1 FUEL DISPENSING SYSTEMS Component Details SE V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter in Cabinet 1 Automatic Nozzle, Swivel & Hose 40 GPM Particulate Filter - 30 Micron 2 - Emergency Vents - MNPT - 16 oz Pop-up Leak Gauge Swing-arm or Clock Level Gauge Overfill Prevention Valve Atmospheric Vent with Pipe Drop Tube - Pump Suction Pipe - 3 Lift Spill Bowl or Remote Fill Minimum tank diameter 64 Proudly made in America
2 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet This Heavy Duty, positive displacement pump delivers up to 18 GPM (114 LPM) and is designed with Fill Rite's exclusive anti siphon safety feature. The motor is explosion proof UL/cUL listed and has sealed bearings, a heavy duty switch and thermal overload protection. The system is UL/cUL listed as well. For flexible and convenient applications, combine above ground pumps with Series 902 cabinet meters. Features & Benefits 20 GPM (76 LPM) 1/3 HP motor UL/cUL listed pump and motor Heavy duty cast iron construction Diesel, gasoline,. kerosene, E15, biodiesel up to B20 2 year warranty 2 in. threaded base for tank mounting
3 4-Wheel Mechanical Meter in Cabinet Fill Rite's FR902C model meter cabinets are constructed from heavy duty 15 guage steel and are powder coated to stand up to the harshest environments. Hood removal is quick and simple; remove three screws and the reset knob and you have access. The cabinet is pulser ready and all external wiring connections are placed in easy access locations. Features & Benefits 6 40 gpm 1 inlet / 1 outlet 4 digit mechanical gallon meter UL / cul certification For use with remote pumps Can be used with submersible pumps Replaces model FR902RU
4 1" Automatic Nozzle, Swivel & Hose, Gas & Diesel Fill a 200 gallon tank in less than 7 minutes. That's real time saved...every time you fill the tank. Industry leading flow isn't the only reward you will reap. The patent pending UL listed Ultra Hi Flow nozzle takes fuel transfer to a new level. For transfer of gasoline, diesel, or kerosene to large fuel capacity farm, fleet, or construction equipment, there is simply no better choice. Fueling has never been easier...or quicker. Don't let your nozzle slow up your work when it is most Features & Benefits UL listed for gasoline, diesel and kerosene 1 in NPT F inlet, 1 1/8 in OD spout Three position latch for automatic flow at 30, 24 and 8 GPM Angled outlet to minimize hose wear 50 PSI working pressure Heavy duty hanging hook compatible with all Fill Rite products Automatic shut off Convenient one finger hold open clip to set flow rate Rated to 20 Fahrenheit operation Insulated hand grip to minimize hot and cold handling Minimal spray pattern to reduce foaming and false shut offs Large spout spring to hold nozzle in place Viton seals and o rings for smooth valve operation Patent pending Made in USA
5 1" Swivel & Hose Model: S100H1315 Multi Plane, Full 360 spherical rotation for easy movement of the nozzle. Features & Benefits Double O ring Seals at each Swivel Provide Long Life at Low Temps ( 40 F/C) Compatible with Unleaded Gasoline, Diesel & Ethanol Blends through E10 Dispense Diesel Fuel, Gasoline, Grease Kerosene and Petroleum Oils. The Fill Rite hose is a blend of Nitrile and PVC external materials provides rugged protection against cuts, abrasions, snags. Puncture Resistant. Features & Benefits Dispense diesel fuel, gasoline, kerosene, and petroleum oils Neoprene exterior Designed for use with all electric pumps High quality Nitrile inner tube
6 40 GPM Particulate Filter - 30 Micron & Filter Head Particulate Fuel Dispenser Filter is designed with resin impregnated cellulose media for the removal of dirt, rust and microbes. Features & Benefits 30 Micron Filter 50 psi 40 gpm 1 1/2 16 Compatible with gasoline, diesel, ethanol blends up to 15% and ultra low sulfur diesel
7 Emergency Vents - MNPT - 16 oz UL Listed Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire. Emergency vents must be used in conjunction with a normal vent. Correct application of this vent requires proper vent size and selection for the tank system in order to meet the specific venting capacity. Code Compliance: API 2000 International Fire Code National Fire Code of Canada NFPA 1, 30, 30A, 31, 37, 110 PEI RP200 & PEI RP800 Underwriters Laboratories Inc. - UL-142, UL-2085 & UL Underwriters Laboratories of Canada - CAN/ULC S601-07, CAN/ULC S & CAN/ULC S California Air Resource Board (CARB) Phase 1 Enhanced Vapor Recovery (EVR) AST Certified Products (VR-402-B) Fig. 244OM WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILL OPERATE PROPERLY. Emergency vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state, and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing temperatures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airfl ow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank.
8 Leak Gauge - Pop-Up for tanks 96" diameter and smaller Top mounted liquid leak gauge that can measure from 6" to 170" in depth. Gauges are custom made in house to fit your tank. This gauge is designed to monitor either the interstitial space of a double wall containment system, or it can mount into an external monitoring pipe. Calibration: Consists of 3 pieces. Outer plastic piece, inner plastic piece, and a piece of paper in between. Red Lock Nut: HDPE Plastic. This gauge is a simple visual tool. If the red indicator rises into the viewing window, it is indicating that there is a leak occurring in the double wall containment system. Bushing: Aluminum bushing, can be 2 or 1.5. Once installed, simply view the calibration to monitor the interstitial space. The indicator is not calibrated. It simply indicates leak or no leak. Internal Rods: Standard construction is aluminum rods. Additional Options Leak Union: Compression union Audible Alarm Accessory: This feature can turn the mechanical gauge into an audible Hi or Lo level alarm. Gauge Guard: A cover that protects the exposed plastic components on top of the gauge. Environmental Protection The Leak gauge is officially approved for use in double wall containment systems by several state environmental protection agencies. Float: HDPE Plastic
9 Leak Gauge - Electronic for 120" diameter tanks Engineering Bulletin
10 Level Gauge - Swing Arm for tanks 64" diameter and smaller Top mounted liquid level gauge that can measure from 6" to 170 in depth. This gauge is a simple volume reading tool. The top of the red indicator is an indication of approximate fuel level in the tank. Once installed, simply view the calibration to monitor tank level. Indicator is calibrated in eighths of a tank on one side, and quarters of a tank on the other. Calibration: Consists of 3 pieces. Outer plastic piece, inner plastic piece, and a piece of paper in between. Red Lock Nut: HDPE Plastic. Bushing: Aluminum bushing, can be 2 or 1.5. Gauges are custom made in house to fit your tank. Can also accommodate for double walls and pipe risers. HDPE Float: High Density Polyethylene Plastic. Additional Options Audible Alarm Accessory: This feature can turn the mechanical gauge into an audible Hi or Lo level alarm. LED At-A-Glance Accessory: This feature can give mechanical gauge remote reading capability. Gauge Guard: A cover that protects the exposed plastic components on top of the gauge. Internal Rods: Standard construction is galvanized steel rods with brass rivets. These replacement parts are available. Red HDPE Plastic Nut Duro Nitrile Gasket Plastic cellulose acetate inner and outer calibration Aluminum Lock Nut Glass inner calibration
11 Level Gauge - Clock-style for 72" and larger diameter tanks Features Gallon Ga Easy to install on a 2" female threaded tank opening Vapor tight up to 5 PSI Swivel base rotates 360 for optimum viewing angle Measures liquid levels up to 12' (3.6 meters) Proven anti-fog design High level indicated by red zone indicator Stainless steel fl oat and cable Drop tube float and drop tube available for tanks with higher-than-normal turbulence Compatible with ethanol blends up to 85% Compatible with biodiesel blends up to 100% Intrinsically safe alarm is battery powered Liter reading gauges available Includes field adjustable 90 decibel high level audible alarm Standard oat
12 Overfill Prevention Valve The overfill prevention valve is installed at the fill port of a storage tank. Used in a pressurized tight fill application, the valve helps prevent tank overfills by closing when the liquid level reaches a pre-set warning level (90-95% full). The valve is installed through a 4" or 6" threaded opening and has a built-in bleed hole that allows the fill hose pressure to be relieved after the valve closes. This bleed hole also provides anti-siphon protection for the valve. When installed to manufacturer requirements, the overfill prevention valve can eliminate hazardous liquid spills. The valve can be used in conjunction with AST spill containers or remote fill boxes for added spill protection. All models are supplied with an adaptor to mount an aluminum drop tube. A test mechanism is also sold separately if needed. The test mechanism allows a technician to pull on the test line at any time during the filling process to actuate the float and stop the filling process. This allows a technician to verify the valve is working properly. Features The 3" valve can be used with 6" Sch. 40 or 80 pipe. The 2" valves can only be used with 4" Sch. 40 pipe. Construction Details Anodized aluminum body Brass/stainless steel internal components Stainless steel linkage Failure to follow any or all of the warnings listed below may render the valve non-functional and could result in an accidental product spill, property damage, fire, explosion, injury or death. Warnings and Cautions 5 PSI & 5 GPM is the minimum flow requirement for valve operation. Valve will NOT function in gravity fill applications. Maximum viscosities (in centistokes): 2" Valve-150, 3" Valve-60. Flow rate of the 2" valve is 350 GPM maximum flow ( PSI pressure drop). The 3" valve is 800 GPM maximum flow rate ( PSI pressure drop). Once closed the valve will allow fl ow of less than 2% of max fl ow rate to relieve fill line pressure. A tight fill is required for the valve to operate. Do not substitute any other fill adaptors for the special adaptor supplied. The valve must be used with clean product. Debris from products such as contaminated used oil may cause the valve to function improperly. These valves are rated for a maximum pressure of 100 PSI. Not suitable for motor oil or other heavy oils. Consult Morrison Bros. Co. for product compatibility with the valve. Code Compliance ULC, NFPA 30, 30A, UFC, IFC and PEI /RP200, PEI /RP600, Florida DEP EQ356, CARB VR 402A
13 Drop Tube & Normal (Mushroom) Vent with Pipe The drop tube directs product flow to liquid level when filling a storage tank. The drop tube prevents free fill and reduces agitation of liquid when filling. The flanges fits between tight fill adaptor riser pipe. The tube extends to near bottom for submerged fill. All drop tubes are extruded aluminum. The 2 and 3 drop tubes can also be attached to the AST Overfill Prevention Valve. Drop tube length determined by tank diameter. Mushroom style free flow vent Stainless-steel mesh screen. Domed vent top prevents tank contamination from entering vent lines. NPT threads Cast iron, zinc plated 2" diameter galvanized steel vent pipe Length determined by tank volume/size
14 Remote Fill Port Spill capacity 10 gallons 14 gauge Stainless-steel construction Inlet and outlet available in 2" or 3" size Includes: Dust plug Quick disconnect - female Check valve Hand transfer pump Transfer hose with check valve and ball valve assembly Ball valve Outlet Mounting Brackets as needed 1" Drain fitting Hinged door wiht locking handle VR 4" aluminum adapter X 3" NPT VR 4" aluminum cam lever cap. 3" Stainless-steel full coupling 3" Stainless-steel nipple
FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System
FUEL DISPENSING SYSTEMS Component Details SE-27 12V DC - 15 GPM Metered Tank-top Dispensing System 12V DC Electric Pump - 1 Inlet - 3/4 Outlet 3-Wheel Mechanical Meter 1 Automatic Nozzle, Swivel & Hose
More informationFUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System
FUEL DISPENSING SYSTEMS Component Details SE-37 120V AC - 20 GPM Metered Tank-top Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter 1" Automatic Nozzle, Swivel
More informationFuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle
Pumps 110300-2 DC Aluminum Gear Fuel Pump with Auto Nozzle 110300-2 12-Volt DC - Rotary Gear. Explosion Proof Motor. Up to 18 GPM (69 LPM) 12 ft. (3.7m) x 1 in. Hose 137100-01 EZ-8 DC Fuel Pump 137100-01
More informationAboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.
Aboveground Tank Equipment Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co. HISTORY Morrison Bros. Co. Then Founded in 1855 Located in Dubuque, Iowa Originally a boiler manufacturer
More informationABOVEGROUND STORAGE TANK PRODUCTS CATALOG
NEW PRODUCTS! ABOVEGROUND STORAGE TANK PRODUCTS CATALOG NEW UL Listing! High Flow Emergency Vents Emergency Valves Overfill Prevention Valves Audible Alarms Spill Containment Box Overfill Prevention Valves
More informationER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent
CARB Phase I Enhanced Vapor Recovery AST Certified Products 5 (VR-402-B) Sensor Pressure Vacuum 0 Monitoring Clock Gauge Direct Fill Spill Container Dust Cap 9 2 Overfill Prevention Gauge Stick Port Suction
More informationER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent
CARB Phase I Enhanced Vapor Recovery AST Certified Products 5 (VR-402-D) Sensor Pressure Vacuum 10 Monitoring 1 12 or 34 Clock Gauge Direct Fill Spill Container 6 9 2 Overfill Gauge Stick Port Prevention
More informationRELIANCE G6200 MECHANICAL FLEET DISPENSER
RELIANCE G6200 MECHANICAL FLEET DISPENSER Wayne Reliance G6200 Series Mechanical Fleet Dispensers Fueling capabilities you can depend on down the road Keeping your fleet on the move depends on reliable,
More informationLUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading.
hand grease guns Lever type The tough high pressure cast iron head makes Pro-Master Grease Guns unique in comparison to common pot metal or other die cast heads with a head burst pressure of 17,000 PSI
More informationModel 1210C Battery Powered Pump Shown
Page 1 of 6 PRODUCT DATA SHEET 12 Volt DC Rotary Vane Pump Series 1200C Description of Included Models Available Options Safety Listings Accessories Performance Flow Curve Fluid Compatibility Dimensions
More informationNOW UL LISTED. Patented
NOW UL LISTED Patented Ø1.730 Ø 1.765 Ø.922 4.15 8.71 TOP VIEW 1.50 2" NPS THRDS. BOTTOM VIEW 2.13 2.14 SIDE VIEW 2.000 CLAY & BAILEY MFG. CO. 2" FILL SHUT OFF VALVE DATE:10/25/05 01228-03-2200 2" X 4"
More informationOverfill Prevention Valve
Overfill Prevention Valve The Guardian A1100 Materials Description Body: Aluminum Floats: HDPE Seals: Viton Specifications Weight: 4.3 lbs. Diameter: 3.76 Length: 18.0 Approvals CARB ULC City of New York
More informationModel FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.
Series 600 AC Powered Pumps Model FR610C Pump Shown of Included Models Model Number FR610C FR611C Heavy Duty AC Utility Pump with 3/4" X 12' Hose & Nozzle, Telescoping Suction Pipe and 1/4 HP - 115 VAC/60
More information1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions
1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions The 1618 Mechanical Gauge is designed to be used to measure liquid level in an aboveground storage tank. The gauge mounts to
More informationFuel Dispensing & Accessory Packages
Fuel Dispensing & Accessory Packages HT-1150 Highland Tank Highland Tank provides turnkey solutions to fuel dispensing. In addition to a quality tank from the industry leader, Highland Tank can provide
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that
More informationGeneral information about underground storage tank (UST) fueling systems in every day language.
What this document contains: General information about underground storage tank (UST) fueling systems in every day language. What you need to know about Texas Commission on Environmental Quality (TCEQ)
More informationModel 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS
Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS INSTALLATION INSTRUCTIONS UNIVERSAL VALVE COMPANY, INC. 478 SCHILLER ST. ELIZABETH, NJ 07206 Rev A
More informationDEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE
DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:
More informationBottom Load Adaptors. API Adaptors 891 Series. API Bottom Loading Adaptor L
Bottom Load Adaptors API Adaptors 891 Series API Adaptors are crucial to any API bottom loading system, the API Adaptor is precisely engineered and manufactured to match with a standard API coupler. Much
More informationLD Series Electronic Meters
LD Series Electronic Meters Manual and Preset Dispense Dispenses in gallons, quarts, pints and liters Easy to read LCD display with durable switches for long life Rugged engineered material for superior
More informationTank Filling Systems for Petroleum Products
for Petroleum Products Insight Onsite for Petroleum Products Page 2 What is it used for? Generally used with aboveground storage tanks, although some underground uses as well. What is it? An easy means
More informationINSTALLATION INSTRUCTIONS
A4005EVR Balance Vapor Recovery Nozzle RA4005EVR = Rebuilt XXX = Scuff Guard Color Permanent ID Information: Emco Logo on Boot Connector Emco Logo on Scuff Model No. on Spout Emco Wheaton Security Rivet
More informationClay & Bailey Mfg. Co.
Clay & Bailey Mfg. Co. OIL EQUIPMENT PRICE LIST 2015 Effective: February 9, 2015 Applicable for Aboveground Storage Tank Equipment Underground Storage Tank Equipment Service Station Equipment D. O. T.
More informationClay & Bailey Mfg. Co.
Clay & Bailey Mfg. Co. OIL EQUIPMENT PRICE LIST 2018 Effective: June 1, 2018 Applicable for Aboveground Storage Tank Equipment Underground Storage Tank Equipment Service Station Equipment D. O. T. Manholes
More informationEmergency Shear Valves
Emergency Shear Valves 0060 Underpump Emergency Valve The Emco Wheaton 0060 Emergency Shear Valve incorporates a replaceable shear section and a heat sensitive fusible link assembly. The valve can be manually
More informationSERVICE QUALITY PRODUCTS INNOV ATION CUST OM ASSEMBL Y ADVANCED PRODUCT TECHNOLOGY CATALOG
SE RV IC E Q UA LI TY PR O DU CT S I NN O VA TI O N C US TO M AS SE M BL Y A DV AN CE D TE CH NO LO G Y CATALOG PRODUCT S panning three centuries, Morrison Bros. Co. is among North America s oldest manufacturing
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2008 edition of NFPA 30A, and the 2006 International Fire Code (IFC). Please
More informationTHE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS
THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com
More informationPortable Fuel Dispensing Equipment
Portable Fuel Dispensing Equipment (Model 107 Fuel Conditioning Cart) (Model 106 Fuel Service Cart) Webber EMI offers a full line of fuel dispensing & handling equipment, from fuel conditioning drum carts,
More informationEmco Logo on Scuff INSTALLATION INSTRUCTIONS
For use with Vapor Systems Technologies VST California Air Resources Board Executive Orders VR-203 and VR-204 A4005EVR Balance Vapor Recovery Nozzle RA4005EVR = Rebuilt XXX = Scuff Guard Color Permanent
More informationRULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX
RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted 2-5-75 (Amended 9-15-75, 8-3-77, 9-2-80, 12-17-91, 2-2-95, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION:
More informationModel Model 815
Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............
More informationDefender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series
Defender Series Overfill Prevention Valve Automatic Shutoff for USTs Installation, Operation and Maintenance 708-590 Series For use in 4" gravity-fill applications only 25-370 Gallons per Minute flow Compatible
More informationInstructions for Installation, Operation, Care and Maintenance
Model D Dry Pipe Valve Bulletin 350 Rev. S Bulletin 350 Rev. S Instructions for Installation, Operation, Care and Maintenance 4 (100mm) 6 (150mm) Valve With Model D Trimmings Listed by Underwriters Laboratories,
More informationInstructions for Installation, Operation, Care and Maintenance
Bulletin 59 Model DDX Deluge Valve (50 mm), ½ (65 mm), (80 mm), 76 mm, 4 (00 mm), 6 (50 mm), 65 mm & 8 (00 mm) Bulletin 59 Instructions for Installation, Operation, Care and Maintenance Wet Pilot Line,
More informationPEI/RP Recommended Practices for Installation of Bulk Storage Plants
PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1
More information12 Volt DC Diaphragm Pumps Series 400
Page 1 of 6 12 Volt DC Diaphragm Pumps Series 400 More Information Index Description of Included Models Safety Listings Available Options Accessories Performance Flow Curve Fluid Compatibility Dimensions
More informationIndustrial Pumping Equipment Air-Operated Diaphragm Pumps
Industrial ing Equipment -Operated Diaphragm s 85630 85628 85622 85634 ¼" - 2" -Operated s Basic Design Features Diaphragm pumps are driven by compressed air.the directional air distribution valve and
More informationAC 700 SERIES FUEL PUMPS Item code: FILLRITE-AC700
AC 700 SERIES FUEL PUMPS Item code: FILLRITE-AC700 These rock solid pumps are ideal for use with Fuel Management Systems (FMS), making them perfect where monitoring fuel transfer is critical. The Fill
More informationOperating instructions Form no safety definitions
Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety
More informationInstructions Parts List
Instructions Parts List : RATIO Fast Flo Pump Air operated piston transfer pump for low viscosity fluids. For professional use only. Only models that are EX certified are approved for use in European explosive
More informationStay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event
Product Bulletin UPDATE: Executive Orders VR-201 and VR-202 Revision Q Field Reattachable EVR Vapor Assist Healy-Style Safety Breakaway 09.24.14 The release of Executive Orders VR-201 and VR-202 Revision
More information92021 Automatic Tank Gauge. Features. Automatic Tank Gauge. 1/16 Accuracy. 90 Foot gauging range. Simple installation. Ground or roof reading
92021 The Shand & Jurs 92021 Automatic Tank Level Gauge is a float actuated tape driven gauge and by means of a digital counter indicates float travel accurately to 1/16 inch. The 92021 meets all the specifications
More informationFast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. 07 7 Rev. Z Supersedes W Includes Rev. Y changes
More informationFR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps
Owners Installation, Operation, and Safety Manual FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps FR600G Series AC Transfer Pumps 1 Tuthill Transfer Systems 8825 Aviation Drive
More informationFluid Dispensing Systems
Fluid Dispensing Systems Automotive Commercial Industrial Centerflo Air Operated Double Diaphragm (AODD) Pumps Pumps Signature Series Product Selection Matrix MAX. FREE FLOW CF10 POLYPROPYLENE AIR INLET
More informationTECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications
Page 1 of 11 1. DESCRIPTION The Viking Model F-2 Dry Pipe Valve is a latching differential valve used to separate the water supply from the dry pipe sprinkler system. The valve combines a positive latching
More informationOPW 400 and 500 Series Multi-Port Spill Containment Manholes. Model Descriptions. Features. Listings and Certifications
FSA400 Model s u OPW 411 Series features a flushmounted manhole lid and raised dual dam and groove spill container rings, with P2105 Buckets using OPW 1-2105 Style Slip-On 5-gallon containers. Base is
More informationCAUTION: NOT INTENDED FOR STREET USE HOW TO USE THIS CATALOG WE LOVE RACING
WE LOVE RACING When WIX Filters began making its performancedriven products in 1939, the first Daytona race was still 20 years down the road. In developing the WIX Racing line, WIX engineers have worked
More information2 0 1 7 D E F E Q U I P M E N T C ATA L O G 608-487-9770 www.hartlandlubes.com TD1 Features & Benefits: Great performance and quiet operation Self priming Stainless steel motor shaft Polypropylene housing
More informationModel Model Model 3650 Model 3614
Model 3601 Model 3662 Model 3650 Model 3614 Model 3675 Portable used fluid handling equipment and fuel caddies Collection equipment pressurized (self-evacuating)....... 170 Upright drains.....................................
More informationDuplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover
www.cranepumps.com Duplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover Pre-Packaged Fiberglass Systems Specifications: inches (mm)
More information1/2" AIR DRIVEN DIAPHRAGM PUMP
1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of
More informationfunnels, measures, gravity cocks, jerry cans and oil suction pumps...
funnels, measures, gravity cocks, jerry cans and oil suction pumps lubrication AND ACCESSORIES grease nipples............................................................ GREASE CONNECTORS........................................................
More informationTECHNICAL DATA CAUTION
Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.
More informationM-3025CB-AV Fuel Pump
SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...
More informationOwner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES
Owner's Operation & Safety Manual SERIES 800C METER For models 806C, 807C Model 806C Model 807C OUTSTANDING FEATURES 5 to 20 GPM / 19 to 76 LPM flow rate ±1% accuracy 3/4" or 1" NPT flow ports Large, easy
More informationReliance G6200 Mechanical Fleet Dispenser
Reliance G6200 Mechanical Fleet Dispenser Dresser Wayne Reliance G6200 Series Mechanical Fleet Dispensers Fueling capabilities you can depend on down the road Keeping your fleet on the move depends on
More informationDual wall sub-base diesel fuel tanks -
Specification sheet Dual wall sub-base diesel fuel tanks - 10-125 kw generator sets Description Cummins offers two series of fuel tanks (basic series and regional series) for the 10~125 kw diesel generator
More informationOPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:
OPERATOR S MANUAL 650719-C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 8-11-03 REVISED: 12-3-10 (REV. 08) 2" DIAPHRAGM PUMP U.L. LISTED, 1:1 RATIO, METALLIC READ THIS MANUAL CAREFULLY BEFORE
More information.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.
Shoal Lake Intake Fuel Storage and Delivery System Rehabilitation Page 1 of 10 1. GENERAL 1.1 Scope.1 The following statement generally describes the scope of work covered by this Section. All tank volumes
More informationDEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE
DEFENDER SERIES 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model 705-543 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718
More informationInformational Handbook
Informational Handbook Print Date: September 2012 Krueger Sentry Gauge Co., Inc. 1873 Siesta Lane Green Bay, WI 54313-8021 Ph: 920-434-8860 Ph: 800-959-0371 Fax: 920-434-8897 Office Hours: 7:00 A.M. to
More informationSELECT TM SERIES ELECTRONIC FLEET FUEL DISPENSERS
SELECT TM SERIES ELECTRONIC FLEET FUEL DISPENSERS WFS140022-B_select_series_8pg_newdesign_07212014.indd 1 5/21/16 6:09 PM Wayne Select Series Electronic Fleet Fuel Dispensers Advanced technology delivers
More informationControl Valves/Meters Grease
Grease 740 WARNING Lincoln Control Valves, Meters and Accessories Provide the Durability and Precision You Need for Your Lubrication Systems. Whip Hoses Models 3029, 3034, 5812, 5818, 5861, 81725, 81726,
More information12V DC FUEL PUMPS Item code: FILLRITE-12V
12V DC FUEL PUMPS Item code: FILLRITE-12V The Fill-Rite versatile line of DC fuel transfer pumps are available with flows ranging from 13 GPM, to the industry best flow of 25 GPM. UL listed motors assure
More informationFR600G Series AC Transfer Pumps
Owners Installation, Operation, and Safety Manual FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps FR600G Series AC Transfer Pumps 1 Tuthill Transfer Systems 8825 Aviation Drive
More informationFueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems
Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems Operation Manual Fueltec Systems LLC 828-212-1141 www.fueltecsystems.com FEATURES Stainless steel filter housings to resist the acids found
More informationModel 5000 Level Controller
Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap
More informationPyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D
SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D 1 HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A fire fighting system shall
More informationFarm & Residential Tanks Angle skids
Farm & Residential Tanks Angle skids Multi-purpose, convenient, and economical fuel storage Each tank tested to ensure quality Engineered for strength and dependability Made with U.S. steel Tank listed
More informationIST INTELLIGENT SUBMERSIBLE TURBINE
INTELLIGENT SUBMERSIBLE TURBINE IST The FIRST Submersible Pump Ever Designed For High Volume Retailers. The NEW 4HP 4" Diameter Variable Speed Turbine. When FAST Fueling Means MORE Sales. THE IST... NOW
More informationAirless Sprayer. TriTech is PRECISION BUILT
Airless Sprayer T5 Airless Sprayer Specifications Max Pressure 3300 PSI (226 BAR) Max Tip 0.025 Max GPM 0.62 (2.36 LPM) Motor HP 1.1 HP Weight (Stand) 37 lbs (17Kg) (Lo-Cart) 67 lbs (30Kg) (Hi-Cart) 67
More informationInstructions for Installation, Operation, Care and Maintenance
Bulletin 407 Rev. T Model E Alarm Check Valve Bulletin 407 Rev. T Instructions for Installation, Operation, Care and Maintenance 4 (100 mm), 6 (150 mm), 8 (200 mm) Sizes With Model E3 Trim Listed by Underwriters
More informationM-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual
SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2
More informationPro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203
Pro 30 Gas Caddy Model Operator s Manual Contents Page Safety & Warning Instructions 2 General Product Description 3 Assembly 3 Operation 4 Storage 4 Product Specifications 4 Replacement Parts & Accessories
More informationHIGH PRESSURE SPRAYERS
S S STRAIGHT THROUGH QDS FITTINGS AND SWIVELS NOZZLES SPRAY GUNS AND WANDS 337 NOZZLES QUICK DISCONNECT NOZZLE 0-degree red tip nozzle, 15-degree yellow tip nozzle, 25-degree green tip nozzle, 40-degree
More informationControl Valves/Meters Grease
Grease 740 WARNING Whip Hoses Models 3029, 3034, 5812, 5818, 5861, 81725, 81726, 81795 Install as shown. Swivels Volume High-Pressure Swivels Model Description Thread Size 81728 Straight 1 /2" NPT(m) x
More information3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.
TITLE 41: FIRE PROTECTION CHAPTER I: OFFICE OF THE STATE FIRE MARSHAL PART 180 STORAGE, TRANSPORTATION, SALE AND USE OF GASOLINE AND VOLATILE OILS SECTION 180.20 ABOVEGROUND STORAGE DISPENSING Section
More informationCongratulations PRE-OPERATION SETUP
Congratulations on the purchase of your new ProVac Industrial Pumpout Station. Your new ProVac has been manufactured with the best quality components to give you year after year of trouble free service.
More informationSPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G
SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G Scope and General Design Requirements A firefighting system shall be provided for offensively attacking a fire.
More informationOPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:
OPERATOR S MANUAL 670042 INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 1-25-07 REVISED: 8-27-08 (REV. 02) 1/2" DIAPHRAGM PUMP U.L. LISTED, 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE
More informationDIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE
DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of
More informationConventional Fueling 11A 11B. 1A Automatic Nozzle
Conventional Fueling 11A The OPW 11 Series automatic nozzles are OPW s premium conventional nozzles for safe retail and commercial petroleum filling. The OPW 11 Series is the most trusted conventional
More informationSPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D
SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A firefighting system shall be
More informationSimplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover
www.cranepumps.com Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover Specifications: inches (mm) BASIN...Fiberglass w/ 3 (76)
More informationPolypropylene Piston Drum Pumps
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationExhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)
Exhibit 5 Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle) Definitions common to all certification and test procedures are in: D-200 Definitions for Vapor
More informationTECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11
Page 1 of 11 1. DESCRIPTION The Viking Model F-1 Dry Pipe Valve is a latching differential valve used to separate the water supply from the dry pipe sprinkler system. The valve combines a positive latching
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Packages Weather Enclosure Sound Enclosure Applicable to the following models: 650/750REOZDB Kohler enclosures protect
More informationPage 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location
SELECTOR GUIDE 6-1 AUTOMATIC AUTOMATIC X-STREAM SM-10FE AVAILABLE BASE 1.5 2.5 3.5 1.5 2.5 3.5 300-2000 (1136-7571) 20-120 (76-454) PRODUCT DESCRIPTION MATERIAL Page 6-6 Page 6-3 Simplifies fireground
More informationOPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS
OPERATION MANUAL 3 METALLIC PUMP (CLAMPED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF80 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models DUCTILE Models 316 S.S. Models A JDA Global Company CAUTIONS - READ
More informationVersa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar
Versa-Matic Operating Manual 3/8" Bolted Plastic Pumps Polypropylene Kynar E8 SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser
More informationHIGH PRESSURE SPRAY GUNS &ACCESSORIES
HIGH PRESSURE SPRAY GUNS &ACCESSORIES Max. PSI: 4000 PSI Max. GPM: 10 GPM Weight 18 oz. TEEJET PW4000 Built in hose swivel Max. PSI: 4000 PSI Max. GPM: 10 GPM Weight 18 oz. TEEJET PW4000 Max. PSI: 4000
More informationOil & Light Fluid Pumps
Oil & Light Fluid Pumps OilMaster Air Operated Pumps Features 2 adjustable bung adapter included Built-in pressure relief Quiet operation Low air consumption Compact design for tight installations Specifications
More informationFUELTEC MODEL CF4.0. CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters)
FUELTEC MODEL CF4.0 CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters) Today s diesel engines require aircraft quality fuel. Not to many years ago diesel engines were
More informationCONTENTS. Foreword...iii. 1. Introduction...1
Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1
More informationInstructions for Installation, Operation Care and Maintenance
Model A Dry Pipe Valve Bulletin 353 Rev.K Bulletin 353 Rev.K Instructions for Installation, Operation Care and Maintenance 2 1 2 (65mm) Valve With Model A Trim Listed by Underwriters Laboratories, Inc.
More informationWet pipe low flow foam/water manifold system
December 6, 2010 Foam 15a 1. Description With the Wet Pipe Low Flow Foam/Water Manifold System, multiple risers can be supplied from a single proportioning device. A riser manifold is installed with various
More information