SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES
|
|
- Chastity Shields
- 5 years ago
- Views:
Transcription
1 SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES 08
2 CONTENTS Smoke extraction systems page 4 JAF axial jet fans page 6 ICF impulse centrifugal fans page 0 Ventilation system for underroof parking page VENTS. Smoke extraction ventilation for parking premises
3 SMOKE EXTRACTION SYSTEMS guide shutters mounting bracket protecting grille electric motor with impeller sound insulating layer 4 VENTS. Smoke extraction ventilation for parking premises JAF axial jet fan application construction
4 Smoke control is a complex process involving smoke extraction and fresh air supply by the supply and extract ventilation system of buildings in order to ensure safe evacuation of people in case of a fire in any of the spaces. Ventilation systems for underroof parking are designed to ensure the most important functions. Such systems are designed to protect people escaping fire through the evacuation routes against hazardous fire factors by extracting harmful combustion products and preventing their spreading in the air. According to conclusive evidence the majority of mortalities in a fire are caused by poisoning from carbon monoxide and other combustion products. Carbon monoxide is one of the most toxic smoke components. It is carbon monoxide poisoning that accounts for 80 % the fire accident causes. Fires in closed spaces where oxygen supply is limited are especially prone to intensive carbon monoxide generation. Smoke is able to cause loss of consciousness and cardiac standstill before a person may leave a house on fire. Jet ventilation system is the most suitable and safe ventilation solution for modern underground parkings. Arrangement of such ventilation requires no ductwork layout, thus the involved mounting expenses are reduced by 45 %. The energy losses caused by aerodynamic resistance in the air ducts are also reduced. The jet ventilation system design requires no complicated annual cleaning of the ductworks, thus reducing the maintenance costs by %. Jet axial fans are used for general ventilation purposes of underground and semiopened parkings, covered shelters, ventilation of tunnels, air recirculation in atriums and air supply to panoramic glass constructions. Such ventilation system does not require installation of ductworks and the air stream flows directly from air supply vent to air exhaust vent. Impurity content in the air [mg/m 3 ] and health effect Influence СО SO NOx No marked effect in case of exposure for several hours Symptoms of light poisoning or mucous membrane irritation in -3 hours Poisoning in 30 minutes Life hazard even if short-term exposure Content, volume in % Petrol type Diesel type N O H O (vapours) CO CO* Nitrogen oxide* Hydrocarbons* Aldehydes* Soot g/m³ Benzpyrene 3.4 g/m³ 0-0 x x 0-6 ICF impulse centrifugal fan construction mounting bracket casing impeller deflector plates protecting grille VENTS. Smoke extraction ventilation for parking premises
5 JET AXIAL FANS JAF series Unidirectional single- and double-speed reversible fans Application JAF jet axial fans are designed for general purpose ventilation of underground and semiopened parkings, ventilation of tunnels, smoke extraction in case of fire as a part of smoke extract system. The fans generate a high-speed and high-pressure directed air jet. Motor Three-phase asynchronous short-circuit rotor motor in the fan casing. Motor ingress protection rating is IP54. The motor design ensures operation of the fan in the smoke extract systems on unidirectional and reverse modes. Axial jet fans with fire resistance 00 C/ hrs, 300 C/ hrs, 400 C/ hrs for ventilation of covered parkings. Functionality. Power. Efficiency. Modifications Unidirectional single-speed type (U) Unidirectional double-speed type (U) Reversible single-speed (R) Reversible double-speed (R) Design JAF casing has a tubular shape and is made of galvanized polymer coated steel. The fan has a sound insulation of mineral wool. The casing includes inner brackets for motor fixation. These brackets act as directing vanes and distribute air flow uniformly, thus increasing aerodynamic performances of the fan. Impeller Dynamically balanced impeller made of cast aluminium. The reversible fans are equipped with 00 % reversible two-directional impeller. Mounting JAF fans are designed for horizontal ceiling mounting and fixation by means of the supplied fixing brackets attached to the fan casing. Dimensions [mm] ØD A B Н L L Unidirectional JAF-KI H JAF-KI JAF-KI JAF-KI JAF-KI ØD L L Reversible JAF-KI-35-R JAF-KI JAF-KI-355-R JAF-KI-400-R JAF-KI-450-R JAF-KI-500-R Casing type Casing insulation Diameter [mm] High-powered motor Pole number Air flow Climatic category Fire resistance limit/hrs JAF (jet axial fan) K: round no symbol means no sound insulation I: soundinsulated casing no symbol means the only available standard size M, S: model with a high-power motor 4 /4 (applicable for doublespeed motors) U: unidirectional R: reversible U: moderate climate ( C) HL: cold climate ( C) UHL: moderate and cold climate ( C) T: tropical climate ( C) M: maritime moderately cold climate ( C) O: general climatic modification (except maritime climate) ( C) OM: general maritime climatic modification ( C) V: universal climatic modification ( C) no number: max. +55 C 00/: 00 С/ hrs. 300/: 300 С/ hrs. 400/: 400 С/ hrs. 6 VENTS. Smoke extraction ventilation for parking premises 03-08
6 Technical data Ø [mm] Air flow direction Uni-directional Reversible Uni-directional Reversible Number of speeds 400 Uni-directional JAF-KI-35--U Unit voltage [V] Frequence [Hz] Power [kw] Max. air capacity [m 3 /h] Fan pull [N] Air speed [m/s] RPM Operating temperature [ C] Fire resistance JAF-KI-35--U-00/ 00 C/ h F00 3~ JAF-KI-35--U-300/ 300 C/ h F300 JAF-KI-35--U-400/ 400 C/ h F400 JAF-KI-35M--U JAF-KI-35M--U-00/ 00 C/ h F00 3~ JAF-KI-35M--U-300/ 300 C/ h F300 JAF-KI-35M--U-400/ 400 C/ h F400 JAF-KI-35-/4-U JAF-KI-35-/4-U-00/ 4000 / 3~ / 0. / / 7. JAF-KI-35-/4-U-300/ 000 JAF-KI-35-/4-U-400/ 400 C/ h F400 JAF-KI-35M-/4-U JAF-KI-35M-/4-U-00/ 4800 / 3~ / / / 8.6 JAF-KI-35M-/4-U-300/ 400 JAF-KI-35M-/4-U-400/ 400 C/ h F400 JAF-KI-35--R JAF-KI-35--R-00/ 00 C/ h F00 3~ JAF-KI-35--R-300/ 300 C/ h F300 JAF-KI-35--R-400/ 400 C/ h F400 JAF-KI-35-/4-R JAF-KI-35-/4-R-00/ 4000 / 3~ / 0. / / 7. JAF-KI-35-/4-R-300/ 000 JAF-KI-35-/4-R-400/ 400 C/ h F400 JAF-KI-355--U JAF-KI-355--U-00/ 00 C/ h F00 3~ JAF-KI-355--U-300/ 300 C/ h F300 JAF-KI-355--U-400/ 400 C/ h F400 JAF-KI-355M--U JAF-KI-355M--U-00/ 00 C/ h F00 3~ JAF-KI-355M--U-300/ 300 C/ h F300 JAF-KI-355M--U-400/ 400 C/ h F400 JAF-KI-355-/4-U JAF-KI-355-/4-U-00/ 5900 / 3~ / / / 8. JAF-KI-355-/4-U-300/ 900 JAF-KI-355-/4-U-400/ 400 C/ h F400 JAF-KI-355M-/4-U JAF-KI-355M-/4-U-00/ 6900 / 3~ / / 9.5 / 9.6 JAF-KI-355M-/4-U-300/ 3400 JAF-KI-355M-/4-U-400/ 400 C/ h F400 JAF-KI-355--R JAF-KI-355--R-00/ 00 C/ h F00 3~ JAF-KI-355--R-300/ 300 C/ h F300 JAF-KI-355--R-400/ 400 C/ h F400 JAF-KI-355-/4-R JAF-KI-355-/4-R-00/ 5900 / 3~ / / / 8. JAF-KI-355-/4-R-300/ 900 JAF-KI-355-/4-R-400/ 400 C/ h F400 JAF-KI-400--U JAF-KI-400--U-00/ 00 C/ h F00 3~ JAF-KI-400--U-300/ 300 C/ h F300 JAF-KI-400--U-400/ 400 C/ h F400 JAF-KI-400M--U JAF-KI-400M--U-00/ 00 C/ h F00 3~ JAF-KI-400M--U-300/ 300 C/ h F300 JAF-KI-400M--U-400/ 400 C/ h F400 VENTS. Smoke extraction ventilation for parking premises
7 JET AXIAL FANS Ø [mm] Air flow direction Number of speeds Uni-directional Reversible Uni-directional Reversible JAF-KI-400-/4-U Unit voltage [V] Frequence [Hz] Power [kw] Max. air Air speed capacity Fan pull [N] [m/s] [m 3 /h] RPM Operating temperature [ C] Fire resistance JAF-KI-400-/4-U-00/ 8500 / 3~ / / / 9.3 JAF-KI-400-/4-U-300/ 400 JAF-KI-400-/4-U-400/ 400 C/ h F400 JAF-KI-400M-/4-U JAF-KI-400M-/4-U-00/ 9900 / 3~ / / 9.9 / 0.9 JAF-KI-400M-/4-U-300/ JAF-KI-400M-/4-U-400/ 400 C/ h F400 JAF-KI-400--R JAF-KI-400--R-00/ 00 C/ h F00 3~ JAF-KI-400--R-300/ 300 C/ h F300 JAF-KI-400--R-400/ 400 C/ h F400 JAF-KI-400-/4-R JAF-KI-400-/4-R-00/ 8400 / 3~ / / / 9.3 JAF-KI-400-/4-R-300/ 400 JAF-KI-400-/4-R-400/ 400 C/ h F400 JAF-KI-450--U JAF-KI-450--U-00/ 00 C/ h F00 3~ JAF-KI-450--U-300/ 300 C/ h F300 JAF-KI-450--U-450/ 400 C/ h F400 JAF-KI-450M--U JAF-KI-450M--U-00/ 00 C/ h F00 3~ JAF-KI-450M--U-300/ 300 C/ h F300 JAF-KI-450M--U-400/ 400 C/ h F400 JAF-KI-450S--U JAF-KI-450S--U-00/ 00 C/ h F00 3~ JAF-KI-450S--U-300/ 300 C/ h F300 JAF-KI-450S--U-400/ 400 C/ h F400 JAF-KI-450-/4-U JAF-KI-450-/4-U-00/ 0700 / 3~ / / / 9.3 JAF-KI-450-/4-U-300/ 5300 JAF-KI-450-/4-U-400/ 400 C/ h F400 JAF-KI-450M-/4-U JAF-KI-450M-/4-U-00/ 900 / 3~ / / 0.8 / 0.3 JAF-KI-450M-/4-U-300/ 5900 JAF-KI-450M-/4-U-400/ 400 C/ h F400 JAF-KI-450S-/4-U JAF-KI-450S-/4-U-00/ 800 / 3~ / / 6.4 /. JAF-KI-450S-/4-U-300/ 6400 JAF-KI-450S-/4-U-400/ 400 C/ h F400 JAF-KI-450--R JAF-KI-450--R-00/ 00 C/ h F00 3~ JAF-KI-450--R-300/ 300 C/ h F300 JAF-KI-450--R-450/ 400 C/ h F400 JAF-KI-450M--R JAF-KI-450M--R-00/ 00 C/ h F00 3~ JAF-KI-450M--R-300/ 300 C/ h F300 JAF-KI-450M--R-400/ 400 C/ h F400 JAF-KI-450S--R JAF-KI-450S--R-00/ 00 C/ h F00 3~ JAF-KI-450S--R-300/ 300 C/ h F300 JAF-KI-450S--R-400/ 400 C/ h F400 JAF-KI-450-/4-R JAF-KI-450-/4-R-00/ 000 / 3~ / / / 8.8 JAF-KI-450-/4-R-300/ 5000 JAF-KI-450-/4-R-400/ 400 C/ h F400 8 VENTS. Smoke extraction ventilation for parking premises 03-08
8 Ø [mm] Air flow direction Number of speeds 450 Reversible Uni-directional Reversible Uni-directional Reversible Uni-directional Reversible JAF-KI-450M-/4-R Unit voltage [V] Frequence [Hz] Power [kw] Max. air Air speed capacity Fan pull [N] [m/s] [m 3 /h] RPM Operating temperature [ C] Fire resistance JAF-KI-450M-/4-R-00/ 500 / 3~ / / 0 0 / 0 JAF-KI-450M-/4-R-300/ 5700 JAF-KI-450M-/4-R-400/ 400 C/ h F400 JAF-KI-450S-/4-R JAF-KI-450S-/4-R-00/ 00 / 3~ / / 4.3 / 0.4 JAF-KI-450S-/4-R-300/ 6000 JAF-KI-450S-/4-R-400/ 400 C/ h F400 JAF-KI-500-/4-U JAF-KI-500-/4-U-00/ 6600 / 3~ / / /.6 JAF-KI-500-/4-U-300/ 800 JAF-KI-500-/4-U-400/ 400 C/ h F400 JAF-KI-500M-/4-U JAF-KI-500M-/4-U-00/ 8800 / 3~ /. 83 / / 3.3 JAF-KI-500M-/4-U-300/ 9400 JAF-KI-500M-/4-U-400/ 400 C/ h F400 JAF-KI-500-/4-R JAF-KI-500-/4-R-00/ 400 / 3~ / / 5 0 / 0 JAF-KI-500-/4-R-300/ 7000 JAF-KI-500-/4-R-400/ 400 C/ h F400 JAF-KI-500M-/4-R JAF-KI-500M-/4-R-00/ 6000 / 3~ /. 3 / 33.7 /.3 JAF-KI-500M-/4-R-300/ 8000 JAF-KI-500M-/4-R-400/ 400 C/ h F400 JAF-KI-560-/4-U JAF-KI-560-/4-U-00/ 400 / 3~ /. 85 / / JAF-KI-560-/4-U-300/ 0600 JAF-KI-560-/4-U-400/ 400 C/ h F400 JAF-KI-560M-/4-U JAF-KI-560M-/4-U-00/ 4500 / 3~ / 45 / / 3.8 JAF-KI-560M-/4-U-300/ 00 JAF-KI-560M-/4-U-400/ 400 C/ h F400 JAF-KI-560-/4-R JAF-KI-560-/4-R-00/ 800 / 3~ /. 34 / / 0. JAF-KI-560-/4-R-300/ 9000 JAF-KI-560-/4-R-400/ 400 C/ h F400 JAF-KI-560M-/4-R JAF-KI-560M-/4-R-00/ 000 / 3~ /.5 77 / /.9 JAF-KI-560M-/4-R-300/ 0500 JAF-KI-560M-/4-R-400/ 400 C/ h F400 JAF-KI-630-/4-U JAF-KI-630-/4-U-00/ / 3~ / 3 98 / / 3.4 JAF-KI-630-/4-U-300/ 5000 JAF-KI-630-/4-U-400/ 400 C/ h F400 JAF-KI-630M-/4-U JAF-KI-630M-/4-U-00/ / 3~ / 4 44 / / 5.8 JAF-KI-630M-/4-U-300/ 7700 JAF-KI-630M-/4-U-400/ 400 C/ h F400 JAF-KI-630-/4-R JAF-KI-630-/4-R-00/ / 3~ / / / 3.4 JAF-KI-630-/4-R-300/ 5000 JAF-KI-630-/4-R-400/ 400 C/ h F400 JAF-KI-630M-/4-R JAF-KI-630M-/4-R-00/ / 3~ / / / 4.3 JAF-KI-630M-/4-R-300/ 6000 JAF-KI-630M-/4-R-400/ 400 C/ h F400 VENTS. Smoke extraction ventilation for parking premises
9 IMPULSE CENTRIFUGAL FANS ICF SERIES Application Impulse centrifugal fans ICF are designed for general purpose ventilation of underground and semiopened parkings, smoke extraction in case of fire as a part of smoke extract system. The fans generate a high-speed and high-pressure directed air jet. Motor Single- or double-speed 4-, 6- or 8-pole asynchronous motors. Motor ingress protection rating is IP55. Impeller The impeller with backward curved steel blades. Impulse centrifugal fans with fire resistance limit 00 C/ h, 300 C/ h and 400 C/ h for ventilation of underground parkings. Compactness. Power. Efficiency. Modifications Single-speed Double-speed Design ICF casing is made of polymer coated steel. Due to low height of the casing the fan is recommended for use in low-ceilinged room. The protecting grille on the intake side prevents ingress of foreign objects into the fan. Deflector plates on the exhaust side of the fan ensure correct air flow distribution. Mounting ICF fans are designed for ceiling mounting and fixation by means of the supplied fixing brackets. Power is supplied through the internal terminal box. The fan wiring and mounting must be made according to the instructions and the wirind diagram shown in the terminal box. A Dimensions [mm] А В С Н К Weight [kg] K ICF-50N H C B ICF-85N ICF-00N Fan pull [N] Pole number Climatic category Fire resistance limit/hrs ICF (impulsion centrifugal fan) 50 N 85 N 00 N 4 4/6 (applicable for double-speed models) 4/8 (applicable for double-speed models) U: moderate climate ( C) HL: cold climate ( C) UHL: moderate and cold climate ( C) T: tropical climate ( C) M: maritime moderately cold climate ( C) O: general climatic modification (except maritime climate) ( C) OM: general maritime climatic modification ( C) V: universal climatic modification ( C) no number: max. +55 C 00/: 00 C/ hrs. 300/: 300 C/ hrs. 400/: 400 C/ hrs. 0 VENTS. Smoke extraction ventilation for parking premises 03-08
10 Technical data Number of speeds Unit Frequence voltage [V] [Hz] Max. air capacity [m 3 /h] Power [kw] Fan pull [N] Air speed [m/s] RPM Operating temperature [ C]* Fire resistance 50N, SINGLE-SPEED ICF-50N-4 ICF-50N-4-00/ 00 C/ h F00 3~ ICF-50N-4-300/ 300 C/ h F300 ICF-50N-4-400/ 400 C/ h F400 Weight [kg] 96 50N, DOUBLE-SPEED ICF-50N-4/6 ICF-50N-4/6-00/ 00 C/ h F00 3~ / / / / / 000 ICF-50N-4/6-300/ 300 C/ h F300 ICF-50N-4/6-400/ 400 C/ h F400 ICF-50N-4/8 ICF-50N-4/8-00/ 00 C/ h F00 3~ / / / / / 750 ICF-50N-4/8-300/ 300 C/ h F300 ICF-50N-4/8-400/ 400 C/ h F N, SINGLE-SPEED ICF-85N-4 ICF-85N-4-00/ 00 C/ h F00 3~ ICF-85N-4-300/ 300 C/ h F300 ICF-85N-4-400/ 400 C/ h F N, DOUBLE-SPEED ICF-85N-4/6 ICF-85N-4/6-00/ 00 C/ h F00 3~ / / / 8.3 / / 000 ICF-85N-4/6-300/ 300 C/ h F300 ICF-85N-4/6-400/ 400 C/ h F400 ICF-85N-4/8 ICF-85N-4/8-00/ 00 C/ h F00 3~ / 450. / / 0.3 / / 750 ICF-85N-4/8-300/ 300 C/ h F300 ICF-85N-4/8-400/ 400 C/ h F N, SINGLE-SPEED ICF-00N-4 ICF-00N-4-00/ 00 C/ h F00 3~ ICF-00N-4-300/ 300 C/ h F300 ICF-00N-4-400/ 400 C/ h F N, DOUBLE-SPEED ICF-00N-4/8 ICF-00N-4/8-00/ 00 C/ h F00 3~ / / / / / 750 ICF-00N-4/8-300/ 300 C/ h F ICF-00N-4/8-400/ 400 C/ h F400 VENTS. Smoke extraction ventilation for parking premises 03-08
11 VENTILATION OF UNDERROOF PARKING VENTS. Smoke extraction ventilation for parking premises 03-08
12 VENTS. Smoke extraction ventilation for parking premises
13 SMOKE EXTRAXTION AND VENTILATION The catalogue information is for reference only. VENTS reserves the rights to modify any of its products features, designs, components and specifications at any time and without notice to maintain the development and quality of manufactured goods. 03/08 ventilation.system
VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS
SOUND-INSULATED FANS Series Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7 m 3 /h Purpose KSB fan design allows to use them in supply and exhaust ventilation systems
More informationSeries VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h
SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.
More informationSeries VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.
AXIAL FANS Series Series K Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 11900 m 3 /h for wall mounting. Low pressure axial fans in the steel casing with the air
More informationSeries VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting
AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 122 m 3 /h for wall mounting Low pressure axial fans in the steel casing
More informationFIRE SAFETY PRODUCTS SMOKE EXTRACT FANS FIRE AND SMOKE DAMPERS
Smoke Extraction and Ventilation FIRE SAFETY PRODUCTS SMOKE EXTRACT FANS FIRE AND SMOKE DAMPERS VENTS reserves the rights to modify any of its products features, designs, components and specifications
More informationSeries VENTS OVК. Axial fans of low pressure in steel case with the efficiency. wall-mounted assembly.
AXIAL FAN Series Series К Series Axial fans of low pressure in steel case with the efficiency up to 11900 m 3 /h for a wall-mounted assembly Axial fans of low pressure in steel case with the efficiency
More informationNovenco Tunnel Fans. Novax October 2007
Novenco Tunnel Fans Novax October 2007 Product facts Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC and AUR) and
More informationSMOKEX EMERGENCY SMOKE EXTRACT AIR VENT T E C H N O L O G Y. C E certified to Class F300/120 or F400
EMERGENCY SMOKE EXTRACT AIR VENT T E C H N O L O G Y C E certified to Class F300/120 or F400 Emergency Smoke Extract dex LCA-JT/HT SMOKEX Axial impulse fans for car park ventilation F300/120 - F400 Pages
More informationSeries VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.
AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 11900 m 3 /h for wall mounting. Low pressure axial fans in the steel casing
More informationAxial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.
xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationDVAX-ARS. Roof-mounted unit for mechanical smoke extract
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit
More informationAC Commercial Fans Edition. ErP ready
AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application
More informationHIGH-POWERED VENTILATORS
HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series
More informationCRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS
ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire
More informationAXIAL FANS Axis / Tubo OPERATION MANUAL
TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements
More informationSabre Plate Mounted Sickle Fans (VSP)
Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation
More informationIn-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.
In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V
More informationSquare Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.
Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable
More informationShort casing. Long casing (L version) Commercial premises
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART COMPACT A 204 PERFORMANCE CHART COMPACT B 205
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART A 204 PERFORMANCE CHART B 205 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEALS 301
More informationUSER S MANUAL VENTS OV/ OVK/ OV1/ OV1 R/ OVK1/ VKF/ VKOM / OVP
USER S MANUAL Industrial electric axial fans VENTS OV/ OVK/ OV1/ OV1 R/ OVK1/ / VKOM / OVP 2 CONTENTS Safety requirements 3 Introduction 5 Purpose 5 Delivery set 5 Designation key 5 Technical data 6 Design
More information400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity
400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,
More informationCYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS
- ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate
More informationDuct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ
Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3
More informationROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE
ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4
More informationIN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems
IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range
More informationVENTS ТТ. Series. In-line mixed-flow fans in plastic casing with the air capacity up to 2350 m 3 /h. FANS FOR ROUND DUCTS
FANS FOR ROUND DUCTS Series In-line mixed-flow fans in plastic casing with the air capacity up to 2350 m 3 /h. Applications VENTS TT series full-featured fans combine manifold possibilities and high features
More informationMAJAX-2 GENERAL SPECIFICATION
MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed
More informationIN-LINE DUCT FANS MIXVENT-TD Fan Systems
IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL
More informationDynamically-balanced impellers with extremely robust cores CMP T 5.5
Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.
More informationTHT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G
THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.
More informationSentinel D-Box Twin Fan
Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc
More informationAir Flow Solutions. Commercial Fans Offices, retail, leisure, education
Air Flow Solutions ommercial Fans Offices, retail, leisure, education ommercial Fans Why Ventilate? AIRF'S extensive range of extract fans are not just for domestic dwellings. Their outstanding performance,
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATION 202 PERFORMANCE CURVE 40/86 203 PERFORMANCE CURVE 40/106 204 PERFORMANCE CURVE 40/126 205 PERFORMANCE CURVE 40/156
More informationCYLINDRICAL CASED AXIAL FLOW FANS
- Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate
More informationVKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.
Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,
More informationCAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power
CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators
More information- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE DWC PERFORMANCE CURVE DWC
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 300 203 PERFORMANCE CURVE 500 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL
More informationPowerful centrifugal fans for universal use: The product ranges TEM and REM
Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which
More informationPerformance. Sound Levels. Impellers. Motors. Accessories
EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation
More informationIN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE
IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE CIL - Centrifugal In-Line Fans SBAF - Slimbox Acoustic Fans ACF - Acoustic Cabinet Fans - Direct Drive ACFS - Super-Silent Acoustic Cabinet Fans
More informationAerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices
Aerofoil Ventilation Fans Quality & Performance at Affordable Prices GENERAL FEATURES, located in Chennai strives to deliver quality products at affordable costs to all its customers. Our company s vision
More informationCSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller
CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys
More informationPLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance
A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with
More informationHIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION
HT Er 1253 CENTRFUGAL N-LNE FANS ALCATON Centrifugal in-line fans suitable to extract air in commercial and industrial buildings such as toilets, bathrooms, sports halls, warehouses, schools, offices,
More informationsupplied in Form (B) configuration. Airflow over Impeller- Motor.
CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,
More informationDuctable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03
Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 3 ( 3-4-5-6 IMPELLERS ) 205 PERFORMANCE CURVE 3 ( 7-8-9 IMPELLERS
More informationQuestion: Automobiles. Observations About Automobiles. Heat Engines. Heat Pumps. Question:
Automobiles 1 Automobiles 2 Question: Automobiles A car burns gasoline to obtain energy but allows some heat to escape into the air. Could a mechanically perfect car avoid releasing heat altogether? Automobiles
More informationBSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS
SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS BSB 03.06-01 BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS Description Construction Fans are not
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 PERFORMANCE CHART A (up to 0.6 kw) 203 PERFORMANCE CHART A (from 0.75 kw up to 1.1 kw) 204 PERFORMANCE CHART A (1.3 kw) 205 PERFORMANCE
More informationWALL VENTILATION GRILLES CBP
WALL VENTILATION GRILLES CBP 01.10-01 CBP WALL VENTILATION GRILLES Description Designed for ventilation and air-conditioning installations, where control of air flow and direction of the air is required.
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationMedium Pressure Centrifugal Fans
Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock
More informationMULTIGO. EBARA Pumps Europe S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 40 203 PERFORMANCE CURVES 80 204 - CONSTRUCTIONS SECTIONAL VIEW
More informationTube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.
Tube Fans - ROPERA Range Features 1 mm to 355 mm diameter Air flow 234 m 3 /h (.65 m 3 /s) Static pressures up to 92 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection
More informationTGT Series Adjustable Pitch Fans
CYLINDRICAL CASED AXIAL FLOW FANS Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot dipped
More informationCMA-B-C-D. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE 201 SELECTION CHART 202 TYPE KEY 203 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE CMA 204 PERFORMANCE CURVE CMB 205 PERFORMANCE CURVE CMC 206 PERFORMANCE
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS 300 SECTIONAL VIEW
More information3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page - SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 PERFORMANCE CURVE 32-125 5 PERFORMANCE CURVE 32-6 PERFORMANCE CURVE 32-0 7 PERFORMANCE CURVE 40-125 8 PERFORMANCE
More informationHIGH TEMPERATURE TWIN SQUIF FANS
HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing
More informationMODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN
MODEL FEATURES Exhaust air up to 2,630 CFM with static pressure capabilities to 1 w.g. Mixed flow impeller for excellent air flow to pressure performance ratio Direct connection, two-speed motor Ideal
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART 40 203 PERFORMANCE CHART 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW 301
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationCHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT
BACKWARD CURVED CENTRIFUGAL FANS Series The CHVB-CHVT range is suitable for many general ventilation applications where high system resistances are present; i.e. systems with filters, dampers etc. Range
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 BEARINGS 303
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.50 203 PERFORMANCE CURVE 0.80 204 PERFORMANCE CURVE 1.00 205 PERFORMANCE
More information2CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS 300 SECTIONAL VIEW
More informationAxial fans. What s more, non-stock models are normally available within two weeks.
Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive
More informationCENTRIFUGAL DIRECT DRIVE FANS CMT-CMB
CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The
More informationTGT Series Adjustable Pitch Fans
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot
More informationAC axial fans, AC diagonal fans
fans, C diagonal fans Technology ccessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans series fans fans Ø 130 - Ø 250 14 C diagonal fans Ø 208 20 13 Contacts fans Ø 130
More informationThe Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS and WEIGHT 400 PUMP 400 PACKING 401
CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 076 203 PERFORMANCE CURVES 106 204 - CONSTRUCTIONS 300 SECTIONAL
More informationAXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure
Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation
More informationPage - DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX 5/10/ PUMP TABLE MATRIX 5/10/ PACKING 403
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 3 ( 2-3 IMPELLERS ) 204 PERFORMANCE CURVE 3 ( 4-5-6 IMPELLERS )
More informationHXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance
PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel
More informationPage - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE BEST 2 203 PERFORMANCE CURVE BEST 3 203 PERFORMANCE CURVE BEST 4 203 PERFORMANCE CURVE BEST
More informationAGA-AGC. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE AGA 0.60 203 PERFORMANCE CURVE AGA 0.75 204 PERFORMANCE CURVE AGA 1.00 205 PERFORMANCE CURVE
More informationSquare Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.
Square Duct Fans - ESTOC TARGE Range Features Sizes from 55 to 6 mm diameter Air flow 21, m /h (5.8 m /s) Static pressures up to 145 Pa Maximum temperature up to 11 C Controllable external rotor motors
More information(%$5$ PUMPS EUROPE S.p.A. &(175,)8*$/38036':2. &217(176 50Hz
&(175,)8*$/38036':2 &217(176 50Hz Page 63(&,),&$7,216 200 SELECTION CHART 201 PERFORMANCE CHART 150 202 PERFORMANCE CHART 200 203 PERFORMANCE CHART 300 204 PERFORMANCE CHART 400 205 &216758&7,216 300 SECTIONAL
More informationCMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C
BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured
More informationCM5-5 A-R-A-E-AVBE F-A-A-N
GRUNDFOS DATA BOOKLET CM5-5 A-R-A-E-AVBE F-A-A-N Grundfos Pump 9686818 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/9686818/cm5-5-a-r-a-e-avbe.html
More informationFuel Wize works with engine oil as well.
Fuel Wize works with engine oil as well. It first functions as a soap/solvent which cleans the walls of the cylinder while removing many of impurities and residues in the oil. Second, Fuel Wize actually
More informationVent-Axia Sabre Sickle Roof Fans (VSR)
Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,
More informationSuitable For: Bathroom Living Area Whole House Ventilation Duct Boosting Hydroponic Growing General Ventilation
TT inline mixed type fans combine wide capabilities and excellent features of axial and centrifugal fans. The unique motor and impeller combination enables the TT fans to deliver high performance with
More informationMODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN
MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN MODEL FEATURES Exhaust air up to 2,630 CFM with static pressure capabilities to 1 w.g. Mixed flow impeller for excellent air flow to pressure performance ratio
More informationDTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan
Product information - Version 3 DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Overskrift placering Table of contents Choice of motor... 4 DTV roof fans... 5 - Technical specifications
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.75 203 PERFORMANCE CURVE 1.00 204 - CONSTRUCTIONS 300 SECTIONAL VIEW
More informationEFFECT OF EGR AND CYCLONIC SEPARATOR ON EMISSIONS IN DI DIESEL ENGINES
Proceedings of the International Conference on Mechanical Engineering 27 (ICME27) 29-31 December 27, Dhaka, Bangladesh ICME7-TH-9 EFFECT OF EGR AND CYCLONIC SEPARATOR ON EMISSIONS IN DI DIESEL ENGINES
More informationWINDER. Impellers with higher efficiency and less sound level
WINDER Impellers with higher efficiency and less sound level Winder Solutions The last new generation impeller With the Serrated Novovent Concept (S.N.C.), NOVOVENT, S.A. has developed a new blades generation.
More informationPage - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 203 LPC4 32 205 LPC4 40 206 LPC4 50 211 LPC4 65 215 LPC4 80 219 LPC4 100 222 LPC4 125 225 LPC4 150 226 - CONSTRUCTIONS
More informationKAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels
KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to
More informationF a n t y p e s J K K - J K K
F a n t y p e s J K - 3 K - J K - 7 5 K Section: 2 Page: 1/6 Revised: 1..25 The indirect drive centrifugal fan types JK-3K - JK-75K are designed for material handling. M N Equipped with self-cleaning impellers
More informationTwin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range
Twin and Single Inline Fans Offers a range of flexible installation and application options, including auto-changeover on the Twin range 2 Version 3.1 Breathing Buildings Inline Box Fans Demand Control
More information- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO
CONTENTS Page - CONTENTS CONTENTS 100 - SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 40 202 PERFORMANCE CHART 80 203 - CONSTRUCTIONS CONSTRUCTIONS 300 CONSTRUCTIONS 301 CONSTRUCTIONS
More informationCVHT Series - F rated cabinet fans
N 50-55 1/1/08 19:26 Página 50 BLT DRIVN BINT NS Series - 00 120 rated cabinet fans NW pproved to N12101- standard Range of belt drive cabinet fans designed for smoke extraction in fire conditions and
More information