Directional Control Valves. Features. Application. Operation

Size: px
Start display at page:

Download "Directional Control Valves. Features. Application. Operation"

Transcription

1 Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold mounted. hese valves conform to NF s D05H, CEO 5 and can also be manufactured to an NF DO5HE, CEO 5H configuration. Operation Series D31 directional valves consist of a 5-chamber style main body, a case hardened sliding spool, and a pilot valve or pilot operators (hydraulic or pneumatic). Series D31 Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 175 LM (45 GM) depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish. oth NF and CEO mounting styles available. D31*W Solenoid Operated lug-in Conduit ox D31*L Lever Operated D3* Oil ilot Operated D31* ir ilot Operated 78 Elyria, Ohio, US

2 echnical Information Series D31 General Series D31 directional control valves are 5-chamber, pilot operated, solenoid controlled valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Specifications Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H Max. Operating 345 ar (5000 SI) Standard ressure 207 ar (3000 SI) 10 Watt Max. ank Line ressure CS 207 ar (3000 SI) Internal Drain Model: 103 ar (1500 SI) C Std. 207 ar (3000 SI) DC Std./C Opt. External Drain Model: 207 ar (3000 SI) CS 103 ar (1500 SI) Max. Drain 103 ar (1500 SI) C only ressure 207 ar (3000 SI) DC Std./C Opt. CS 103 ar (1500 SI) Min. ilot ressure 6.9 ar (100 SI) Max. ilot ressure 345 ar (5000 SI) Standard Nominal Flow Maximum Flow CS 207 ar (3000 SI) 76 Liters/Min (20 GM) See Switching Limit Charts Response ime Response time (milliseconds) at 345 ar (5000 SI) is 76 LM (20 GM) Solenoid ilot ype ressure ull-in Drop-Out DC C Switching Limit Charts SI ar For Styles F and M external drain only (For internal drain see note below) 6.9 ar (100 SI) pilot 2,7 (14) 1, 3, (15), 4, 5 (16), 6, 11 Supply ressure with 150 SI ilot 0 LM GM Flow Note: Internal Drain 1, 4 spools 113 LM (30 GM) max., 2, 9 & 14 spools per curve ll others 95 LM (25 GM) max. 79 Elyria, Ohio, US

3 Ordering Information Series D31 D Directional Control Valve asic Valve ctuator Spool Style ilot Supply Seal Solenoid and Drain Voltage 31D NF D05HE, CEO 5H, DIN NG10, D03 ilot, ISO ort 31V NF D05H, CEO 5, D03 ilot, NF ort Symbol Symbol * ** 008* ** W# Solenoid, Wet in, Screw-in HW# Reversed Wiring # Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D31VHW***. * 008 & 020 spools have closed crossover. ** 009 & 030 spools have open crossover. N V Nitrile Fluorocarbon ** D G J K N*** *** Q** QD R U 24/50 VC 120 VDC 198 VDC 24 VDC 12 VDC 220/50 VC 110/50 VC 100/60 VC 100 VC/60 Hz 100 VC/50 Hz 24/60 VC 240/60-220/50 VC 98 VDC Y 120/60-110/50 VC Z 250 VDC ** High watt only. *** Explosion proof only. vailable in DIN only. Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. D* Double solenoid, 2 position, detent. E Single solenoid, 2 position, spring centered. to and to when energized. F Single solenoid, 2 position, spring offset, energized to center. Spacer on side. to and to in offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K 1* Internal ilot, External Drain 2* External ilot, External Drain 4# Internal ilot, Internal Drain 5 External ilot, Internal Drain * F and M style available only with external drain. # Not available with 002, 007, 008, 009 or 014 spools. Single solenoid, 2 position, spring centered. to and to when energized. M Single solenoid, 2 position, spring offset, energized to center. Spacer on side. to and to in offset position. * 020 and 030 spools only. High watt only. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. b b b b b a a a a a 80 Elyria, Ohio, US

4 Ordering Information Series D31 Valve Weight: Double Solenoid 5.4 kg (12.0 lbs.) Seal Kit: Nitrile SKD31VWN91 Fluorocarbon SKD31VWV91 Solenoid Connection C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Coil Options Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. ube Options Manual Override Options Omit Standard Extended with oot None DC or C rectified only. Manual Override options not available with Explosion roof. Omit Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Electrical Options Mounting olt Kits Shift pprovals Response and Indication Valve Variations See next page for Valve Variations Design Series NOE: Not required when ordering. Omit Standard Valve 3* CS US 4*# CS pproved * Not available with C high pressure tube. # Valve is derated with this option., C, H styles only. J, K, Y, U voltages only with C, G, W solenoid connections only. Conforms to UL429. Omit Standard Response, No Switch I3 Monitor Switch, & ort End I6 Monitor Switch, & ort Start Note: Not CE or CS approved. Spools 008, 009, 081 and 082 not available. Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. UNC olt Kits for use with D31*W & Sandwich Valves Number of Sandwich 2.00 (50mm) thickness D31*W Standard: K98 K141 K142 K Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm NOE: ll bolts are SE grade 8. Standard bolts are 1/4-20 UNC thread. Metric bolts are M6-1.0 thread. orque to 16 Nm (12 ft-lbs). old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 81 Elyria, Ohio, US

5 Ordering Information Series D31 Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with lug) 7** Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 20 Fast Response 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1 ainted ody 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights, Mini Manaplug, ilot Choke Meter Out 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. 82 Elyria, Ohio, US

6 echnical Information Series D31 D31 Series ressure Drop vs. Flow he chart below provides the flow vs. pressure drop curve reference for the D31 Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D31 with a number 1 spool. o the right of spool number 1, locate the number 3 in the - column, and 2 in the - column. Using the graph at the bottom, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. Note: ressure drops should be checked for all flow paths, especially when using non-symmetrical spools (003, 005, 007, 014, 015 and 016) and unbalanced actuators. D31 ressure Drop Reference Chart Curve Number Spool Shifted Center Condition No (-) (-) (-) (-) (-) (-) (-) erformance Curves Viscosity Correction Factor Viscosity (SSU) % of Δ (pprox.) Curves were generated using 110 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. 83 Elyria, Ohio, US

7 echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D31 Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms 84 Elyria, Ohio, US

8 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Conduit ox, Double C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit ox and Stroke djust, Double C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 85 Elyria, Ohio, US

9 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Conduit ox and ilot Choke Control, Double C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit ox, Single C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 86 Elyria, Ohio, US

10 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Hirschmann and Stroke djust, Double DC Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Hirschmann and ilot Choke Control, Double DC Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 87 Elyria, Ohio, US

11 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Explosion roof U.L. and C.S.. pproved, Double Solenoid hase Out 88 Elyria, Ohio, US

12 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Explosion roof, EX d IIC EX/CS Single Solenoid Explosion roof, EEXD EX, Single Solenoid (5.14) (6.40) M20x1.5-6H hd. Ground Stud with Lock Washer 74.7 (2.94) 69.9 (2.75) 34.9 (1.38) (8.46) (7.25) 73.5 (2.90) (4.96) 83.0 (3.27) 62.0 (2.44) (8.84) 36.0 (1.42) 35.0 (1.38) 70.0 (2.76) 89 Elyria, Ohio, US

13 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid lug-in Conduit ox, Single DC Solenoid 90 Elyria, Ohio, US

14 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid with Variation I3 (Monitor Switch) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve exists when both coils are de-energized, or during a complete shift, as the spool passes through center. Monitor Switch (Variation I3 and I6) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data in 1 and in 3 have outputs equal to the input. When the monitor switch has the output to in 1, in 3 will have an output of zero, and vice-versa. When the valve is switched, in 1 and in 3 will switch outputs. IN 2 Input VDC osition Control Switch Sensor / Driver Circuitry Load 0.2 Max IN 1 IN 3 Outputs 91 Elyria, Ohio, US

15 ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D31 Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

16 echnical Information Series D31NW General Series D31NW valves are piloted by a D1VW valve. he valves can be ordered with position control. he minimum pilot pressure must be ensured for all operating conditions of the directional valve. dditionally spools with a to connection in the deenergized position need an external pressure supply (external inlet) or an integral check valve. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Dimensions Inch equivalents for millimeter dimensions are shown in (**) * lease add for each sandwich plate +40mm (1.58") (pressure reducing valve, pilot choke valve meter-in/-out). Surface Finish Seal K385 4x M6x40 DIN Nm (9.7 lb.-ft.) Nitrile: SK-D31NW-N-91 Fluorocarbon: SK-D31NW-V-91 he space necessary to remove the plug per DIN 43650, design type F is at least 15 mm. he torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. 93 Elyria, Ohio, US

17 Ordering Information Series D31NW D Directional Control Valve 31N asic Valve W ctuator Solenoid Wet in Spool Style ilot Supply and Drain NF D05HE CEO 5H DIN NG10 D03 ilot, High flow 1 Internal ilot External Drain 2 External ilot External Drain 4* Internal ilot Internal Drain 5 External ilot Internal Drain * Not available with 002, 007, 009, 014, 030, 031, 032 spools. 3-osition Spools Spool ype a 0 b C E F K 3-osition Spools ll 3-osition Spools 3 positions. Spring offset in position 0. Operated in position a or b. Standard Spool ype 009 Operated in position a. Spring offset in position b. Operated in position b. Operated in position b. Spring offset in position a. Operated in position a. 2 positions. Spring offset in position 0. 2 positions. Operated in position 0. 2 positions. Spring offset in position M Spring offset in position a. Spring offset in position b. 2 positions. Operated in position R S No center in offset position. No center in offset position. No center in offset position. No center in offset position. 2 positions, detent. Operated in position 0 or b. 2 positions, detent. Operated in position 0 or a. No center in offset position. 2-osition Spools Spool ype a b D 2-osition Spools Spool osition Spring offset in position b. Operated in position a. Detent, operated in position a or b. No center or offset position. Weight: Single Solenoid: 7.6 kg (16.8 lbs.) Double Solenoid: 8.1 kg (17.9 lbs.) H Spring offset in position a. Operated in position b. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 94 Elyria, Ohio, US

18 Ordering Information Series D31NW Seal N Nitrile V Fluorocarbon Solenoid Voltage Solenoid Connection Coil Options ube Options Manual Override Options Electrical Options Shift Response and Indication Valve Variations See next page Design Series NOE: Not required when ordering. * 24/50 VC D 120 VDC G 198 VDC J 24 VDC K 12 VDC N** 220/50 VC Q* 100/60 VC QD 100 VC/60 HZ 100 VC/50 HZ R 24/60 VC U 240/60-220/50 VC 98 VDC Y 120/60-110/50 VC Z 250 VDC * High Watt Coil only. ** Explosion roof only. vailable in DIN only. C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Omit Standard Extended with oot None DC or C Rectified only. Manual Override options not available with Explosion roof. Omit Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Omit I3N Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. Standard Response, No Switch Monitor Switch, & ort End I6N Monitor Switch, & ort Start Note: Not CE or CS approved. vailable in C style with 001, 003, , 021, and 022 spools only. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 95 Elyria, Ohio, US

19 Ordering Information Series D31NW Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with lug) 7** Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights, Mini Manaplug, ilot Choke Meter Out 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. 96 Elyria, Ohio, US

20 echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D31NW Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms 97 Elyria, Ohio, US

21 Specifications Series D31NW General Design Directional Spool Valve ctuation Solenoid Size NG10 Mounting Interface DIN / ISO 4401 / NF D05 / CEO R 121-H Mounting osition Unrestricted, preferably horizontal mbient emperature [ C] [ C] MF D Value [years] ; (-13 F F) (without inductive position control) ; (+32 F F) (with inductive position control) Hydraulic Maximum Operating ressure ilot drain internal:,,, X 315 ar (4568 SI);, Y 140 ar (2030 SI) ilot drain external:,,,, X 315 ar (4568 SI); Y 140 ar (2030 SI) Fluid Hydraulic oil in accordance with DIN / Fluid emperature [ C] (-13 F F) Viscosity ermitted [cst]/[mm²/s] ( SSU) Recommended [cst]/[mm²/s] ( SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Flow Maximum 170 LM (45 GM) Leakage at 350 ar (per flow path) [ml/min] ( GM) (depending on spool) Minimum ilot Supply ressure 7 ar (102 SI) Static / Dynamic Step Response at 85% Energized De-energized DC Solenoids ilot ressure 50 ar & 100 ar [ms] ar & 350 ar [ms] C Solenoids ilot ressure 50, 100, 250 & 350 ar [ms] 30 / Elyria, Ohio, US

22 Electrical Specifications Series D31NW osition Control M12x1 rotection Class I 65 in accordance with EN (plugged and mounted) mbient emperature [ C] ; (+32 F F) Supply Voltage / Ripple [V] ±10% Current Consumption without Load [m] 30 Max. Output Current per Channel, Ohmic [m] 400 Min. Output Load per Channel, Ohmic [kohm] 100 Max. Output Drop at 0.2 [V] 1.1 Max. Output Drop at 0.4 [V] 1.6 EMC EN / EN Max. olerance mbient Field Strength [/m] <1200 Min. Distance to Next C Solenoid [m] >0.1 Interface M12x1 per IEC Wiring Minimum [mm²] 5 x 0.25 brad shield recommended Wiring Length Maximum [m] 50 (164 ft.) recommended M12 in ssignment 1 + Supply V 2 Out : normally closed 3 0V 4 Out : normally open 5 Earth ground Definitions Start position monitored: he valve is de-energized. he inductive switch gives a signal at the moment (below 15% spool stroke) when the spool leaves the spring offset position. End position monitored: he inductive switch gives a signal before the end position is reached. (above 85% spool stroke). Delivery includes plug M12 x 1 (part no.: ). 99 Elyria, Ohio, US

23 echnical Information Series D31NW erformance Curves he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. Spool Curve Number ll characteristic curves measured with HL46 at 50 C (122 F). Integral Check Valve in the port Mounting an integral check valve in the port is necessary to build up pilot pressure for valves with to connection and internal pilot oil supply. he pressure difference at the integral check valve (see performance curves) is to be added to all flow curves of the -port of the main valve. ilot Oil Inlet (Supply) and Outlet (Drain) ll orifice sizes for standard valves 100 Elyria, Ohio, US

24 ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D31NW Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

25 echnical Information Series D31* General Series D31* directional control valves are 5-chamber, air pilot operated valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Specifications Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H ressure Drop Chart Max. Operating ressure Max. ank Line ressure 345 ar (5000 SI) Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) Max. Drain ressure 34 ar (500 SI) Maximum Flow See Switching Limit Charts ilot ressure ir Min: 3.4 ar (50 SI) ir Max: 10.2 ar (150 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) VISCOSIY CORRECION FCOR Viscosity (SSU) % of Δ (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. D31V ressure Drop Reference Chart -- Curve Number Spool Shifted Center Condition No (-) (-) (-) (-) (-) (-) (-) D31V ressure Drop vs. Flow he chart to the left provides the flow vs. pressure drop curve reference for the D31V Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D31V with a number 001 spool. o the right of spool number 001, locate the number 3 in the - column, and 2 in the - column. Using the top graph, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. 102 Elyria, Ohio, US

26 echnical Information Series D31* Ordering Information D Directional Control Valve asic Valve 31D NF D05HE, CEO 5H (ISO) 31V NF D05H, CEO 5 Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #008 and #009 spools. See installation information for details. Valve Weight: Double Operator 5.7 kg (12.7 lbs.) Standard olt Kit: K98 Metric olt Kit: KM98 ir Operated ilot Symbol * * 008 and 020 spools have closed crossover. * 009 and 030 spools have open crossover. Spool Style ilot Supply Seal Valve and Drain Variations Single operator, 2 position, spring offset. to and to in offset position. C Double operator, 3 position, spring centered. D Double operator, 2 position, detent. E N Nitrile Omit Standard V Fluorocarbon 7 ilot Choke - Meter Out 8 Stroke dj. End 9 Stroke dj. End 1 Int. pilot/ext. drain 60 ilot choke - Meter In 2 Ext. pilot/ext. drain 89 Stroke dj. & Ends 4# Int. pilot/int. drain 90 1/4 S hreads 5 Ext. pilot/int. drain # Not available with 002, 008 & 009 spools. Single operator, 2 position, spring centered. to and to when energized. H Single operator, 2 position, spring offset. to and to in offset position. K Single operator, 2 position, spring centered. to and to when energized. old: Designates ier I products and options. b b b Symbol a a a Design Series NOE: Not required when ordering. Only spools 020 and 030. his condition varies with spool code. Non-old: Designates ier II products and options. hese products will have longer lead times. b a Dimensions ir Operated Inch equivalents for millimeter dimensions are shown in (**) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 103 Elyria, Ohio, US

27 echnical Information Series D31*L General Series D31*L directional control valves are 5-chamber, pilot operated, lever controlled valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Specifications ressure Drop Chart Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H Max. Operating ressure Max. ank Line ressure Maximum Flow 345 ar (5000 SI) Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) See Switching Limit Charts ilot ressure Oil Min 6.9 ar (100 SI) Oil Max 345 ar (5000 SI) Max. Drain ressure 34 ar (500 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) VISCOSIY CORRECION FCOR Viscosity (SSU) % of Δ (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. D31VL ressure Drop Reference Chart -- Curve Number Spool Shifted Center Condition No (-) (-) (-) (-) (-) (-) (-) D31VL ressure Drop vs. Flow he chart to the left provides the flow vs. pressure drop curve reference for the D31VL Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D31VL with a number 001 spool. o the right of spool number 001, locate the number 3 in the - column, and 2 in the - column. Using the top graph, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. 104 Elyria, Ohio, US

28 echnical Information Series D31*L Ordering Information D L Directional Control Valve asic Valve 31D NF D05HE, CEO 5H (ISO) 31V NF D05H, CEO 5 Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #008 and #009 spools. See installation information for details ** 009* 020** 030* Valve Weight: 5.4 kg (12.0 lbs.) Standard olt Kit: K98 Metric olt Kit: KM98 Lever Operated ilot Symbol * 009 and 030 spools have open crossover. ** 008 and 020 spools have closed crossover. Spool Style ilot Supply Seal and Drain N V Nitrile Fluorocarbon Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. D Dbl. operator, 2 position, detent. E 1 Int. pilot/ext. drain 2 Ext. pilot/ext. drain 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 002, 008 & 009 spools. Sgl. operator, 2 position, spring centered. to and to in shifted position. H Sgl. operator, 2 position, spring offset. to and to in offset position. K Sgl. operator, 2 position. Spring centered. to and to in shifted position. old: Designates ier I products and options. Valve Variations Symbol Design Series NOE: Not required when ordering. Omit Standard 7 ilot choke meter out 8 Stroke adj. End 9 Stroke adj. End 60 ilot choke meter in 89 Stroke adj. & Ends Only spools 020 and 030. his condition varies with spool code. Non-old: Designates ier II products and options. hese products will have longer lead times. Dimensions Lever Operated Inch equivalents for millimeter dimensions are shown in (**) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 105 Elyria, Ohio, US

29 echnical Information Series D3* General Series D3* directional control valves are 5-chamber, oil pilot operated valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. High pressure and flow ratings Increased performance options in a compact valve. Specifications ressure Drop Chart Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H Max. Operating 345 ar (5000 SI) ressure Max. ank 207 ar (3000 SI) Line ressure ilot ressure Oil Min: 6.9 ar (100 SI) Oil Max: 345 ar (5000 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) D3 ressure Drop Reference Chart -- Curve Number Spool Shifted Center Condition No (-) (-) (-) (-) (-) (-) (-) VISCOSIY CORRECION FCOR Viscosity (SSU) % of Δ (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. D3 ressure Drop vs. Flow he chart to the left provides the flow vs. pressure drop curve reference for the D3 Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D3 with a number 1 spool. o the right of spool number 1, locate the number 3 in the - column, and 2 in the - column. Using the top graph, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. 106 Elyria, Ohio, US

30 echnical Information Series D3* Ordering Information D Directional Control Valve asic Valve 3D NF D05HE, CEO 5H 3 NF D05H, CEO 5 * 9 and 30 spools have open crossover. ** 8 and 20 spools have closed crossover. Hydraulic ilot Valve Weight: Single Operator 1.4 kg (3.0 lbs.) Double Operator 1.6 kg (3.5 lbs.) Standard olt Kit: K98 Metric olt Kit: KM98 Seal Kit: Nitrile SKD3 Fluorocarbon SKD3V ** 9* 20** 30* Spool Style ilot Supply Seal and Drain Symbol N V Nitrile Fluorocarbon Single operator, 2 position, spring offset. to and to in offset position. C 2 Ext. pilot/ext. drain 5# Ext. pilot/int. drain # vailable on and H styles only. Double operator, 3 position, spring centered. H Single operator, 2 position, spring offset. to and to in offset position. Only spools 20 and 30. Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends Symbol his condition varies with spool code. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator X. Note operators reverse sides for #8 and #9 spool. See installation information for details. old: Designates ier I products and options. Valve Variations Non-old: Designates ier II products and options. hese products will have longer lead times. Design Series NOE: Not required when ordering. Dimensions Oil Operated Inch equivalents for millimeter dimensions are shown in (**) 76.2 (3.00) 47.8 (1.88) # 6 SE (4.40) 83.0 (3.27) See Note 36.0 (1.42) 50.5 (1.99) (4.76) 47.2 (1.86) 58.9 (2.32) (4.76) 35.0 (1.38) Note: 30.0mm (1.18") from bottom of bolt home counterbore to bottom of valve. 107 Elyria, Ohio, US

31 Installation Information Series D31, D3* FOR MXIMUM VLVE RELIILIY, DHERE O HE FOLLOWING INSLLION INFORMION. he following is important installation information which applies to all directional control valves described in this catalog. Mounting osition Detent Horizontal Spring Offset Unrestricted Spring Centered Unrestricted Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst. ( SSU) t 38 C (100 F) is recommended. he absolute operating viscosity range is from cst. ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatment. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate esters or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions and petroleum oil may be used with SNDRD seals. Filtration For maximum valve and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid (SE class 4/ISO 16/13). Silting Silting can cause any sliding spool valve to stick and not spring return if held under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Special Installations Consult your arker representative for any application requiring the following: Mounting atterns Series NF Size D31V*, D3 D05H, CEO 5 3/8" D31D*, D3D, D31NW D05HE, CEO 5H 3/8" orque Specifications he recommended torque values for the bolts which mount the valve to the manifold or subplate are as follows: 16.3 Nm (12 ft-lb). 1/16 ipe lug for Variations 1 & 4 orque to:11.67 ± 1.67 Nm (105 ± 15 in-lbs) 1/16 ipe lug for Variations 4 & 5 orque to:11.67 ± 1.67 Nm (105 ± 15 in-lbs) NF D05HE, CEO 5H attern D31DW 1/16 ipe lug for Variations 1 & 4 orque to:11.67 ± 1.67 Nm (105 ± 15 in-lbs) 108 1/16 ipe lug for Variations 4 & 5 orque to:11.67 ± 1.67 Nm (105 ± 15 in-lbs) NF D05H, CEO 5 attern D31VW Elyria, Ohio, US

32 Installation Information Series D31 SERIES D31*W, D31*, D31*L ILO OERED, DIRECIONL CONROL VLVES ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. No spring style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Electrical Failure or Loss of ilot ressure (D31*) Should electric power fail or loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. Electrical Characteristics (Detented Spool) Only a momentary energizing of the solenoid is necessary to shift and hold a detented spool. Minimum duration of the signal is 0.1 seconds for DC voltages. For C voltages the response time is 0.06 seconds. Spool position will be held provided the spool centerline is in a horizontal plane, and no shock or vibration is present to displace the spool. ilot/drain Characteristics ilot ressure: 6.9 to 345 ar (100 to 5000 SI) External: n oil source sufficient to maintain minimum pilot pressure must be connected to the X port of the main body. When using the external pilot variation, an M5 x 0.8 x 6mm long set screw must be present in the D31*W, D31*, D31*L Flow aths main body pilot passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with pilot code 2 or 5. Internal: Flow is internally ported from the pressure port of the main valve body to the port of the pilot valve. he pressure developed at the port of the pilot valve must be 100 SI (6.9 ar) minimum at all times. If the valve center condition allows flow from pressure to tank, 100 SI (6.9 ar) back pressure must be developed in the tank line to ensure sufficient pilot force at. he X port in subplate must be plugged when using internal pilot variation (1/16 N). ilot Valve Drain: Maximum pressure 102 ar (1500 SI), 207 ar (3000 SI) optional. External: When using an external drain, an M6 x 1 x 10mm long set screw must be present in the main body drain passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with drain code 1 or 2. Drain flow from the pilot valve is at the Y port of the main body and must be piped directly to tank. Maximum drain line pressure is 102 ar (1500 SI), 207 ar (3000 SI) optional. ny drain line back pressure is additive to the pilot pressure requirement. Internal: Drain flow from the pilot valve is internally connected to the main valve tank port. ank and drain pressure are then identical so tank line pressure should not exceed 102 ar (1500 SI), 207 ar (3000 SI) optional. ny tank line back pressure is also additive to the pilot pressure requirement. If flow surges (a cause of pressure surges) are anticipated in the tank line, an external drain variation is recommended. he Y port in subplate must be plugged when using internal drain variations. Style No Solenoid/Operator Solenoid/Operator Solenoid/Operator Energized Energized Energized Spring Offset and and C Spring Centered Centered and and D Detented Last osition Held and and E Spring Centered Centered and F Spring Offset, Shift to Center and Centered H Spring Offset and and K Spring Centered Centered and M Spring Offset, Shift to Center and Centered D31*W only. 109 Elyria, Ohio, US

33 Installation Information SERIES D3, D3D ILO OERED DIRECIONL CONROL VLVES ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Separate tank and drain lines should be piped in installations where line surges are expected. Loss of ilot ressure Should oil pilot pressure fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. Series D31, D3* ilot Drain Characteristics ilot ressure: 6.9 to 345 ar (100 to 5000 SI) Direct pilot operated valves use the X and Y ports to supply pilot oil directly to the ends of the spool, providing spool shifting force. block mounted on top of the valve body is internally cored to make the necessary connections. hus when X is pressurized, Y is used as a drain; and when Y is pressurized, X becomes the drain. ny back pressure in these lines when they are being used as a drain is additive to the pilot pressure requirement. Internal Drain: On spring offset models, only the X port is pressurized, as the spring returns the spool to its at rest position. On these models, Y may be internally drained through the main tank passage in the valve. Mounting attern D3 valves may be mounted on a standard D05 pattern subplate or manifold only if the X and Y ports are externally connected to the pilot block on top of the main body. ll other mounting styles require a D05H or D05HE pattern which incorporates ports for the X and Y pilot and drain passages. Location of these ports can be found on the Recommended Mounting Surface pages in this section. D3 Flow ath/ilot ressure Style Recommended X & Y X ort Y ort Special Notes Control Valve De-ressurized ressurized ressurized For ilot Oil wo osition X ort may be pressurized to Spring Offset,,, assist spring in returning spool to offset position (ext. only) hree osition Flow paths will be reversed on C Spring Centered Center,, valves with tandem center (8) spools wo-osition Y ort may be pressurized H Spring Offset,,, to assist spring in returning spool to offset position 110 Elyria, Ohio, US

34 Installation Information Series D31, D3* Series D31VW, D31V, D31VL, D3 Subplate Mounting NF D05H, CEO 5 Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r and smooth within micro-meters (32 micro-inch). orque bolts to 16.3 Nm (12 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted For maximum valve reliability, adhere to the following installation information. Mounting attern NF D05H, CEO 5 Inch equivalents for millimeter dimensions are shown in (**) 111 Elyria, Ohio, US

35 Installation Information Series D31, D3* Series D31DW, D31D, D31DL, D3D, D31NW Subplate Mounting NF D05HE, CEO 5H Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r. and smooth within micro-meters (32 micro-inch). orque bolts to 16.3 Nm (12 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted For maximum valve reliability, adhere to the following installation information. Mounting attern NF D05HE, CEO 5H Inch equivalents for millimeter dimensions are shown in (**) 50.8 (2.00) 27.0 (1.06) 54.0 (2.13) 37.3 (1.47) 16.7 (.66) 61.9 (2.44) 91.9 (3.62) min. with X& Y ports 72.1 (2.84) min. without X& Y ports 21.4 (.84) 11.1 (.44) 11.1 (.44) 6.4 (.25) 7.9 (.31) 57.9 (2.28) min (1.81) 43.6 (1.72) 32.5 (1.28) X Y 6.3 (O.25) max. X & Y ports.56 (.022) L 75.0 (2.95) 11.2 (O.44) max....&ports.56 L (.022) M6x1 (1/4-20) UNC-2 thread x 9.7 (.38) min. thread depth 4 places.28 (.011) S 112 Elyria, Ohio, US

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Directional Control Valves. Application. Features. Operation.

Directional Control Valves. Application. Features. Operation. Catalog HY14-2500/US Introduction pplication Series D101 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D61VW General Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2500/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH SECION Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories echnical Information General Description Series D61VW directional control valves

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D101VW General Series D101VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Catalog HY14-2502/US Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage 4-way valves. hey are available in 2 or 3-

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2502/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform

More information

Directional Control Valves

Directional Control Valves echnical Information General Description he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available

More information

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-2500/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Catalog HY14-2500/US Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US echnical Information General Description Series D1VW directional control

More information

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way

More information

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire ulletin 2544-1/US Introduction pplication arker D1M Series hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3 position styles. hey are

More information

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-252/US Introduction pplication arker D3 Series hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3 position. hey are manifold mounted

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US Industrial Hydraulic Valves WRNING USER RESONSIILIY FILURE OR IMROER SELECION

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US Industrial Hydraulic Valves LH WRNING USER RESONSIILIY FILURE OR IMROER

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

Direct Operated Proportional DC Valves

Direct Operated Proportional DC Valves echnical Information Direct Operated roportional DC Valves Series D1F and D3F General Series D1F and D3F directional control valves of nominal sizes NG6 (CEO 3) and NG10 (CEO 5) respectively, provide variable

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Directional Controls

Directional Controls VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................

More information

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow NF D3 O E R I N G N D E C H N I C L D RINGS Maximum Flow... See Chart Maximum Operating ressure (, and orts)... 3 ar ( SI) Maximum ank Line ressure... 13 ar (1 SI) Mounting attern... ISO 441--3-4-, NF-D3

More information

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves Service Bulletin 91 Design Effective: May 1, 2007 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SECIFICIONS D05H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol

More information

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves Service Bulletin 91 Design Effective: May 1, 2007 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This

More information

Manapak Sandwich Valves. General Description

Manapak Sandwich Valves. General Description echnical Information Series RM General Description RM Series relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. With D3 size, they can also be configured

More information

High Pressure, Subplate Mounted Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H05 5 gpm (19 L/min) nominal 8000 psi (560 bar) Sliding-spool H05 valves provide true four-way control in a simple

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Directional Controls

Directional Controls Vickers Directional Controls ilot Operated Directional Valves DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000

More information

Bankable Control Valves

Bankable Control Valves Hydraulics ankable Control Valves Catalog 3123/US Catalog 3123/US Contents ankable Control Valves WRNING FILURE OR IMROER SELECION OR IMROER USE OF HE RODUCS ND/OR SYSEMS DESCRIED HEREIN OR RELED IEMS

More information

High Pressure, Subplate Mounted Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H03 5 gpm (19 L/min) nominal 10 000 psi (700 bar) H03 valves are rated for 5 gpm (19 L/min) nominal flow at pressures

More information

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

G SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) G SERIES SHOCKLESS TYPE "G" SRIS SHOCKLSS Y NOID ORD DIRCIL VLVS G-DSG-1/3 (1/, 3/) "G" SRIS SHOCKLSS Y NOID CROLLD ILO ORD DIRCIL VLVS G-DSHG-/ (1/, 3/) Mounting Up to 5 Ma (33 SI), 5 L /m in (.1 U.S.GM) ub. C-5 DIRCIL CROLS

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SECIFICIONS D0H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol Drive

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

Pilot Operated Directional Valves

Pilot Operated Directional Valves ilot Operated Directional Valves Catalog DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) NF D10, ISO-4401-10,

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications echnicl Informtion Generl Description directionl control vlves re high performnce, 5-chmer, direct operted, wet rmture, solenoid controlled, 3 or 4-wy vlves. hey re ville in 2 or 3-position nd conform

More information

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax: GENERL FEURES SNDRD FEURES High ressure/ High Flow: 65 gpm/ psi ilot Operation: Main spool controlled by D0 solenoid pilot valve- allows for addition of modular valves to reduce shifting shock. Oil Immersed,

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM-- -

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

Directional Controls

Directional Controls Vickers Directional Controls Mechanical ctuators Directional Control Valves Directional Control Valves 310 bar (4500 psi) Flows to 114 l/min (30 USgpm) NF D05, ISO-4401-05 DG1V4-01**-10 Knob Operated DG17V4-01**-10

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: DIRECIONL VLVE OERION Directional Valve Features, Selection and Operating Recommendations CONC INFORMION US Headquarters Dynex/Rivett Inc. 770 Capitol Drive ewaukee, WI 3072 U.S.. el: 262-69-2222 FX: 262-69-032

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications ilot Operated Directional s DIRECIONL CONROLS hese valves perform a change over of spool by hydraulic pilot and shift the direction of oil flow. EIC-E-04-0 Specifications Model Numbers Maximum Flow L/min.

More information

MDT. Monoblock directional control valves MDT - Directional control valve

MDT. Monoblock directional control valves MDT - Directional control valve Monoblock directional control valves - Directional control valve efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES echnical data Nominal flow 35 l/min 9. US gpm Nominal

More information

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled ilot Operated Directional Valves Electronic Circuit X Specifications Descriptions G-DSHG-4-3C - - - -/9 G-DSHG-6-3C - - - -/9 Max. Flow /min (U.S.GM) 16 (4.3) (66.1) 1 1 Max. Operating

More information

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements Explosion-Proof Valves ccording to Directive 94/9/EC (EX) and IECEx Requirements WRNING USER RESPONSIILIY FILURE OR IMPROPER SELECION OR IMPROPER USE OF HE PRODUCS DESCRIED HEREIN OR RELED IEMS CN CUSE

More information

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar 41 510/107 ED EXLOSION-ROOF VERSION SOLENOID OERED DIRECIONL CONROL VLVES in compliance with EX 94/9/CE SERIES 21 MD1K-MD1KD ISO 4401-03 (CEO 03) E44K-E44KD CEO 05 E074K-E074KD ISO 4401-07 (CEO 07) E54K-

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM--B -

More information

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768 /- and /-Way roptional Directional Control Valve Direct Operated, Model WR (Series X) Size 6 and... 6 SI ( bar).... GM (9 L/min) R 9 /6.98 R 9 /6.98 Replaces:.9 Characteristics: F the open loop control

More information

Pilot Operated Directional Valves

Pilot Operated Directional Valves ilot Operated Directional Valves Catalog DG3V-8; 7 l/min (185 USgpm) 35 bar (5 psi) DG5V-8; 7 l/min (185 USgpm) 35 bar (5 psi) NF D8, ISO-441-8, CEO 8 Introduction General Description he Size 8 Directiona

More information

Directional control valves NG6...NG32 D03...D10 6

Directional control valves NG6...NG32 D03...D10 6 Directional control valves NG6...NG32 D03...D10 6 DIRECIONL CONROL VLVES 1 Index DO3 (NG6) age 2 to 22 D05 (NG10) age 23 to 42 D07 (NG16) age 43 to 54 D08 (NG25) 3000 SI age 55 to 65 D08 (NG25) 4600 SI

More information

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard Technical Information General Description pilot operated proportional valves are designed for high precision applications that require a safe middle position of the main spool at power down. The pilot

More information

Directional Controls

Directional Controls VICKERS Directional Controls DG3V-7, 20 Series, ilot Operated DG5V-7, 40 Series, Solenoid Controlled, ilot Operated ISO 440 Size 07 ypical Section DG5V-7-2C Spring-Centered Valve Example Basic Characteristics

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional irectional Control Valves 200 - - 991210 - - 03/09.2015 1/220 8 Sectional directional control valves HS11 8 valves... p.101 Contents 8.1 General specification 101 8.2 imensional

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions N-1 Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SPECIFICIONS D08H Pattern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol

More information

EMechanically Operated Directional Valves

EMechanically Operated Directional Valves E DIRECIONL CONROLS Cam Operated Directional Valves hese valves may be used to shift the direction of oil flow by depressing the spool by way of a cam. Specifications Max. Operating Max. -Line Max. Flow

More information

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE Technical Information Series D*1FB General Description Series D*1FB pilot operated proportional directional valves come in 4 sizes: D31FB NG10 (CETOP 5) D41FB NG16 (CETOP 7) D91FB NG25 (CETOP 8) D111FB

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 3/ and 4/ directional seat valves with solenoid actuation RE 047-XH-B/01.10 Replaces: 09.07 ype E-.SE 6...XH ype W-.SE 6...XH Size 6 Component series 6X Maximum operating pressure 40 bar Maximum flow

More information

Proportional Pressure Reducing Valve Series D1FV

Proportional Pressure Reducing Valve Series D1FV Characteristics roportional ressure Reducing Valve Series D1FV he proportional pressure reducing valves series D1FV are available with and without onboard electronics (OE). D1FV OE he digital onboard electronics

More information

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32 www.atos.com able E0854/E Solenoid al valves DHI, DHE, DHER two stage, ISO 440 size 0, 6, 5 and 3 DHI, DHE and DHER are spool, two or three position, two stage al solenoid valves. hey are operated by a

More information

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN> DFE1 Ordering codes Description example : Diverter valve DFE1/3 18 ES - W 22-12VDC - SE - 1. 4. 5. 3. 5. 2. Valve is supplied painted as standard, with one coat of rimer black antirust paint II 5.

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 /2 and 4/2 directional seat valves with solenoid actuation RE 22047-XH-B2/09.12 Replaces: 05.12 ype E-.SE 6...X... ype W-.SE 6...X... Size 6 Component series 6X Maximum operating pressure 420 bar

More information

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8. R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to

More information

NG06. General Size NG6 NG10 Design

NG06. General Size NG6 NG10 Design Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves 200--991210-N-03/09.2015 03 / 10.04 1/220 11 Sectional directional control valves HDS30 Contents 11.1 General specifications 197 11.2 Dimensional data

More information

High Pressure, High Flow Rate Modular Valves

High Pressure, High Flow Rate Modular Valves eatures Installation and mounting space can be minimized. No special skill is required for assembly and any addition or alternation of the hydraulic circuit can be made quickly and easily. roblems such

More information

Pump Safety Block Model DBA... / DBAW, Series 1X

Pump Safety Block Model DBA... / DBAW, Series 1X ump Safety lock odel D... / DW, Series X Sizes to 6 SI ( bar) 7 G (65 L/min) R 5 88/.95 Replaces:.9 ermits low pressure start-up and by-pass of pump Direct mounting to SE pressure port of pump Light biasing

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve. Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application

More information

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ) 4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ) RE 18301-12 Edition: 02.2016 Replaces: 07.12 07.2012

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves motion and progress 200 991210 03 / 10.04 1/220 HDS11 8 Sectional directional control valves HDS11 8 Standard valves................................................................

More information

Monoblock directional control valves DL - Directional control valve

Monoblock directional control valves DL - Directional control valve Monoblock directional control valves DL - Directional control valve DL Before use, carefully read the GENERAL INSRUCIONS FOR USE OF DIRECIONAL CONROL VALVES 398SMD008I00-06-2-208 DL echnical data Nominal

More information

Open center control block in mono block design MO-16, 22, 32

Open center control block in mono block design MO-16, 22, 32 Open center control block in mono block design MO-,, 3 RE 35 Edition: 0.0 Replaces: 0.003 Sizes,, 3 Series X Maximum working pressure on the pump side 350 bar on the consumer side 0 bar Maximum flow MO-:

More information

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED NFPA SIZE D10 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may be reduced from that shown if a three-way circuit (half circuit) is used,

More information

Pressure Control Valves. General Description. Specifications. Ordering Information

Pressure Control Valves. General Description. Specifications. Ordering Information Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves motion and progress 1/220 10 Sectional directional control valves HDS20 Contents 10.1 General specifications 177 10.2 Dimensional data 178 10.3 erformances

More information

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE) 4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OE) ype 4WRDE Nominal size to 35 Component series 5X Maximum operating pressure 3 bar

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

Mounting and Assembly of Sandwich Bodies

Mounting and Assembly of Sandwich Bodies Mounting and ssembly of Sandwich odies Mounting of ISO 0 (CEO ) Sandwiches Many of Sun s ISO 0 (CEO ) sandwich bodies are designed for multi-functional use to permit maximum circuit flexibility. With the

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SPECIFICAIONS D05 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONAC INFORMAION USA Headquarters Dynex/Rivett

More information

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve 4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve RE 183-54/7.12 Replaces: 1.9 1/8 8_58 (EDZ-VEI) Size 4 Series

More information

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents. Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OE) ype 4WRDE RE 997 Edition: 6-5 Replaces: 99 (NG and NG6) Sizes and 6 Component series 6X Maximum

More information

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves igh Response ype roportional Electro-ydraulic s igh response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVD. Direct

More information

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections 4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RE 18301-12/07.12 1/10 D8_5 (EDD-XZ) Size 8 Series 00 Maximum pressure (pump side) 310 [4500

More information

3/2 and 4/2 directional poppet valve with solenoid actuation

3/2 and 4/2 directional poppet valve with solenoid actuation Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 3/2 and 4/2 directional poppet valve with solenoid actuation ype M-.SED Size 10 Component

More information

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES SECION ILE HEC2003/2004 SERIES SERVO VLVE SYSEM he HEC2003/2004 Series Servo System features a high response servo valve, a manifold mounted filter, and three different mechanical mounting options. he

More information