VRF. For Commercial and Light Commercial
|
|
- Branden Garrison
- 6 years ago
- Views:
Transcription
1 118 VRF For Commercial and Light Commercial
2 119
3 SOLUTIONS SMALL OFFICES Fujitsu General provides perfect total air conditioning systems that take into account energy saving, low noise, comfortable airflow, small room application and Centralised control for small-sized office buildings with many small rooms. Energy saving solution suitable for meeting rooms and business discussion rooms When there are no people in the room, save operation starts automatically to prevent unnecessary power consumption by linking up with a human sensor and external input/output kit. Compact and low noise design outdoor unit NEW This compact outdoor unit doesn t take up much space even if installed in a plant room or on the rooftop. This unit secures enough static pressure even if there are louvres. Low noise operation is possible at nighttime by a low noise mode. Up to 12 HP by compact outdoor unit Small VRF System Small VRF system is suitable for buildings with many small rooms. Max. 30 indoor units can be connected. 120
4 Comfortable office air conditioning without draughts Circular Airflow Cassette blows out in all directions without temperature unevenness Individual airflow direction control to prevent occupants being exposed to draughts Energy saving operation when there are no people in the space linking up with the human sensor Human sensor (option) 1.1 kw personal air conditioning Centralised control of both air conditioning and lighting Various range of low capacity 1.1 kw indoor units to suit small rooms or spaces. It is possible to perform centralised control to stop the operation of lighting and ventilation equipment in addition to air conditioners. This is useful for energy saving management over the whole building. System Controller Lite VRF indoor units Facilities Lightning Ventilation Energy Recovery Ventilator 121
5 SOLUTIONS SHOPS,RESTAURANTS & COMPLEX BUILDINGS Fujitsu General provides efficient air conditioning systems to tenants and customers in shops and restaurants. Small VRF system NEW Large Duct Appropriate air conditioning in the atrium space Appropriate air conditioning of the high ceiling and glasssided atrium space with a large ducted system J-II & J-III for RESTAURANTS J-II & J-III Outdoor units For restaurants, offices etc. 122
6 NEW LAN or Wireless LAN Centralised control of air conditioning for all tenants Centralised control with simple touch panel operation of scheduled operation by tenant, centralised control and electricity charge apportionment Tablet PC Remote monitoring of air conditioning SMALL VRF for COMPLEX BUILDINGS J-IIS J-II & J-III J-IIIL SMALL VRF for SHOPS NEW possible with low outside air temperature J-IIIL Space saving installation Low outside air temperature cooling operation is necessary in winter in stores with a lot of heat inside. Air conditioning system can be supported flexibly to allow cooling operation at -15 C J-IIIL type outdoor units can connect up to 30 indoor units (refer to outdoor units for more details). This large capacity model makes large spaces comfortable. Furthermore, this is the top class compact outdoor unit in the industry Pa Medium Static Pressure Ducted 123
7 SOLUTIONS LARGE BUILDING Fujitsu General provides modular type VRF systems that achieve high efficiency, comfort, design freedom, easy installation and reliability for skyscraper buildings. Individual air conditioning system for large buildings Capacities in simultaneous cooling and heating is possible up to a maximum 48HP. Smart and cutting edge design. Extensive lineup from 8 HP to 48 HP in 2 HP increment. Connectable indoor unit capacity ratio up to 150% 8 HP - 48 HP 34 Models Space saving combination: 8 HP to 48 HP/21 models Energy efficiency combination: 16 HP to 44 HP/13 models Abundant lineup suitable to match the operating environment VRF series lineup to meet various needs such as energy saving models and models compatible with a high outdoor air temperature of 52 C Heat Pump Modular type for heating or cooling operation 8 HP - 54 HP 39 Models Space saving combination: 8 HP to 54 HP/ 24 models Energy efficiency combination: 16 HP to 46 HP/ 15 models 124
8 Enhancement of functions and basic performance to increase reliability Longer life expectancy is achieved by controlling excessive load on one unit through rotation operation and refrigerant distribution control. Rotation DC AC DC AC DC 3 DC 1 AC 4 2 AC 5 DC 3 Rotation DC 1 AC 4 DC 2 AC 5 DC 3 Rotation Link up with a variety of BMS Centralised control including facilities and equipment in addition to air conditioning is possible by linking up with MODBUS, BACnet, KNX and other MODBUS interfaces. System Controller (UTY-APGXZ1) System Controller Lite (UTY-ALGXZ1 & UTY-PLGXX2) system flexibility Flexible installation on each floor and installation of diverse indoor units is possible through the industry s top class high static pressure, long piping design and connection capacity. V-III series 82 Pa * Installation Example Rapid service support The air conditioning of the entire building can be monitored remotely with Web Monitoring Tool and System Controller. Rapid response to emergencies is possible by self-diagnosis enabling alert to a maintenance company. Internet or Public Telephone Line Remote Monitoring Web Monitoring Tool UTY-AMGXZ1 Software *: For V-III series. VR-II series & V-II series are 80 Pa 125
9 126 SMALL VRF
10 PRODUCT LINE UP SMALL VRF Outdoor Units Capacity (kw) HP J-IIS Series Page 128 AJY040LCLAH AJY045LCLAH AJY054LCLAH J-II Series Page 132 AJYA40LALH AJYA45LALH AJYA54LALH NEW J-III Series Page 136 AJY040LBLAH AJY040LELAH AJY045LBLAH AJY045LELAH AJY054LBLAH AJY054LELAH NEW J-IIIL Series Page 140 AJY072LELAH AJY090LELAH AJY108LELAH SMALL VRF 127 PRODUCT LINEUP SMALL VRF Outdoor Units 128 AIRSTAGE J-IIS 132 AIRSTAGE J-II 136 AIRSTAGE J-III 140 AIRSTAGE J-IIIL 162 PRODUCT LINEUP VRF Indoor Units 164 Indoor Units for VRF Specifications 127
11 SMALL VRF Heat Pump for Small Capacity Type Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. System Outline Space saving and low sound level design Economical individual air conditioning is achieved by ALL- DC technology, large capacity DC twin rotary compressor, and 3-row heat exchanger in a compact size. Flexible systems for homes, shops, small-size buildings air conditioning Due to compact size design and flexible piping design, J-IIS series can be installed easily in places where the installation space is limited such as homes, shops, and small offices. Multiple indoor units of various capacities and types can be connected. 128
12 Small and light weight outdoor unit This model is much more compact than conventional 6 HP comparable outdoor units. Even when installed on the balcony it fits within the height of the fence. The compact size with a height of less than 1 m allows it to be installed under windows and in tight spaces Current model / 6 HP class Height:1334 mm Weight:117 kg Model / 6 HP class Height difference 998 mm 25% It Can be Easily Carried and Installed in restricted Places Light weight 87 kg 26% Advanced high efficiency technology Large propeller fan performance and low noise achieved by large propeller and optimisation of angle. DC inverter control Efficiency is improved by mounting of new active filter module. Low noise rubber DC fan motor Miniaturised, low noise, high efficiency, multi-stage DC fan motor is mounted. efficiency compressor motor Optimised refrigerant flow design ly accurate parts Large heat exchanger Heat exchange performance is substantially improved by mounting of 3-row large heat exchanger. Compact and high performance DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. heat transfer copper tube (Improved lead angle) Smooth airflow grille This grille was aerodynamically designed for good efficiency with little blow loss. Compressor efficiency Compressor capacity 100% 129
13 SMALL VRF Features Long piping length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 80 m. This opens up new possibilities in system design. Actual piping length Max. 50 m Total pipe length Max. 80 m Height difference between outdoor and indoor units Max. 30 m Piping length from first separation tube to the farthest indoor unit Max. 40 m Height difference between indoor and indoor units Max. 15 m Non-stop oil recovery operation A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model J-IIS series (Heating operation) Operation stopped at oil recovery Non-stop oil recovery operation ON OFF ON Time Time Easier Installation Connection check function : Possible to confirm whether wiring connection and address setting are correct by a quick check run function. Display connected indoor unit numbers Duplicated indoor unit adresses can be displayed 130
14 4,5,6HP : AJY040LCLAH / AJY045LCLAH / AJY054LCLAH Specifications Rating Capacity range HP Model name AJY040LCLAH AJY045LCLAH AJY054LCLAH Maximum Connectable Indoor Unit Power source Single-phase, ~230V, 50Hz Capacity kw Heating Input power kw Heating EER W/W COP Heating W/W m 3 /h 4,040 4,200 4,200 Sound pressure level / Power level 51 / / / 70 db(a) Heating 54 / / / 70 Minimum Recommended MCB AMP Height Net Dimensions Width mm Depth Weight kg Refrigerant Type R410A R410A R410A Charge kg Connection pipe Liquid 3/8 3/8 3/8 Inch diameter Gas 5/8 5/8 5/8 Total pipe length m Max. height difference Operation range -5 to 46-5 to 46-5 to 46 C Heating -20 to to to 21 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function may work when using it outside the operation range. Dimensions (Unit : mm) Top view Front view Side view Rear view Bottom view Detail A 131
15 SMALL VRF Heat Pump for Small Capacity Type Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. System Outline Energy Efficiency Heat pump inverter control is used to achieve an efficient cooling and heating operation in any indoor unit combination. Flexible systems for small and medium size buildings air conditioning Space saving and long piping design allow for flexible installation on roofs or balconies of small and medium-size buildings. Multiple indoor units of various capacities and types can be connected. 132
16 Efficiency in actual operation Top class high COP is achieved for all models by large heat exchanger, high efficient DC twin compressor, and our own technologies. EER / COP [Single phase] Part Load Performance (6HP class) 66% up 46% up HP 5 HP 6 HP COP : EER : COP part load Heating part load EER Advanced high efficiency technology Large propeller fan performance and low noise achieved by large propeller and optimisation of angle. DC inverter control Efficiency is improved by mounting of new active filter module. DC fan motor Miniaturised, low noise, high efficiency, multi-stage DC fan motor is mounted. efficiency compressor motor Optimised refrigerant flow design ly accurate parts Subcool heat exchanger performance is improved by mounting of dual tube heat exchanger. DC twin rotary compressor Efficiency in all Countries and locations is good. Especially good performance from low to medium at normal operation. Pressure effect performance improved Enthalpy Large heat exchanger Heat exchange performance is substantially improved by mounting of 3-row large heat exchanger. Compressor efficiency DC Twin Rotary compressor Compressor capacity 133
17 SMALL VRF Features Long Piping Length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design. Total pipe length Max. 180 m Actual piping length 120 m max. Height difference between outdoor and indoor units 50 m max. For the outdoor unit installed below the indoor units: 40 m max. Piping length from first separation tube to the furthest indoor unit 40 m max. Height difference between indoor and indoor units 15m max. Non-stop oil recovery operation A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model J-III series (Heating operation) ON OFF Operation stopped at oil recovery Time ON Non-stop oil recovery operation Time Easier Installation Connection check function : Possible to confirm whether wiring connection and address setting are correct by a quick check run function. Display connected indoor unit numbers Duplicated indoor unit adresses can be displayed 134
18 4,5,6HP : AJYA40LALH / AJYA45LALH / AJYA54LALH Specifications Rating Capacity range HP Model name AJYA40LALH AJYA45LALH AJYA54LALH Maximum Connectable Indoor Unit Power source Single-phase, ~230V, 50Hz Capacity kw Heating Input power kw Heating EER W/W COP Heating W/W m 3 /h 6,200 6,400 6,900 Sound pressure level / Power level 50 / / / 69 db(a) Heating 52 / / / 69 Minimum Recommended MCB AMP Height 1,334 1,334 1,334 Net Dimensions Width mm Depth Weight kg Refrigerant Type R410A R410A R410A Charge kg Connection pipe Liquid 3/8 3/8 3/8 Inch diameter Gas 5/8 5/8 5/8 Total pipe length m Max. height difference Operation range -5 to 46-5 to 46-5 to 46 C Heating -20 to to to 21 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function may work when using it outside the operation range. Dimensions (Unit : mm) Terminal blocks (Transmission) Terminal blocks (Power) 3-Way valve (Liquid) Way valve (Gas) Ø28 (Cable port) Pipe port Ø28 (Cable port) Ø28 (Cable port) Pipe port Ø28 (Cable port) Ø28 (Cable port) Pipe port (Liquid valve) 297 (Gas valve) (Liquid) 51(Gas) (410) 40 Ø28 (Cable port) A Pipe & cable port 135
19 SMALL VRF NEW Heat Pump for Small Capacity Type Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. System Outline Energy Efficiency Heat pump inverter control is used to achieve an efficient cooling and heating operation in any indoor unit combination. Flexible systems for small and medium size buildings air conditioning Space saving and long piping design allow for flexible installation on roofs or balconies of small and medium-size buildings. Multiple indoor units of various capacities and types can be connected. 136
20 NEW Efficiency in actual operation Top class high COP is achieved for all models by a large heat exchanger, high efficient DC twin compressor, and our own technologies. EER / COP [3-phase] [Single phase] HP class 8% up % up HP 5 HP 6 HP : EER : COP 4 HP 5 HP 6 HP J-II J-III J-II J-III EER COP Advanced high efficiency technology Large propeller fan performance and low noise achieved by large propeller and optimisation of angle. DC inverter control Efficiency is improved by mounting of new active filter module. DC fan motor Miniaturised, low noise, high efficiency, multi-stage DC fan motor is mounted. efficiency compressor motor Optimised refrigerant flow design ly accurate parts Subcool heat exchanger performance is improved by mounting of dual tube heat exchanger. DC twin rotary compressor Efficiency in all Countries and locations is good. Especially good performance from low to medium at normal operation. Pressure effect performance improved Enthalpy Large heat exchanger Heat exchange performance is substantially improved by mounting of 3-row large heat exchanger. Compressor efficiency DC Twin Rotary compressor Compressor capacity 137
21 SMALL VRF NEW Features Long Piping Length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design. Total pipe length Max. 180 m Actual piping length 120 m max. Height difference between outdoor and indoor units 50 m max. For the outdoor unit installed below the indoor units: 40 m max. Piping length from first separation tube to the furthest indoor unit 40 m max. Height difference between indoor and indoor units 15m max. Non-stop oil recovery operation A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model J-III series (Heating operation) ON OFF Operation stopped at oil recovery Time ON Non-stop oil recovery operation Time Easier Installation Connection check function : Possible to confirm whether wiring connection and address setting are correct by a quick check run function. Display connected indoor unit numbers Duplicated indoor unit adresses can be displayed 138
22 4,5,6HP : AJY040LBLAH / AJY045LBLAH / AJY054LBLAH AJY040LELAH [3phase] / AJY045LELAH [3phase] / AJY054LELAH [3phase] NEW Specifications Rating Capacity range HP Model name AJY040LBLAH AJY045LBLAH AJY054LBLAH AJY040LELAH AJY045LELAH AJY054LELAH Maximum Connectable Indoor Unit Power source Single-phase, ~230V, 50Hz 3-phase, ~400V, 50Hz Capacity kw Heating Input power kw Heating EER W/W COP Heating W/W m 3 /h 6,200 6,400 6,900 6,200 6,400 6,900 Sound pressure level / 50 / / / / / / 69 db(a) Power level Heating 52 / / / / / / 71 Minimum Recommended MCB AMP Height 1,334 1,334 1,334 1,334 1,334 1,334 Net Dimensions Width mm Depth Weight kg Refrigerant Type R410A R410A R410A R410A R410A R410A Charge kg Connection pipe Liquid 3/8 3/8 3/8 3/8 3/8 3/8 Inch diameter Gas 5/8 5/8 3/4 5/8 5/8 3/4 Total pipe length m Max. height difference 50/40 (Outdoor unit: er/lower) 50/40 (Outdoor unit: er/lower) Operation range -5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46 C Heating -20 to to to to to to 21 Note: Specifications are based on the following conditions. : Indoor temperature of 27 CDB/19 CWB, and outdoor temperature of 35 CDB/24 CWB. Heating: Indoor temperature of 20 CDB/(15 CWB), and outdoor temperature of 7 CDB/6 CWB. Pipe length: 7.5 m; Height difference between outdoor unit and indoor unit: 0 m. The protective function may work when using it outside the operation range. Dimensions (Unit : mm) Terminal blocks (Transmission) Terminal blocks (Power) 3-Way valve (Liquid) Way valve (Gas) Ø28 (Cable port) Pipe port Ø28 (Cable port) Ø28 (Cable port) Pipe port Ø28 (Cable port) Ø28 (Cable port) Pipe port (Liquid valve) 297 (Gas valve) (Liquid) 51(Gas) (410) 40 Ø28 (Cable port) A Pipe & cable port 139
23 SMALL VRF NEW Heat Pump for Small Capacity Type Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. System Outline Compact Outdoor unit The compact and low sound level enable the units to be installed in various locations with restrictions or limited spaces such as plant rooms or rooftops. Small room application Up to 30 indoor units can be connected Available to be installed in various small rooms. Quiet design Top class low sound operation has been achieved. This allows installation of the units in locations without any special sound attenuation work. 140
24 Compact Design This model is much more compact than the conventional 12HP comparable outdoor unit. Discreet installation is possible even on the roof. Model / 12 HP class Height difference 1,428 mm 26% Space area 0.71 m 2 27% Current model J-IIIL Advanced high efficiency technology 570mm Large propeller fan The high efficiency and the low sound operation are mutually realized by reduction of a draught loss which are enabled by the Fujitsu General's original blade design and a large diameter propeller fan. DC inverter control Efficiency is improved by the new active filter module. DC fan motor Miniaturised, low noise, high efficiency, multi-stage DC fan motor is mounted. Subcool heat exchanger performance is improved by mounting of dual tube heat exchanger. Pressure effect performance improved Enthalpy Large heat exchanger Heat exchange performance is substantially improved by mounting of 2-row large heat exchanger rps Scroll compressor The scroll compressor has a wide range of rotational frequency from 15 to 120 rps together with Fujitsu General's unique sensorless sine wave control method which smoothly control the input power operation. The motor achieves an improvement on the energy efficient operation and the low sound operation. 141
25 SMALL VRF Features Long Piping Length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design. Actual piping length Total pipe length Max. 400 m Height difference between outdoor and indoor units 120 m max. 50 m max. For the outdoor unit installed below the indoor units: 40 m max. Up to 30 units can be connected The combination of the smallest but adequate capacity indoor unit and a new outdoor unit with the optimum efficiency heat exchanger achieves the industry s top class connection of 30 units. The total pipe length has been extended up to 400 meters to fulfill various room layouts. Piping length from first separation tube to the furthest indoor unit 60 m max. Height difference between indoor and indoor units * 50 m max. *: Only when new indoor units and J-IIIL series are combined Static Pressure External static pressure is available up to 30 Pa. (only 12HP) 30Pa Top Class Low Operating Sound Top class low operating sound is realised. ly suited to densely populated areas thanks to their low operating sound. Sound Power Level 66 db(a) 11 db(a) 77 db(a) J-IIIL (8 HP) Current model (8HP) 142
26 NEW 8,10,12HP: AJY072LELAH / AJY090LELAH / AJY108LELAH Specifications Rating Capacity range HP Model name AJY072LELAH AJY090LELAH AJY108LELAH Maximum Connectable Indoor Unit Power source 3 phase, ~400V, 50Hz Capacity Nominal Heating kw Max Heating Input power Nominal Heating kw Max Heating EER COP Nominal Heating W/W Max Heating m 3 /h 8,400 9,000 11,000 Sound pressure level / 52 / / / 73 db(a) Power level Heating 54 / 57 / 61 / Height 1,428 1,428 1,428 Net Dimensions Width mm 1,080 1,080 1,080 Depth Weight kg Refrigerant Type R410A R410A R410A Charge kg Connection pipe Liquid 3/8 3/8 3/8 mm diameter Gas 3/4 7/8 1 1/8 Total pipe length m Max. height difference 50 / 40 (Outdoor unit: Upper / Lower) Operation range -15 to to to 46 C Heating -20 to to to 21 Note: Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating: Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length: 7.5 m; Height difference between outdoor unit and indoor unit: 0 m. Dimensions (Unit : mm)
27 144 LARGE VRF
28 LARGE VRF 146 PRODUCT LINE UP LARGE VRF Outdoor Units 150 AIRSTAGE VR-II HEAT RECOVERY 156 AIRSTAGE V-III HEAT PUMP 160 PRODUCT LINE UP LARGE VRF Indoor Units 164 Indoor Units for LARGE VRF Specifications 145
29 PRODUCT LINEUP LARGE VRF Outdoor Units Capacity (kw) HP Space Saving Page 158~ VR-II Series Heat Recovery Set Model AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJY162GALH AJY180GALH AJY198GALH AJY216GALH AJY234GALH AJY252GALH Energy Efficiency Page 158~ Set Model AJY144GALHH AJY198GALHH AJY216GALHH AJY234GALHH AJY252GALHH Space Saving Page 164~ V-III Series Heat Pump Set Model AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY180LALBH AJY198LALBH AJY216LALBH AJY234LALBH AJY252LALBH Energy Efficiency Page 164~ Set Model AJY144LALBHH AJY162LALBHH AJY180LALBHH AJY216LALBHH AJY234LALBHH AJY252LALBHH AIRSTAGE VR-II series Heat Recovery Modular type AIRSTAGE V-III series Heat Pump Modular type Wide operating range Installation in extreme temperature conditions is possible due to an increase in operational range. 46 C & Heating 21 C Heating 21 C 46 C Heating 21 C * Note: When a multiple outdoor unit connection is used. Operating range is from -5 C to 46 C in cooling. -10 C -10 C -20 C -15 C* 8-20 C 146
30 AJY270GALH AJY288GALH AJY306GALH AJY324GALH AJY342GALH AJY360GALH AJY378GALH AJY396GALH AJY414GALH AJY432GALH AJY270GALHH AJY288GALHH AJY306GALHH AJY324GALHH AJY342GALHH AJY360GALHH AJY378GALHH AJY396GALHH AJY270LALBH AJY288LALBH AJY306LALBH AJY324LALBH AJY342LALBH AJY360LALBH AJY378LALBH AJY396LALBH AJY414LALBH AJY432LALBH AJY450LALBH AJY468LALBH AJY486LALBH AJY270LALBHH AJY288LALBHH AJY306LALBHH AJY324LALBHH AJY342LALBHH AJY360LALBHH AJY378LALBHH AJY396LALBHH AJY414LALBHH More Comfort Air conditioning load factor Heat load Quiet priority setting Precision refrigerant flow control Precise and smooth refrigerant flow control is achieved by using a DC Inverter control in conjunction with individual indoor unit electronic expansion valve control. This allows high precision comfortable temperature control of ±0.5 C. Capacity Operating sound 100% 0 58 db 0 Quiet priority low noise mode down time Auto changeover function At Auto setting, the cooling/heating mode is automatically switched according to the set temperature and room temperature. Air conditioning load factor Heat load Capacity priority setting Quiet operation Capacity 100% 0 Alternated automatically Two low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the indoor environment and outside temperature load. This feature can be controlled via outdoor unit external input and/or system controller. Operating sound 58 db 0 Reset automatically Capacity priority low noise mode time 147
31 CORE TECHNOLOGY Energy Efficiency Efficiency is improved significantly by using DC twin rotary compressor, inverter technology, and large heat exchanger %UP! %UP! %UP! 27%UP! New model Previous model EER COP Heat Pump (8HP) V-III Series Heat Recovery (10HP) VR-II Series Energy Saving Function Economy operation Economy operation can be set by remote controller. The temperature setting is offset automatically over a certain period of time. Heating Set Temperature MAX. -4 C Set Temp. Down Down Down Down Economy operation Control Temperature Economy operation Set Temp. Room temperature set point limitation The minimum and maximum temperature ranges can be limited, which provide further energy saving while maintaining the comfort of the occupants. Economy operation Control Temperature MAX. +2 C Set Temperature Economy operation Up Up Auto-off timer The indoor unit automatically is turned off when it reaches the preset operating time frame. The time frame of the "Auto off timer" can be flexibly scheduled. Set interval time (17:00 24:00) ON OFF ON Auto OFF ON Auto OFF Capacity save operation Operation capacity can be set in 5 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed. 1 hour 1 hour Normal Time Over Time
32 Design Flexibility Overall piping length Max. 1,000 m World s top class overall piping length of 1,000 m allows for application in a wide variety of buildings. AIRSTAGE VR-II series & V-III series Actual pipe length Max. 165 m *1 *1: VR-II series & V-III series is max. 150 m Height difference between outdoor and indoor units Max. 50 m For the outdoor unit stated below: 40 m max. Pipe length from first separation tube to the furthest indoor unit Max. 90 m *2*3 Height difference between indoor and indoor units Max. 15 m *2: V-III series. The limitation on the pipe length between the furthest IU and the nearest IU originated from the first separation tube must be 60 m or less. *3: VR-II series is max. 60 m. capacity connection Series Connectable indoor unit capacity range Connectable indoor unit number *5: Conditions of maximum connectable indoor unit capacity ratio is as the chart above. *6: Max. capacities in the combinations including the 18 HP outdoor unit fall below 150%. AIRSTAGE VR-II series Heat Recovery Modular type 50% to 150% *5 up to 64 AIRSTAGE V-III series Heat Pump Modular type 50% to 150% *6 up to
33 LARGE VRF Heat Recovery Modular Type Smart and cutting edge design Extensive lineup from 8HP to 48HP in 2HP increment Connectable indoor unit capacity ratio up to 150% System Outline Simultaneous cooling and heating operation using 1 refrigerant system and heating can be freely selected for each indoor unit to provide simultaneous cooling and heating in the rooms with large temperature differences, etc. Annual cooling operation Use annual cooling operation for the rooms and other spaces that require constant temperature control throughout the year. Handles changes in the temperature difference The operation mode can be freely changed when there are large temperature differences during the day, such as between seasons. 150
34 Features Operating Energy Efficiency Our Heat recovery systems achieve high operating energy efficiency by drawing heat from the room to be cooled and transferring it as energy for rooms that are to be heated. Heat exchanger 4 way valve pressure liquid Low pressure gas pressure gas Compressor Outdoor unit RB unit Indoor unit Heat exchanger EEV Heating Energy saving technology has boosted operation efficiency Powerful large propeller fan By using CFD *1 technology, a newly designed fan achieves high performance and low noise operation. *1. CFD = Computational Fluid Dynamics 3 phase DC fan motor Efficiency is substantially improved by high efficient motor with sophisticated driver control. In addition, low noise is achieved by the DC fan motor. Sine-wave DC inverter control efficiency is achieved by adoption of reduced switching loss IPM. 4-face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4-face heat exchanger that increases effective surface area. Subcool heat exchanger Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. efficient and large capacity DC inverter compressor Large capacity high efficient DC twin rotary compressor with excellent intermediate capability. Front intake port (corner cut air inhaling structure) In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger. 151
35 LARGE VRF Outdoor units lineup Combinations other than the followings are not recommended. Space saving combination 22.4 kw (8HP) 28.0 kw (10HP) 33.5 kw (12HP) 40.0 kw (14HP) 45.0 kw (16HP) AJYA72GALH UNIT : AJYA72GALH AJYA90GALH UNIT : AJYA90GALH AJY108GALH UNIT : AJY108GALH AJY126GALH UNIT : AJY126GALH AJY144GALH UNIT : AJY144GALH 50.4 kw (18HP) 56.0 kw (20HP) 61.5 kw (22HP) 67.0 kw (24HP) 73.0 kw (26HP) AJY162GALH UNIT : AJYA90/A72GALH AJY180GALH UNIT : AJYA90/A90GALH AJY198GALH UNIT : AJY108/A90GALH AJY216GALH UNIT : AJY108/108GALH AJY234GALH UNIT : AJY144/A90GALH 78.5 kw (28HP) 85.0 kw (30HP) 90.0 kw (32HP) 95.0 kw (34HP) kw (36HP) AJY252GALH UNIT : AJY144/108GALH AJY270GALH UNIT : AJY144/126GALH AJY288GALH UNIT : AJY144/144GALH AJY306GALH UNIT : AJY108/108/A90GALH AJY324GALH UNIT : AJY108/108/108GALH kw (38HP) kw (40HP) kw (42HP) kw (44HP) kw (46HP) AJY342GALH UNIT : AJY144/108/A90GALH AJY360GALH UNIT : AJY144/108/108GALH AJY378GALH UNIT : AJY144/144/A90GALH AJY396GALH UNIT : AJY144/144/108GALH AJY414GALH UNIT : AJY144/144/126GALH kw (48HP) AJY432GALH UNIT : AJY144/144/144GALH Energy efficiency combination 44.8 kw (16HP) 62.4 kw (22HP) 67.2 kw (24HP) 72.8 kw (26HP) 78.4 kw (28HP) AJY144GALHH UNIT : AJYA72/A72GALH AJY198GALHH UNIT : AJY126/A72GALH AJY216GALHH UNIT : AJYA72/A72/A72GALH AJY234GALHH UNIT : AJYA90/A72/A72GALH AJY252GALHH UNIT : AJYA90/A90/A72GALH 84.0 kw (30HP) 90.4 kw (32HP) 96.0 kw (34HP) kw (36HP) kw (38HP) AJY270GALHH UNIT : AJYA90/A90/A90GALH AJY288GALHH UNIT : AJY126/A90/A72GALH AJY306GALHH UNIT : AJY126/A90/A90GALH AJY324GALHH UNIT : AJY126/126/A72GALH AJY342GALHH UNIT : AJY126/126/A90GALH kw (40HP) kw (42HP) kw (44HP) AJY360GALHH UNIT : AJY144/126/A90GALH AJY378GALHH UNIT : AJY126/126/126GALH AJY396GALHH UNIT : AJY144/126/126GALH 152
36 8,10,12HP : AJYA72GALH / AJYA90GALH / AJY108GALH 14,16HP : AJY126GALH / AJY144GALH 8, 10, 12 HP 14, 16 HP Dimensions (Unit : mm) 8, 10, 12 HP 690 (Bolt pitch) (Bolt pitch) (Hole) (Bolt pitch) B A C A Front side knockout position 73 Ø Ø 43.7 Ø 50 Power supply cable port Power supply cable port Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port Pipe port 10 14, 16 HP (Bolt pitch) 840 (Bolt pitch) (Hole) B Left side knockout position 732 (Bolt pitch) Ø 50 Power supply cable port Ø 34.5 Power supply cable port Ø 43.7 Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port C Bottom side knockout position 1690 Top view Pipe port B A C 153
37 LARGE VRF Outdoor units specifications Space Saving Combination Rating Capacity range HP Set Model name AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJY162GALH AJY180GALH AJY198GALH AJY216GALH Unit 1 Unit 2 Unit 3 AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJYA90GALH AJYA72GALH AJYA90GALH AJYA90GALH AJY108GALH AJYA90GALH AJY108GALH AJY108GALH Maximum Connectable Indoor Unit* Indoor unit connectable capacity kw Power source 3-phase 4 wire, 400 V, 50Hz Capacity kw Heating Input power kw Heating EER W/W COP Heating W/W m 3 /h 11,100 11,100 11,100 13,000 13,000 11, , , , Sound pressure level* / 56 / / / / / / / / / 83 db(a) Power level Heating 58 / / / / / / / / / 86 Maximum external static pressure Pa Compresor motor output kw Recommended MCB Amp Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 Net Dimensions Width mm ,240 1, Depth Weight kg Refrigerant Type R410A R410A R410A R410A R410A R410A R410A R410A R410A Charge kg Connection pipe diameter Operation range Liquid 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8 Discharge Gas Inch 5/8 3/4 3/4 7/8 7/8 7/8 7/8 1 1/8 1 1/8 Suction Gas 7/8 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8-10 to to to to to to to to to 46 Heating CDB -20 to to to to to to to to to 21 /Heating -10 to to to to to to to to to 21 Energy Efficiency Combination Rating Capacity range HP Set Model name AJY144GALHH AJY198GALHH AJY216GALHH AJY234GALHH AJY252GALHH AJY270GALHH Unit 1 Unit 2 Unit 3 AJYA72GALH AJYA72GALH AJY126GALH AJYA72GALH AJYA72GALH AJYA72GALH AJYA72GALH AJYA90GALH AJYA72GALH AJYA72GALH AJYA90GALH AJYA90GALH AJYA72GALH AJYA90GALH AJYA90GALH AJYA90GALH Maximum Connectable Indoor Unit* Indoor unit connectable capacity kw Power source 3-phase 4 wire, 400 V, 50Hz Capacity kw Heating Input power kw Heating EER W/W COP Heating W/W m 3 /h 11, ,000+11,100 11, , , , Sound pressure level* / 59 / / / / / / 84 db(a) Power level Heating 61 / / / / / / 86 Maximum external static pressure Pa Compresor motor output kw Recommended MCB Amp Height 1,690 1,690 1,690 1,690 1,690 1,690 Net Dimensions Width mm , Depth Weight kg Refrigerant Type R410A R410A R410A R410A R410A R410A Charge kg Liquid 1/2 5/8 5/8 5/8 5/8 3/4 Connection pipe diameter Discharge Gas mm 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 Suction Gas 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8-10 to to to to to to 46 Operation range Heating CDB -20 to to to to to to 21 /Heating -10 to to to to to to Note: Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating: Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length: 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. When cooling operation will be conducted at outdoor air temperature below -5 C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units.
38 AJY234GALH AJY252GALH AJY270GALH AJY288GALH AJY306GALH AJY324GALH AJY342GALH AJY360GALH AJY378GALH AJY396GALH AJY414GALH AJY432GALH AJY144GALH AJYA90GALH AJY144GALH AJY108GALH AJY144GALH AJY126GALH AJY144GALH AJY144GALH AJY108GALH AJY108GALH AJYA90GALH AJY108GALH AJY108GALH AJY108GALH AJY144GALH AJY108GALH AJYA90GALH AJY144GALH AJY108GALH AJY108GALH AJY144GALH AJY144GALH AJYA90GALH AJY144GALH AJY144GALH AJY108GALH AJY144GALH AJY144GALH AJY126GALH AJY144GALH AJY144GALH AJY144GALH phase 4 wire, 400 V, 50Hz ,000+11,100 13,000+11,100 13, , , , ,000+11, ,000+11, , ,100 13, ,100 13, , / / / / / / / / / / / / / / / / / / / / / / / / ,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1, , , , , , , , , , R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A /8 5/8 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8-10 to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to AJY288GALHH AJY306GALHH AJY324GALHH AJY342GALHH AJY360GALHH AJY378GALHH AJY396GALHH AJY126GALH AJYA90GALH AJYA72GALH AJY126GALH AJYA90GALH AJYA90GALH AJY126GALH AJY126GALH AJYA72GALH AJY126GALH AJY126GALH AJYA90GALH AJY144GALH AJY126GALH AJYA90GALH AJY126GALH AJY126GALH AJY126GALH AJY144GALH AJY126GALH AJY126GALH phase 4 wire, 400 V, 50Hz ,000+11, ,000+11, , ,100 13, ,100 13, ,100 13, , / / / / / / / / / / / / / / ,690 1,690 1,690 1,690 1,690 1,690 1,690 1, , , , , , , R410A R410A R410A R410A R410A R410A R410A /4 3/4 3/4 3/4 3/4 3/4 3/4 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8-10 to to to to to to to to to to to to to to to to to to to to to 21 *1: Minimum connectable indoor unit number is 2. *2: The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value. 155
39 LARGE VRF Heat Pump Modular Type Smart and cutting edge design Extensive lineup from 8HP to 48HP in 2HP increment Connectable indoor unit capacity ratio up to 150% System Outline Excellent energy saving Heat pump inverter type achieves high energy saving air conditioning for individual cooling and heating operation by inverter technology for seasonal efficiency. design flexibility for various building air conditioning design flexibility which meets the various needs of high-rise buildings air conditioning. Outdoor unit roof top concentrated installation and each floor installation by large capacity combination, sufficient connection capacity, and high static pressure design. Easy installation and maintenance The flexible communication method and piping connections make installation and maintenance easy even for large systems. 156
40 Features Efficiency in actual operation Top class high COP is achieved for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and our own technologies. Space saving combination (COP) * (HP) (COP) Energy efficiency combination For 24 HP Combination Space saving Energy efficiency * (HP) COP 17% UP Energy saving technology has boosted operation efficiency Powerful large propeller fan By using CFD *1 technology, a newly designed fan achieves high performance and low noise operation. *1. CFD = Computational Fluid Dynamics 3 phase DC fan motor Efficiency is substantially improved by high efficient motor with sophisticated driver control. In addition, low noise is achieved by the DC fan motor. Sine-wave DC inverter control efficiency is achieved by adoption of reduced switching loss IPM. 4-face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4-face heat exchanger that increases effective surface area. Subcool heat exchanger Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. efficient and large capacity DC inverter compressor Large capacity high efficient DC twin rotary compressor with excellent intermediate capability. Front intake port (corner cut air inhaling structure) In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger. 157
41 LARGE VRF Outdoor units lineup Combinations other than the followings are not recommended. Space saving combination 22.4 kw (8HP) 28.0 kw (10HP) 33.5 kw (12HP) 40.0 kw (14HP) 45.0 kw (16HP) AJY072LALBH UNIT : AJY072LALBH AJY090LALBH UNIT : AJY090LALBH AJY108LALBH UNIT : AJY108LALBH AJY126LALBH UNIT : AJY126LALBH AJY144LALBH UNIT : AJY144LALBH 50.0 kw (18HP) 56.0 kw (20HP) 62.4 kw (22HP) 68.0 kw (24HP) 73.0 kw (26HP) AJY162LALBH UNIT : AJY162LALBH AJY180LALBH UNIT : AJY090/090LALBH AJY198LALBH UNIT : AJY126/072LALBH AJY216LALBH UNIT : AJY126/090LALBH AJY234LALBH UNIT : AJY144/090LALBH 78.0 kw (28HP) 85.0 kw (30HP)) 90.0 kw (32HP) 95.0 kw (34HP) kw (36HP) AJY252LALBH UNIT : AJY162/090LALBH AJY270LALBH UNIT : AJY144/126LALBH AJY288LALBH UNIT : AJY144/144LALBH AJY306LALBH UNIT : AJY162/144LALBH AJY324LALBH UNIT : AJY162/162LALBH kw (38HP) kw (40HP) kw (42HP) kw (44HP) kw (46HP) AJY342LALBH UNIT : AJY162/090/090LALBH AJY360LALBH UNIT : AJY144/126/090LALBH AJY378LALBH UNIT : AJY144/144/090LALBH AJY396LALBH UNIT : AJY162/144/090LALBH AJY414LALBH UNIT : AJY162/162/090LALBH kw (48HP) kw (50HP) kw (52HP) kw (54HP) AJY432LALBH UNIT : AJY144/144/144LALBH AJY450LALBH UNIT : AJY162/144/144LALBH AJY468LALBH UNIT : AJY162/162/144LALBH AJY486LALBH UNIT : AJY162/162/162LALBH Energy efficiency combination 44.8 kw (16HP) 50.4kW (18HP) 55.9 kw (20HP) 67.2 kw (24HP) 72.8 kw (26HP) AJY144LALBHH UNIT : AJY072/072LALBH AJY162LALBHH UNIT : AJY090/072LALBH AJY180LALBHH UNIT : AJY108/072LALBH AJY216LALBHH UNIT : AJY072/072/072LALBH AJY234LALBHH UNIT : AJY090/072/072LALBH 78.3 kw (28HP) 84.8 kw (30HP) 89.4 kw (32HP) 95.9 kw (34HP) kw (36HP) AJY252LALBHH UNIT : AJY108/072/072LALBH AJY270LALBHH UNIT : AJY126/072/072LALBH AJY288LALBHH UNIT : AJY108/108/072LALBH AJY306LALBHH UNIT : AJY126/108/072LALBH AJY324LALBHH UNIT : AJY108/108/108LALBH kw (38HP) kw (40HP) kw (42HP) kw (44HP) kw (46HP) AJY342LALBHH UNIT : AJY126/108/108LALBH AJY360LALBHH UNIT : AJY126/126/108LALBH AJY378LALBHH UNIT : AJY126/126/126LALBH AJY396LALBHH UNIT : AJY144/126/126LALBH AJY414LALBHH UNIT : AJY144/144/126LALBH 158
42 8,10HP : AJY072LALBH / AJY090LALBH 12,14,16HP : AJY108LALBH / AJY126LALBH / AJY144LALBH / AJY162LALBH 8, 10 HP 12, 14, 16 HP Dimensions (Unit : mm) 8, 10 HP 690 (Bolt pitch) (Bolt pitch) (Hole) (Bolt pitch) B A C A Front side knockout position 73 Ø Ø 43.7 Ø 50 Power supply cable port Power supply cable port Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port Pipe port 10 12, 14, 16 HP (Bolt pitch) 840 (Bolt pitch) (Hole) B Left side knockout position 732 (Bolt pitch) Ø 50 Power supply cable port Ø 34.5 Power supply cable port Ø 43.7 Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port C Bottom side knockout position 1690 Top view Pipe port B A C 159
43 LARGE VRF Outdoor units specifications Space Saving Combination Rating Capacity range HP Set Model name AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY180LALBH AJY198LALBH AJY216LALBH AJY234LALBH AJY252LALBH Unit 1 Unit 2 Unit 3 AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY090LALBH AJY090LALBH AJY126LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY072LALBH AJY090LALBH AJY090ALBH AJY090LALBH Maximum Connectable Indoor Unit* Indoor unit connectable capacity kw Power source 3-phase 4 wire, 400 V, 50Hz Capacity kw Heating Input power kw Heating EER W/W COP Heating W/W m 3 /h 11,100 11,100 13,000 13,000 13,700 13,700 11, ,000+11,100 13,000+11,100 13,000+11,100 13,700+11,100 2 Sound pressure level* / 56 / / / / / / / / / / / 85 db(a) Power level Heating 58 / / / / / / / / / / / 87 Maximum external static pressure Pa Compresor motor output kw Minimum Recomended MCB Amp Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 Net Dimensions Width mm ,240 1,240 1,240 1, , , , , Depth Weight kg Refrigerant Type R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A Charge kg Connection pipe Liquid 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8 5/8 5/8 inch diameter Gas 7/8 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 Operation range -15 to to to to to to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46 CDB Heating -20 to to to to to to to to to to to 21 Energy Efficiency Combination Rating Capacity range HP Set Model name AJY144LALBHH AJY162LALBHH AJY180LALBHH AJY216LALBHH AJY234LALBHH AJY252LALBHH AJY270LALBHH Unit 1 Unit 2 Unit 3 AJY072LALBH AJY072LALBH AJY090LALBH AJY072LALBH AJY108LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY090LALBH AJY072LALBH AJY072LALBH AJY108LALBH AJY072LALBH AJY072LALBH AJY126LALBH AJY072LALBH AJY072LALBH Maximum Connectable Indoor Unit* Indoor unit connectable capacity kw Power source 3-phase 4 wire, 400 V, 50Hz Capacity kw Heating Input power kw Heating EER W/W COP Heating W/W m 3 /h 11, , ,000+11,100 11, , ,000+11, ,000+11, Sound pressure level* / 59 / / / / / / / 84 Power level db(a) Heating 61 / / / / / / / 87 Maximum external static pressure Pa Compresor motor output kw Minimum Recomended MCB Amp Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 Net Dimensions Width mm , , , Depth Weight kg Refrigerant Charge R410A R410A R410A R410A R410A R410A R410A Charge kg Connection pipe Liquid 1/2 5/8 5/8 5/8 5/8 5/8 3/4 Inch diameter Gas 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 Operation range -5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46 CDB Heating -20 to to to to to to to 21 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. When cooling operation will be conducted at outdoor air temperature below -5 C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units. 160
44 AJY270LALBH AJY288LALBH AJY306LALBH AJY324LALBH AJY342LALBH AJY360LALBH AJY378LALBH AJY396LALBH AJY414LALBH AJY432LALBH AJY450LALBH AJY468LALBH AJY486LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY126LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY090LALBH AJY090LALBH AJY144LALBH AJY126LALBH AJY090LALBH AJY144LALBH AJY144LALBH AJY090LALBH AJY162LALBH AJY144LALBH AJY090LALBH AJY162LALBH AJY162LALBH AJY090LALBH AJY144LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY162LALBH phase 4 wire, 400 V, 50Hz ,700+13,000 13, , , ,700+11, ,700+13,000+11,100 13, ,100 13, ,100 13, ,100 13, , , , / / / / / / / / / / / / / / / / / / / / / / / / / / ,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1, , , , , , , , , , , , , R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A /4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 3/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to to to to to to to to to to to to to to AJY288LALBHH AJY306LALBHH AJY324LALBHH AJY342LALBHH AJY360LALBHH AJY378LALBHH AJY396LALBHH AJY414LALBHH AJY108LALBH AJY108LALBH AJY072LALBH AJY126LALBH AJY108LALBH AJY072LALBH AJY108LALBH AJY108LALBH AJY108LALBH AJY126LALBH AJY108LALBH AJY108LALBH AJY126LALBH AJY126LALBH AJY108LALBH AJY126LALBH AJY126LALBH AJY126LALBH AJY144LALBH AJY126LALBH AJY126LALBH AJY144LALBH AJY144LALBH AJY126LALBH phase 4 wire, 400 V, 50Hz , ,100 13, ,100 13, , , , ,700+13, , , / / / / / / / / / / / / / / / / ,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1, , , , , , , , R410A R410A R410A R410A R410A R410A R410A R410A /4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to 46-5 to to to to to to to to to 21 *1 Minimum connectable indoor unit number is 2. However ARXC72 and ARXC90 can be used signal connection. *2 The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value. 161
45 PRODUCTS LINEUP VRF Indoor Units Capacity range (kw) Model code Compact AUXB04GBLH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH Cassette 4-way Flow (Low height) 4-way Flow (Standard height) AUXD18GALH NEW Circular Flow AUXK018GLAH W Bulkhead Unit (With drain pump) ARXK07GCLH ARXK09GCLH ARXK12GCLH Duct Slim Duct (With drain pump) Medium Static Pressure Duct NEW ARXD04GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH Static Pressure Duct NEW Compact Floor AGYA007GCAH AGYA009GCAH AGYA012GCAH AGYA014GCAH Floor Floor (*Same as Ceiling models) ABYA12GATH ABYA14GATH ABYA18GATH Slim Concealed Floor (*Same as Slim Duct models) ARXD04GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH Ceiling ABYA12GATH ABYA14GATH ABYA18GATH Wall Mounted ASYA04GACH ASYA07GACH ASYA09GACH ASYA12GACH ASYA14GACH ASYA18GACH Wall Mounted Wall Mounted (EEV external) NEW Wall Mounted ASYE04GACH ASYE07GACH ASYE09GACH ASYE12GACH ASYE14GACH With this model, connection of EV kit is necessary. ASYA07GTAH ASYA09GTAH ASYA18GBCH 162
46 AUXB24GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH AUXK024GLAH AUXK030GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH ARXD24GALH ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH ARXC36GBTH ARXC45GATH ARXC60GATH ARXC72GBTH ARXC90GBTH ARXC96GATH ABYA24GATH ARXD24GALH ABYA24GATH ABYA30GATH ABYA36GATH ABYA45GATH ABYA54GATH ASYA24GACH ASYA30GACH ASYA24GBTH ASYA30GTAH ASYA34GTAH *: ARXC60/72/90/96 cannot be connected to JIIS, JII or JIII series. 163
47 VRF Indoor Units for VRF Specifications Wall Mounted Model name ASYA04GACH ASYA07GACH ASYA09GACH ASYA12GACH ASYA14GACH ASYE04GACH ASYE07GACH ASYE09GACH ASYE12GACH ASYE14GACH Power source Single-phase, ~230V, 50Hz Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W Med m 3 /h 370/440 htg/clg* /440 htg/clg* Low 320/420 htg/clg* 1 370/420 htg/clg* 1 370/420 htg/clg* /420 htg/clg* 1 370/420 htg/clg* 1 370/420 htg/clg* Sound pressure level Med db(a) 27/32 htg/clg* /31 htg/clg* Low 22/31 htg/clg* 1 27/31 htg/clg* 1 27/31 htg/clg* /30 htg/clg* 1 26/30 htg/clg* 1 26/30 htg/clg* Dimensions (H W D) mm Weight kg 9 9 Connection Liquid (Flare) 1/4 1/4 Inch pipe diameter Gas (Flare) 1/2 1/2 EV Kit (option) - UTR-EV09XB UTR-EV14XB Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. *1 : This value is under cooling operation. 164
48 Wall Mounted Model name ASYA18GACH ASYA24GACH ASYA30GACH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,100 1,240 Med m 3 /h Low Sound pressure level Med db(a) Low Dimensions (H W D) mm Weight kg 15 Connection Liquid (Flare) 3/8 Inch pipe diameter Gas (Flare) 5/8 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 4-way Compact Cassette Model name AUXB04GALH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,030 Med m 3 /h 420/450 htg/clg* Low 300/350 htg/clg* Sound pressure level Med db(a) 28/30 htg/clg* Low 21/25 htg/clg* Dimensions (H W D) mm (Grille ) Weight kg 15 (Grille 2.6) 17 (Grille 2.6) Connection Liquid (Flare) 1/4 3/8 Inch pipe diameter Gas (Flare) 1/2 5/8 Cassette Grille Model name UTG-UFYC-W Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. *1: This value is under cooling operation. 4-way Cassette Model name AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,150 1,280 1,600 1,800 1,900 2,000 Med m 3 /h 940 1,040 1,300 1,300 1,370 1,370 Low ,100 1,100 1,100 1, Sound pressure level Med db(a) Low Dimensions (H W D) mm (Grille ) (Grille ) Weight kg 22 (Grille 5.5) 27 (Grille 5.5) Connection Liquid (Flare) 3/8 Inch pipe diameter Gas (Flare) 5/8 3/4 Cassette Grille Model name UTG-UGYA-W Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. *1: This value is under cooling operation. 165
49 VRF Indoor Units for VRF Specifications Bulkhead Duct Model name ARXK07GCLH ARXK09GCLH ARXK12GCLH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W Med m 3 /h Low Static pressure range 0 to 30 0 to 30 0 to 30 Pa Standard static pressure Sound pressure level Med db(a) Low Dimensions (H W D) mm Weight kg Connection Liquid (Flare) 1/4 Inch pipe diameter Gas (Flare) 1/2 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. Slim Duct / Slim Concealed Floor Model name ARXD04GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,330 Med m 3 /h 400/470 htg/clg* ,240 Low 320/440 htg/clg* ,100 Static pressure range 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 50 Pa Standard static pressure Sound pressure level Med db(a) 21/25 htg/clg* Low 20/22 htg/clg* Dimensions (H W D) mm , Weight kg Connection Liquid (Flare) 1/4 3/8 Inch pipe diameter Gas (Flare) 1/2 5/8 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. *1: This value is under cooling operation. Medium Static Pressure Duct Model name ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,280 1,410 1,840 1,970 Med m 3 /h 990 1,280 1,600 1,860 Low 840 1,150 1,470 1,640 Static pressure range 0 to to to to 150 Pa Standard static pressure Sound pressure level Med db(a) Low Dimensions (H W D) mm 270 1, Weight kg Connection Liquid (Flare) 3/8 Inch pipe diameter Gas (Flare) 5/8 3/4 166 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
50 Static Pressure Duct Model name ARXC36GBTH ARXC45GATH ARXC60GATH* ARXC72GBTH ARXC90GATH ARXC96GATH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,990 3,500 3,500 3,900 4,300 4,850 Med m 3 /h 1,680 3,000 3,000 3,300 4,000 4,250 Low 1,330 2,460 2,460 3,000 3,500 3,600 Static pressure range 0 to to to to to to 300 Pa Standard static pressure Sound pressure level Med db(a) Low Net Dimensions (H W D) mm 400 1, , , Weight kg Connection Liquid 3/8 (Flare) 1/2 (Brazing) inch pipe diameter Gas 3/4 (Flare) 7/8 (Brazing) Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. Floor/Ceiling Model name ABYA12GATH ABYA14GATH ABYA18GATH ABYA24GATH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,000 1,000 Med m 3 /h Low Sound pressure level Med db(a) Low Dimensions (H W D) mm Weight kg Connection Liquid (Flare) Inch 1/4 3/8 pipe diameter Gas (Flare) 1/2 5/8 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. Ceiling Model name Power source Capacity Input power Sound pressure level Dimensions (H W D) Weight Connection pipe diameter UK Total UK Sensible UK Heating Nominal Nominal Heating Med Low Med Low Liquid (Flare) Gas (Flare) kw W m 3 /h db(a) mm kg Inch ABYA30GATH ABYA36GATH ABYA45GATH ABYA54GATH Single-phase, ~230V, 50Hz ,630 1,690 2,010 2,270 1,370 1,400 1,600 1,780 1,140 1,170 1,230 1, , /8 3/8 5/8 3/4 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 167
51 VRF NEW Indoor Units for VRF Specifications Circular Flow Cassette NEW Model name AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,420 1,420 1,440 1,620 1,820 2,040 Med-H 1,360 1,360 1,440 1,500 1,590 1,800 Med m 3 1,300 1,300 1,340 1,400 1,500 1,590 /h Med-L 1,270 1,270 1,300 1,340 1,400 1,440 Low 1,200 1,200 1,280 1,280 1,300 1,300 Quiet 1,150 1,150 1,150 1,150 1,150 1, Med-H Sound pressure level Med db(a) Med-L Low Quiet Dimensions (H W D) mm 288 x 840 x 840 (Grille ) Weight kg 26.5 (Grille 6.0) 29.5 (Grille 6.0) Connection Liquid (Flare) 3/8 pipe diameter Inch Gas (Flare) 5/8 Cassette Grille Model name UTG-UKYC-W Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. When AUX*018GLAH is connected to the outdoor unit other than J-IIIL, pipe diameter should be 3/8 &5/8 (Liq/Gas) When AUXK036GLAH, AUXK045GLAH, and AUXK054GLAH are connected to the outdoor unit other than J-IIIL, gas pipe diameter should be 3/4 Wall Mounted NEW Model name ASYA007GTAH ASYA009GTAH ASYA18GBCH ASYA24GBCH ASYA030GTAH ASYA034GTAH Power source Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W ,100 1,440 1,620 / 1,520 Med-H ,200 1,300 Med m ,050 1,120 /h Med-L Low Quiet / 54 Med-H Sound pressure level Med db(a) Med-L Low Quiet Dimensions (H W D) mm 262 x 820 x x 998 x x 1,150 x 280 Weight kg Connection Liquid (Flare) Inch 1/4 3/8 pipe diameter Gas (Flare) 3/8 1/2 5/8 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. When ASYA18GBCH is connected to the outdoor unit other than J-IIIL, pipe diameter should be 3/8 & 5/8 (Liq/Gas). When ASY*007GTAH, ASY*009GTAH are connected to the outdoor unit other than J-IIIL, gas pipe diameter should be 1/2. 168
52 Compact Floor NEW Model name Power source AGYA007GCAH AGYA009GCAH AGYA012GCAH AGYA014GCAH Single-phase, ~230V, 50Hz UK Total UK Sensible Capacity UK Heating kw Nominal Nominal Heating Input power W Med-H Med m /h Med-L Low Quiet Med-H Sound pressure level Med db(a) Med-L Low Quiet Dimensions (H W D) mm 600 x 740 x 200 Weight kg 15 Connection Liquid (Flare) 1/4 Inch pipe diameter Gas (Flare) 3/8 1/2 Note : Specifications are based on the following conditions. : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. When AGY*007GCAH, and AGY*009GCAH are connected to the outdoor unit other than J-IIIL, gas pipe diameter should be 1/2. Linwood now offer an extensive range of plenum boxes to suit the Fujitsu General Air Conditioning UK range of ducted air conditioning indoor units Installing air conditioning ducted fan coil units (FCU's) just got easier with these purpose made plenum boxes designed to save you time and money when fitting VRF or split air conditioning systems Easy to use online ordering & live order processing via Contact details: Linwood Plenums Ltd 138 Riverside Mansions Milk Yard London E1W 3SX Sales@linwoodplenums.co.uk Tel: Mob:
PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL
IRSTGE Systems can be designed to create an air conditioning solution to suit most buildings requirements. IRSTGE Systems can be designed to effectively provide an air conditioning solution from a large
More informationThe AIRSTAGE J-II Series adopts the best technology. and was designed with the greatest care to provide not
The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only energy savings and comfort but also ease of design, installation, and maintenance. Fujitsu
More informationmodular multi intelligent, environmental and versatile
modular multi intelligent, environmental and versatile system overview 2-pipe R407C heat pump VRF system From 8 to 46 HP in one piping system (19 steps) Active leak detection system option Up to 40 indoor
More informationPRODUCT LINEUP MULTI SPLIT
068 PRODUCT LINEUP Energy saving design to provide a comfortable indoor environment while being environment-friendly. An air conditioner that is people-friendly is also environment friendly. Fujitsu General
More informationDC INVERTER VRF SYSTEMS C-VRF
DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor
More informationMidea VRFs/ Midea V5X. Timothy Huang Senior Engineer
Midea VRFs/ Midea V5X Timothy Huang Senior Engineer VRF Product Overview General Features V5X Key Technologies V5X VRF product strategy VRF line-up Fresh air solutions Selection software Unique Innovations
More informationFULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS COMMERCIAL AIR CONDITIONERS SDV4 2014 AIR CONDITIONING 1 WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation
More informationAIR CONDITIONING SYSTEMS. Debuting the New Multi System MXZ-5A100VA. Maximum comfort for 5 rooms, using 1 outdoor unit
AIR CONDITIONING SYSTEMS Debuting the New Multi System Maximum comfort for 5 rooms, using 1 outdoor unit Debut of the New Multi System Built to Serve up to Five Rooms in All! N e w One Outdoor Unit Handling
More informationAir Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB
Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................
More informationDC INVERTER DUCTED AIR CONDITIONERS
DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More informationAir Conditioning. Technical Data EEDEN RXZ-N
Air Conditioning Technical Data EEDEN14-100 RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................
More informationNew ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by
New ECOi Electric 2 and 3 pipe VRF systems 2006/7 Range 1 All round air conditioning by ECOi the next generation of 2 and 3 pipe electric SANYO is justifi ably proud of being renowned for developing unique
More informationPREMIUM INVERTER DUCTED AIR CONDITIONING
PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic
More informationVRF Mini Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group
Coercial Air Conditioners 16 VRF Mini Series 50Hz Midea CAC After-service Application Midea CAC News Application Coercial Air Conditioner Division Midea Group Add.: West Region of Midea Coercial Air Conditioner
More informationYCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO
YCZ RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO q Multi line available in four capacities from 5.2 up to 10.5 kw. q DC Inverter and sine wave compressor drive technology. q Match with high wall, ducted,
More informationRESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS
RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic s
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationAir Conditioning. Technical Data EEDEN RXZ-N
Air Conditioning Technical Data EEDEN15-100 RXZ-N Outdoor Unit RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationContents. Contents SYSTEM SYSTEM SYSTEM
SYSTEM SYSTEM SYSTEM Contents Contents Lineup & Feature - Outdoor Units One Outdoor Unit, Multiple Indoor Units Twin BLDC Compressor Sine Wave Controller Current Wave Torque Ripple Current Wave Torque
More informationAir Conditioning System
For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 00 Air Conditioning System 00 Air Conditioning System Enjoy a clean
More informationInnovair VRF Full DC Inverter Technology (50/60 Hz)
Innovair VRF Full DC Inverter Technology (/60 Hz) R-410 Contents 1 2 3 4 5 6 7 8 9 10 11 13 Innovair Full DC Inverter Technology High efficiency and more energy saving Two-stage oil separation control
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP
VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance
More information40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw
LLOYD'S REGISTER QUALITY ASSURANCE Direct expansion split system Inverter Cassette I S O 9 00 1 40KQV Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw 40KQV cassette belongs
More informationResolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h
Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:
More informationModels: 12 and 18. Models: 24 to 60
SPLIT CASSETTE TYPE MUCSR-H8 Series SCOP 4.0 Models: 12 and 18 RG57B2/BGE Included (CL 94 982) Models: 24 to 60 Design 360 Thanks to the 360 panel design, the air is more evenly distributed. Drainage pump
More informationLG HVAC SOLUTION. LG Electronics. Distributed by. Copyright 2017 LG Electronics. All rights reserved.
2 0 1 7 2017 LG HVAC SOLUTION LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. ULTIMATE INVERTER COMPRESSOR As the core technology
More informationM1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT
VRF SYSTEMS M TYPE SIM VARIABE STATIC PRESSURE IDE AWAY CONCEAED DUCT The ultra slim M type is one of the leading products of its type in the industry. With a depth of only mm it provides greater flexibility
More informationceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system
ceiling wall Large and wide airflow High efficiency Low noise Large centre display Easy maintenance Inverter options Automatic filter cleaning options Easy-to-use remote controller AWYZ14LB/18LB With the
More informationAir Cooled Packaged Units
Air Cooled Packaged Units Technical Data OPA 465, OPA 550, OPA 705, OPA 855, OPA 960 (ECO) Cooling Capacity 44.9kW - 96.0kW Heating Capacity 41.1kW - 90.0kW Contents OPA 465 960 ECO 3 General 3 Applications
More informationPRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)
PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111
More informationDuctless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018
Higher Comfort, Haier Living 2018 MRV-S (Mini VRF) Product Brochure rev 01012018 Ductless HAIER MRV MILESTONES MRV-S KEY FEATURES Haier is one of the leading producers of HVAC products, having the capacity
More information1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...
MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...
More informationCompact Four-way Cassette Type
1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...
More informationHPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM
1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationSINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU
SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big
More informationProduct Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015
Product Catalog Variable Refrigerant Flow (VRF) Mid-Static Concealed (Ducted) Indoor Units Indoor Unit Model number: 4TVD****C***** November 2015 VRF-PRC026A-EN Introduction Trane variable refrigerant
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationSPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................
More informationHitachi Multizone Heat Pump Air Conditioning
Cooling 1.5 13.2 Heating 1.5 14.4 Hitachi Heat Pump Air Conditioning Giving you complete control Zone control that s fast, efficient and clean Imagine being able to rapidly adjust the comfort levels in
More informationAHN 064 to 304 EHN/CHN 064 to 304
u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description
More informationDuctless F L EXIBIL ITY IS F R EEDOM. Fl ex Fit d uc t l ess system. Higher Comfort, Haier Living
Ductless F L EXIBIL ITY IS F R EEDOM I n t ro d uc in g t h e H a ie r Fl ex Fit d uc t l ess system A What is FlexFit? FlexFit is a top-of-the-line modular system that allows for optimal ductless pairings
More informationHigh Wall Type ( 2 Series )
Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationAir Conditioning System
Outdoor Unit For continual product development, LG reserves the right to change specifications without notice. LG Electronics Inc. Printed in Korea December. 00 Designed by crimad. 0 MULTI V MINI MULTI
More informationCool with the sun and save 60% of your power
Cool with the sun and save 60% of your power Saves up to 60% of your electrical power Same prices as non solar systems (incl. panel!) Top technology with attractive indoor units Heat pump for cooling and
More informationISO E5
R410 2013 13P01E Line up Hyper Inverter 1.5 2 2.5 3 4 5 6 8 10 - - HP Our new advanced technology has realized high efficiency, strong heating and long piping. This contributes to the environmental protection
More information24% higher part-load efficiency saves running costs.
Danfoss Scroll Compressors SH485 The family is growing Get more for less with the big blue The unique design of the SH485 offers a compact and innovative 40-ton capacity scroll in the size of a 30-ton
More informationVRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series
VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...
More informationAir Conditioning Technical Data RZQG-L(8)Y1
Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................
More informationFour-way Cassette Type
Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...
More informationSplit. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B
Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................
More informationSplit-Sky Air FDYP-B7 Concealed Ceiling Unit
TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the
More informationPERFECTLY EVEN COOLING CIRCULAR DESIGN 360 CASSETTE. The World s First Circular Cassette. Circular LED Display Window. 360 Air Flow Blade-less
Air Conditioning Solutions 2016 360 CASSETTE CIRCULAR DESIGN Its full-circle design allows it to be placed beautifully in any setting. PERFECTLY EVEN COOLING Innovative 360 degree airflow ensures optimal
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationQ6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationPRODUCT LINEUP SPLIT SYSTEMS
018 PRODUCT LINEUP SYSTEMS Energy saving design to provide a comfortable indoor environment while being environmentally friendly. An air conditioner that is people-friendly is also environmentally friendly.
More informationDigital Inverter 4 series
TCTC-E14-LC005-2 Digital Inverter 4 series Outdoor Unit RAV-SM304ATP-E RAV-SM304ATJP-E RAV-SM4ATP-E RAV-SM4ATJP-E I ndoor Unit RAV-SM307KRTP-E RAV-SM7KRTP-E RAV-SM7CTP-E RAV-SM304MUT-E RAV-SM4MUT-E RAV-SM304SDT-E
More informationLandmark Rooftop Packaged Units
Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop
More informationSwegon PACIFIC. Integrated climate beam
Swegon Integrated climate beam www.eurovent-certification.com www.certiflash.com climate beam The is a high performance climate beam for installation in false ceilings. With high built-in flexibility,
More informationTSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker
HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationCeiling Mount Type Ventilating Fan
Ceiling Mount Type Ventilating Fan Introduction 11-12 DC Motor Series 13-14 Super Quiet Series 15-18 Standard Series 19 10 These fans are installed in the ceiling connected with ductwork, by which indoor
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationLARGE CAPACITY AIR CONDITIONERS 2012 / EVERy BUILDING MATTERS
LARGE CAPACITY AIR CONDITIONERS 2012 / 2013 EVERy BUILDING MATTERS Panasonic Air Conditioning Designed To Care For Your Projects With more than 30 years of experience, exporting to more than 120 countries
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV
Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................
More informationR410A DC Inverter Individual V4 Plus 50Hz 2012
MCAC-2012-05 R410A DC Inverter Individual V4 Plus 50Hz 2012 Commercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea commercial air conditioner
More information1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units
t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to
More informationAir-Cooled Liquid Chiller with integrated hydraulic module
Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800
More informationSplit-Sky Air FAYP-B Wall Mounted Unit
TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More informationAir Conditioning. SEZ-KD Inverter Heat Pump. Product Information. Ceiling Concealed Ducted System
SEZ-KD Inverter Heat Pump Ceiling Concealed Ducted System SEZ-KD Inverter Heat Pump Ceiling Concealed Ducted System Designed for offices, restaurants or shops, the SEZ-KD series operates at low noise levels.
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationDUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME
DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the
More informationMultizone Multi Split systems
19 Multizone Multi Split systems Features and Benefits 2 Room 3 Room 4 Room 5 Room 6 Room RAM-36NP2A RAM-53NP2A RAM-53NP3A RAM-68NP3A RAM-70NP4A RAM-90NP5A RAM-130NP6A Nominal Cooling Capacity (kw) 3.6
More informationCXAM. Options. Accessories
CXAM Reversible air-to-water scroll heat pump Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationThe Mr Slim Inverter Cassette Range
The Mr Slim Inverter Cassette Range Mr Slim Inverter Cassette Range Ideal for use in small offices, retail and leisure The Mr Slim Inverter Cassette Range offers customers all the features and benefits
More informationService manual MIV V4+ Indoor units
Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PPG2GI M1200 Product Line Single Packaged Gas/Electric Units 20 SEER, 81% AFUE 2-5 Ton Units Multi-Stage Cool / Two-Stage Heat The iq Drive gas/electric packaged system features
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable
More informationVARIABLE CAPACITY COMMERCIAL SERIES Premium performance, flexible controls.
Commercial Premium performance, flexible controls. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. Advanced performance with flexible options. The year 1984
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology
More informationAFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components
AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationRPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.
RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit
More informationTECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS
TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to
More informationVRF (System Air-Conditioner)
The World Leader in Air-Conditioning, Heating & Home Appliances Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. Best in Class
More informationStylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a
Stylus 4G Mini Split Air Conditioners Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Comfort Solutions Trane proudly presents the Stylus 4G air conditioners
More informationSINGLE PACKAGE HEAT PUMPS
SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections
More informationCOMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS
2010 COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS COMMERCIAL WELCOME TO COMMERCIAL RANGE Welcome to Commercial range. Welcome to healthier air. A range which confi rms its commitment
More informationModel RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2
2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit
More informationOperating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16
SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT
More informationChiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.
Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.
More information