1 echnical Information General Description he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03/ CEO 3 mounting patterns. Features Mechanically tunable soft shift roportional spools, 21 standard spool styles available Repairable override DC surge suppression Nine electrical connection options C & DC lights available (CS approval for solenoids and lights) Internally ground Easy access mounting bolts Waterproof (NEM 4 rated) Explosion proof CS approved and U.L. recognized available No tools required for coil removal C rectified coils Response ime* Nominal response time (milliseconds) at 345 ar (5000 SI) is 32 L/M (8.5 GM). Solenoid ype ull-in Drop-Out C DC 8 Watt or 10 Watt DC 30 Watt * For soft shift, see ordering code X-number. Specifications Mounting attern NF D03, CEO 3; NG 6 Mounting DIN Interface ISO CEO R35H , NF D03 Maximum,, ressure 345 ar (5000 SI) Standard CS 276 ar (4000 SI) ank: 103 ar (1500 SI) Standard 207 ar (3000 SI) Optional with H, FH, G, LG CS 103 ar (1500 SI) p65, dd 17 arker Hannifin Corporation Elyria, Ohio, US
2 Ordering Information Standard Valves D Directional Control Valve 1V asic Valve ctuator# Spool Style Seal Solenoid Voltage 2MD NF D03 CEO 3 DIN NG6 W HW Description Solenoid, Wet in, Screw-in Reversed Wiring # Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D1VHW***. N V E * Description Nitrile Fluorocarbon ER * Contact HVD for availability. D G J K L N Q R U Y Z Description 24/50 VC 120 VDC 198 VDC 24 VDC 12 VDC 6 VDC 220/50 VC 100/60 VC 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC 250 VDC Symbol Symbol * * 008*, 030** 009** p65, dd * 008, 020 & 026 spools have closed crossover. ** 009 & 030 spool have open crossover. See Universal Spool Chart for other spool options. Description Symbol * 2 position, spring offset to C 3 position, spring centered D 2 position, detent, to and to E F 2 position, spring centered and to 2 position, spring offset to and centered H* 2 position, spring offset to K M 2 position, spring centered and to 2 position, spring offset to and centered * 020, 026 and 030 spools only. 020 and 030 spools only. 18 b b b b b arker Hannifin Corporation Elyria, Ohio, US a a a a a
3 Ordering Information Standard Valves Solenoid Connection Coil Options ube Options Options Electrical Options Shift Response and Indication pprovals Valve Design Variations Series NOE: Not required when ordering. Description C Conduit ox D Metric lug (M12X1), DESIN E Explosion roof G lug-in H* Single Spade J** Deutsch (D06-25) L Dual Screw Lug M** Metri-ack (150) DIN with lug S Double Spade W* DIN w/o lug * Not available with lights. ** See valve variations for others. DC only p65, dd Omit D E F** Description High Watt Explosion roof, EEXD EX Explosion roof, EEXME EX Low Watt C CS Hazardous Location L*** 8 Watt O Explosion roof, MSH U Explosion roof, UL/CS X* No Coils * See solenoid voltage code to specify proper tube. ** C only. *** DC/C Rectified only. pplicable to conduit box and plug-in style only. Omit H M G Omit R W Description Low ressure, C only High ressure, C only Low ressure, DC-WI only High ressure, DC-WI only Omit J Description Standard Extended with oot None Repairable Waterproof rotection 19 Description Omit Standard Response S2* Soft Shift, 0.020" Orifice S3* Soft Shift, 0.030" Orifice S4* Soft Shift, 0.040" Orifice S5* Soft Shift, 0.050" Orifice S6* Soft Shift, 0.060" Orifice SN* Soft Shift, No Orifice I7 Monitor Switch Direct Op. End Stroke I8 Monitor Switch Direct Op. Start Stroke * Not available with 8 watt. Description No Options Diode Surge Suppressor Rectified Coil Description Omit Standard Valve 4* C.S.. pproved K UL Recognition * Not available with high pressure tube. Description 5 Signal Lights 6 Manaplug - rad Harrison Mini 7 Manaplug - rad Harrison (12x1) Micro 56 Manaplug (Mini) with Lights 7 Manaplug (Micro) with Lights (D1 only) 1 Manaplug (Mini) Single Sol. 5-pin 1 Manaplug (Micro) Single Sol. 5-pin 1C Manaplug (Mini) Single Sol. 5-pin, with Lights 1D Manaplug (Micro) Single Sol. 5-pin, with Lights 4D wist & Lock (Old 5426) 4E ush (Old x5450) Valve Weight: Single Solenoid Double Solenoid Standard olt Kit: Metric olt Kit: 1.36 kg (3.0 lbs.) 1.6 kg (3.5 lbs.) K209 KM209 arker Hannifin Corporation Elyria, Ohio, US
4 Catalog HY /US echnical Information Solenoid Ratings Insulation System Class F llowable Deviation -10% to +15% for DC and C rectified coils from rated voltage -5% to +5% for C Coils rmature Wet pin type CS File Number LR60407 Environmental DC Solenoids are rated at NEM 4 (I67) Capability or better when properly wired and installed. Contact HVD for C coil applications. Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the NEC M.S.H.. (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 CS Hazardous Location Class II, Groups E, F & G * llowable Voltage Deviation +/- 10% Note that C coils are single frequency only. Voltage In Rush mps In Rush mps Holding mps Watts Resistance Voltage ower mperage D1VW 3MM D1VW D1VW D1VW 24/50 VC, High Watt 7.00 mps 168 V 2.65 mps 28 W 1.67 ohm(s) D L 120 VDC N/ N/ 0.09 mps 10 W ohm(s) N/ N/ 0.26 mps 30 W ohm(s) E 24/60 VC, High Watt 6.00 mps 144 V 1.85 mps 20 W 1.67 ohm(s) 24/50 VC, High Watt 7.00 mps 168 V 2.65 mps 28 W 1.67 ohm(s) G L 198 VDC N/ N/ 0.05 mps 10 W ohm(s) N/ N/ 0.15 mps 30 W ohm(s) J L 24 VDC N/ N/ 0.44 mps 10 W ohm(s) N/ N/ 1.32 mps 30 W ohm(s) K L 12 VDC N/ N/ 0.88 mps 10 W ohm(s) N/ N/ 2.64 mps 30 W 4.32 ohm(s) L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohm(s) N/ N/ 5.00 mps 30 W 1.20 ohm(s) M L 9 VDC N/ N/ 1.11 mps 10 W 8.12 ohm(s) N/ N/ 3.35 mps 30 W 2.67 ohm(s) 110/50 VC 0.38 mps 19 W ohm(s) R 24/60 VC, High Watt 8.00 mps 192 V 2.70 mps 27 W 1.40 ohm(s) F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohm(s) S ***Specials*** SEE ELOW 240/60 VC, High Watt 0.77 mps 185 V 0.26 mps 25 W ohm(s) 220/50 VC, High Watt 0.82 mps 180 V 0.31 mps 27 W ohm(s) F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohm(s) F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohm(s) U L 98 VDC N/ N/ 0.10 mps 10 W ohm(s) X L 16 VDC N/ N/ 0.63 mps 10 W ohm(s) Y 120/60 VC, High Watt 1.55 mps 186 V 0.49 mps 25 W ohm(s) 110/50 VC, High Watt 1.65 mps 182 V 0.58 mps 27 W ohm(s) F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohm(s) F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohm(s) L* 120/60 VC, 10 Watt 0.63 mps 83 V 0.18 mps 10 W ohm(s) L* 110/50 VC, 10 Watt 0.73 mps 79 V 0.20 mps 10 W ohm(s) *H 120/60 VC, High ressure 1.40 mps 168 V 0.50 mps 26 W ohm(s) *H 110/50 VC, High ressure 1.48 mps 163 V 0.60 mps 28 W ohm(s) Z L 250 VDC N/ N/ 0.04 mps 10 W ohm(s) N/ N/ 0.13 mps 30 W ohm(s) Specials S Other voltages/frequencies may be available Contact HVD for more information Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohm(s) 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohm(s) N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohm(s) Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohm(s) 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohm(s) Q 100/60 VC 1.90 mps 192 V 0.70 mps 27 W ohm(s) K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohm(s) J 24 VDC N/ N/ 1.38 mps 33 W ohm(s) D 120 VDC N/ N/ 0.28 mps 33 W ohm(s) Z 250 VDC N/ N/ 0.13 mps 33 W ohm(s) p65, dd 20 arker Hannifin Corporation Elyria, Ohio, US
5 lug-in ox, Double DC Solenoid 44.9 (1.77) 87.8 (3.46) (5.66) 54.3 Min. Coil (2.14) 1/2 NF hd. oth Ends 49.6 (1.95) (2.60) 93.2 (3.67) (9.62) lug-in ox, Single DC Solenoid 44.9 (1.77) 87.8 (3.46) 1/2 NF hd. oth Ends 49.6 (1.95) 54.3 (2.14) Min. Coil (7.42) (2.60) 93.2 (3.67) p65, dd 21 arker Hannifin Corporation Elyria, Ohio, US
6 Hirschmann, Double DC Solenoid 12.0 (0.47) Min. Connector 72.6 (2.86) (4.54) (5.59) 54.3 (2.14) Min. Coil 25.3 (1.00) 23.0 (0.91) 66.3 (2.61) 77.6 (3.06) (9.62) Hirschmann, Single DC Solenoid 23.0 (0.91) 25.3 (1.00) 54.3 (2.14) Min. Coil (3.97) 72.6 (2.86) 12.0 (0.47) Min. Conn (3.06) 66.3 (2.61) (6.63) p65, dd 22 arker Hannifin Corporation Elyria, Ohio, US
7 Conduit ox, Double C Solenoid 36.8 (1.45) 79.9 (3.15) (5.00) (1.68) Min. Coil ½ NF hread oth Ends 49.5 (1.95) 3.0 (0.19) See Note (2.60) 94.6 (3.72) (8.30) Note: 22.0 mm (.87 ) from bottom of bolt hole counterbore to bottom of valve. Conduit ox, Single C Solenoid (1.68) Min. Coil 84.0 (3.31) 36.8 (1.45) ½ NF hread oth Ends 49.5 (1.95) 3.0 (0.19) (2.60) 94.6 (3.72) (6.44) p65, dd 23 arker Hannifin Corporation Elyria, Ohio, US
8 Conduit ox, Double C Solenoid with Variation 6 (Manaplug) & Variation (Extended ) 36.8 (1.45) 95.7 (3.77) (4.99) 42.8 (1.69) Min. Coil Connector NF (1.00) Hex 49.5 (1.95) 3.0 (0.19) Extended (2.60) 94.6 (3.72) 61.2 (2.41) Minimum Coil (8.86) Conduit ox, Double DC & C Rectified Solenoids with Variation 6 (Manaplug) & Variation (Extended ) Extended 36.8 (1.45) (5.59) 95.7 (3.77) 79.9 (3.15) 54.3 (2.14) Min. Coil Connector per NF (1.00) Hex (2.60) 49.5 (1.95) 3.0 (0.19) 94.6 (3.72) 72.7 (2.86) Min. Coil (10.01) p65, dd 24 arker Hannifin Corporation Elyria, Ohio, US
9 Conduit ox, Double C Solenoid with Variation R (Repairable ) 36.8 (1.45) 79.9 (3.15) (5.44) 54.8 (2.16) Min. Coil ½ NF hread oth Ends 3.0 (0.19) 49.5 (1.95) 94.6 (3.72) (2.60) (9.19) Conduit ox, Double DC Solenoid with Variation R (Repairable ) 44.9 (1.77) 87.8 (3.46) (6.10) 66.3 (2.61) Min. Coil 1/2 NF hd. oth Ends 49.6 (1.95) 93.2 (3.67) (2.60) (10.51) p65, dd 25 arker Hannifin Corporation Elyria, Ohio, US
10 DESIN, Double DC Solenoid 48.0 (1.89) 90.7 (3.57) (5.59) 54.3 (2.14) Min. Coil 70.3 (2.77) 50.8 (2.00) (9.54) DESIN, Single DC Solenoid 90.7 (3.57) (5.59) 543 (2.14) Min. Coil 70.3 (2.77) 50.8 (2.00) (6.59) p65, dd 26 arker Hannifin Corporation Elyria, Ohio, US
11 Explosion roof U.L. & C.S.., Double Solenoid 60.4 (2.38) (6.44) 18 Inch Lead Wires Standard 1/2" N 94.4 (3.72) (5.15) (11.98) Explosion roof M.S.H.., Double Solenoid 73.0 (2.87) (0.30) 3/4-20 UNF hd (2.38) (6.44) 3/4-20 UNF hd (1.50) (4.45) (5.15) (6.44) Explosion roof EX, Double Solenoid 73.0 (2.87) (0.30) 74.7 (2.94) 69.9 (2.75) 19.4 (0.76) M20 x 1.5-6H hd (3.97) 42.8 (1.69) (5.19) (3.96) 7.5 (0.30) 73.5 (2.89) (5.55) (12.78) p65, dd 27 arker Hannifin Corporation Elyria, Ohio, US
12 Conduit ox, Single DC Solenoid with Variation I7 (Monitor Switch) & Variation (Extended ) 72.7 (2.86) Min.Coil (4.53) 12.0 (0.47) Min. Conn (1.95) 3.0 (0.12) Extended (10.82) 81.9 (3.22) 70.6 (2.78) 94.6 (3.72) Monitor Switch (valve variation I7) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. Regulator lock Diagram Inductor (Extended, or Energized osition) in 1 (Input 24VDC) in 2 (Output Normally Open) in 3 (Output Normally Closed) in 4 (Ground erminal) For repetitive switch power-up conditions, please consult factory p65, dd 28 arker Hannifin Corporation Elyria, Ohio, US
13 ccessories Conduit ox (connection option G & C) Interface cm (6.0 inch) lead wires, 18 awg. Waterproof lug-in Conduit ox NEM 4 rated hoenix connector Lights, Manaplug available Signal Lights (valve variation 5) Interface LED Manaplug (valve variations 6, 56, 630) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Solenoid (Negative) Wire #3 (Red/lack) Ground Wire #1 (Green) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Solenoid (ositive) Wire #2 (Red/White) Hirschmann lug with Lights ISO 4400/DIN Form in #2 (Negative) in #3 (Ground) in #1 (ositive) " Solenoid (ositive) Wire #1 (Red/White) " Solenoid (Negative) Wire #5 (Red/lack) " Solenoid (Negative) Wire #2 (Red) " Solenoid (ositive) Wire #4 (Red/Yellow) Ground Wire #3 (Green) 5-in Manaplug (Mini) with Lights Single and Double Solenoid Valves ("" and "" Solenoids Reversed for #8 and #9 Spools) Face View of lug Micro Connector valve variations 7, 7 Solenoid (Negative) Wire /3 (lue) Solenoid (ositive) Wire /4 (lack) DESIN Connector M12 pin assignment Standard 1 = Not used DESIN design in 1 and 2 connected Ground Wire /1 (rown) 2 = Not used "" Solenoid (Negative) Wire /1 (rown) "" Solenoid (ositive) Wire /2 (White) 3 = 0V "" Solenoid (ositive) Wire /4 (lack) Ground Wire /5 (Gray) "" Solenoid (Negative) Wire /3 (lue) 4 = Signal (24 V) 5 = Earth Ground p65, dd 29 arker Hannifin Corporation Elyria, Ohio, US
14 ccessories Series D1V Mounting olt Kits olt Kits for use with D1V & Manapaks (D1V*-82 & 70/75 Design, Solenoid Operated & D1V*-60 Design, Non-Solenoid Operated) Number of Manapaks at 44.5mm (1.75") hickness Note: Number of (1.58") thickness K in. K in. K in. K in. K in. KM mm KM mm KM mm KM mm KM mm K in. K in. K in. K in. KM mm KM mm KM mm KM mm K in. K in. K in. KM mm KM mm KM mm K in. K in. KM mm KM mm K in. KM mm ll bolts are SE Grade 8, UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). olt Kits for use with D1V with Explosion roof Coils & Manapaks (D1V*-82 & 70/75 Design) Number of Manapaks at 44.5mm (1.75") hickness Note: Number of (1.58") thickness K in. K in. K in. K in. K in. KM51 50 mm KM mm KM mm KM mm K in. K in. K in. K in. KM mm KM mm KM mm K in. K in. K in. KM mm KM mm K in. K in. KM mm K in. KM mm ll bolts are SE Grade 8, UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). Sandwich Valve Dimensional Data ll D03 Manapak valves (starting with 31 Series) including CM2, COM2, FM2, RDM2 and RM2 measure 40mm (1.58 ) thickness. For additional technical information about Manapak valves, refer to the Manapak Sandwich Valve Section of this Catalog p65, dd 38 arker Hannifin Corporation Elyria, Ohio, US
15 Installation Information Series D1V Fluid Recommendations remium quality hydraulic oil with a viscosity range between SSU (32-54 cst) at 38 C (100 F) is recommended. he absolute operation viscosity range is from SSU ( cst). Oil should have maximum anti-wear properties and rust and oxidation treatments. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate ester or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions, and petroleum oil may be used with NIRILE seals. emperature Recommendation Recommended oil temperature: -7 to +71 C (-20 to +160 F) Filtration For maximum valve and system component life, the system should be protected at a contamination level not to exceed 125 particles greater than 10 microns per milliliter of fluid. (SE Class 4 or better, ISO 16/13). ank Line Surges If several valves are piped with a common tank line, flow surges in the line may cause unexpected spool shift. Detent style valves are most susceptible to this. Separate tank lines should be used when line surges are expected in an application. Recommended Mounting osition Valve ype Detent (Solenoid) Spring Centered Spring Offset Recommended Mounting osition Horizontal Unrestricted Unrestricted Silting Silting can cause any sliding spool valve to stick and not spring return, if held shifted under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Single ass Operation Valve flow ratings are for double pass operation (with equal flow in both paths). When using these components in single pass applications, flow capabilities may be reduced. Consult your local arker representative for details. Flow ath Data D1V Operator Locating pin Operator *Note: On valves with 008 or 009 spool, and/or operators reverse sides. Flow paths remain the same as viewed from top of valve. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve exists when both coils are de-energized, or during a complete shift, as the spool passes through center. Detent and Spring Offset. he center condition exists on detent and spring offset valves only during spool crossover. o shift and hold a detented spool, only a momentary energizing of the solenoid is necessary. he minimum duration of the signal is approximately 0.1 seconds for DC voltages. his position will be held provided the spool center line is in a horizontal plane, and no shock or vibration is present to displace the spool. Single Solenoid. Spring offset valves can be ordered in styles, E, F, H, K and M. Flow path data for the various styles are described in the order chart. Electrical Failure Should electric power fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop simultaneously, machine actuators may continue to function in an undesirable manner or sequence. orque Specifications orque values recommended for the bolts which mount the valve to the manifold or subplate are as follows: #10-24 thread (M5-0.8) torque 5.6 Nm (50 in-lbs) p65, dd 39 arker Hannifin Corporation Elyria, Ohio, US
Directional Control Valves. General Description. Operation. Features
echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or
More informationDirectional Control Valves Series D81V. General Description. Operation. Features. Specifications
echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or
More informationDirectional Control Valves. General Description. Operation. Features
echnical Information Series D61VW General Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are
More informationDirectional Control Valves. Features. Application. Operation
Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold
More informationDirectional Control Valves. Application. Features. Operation
Catalog HY14-2502/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or
More informationDirectional Control Valves. General Description. Operation. Features
echnical Information Series D101VW General Series D101VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are
More informationOperation. D1VW Solenoid Operated Plug-In Conduit Box Style
Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform
More informationDirectional Control Valves. Features. Application. Operation
Catalog HY14-2502/US Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage 4-way valves. hey are available in 2 or 3-
More informationOperation. D1VW Solenoid Operated Plug-In Conduit Box Style
Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform
More informationDirectional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style
Catalog HY14-2500/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which
More informationOperation. D1VW Solenoid Operated Plug-In Conduit Box Style
Catalog HY14-2500/US Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted
More informationOperation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style
Catalog HY14-252/US Introduction pplication arker D3 Series hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3 position. hey are manifold mounted
More informationDirectional Control Valves. Application. Features. Operation.
Catalog HY14-2500/US Introduction pplication Series D101 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or
More informationIndustrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US
LH SECION Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories echnical Information General Description Series D61VW directional control valves
More informationHydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire
ulletin 2544-1/US Introduction pplication arker D1M Series hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3 position styles. hey are
More informationDirectional Control Valves. Application. Features. Operation
Catalog HY14-2500/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or
More informationSérie D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US
Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way
More informationDirectional Control Valves Series D111VW. General Description. Features. Performance Curves
Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional
More informationIndustrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US
LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US echnical Information General Description Series D1VW directional control
More informationDirectional Control Valves. General Description. Features. Specifications
Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position
More informationDirectional Control Valves. Features. Application. Operation
Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and
More informationIndustrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US
Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US Industrial Hydraulic Valves WRNING USER RESONSIILIY FILURE OR IMROER SELECION
More informationIndustrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US
LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US Industrial Hydraulic Valves LH WRNING USER RESONSIILIY FILURE OR IMROER
More informationBulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves
Service Bulletin 91 Design Effective: May 1, 2007 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This
More informationBulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves
Service Bulletin 91 Design Effective: May 1, 2007 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This
More informationDirect Operated Proportional DC Valves
echnical Information Direct Operated roportional DC Valves Series D1F and D3F General Series D1F and D3F directional control valves of nominal sizes NG6 (CEO 3) and NG10 (CEO 5) respectively, provide variable
More informationBar 35 PSI 500. Pressure Drop L/M GPM. Flow
NF D3 O E R I N G N D E C H N I C L D RINGS Maximum Flow... See Chart Maximum Operating ressure (, and orts)... 3 ar ( SI) Maximum ank Line ressure... 13 ar (1 SI) Mounting attern... ISO 441--3-4-, NF-D3
More informationDirectional Controls
VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................
More informationDirectional Controls
Vickers Directional Controls Mechanical ctuators Directional Control Valves Directional Control Valves 310 bar (4500 psi) Flows to 114 l/min (30 USgpm) NF D05, ISO-4401-05 DG1V4-01**-10 Knob Operated DG17V4-01**-10
More informationDirectional Control Valves. General Description. Features. Specifications
echnicl Informtion Generl Description directionl control vlves re high performnce, 5-chmer, direct operted, wet rmture, solenoid controlled, 3 or 4-wy vlves. hey re ville in 2 or 3-position nd conform
More informationPilot-Operated Directional Control Valves Series D3 - D11
Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow
More informationDirectional Control Valve Series D1VW
Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options
More informationUSA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:
SECIFICIONS D05H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol
More informationDirectional Controls
Vickers Directional Controls ilot Operated Directional Valves DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000
More informationBankable Control Valves
Hydraulics ankable Control Valves Catalog 3123/US Catalog 3123/US Contents ankable Control Valves WRNING FILURE OR IMROER SELECION OR IMROER USE OF HE RODUCS ND/OR SYSEMS DESCRIED HEREIN OR RELED IEMS
More informationHigh Pressure, Subplate Mounted Directional Control Valves
ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H05 5 gpm (19 L/min) nominal 8000 psi (560 bar) Sliding-spool H05 valves provide true four-way control in a simple
More informationDirectional Control Valve
Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows
More informationPilot Operated Directional Control Valves Series D31DW, D41VW - D111VW
Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have
More informationDirectional Control Valve Series 4D01 (DENISON)
Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift
More informationUSA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:
DIRECIONL VLVE OERION Directional Valve Features, Selection and Operating Recommendations CONC INFORMION US Headquarters Dynex/Rivett Inc. 770 Capitol Drive ewaukee, WI 3072 U.S.. el: 262-69-2222 FX: 262-69-032
More informationUSA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:
SECIFICIONS D0H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol Drive
More informationPilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW
Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3
More informationChapter 2: Directional Control Valves
Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically
More informationHigh Pressure, Subplate Mounted Directional Control Valves
ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H03 5 gpm (19 L/min) nominal 10 000 psi (700 bar) H03 valves are rated for 5 gpm (19 L/min) nominal flow at pressures
More information"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE
"G" SRIS SHOCKLSS Y NOID ORD DIRCIL VLVS G-DSG-1/3 (1/, 3/) "G" SRIS SHOCKLSS Y NOID CROLLD ILO ORD DIRCIL VLVS G-DSHG-/ (1/, 3/) Mounting Up to 5 Ma (33 SI), 5 L /m in (.1 U.S.GM) ub. C-5 DIRCIL CROLS
More informationSolenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.
Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid
More informationManapak Sandwich Valves. General Description
echnical Information Series RM General Description RM Series relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. With D3 size, they can also be configured
More informationD07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:
GENERL FEURES SNDRD FEURES High ressure/ High Flow: 65 gpm/ psi ilot Operation: Main spool controlled by D0 solenoid pilot valve- allows for addition of modular valves to reduce shifting shock. Oil Immersed,
More informationUSA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:
SPECIFICAIONS D05 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONAC INFORMAION USA Headquarters Dynex/Rivett
More informationMonobloc and Sectional Directional Control Valves
Monobloc and Sectional irectional Control Valves 200 - - 991210 - - 03/09.2015 1/220 8 Sectional directional control valves HS11 8 valves... p.101 Contents 8.1 General specification 101 8.2 imensional
More informationPilot Operated Directional Valves
ilot Operated Directional Valves Catalog DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) NF D10, ISO-4401-10,
More informationSolenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)
Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM
More informationSeries Shockless Type Solenoid Controlled Pilot Operated Directional Valves
Solenoid Controlled ilot Operated Directional Valves Electronic Circuit X Specifications Descriptions G-DSHG-4-3C - - - -/9 G-DSHG-6-3C - - - -/9 Max. Flow /min (U.S.GM) 16 (4.3) (66.1) 1 1 Max. Operating
More informationEManually Operated Directional Valves
DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM-- -
More informationPressure Control Valves Series R. General Description. Specifications. Flow Data
Catalog Y14-2502/US Technical Information Series R General Description Series R direct relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. Specifications
More informationDirectional Controls
VICKERS Directional Controls DG3V-7, 20 Series, ilot Operated DG5V-7, 40 Series, Solenoid Controlled, ilot Operated ISO 440 Size 07 ypical Section DG5V-7-2C Spring-Centered Valve Example Basic Characteristics
More informationProportional Pressure Reducing Valve Series D1FV
Characteristics roportional ressure Reducing Valve Series D1FV he proportional pressure reducing valves series D1FV are available with and without onboard electronics (OE). D1FV OE he digital onboard electronics
More informationDirectional Control Valve Series D3W Soft Shift
Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this
More informationDirectional Control Valves
Frequently sked Questions Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It provides
More informationANTI-SHOCK DIRECTIONAL CONTROL VALVES
ACTUATED, DIRECT OPERATED TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit)
More informationMonobloc and Sectional Directional Control Valves
Monobloc and Sectional Directional Control Valves 200--991210-N-03/09.2015 03 / 10.04 1/220 11 Sectional directional control valves HDS30 Contents 11.1 General specifications 197 11.2 Dimensional data
More informationMonobloc and Sectional Directional Control Valves
Monobloc and Sectional Directional Control Valves motion and progress 200 991210 03 / 10.04 1/220 HDS11 8 Sectional directional control valves HDS11 8 Standard valves................................................................
More informationDirectional Control Valves
Frequently sked Questions N-1 Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It
More informationDirectional control valves NG6...NG32 D03...D10 6
Directional control valves NG6...NG32 D03...D10 6 DIRECIONL CONROL VLVES 1 Index DO3 (NG6) age 2 to 22 D05 (NG10) age 23 to 42 D07 (NG16) age 43 to 54 D08 (NG25) 3000 SI age 55 to 65 D08 (NG25) 4600 SI
More informationDFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>
DFE1 Ordering codes Description example : Diverter valve DFE1/3 18 ES - W 22-12VDC - SE - 1. 4. 5. 3. 5. 2. Valve is supplied painted as standard, with one coat of rimer black antirust paint II 5.
More informationD05 Directional Control Valves
Engineering D05 Directional Control Valves WFDG4S*4-01, 60 Design Wet Armature Solenoid Operated Max Pressure up to 248 Bar (3600 psi) Same Day Shipments www.fluidynefp.com Table of Contents Basic Characteristicts...2
More informationRA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.
R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to
More informationRA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section
4/3, 4/2 and 3/2-Way Directional Valves Model.WE.../.D, Series 3X with Wet in DC Solenoids Size (D )... 3 SI... 2 GM (2 ar) (8 L/min) RA 23 37/6.98 Replaces: 2.96 Features: Direct solenoid operated directional
More informationEMechanically Operated Directional Valves
E DIRECIONL CONROLS Cam Operated Directional Valves hese valves may be used to shift the direction of oil flow by depressing the spool by way of a cam. Specifications Max. Operating Max. -Line Max. Flow
More informationCartridge Valves Technical Information Directional Valves DCV 03
OVERVIEW DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position directional valves
More informationHydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Hydraulic ower Units D, H, V-ak and V-ak Low rofile Series HY28-2661-CD/US
More informationDirectional Control Valve Series D3W (Parker), 4D02 (Denison)
Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are
More information3/2 and 4/2 directional seat valves with solenoid actuation
1/16 3/ and 4/ directional seat valves with solenoid actuation RE 047-XH-B/01.10 Replaces: 09.07 ype E-.SE 6...XH ype W-.SE 6...XH Size 6 Component series 6X Maximum operating pressure 40 bar Maximum flow
More informationVSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED
NFPA SIZE D10 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may be reduced from that shown if a three-way circuit (half circuit) is used,
More informationMDT. Monoblock directional control valves MDT - Directional control valve
Monoblock directional control valves - Directional control valve efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES echnical data Nominal flow 35 l/min 9. US gpm Nominal
More informationUSA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:
SPECIFICATIONS D03 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONTACT INFORMATION USA Headquarters Dynex/Rivett
More information4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768
/- and /-Way roptional Directional Control Valve Direct Operated, Model WR (Series X) Size 6 and... 6 SI ( bar).... GM (9 L/min) R 9 /6.98 R 9 /6.98 Replaces:.9 Characteristics: F the open loop control
More informationDirectional Controls
Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed
More informationUSA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:
SPECIFICIONS D08H Pattern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol
More informationCable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308
Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also
More informationDirectional Controls
Vickers Directional Controls Solenoid Operated Directional Valves DGV-3 flows to 80 l/min (1 USgpm), * design DGV-3S flows to 0 l/min (10. USgpm), * design ISO 01, size 03; NSI/93.7M-D03 Rev 0/98 G-C-01
More informationVickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)
Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................
More informationBST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.
Specifications hreaded Connection Mounting BS-- - - - -47 BS-06- - - - -47 BS-0- - - - -47 BSG-- - - - -47 BSG-06- - - - -47 BSG-0- - - - -47 BS / BSG- / 06 / 0 hreaded Connections / Mounting Specifications
More informationEManually Operated Directional Valves
DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM--B -
More informationMounting and Assembly of Sandwich Bodies
Mounting and ssembly of Sandwich odies Mounting of ISO 0 (CEO ) Sandwiches Many of Sun s ISO 0 (CEO ) sandwich bodies are designed for multi-functional use to permit maximum circuit flexibility. With the
More information3/2 and 4/2 directional seat valves with solenoid actuation
1/16 /2 and 4/2 directional seat valves with solenoid actuation RE 22047-XH-B2/09.12 Replaces: 05.12 ype E-.SE 6...X... ype W-.SE 6...X... Size 6 Component series 6X Maximum operating pressure 420 bar
More informationPilot Operated Pressure Relief Valve Series R5V (Denison)
Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps
More informationAccessories Series PSB. Specifications
Catalog HY14-252/US Technical Information General Description electrohydraulic pressure switches are high performance devices that provide an electrical signal when sensed pressure rises above or falls
More informationHigh Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves
igh Response ype roportional Electro-ydraulic s igh response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVD. Direct
More informationProportional pressure reducing valve of 3-way design
Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Electric Drives and Controls Hydraulics Linear Motion and ssembly echnologies neumatics
More informationNG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.
Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application
More information4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)
4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ) RE 18301-12 Edition: 02.2016 Replaces: 07.12 07.2012
More informationRELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled
RELIEF VALVES Remote ontrol / Direct ype ilot Operated / Solenoid ontrolled Up to 5 Ma (3630 SI), 0 L /m in (06 U.S.GM) ub. E-00 Remote ontrol Relief Valves... age 3 his valve is used as a remote control
More informationD03 FluiDyne Valves. ENGINEERING DATA
ENGINEERING D D3 FluiDyne Valves 4 Way, and 3 Postion Solenoid Operated Variety of Voltage and Spool Configurations Same Day Shipments 1 Month Warranty www.fluidynefp.com D3 FluiDyne Valves: 4 Way, and
More informationMonoblock directional control valves DL - Directional control valve
Monoblock directional control valves DL - Directional control valve DL Before use, carefully read the GENERAL INSRUCIONS FOR USE OF DIRECIONAL CONROL VALVES 398SMD008I00-06-2-208 DL echnical data Nominal
More informationp max (see table of performances) Q max (see table of performances) MD1K MD1KD bar
41 510/107 ED EXLOSION-ROOF VERSION SOLENOID OERED DIRECIONL CONROL VLVES in compliance with EX 94/9/CE SERIES 21 MD1K-MD1KD ISO 4401-03 (CEO 03) E44K-E44KD CEO 05 E074K-E074KD ISO 4401-07 (CEO 07) E54K-
More informationSECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES
SECION ILE HEC2003/2004 SERIES SERVO VLVE SYSEM he HEC2003/2004 Series Servo System features a high response servo valve, a manifold mounted filter, and three different mechanical mounting options. he
More informationMonobloc and Sectional Directional Control Valves
Monobloc and Sectional Directional Control Valves motion and progress 1/220 10 Sectional directional control valves HDS20 Contents 10.1 General specifications 177 10.2 Dimensional data 178 10.3 erformances
More informationNG06. General Size NG6 NG10 Design
Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve
More informationMonobloc and Sectional Directional Control Valves
Monobloc and Sectional irectional Control Valves motion and progress 200--991210-N-03/09.2015 - - - - 03/09.2015 1/220 8 Sectional directional control valves HS11 8 Standard valves... p.101 Contents 8.1
More information