215 Gallon Waste Oil Tank With Metering Pump Installation Instructions

Size: px
Start display at page:

Download "215 Gallon Waste Oil Tank With Metering Pump Installation Instructions"

Transcription

1 215 Gallon Waste Oil Tank With Metering Pump Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin

2 BEFORE YOU BEGIN INSTALLATION... IMPORTANT Read and understand this manual completely before beginning installation. This tank is for commercial and industrial use only. This unit is not intended for residential use. Install Heater/Tank combination in an area that is protected from fork lift and motor vehicle traffic. Bolt tank to floor before you fill the tank or install the heater. Secure the heater to a permanent structure after installation. Install the heater according to the printed information in your owners manual. Installation of this unit must be made in accordance with state and local codes or authorities having jurisdiction over environmental control, fuel, fire and electrical safety. Read and familiarize yourself with these instructions and associated photos, diagrams and illustrations before beginning installation or operation. These instructions should be followed closely, to achieve the best possible results. If you have questions or concerns at any time during the installation, stop the installation and contact a Lanair Service Representative. Check to make sure you have all the required components needed for proper installation and operation. Check each component for visible damage. If you find a damaged component, contact a Lanair Service Representative for a replacement. Do not install broken or damaged parts. Read and understand the warranty. Fill out the enclosed warranty card and return within 10 days of purchase. Clean and de-burr all pipe connections prior to use. Loose filings and burrs can clog the nozzle.! Install Heater/Tank combination in an area that is protected from fork lift and motor vehicle traffic. Bolt tank to floor before you fill the tank or install the heater. Secure the heater to a permanent structure after installation. Install the heater according to the printed information in your owners manual. 2 QUESTIONS?... Contact Customer Service at M-F 8:00 am- 4:30 pm CST

3 Section 1 - Plumbing Kit Parts List Part # 8917 Brass Elbow 3/8 Comp x 1/4 NPT Part # 8902 Elbow Street Part # 8602 Elbow Part # 9412 Tee x 1/4 x Part # 8186 Nipple Close QTY: 5 Part # 8647 Nipple Close 1/4 Part # 8558 Coupling Reducing x 1/4 Part # 7101 Screw #10 x 1 QTY: 4 Part # 8185 Pipe Plug Part # 8904 Bushing x 1 Part # 8556 Union Part # 8919 Tee x x Part # 8557 Nipple x 5- Part # 8924 Cap METERING PUMP TEE ASSEMBLY (P/N 9981) PARTS LIST Part # 8909 Tee 1/4 x 1/4 x 1/4 Part # 8915 Nipple 1/8 x 2 Part # 8917 Brass Elbow 3/8 Comp x 1/4 NPT Part # 8939 Brass Fitting 3/8 Comp x 1/4 NPT Part # 8462 Check Valve 1/4 NPT x 1/4 FNPT Part # 8908 Bushing 1/8 x 1/4 NOTICE! METERING PUMP TEE ASSEMBLY IS PRE-ASSEMBLED WITH METERING PUMP Visit our website at: 3

4 Section 1 - Plumbing Kit Parts List Part # 7043 Screw 5/16-18 x 1 Qty: 4 Part # 7427 Washer Lock 5/16 Qty: 4 Part # 7417 Washer Flat 5/16 Qty: 4 Part # 7207 Nut 5/16-18 Qty: 4 Part # 8187 Ball Valve Qty: 1 Part # 5277 Thread Sealing Compound Qty: 1 Part # 9030 Pick-up Tube Qty: 1 Part # /8 Copper Tube 180 Qty: 1 4 QUESTIONS?... Contact Customer Service at M-F 8:00 am- 4:30 pm CST

5 Section 2 - Installation Instructions TANK INSTALLATION FIGURE 1 1. Unwrap the tank and parts. 2. Choose tank location. Locate the tank in an area that is protected from lift truck and motor vehicle traffic. NOTE: Make sure you have enough room to install and service your heater. 3. Anchor all four legs of the tank to the floor as indicated In Fig. 1. NOTE: This method of anchoring is a suggestion only. Anchoring methods may vary per individual applications and environments. Check state and local codes for clarification. 4. Install the four tank legs included with the tank on top of the bottom legs (see Fig. 2). 5. Using a forklift, lift and center the heater on top of the platform. NOTE: The front of each unit is indicated on the top of the tank platform 6. Using a forklift, carefully raise the platform and heater assembly and place on top of the previously installed legs (see Fig. 2). 7. Locate the four holes on the bottom side of the heater platform. Attach the heater to the platform using four #10 x 1" screws provided. Heater Assembly Top Tank Leg Platform Concrete Anchor (not included) Burner on Right Bottom Tank Leg Pump Platform Label FIGURE 2 Visit our website at: 5

6 Section 3 - Plumbing Installation FIGURE 3- Top View of Tank * Included in the Heater Accessory Kit VENT EMERGENCY VENT PICK-UP TUBE P/N 9030 Pick-Up Tube Part # 9030 Pick-up Tube PRIMARY STRAINER PUMP HEAD METERING PUMP ASSEMBLY Tank Top Tank Top 2" Bushing 2 Bushing FILL BUNG PLUMBING INSTALLATION - Pick-Up Tube Assembly 1. Unpack and lay out all of the parts shipped with your tank and heater. Before beginning assembly, make sure all lines and fittings are free of dirt and/or burrs. NOTE: When making plumbing connections, use the thread seal compound (P/N 5277) included in the plumbing kit on all joints. DO NOT USE TEFLON TAPE. P/N 8748 Suction Line Strainer FIGURE 4 Part # 8748* Suction Line Strainer P/N 8662 Check Valve (arrow Part # 8662* Check Valve pointing up) (Arrow pointing up) P/N Part # 8902 Elbow Street Elbow Street 1/2" 2. Locate the pick-up tube assembly (P/N 9030). This tube will have a 2" bushing welded onto it. 3. Attach the brass check valve (P/N included in the heater accessory kit) to the bottom of the pick-up tube assembly (P/N 9030). NOTE: The arrow on the check valve must point in the direction of the oil flow (up) or the check valve will not work properly (see Fig. 4). 4. Attach the 1/2" elbow (P/N 8902) to the check valve. Attach the suction line strainer (P/N included in the heater accessory kit) to the 1/2" elbow (P/N 8902) as indicated in Fig Insert the pick-up tube assembly into the 2" bung (hole) and tighten (see Fig. 3 for bung location). 6 QUESTIONS?... Contact Customer Service at M-F 8:00 am- 4:30 pm CST

7 Section 3 - Plumbing Installation PICK-UP TUBE ASSEMBLY P/N 8924 Cap P/N 8919 Tee 1/2" x x P/N 8186 Close Nipple 1/2" P/N 8904 Bushing 1/2" x 1" METERING PUMP TEE ASSEMBLY (Included & Pre-Assembled With Metering Pump) P/N 8904 Bushing 1/2" x 1" P/N 8902 Elbow Street 1/2" FIGURE 5 P/N 8186 Nipple Close 1/2" P/N 9412 Tee P/N 9807 Primary Strainer Arrows must point in direction of oil flow P/N 8556 Union P/N 8186 Nipple Close 1/2" Separate Here P/N 8557 Close Nipple 1/2" x 5-1/2" PUMP HEAD P/N 8647 Nipple Close 1/4" P/N 8558 Reducing Coupling 1/4" x 1/2" P/N 8902 Elbow Street 1/2" METERING PUMP ASSEMBLY 5/16" x 1" Bolt P/N /16" Loc Washer P/N /16" Washer P/N /16" Nut P/N 7207 (4 locations, Do Not Tighten until all plumbing connections are made PLUMBING INSTALLATION - Pick-Up Tube to Pump Plumbing Attach the pump assembly to the top of the tank bracket (see Figs. 2 and 3 for bracket location) using four 5/16" x 1" bolts, loc washers, washers and nuts (See Fig. 5). NOTE: Do not tighten until all plumbing connections are made. Install 1/2" tee (P/N 8919), 1/2" close nipple (P/N 8186) and 1/2" x 1" bushing (P/N 8904) to the top of the previously installed pick-up tube assembly. Install x 5- nipple (P/N 8557) and cap (P/N 8924) to top of tee. NOTE: When making plumbing connections, use the thread seal compound (P/N 5277) included in the plumbing kit on all joints. DO NOT USE TEFLON TAPE. Attach the primary strainer assembly (P/N included in heater accessory kit) to the previously installed components. NOTE: Make sure that the arrows on the top of the strainer are pointed in the direction of the oil flow (see Fig. 5). Install a 1/2" x 1" bushing (P/N 8904), 1/2" elbow street (P/N 8902), 1/2" close nipple (P/N 8186), 1/2" x 1/4" x 1/2" tee (P/N 9412), 1/2" close nipple (P/N 8186) and Union (P/N 8556) to the primary strainer assembly (P/N 9807) as indicated in Fig. 5 above. NOTE: When making plumbing connections, use the thread seal compound (P/N 5277) included in the plumbing kit on all joints. DO NOT USE TEFLON TAPE. Visit our website at: 7

8 Section 3 - Plumbing Installation PLUMBING INSTALLATION - Pick-Up Tube to Pump Plumbing (cont.) 5. Install a 1/4" close nipple (P/N 8647) to the pump head (see Fig. 5, page 7). 6. Install a 1/4" x 1/2" reducing coupling (P/N 8558), 1/2" street elbow (P/N 8902) and 1/2" x 5" nipple to the previously installed 1/4" close nipple (see Fig. 5, page 7). P/N 8398 Vacuum Gauge 7. Separate the 1/2" union (P/N 8556) as indicated in Fig Attach the separated part of the union to the 1/2" x 5" nipple. Re-assemble the union and tighten. 9. Check to make sure all joints are tight. NOTE: Failure to do so will result in suction leaks (drawing air into oil) causing the heater to operate improperly. Tighten the pump assembly to the bracket. Install the vacuum gauge (P/N included in the heater accessory kit) to the previously attached 1/2" x 1/4" x 1/2" tee (P/N 9412) as indicated in Fig. 6. PLUMBING INSTALLATION - Pump to Burner Assembly 1. Install the Metering Pump Tee Assembly into the pump head outlet as indicated in Fig. 7. FIGURE 6 2. Install the 3/8" copper tube (P/N 8921) between the compression fitting of the Metering Pump Tee Assembly and and the compression fitting on the burner assembly (see Fig 7) FIGURE 7 METERING PUMP TEE ASSEMBLY (Included & Pre-Assembled With Metering Pump) (P/N 9981) PUMP HEAD METERING PUMP ASSEMBLY 8 QUESTIONS?... Contact Customer Service at M-F 8:00 am- 4:30 pm CST

9 Section 3 - Plumbing Installation FIGURE 8 PLUMBING INSTALLATION - To Burner 1. Attach the 3/8" comp x 1/4" NPT brass elbow (P/N 8917) as indicated in Fig 8. P/N 8917 Brass Elbow 3/8" comp x 1/4 NPT 3/8" Copper Tube To tee assembly on pump 2. Install the remaining 3/8" copper tube between the compression fittings of the by-pass regulator and burner (see Fig 8). NOTE: Make sure all fittings are properly tightened. Leaking fittings may cause delayed ignition in the burner. 3. Assemble a close nipple (P/N 8186, x 1/4 reducing coupling (P/N 8558), and 3/8 comp x 1/4 MPT brass elbow (P/N 8917). Install this assembly into the bung on the top of the tank. Connect a 3/8 copper tube from the relief valve on the metering pump to the assembly described above (see Fig 3 & 8). Tank Drain and Plug 1. Determine which side of the tank the drain will be on. On that side, install a 1/2" close nipple (P/N 8186) to the drain hole (see Fig 9). 2. Install the 1/2" brass ball valve (P/N 8187) to the 1/2" close nipple. Install a 1/2" pipe plug (P/N 8185) into the end of the ball valve (see Fig 9). 3. Install a 1/2" pipe plug (P/N 8185) into the hole on the opposite side of the tank (see Fig 10). 4. Vent the tank in accordance to state and local codes. FIGURE 10 P/N 8185 P/N /2" Pipe Plug 1/2" Close Nipple P/N /2" Pipe Plug P/N /2" Brass Ball Valve FIGURE 9 9 QUESTIONS?... Contact Customer Service at M-F 8:00 am- 4:30 pm CST

10 Section 4 - Reference Diagram TANK LEG TANK LEG VACUUM GAUGE PUMP HEAD PUMP ASSEMBLY PRIMARY STRAINER PUMP MOUNTING BRACKET 215 GALLON TANK DRAIN VALVE SUCTION LINE STRAINER PIPE PLUG Visit our website at: 10

11 Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin Lanair Products LLC Lanair is a registered trademark of Lanair Products LLC Part # 5300 Rev. 16 REV

Instructions for Installation, Operation Care and Maintenance

Instructions for Installation, Operation Care and Maintenance Model A Dry Pipe Valve Bulletin 353 Rev.K Bulletin 353 Rev.K Instructions for Installation, Operation Care and Maintenance 2 1 2 (65mm) Valve With Model A Trim Listed by Underwriters Laboratories, Inc.

More information

CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL

CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS C24GA6 C24GA10 ML-136056 ML-136057 PRIOR MLS COVERED IN THIS MANUAL C24GA6 C24GA10 ML-136021 ML-136022 For additional information on

More information

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75" quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed

More information

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES 8 VALVE FITTING PART NUMBERS 2" & 3" PRESSURE REDUCING VALVES* 10645 8970-002 (9526-006) 1/4" tube (9526-006) Flow 8970-001 (9526-001) 8970-010 (9526-010)

More information

Installation & Operator s Manual

Installation & Operator s Manual Installation & Operator s Manual LS5 Liquid Spray System 2 x 105 Gallon Tanks Installation Instructions 1. Position pump enclosure bracket (#3028485) 4 from rear gusset on driver side of hopper spreader,

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 Gas Convection Steamers C24GA6 ML-136056 C24GA10 ML-136057 C24GA6 ML-136021 C24GA10 ML-136022 VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC 3600 NORTH

More information

M O D E L S EST- FL PARTS MANUAL Rev 1.00A

M O D E L S EST- FL PARTS MANUAL Rev 1.00A M O D E L S EST- FL PARTS MANUAL Rev 1.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com TABLE

More information

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75 quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed

More information

27" Natural Gas Conversion Manual

27 Natural Gas Conversion Manual S o n o m a PLATINUM EDITION 27" Natural Gas Conversion Manual FOR OUTDOOR USE ONLY TM 1 2 3 4 8 7 5 9 6 Part No. Qty Description 1 44213827 1 Hose 27" - 3/8" Flare Both Ends for Side Burner (NG) 2 40275101

More information

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 54-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Model D Dry Pipe Valve Bulletin 350 Rev. S Bulletin 350 Rev. S Instructions for Installation, Operation, Care and Maintenance 4 (100mm) 6 (150mm) Valve With Model D Trimmings Listed by Underwriters Laboratories,

More information

Installation / Operation Manual

Installation / Operation Manual Installation / Operation Manual Installation Requirements Pressure Range: 10-150 psi Temperature Range: 40-120 F Max Service Flow Rate: 25gpm NOTE: Position filter on a level surface. Filter must be installed

More information

P239-1 Supply Pumper Instructions

P239-1 Supply Pumper Instructions P239-1 Supply Pumper Instructions STOP! READ THIS SECTION NOW. The following information is critical to the proper installation and operation of this Oil Supply System! Read it carefully before starting

More information

SERVICE MANUAL / PARTS LIST MODEL XSG-5

SERVICE MANUAL / PARTS LIST MODEL XSG-5 ation SERVICE MANUAL / PARTS LIST MODEL XSG-5 1055 Mendell Davis Drive Jackson MS 39272 888-994-7636 601-372-3903 Fax 888-864-7636 unifiedbrands.net PART NUMBER 158634 REV B (11/11) TABLE OF CONTENTS 2

More information

Model 8309WC Barrier Free Shower & Eye/Face Wash

Model 8309WC Barrier Free Shower & Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com No. 2067461(15) Model 8309WC

More information

Parts List. Item # Part # # Reqd. Description

Parts List. Item # Part # # Reqd. Description 5.2017.6.f 1 3800 Series Injector 1 2 3 4 5 6 7 21 8 9 20 10 11 12 19 18 17 16 15 14 13 Parts List Item # Part # # Reqd. Description 1 A-0664 1 5 Gallon 430 Reservoir 2 A-0575 1 Thumb Screw 3 A-0172 1

More information

Doorway Foamer. Packers Chemical 3729 Peddle Hollow Rd Kieler Wi, Phone Fax

Doorway Foamer. Packers Chemical 3729 Peddle Hollow Rd Kieler Wi, Phone Fax Doorway Foamer Packers Chemical 3729 Peddle Hollow Rd Kieler Wi, 53812 Phone 608.568.3841 Fax 608.568.7582 Doorway Foamer SAFETY As with any equipment of this type, when electricity and chemicals are involved,

More information

Polypropylene Piston Drum Pumps

Polypropylene Piston Drum Pumps Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS TITAN pt. no.: 99 0000 0509 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS I n B e d F u e l T a n k Shown

More information

Model 8309WC Barrier Free Shower & Eye/Face Wash

Model 8309WC Barrier Free Shower & Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8309WC Barrier Free Shower

More information

Installation & Operator s Manual

Installation & Operator s Manual Installation & Operator s Manual LS6 Liquid Spray System for SHPE1500, 2000 Style Spreaders Installation Instructions 1. Position Support (3013939) in truck s bed. Place 30 gal. Tank (#3014062) on support

More information

DIGIFLO ELECTRONIC FLOWMETER

DIGIFLO ELECTRONIC FLOWMETER DIGIFLO ELECTRONIC FLOWMETER PIPE FITTING INSTALLATION MANUAL SADDLE MACHINED IN-LINE BODY MOLDED IN-LINE BODY MOLDED TEE Blue-White R Industries, Ltd. F-2000 Page 2 1.0 Temperature vs. Pressure Temperature

More information

Double Diaphragm with Pressure-Type Leak Detector. For MILROYAL, CENTRAC B And MAXROY

Double Diaphragm with Pressure-Type Leak Detector. For MILROYAL, CENTRAC B And MAXROY Double Diaphragm with Pressure-Type Leak Detector For MILROYAL, CENTRAC B And MAXROY Manual No : 54126 Rev. : 00 Rev. Date : 02/2016 PRECAUTIONS The following precautions should be taken when working with

More information

MODEL L-1X & L-1X16 PARTS MANUAL

MODEL L-1X & L-1X16 PARTS MANUAL MODEL L-1X & L-1X16 PARTS MANUAL Rev 1.17A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 TABLE OF CONTENTS MODEL CMA-L-1X & L-1X16 1. PARTS MANUAL...3

More information

Installation & Operator s Manual

Installation & Operator s Manual Installation & Operator s Manual LS7 Liquid Spray System for SCH Style Spreaders Installation Instructions 1. Position and weld Enclosure Bracket (#3028485) and Support (#3014077) to spreader as shown

More information

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 www.cmadishmachines.com TABLE OF CONTENTS PARTS

More information

55-Gallon Powder Drum Truck

55-Gallon Powder Drum Truck Instruction Sheet P/N 0 0 -Gallon Powder Drum Truck for Bulk-Feed Powder Transfer Systems Description See Figure. The -gallon powder drum truck automatically adds bulk powder to a powder coating system

More information

TL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97

TL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97 Fuel Section Fuel Page 9-1 Fuel Tank Between The Rails Page 9-2 Fuel Fuel Tank Between The Rail Item Part Num. Number Qty. Description Notes 1 61360662 1 Elbow, 90 o, 1/2" NPT x 5/8" T 2 61270100 1 Sender

More information

PARTS LIST PRESSURELESS COOKER MODELS: GSX-5HE, GSX-7HE, GSX-10HE

PARTS LIST PRESSURELESS COOKER MODELS: GSX-5HE, GSX-7HE, GSX-10HE PARTS LIST PRESSURELESS COOKER MODELS: 5HE, 7HE, 10HE CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324 PRINTED IN

More information

DESCRIPTION MECHANICAL FUEL PUMP FUEL FILTER HIGH PRESSURE (35-90 PSI) HIGH PRESSURE (35-90 PSI) (STEEL/INCLUDED)

DESCRIPTION MECHANICAL FUEL PUMP FUEL FILTER HIGH PRESSURE (35-90 PSI) HIGH PRESSURE (35-90 PSI) (STEEL/INCLUDED) Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, 36032, 36033, 36034 INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. This installation

More information

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve To complement our extensive line of cable pressurization products, System Studies also sells a variety of air pipe and pressure tube fittings. This section of the catalog describes these commonly used

More information

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04B

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04B MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

MODEL L-1X & L-1X16 PARTS MANUAL

MODEL L-1X & L-1X16 PARTS MANUAL MODEL L-1X & L-1X16 PARTS MANUAL Rev 1.14 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 TABLE OF CONTENTS MODEL CMA-L-1X & L-1X16 1. PARTS MANUAL...3

More information

MODEL GLC PARTS MANUAL REV.1.02A

MODEL GLC PARTS MANUAL REV.1.02A Owner s Manual Keep with machine for reference MODEL GLC PARTS MANUAL REV.1.02A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 MODEL GL-C Parts MANUAL

More information

Model 8300 & 8300CRP Shower/Eyewash

Model 8300 & 8300CRP Shower/Eyewash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 HAWS AG Bachweg 3 CH-3401 Burgdorf Switzerland Haws Mfg. Pte Lt. 2A Sungei Kadet

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 407 Rev. T Model E Alarm Check Valve Bulletin 407 Rev. T Instructions for Installation, Operation, Care and Maintenance 4 (100 mm), 6 (150 mm), 8 (200 mm) Sizes With Model E3 Trim Listed by Underwriters

More information

Priming Systems Installation Instructions

Priming Systems Installation Instructions Priming Systems Installation Instructions System Components: Single Priming Pump: Single VAP Valve Systems: Control Panel Activated... 2 Auto Prime (Pressure Switch) Activated... 3 Multiple VAP Valve Systems...

More information

LEAK TEST PROCEDURE DC CHANNEL LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

LEAK TEST PROCEDURE DC CHANNEL LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE LEAK TEST PROCEDURE DC CHANNEL LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE TST-008 Rev. 2013-048 Page 1 of 10 THIS PAGE INTENTIONALLY

More information

Calcium Chloride Pump

Calcium Chloride Pump Parts List For Calcium Chloride Pump Model 10509 Calcium Chloride Pump ITEM PART NO. ITEM PART NO. NO. NO. REQ D DESCRIPTION NO. NO. REQ D DESCRIPTION 1 10537 2 Calcium Hose 10 x ¾ x 1 13 10565 1 Nipple,

More information

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6 TABLE OF CONTENTS TITLE PAGE Athletic Field Painting Pointers 1 44-508 Line Star Drawing 2 44-508 Line Star Parts List 3-4 Spray Boom Drawing 5 40-127 Stainless Steel Tank 6 4085 Spray Gun 7 40-153 Gun

More information

MODEL CMA-181GW PARTS MANUAL Rev 1.00B

MODEL CMA-181GW PARTS MANUAL Rev 1.00B MODEL CMA-181GW PARTS MANUAL Rev 1.00B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL SDKIT-730 & SDKIT-734 100% Bolt-On 150 PSI Train Horn System for 2011-2015 F-250 & F-350 Super Duty P/N SDKIT-730 P/N SDKIT-734 Thank you for purchasing a Kleinn Air Horns

More information

Extended Capacity Replacement Tanks for RAM Cummins Diesel Trucks

Extended Capacity Replacement Tanks for RAM Cummins Diesel Trucks TITAN pt. no.: 03 0000 0135 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended

More information

Tools Needed for Mounting Cleá Filling Station

Tools Needed for Mounting Cleá Filling Station ALWAYS OBSERVE PRODUCT SAFETY AND HANDLING INSTRUCTIONS. ALWAYS DIRECT DISCHARGE AWAY FROM YOU or other persons. ALWAYS DISPENSE CLEANERS AND CHEMICALS AS DIRECTED ON THE LABEL. ALWAYS DISPENSE INTO APPROVED

More information

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer SCS 2 BLACK SHADOW SERIES 3.1 DISPENSER ALWAYS OBSERVE PRODUCT SAFETY AND HANDLING INSTRUCTIONS. ALWAYS DIRECT DISCHARGE AWAY FROM YOU or other persons. ALWAYS DISPENSE CLEANERS AND CHEMICALS AS DIRECTED

More information

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC ML-136043 208/240 V. 8.5kW ML-136045 480 V. 8.5kW 3-PAN PRO ML-136037 208/240 V. 9.25kW ML-136044 480 V. 9.25kW ML-152030 3-PAN LWE 5-PAN BASIC

More information

Bid # Plumbing Supplies RESULTS

Bid # Plumbing Supplies RESULTS BOARD APPROVED Bid # 15-4 - Plumbing Supplies Page 1 of 16 Grant Plumbing North Brunswick NJ PVC PIPE, SCHEDULE 40 1 1-1/4" PVC Pipe, SCH 40, 20' feet 60 $0.598 $35.88 2 1-1/2" PVC Pipe, SCH 40, 20' feet

More information

MODEL EVA PARTS MANUAL Rev.1.05

MODEL EVA PARTS MANUAL Rev.1.05 MODEL EVA PARTS MANUAL Rev.1.05 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com TABLE OF CONTENTS MODEL EVA 1. PARTS MANUAL...3

More information

SECTION 6: PARTS SECTION

SECTION 6: PARTS SECTION PREWASH & WASH PUMP WELDMENTS Intake Suction Scoop Weldment 05700-021-87-60 Prewash Intake Strainer Weldment 05700-021-74-96 Wash Pump Weldment 05700-041-68-88 Prewash Strainer Bracket 05700-021-74-94

More information

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately) Installation Instructions and Parts Manual CPJ SERIES JET PUMPS Shallow Well Jet Pumps /3 - / HP CPJS SHALLOW WELL IL089 3/4 - -/ HP CPJS SHALLOW WELL Convertible Jet Pumps IL090 / HP CPJ CONVERTIBLE IL09

More information

Technical Bulletin. Parts and Service News

Technical Bulletin. Parts and Service News Equipment Affected: Part Number Affected: 02026-0430 Technical Bulletin Tractors with Hydro-Vac Brakes Part Description, HYDRO-VAC (VACUUM BOOSTER). Discrepancy, The vacuum booster may not provide enough

More information

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description Worldwide Contacts www.tyco-fire.com DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/ Inch to Inch (DN40 to DN00) General Description The TYCO DV-5a Automatic

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR COLD PLANER sprinkler KIT (LAF5400) INSTRUCTIONS NUMBER: MR05678 Complete operator s and parts manuals are supplied with the Cold Planer. 800-456-7100 www.paladinlcg.com 2800

More information

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011 EFFECTIVE: MAY, 2011 ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 213-0066 L-R / 214-0066 R-L ADC-66 Conveyor Dishwasher 2

More information

PolAIR High Pressure Fog Cooling System. Important Installation Notes Please read before starting installation

PolAIR High Pressure Fog Cooling System. Important Installation Notes Please read before starting installation PolAIR High Pressure Fog Cooling System Important Installation Notes Please read before starting installation Read operational manual for POlAIR Controller before starting. Familiarize yourself with the

More information

MICRO RAIN 50,58,&63 SPARE PARTS MANUAL JANUARY 1, 2005

MICRO RAIN 50,58,&63 SPARE PARTS MANUAL JANUARY 1, 2005 MICRO RAIN 50,58,&63 SPARE PARTS MANUAL JANUARY 1, 2005 Sheilding, Wheel Assys, Front Hitch Assy. Shielding,Wheel Assys, Front Hitch Assy. Ref. Part # Description Qty. 1 MR-88052112/8 Outer Chain Cover

More information

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been

More information

Model 8346/8346CRP Shower & Eye/Face Wash

Model 8346/8346CRP Shower & Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com No. 2080177(15) Model 8346/8346CRP

More information

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC Installation Manual Automated Fuel Maintenance System FTI-10A & FTI-20A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 03/01/2011 -

More information

MODEL GL-X PARTS MANUAL

MODEL GL-X PARTS MANUAL MODEL GL-X PARTS MANUAL Rev. 1.03A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 www.cmadishmachines.com TABLE OF CONTENTS MODEL CMA-GL-X 1. PARTS MANUAL...3

More information

INSTALLATION, OPERATING AND SERVICE MANUAL

INSTALLATION, OPERATING AND SERVICE MANUAL INSTALLATION, OPERATING AND SERVICE MANUAL ECONO-mist WATER SOFTENER Demand Regeneration 7-LMC56-75B 7-LM56-75B 7-LM56-100B 7-LM56-150B 7-LM56-200B Congratulations on purchasing your new Lancaster Water

More information

Jacobsen 600, Ransomes 700 Series

Jacobsen 600, Ransomes 700 Series Jacobsen 600, Ransomes 700 Series Soft Side/ROPS Parts List & Mounting Instructions Jodale Perry Printed: 2001/11 Standard Parts List Qty Description Photo L&R Rear Mounting Brackets L&R Front Mounting

More information

INSTALLATION TROUBLESHOOTING SUPPLEMENT

INSTALLATION TROUBLESHOOTING SUPPLEMENT TITAN Fuel Tanks INSTALLATION TROUBLESHOOTING SUPPLEMENT For Midship Replacement Fuel Tanks AND Utility Tanks This supplement is intended to provide additional information for installers to aid in simple

More information

LAWN SPRINKLER, IRRIGATION PUMP

LAWN SPRINKLER, IRRIGATION PUMP LAWN SPRINKLER, IRRIGATION PUMP MODEL #, SP0P, SP5P, SP20P, EL0P, EL5P, EL20P SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

More information

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) MP GS/GD Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com Page 2 Moisture + MP-GS/GD DESCRIPTION PAGE Deluxe Control Panel 4 Standard

More information

I-799/79V Coil Components

I-799/79V Coil Components WARNING Read and understand all instructions before attempting to install any Victaulic products. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 23 22 13 STEAM AND CONDENSATE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Installation S19-310LL. Combination Drench Shower and Eyewash

Installation S19-310LL. Combination Drench Shower and Eyewash Combination Drench Shower and Eyewash Table of Contents Pre-Installation Information... Supplies Required... Secure base to floor... Assemble components... Connect water supply... Assembly of Components...4

More information

Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, INSTALLATION INSTRUCTIONS

Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, INSTALLATION INSTRUCTIONS Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, 36032 INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. This installation can be

More information

INSTALLATION MANUAL APPLICATION: T 125G 45psi) CLASS 1-CLASS 8 *Requires a Fuel Line Kit*

INSTALLATION MANUAL APPLICATION: T 125G 45psi) CLASS 1-CLASS 8 *Requires a Fuel Line Kit* INSTALLATION MANUAL APPLICATION: T 125G (125GPH @ 45psi) CLASS 1-CLASS 8 *Requires a Fuel Line Kit* WARNINGs! WARNING: Do not tie FASS Return in with engine return. Back pressure can cause damage to engine.

More information

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.07B C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.07B C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.07B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

Model 8317 Combination Shower Eye/Face Wash

Model 8317 Combination Shower Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8317 Combination Shower

More information

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4 Page 1 of 5 Model F Dry Valve with Trim Valve Size Part Number 3 13764PTR 4 13765PTR 6 13766PTR Standard Trim Sets include galvanized nipples and fittings. 4 Dry Valve Shown General Notes: Notes: For use

More information

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE Technical Data SD 4011 SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE A SERIES AIR ADJUSTED PILOT PRINTED IN U.S.A. SD 4011/9504 Type A or A83 (wt 6 lb) Type A53 or A 85

More information

MODEL CMA-44 PARTS MANUAL Rev 2.13

MODEL CMA-44 PARTS MANUAL Rev 2.13 MODEL CMA-44 PARTS MANUAL Rev 2.13 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com Table of Contents CMA-44 1. PARTS MANUAL... 4

More information

PROMAX INSTRUCTION MANUAL

PROMAX INSTRUCTION MANUAL PROMAX INSTRUCTION MANUAL One Hand Activation Single Product [1 gpm (4l/m) models only] One Hand Activation 4 Product [1 gpm (4l/m) models only] Button Activation Single Product [1, 4, 8 gpm (4, 16, 30

More information

Installation. E19-310AC Combination Drench Shower and Eye/Face Wash. Table of Contents

Installation. E19-310AC Combination Drench Shower and Eye/Face Wash. Table of Contents Combination Drench Shower and Eye/Face Wash Table of Contents Pre- Information... Instructions... 3 Assembly of Components... 4 Parts List... 1-163ACE Rev. U; ECN 13-0-006 013 Bradley Page 1 of 1/1/013

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.

More information

OPERATOR'S MANUAL FOR DOUBLE ACTING PISTON HAND PUMP

OPERATOR'S MANUAL FOR DOUBLE ACTING PISTON HAND PUMP OPERATOR'S MANUAL FOR DOUBLE ACTING PISTON HAND PUMP OPERATION AND SERVICE GUIDE JAN. 00 Refer to Bulletin P-0 and Parts List P-9990. SAFETY PRECAUTIONS. This manual contains important information for

More information

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT 36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT DP 36-1 Assembly Instructions PLEASE READ INSTRUCTIONS COMPLETELY BEFORE STARTING We thank you for purchasing the DP-36 pressure system. This system has

More information

HVAC Products 2016 EDITION NCI CANADA INC.

HVAC Products 2016 EDITION NCI CANADA INC. HVAC Products 2016 EDITION NCI CANADA INC. YOUR SINGLE SOURCE SOLUTION NCI Canada Inc. is a Canadian National master distributor of high quality valves, fittings, pipes and related products serving residential,

More information

Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide

Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine

More information

Installation S19-310F. Combination Drench Shower and Eyewash

Installation S19-310F. Combination Drench Shower and Eyewash Combination Drench Shower and Eyewash Table of Contents Pre- Information... Instructions.... Assembly of Components... 4 Parts List... 5 15-16F Rev. T; ECN 1-05-016D 01 Bradley Page 1 of 5 6/4/1 P.O. Box

More information

C WD 2 WHEEL LOW KIT FOR DODGE RAM 4WD VEHICLES

C WD 2 WHEEL LOW KIT FOR DODGE RAM 4WD VEHICLES C18056-4WD 2 WHEEL LOW KIT FOR 1994-2002 DODGE RAM 4WD VEHICLES Pacbrake s 4WD 2 Wheel Low Kit allows the vehicle operator to engage the transfer case into 4WD low range without engaging the front wheel

More information

DISCONTINUED. Installation S19-310FSS. Stainless Steel Combination Drench Shower and Eyewash

DISCONTINUED. Installation S19-310FSS. Stainless Steel Combination Drench Shower and Eyewash Stainless Steel Combination Drench Shower and Eyewash Table of Contents Pre- Information........... Instructions............... Assembly of Components............ 4 Parts List.........................

More information

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX: ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PEDESTAL EYE/FACEWASH Models S0310 / S0320 /

More information

THE AquaBlast & RocketRide FUNSLIDES

THE AquaBlast & RocketRide FUNSLIDES THE AquaBlast & RocketRide FUNSLIDES ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH AquaBlast TM & RocketRide TM FUNSLIDES TM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL

More information

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications) Flow Max Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General Installation Instructions...

More information

Installation S19-310NN. Frost-Proof Combination Drench Shower and Eyewash (18", 3', 4', 5' or 6' Bury Depth)

Installation S19-310NN. Frost-Proof Combination Drench Shower and Eyewash (18, 3', 4', 5' or 6' Bury Depth) Frost-Proof Combination Drench Shower and Eyewash (18", 3', 4', 5' or 6' Bury Depth) Table of Contents Pre- Information...................... 2................................... 3 Assembly of Components.....................

More information

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX: ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS COMBINATION STATIONS Models: S1310, S1320, S1330,

More information

OPN DESCRIPTION QTY B-160 See next page for drawing of B-160 Blower -46-

OPN DESCRIPTION QTY B-160 See next page for drawing of B-160 Blower -46- -45- Models B-1501 B-160 OPN DESCRIPTION QTY A 002016 3/8" Jam Nut 8 B 010008 Support Rod Bracket 2 C 002017 3/8" Hex Lock Nut 2 D 100475 Lid Support Rod 2 E 010009 Lid Lift Bushings 4 F 010005 Drive-In

More information

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: Diesel Trucks Year: Engine: L6-6.7L (td)

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: Diesel Trucks Year: Engine: L6-6.7L (td) advanced FLOW engineering Instruction Manual P/N: 42-12035 Make: RAM Model: Diesel Trucks Year: 2013-2016 Engine: L6-6.7L (td) Please read the entire instruction manual before proceeding. Ensure all components

More information

Ford Meter Box Test Bench Installation Instructions

Ford Meter Box Test Bench Installation Instructions DQS Inc. 12/12/18 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Ford Meter Box Test Bench Installation Instructions Table of Contents Installation Instructions for Standard, Akron

More information

MODEL L-1C PARTS MANUAL

MODEL L-1C PARTS MANUAL MODEL L-1C PARTS MANUAL Rev 1.00A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895- 2141 www.cmadishmachines.com TABLE OF CONTENTS MODEL CMA-L-1C 1. PARTS MANUAL...

More information

MODEL L-1C PARTS MANUAL. Rev 1.00A C M A D I S H M A C H I N E S K N O T T A V E N U E GARDEN GROVE, CALIFORNIA

MODEL L-1C PARTS MANUAL. Rev 1.00A C M A D I S H M A C H I N E S K N O T T A V E N U E GARDEN GROVE, CALIFORNIA MODEL L-1C PARTS MANUAL Rev 1.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com TABLE OF CONTENTS

More information

PARTS LIST RALLY 1200 SAVE THESE INSTRUCTIONS

PARTS LIST RALLY 1200 SAVE THESE INSTRUCTIONS PARTS LIST RALLY 1200 SAVE THESE INSTRUCTIONS OVERVIEW 120 VOLT OVERVIEW 120 VOLT ITEM PART NO. DESCRIPTION QTY 1 4099011 CORD WRAP, (SET FOR ONE CORD, FASTENERS NOT INCLUDED) 2 2 9120935 1/4 WASHER,.268

More information

Lycoming AIRCRAFT ENGINES. IO-540-AC1A5 Wide Series Flange Crankcase Model Engine PARTS CATALOG PC

Lycoming AIRCRAFT ENGINES. IO-540-AC1A5 Wide Series Flange Crankcase Model Engine PARTS CATALOG PC AIRCRAFT ENGINES IO-540-ACA5 Wide Series Flange Crankcase Model Engine PARTS CATALOG PC-5- November 008 Lycoming 5 Oliver Street Williamsport, PA 770 U.S.A. 570/33-8 IO-540-ACA5 PARTS CATALOG This illustrated

More information