1 COMPAIR Power
2 Ventilation technology COMPAIR Flexible system solutions remove your kitchen vapours COMPAIR stainless steel external blinds An eye-catcher on any outside wall Page COMPAIR flow 150 (system Ø 150) The range for top flow performance Page COMPAIR flow 125 (system Ø 125) Strong for fresh and waste air technology Page COMPAIR flow round 150 (system Ø 150) High in volume and easy to install Page COMPAIR flow round 125 (system Ø 125) High in volume and easy to install Page COMPAIR top (system Ø 125 flat) Powerful ventilation technology Page COMPAIR norm (system Ø 100) The range for a good indoor climate Page COMPAIR hoses Problem-free connection Page
3 Flexible system solutions remove your kitchen vapours They should be as inconspicuous as possible. Adjust to the variable pressure of high-performance fans in island and wallmounted hoods - and still look good. To fulfil all the technical air flow and architectural demands of modern exhaust and supply air you have to offer a wide range of highly flexible flat duct systems. COMPAIR systems with their specifically constructed diameter geometry are optimally constructed for exhaust air routing in kitchens with permanently low back pressure. This is the outcome of in-house developments and productions which are perfectly engineered down to the last detail. 188/13
4 The advantages of exhaust air technology in comparison to others... Recirculating air example The recirculating hood can be used in areas where exhaust air operation isn t feasible or only possible after expensive structural changes. As a kitchen sales expert, in individual kitchen planning, you should always mention to your clients that recirculating hoods aren t a good alternative to exhaust hoods. Stiftung Warentest's statement (test 8/2007) could be seen as an argument for the more effective use of exhaust hoods: "No charcoal filter can absorb cooking smells as effectively as an exhaust duct can extract them." The fact that recirculating hoods aren t at all able to clear the humidity in kitchen fumes is another problem which, with growing insulation awareness, can over time lead to mildew, which poses a health risk. With the COMPAIR range we offer you technically sophisticated air duct technology for individual exhaust air solutions when planning new constructions and refurbishments. While developing the products we made a point of being in constant dialogue with universities and research institutions. The focus was on harmonising the energy efficient usage of system parts with powerful exhaust hoods. 189/13
5 The advantages of exhaust air technology in comparison to others... Exhaust air example Reasons for exhaust air technology: Everything you need to know in a nutshell Smells, dampness and carbon monoxide (gas stoves) are almost completely diverted to the outside. Due to the removal of dampness the danger of long term health risks (allergies etc.) due to mildew infestation are reduced and also damage caused by condensed water can be avoided (i.e. swelling up of wooden surfaces). Given the same construction and volume flow, an exhaust hood combined with a fluidic adapted air duct/wall sleeve installation is much less noisy than a recirculating hood. The costs for the necessary changing of the activated carbon filter in a recirculating air system are much higher than for the installation of an exhaust duct including the wall sleeve (calculation basis 15 years/ 3 changes per year). Heat losses are minimised by the use of a wall sleeve, like the COMPAIR flow Star, that only opens when the cooker hood is in operation. Since during recirculating air operation extra ventilation is usually needed, the heat losses should be com - parable. The replacement air needed during the exhaust air operation can get to the cooking area through a window, door gap or another air supply opening*. *Secure air supply openings are always stipulated when an exhaust hood and an ambient air-dependent furnace are in - stalled in dwellings. The smallest solution is a contact switch, that automatically closes the exhaust hood when the window is closed. Alternatively, an electrical window drive that is controlled by the on/off switch of the exhaust hood can be installed. This avoids the window staying open constantly. 190/13
6 System Ø 150 COMPAIR flow 150 bion 150 The new size sets new performance standards A B C D E F Fitting example Deflector 90 with round pipe Ø 150 (F-UR 50/90) for Ø 150 hood connection Ventilation pipe (F-VRO 1000) Horizontal pipe bend 90 (F-RBH 90) Pipe connector (F-RVB) End piece (F-EST) Telescopic wall conduct (K-KLIMA-R 150/150) A Flat duct pipes 150 Page 199 Pipe connectors 150 Page 199 Pipe bends 150 Page Deflectors 150 Page C B End piece 150 Page 201 Flat duct sets 150 Page 201 External blind 150 Page 202 Wall sleeves 150 Page flow Star GTS 150 Page E-Klima A/Z 150 Page 206 Roof ventilator 150 Page Roof hoods 150 Page 207 B Plug-in connector 150 Page 207 Fastening clamp 150 Page 207 D Window contact switch Page Wall connector 150 Page 209 B Silencers 150 Page 209 Flat duct mounts 150 Page 209 C Round duct mounts 150 Page 210 Round pipes 150 Page 210 E B Pipe connectors Page 210 round 150 Reducer 150 Page 210 F Condensing water Page 210 separator 150 Duct tapes Page 210 Backpressure shutter 150 Page 211 Filter Page 211 Ventilation duct casing Page 212
7 150 COMPAIR flow bion 150 F-VRO 1000 Ventilation pipe 1000 mm More performance through "conduction" with guide vanes high speed flow speed (m/s) without guide vane 80 mm F-UR Deflector low speed uneven flow even flow Flow speed and pressure loss in comparison of systems with guide vanes without guide vane high pressure loss static pressure (Pa) As a result of the patented guide vane technology, vapour flows are smoothed in the duct and directed to the environment with very little loss of pressure. Using COMPAIR flow 150, up to 79 % less pressure is lost, depending on the length and structure of the waste air duct with a cross-sectional increase of only 2.9 %, compared with the 150 round pipe. F-RVB Pipe connectors F-Bion 150 Deflector low pressure loss F-UR Deflector with pipe 500 mm mm Energy efficiency for extremely powerfull hoods Bionik deals with the research and the systematic transfer of solutions from nature to technical applications. For COMPAIR bion the flow dynamics optimal meandering systems in watercourses formed the natural example. The development of the deflector was carried out using the latest simulation and measurement technology. Here, the focus was on the energy efficient use of the system parts with extremely powerfull hoods. F-RBV Round bend vertical Flow detachment No flow detachment High pressure loss F-RBH Pipe bend horizontal Low pressure loss All COMPAIR bion deflectors can also be subsequently integrated into existing systems taking the duct geometry into account. Using the modern COMPAIR flow 150 rectangular profile, freedom of design is retained in kitchen planning. The external system dimensions H 89 mm x W 222 mm and corner radiuses of 20 mm enable you to plan inconspicuously and in a space-saving way. Full range for top performance COMPAIR flow 150 by Naber is leading air duct technology, which you can order according to your requirements and on a consignment basis. Typical Naber: if the order quantity is 10 pc. or more, component sets can be put together individually according to your wishes F-EST End piece E-Jal flow External blind Strikingly unobtrusive form 198/ Flow speed and pressure loss in systems comparison stainless steel 222 i 89 i Klima-E 150 Wall sleeve with external blind /stainless steel K-Klima-R 150/150 Wall sleeve with external blind brown brick red
8 COMPAIR flow 150 (system Ø 150) Item/ Description Order no. unit COMPAIR flow 150 COMPAIR flow 150, with integrated guide vane technology, is the most advanced air duct system. COMPAIR bion 150 effectively conducts the exhaust air of extremely high performance hoods. COMPAIR flow 150 reduces pressure loss, optimises volume flow and protects the fan motor. COMPAIR bion 150 minimises noise development due to reduced pressure loss. COMPAIR flow 150 is recommended by leading manufacturers of kitchen hoods. F-VRO 1000 system 150 flat duct Ventilation pipe without sleeve. length 1000 mm F-RVB pipe connector For straight ventilation pipes (F-VRO 1000). length 80 mm F-RBH 150 pipe bend horizontal 90 With guide vanes and sleeves integrated on both sides F-RBH 150 pipe bend horizontal 15 With sleeve integrated on one side /13
9 COMPAIR flow 150 (system Ø 150) Item/ Description Order no. unit F-RBV 150 pipe bend vertical 90 With guide vanes and sleeves integrated on both sides F-RBFLEX 1 system 150 pipe bend For diversions and turns up to 180. Adapter, flexible, rectangular to rectangular, with integrated sleeve. length mm F-RBFLEX 2 system 150 pipe bend For diversions and turns up to 180. Adapter, flexible, round to rectangular, with integrated sleeve. length mm a a 295 Ø150i F-Bion 150 deflector 90 Energy efficient solution for extremely high performance hoods. For direct hood connection with integrated sleeve F-UR 150 deflector 90 For direct hood connection with guide vanes and sleeve integrated on one side F-UR 150 deflector 90 with round pipe Deflector 90 with guide vanes and round pipe. To achieve optimum flow performance, always use the deflectors with round pipe. Only use the deflectors with hose in exceptional cases, if no other engineering option exists (F-URX 500/F-URX 1000). F-UR 500 mm F-UR 900 mm /13
10 COMPAIR flow 150 (system Ø 150) Item/ Description Order no. unit F-URX 150 deflector 90 with flexi-hose Deflector 90 with guide vanes, flexihose and 2 hose clips. F-URX 500 mm F-URX 1000 mm F-EST 150 end piece With integrated sleeve for direct transition from flat to round (wall penetration). Optimised for flow Flow 150 flat duct set 1 With guide vanes. Set consisting of: 2000 mm flat duct pipe ( ) 1 x deflector with 900 mm round pipe ( ) 1 x connecting sleeve ( ) 1 x end piece/transition piece ( ) Flow 150 flat duct set 2 With guide vanes. Set consisting of: 3000 mm flat duct pipe ( ) 1 x deflector with 900 mm round pipe ( ) 1 x pipe bend 90, horizontal ( ) 2 x connecting sleeve ( ) 1 x end piece/transition piece ( ) /13
11 COMPAIR flow 150 (system Ø 150) Item/ Description Order no. unit K-Jal 150 external blind 190 x 190 mm, with backpressure shutter for connection to round pipes. Ø 150 a mm connector depth: 71 mm brown brick red E-Jal flow 150 external blind 290 x 160 mm with backpressure shutter for connection 222 x 89 mm to COMPAIR flow 150. connector depth: 120 mm stainless steel E-Jal 150 external blind Stainless steel external blind with backpressure shutter for connection to round pipe. connector depth 145 mm stl. st., Ø 150 a (190 x 190) mm E-Jal Blow 150 external blind Stainless steel external blind 190 x 190 mm with backpressure shutter and fly screen for connection to round pipe. connector depth: 145 mm stainless steel, Ø 150 a mm Klima-E 150 wall conduct With backpressure shutter, telescopic pipe and stainless-steel external blind. hose/pipe connector Ø: 150 a mm connector depth: 24 mm installation depth: mm wall penetration: about Ø 155 mm /stainless-steel Klima-E flow 150 wall conduct With backpressure shutter and stainless-steel external blind. With rectangular connector for COMPAIR flow 150. pipe connector: 227 a x 94 a mm connector depth: 80 mm installation depth: mm wall penetration Ø: about 155 mm /stainless-steel /13
COMPAIR flow Exhaust System. The powerful way to save energy!
The powerful way to save energy! 100 90 80 70 60 50 40 30 20 10 % 100 conventional bend flow 150 bend Deflector Horizontal bend Vertical bend 69 100 38 100 21 Comparison of pressure loss with the same
More informationRMHDT90SS/ - RMHDT100SS/ - RMHDT110SS/ Instructions Manual.
RMHDT90SS/ - RMHDT100SS/ - RMHDT110SS/ Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 8 MAINTENANCE... 9 2 RECOMMENDATIONS
More informationLEIHDS110SC/ LEIHDS110BC/ Instructions Manual.
LEIHDS110SC/ LEIHDS110BC/ Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 8 MAINTENANCE... 9 2 RECOMMENDATIONS AND
More informationFans & extraction cooker hoods must have the correct size ducting. Please refer to the manufacturers recommended specification.
Ventilation Extraction of stale air & condensation from bathrooms & kitchens is a must to stop damp and mould. Good quality ventilation is essential for ensuring that you adhere to building regulations.
More informationBuilding Integrated Duct System
Mounting instruction Building Integrated Duct System Description We are facing one of the toughest challenges in decades. New buildings and existing homes must minimize their use of energy. In less than
More informationInstructions for use and installation Cooker Hood
Instructions for use and installation Cooker Hood FTU 3807 WXS 70H FTU 3807-P WXS 70H Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS...18 CHARACTERISTICS...19 INSTALLATION...20 USE...24 MAINTENANCE...25
More informationEnergy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)
Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated, axial and roof fans, air handling units
More informationFume cupboards and extraction devices
Fume cupboards and extraction devices Energy efficiency, maximum ergonomics and a larger internal workspace make working with our new fume cupboards even safer and more convenient. A new design together
More informationMAKING MODERN LIVING POSSIBLE. Danfoss Air. Installation manual for Danfoss Air Flex duct systems DANFOSS HEATING SOLUTIONS
MAKING MODERN LIVING POSSIBLE Danfoss Air Installation manual for duct systems DANFOSS HEATING SOLUTIONS Index 1 Before you start...........................................................................
More informationINSTRUCTIONS FOR MAINTENANCE AND USE KITCHEN EXTRACTOR HOOD ZRW 50/60
INSTRUCTIONS FOR MAINTENANCE AND USE KITCHEN EXTRACTOR HOOD ZRW 50/60 Dear Customer You are now a user of a kitchen extractor hood of ZRW type. This hood has been designed and manufactured specially with
More information120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.
120 Ventilation Ventilation Removes smoke and odor. Adds exceptional style. Ventilation 121 Ventilation Bosch s efficient, highly effective ventilation products complete any Bosch kitchen package. Capable
More informationImproving your workspace
FILTERMAX DF FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive dust from other industries.
More informationSMOKE EXTRACTION VENTILATION FOR PARKING PREMISES
SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES 08 CONTENTS Smoke extraction systems page 4 JAF axial jet fans page 6 ICF impulse centrifugal fans page 0 Ventilation system for underroof parking page
More informationFresh air and exhaust air systems
Fresh air and exhaust air systems Fresh air and exhaust air systems Overview RECTANGULAR ROOF COWLS 1 2 3 4 5 6 7 Special versions on request 1 Jet cap DFH-E-Eco 5 Fresh air cowl ALH 2 Roof cowl DH 6 Discharge
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationbott vario Professional vehicle equipment for your Peugeot Bipper Partner Expert Boxer
bott vario Professional vehicle equipment for your Peugeot Bipper Partner Expert Boxer bott vario Feel at home in your Peugeot 2 You ve decided to get a Peugeot. In taking this decision you have created
More informationTecduct Plastic Ducting
lindab I the ventilation products specialist Tecduct Plastic Ducting Lightweight but robust construction. Easily cut to length. Manufactured from flame retardant, self extinguishing materials. External
More informationHoods for professional kitchens
Hoods for professional kitchens smarter ventilation Our kitchen hoods have been developed to provide the best possible comfort in all types of professional kitchens. But we haven t just satisfied ourselves
More informationUse. Installation. Key figures. Worth noting. linx industries chilled beams
89 Use Lindab's supply air beam can be used for cooling, heating and ventilation. Installation I-60 is installed into a false ceiling, and can be suspended by hangers or threaded rods. As standard is delivered
More informationEFC Instructions Manual
EFC 9542 Instructions Manual Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS...3 CHARACTERISTICS...4 INSTALLATION...5 USE...8 MAINTENANCE...10 EN 2 RECOMMENDATIONS AND SUGGESTIONS INSTALLATION
More informationGigaBox centrifugal fans Product specific information
GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,
More informationKH E, KH E
INSTRUCTIONS FOR USE Kitchen extractor hood Type: KH 17101 E, KH 17106 E Dear Customer!! You are now a user of the newest generation kitchen extractor hood of KH 17101, KH 17106. This hood has been designed
More informationNovenco axial flow fans. ZerAx - Standard January 2010
Novenco axial flow fans ZerAx - Standard January 2010 Product facts Product The Novenco ZerAx series of axial flow fans uses innovative design to reduce power consumption by improving efficiency. As an
More informationMX-ventilation products
MX-ventilation products Technical brochure ENG Material Weatherproof and impact resistant polypropylene UV protected Solid coloured Reliable and controlled ventilation High-quality and durable materials
More informationINDEX RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 6 INSTALLATION USE MAINTENANCE... 33
Instruction Manual INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 6 INSTALLATION... 20 USE... 31 MAINTENANCE... 33 2 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to
More informationTOP 10 NOISE CONTROL TECHNIQUES
TOP 10 NOISE CONTROL TECHNIQUES The following are 10 simple noise control techniques that have wide application across the whole of industry. In many cases, they will produce substantial noise reductions
More informationRVDRT & RVVRT Model 404 to 408
All-Star 00% Oil Free Rotary Vane Pump & Compressor RVDRT & RVVRT Model 0 to 08 0 0 0 ( version RVDRT* pcs ) 30 3 3 33 3 35 0 (version RVVRT ) 3 ( version RVDRT ) 50 60 ( version RVDRT ) 70 ( version RVVRT
More informationbott vario Professional vehicle equipment for your Mercedes-Benz Estate cars Vito Sprinter
bott vario Professional vehicle equipment for your Mercedes-Benz Estate cars Vito Sprinter bott vario Feel at home in your Mercedes-Benz 2 You ve decided to get a Mercedes-Benz. In taking this decision
More informationSMART Application Structure Acoustics s n fa f o o R
Application The SMART fans are designed for general ventilation of buildings. They are meant for forwarding dry air of maximum temperature +60 C, and dustiness not exceeding 0,3 g/m³, without viscous,
More information7 Services Control and monitoring
Control and monitoring 7 Services We are the only manufacturer of laboratory equipment who offers you fume cupboards and variable fume cupboard control all from one supplier. Benefit from our know-how
More informationKSEV97X. IT Libretto Istruzioni GB Instruction Manual. 11 FR Manuel d Instructions 20 DE Bedienungsanleitung 29 NL Gebruiksaanwijzing
IT Libretto Istruzioni 2 Instruction Manual 11 FR Manuel d Instructions 20 DE Bedienungsanleitung 29 NL Gebruiksaanwijzing 38 ES Manual de Instrucciones 47 KSEV97X Dear Customer, If you follow the recommendations
More informationDuct System for Danfoss Air Units
MAKING MODERN LIVING POSSIBLE Installation Guide for Danfoss Air Units www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation
More informationStoves and inserts CATALOGUE
Stoves and inserts CATALOGUE INSERTS INDEX INSERTS A-85 PLUS A-70 PLUS FREESTANDING STOVES NEW VISION G-100 A-85 Plus... 6 A-70 Plus... 6 G-100... 10 VISION... 12 FREESTANDING STOVES RA-85 Plus... 16
More informationSCHÄFER IT-Systems The specialists for IT infrastructure
SCHÄFER IT-Systems The specialists for IT infrastructure www.schaefer-it-systems.com 1 2 SCHÄFER IT-Systems The specialists for IT infrastructure SCHÄFER IT-Systems The specialists for IT infrastructure
More informationData sheet. Server Rack ( heavy duty rack cabinet ) W:800 = D:1000
Data sheet General description This is a unique server enclosure which is designed for housing heavy server & Networking systems, Server Rack cabinets are compatible with 19" rack mount equipment from
More informationFilter Hood Model CA-S
Model CA-S Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety,
More informationPRIMEX VENTING PRODUCTS AND ACCESSORIES
Index ACCESS PANELS... 14-15 DIFFUSERS CEILING AND SIDEWALL WG Series ADJUST-A-VENT... 14-2 WGX Series TRUE-FLOW VENT... 14-2 SQUEEZE ELBOW 90 EB4X90... 14-5 termination diffuser collars... 14-3 TRIM PLATEs
More informationPOWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL
POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL Copyright: April 7, 2014 Gripnail Corporation Revised: January 25, 2018 An Employee Owned Company 97 Dexter Road East Providence, Rhode Island 02914-2045
More informationSURE-SPRING SURE-SPRING, HP VERSION. ROLL-UP COVERS Special products. 18
SURE-SPRING The P.E.I. Patented design known as SURE-SPRING represent the most advanced level of technical innovation in the field of roll-up covers. (Patented) Suitable for HIGH SPEED operation The multiple
More information(Thin) (Ultrathin) Suspended Air-handling Unit
(Thin) (Ultrathin) Suspended Air-handling Carrier China Headquartered in Farmington, Connecticut, USA, Carrier Corporation is the world's largest provider of heating, air conditioning and refrigeration
More informationGmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02
GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 07/02 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches
More informationCentrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...
More informationOPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)
OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO 44677 (330) 669 2773 CONTENTS Section Description Pages 1 Introduction 3 2 External Features
More informationLock Junior Office Classic 48 50
junior office classic Junior Office Classic convince with timeless classic design. Engineered for high frequented doors, they achieve a large stress capacity. The numerous types fulfill variable requirements.
More informationMeasuring probe For ventilation and air-conditioning Model A2G-FM
Special For ventilation and air-conditioning Model A2G-FM WIKA data sheet SP 69.10 Applications Air flow measurement in circular ventilation pipes Air flow measurement in rectangular ventilation ducts
More informationCENTRIFUGAL FAN COIL UNIT VCE
CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical
More informationA I R C O M P R E S S O R S R O L L A I R E
A I R C O M P R E S S O R S ROLLAIR 75-100-125E E F F I C I E N C Y R E L I A B I L I T Y Superior quality & Performance The modern ROLLAIR compressor is the result of more than 30 years of continuous
More informationEDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM
AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation
More informationOverall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25
ON/OFF Professional hoods 48", 36" and 30" restaurant-style hoods 48", 36" and 30" tapered-sided hoods 48", 36" and 30" straight-sided hoods 30" under-cabinet hood ZV48RSFSS, ZV36RSFSS and ZV30RSFSS ZV48TSFSS,
More information211 Climate Control 219 PP HVAC (TWK)
211 Climate Control 219 PP HVAC (TWK) 8-30-02 1 These technical training materials are current as of the date noted on the materials, and may be revised or updated without notice. Always check for revised
More informationRoto NT The world s biggest selling Tilt&Turn hardware system for windows and balcony doors
Window and door technology Roto NT The world s biggest selling Tilt&Turn hardware system for windows and balcony doors For aluminium profiles with 16 mm hardware groove Convincingly good windows With surprisingly
More informationCeiling Mount Type Ventilating Fan
Ceiling Mount Type Ventilating Fan Introduction 11-12 DC Motor Series 13-14 Super Quiet Series 15-18 Standard Series 19 10 These fans are installed in the ceiling connected with ductwork, by which indoor
More informationOne platform for all electronic applications
ONE SYSTEM FOR ALL SOLUTIONS. One platform for all electronic applications An Electronics Packaging system with versatile capabilities that expands with evolving project requirements: VARISTAR offers innovative
More informationRoof Upblast and Sidewall Exhaust
XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and
More informationAir conditioning concepts for mini- and midibuses
Roof-top air conditioners Air conditioning concepts for mini- and midibuses It s clear to see what they do best: effective cooling on narrow roofs True climate comfort also for small buses Word has got
More informationLINEAR LS CHILLED / CERAMIC / BAIN MARIE
LINEAR LS CHILLED / CERAMIC / BAIN MARIE RF LSRF2 LSRF3 LSRF4 LSRF5 LSRF6 Deck forced refrigeration Canopy LED light Integral condensor Self evaporating Foam insulated double skin base 65mm deep full size
More informationChapter 4 Part D: Exhaust and emission control systems
4D 1 Chapter 4 Part D: Exhaust and emission control systems Contents Air inlet heating system components - removal and refitting...... 4 Catalytic converter - general information and precautions........
More informationMeasuring Instruments for Paper Machines. Temperature Relative Humidity Air Flow
Measuring Instruments for Paper Machines Temperature Relative Humidity Air Flow Instrument Temperature, Humidity, Air Flow Temperature Humidity Air Flow Temperature ONLY! SwemaTemp 20 is a display instrument
More informationPro-Line II Filing Frame
Pro-Line II Filing Frame Efficiency in the office. The Pro-Line II filing frame is the perfect solution for professional equipment of office cabinets. It combines innovative technology with highly functional
More informationrangehoods SA520TX90 90cm telescopic rangehood SA520TX60 60cm telescopic rangehood
Quiet, powerful and energy-efficient, Smeg s rangehoods are available in a diversity of styles from the discreetly concealed, to the boldly stated. With some of the most advanced air extractors in the
More informationPro-Line II Filing Frame
Pro-Line II Filing Frame Efficiency in the office. The Pro-Line II Filing Frame is the perfect solution in regards to the professional equipment of office cabinets. It combines innovative technology with
More informationVehicle and Container Fall Protection
156 01.8 Vehicle and Container Fall Protection 158 160 162 157 Web Rail by SpanSet is an effective solution to fall protection from the back of heavy vehicles. Featuring our patented Tension Force Indicator
More informationCompact Vacuum Systems
Compact Vacuum Systems 6 Compact Vacuum Systems DC 11-Module The DC 11-Module is a complete central unit for source extraction and industrial cleaning. The unit can manage just about every kind of dust
More informationEDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc
AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 Ceiling or wall mounting extract ventilation Extract ventilation through wall or using a shunt duct system All V models incorporate all accessories
More informationPE 100-RC ball valve THE MAINTENANCE-FREE HIGH-PERFORMANCE VALVE
PE 100-RC ball valve THE MAINTENANCE-FREE HIGH-PERFORMANCE VALVE EN The Plastics Experts. The AGRU isolation valve makes it possible to install continuous PE 100-RC pipelines without the extra effort of
More information1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...
1/11 29/06/2016 VENTILATION AND Buildings & Technical Services Section AIR-CONDITIONING STANDARD CONTENTS 1. GENERAL... 2 2. DUCTS, AIR VENTS, VALVES... 2 3. MONOBLOCK UNITS... 3 4. FILTRATION... 5 5.
More informationSound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3
, Sound attenuating louvres Rectangular sound attenuators DZ-2, DZ-3 Application are designed to attenuate noises of fans and air-conditioning devices in ventilation and air-conditioning installations.
More informationSchüco Premium Collectors Outstanding quality, performance and design
Schüco Premium Collectors Outstanding quality, performance and design 2 Schüco Premium collectors Schüco Premium line collectors - The next generation Since its entry into the solar thermal sector, Schüco
More informationRoof Upblast and Sidewall Exhaust
XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,
More information5/S1 KITCHEN HOODS NZK, NZR, NZP, NSK, NSR, NSP, NES, NEZ. v 2.6 (en)
5/S v. (en) NZ, NZR, NZP, NS, NSR, NSP, NES, NEZ www.klimaoprema.hr www.klimaoprema.hr 7 TAE CNTENTS Types and sizes... 9 Conventional wall s... Conventional ceiling s... Economic s... Accessories... Construction
More informationSEMI RIGID THE PROFESSIONALS CHOICE
SEMI RIGID THE PROFESSIONALS CHOICE for efficient, high performance MVHR ductwork installations. SAP APPENDIX Q LISTED brookvent.co.uk FITTING OUTLINE THE PROFESSIONALS CHOICE for efficient, high performance
More informationAIR TECH SYSTEMS. Installation Instructions. LTG Air Diffusers. Linear air diffusers LDB. Installation in ceilings, walls and sills
AIR TECH SYSTEMS Installation Instructions LTG Air Diffusers Linear air diffusers LDB Installation in ceilings, walls and sills LTG Comfort Air Technology Air-Water Systems Content Page Safety instructions
More informationFILIGREE TECHNOLOGY - HIGHLY DURABLE B E W E G U N G M I T S Y S T E M
G E Z E DOOR T E C H N O LO G Y AND GLASS SYSTEMS GEZE SLIDING FIT TING SYSTEMS FILIGREE TECHNOLOGY - HIGHLY DURABLE B E W E G U N G M I T S Y S T E M TABLE OF CONTENTS Introduction: Filigree technology
More informationAxial fans. What s more, non-stock models are normally available within two weeks.
Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive
More informationOperating instructions
Operating instructions Type TEKA filtoo TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72 E-Mail:
More informationAcoustic humidity sensitive air inlet. Technical specifications
Acoustic humidity sensitive air inlet Technical specifications Copyright Aereco. Data and pictures not contractual. Some characteristics may vary. Aereco S.A keeps the right to modify any characteristic
More informationLouvred Grilles can be used internally and externally are available with or without a flyscreen and provide excellent airflow performance.
Mech-Elec. Available with round spigots or rectangular sockets to fit all ducting systems Various types for different applications External and internal options Choices for the wall, ceiling and roof Manufactured
More informationStaging the fire without wasting energy
Staging the fire without wasting energy Thermal comfort > operates either as an open fire or as a glass-door stove > cheats in 2 different ways : direct radiation and natural convection > the partial opening
More informationFilterMax F. Modular dust collector with integrated pre-separator. Models
Technical leaflet 988010 10 1 Date 2009-11-02 FilterMax F Modular dust collector with integrated pre-separator FilterMax F is a complete filter solution for the entire workshop. With it s integrated preseparator
More informationClimate Recovery Duct System Technical Specifications
Climate Recovery Duct System Technical Specifications Climate Recovery (CR) Duct System Climate Recovery (CR) Duct System Overview The CR Duct System offers a complete, pre-insulated system for heating,
More informationHoods for professional kitchens
Hoods for professional kitchens smarter ventilation Our kitchen hoods have been developed to provide the best possible comfort in all types of professional kitchens. But we haven t just satisfied ourselves
More informationFANS WITH ENERGY EFFICIENT EC TECHNOLOGY
FANS WITH ENERGY EFFICIENT EC TECHNOLOGY ECOFIT ETRI THE AIR MOVEMENT GROUP Rosenberg Ventilatoren GmbH Maybachstr. 1/9 D-74653 Künzelsau-Gaisbach Fon +49 (0)7940 / 142-0 Fax +49 (0)7940 / 142-125 www.rosenberg-gmbh.com
More informationTABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..
585457 1 TABLE OF CONTENTS SECTION PAGE INTRODUCTION.. 3 INSTALLATION PROCEDURES Air Conditioner Location...4 Air Conditioner Mounting 4 A/C Ducting Installation...5 Power Kit Installation (Batteries)...5
More informationProduct & Description Order Code Dimensions (mm)
1RD 100 X 350MM Ø100 L 350 1RD 100 X 1M Ø100 L 1000 Rigid Ducting PVC 1RD 100 X 2M Ø100 L 2000 1.0 2.8 6.2 1RD 100 X 3M Ø100 L 3000 1RD 125 X 350MM Ø125 L 350 1RD 125 X 2M Ø125 L 2000 0.4 1.4 3.8 1RD 150
More informationAFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)
AFA TS GmbH - Werner von Siemens Str.3 - D-72661 Grafenberg Copyright 2009 Tel.: +49(0)7123-97382-0 - Fax: +49(0)7123-97382-90 - E-Mail: mail@afa-ts.de Page 1-15 www.afa-ts.com Exhaust Extraction Systems
More informationVRF. For Commercial and Light Commercial
118 VRF For Commercial and Light Commercial 119 SOLUTIONS SMALL OFFICES Fujitsu General provides perfect total air conditioning systems that take into account energy saving, low noise, comfortable airflow,
More informationDiesel Cooker X 100. Installation Instructions
Diesel Cooker X 100 Installation Instructions Index 1. Legal notices 2. Overview and function 3. Installation 4. Fuel supply 5. Electrical connections 6. Exhaust system 7. Initial start-up 8. Technical
More informationEnergy Efficient Pumpset & Pumpset Selection. Page 1
Energy Efficient Pumpset & Pumpset Selection Page 1 Pumpset : 5HP motor means it can deliver up to 5HP brake horse power output power. 5HP pump means it required a minimum of 5HP brake horse power input
More informationModel ND-2 Specification
Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction
More informationUTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management
Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and
More informationPRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions
PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean One system, many solutions SIMPLY COST EFFECTIVE AND UNIVERSALLY APPLICABLE The perfect solution for separation of dust, particulate matter
More informationAchieve Up To 200% Greater Efficiency And Better Air Flow Performance With GE ECM Technology
Achieve Up To 200% Greater Efficiency And Better Air Flow Performance With GE ECM Technology GE ECM 2.3 ECM X13 What's an ECM? The highest efficiency motor there is! essentially a DC Motor Without mechanical
More informationFilterMax DF. Modular dust multi purpose collector. Models
Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive
More informationFlue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer
834449_05GB_022005.qd 02.02.2005 17:12 Uhr Seite 1 For the installer Flue installation instructions Air flue duct for use with ecomax and ecotec boilers ecomax 613/2 E ecomax 618/2 E ecomax 622/2 E ecomax
More informationNEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance
March 29 Iris Control Damper (ICD) NEW Iris Control Damper (ICD) For adjustment and measuring of airflow Features Quick and simple installation and maintenance Extended spigot connections 1% opening capacity
More informationNETWORK AND SERVER CABINETS
NETWORK AND SERVER CABINETS Network and Server Cabinets Construction of the Network and Server Cabinet of the Unique Series The cabinets of the Unique Series are made out of 2 mm steel sheet metal and
More informationViking Installation Guide
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at
More informationZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS
ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive
More informationFilterMax DF. Modular dust multi purpose collector. Models
Technical leaflet 988009 10 1 Date 2009-10-26 FilterMax DF Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the
More informationIrisControlDamper. For Adjustment and Measuring of Airflow.
IrisControlDamper For Adjustment and Measuring of Airflow www.actionair.co.uk sales@actionair.co.uk Iris Control Damper (ICD) Quick, silent and efficient is the simple summary of the features of the Actionair
More information