1 E LIGHT INDUSTRIAL TANKS ULC-S601, ULC-S602, ULC-S652 BUILT TOUGH TO HANDLE ANY JOB Tough and durable, our light industrial tanks will meet your various storage requirements S E W UP TO 10 WARRANTY A R R A YEARS N T Y C T E R I C A T I F
2 STATIONARY TANKS - GENERAL SPECIFICATIONS ASTM A 1011 Steel NPT female threaded openings Capacity ranging from 125 to 2000 Gallons Double wall tanks Each tank is manufactured and controlled, tested and labeled in accordance with ULC-S601 standard for flammable and combustible liquids ULC-S601 DOUBLE-WALL VACUUM MONITORED TANK Capacity of liters High quality emergency vent Shown: L + ladder 8 openings on top Integral spill box containment in accordance to ULC-S663 Available hot dipped galvanized steel ladder and fill platform, on-site installation required Available hot dipped galvanized steel staircase and fill platform. The staircase can be mounted on the right, the left or in center of the fill platform without any additional cost and component; on-site installation required Mounting brackets for addition of pump, dispenser, hose retriever and emergency stop on opposite end of the ladder or staircase white polyurethane paint Shown: L + stairs
3 ULC-S601 DOUBLE-WALL VACUUM MONITORED TANK Capacities ranging from 570 liters to liters High quality emergency vent 6 openings on top Integral spill box containment in accordance to ULC-S663 Optional hot-dipped galvanized step available on 38.5 and 50.5 diameter tanks; on-site installation required Shown: L + step white superior polyurethane 10+ paint also available ULC-S601 DOUBLE-WALL INTERGRALLY CONTAINED TANK Capacities ranging from liters to liters The integrity of the primary tank is verified by a mechanical leak detector Equipped with a visual leak indicator gauge Two (2) high quality emergency vents Only one (1) atmospheric vent required 6 openings on top Integral spill box containment in accordance to ULC-S663 Optional hot-dipped galvanized step; on-site installation required. Shown: L Optional electronic leak detector
4 AUXILIARY TANKS - GENERAL SPECIFICATIONS ASTM A 1011 Steel NPT female threaded openings Capacity ranging from 50 to 500 Gallons Double wall tanks Each tank is manufactured and controlled, tested and labeled in accordance with ULC-S602 standard for flammable liquids and lubricant oil ULC-S602 DOUBLE-WALL HORIZONTAL TANK WITH SECONDARY CONTAINMENT Capacities ranging from 227 liters to liters Vacuum leak detection monitoring system can be replaced on site by a liquid leak detector (mechanical or electronic) Up to eight (8) openings on top Shown: L Steel surface is phosphate washed and coated with ULC-S602 DOUBLE-WALL VERTICAL TANK Capacities available from 227 liters to liters VCC MODELS (double wall secondary containment) The integrity of the primary tank is verified by a mechanical leak detector Equipped with a visual leak indicator gauge Up to eight (8) openings on top Optional electronic leak detector VCD MODELS (double wall, vacuum monitored) Shown: L Up to eight (8) openings on top white superior polyurethane 10+ paint
5 ULC-S602 DOUBLE-WALL VACUUM MONITORED OBROUND TANK Available in capacities of 850 liters, liters and liters Eight (8) openings on top Shown: 1000 L USED OIL TANKS - GENERAL SPECIFICATIONS ASTM A 1011 Steel NPT female threaded openings Available in 250 Gallons, 500 Gallons and 1000 Gallons Double wall tanks Each tank is manufactured and controlled, tested and labeled in accordance with ULC-S652 standard for used oils ULC-S652 DOUBLE-WALL VACUUM MONITORED HORIZONTAL USED OIL TANK Available in capacities of 1 135L, 2 275L and 4 550L. High quality emergency vent Internal two (2) inches suction pipe Pumper truck camlock 2 connection with dust cap installed inside spill box Drip pan installed inside spill box Six (6) openings on top Shown: 500 Gal + stairs option Optional hot-dipped galvanized step available, on-site installation required white superior polyurethane 10+ paint
6 TANK CAPACITY AND DIMENSIONS Granby Storage Tanks offers light industrial tanks of different capacities for the storage of fuel, diesel, kerosene, lubricating oil and used oil. Tank weight vary according to the chosen model and options. Refer to the table below or to our website for further details. DOUBLE WALL STATIONARY TANKS, VACCUM PHOSPHATE CLEANED MODELS WITH WHITE POLYURETHANE PAINT, ULC-S601 LISTED NCAA mm NCAA mm NCAA mm NCAA mm NCAA mm NCAA mm NCAA mm SANDBLASTED MODELS WITH WHITE POLYURETHANE PAINT, ULC-S601 LISTED SCAA mm SANDBLASTED MODELS WITH WHITE SUPERIOR POLYURETHANE PAINT, ULC-S601 LISTED SCAA mm SCAA mm SCAA mm SCAA mm SCAA mm SCAA mm SCAA mm DOUBLE WALL VERTICAL DAY TANKS CLOSED SECONDARY CONTAINMENT TANK, ULC-S802 LISTED VCC22050NCAA ,75 2.5mm VCC22100NCAA mm VCC22150NCAA mm VCC22200NCAA mm VCC22250NCAA mm VCC22300NCAA mm VCC22500NCAA mm DOUBLE WALL, SANDBLASTED, WHITE POLYURETHANE 10PLUS ULC-S602 VCD22050PCAA ,75 2.5mm VCD22100PCAA mm VCD22150PCAA mm VCD22200PCAA mm VCD22250PCAA mm VCD22300PCAA mm VCD22500PCAA mm DOUBLE WALL HORIZONTAL DAY TANKS CLOSED SECONDARY CONTAINMENT TANK, ULC-S602 LISTED 3002C222NCAA mm C222NCAA mm C222NCAA mm DOUBLE WALL HORIZONTAL DAY TANKS CLOSED SECONDARY CONTAINMENT TANK, ULC-S602 LISTED 125F22NCAA mm F22NCAA mm F22NCAA mm C222NCAA mm C232NCAA mm C242NCAA mm DOUBLE WALL STATIONARY TANKS, WITHOUT VACUUM MONITORING INTEGRALLY CONTAINED MODELS, ULC-S601 LISTED 3023D242NCAA mm D222NCAA mm DOUBLE WALL HORIZONTAL DAY TANKS CLOSED SECONDARY CONTAINMENT TANK, ULC-S602 LISTED 3011W222PCAA mm W242PCAA mm W222PCAA mm For more information, please contact our main office at 1020 André-Liné Street Granby, Quebec J2J 1J9 sales@granbyindustries.com W granbyindustries.com * Contact your representative for more information on the different additional accessories available. TNK.GBYINDUS-ENC-0218
.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.
Shoal Lake Intake Fuel Storage and Delivery System Rehabilitation Page 1 of 10 1. GENERAL 1.1 Scope.1 The following statement generally describes the scope of work covered by this Section. All tank volumes
More informationModel Model Model 3650 Model 3614
Model 3601 Model 3662 Model 3650 Model 3614 Model 3675 Portable used fluid handling equipment and fuel caddies Collection equipment pressurized (self-evacuating)....... 170 Upright drains.....................................
More information7. Protection System Testing
MANUAL FOR INSTALLATION AND MONITORING OF UNDERGROUND STORAGE TANKS WITH FACTORY INSTALLED ANODES 1. SCOPE Manufactured by: Granby Industries 1020 André-Liné Granby, Québec, Canada, J2J 1J9. Telephone:
More informationACCESSORIES. Adaptor for ex100 spin-on ex100 UL/ULC Spin-on filter complete 10 µm, 17 gph UL/ULC Spin-on element 10micron for EX200 UL/ULC
ACCESSORIES SPIN-ON FILTER: 10 MICRON, 17 GPH WITH NPT PIPE CONNECTIONS (40 PSI MAX) The spin-on filter helps to increase your heating system s efficiency and to protect your furnace s burner. The element
More informationDual wall sub-base diesel fuel tanks -
Specification sheet Dual wall sub-base diesel fuel tanks - 10-125 kw generator sets Description Cummins offers two series of fuel tanks (basic series and regional series) for the 10~125 kw diesel generator
More informationFABRICATION/ WELDING PROCESSES
PAGE NO. PLANT INFORMATION 4 FABRICATION/ WELDING PROCESSES 5 GREER BUILDING ADDITION SUMMER 2015 6 BLAST AND PAINT FACILITY SUMMER 2015 7 OBROUNDS UL/NON UL 8 OBROUND ACCESSORY KIT 9 ABOVE GROUND SINGLE-WALL
More informationFUEL TANKS FUEL TANKS
FUEL TANKS FUEL TANKS Meridian is the proud innovator and largest North American manufacturer of all-welded, SmoothWall hopper bins, with offices and production facilities across the continent. Since the
More informationPEI/RP Recommended Practices for Installation of Bulk Storage Plants
PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Sound Enclosure and Subbase Fuel Tank Package Applicable to the following models: KD800 - KD2500 (includes KD1250-A) Level 1 Sound Enclosure with Lift Base Sound Level
More informationPETROLEUM STORAGE. Used Oil and Fuel Oil Storage Double Wall Above Ground Storage Single Wall Above Ground Storage Mobile Petroleum Service Tanks
PETROLEUM STORAGE Used Oil and Fuel Oil Storage Double Wall Above Ground Storage Single Wall Above Ground Storage Mobile Petroleum Service Tanks 01 EXCELLENCE IN STEEL FABRICATION FOR MORE THAN A CENTURY
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Aluminum Sound Enclosure and Subbase Fuel Tank Package Applicable to the following models: KD800 - KD2500 Level 1 Sound Enclosure with Lift Base Sound Level 1 Enclosure
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2008 edition of NFPA 30A, and the 2006 International Fire Code (IFC). Please
More informationPETROLEUM S T O R A G E 01
PETROLEUM STORAGE 01 Cradle tanks affordable ulc listed storage options excellence in steel fabrication for more than a century Today, environmental and safety concerns demand that special care be taken
More informationANNUAL UST SYSTEM INSPECTION CHECKLIST
APPENDIX A-3: SAMPLE FORM FOR ANNUAL UNDERGROUND STORAGE SYSTEM INSPECTION CHECKLIST Page 1 ANNUAL UST SYSTEM INSPECTION CHECKLIST Facility ID# Facility Name/Address Qualified Technician Signature Date
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that
More information2 Fluid Level Management
2 Fluid Level Management Introduction.................................... 2-3 REN Oil Level Regulator........................ 2-5 REN Slow Flow Meter.......................... 2-9 Slow Flow Meter Remote
More informationTank Filling Systems for Petroleum Products
for Petroleum Products Insight Onsite for Petroleum Products Page 2 What is it used for? Generally used with aboveground storage tanks, although some underground uses as well. What is it? An easy means
More informationDEFENDER SERIES SPILL CONTAINERS SPILL CONTAINERS HIGHLIGHTS SPECIFICATIONS
DEFENDER SERIES Defender Series five gallon spill containers combine years of knowledge and experience in forecourts across the globe to represent the best defense in spill containment. Proactively protecting
More informationOIL CONTAINERS
OIL CONTAINERS WWW.TRICOCORP.COM introducing OIL CONTAINERS providing a simple, easy-to-use and error-free solution to store, identify, transport and dispense lubricants Spectrum Oil Containers offer users
More information3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.
TITLE 41: FIRE PROTECTION CHAPTER I: OFFICE OF THE STATE FIRE MARSHAL PART 180 STORAGE, TRANSPORTATION, SALE AND USE OF GASOLINE AND VOLATILE OILS SECTION 180.20 ABOVEGROUND STORAGE DISPENSING Section
More informationLEAK DETECTION INTERSTITIAL MONITORING
LEAK DETECTION INTERSTITIAL MONITORING What is Interstitial Monitoring? A monthly Monitoring Method for double walled and integral secondary containment tanks and piping systems. A method that detects
More information2062 ½ NPTM x ¼ NPTF bushing ½ NPTM x 3/8 NPTF bushing ½ NPTM x 3/8 NPTF bushing
stationary grease pump packages pumpmaster 3, 3+3 and 6 3 Model 306000 PumpMaster 3 grease pump package for 120 lb kegs 302 PumpMaster 3 high pressure grease pump with bung adapter 1936 120 lb keg cover
More informationLube PUMP PACKAGES. pumpmaster 3+3 and 6
stationary grease pump packages pumpmaster 3+3 and 6 Model 336000 PumpMaster 3 + 3 grease pump package for 120 lb kegs 332 PumpMaster 3 + 3 high pressure grease pump with bung adapter 1936 120 lb keg cover
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Packages Weather Enclosure Sound Enclosure Applicable to the following models: 650/750REOZDB Kohler enclosures protect
More informationFarm & Residential Tanks Angle skids
Farm & Residential Tanks Angle skids Multi-purpose, convenient, and economical fuel storage Each tank tested to ensure quality Engineered for strength and dependability Made with U.S. steel Tank listed
More informationSTATIONARY GREASE PUMP PACKAGES. Model PM grease pump package for 120 lb kegs lb drum cover 966 Follower plate for 400 lb drum
STATIONARY GREASE PM 3+3 AND 6 Model 336 000 PM 3 + 3 grease pump package for 120 lb kegs 332 PM 3 + 3 high pressure grease pump with bung adapter 1936 120 lb keg cover 964 Follower plate for 120 lb keg
More information(Please type or use black ink)
(Please type or use black ink) PNIPUG ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT NOTICE OF PROPOSED UST NEW INSTALLATION OR UPGRADE (Use a separate form for each separate place of operation) Date of
More informationTHE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS
THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com
More informationProvide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.
UNDERGROUND STORAGE TANK SYSTEM INSTALLATION/UPGRADE SUPPLEMENT For use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: California Fire (CFC); Chapter 6.7, Health
More informationEnvironment Canada (EC) Storage Tank System Identification Form
Environment Canada (EC) Storage Tank System Identification Form Identification of storage tank systems for the purpose of the Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations
More informationFUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System
FUEL DISPENSING SYSTEMS Component Details SE-27 12V DC - 15 GPM Metered Tank-top Dispensing System 12V DC Electric Pump - 1 Inlet - 3/4 Outlet 3-Wheel Mechanical Meter 1 Automatic Nozzle, Swivel & Hose
More informationAbove Ground Oil Tanks
Helping you identify and manage risk Above Ground Oil Tanks In many regions across Canada particularly in Québec and the Atlantic provinces above ground oil tanks are still being used to heat institutional
More informationPROFESSIONAL GRADE FUEL TRANSFER PUMPS CATALOG
PROFESSIONAL GRADE FUEL TRANSFER PUMPS 2014-15 CATALOG ENGINEERED TO DELIVER Extended Duty Cycles PRO20-012 Get more done in less time with the powerful PRO20-012 Extended Duty Cycle exceeds the industry
More information9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide
- Design Guides A. SITE PLANS: Provide existing condition, removal plan, and proposed installation site plans for all tanks. Plans must include the following: 1. Dimensions of tank and any structural pads.
More informationNew Tank Installations. Peter Rollo
New Tank Installations Peter Rollo New Tank Installations What tanks are regulated? All tanks with a capacity greater than 1,100 gallons Commercial tanks, other than heating fuel tanks, with a capacity
More informationTank Filling Systems. for Petroleum Products
Tank Filling Systems for Petroleum Products Tank Filling Systems for Petroleum Products page 2 What Is It Used For? Generally used with aboveground storage tanks, although some underground uses as well.
More information215 Gallon Waste Oil Tank With Metering Pump Installation Instructions
215 Gallon Waste Oil Tank With Metering Pump Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...
More informationMODEL C-COBRA SERIES CONVERTER REPAIR KIT INSTRUCTIONS
MODEL C-COBRA SERIES CONVERTER REPAIR KIT INSTRUCTIONS Important: Any maintenance, service or repair should be performed by trained and experienced service technicians. Proper tools and equipment should
More informationReliant Series Systems Fuel Tanks DAY TANKS FILTRATION TANKS SPECIALTY TANKS
Reliant Series Systems Fuel Tanks DAY TANKS FILTRATION TANKS SPECIALTY TANKS The Simplex Reliant Series is the latest design expression of a seventyyear history of innovation and reliability from the originator
More informationDOUBLE DRUM OPERATIONS MANUAL 2017 VERSION C
DOUBLE DRUM OPERATIONS MANUAL 2017 VERSION C DOUBLE DRUM OPERATIONS MANUAL (Version C) Issue Date: August 2017 PLEASE READ BEFORE USING. SEI INDUSTRIES LTD. 7400 Wilson Avenue Delta, B.C. Canada V4G 1H3
More informationUser and maintenance instructions. Fluid evacuator plus. Model MV7201. Date of issue November Form number Version 2
User and maintenance instructions Fluid evacuator plus Model MV7201 Date of issue November 2017 Form number 801672 Version 2 Contents Safety........................... 2 Explanation of signal words for
More informationFUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System
FUEL DISPENSING SYSTEMS Component Details SE-47 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter in Cabinet 1 Automatic
More informationFluid Distribution Header
Fluid Distribution Header Application Guide A Pre-Engineered Subsystem Pre-engineered subsystems available in weeks, not months. Field-tested design ensures optimum system performance. Versatile manifold
More informationT60 REGULATOR REPAIR KIT INSTRUCTIONS
T60 REGULATOR REPAIR KIT INSTRUCTIONS This PPI covers the repair of Series I and II T60 regulators using either a minor or major repair kit. Important: Any maintenance, service or repair should be performed
More informationTECHNICAL DATA. Q= C v P S
1 of 9 1. DESCRIPTION The Viking Model E-1 Deluge Valve is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction
More informationDIAPHRAGM METERING PUMPS
JANUARY 2004 DIAPHRAGM METERING PUMPS JN Series 5 Models 1-7 GPH MF Series 11 Models 5-75 GPH MH Series 5 Models 96-180 GPH Simple, Rugged and Accurate Designed For Continuous Heavy Duty Service Manufacturing,
More informationTECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)
1 of 9 1. DESCRIPTION The Viking 2 (DN50) is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction sprinkler
More informationPump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min
Pump Manual Model Numbers: SP240VDFS57LPM SP240VDFS80LPM Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min Copyright: Scintex Fuel Depot 2012[Type text] Page 1 WARNING:
More informationCongratulations PRE-OPERATION SETUP
Congratulations on the purchase of your new ProVac Industrial Pumpout Station. Your new ProVac has been manufactured with the best quality components to give you year after year of trouble free service.
More informationInspector's Initials: Tank Owner or Agent Signature: Title: Date:
STATE OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF UNDERGROUND STORAGE TANKS 4 TH Floor, L & C Tower 401 Church Street Nashville, TN 37243-1541 UST OPERATIONS INSPECTION Mo /Day
More informationPORTABLE UNITS PORTABLE GREASE PACKAGES FOURTH DIGIT. Hose Length. Model Model 1307
PORTABLE GREASE PACKAGES NUMBERING SYSTEM FIRST THREE DIGITS FOURTH DIGIT FIFTH DIGIT SIXTH DIGIT Pump Model Hose Length Dolly Filter Regulator Combo with Gauge 301 402 303 305 35 lb pail unit, 55:1 PM3
More informationTable of Contents WARRANTY
H.E.R.O. Industries a division of Middlefield Bancorp Limited 2719 Lake City Way, Burnaby, B.C., Canada Phone: ( 604 ) 420-6543 Fax: ( 604 ) 420-8725 Toll Free: 1-800-494-4376 E-mail: sales@hero.ca Website:
More informationPREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843
BID ADDENDUM NO. 1 PROJECT: PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843 LABELLA PROJECT NO: 2160128 DATE: FEBRUARY 11, 2016 FROM: LaBella
More informationConstruction Maintenance Support Equipment Package
Construction Maintenance Support Equipment Package Construction Maintenance Support Equipment Package B&D offers a broad range of maintenance support equipment that will put your construction equipment
More informationSlide In Vacuum Tank Price List 48 Standard Models
Slide In Vacuum Tank Price List 48 Standard Models 300, 450, 600, 800, 995, 1200 & 1500 Gallon Capacities Rear Engine Side Engine Side Engine Transverse January 2018 SC Model Slide In Vacuum Tank Standard
More informationRULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX
RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted 2-5-75 (Amended 9-15-75, 8-3-77, 9-2-80, 12-17-91, 2-2-95, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION:
More informationNew UST Installation Inspection Checklist
Nebraska State Fire Marshal Fuels Division - FLST Section 246 South 14 TH Street - Lincoln, NE 68508-1804 (402) 471-9466 New UST Installation Inspection Checklist (Petroleum or Hazardous Substances) Inspection
More informationUltra-Matic Air Valve System
Ultra-Matic Air Valve System Efficient Pumps, Competitive Upgrades and Accessories U2 Plastic Pumps Metallic Pumps Specialty Pumps Upgrade Kits Accessories Diaphragms Ultra-Matic Air Valve Technology Simple.
More informationEarthsafe Systems, Inc. Page 1
ESS.WP.531. YQA Fuel Transfer Your Questions Answered (47) Fuel Transfer Systems earth safe Fuel Systems for Critical Power. 5.1 What types of pumps are used for fuel transfer? Fuel transfer pumps are
More informationFUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System
FUEL DISPENSING SYSTEMS Component Details SE-37 120V AC - 20 GPM Metered Tank-top Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter 1" Automatic Nozzle, Swivel
More informationTECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)
Flow Control 500a DESCRIPTION The Viking 1-1/2 is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The can be used to facilitate manual or automatic on/off
More informationDEF Drum & IBC. Closed Systems. For Customer / End-User
DEF Drum & IBC Closed Systems For Customer / End-User Container Valve Systems CLOSED, SEALED & SECURE www.industrial.micromatic.com DEF Distribution CLOSED, SEALED & SECURE Ways to Go, Sizes & Recommended
More informationBlue Line. Wet/Dry Vacuums - for safer, cleaner and more productive job sites & facilities
Blue Line Wet/Dry Vacuums - for safer, cleaner and more productive job sites & facilities Automotive General Facility Maintenance Building and Constriuction Vacuums that work as hard as you do. For hands-on
More informationGeo-Prime Tank U.S. Patent Number 8,544,282
www.geo-flo.com Geothermal and Hydronics Specialists Installation, Operating, and Maintenance Manual Part # 3487 Rev. 03JUL2014 Geo-Prime Tank U.S. Patent Number 8,544,282 Geo-Flo Products Corporation
More informationES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number
ES-301-1.01 Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number ES-301-1.01 Document Owner: John Hambright 1) Activity Description: Fueling Aircraft, Vehicles, and Auxiliary
More informationPortable Equipment High-Pressure Heavy-Duty Grease Pumps
High-Pressure Heavy-Duty Grease Pumps 917 346P 987 Series 20 50:1 Air-Operated Double Acting The following models contain Lincoln s high pressure Series 20 grease pumps. Model 917 120 lb. Drum Will dispense
More informationE8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions
E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions Polypropylene SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Aluminum and Steel and Subbase Fuel Tank Package All Generator Set,, and Fuel Tank Options are UL 2200 Certified. Available Approvals and Listings - UL 2200 Listing
More informationNEW! BOOSTER PUMPS. HBP/HBPS series 4" horizontal booster pumps. booster pumps
HBP/HBPS series 4" horizontal The HBP/HBPS Series Booster Pumps are the most durable available. The patented SignaSeal floating impeller design minimizes thrust loads, allowing for continuous operation
More informationTECHNICAL DATA 1-1/2 (dn40)
July 1, 2011 Deluge Valves 209a DESCRIPTION The Viking Model E-3 1-1/2 Deluge Valve is a quick-opening, differential type flood valve with a rolling diaphragm clapper. The deluge valve is used to control
More informationPROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES. Civil Engineering Sector Labour-Management Health and Safety Committee
PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee September 2018 PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES 1.0
More informationSelf Bunded Storage & Dispensing Solutions for Petroleum Products
Self Bunded Storage & Dispensing Solutions for Petroleum Products www. LIQUITAINER Containerised Self Bunded Tanks - Design Features Roof with curved radius - NO pooling of water Designed and Approved
More informationNorth Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section
North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section To discover a release before a major contamination incident occurs Required
More informationINDUSTRIAL SERVICE TANKS
INDUSTRIAL SERVICE TANKS Glendale Service s are designed and built with you in mind. We ensure every PWT and VST Series tank is tailored to load quickly and efficiently. Over 25 years of experience, certified
More informationTRADE EXPERIENCE LOG BOOK CANADIAN PETROLEUM CONTRACTORS ASSOCIATION. Petroleum Mechanic Training & Certification
CANADIAN PETROLEUM CONTRACTORS ASSOCIATION Petroleum Mechanic Training & Certification TRADE EXPERIENCE LOG BOOK PM1 - Service & Maintenance PM2 - Underground Installation PM3 - Aboveground Installation
More informationBulk Supply Station. HSAUSA Bulk Supply Station HSAUSA
HSAUSA HSAUSA The HSAUSA provides a simple alternative to cartridges for high volume applications, while cutting ink costs up 50%. Each gravity fed system consists of a 1-liter ink bottle that feeds up
More informationALL ENGINES APPROVED OIL EVACUATION EQUIPMENT
Date: March 2001 Order No.: Supersedes: S-SI-58.00/118 > Group: 58 SUBJECT: ALL ENGINES APPROVED OIL EVACUATION EQUIPMENT The purpose of this Service Information is to inform dealers that Approved Oil
More informationWorld Class Fluid Storage & Handling Solutions
World Class Fluid Storage & Handling Solutions www.fluidall.com 800.849.0591 sales@fluidall.com Stackable Storage Solutions Our Space-Saving Multi-Fluid Storage and Handling Solutions are Backed by Decades
More informationLongest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!
DB 750-205 January 2007 Supercedes: December 2006 Now available with Vacuum Interrupter Monitor VBT Switch 15kV - 69kV VBU-T Switch 69kV - 230kV Longest Life Product for Electric Furnace Applications!
More informationPRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS
OWNER'S MANUAL SAVE THESE INSTRUCTIONS PRO20-115 PRO20-115RD 115-Volt AC PRO20-115AD Automatic Diesel Nozzle PRO20-115MD Manual Diesel Nozzle PRO20-115PO Pump Only PRO20-115RD For Remote Dispensing Systems
More informationSINGLE ACTION FLUID PUMP
SINGLE ACTION FLUID PUMP MODELS 4490, 4491, 4492 S SERIES A Model 4492 (Stub Pump) Model 4491 (250-275 Gal) Model 4490 (16-55 Gal) Model A52347R-248 (250-275 Gal NOV - 2006 Section -A6 Page -63A Table
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 500REOZVB 550/600REOZV Weather Enclosure Sound Enclosure Weather Enclosure Features
More informationSee page 167 for sizing charts
Pipe Snap N Shield Clevis Size Range: 2.34" (59.4mm), 3.45" (87.6mm), 4.50" (114.3mm), 5.53" (140.4mm), 6.64" (168.5mm), and 8.64" (219.4mm) Shield Openings Material: Plastic - Gray Thermylene P6-20FG-0738
More information12 French Drive Mono, ON Canada L9W 5W1 Ph Toll Free Fax
CONTROL HANDLES AND ELECTRONIC METERS 12 French Drive Mono, ON Canada L9W 5W1 Ph. 519-942-8800 Toll Free 1-800-252-5636 Fax 519-942-4799 info@appliedlubrication.com oil Electronic meter RAASM s electronic
More information2010 MaxxForce 11 & 13 Fuel System Priming Tool Training for Technicians Study Guide
TMT - 121307 Class Course Code: SD8361 January 2013 2010 MaxxForce 11 & 13 Fuel System Priming Tool Training for Technicians Study Guide 2010 MaxxForce 11 & 13 Fuel System Priming Tool Study Guide 2013
More informationPumping Industry 101. THE DYNAMICS of pumping grease waste works and the responsibilities we carry
Pumping Industry 101 THE DYNAMICS of pumping grease waste works and the responsibilities we carry PUMP TRUCK PUMPING OF GREASE WASTE WORKS Different brands Different sizes Vacuum Pumps Different vacuum
More informationFJORD AVIATION PRODUCTS
MODEL NUMBER DESCRIPTION Page 01 CROSS REFERENCE Replacement Part Numbers Page 02 AFP-1824 & AFP-1836 Wing Mat for Aircraft Fueling & Engine Access Page 03 SFN Spout Covers For OPW 295 Series Aviation
More informationBulk Supply Station. Collins Ink
Collins Ink Bulk Supply Station Collins Ink s Bulk Supply Station provides a simple alternative to cartridges for high volume applications, while cutting ink costs up 50%. Each gravity fed system consists
More informationIndustrial Pumping Equipment PileDriver III Series III Air Motor Features
PileDriver III Series III Air Motor Features These fully pneumatic air motors reverse stroke direction without mechanical linkages and are simpler and more reliable than older designs. Air motors are 3,
More informationMODEL E & PE REGULATORS
The model E & PE are engine heated two-stage regulator/vaporizers. The model E provides a choice of two negative outlet pressures. A blue secondary spring to provide a -1.5 w.c. (0.37 kpa) output and an
More informationFUELING SYSTEM. With the fueling hose connected to the fueling manifold and the three fueling valves open, fuel is supplied to the three tanks.
FUELING SYSTEM System The fueling station provides means to fill and service the fuel tanks to any specified level. In addition, the fuel tanks can be defueled or fuel can be transferred from tank to tank
More informationVersa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar
Versa-Matic Operating Manual 3/8" Bolted Plastic Pumps Polypropylene Kynar E8 SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser
More informationAPPLICATION for BUSINESS LICENSE Licensing & Permits City of Williston PO Box 1306, Williston, ND
APPLICATION for BUSINESS LICENSE Licensing & Permits City of Williston PO Box 1306, Williston, ND 58801 cityauditor@ci.williston.nd.us BULK STORAGE & HANDLING OF FLAMMABLE LIQUIDS & HAZARDOUS MATERIALS
More informationESS.DG.HT611 Life Safety Earthsafe Systems, Inc. Page 1
ESS.HT.611.How to Design a Life Safety Fuel System How to Design a Life Safety Generator Fuel System earth safe Fuel Systems for Critical Power Life Safety Generator Fuel Systems can be complex. They need
More informationFrequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania
Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania NISTM 6 th Annual Pennsylvania Storage Tank Conference April 9, 2015 Presented by: Randy Martin Solid Waste Program
More informationPortable Sealcoating Spray Systems
Portable Sealcoating Spray Systems Operator s Manual RA-SSY-0005 RA-SSY-0004 RA-SSY-0013 RA-SSY-0011 RA-SSY-0003 RA-SSY-0012 * RA-SSY-0005 Pictured Above 1 SAFETY WARNING Read all instructions and warnings
More informationENVIRONMENTAL FIELD PROCEDURE EFP 06 FUEL HANDLING
Purpose and Scope This Environmental Field Procedure (EFP) applies to all BCTS clients (Licensee, Permittee and Contractor workers) and BCTS staff who are responsible for fuel handling within the scope
More informationQ= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications
1 of 9 1. DESCRIPTION The Viking Flow Control Valve is a quick opening, differential diaphragm flood valve with a spring loaded floating clapper. The Flow Control Valve can be used to facilitate manual
More informationIndustrial Pumping Equipment Air-Operated Diaphragm Pumps
Industrial ing Equipment -Operated Diaphragm s 85630 85628 85622 85634 ¼" - 2" -Operated s Basic Design Features Diaphragm pumps are driven by compressed air.the directional air distribution valve and
More informationFIXED SPEED SUBMERGED TURBINE PUMPS STP
FIXED SPEED SUBMERGED TURBINE PUMPS STP MagShell SETS A NEW STANDARD FOR SUBMERSIBLE PUMP PERFORMANCE SUBMERGED TURBINE PUMPS Since the mid 190 s, FE Petro s parent company, Franklin Electric, has been