5/S1 KITCHEN HOODS NZK, NZR, NZP, NSK, NSR, NSP, NES, NEZ. v 2.6 (en)
|
|
- Bethany Maud Gibbs
- 5 years ago
- Views:
Transcription
1 5/S v. (en) NZ, NZR, NZP, NS, NSR, NSP, NES, NEZ 7
2 TAE CNTENTS Types and sizes... 9 Conventional wall s... Conventional ceiling s... Economic s... Accessories... Construction Hood size Hood is made of stainless steel AISI, according to DIN 59. Unique construction enables all condensation, from inner surfaces and filter units, to be drained in one or more draining taps. Grease traps and fire resistant grease traps can be installed without construction changes. Air volume quantities are determened by VDI 5. Hood size is determened by size of kitchen appliances from which air should be extracted. or wall or ceiling with installation height h=,m, outer sides of should overhang ends of equipment by minimum of. If installation height is h>,m, angle between end of equipment and side should be achived (see picture below). or economical s, width should be increased by the width of inactive edge (wall version -, ceiling version - ). resh air supply... 9 d d d b a h Definition of symbols: [m] H [m] [m] d [m] b [m] h [m] x [m] - itchen width - itchen height - itchen - verlap - Appliance width - Installation height - Exhaust connection dimensions ExS [m] V [m/h] v [m/s] p [Pa] axbxc [m] - Exhaust connection dimensions (eco-s) - Airflow rate - Effective air velocity - Pressure drop - itchen dimensions 9
3 CNVENTINA WA HDS widths () rdering key: C , wall, inclined,, width height ; height H = NZ x x utter dimensions x x H ther sizes available on request Appropriate number of M filters is delivered with ire resistant filters PN or combined filters M NZ NZ zidna kosa Inclined wall NZR NZR zidna Horizontal wallravna NZP NZP zidna Rectangularpravokutna wall Room entering problems should be considered when ordering larger dimension. In such case, we can make multipart. (combination of PN and M) are delivered on request Material: Stainless steel sheet / / / / / < / = - / / / =- * displays suspension for model NZR / extract air volume Extract air connection x taps ilter units m/h x 5 ightning characteristics amp W x x x 7 x 7 x 7 5 x 57 5 x x x x 7 7 x 7 x 7 x 7 x 7 x 7 x 57 x 57 5 x 57 5 x 57 x 57 5 x 57 5 x x 57 7 x 57 7 x 57 Dimensions lamps suspensions M amp C
4 CNVENTINA CEIING HDS widths () rdering key: C , ceiling, inclined,, width height ; height H = NS NS Inclined ceilingkosa središnja NSR NSR Horizontal ceilingravna središnja / / / / < / = - / / / =- Room entering problems should be considered when ordering larger dimension. In such case, we can make multipart. NSP NSP Rectangular središnjaceiling pravokutna utter dimensions x x H ther sizes available on request Appropriate number of M filters is delivered with ire resistant filters PN or combined filters M (combination of PN and M) are delivered on request Material: Stainless steel sheet C NS x x / extract air volume Extract air connection x taps ilter units m/h ightning characteristics lamps amp W 5 x 5 x 5 x 5 x 7 5 x 7 5 x 7 5 x x x 57 5 x 57 5 x x x 7 5 x 7 5 x x x 57 5 x x 57 5 x 57 5 x x x x 7 5 x 57 5 x 57 Dimensions amp suspensions
5 ENERGY-SAVING HDS (EC-HDS) widths () Energy saving operates with approximately 7% of external unheated air, supplyed trough a special duct and fan, and delivered trough a jet profiled slot to extraction filters. High lateral velocity of a cold air jet induces a low pressure zone beneath the and enables efficient ehxaust of of vapours, smoke, grease particles and odours. Cold air jet lowers the filter temperature below grease condensation temperature ( C), thus fostering grease separation and condensation of vapours. External air ducts are heat insulated to prevent condensation. Energy saving s can easily satisfy minimal venti- lation requrements of 5 m/h per m according to VDI 5. The result of that is less grase in exhaust system, easy cleaning and mantainance, lower risk of fire and preservation of building roof or facade. However, in order to achieve full efficiency of this type, some % of exhaust air in the kitchen have to be restored by fresh air that needs to be heated to C in winter. rdering key: -, energy-saving, ceiling,, width and height ; height H = utter dimensions x x H ire resistant filters PN or combined filters M = - 5 Supply air air connection connection Supply EE x S connection Extract air connection x taps taps ilter filter units units m/h 9 x x 5 9 x x ightingcharacteristics characteristics ighting extract extract air air of of volume Dimensions Dimensions Dimensions Dimensions volume lamps suspen Connection sions suspensions M amp amp amp amp W x 5 x 5 x 7 x x 7 x 5 57 x x x x x x x x x x x x x x x x x x 5 57 x x 5 57 x x 5 57 x x 5 57 x x x x x x x x x x x x 5 57 E /- S 5 Room entering problems should be considered when ordering larger dimension. In such case, we can make multipart. (combination of PN and M) are delivered on request Material: Stainless steel sheet Energy saving ceiling (twosided), NES NES x x ther sizes available on request Appropriate number of M filters is delivered with 5
6 Energy saving ceiling (onesided), NEZ % widths () ilter 7% % Iz prostorije % 5 S E 5 = - 5 utter dimensions x x H ther sizes available on request Appropriate number of M filters is delivered with ire resistant filters PN or combined filters M (combination of PN and M) are delivered on request Material: Stainless steel sheet -, energy saving, wall,, width and height ; NEZ x x height H = tp = C rdering key: Grijač Supply air connection ExS taps filter units extract air volume m/h Room entering problems should be considered when ordering larger dimension. In such case, we can make multipart. Extract air connection x amp characteristics suspensions Connection 7 7 lamps amp amp W x x x x x x 9 x x Dimensions Dimensions 9 x x 7 x x 57 5 x x x x 57 x x 57 x x 57 7 x 9 x 7 7 x 9 x x 9 x 7 9 x 9 x 7 9 x x x x 57 x x 57 x x 57 5 x x 57 5 x x 57 x x 57 5 x 9 x x 9 x 57 5 x 9 x x x x x 57 7
7 ACCESSRIES Inox lamp Grease trap filter, type M Grease separation Grease separation [%] p re dro ressu P p [ Pa],,,, ilter casing made of aluminium sheet, filter insert made of expanded aluminium sheet ilter inserts can be easily removed from casing for cleaning Advantages: - High efficiency of grease separation (up to 9%) - Relatively small air pressure drop Recoended air velocity at filter inlet: v=. m/s. Typical filter surface treatment: anodised in natural colour of Al Power [W] V Hz IP 5 5 ight source T G T G fluorescent, watertight inox lamp casing made of stainless steel sheet difusor made of tempered glass all electric parts are placed on white metal board with aluminium shade Dimensions a x b x c [] 5x75x9 5x5x9 c T G 5x5x9 a, v[m/s] Suspension elements ire resistant grease trap filter, type PN Grease separation [%] Grease separation re essu Pr,,, drop, p [ Pa] b, v[m/s] ne suspension set consists of: - tensioner - hooks ( pcs) - concrete anchor Ø - chain m This type of grease filter is designed for kitchens where increased inflaability hazard exists Made of aluminium sheet. Smooth surfaces enable easy cleaning. Can be washed in a dishwasher. Sharp airstream bends between the blades prevent penetration of flames (that may occur on the working surface) to the exhaust Advantages: - High efficiency of grease separation (up to 9%) - Relatively small air pressure drop Recoended air velocity at filter inlet, v =..5 m/s. Inlet velocity higher than.5 m/s causes higher level of exhaust duct noise resh air supply (NES) Combined grease filter, type M Grease separation [%] Grease separation rop d sure Pres,,, p [ Pa],, v[m/s] Ø Advantages: - High efficiency of grease separation (more than 9%) - Prevention of flame penetration into the exhaust duct system - Easy cleaning and maintainance - Washing in a dishwasher Grease separation efficiency of energy-saving exhaust s is higher than of conventional s The main reason lies with intensive cooling of filters, causing higher condensation rate of moisture and grease droplets. These are also main parameters for assessing quality of exhaust air filtering in hotel and restaurant kitchens Recoended air velocity through the combined M filter is v =. -.5 m/s. Velocity higher than.5 m/s causes higher level of exhaust duct noise / resh air supply Distance Dimensions pcs - / Ø - / Ø - / Ø - / Ø - / Ø /,5 5 5 filter dimensions x x x resh air supply (NEZ) x resh air supply connection Distance Dimensions pcs - / Ø 9
8 ,5 5 5 ACCESSRIES NTES: resh air supply (NEZ) Ø / resh air supply connection Distance Dimensions pcs - / Ø - / Ø - / Ø - / Ø - / Ø ilter 7% / % % ow diffuser velocity rom room % 5
J L I e x h a u s t h o o d
JLI exhaust hood PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air 7 Pressure loss & Sound data, Lights 8 We want
More informationSlot diffusers, Round duct diffusers. IMP Klima
, Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING
More informationKVI Kitchen Canopy With Capture Air
KVI Kitchen Canopy With Capture Air SCHLIEREN THERMAL IMAGING SYSTEM Capture Jet on Capture Jet off SAME EXHAUST RATES, DIFFERENT RESULTS The KVI is a highly efficient kitchen ventilation canopy that removes
More informationKWF Water Wash Canopy with Supply Air
KWF Water Wash Canopy with Supply Air SCHLIEREN THERMAL IMAGING SYSTEM Photographer: Matti Lehto The KWF is a highly effective kitchen ventilation canopy for the removal of contaminated air and excess
More informationSLOT DIFFUSERS, ROUND DUCT DIFFUSERS
SLOT DIFFUSERS, ROUND DUCT DIFFUSERS Slot diffusers LD-3, LD-4, LD-5 LD-3 LD-4 LD-5 SLOT DIFFUSERS Application: Slot diffusers are designed for air supply in rooms with floor to ceiling heights of 2.5
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades
More informationHoods for professional kitchens
Hoods for professional kitchens smarter ventilation Our kitchen hoods have been developed to provide the best possible comfort in all types of professional kitchens. But we haven t just satisfied ourselves
More informationFilter Hood Model CA-S
Model CA-S Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety,
More informationCeiling diffuser 4DE
Ceiling diffuser 4DE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...
More informationWhen Time Matters! listed Fire Damper
listed Fire Damper The FAST fire damper is offered as an option for containing fire and smoke under the hood in the event of a fire from a cooking appliance. Construction : The fire damper is assembled
More informationCeiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades
X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling
More informationKWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology
KWT GALLEY WATER WASH HOOD With supply air and Capture Jet technology APPLICATIONS Halton KWT is a galley water wash hood for use in marine & offshore applications. The highly efficient KWT hood uses Halton
More informationUTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management
Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and
More informationMaximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment
Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...
More information7/S5 FIRE DAMPER FD40. v 2.9 (en)
7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire
More informationHoods for professional kitchens
Hoods for professional kitchens smarter ventilation Our kitchen hoods have been developed to provide the best possible comfort in all types of professional kitchens. But we haven t just satisfied ourselves
More informationGigaBox centrifugal fans Product specific information
GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,
More informationNovenco Tunnel Fans. Novax October 2007
Novenco Tunnel Fans Novax October 2007 Product facts Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC and AUR) and
More informationModel ND-2 Specification
Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationceiling swirl diffuser DQJ
ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...
More informationCeiling Slot Diffuser Model DSX
Ceiling Slot Diffuser Model DSX Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationMultifunctional 400ºC/2h and 300ºC/2h roof fans
HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544
More informationSwirl Diffuser Model DQF
Swirl Diffuser Model DQF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationFilterMax DF. Modular dust multi purpose collector. Models
Technical leaflet 988009 10 1 Date 2009-10-26 FilterMax DF Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser
More informationCVHT Series - F rated cabinet fans
N 50-55 1/1/08 19:26 Página 50 BLT DRIVN BINT NS Series - 00 120 rated cabinet fans NW pproved to N12101- standard Range of belt drive cabinet fans designed for smoke extraction in fire conditions and
More information7/S6 FIRE DAMPER FDC40. v 2.9 (en)
7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with
More informationInstructions for use and installation Cooker Hood
Instructions for use and installation Cooker Hood FTU 3807 WXS 70H FTU 3807-P WXS 70H Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS...18 CHARACTERISTICS...19 INSTALLATION...20 USE...24 MAINTENANCE...25
More informationFilterMax F. Modular dust collector with integrated pre-separator. Models
Technical leaflet 988010 10 1 Date 2009-11-02 FilterMax F Modular dust collector with integrated pre-separator FilterMax F is a complete filter solution for the entire workshop. With it s integrated preseparator
More informationCeiling diffuser 4DF
Ceiling diffuser 4DF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contens Description...3 Construction...
More informationTubular Centrifugal Fans
Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,
More informationDFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser
Halton DFB Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation flush to the ceiling, light-weight aluminium design Circular duct connection with rubber gasket All sizes
More informationSlot diffusers for ceiling installation
X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger
More informationCeiling Swirl Diffuser DQJ
Ceiling Swirl Diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de contents Description...3 Advantages...
More informationFresh air and exhaust air systems
Fresh air and exhaust air systems Fresh air and exhaust air systems Overview RECTANGULAR ROOF COWLS 1 2 3 4 5 6 7 Special versions on request 1 Jet cap DFH-E-Eco 5 Fresh air cowl ALH 2 Roof cowl DH 6 Discharge
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationFilterMax DF. Modular dust multi purpose collector. Models
Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive
More informationEDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM
AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation
More informationAnti-Pollution Ecological System
The FST ecological system was designed to meet all types of commercial kitchen installations. The ecological system is an environmentally-friendly solution that helps maintain air quality. The main objective
More informationseries KFD-KLD Linear slot diffusers
series KFD-KLD Linear slot diffusers www.koolair.com KFD-KLD Contents Linear slot diffusers KFD Selection tables KFD Dimensions 6 Connection system Linear slot diffusers KLD 8 Selection tables KLD 0 Dimensions
More informationBall-bearing KUA. A superflexible extractor for small and medium sized work places
Ball-bearing KUA A superflexible extractor for small and medium sized work places Copyright. All rights reserved. PLYMOVENT AB Föreningsgatan 37, SE-211 52 Malmö, Sweden Tel: +46 40 30 31 30, Fax: +46
More informationKH E, KH E
INSTRUCTIONS FOR USE Kitchen extractor hood Type: KH 17101 E, KH 17106 E Dear Customer!! You are now a user of the newest generation kitchen extractor hood of KH 17101, KH 17106. This hood has been designed
More informationRound duct diffuser DBB-RR
Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More information2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m
2/18/EN/2 Air Handling Lights Type LR Recommended for use in rooms with ceiling heights of approx. 2.60... 4.00 m Contents Description Description... 2 Supply Air Construction LR-Z... 3 Extract Air Construction
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation
More informationCleanroom Filtration
Cleanroom Filtration Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the absolute filter
More informationAFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)
AFA TS GmbH - Werner von Siemens Str.3 - D-72661 Grafenberg Copyright 2009 Tel.: +49(0)7123-97382-0 - Fax: +49(0)7123-97382-90 - E-Mail: mail@afa-ts.de Page 1-15 www.afa-ts.com Exhaust Extraction Systems
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationParticle Filter Box FKU
Particle Filter Box FKU Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationMixed Flow Roof Fans (RMH)
Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationKVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood
Capture Jet Hybrid Backshelf Hood The hybrid backshelf model of Capture Jet hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment,
More informationCOLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air
Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed
More informationSEMI RIGID THE PROFESSIONALS CHOICE
SEMI RIGID THE PROFESSIONALS CHOICE for efficient, high performance MVHR ductwork installations. SAP APPENDIX Q LISTED brookvent.co.uk FITTING OUTLINE THE PROFESSIONALS CHOICE for efficient, high performance
More informationDuct Nozzle Diffuser. L e
Duct Nozzle Diffuser L-08-1-08e Contents Application Construction Safety instructions Contents Application Construction Safety instructions 2 Dimensions 3 Quick selection for ducts with 1 to 3 rows of
More informationMAJAX-2 GENERAL SPECIFICATION
MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed
More informationWGA Long throw nozzle grille
Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...
More informationType DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES
Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION
More informationCatalog Swirl diffuser DAL 358
Catalog 1.1.1 Swirl diffuser DAL 358 Concordia University, Montréal, Canada DAL 358 model DAL 358 1 DAL 358 2 Method of operation............................................ DAL 358 3 Flow and direction
More informationKVL-P with Plate Shelf
The model of Capture Jet TM hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment, helping to provide a comfortable and clean environment.
More informationFALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable
More informationNR series. Circular CAV air volume control terminals with system powered mechanical regulator
series Circular CAV air volume control terminals Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5
More informationType VSD35. Nominal length up to 1500 mm: one spigot
Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements
More informationKrantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems
Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems DS 10 E 01.018 Preliminary remarks Where workplaces or production facilities have to be kept
More information1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8
These technical specifications state a row of manufactured sizes and versions of whirling air outflow outlets VVDM 300, 400, 500, 600, 625 und 825 (further only outlets). It is valid for production, designing,
More informationUse. Installation. Key figures. Worth noting. linx industries chilled beams
89 Use Lindab's supply air beam can be used for cooling, heating and ventilation. Installation I-60 is installed into a false ceiling, and can be suspended by hangers or threaded rods. As standard is delivered
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationJSI/JLI TURBO HOODS. Installation, adjustment and user guide
JSI/JLI TURBO HOODS Installation, adjustment and user guide JSI-Turbo Installation-, adjustment and user guide WWW.JEVEN.FI PAGE Table of Contents Installation of hanging brackets Fixture points and connecting
More informationNORDcanopy. Installation, use and maintenance manual
NORDcanopy Installation, use and maintenance manual Installation, use and maintenance manual The choice of kitchen extractor hoods depends on the size of the kitchen equipment. The hood must be 00-00 mm
More informationDVAX-ARS. Roof-mounted unit for mechanical smoke extract
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit
More informationProduct manual Extraction arm KUA
Product manual Extraction arm KUA Table of contents: Page: Technical description...2 Delivery...2 Area of use...2 Technical data...2 Components and operation...2 Working radius...3 Pressure loss...3 Mounting
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air
More information1 AIR HANDLING UNIT TYPE AIR ACCESS 75
SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting
More informationAIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS
AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS Airodyne multi leaf volume control tampers have been specifically designed for use in air conditioning and ventilation system for volume,
More informationPURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS
Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with
More informationWALL VENTILATION GRILLES CBP
WALL VENTILATION GRILLES CBP 01.10-01 CBP WALL VENTILATION GRILLES Description Designed for ventilation and air-conditioning installations, where control of air flow and direction of the air is required.
More informationInduction terminal units
series IHK Series IHK 1 Induction terminal units IHK IHK-F IHK-V CONTENTS age eneral Features 2 Dimensions and Configurations 4 Induction terminal unit IHK-F 5 Induction terminal unit IHK-V 6 Installation
More informationKVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets
KVR Capture Jet Round Island Hood with Perimeter Jets The KVR Round Island Capture Jet hood with perimeter jets is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat
More informationInline Fans [ 14 ] * UL is optional and must be specified.
XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC
More informationtechnical catalogue Revision 30/4/13 1
technical catalogue Revision 30/4/13 1 Index FLEXIBLE DUCT Page No. Metalised flexible duct 4 Metalised acoustic flexible duct 5 Flexible duct pressure drop table 6 PLASTIC GRILLES AND DIFFUSERS Plastic
More informationAKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599
EN 599-604 AKOR-HR 14/1/08 13:01 Página 599 HIGH EFFICIENCY HEAT RECOVERY UNIT AKOR-HR NEW Heat Recovery unit with casing manufactured from expanded polypropylene. Outlet and inlet duct conectors Ø150.
More informationParticle Filter Box Model FKF
Particle Filter Box Model FKF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling
ROOF MOUNTED FNS Series Mixed Flow Fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements Range of roof mounted mixed flow fans supplied as standard for
More informationCarisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet
Carisma CRC Fan Coil Unit with Centrifugal Fan with synchronous Motor Range includes 9 air rates (from to 1500 m /h) and 5 models (for wall and ceiling installation, with casing and concealed), each equipped
More informationCleanroom Filtration
Cleanroom Filtration Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the absolute filter
More informationROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling
MIXVENT-TH ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured from high strength
More informationFan coil unit NBS 100/150
Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationMixed Flow Roof Fans (RMH)
Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company
More informationActive Chilled Beams
T 2.4/3/EN/1 Active Chilled Beams Type DID00B TROX GmbH Telephone +49/2 45/2 02-0 Telefax +49/2 45/202-25 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com Contents Description
More informationCompact Grille Model KG
Compact grille KG Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...3
More information10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage
Submersible drainage pumps US 6-5 0 mm free passage Application The submersible drainage pumps US 6-5 can be used wherever sewage water with solids up to 0 mm particle size occurs, e.g. in collection sumps
More informationHomepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM
Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL
More informationUSER S MANUAL. TwinFresh R-50 SINGLE-ROOM REVERSIBLE VENTILATOR
USER S MANUAL SINGLE-ROOM REVERSIBLE VENTILATOR 2 CONTENT Introduction Use Delivery set Designation key Main technical parameters Safety requirements Design and operating logic Mounting and set-up Unit
More informationWORKPLACE lights. Light range JAPL Light range JAPO Light range JAPH
02 2016 WORKPACE lights ight range JAP ight range JAPO ight range JAPH WORKPACE IGHTS JAP+JAPO+JAPH JUNG workplace lights are sheet steel lights for use at the workplace in industry and the manual trades.
More informationDiffusion grilles for installation in ducts
L-02-1-09e Diffusion grilles for installation in ducts Type / Content Application Safety instructions Content Application Safety instructions 2 Realisation 3 Dimensions Installation Dimensioning 4 Quick
More informationVersatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits
Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable
More information