Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/4 1300 and 1580 Nl/min (1.321 and 1.606 Cv) Order code Series and function M-07-310-HN-442 Standard coil HN at port 2 + 4 HN at port

More information

Components Parts of Quicklub Pumps P 223 and 233

Components Parts of Quicklub Pumps P 223 and 233 Components Parts of Quicklub Pumps P 223 and 233 6362b04 All rights reserved. Any duplication of this User Manual, in its entirety or in part, by whatever means is prohibited without the prior consent

More information

PH3300i Generator DTS Manufacturing, All rights reserved. PH3300i Unit PM, Rev < , v1.

PH3300i Generator DTS Manufacturing, All rights reserved. PH3300i Unit PM, Rev < , v1. PH3300i Generator 2016-2017 DTS Manufacturing, All rights reserved. PH3300i Unit PM, Rev < 2016-03-31, v1.1 > Page 1 of 5 PH3300i GENERATOR PARTS LIST 1 7504 69449 Engine Assy (177F) 33 03050298 66745

More information

Applications: Three-phase DC drive for regenerative and non-regenerative industrial applications from 1-1/2 to 600 Hp

Applications: Three-phase DC drive for regenerative and non-regenerative industrial applications from 1-1/2 to 600 Hp FlexPak 3000 Digital DC Drives DC & Controls Applications: Three-phase DC drive for regenerative and non-regenerative industrial applications from 1-1/2 to 600 Hp HVAC Features: Flexible design allows

More information

Lime Spreader. Model SL10. Illustrated Parts Breakdown. Hydraulic System Hydraulic Manifold. Twin Speed Reducer

Lime Spreader. Model SL10. Illustrated Parts Breakdown. Hydraulic System Hydraulic Manifold. Twin Speed Reducer Lime Spreader Model SL0 Illustrated Parts Breakdown Page Page Page Page Page Page Page Page Page Page 0 Front End Hydraulic System Hydraulic Manifold Switch Box Floor & Apron Axle Assembly Apron Drive

More information

Program Book/Guidelines for Graco Products

Program Book/Guidelines for Graco Products Program Book/Guidelines for Document No.: CL- F- Graco Version G 1.4 Page No.: 2 of 21 Document Management Information The controlled version of this document is the one stored on the GMPT Machinery and

More information

I23 RD P 16N 00

I23 RD P 16N 00 Sandwich Pressure Regulators ISO 1; ISO 2 and ISO 3 Series Overview How to Order: (example) I23 RD 1 00 0 P 16N 00 Regulator Port Series Size I12 = ISO 1 1/4 I23 = ISO 2 3/8 I34 = ISO 3 1/2 Regulator Type

More information

CRD610 Automatic Fitting Inserter

CRD610 Automatic Fitting Inserter CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/ Series 43000 Capsu-Photohelic Pressure Switch/Gage Specifications - Installation and Operating Instructions Bulletin B-34 Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT 4-3/8 [111.13] HOUSING REMOVAL 3-1/16

More information

Please read all instructions before operation!!

Please read all instructions before operation!! 1 Flow Rate: 8gpm Pressure Range: 0-2000psi RPM: 60 (load free) Torque: 600 ft lb HP: 13 Honda Engine Features: Auxiliary Flat Faced Male and Female Quick Disconnects Ship Weight: 510 lbs Reservoir Capacity:

More information

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend, Nugget 0 V0 Series Integrally Ported 5/2 and 5/3 Spool Valves Solenoid Actuated and Pilot Operated Ø, Ø mm or High flow from mm body width Low power solenoids with a range of voltages Use valves singly

More information

VALVES ISO 5599/1, SERIES IPV-ISV

VALVES ISO 5599/1, SERIES IPV-ISV VALVES ISO 5599/, SERIES IPV-ISV The assembly surface dimensions of ISO, ISO2 and ISO 3 valves are to ISO5599-. They are available in the 5-way versions with 2 and 3 positions and with pneumatic or solenoid

More information

Solenoid valves VZWM-L, NPT

Solenoid valves VZWM-L, NPT Key features and type codes General Indirectly actuated diaphragm valve Process valve connection N14 N2 Flow rate 1400 31000 l/min Available in brass or stainless steel casting Wide range of coils VZWM

More information

Mid Size Traction Unit

Mid Size Traction Unit FORM NO. 3319 398 ProLine Mid Size Traction Unit 14 H.P. Kohler Gear Drive Model No. 30177 695101 Thru 696000 Parts Catalog 3319 398 ORDERING REPLACEMENT PARTS To order replacement parts, please supply:

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

BIROTATIONAL POWER PACK

BIROTATIONAL POWER PACK HYDRAULIC SYSTEMS DIVISION Outstanding Hydraulic Products, Service and Expertise, Worldwide FEATURES / BENEFITS Reduces wiring, leak paths and eliminates directional valves resulting in lower overall system

More information

HYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics

HYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics HYDROMODEL-200 Transparent Hydraulics - Electro-hydraulics Hydraulic and electro-hydraulic technology at a glance Implements and controls hydraulic and electro-hydraulic circuits www.smctraining.com training@smctraining.com

More information

earth safe Fuel Systems for Critical Power

earth safe Fuel Systems for Critical Power Fuel System Control Valves 100 Solenoid Valves 110 Solenoid Valve Slow Close 120 Actuated Ball Valves 123 Actuated Ball Valves 3-Way 130 Actuated Butterfly Valves 140 Fire Safety Fusible Link Valves 145

More information

PART # DESCRIPTION 3670 ROLLER SEALER ASSY CARD ASSY - STA CONT 5412 GUIDE REAR INSERT CABLE CONTACT SPRING VALVE

PART # DESCRIPTION 3670 ROLLER SEALER ASSY CARD ASSY - STA CONT 5412 GUIDE REAR INSERT CABLE CONTACT SPRING VALVE PART # DESCRIPTION 3670 ROLLER SEALER ASSY 59319 4517 CARD ASSY - STA CONT 5412 GUIDE REAR INSERT 13506 CABLE 14213 CONTACT SPRING 17914 VALVE SOLENOID 24 VDC 20571 SWITCH ASSY 21370 327 BULB WEDGE BASE

More information

Industrial Relay KML(1C, 2C)

Industrial Relay KML(1C, 2C) Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS HFD/HFC SERIES FRYERS DRAWER FILTER SYSTEM HFD50F ML-135570 HFD85F ML-135574 HFC50F ML-135571 HFC85F ML-135575 WITHOUT DRAWER FILTER SYSTEM HFD50 ML-135551 HFD85 ML-135553

More information

Model 802 Center Mount Adapter For New Holland 9030 & TV140 Bi-Directional Tractors PARTS CATALOG

Model 802 Center Mount Adapter For New Holland 9030 & TV140 Bi-Directional Tractors PARTS CATALOG Model 802 Center Mount Adapter For New Holland 9030 & TV140 Bi-Directional Tractors 1 PARTS CATALOG TABLE OF CONTENTS Frame & Tractor Linkage...2,3 Header Linkage & Float Group...4,5 Header Drive Hydraulics

More information

RESIDENTIAL COMMERCIAL INDUSTRIAL HIGH SECURITY ANTI-RAM PARKING PERIMETER GATE SOLUTIONS. Residential to Crash

RESIDENTIAL COMMERCIAL INDUSTRIAL HIGH SECURITY ANTI-RAM PARKING PERIMETER GATE SOLUTIONS. Residential to Crash RESIDENTIAL COMMERCIAL INDUSTRIAL HIGH SECURITY ANTI-RAM PARKING PERIMETER GATE SOLUTIONS Residential to Crash Expect More 1500 Series Linear Actuator The Reliability Brands You expect unparalleled reliability

More information

Ariazone 5001 Automotive A/C Service Station

Ariazone 5001 Automotive A/C Service Station Ariazone 5001 Automotive A/C Service Station Spare Parts List Ariazone 5001 - Spare Part List 1 COMPONENT LOCATION AND IDENTIFICATION Ariazone 5001 - MODULES 1. Evacuation Pump 2.Recovery Pump 3. Oil Separator

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9 ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 9 (RTU1) CESMPU025REVAV9 Date: December 1, 2014 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV9 Unit features include: 25 ton MultiPath

More information

COMMERCIAL PARKING RESIDENTIAL HIGH SECURITY ANTI-RAM INDUSTRIAL HIGH SECURITY GATE SOLUTIONS. Residential to Anti-Ram

COMMERCIAL PARKING RESIDENTIAL HIGH SECURITY ANTI-RAM INDUSTRIAL HIGH SECURITY GATE SOLUTIONS. Residential to Anti-Ram HIGH SECURITY ANTI-RAM INDUSTRIAL COMMERCIAL PARKING RESIDENTIAL HIGH SECURITY GATE SOLUTIONS Residential to Anti-Ram SlideDriver with UPS backup a company of TheNiceGroup The Reliability Brand HySecurity

More information

KJ Main Components - 120V 60Hz. Jetter. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A.

KJ Main Components - 120V 60Hz. Jetter. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A. Jetter KJ-0 Main Components - 0V 0Hz 0 0 NOTE: Order parts by Catalog Number only. Decal, Potable Water 0 Decal, Model Number Decal, Warning Motor Shroud 0 Hand Grip Handle Cord Wrap Pan Head Screw, #

More information

BRAKE E

BRAKE E 8-1 GENERAL...8-2 SPECIFICATIONS...8-6 COMPONENTS...8-7 FRONT BRAKE...8-12 DISASSEMBLY INSPECTION REASSEMBLY (Pn1, Cu2 3 TON SERIES)...8-12 DISASSEMBLY INSPECTION REASSEMBLY (Pn2 3 TON SERIES)...8-17 BRAKE

More information

Section A1. Vehicular Gate Operators. This Price Schedule is effective June 1, Date Page Comment All June, 2016 Price Schedule update.

Section A1. Vehicular Gate Operators. This Price Schedule is effective June 1, Date Page Comment All June, 2016 Price Schedule update. June 2016 PRICE SCHEDULE A 2.0 Section A1 This Price Schedule is effective June 1, 2016. Date Page Comment 6-1-16 All June, 2016 Price Schedule update. Prices and specifications subject to change without

More information

Power Units and Valves

Power Units and Valves Power Units and Valves Page Power Units Valves, Mounting Kits & Manifolds Worksheet Features Gear Pump Vane Pump With Manifolds With D03 Manifolds Power Unit Matrix D03 Valves D03 Accessory Valves D03

More information

Safety & Shut-off Blocks

Safety & Shut-off Blocks SAF Series Safety & Shut-off Blocks Construction The Safety and Shut-off Block consists of a valve block, a built-in pressure relief valve, a main shut-off valve, and a manually operated bleed valve. In

More information

Illustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32

Illustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32 Illustrated Parts Guide DSD EDGE 120VAC Illustrated Parts Guide Page 1 of 32 This document is designed to provide a quick reference to the major replacement parts and components for the DSD EDGE. Parts

More information

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations. V5W Lubricator Automatic Continuous Operation The V5W Lubricator consists of a motor-driven gear pump, with a controlled bypass valve. (constant volume or constant pressure models) The fully automatic

More information

GROUP 11 HYD. PUMPS & VALVES

GROUP 11 HYD. PUMPS & VALVES GROUP 11 HYD. PUMPS & VALVES T944 EXTENDO PUMP INSTALLATION, FL-14490... 11-2 PUMP ASSEMBLY, LL-7500-11... 11-4 PUMP ASSEMBLY, LL-7500-11, (PUMP SECTION, LL-7501-15)... 11-6 PUMP ASSEMBLY, LL-7500-11,

More information

PW-E1S 5,000 psi 5HP ELECTRIC POWER UNIT OPERATION MANUAL

PW-E1S 5,000 psi 5HP ELECTRIC POWER UNIT OPERATION MANUAL PW-E1S 5,000 psi 5HP ELECTRIC POWER UNIT OPERATION MANUAL ON/OFF Switch High Pressure Supply Hydraulic Power Unit Shutoff Valves Low Pressure Return Breather Cap 5 HP Motor Optional Pump Hydraulic Fluid

More information

3000 psi (207 bar) Output/ min. 115 VAC 10cc (0.61 cu. in.) 24 VDC 12cc (0.73 cu. in.) Discharge Element Output Port.

3000 psi (207 bar) Output/ min. 115 VAC 10cc (0.61 cu. in.) 24 VDC 12cc (0.73 cu. in.) Discharge Element Output Port. MultiPort Lubricator Grease, Injector General The MultiPort Lubricator is an electrically driven multiple outlet lubrication unit design primarily for use with injector systems. The unit includes two pumping

More information

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor ACME SCREW LINEAR ACTUATOR Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore BA depth 17 Stroke end reed switches FCM Lenght Stroke 300

More information

Electric grease pump series L-EGP 230VAC / 400VAC

Electric grease pump series L-EGP 230VAC / 400VAC Electric grease pump series L-EGP / 400VAC The series L-EGP are electric driven grease pumps Activation and deactivation takes place via an external control unit. Reservoir made of transparent plastic

More information

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR FEBRUARY 14, 2001 REVISION 3 Publication: SE-125-M Document: S95-C125-00000 Printed in Canada. Copyright 2001 by Startco Engineering Ltd. All rights reserved.

More information

G3 PRIMO CAPPUCCINO SYSTEMS

G3 PRIMO CAPPUCCINO SYSTEMS G3 PRIMO CAPPUCCINO SYSTEMS TROUBLESHOOTING GUIDE MODELS: PCGT3, PCGT4, PCGT5, PCGT6 PCGT3 PARTS IDENTIFICATION FRONT VIEW CHASSIS VIEW HEATING TANK VIEW 3 18 19 5 4 20 22 1 2 11 12 13 14 8 9 10 15 16

More information

Tel: +44 (0) Fax: +44 (0)

Tel: +44 (0) Fax: +44 (0) SPX Bolting Systems SPX Center of Excellence UK Unit, Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 QW Tel: + (0) 60 5050 Fax: + (0) 60 50655 info@spxboltingsystems.com PELXX3L PEPXX3L

More information