FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

Size: px
Start display at page:

Download "FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System"

Transcription

1 FUEL DISPENSING SYSTEMS Component Details SE-27 12V DC - 15 GPM Metered Tank-top Dispensing System 12V DC Electric Pump - 1 Inlet - 3/4 Outlet 3-Wheel Mechanical Meter 1 Automatic Nozzle, Swivel & Hose 40 GPM Particulate Filter - 30 Micron 2 - Emergency Vents - MNPT - 16 oz Pop-up Leak Gauge Swing-arm or Clock Level Gauge Overfill Prevention Valve Atmospheric Vent with Pipe Drop Tube - Pump Suction Pipe - 3 Lift Spill Bowl or Remote Fill Maximum tank diameter 64 Proudly made in America

2 12V DC Electric Pump - 1" Inlet - 3/4" Outlet This industry standard DC pump dispenses up to 15 GPM (57 LPM). The FR1204G is ideal for pumping gas, diesel fuel and kerosene. With an amp draw that's easy on your DC power source. Explosion proof UL/cUL listed 1/4 HP motor. The FR1204G is a pump only unit allowing you to customize your own system. Please see our full line up of meters and accessories to complement your system. Features & Benefits Up to 15 GPM 1/4 HP motor UL/cUL listed motor Compatible with Diesel, Gasoline, Kerosene, E15, and Biodiesel up to B20 2 year warranty Built in strainer 2 in. threaded base for tank mounting Heavy duty cast iron construction Cast bronze rotor with bronze rotary vanes 1/4

3 3-Wheel Mechanical Meter The 807C Mechanical flow meter has a large easy to read display, flow ports can be positioned vertically or horizontally, UL/cUL listed, handles fluid of any viscosity, rated for Gasoline, Diesel, Kerosene, mineral spirits, Stoddard solvents and heptane. Fill Rite meters provide precision and durability in a cost effective design. The 807C is a 3 wheel mechanical meter designed for transfer pumps with a flow rate of 5 to 20 GPM. this meter has a 3/4 in. inlet and outlet. Features & Benefits +/ 1% accuracy UL/cUL, CE listed 5 20 GPM 50 PSI 3/4 in. inlet, 3/4 in. outlet Large easy to read display NPT threads tp:// 1/4

4 3/4" Automatic Nozzle, Swivel & Hose, Gas & Diesel The N Series nozzles are well suited for a broad range of high flow fueling applications from farm tractors and combines, heavy earth moving equipment, fleet re fueling, to above ground storage tanks and portable truck mounted fueling operations. This rugged series of automatic nozzles will provide years of service with minimal down time and quick fueling. Features & Benefits Compatible with diesel UL listed 3/4 in aluminum nozzle 3/4 in NPT F outlet Automatic shut off 50 PSI working pressure Green body cover to indicate diesel compatibility Heavy duty hanging hook compatible with all Fill Rite products Convenient one finger hold open clip to set flow rate ttp:// 1/4

5 3/4" Swivel & Hose Multi Plane, Full 360 spherical rotation for easy movement of the nozzle. Features & Benefits Double O ring Seals at each Swivel Provide Long Life at Low Temps ( 40 F/C) Compatible with unleaded Gasoline, Diesel & Ethanol Blends through E10 Dispense Diesel Fuel, Gasoline, Grease Kerosene and Petroleum Oils. The Fill Rite hose is a blend of Nitrile and PVC external materials provides rugged protection against cuts, abrasions, snags. Puncture Resistant. Features & Benefits 3/4 x 12' fuel transfer hose Dispense diesel fuel, gasoline, kerosene, and petroleum oils Neoprene exterior Designed for use with all electric pumps High quality Nitrile inner tube

6 18 GPM Particulate Filter - 10 Micron & Filter Head Particulate Fuel Dispenser Filter is designed with resin impregnated cellulose media for the removal of dirt, rust and microbes. Features & Benefits 10 Micron Filter 50 psi 18 gpm 1 12 UNF Compatible with gasoline, diesel, ethanol blends up to 15% and ultra low sulfur diesel

7 Emergency Vents - MNPT - 16 oz UL Listed Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire. Emergency vents must be used in conjunction with a normal vent. Correct application of this vent requires proper vent size and selection for the tank system in order to meet the specific venting capacity. Code Compliance: API 2000 International Fire Code National Fire Code of Canada NFPA 1, 30, 30A, 31, 37, 110 PEI RP200 & PEI RP800 Underwriters Laboratories Inc. - UL-142, UL-2085 & UL Underwriters Laboratories of Canada - CAN/ULC S601-07, CAN/ULC S & CAN/ULC S California Air Resource Board (CARB) Phase 1 Enhanced Vapor Recovery (EVR) AST Certified Products (VR-402-B) Fig. 244OM WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILL OPERATE PROPERLY. Emergency vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state, and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing temperatures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airfl ow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank.

8 Leak Gauge - Pop-Up Top mounted liquid leak gauge that can measure from 6" to 170" in depth. Gauges are custom made in house to fit your tank. This gauge is designed to monitor either the interstitial space of a double wall containment system, or it can mount into an external monitoring pipe. Calibration: Consists of 3 pieces. Outer plastic piece, inner plastic piece, and a piece of paper in between. Red Lock Nut: HDPE Plastic. This gauge is a simple visual tool. If the red indicator rises into the viewing window, it is indicating that there is a leak occurring in the double wall containment system. Bushing: Aluminum bushing, can be 2 or 1.5. Once installed, simply view the calibration to monitor the interstitial space. The indicator is not calibrated. It simply indicates leak or no leak. Internal Rods: Standard construction is aluminum rods. Additional Options Leak Union: Compression union Audible Alarm Accessory: This feature can turn the mechanical gauge into an audible Hi or Lo level alarm. Gauge Guard: A cover that protects the exposed plastic components on top of the gauge. Environmental Protection The Leak gauge is officially approved for use in double wall containment systems by several state environmental protection agencies. Float: HDPE Plastic

9 Level Gauge - Swing Arm Top mounted liquid level gauge that can measure from 6" to 144 in depth. This gauge is a simple volume reading tool. The top of the red indicator is an indication of approximate fuel level in the tank. Once installed, simply view the calibration to monitor tank level. Indicator is calibrated in eighths of a tank on one side, and quarters of a tank on the other. Calibration: Consists of 3 pieces. Outer plastic piece, inner plastic piece, and a piece of paper in between. Red Lock Nut: HDPE Plastic. Bushing: Aluminum bushing, can be 2 or 1.5. Gauges are custom made in house to fit your tank. Can also accommodate for double walls and pipe risers. HDPE Float: High Density Polyethylene Plastic. Additional Options Audible Alarm Accessory: This feature can turn the mechanical gauge into an audible Hi or Lo level alarm. LED At-A-Glance Accessory: This feature can give mechanical gauge remote reading capability. Gauge Guard: A cover that protects the exposed plastic components on top of the gauge. Internal Rods: Standard construction is galvanized steel rods with brass rivets. These replacement parts are available. Red HDPE Plastic Nut Duro Nitrile Gasket Plastic cellulose acetate inner and outer calibration Aluminum Lock Nut Glass inner calibration

10 Overfill Prevention Valve The overfill prevention valve is installed at the fill port of a storage tank. Used in a pressurized tight fill application, the valve helps prevent tank overfills by closing when the liquid level reaches a pre-set warning level (90-95% full). The valve is installed through a 4" or 6" threaded opening and has a built-in bleed hole that allows the fill hose pressure to be relieved after the valve closes. This bleed hole also provides anti-siphon protection for the valve. When installed to manufacturer requirements, the overfill prevention valve can eliminate hazardous liquid spills. The valve can be used in conjunction with AST spill containers or remote fill boxes for added spill protection. All models are supplied with an adaptor to mount an aluminum drop tube. A test mechanism is also sold separately if needed. The test mechanism allows a technician to pull on the test line at any time during the filling process to actuate the float and stop the filling process. This allows a technician to verify the valve is working properly. Features The 3" valve can be used with 6" Sch. 40 or 80 pipe. The 2" valves can only be used with 4" Sch. 40 pipe. Construction Details Anodized aluminum body Brass/stainless steel internal components Stainless steel linkage Failure to follow any or all of the warnings listed below may render the valve non-functional and could result in an accidental product spill, property damage, fire, explosion, injury or death. Warnings and Cautions 5 PSI & 5 GPM is the minimum flow requirement for valve operation. Valve will NOT function in gravity fill applications. Maximum viscosities (in centistokes): 2" Valve-150, 3" Valve-60. Flow rate of the 2" valve is 350 GPM maximum flow ( PSI pressure drop). The 3" valve is 800 GPM maximum flow rate ( PSI pressure drop). Once closed the valve will allow fl ow of less than 2% of max fl ow rate to relieve fill line pressure. A tight fill is required for the valve to operate. Do not substitute any other fill adaptors for the special adaptor supplied. The valve must be used with clean product. Debris from products such as contaminated used oil may cause the valve to function improperly. These valves are rated for a maximum pressure of 100 PSI. Not suitable for motor oil or other heavy oils. Consult Morrison Bros. Co. for product compatibility with the valve. Code Compliance ULC, NFPA 30, 30A, UFC, IFC and PEI /RP200, PEI /RP600, Florida DEP EQ356, CARB VR 402A

11 Drop Tube & Normal (Mushroom) Vent with Pipe The drop tube directs product flow to liquid level when filling a storage tank. The drop tube prevents free fill and reduces agitation of liquid when filling. The flanges fits between tight fill adaptor riser pipe. The tube extends to near bottom for submerged fill. All drop tubes are extruded aluminum. The 2 and 3 drop tubes can also be attached to the AST Overfill Prevention Valve. Drop tube length determined by tank diameter. Mushroom style free flow vent Stainless-steel mesh screen. Domed vent top prevents tank contamination from entering vent lines. NPT threads Cast iron, zinc plated 2" diameter galvanized steel vent pipe Length determined by tank volume/size

12 Spill Bowl Tank top spill containers are designed tocontain small spills that occur at the fill point on aboveground storage tanks. Features 3½ gallon (13.25 liters) capacity Hinged cover is lockable with a padlock Centered connection Female threaded inlet and outlet Includes removable screen for use as used oil collection point, male threads Construction Details 16 gauge spun steel, powder-coated white body and cover Capacity: 3.5 Gallons Mounting Connection: Female Mounting Location: Center Size: 2 NPT threads Drain: No Screen: No Height: 8 Width: Body diameter: Certifications & Listings Florida DEP EQ 345 Meets the new and revised requirements for CAN-ULC-S (effective September 25, 2015)

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-37 120V AC - 20 GPM Metered Tank-top Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter 1" Automatic Nozzle, Swivel

More information

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-47 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter in Cabinet 1 Automatic

More information

Fuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle

Fuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle Pumps 110300-2 DC Aluminum Gear Fuel Pump with Auto Nozzle 110300-2 12-Volt DC - Rotary Gear. Explosion Proof Motor. Up to 18 GPM (69 LPM) 12 ft. (3.7m) x 1 in. Hose 137100-01 EZ-8 DC Fuel Pump 137100-01

More information

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co. Aboveground Tank Equipment Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co. HISTORY Morrison Bros. Co. Then Founded in 1855 Located in Dubuque, Iowa Originally a boiler manufacturer

More information

ABOVEGROUND STORAGE TANK PRODUCTS CATALOG

ABOVEGROUND STORAGE TANK PRODUCTS CATALOG NEW PRODUCTS! ABOVEGROUND STORAGE TANK PRODUCTS CATALOG NEW UL Listing! High Flow Emergency Vents Emergency Valves Overfill Prevention Valves Audible Alarms Spill Containment Box Overfill Prevention Valves

More information

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent CARB Phase I Enhanced Vapor Recovery AST Certified Products 5 (VR-402-D) Sensor Pressure Vacuum 10 Monitoring 1 12 or 34 Clock Gauge Direct Fill Spill Container 6 9 2 Overfill Gauge Stick Port Prevention

More information

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent CARB Phase I Enhanced Vapor Recovery AST Certified Products 5 (VR-402-B) Sensor Pressure Vacuum 0 Monitoring Clock Gauge Direct Fill Spill Container Dust Cap 9 2 Overfill Prevention Gauge Stick Port Suction

More information

LUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading.

LUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading. hand grease guns Lever type The tough high pressure cast iron head makes Pro-Master Grease Guns unique in comparison to common pot metal or other die cast heads with a head burst pressure of 17,000 PSI

More information

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed. Series 600 AC Powered Pumps Model FR610C Pump Shown of Included Models Model Number FR610C FR611C Heavy Duty AC Utility Pump with 3/4" X 12' Hose & Nozzle, Telescoping Suction Pipe and 1/4 HP - 115 VAC/60

More information

AC 700 SERIES FUEL PUMPS Item code: FILLRITE-AC700

AC 700 SERIES FUEL PUMPS Item code: FILLRITE-AC700 AC 700 SERIES FUEL PUMPS Item code: FILLRITE-AC700 These rock solid pumps are ideal for use with Fuel Management Systems (FMS), making them perfect where monitoring fuel transfer is critical. The Fill

More information

LD Series Electronic Meters

LD Series Electronic Meters LD Series Electronic Meters Manual and Preset Dispense Dispenses in gallons, quarts, pints and liters Easy to read LCD display with durable switches for long life Rugged engineered material for superior

More information

Model 1210C Battery Powered Pump Shown

Model 1210C Battery Powered Pump Shown Page 1 of 6 PRODUCT DATA SHEET 12 Volt DC Rotary Vane Pump Series 1200C Description of Included Models Available Options Safety Listings Accessories Performance Flow Curve Fluid Compatibility Dimensions

More information

Tank Filling Systems for Petroleum Products

Tank Filling Systems for Petroleum Products for Petroleum Products Insight Onsite for Petroleum Products Page 2 What is it used for? Generally used with aboveground storage tanks, although some underground uses as well. What is it? An easy means

More information

Portable Fuel Dispensing Equipment

Portable Fuel Dispensing Equipment Portable Fuel Dispensing Equipment (Model 107 Fuel Conditioning Cart) (Model 106 Fuel Service Cart) Webber EMI offers a full line of fuel dispensing & handling equipment, from fuel conditioning drum carts,

More information

SERVICE QUALITY PRODUCTS INNOV ATION CUST OM ASSEMBL Y ADVANCED PRODUCT TECHNOLOGY CATALOG

SERVICE QUALITY PRODUCTS INNOV ATION CUST OM ASSEMBL Y ADVANCED PRODUCT TECHNOLOGY CATALOG SE RV IC E Q UA LI TY PR O DU CT S I NN O VA TI O N C US TO M AS SE M BL Y A DV AN CE D TE CH NO LO G Y CATALOG PRODUCT S panning three centuries, Morrison Bros. Co. is among North America s oldest manufacturing

More information

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS INSTALLATION INSTRUCTIONS UNIVERSAL VALVE COMPANY, INC. 478 SCHILLER ST. ELIZABETH, NJ 07206 Rev A

More information

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that

More information

Overfill Prevention Valve

Overfill Prevention Valve Overfill Prevention Valve The Guardian A1100 Materials Description Body: Aluminum Floats: HDPE Seals: Viton Specifications Weight: 4.3 lbs. Diameter: 3.76 Length: 18.0 Approvals CARB ULC City of New York

More information

FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps

FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps Owners Installation, Operation, and Safety Manual FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps FR600G Series AC Transfer Pumps 1 Tuthill Transfer Systems 8825 Aviation Drive

More information

Fuel Dispensing & Accessory Packages

Fuel Dispensing & Accessory Packages Fuel Dispensing & Accessory Packages HT-1150 Highland Tank Highland Tank provides turnkey solutions to fuel dispensing. In addition to a quality tank from the industry leader, Highland Tank can provide

More information

Model Model Model 3650 Model 3614

Model Model Model 3650 Model 3614 Model 3601 Model 3662 Model 3650 Model 3614 Model 3675 Portable used fluid handling equipment and fuel caddies Collection equipment pressurized (self-evacuating)....... 170 Upright drains.....................................

More information

12V DC FUEL PUMPS Item code: FILLRITE-12V

12V DC FUEL PUMPS Item code: FILLRITE-12V 12V DC FUEL PUMPS Item code: FILLRITE-12V The Fill-Rite versatile line of DC fuel transfer pumps are available with flows ranging from 13 GPM, to the industry best flow of 25 GPM. UL listed motors assure

More information

FR600G Series AC Transfer Pumps

FR600G Series AC Transfer Pumps Owners Installation, Operation, and Safety Manual FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps FR600G Series AC Transfer Pumps 1 Tuthill Transfer Systems 8825 Aviation Drive

More information

NOW UL LISTED. Patented

NOW UL LISTED. Patented NOW UL LISTED Patented Ø1.730 Ø 1.765 Ø.922 4.15 8.71 TOP VIEW 1.50 2" NPS THRDS. BOTTOM VIEW 2.13 2.14 SIDE VIEW 2.000 CLAY & BAILEY MFG. CO. 2" FILL SHUT OFF VALVE DATE:10/25/05 01228-03-2200 2" X 4"

More information

Model Model 815

Model Model 815 Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............

More information

Owner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES

Owner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES Owner's Operation & Safety Manual SERIES 800C METER For models 806C, 807C Model 806C Model 807C OUTSTANDING FEATURES 5 to 20 GPM / 19 to 76 LPM flow rate ±1% accuracy 3/4" or 1" NPT flow ports Large, easy

More information

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com

More information

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2008 edition of NFPA 30A, and the 2006 International Fire Code (IFC). Please

More information

1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions

1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions 1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions The 1618 Mechanical Gauge is designed to be used to measure liquid level in an aboveground storage tank. The gauge mounts to

More information

PROFESSIONAL GRADE FUEL TRANSFER PUMPS CATALOG

PROFESSIONAL GRADE FUEL TRANSFER PUMPS CATALOG PROFESSIONAL GRADE FUEL TRANSFER PUMPS 2014-15 CATALOG ENGINEERED TO DELIVER Extended Duty Cycles PRO20-012 Get more done in less time with the powerful PRO20-012 Extended Duty Cycle exceeds the industry

More information

Clay & Bailey Mfg. Co.

Clay & Bailey Mfg. Co. Clay & Bailey Mfg. Co. OIL EQUIPMENT PRICE LIST 2015 Effective: February 9, 2015 Applicable for Aboveground Storage Tank Equipment Underground Storage Tank Equipment Service Station Equipment D. O. T.

More information

General information about underground storage tank (UST) fueling systems in every day language.

General information about underground storage tank (UST) fueling systems in every day language. What this document contains: General information about underground storage tank (UST) fueling systems in every day language. What you need to know about Texas Commission on Environmental Quality (TCEQ)

More information

Dual wall sub-base diesel fuel tanks -

Dual wall sub-base diesel fuel tanks - Specification sheet Dual wall sub-base diesel fuel tanks - 10-125 kw generator sets Description Cummins offers two series of fuel tanks (basic series and regional series) for the 10~125 kw diesel generator

More information

Tank Filling Systems. for Petroleum Products

Tank Filling Systems. for Petroleum Products Tank Filling Systems for Petroleum Products Tank Filling Systems for Petroleum Products page 2 What Is It Used For? Generally used with aboveground storage tanks, although some underground uses as well.

More information

RELIANCE G6200 MECHANICAL FLEET DISPENSER

RELIANCE G6200 MECHANICAL FLEET DISPENSER RELIANCE G6200 MECHANICAL FLEET DISPENSER Wayne Reliance G6200 Series Mechanical Fleet Dispensers Fueling capabilities you can depend on down the road Keeping your fleet on the move depends on reliable,

More information

Clay & Bailey Mfg. Co.

Clay & Bailey Mfg. Co. Clay & Bailey Mfg. Co. OIL EQUIPMENT PRICE LIST 2018 Effective: June 1, 2018 Applicable for Aboveground Storage Tank Equipment Underground Storage Tank Equipment Service Station Equipment D. O. T. Manholes

More information

funnels, measures, gravity cocks, jerry cans and oil suction pumps...

funnels, measures, gravity cocks, jerry cans and oil suction pumps... funnels, measures, gravity cocks, jerry cans and oil suction pumps lubrication AND ACCESSORIES grease nipples............................................................ GREASE CONNECTORS........................................................

More information

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

Industrial Pumping Equipment Air-Operated Diaphragm Pumps Industrial ing Equipment -Operated Diaphragm s 85630 85628 85622 85634 ¼" - 2" -Operated s Basic Design Features Diaphragm pumps are driven by compressed air.the directional air distribution valve and

More information

Bottom Load Adaptors. API Adaptors 891 Series. API Bottom Loading Adaptor L

Bottom Load Adaptors. API Adaptors 891 Series. API Bottom Loading Adaptor L Bottom Load Adaptors API Adaptors 891 Series API Adaptors are crucial to any API bottom loading system, the API Adaptor is precisely engineered and manufactured to match with a standard API coupler. Much

More information

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series Defender Series Overfill Prevention Valve Automatic Shutoff for USTs Installation, Operation and Maintenance 708-590 Series For use in 4" gravity-fill applications only 25-370 Gallons per Minute flow Compatible

More information

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:

More information

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted 2-5-75 (Amended 9-15-75, 8-3-77, 9-2-80, 12-17-91, 2-2-95, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION:

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

LEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS FULL LINE OF QUALITY PRODUCTS MADE IN THE USA. Look for the red label! DOING BUSINESS SINCE 1972

LEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS FULL LINE OF QUALITY PRODUCTS MADE IN THE USA. Look for the red label! DOING BUSINESS SINCE 1972 LEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS MADE IN THE USA FULL LINE OF QUALITY PRODUCTS Look for the red label! DOING BUSINESS SINCE 1972 Great Plains Industries is a leading manufacturer of

More information

Emergency Shear Valves

Emergency Shear Valves Emergency Shear Valves 0060 Underpump Emergency Valve The Emco Wheaton 0060 Emergency Shear Valve incorporates a replaceable shear section and a heat sensitive fusible link assembly. The valve can be manually

More information

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment. Shoal Lake Intake Fuel Storage and Delivery System Rehabilitation Page 1 of 10 1. GENERAL 1.1 Scope.1 The following statement generally describes the scope of work covered by this Section. All tank volumes

More information

LT Series Lubricant Management System (LT-LMS)

LT Series Lubricant Management System (LT-LMS) FLUID HANDLING: LT Series Lubricant Management System (LT-LMS) This system combines filtration, storage, and breathers in one simple solution to keep your lubricants clean and dry. The Overview The LT-LMS:

More information

Model Model Model

Model Model Model Filter Separators Model 9003 Model 9004 Model 9001 & 9032 Model 9002 EXAIR's Filter Separators remove water, dirt and rust from your compressed air system. They prevent these contaminants from plugging

More information

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part. TITLE 41: FIRE PROTECTION CHAPTER I: OFFICE OF THE STATE FIRE MARSHAL PART 180 STORAGE, TRANSPORTATION, SALE AND USE OF GASOLINE AND VOLATILE OILS SECTION 180.20 ABOVEGROUND STORAGE DISPENSING Section

More information

FR310V Parts List WARNING! DO NOT

FR310V Parts List WARNING! DO NOT FR30V Parts List 60 2 62 WARNING! DO NOT open or attempt to repair the motor on your Fill-Rite pump. Return it to the place of purchase for service. Opening the motor can compromise the integrity of the

More information

Owners Installation, Operation, and Safety Manual. Series 300V. Fuel Transfer Pump. Series 300V 115 and 230 VOLT AC

Owners Installation, Operation, and Safety Manual. Series 300V. Fuel Transfer Pump. Series 300V 115 and 230 VOLT AC Owners Installation, Operation, and Safety Manual Series 300V Fuel Transfer Pump Series 300V 5 and 230 VOLT AC Tuthill Corporation 8825 Aviation Drive Ft. Wayne, IN 46809 (260) 747-7529 www.tuthill.com

More information

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203 Pro 30 Gas Caddy Model Operator s Manual Contents Page Safety & Warning Instructions 2 General Product Description 3 Assembly 3 Operation 4 Storage 4 Product Specifications 4 Replacement Parts & Accessories

More information

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

PEI/RP Recommended Practices for Installation of Bulk Storage Plants PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1

More information

92021 Automatic Tank Gauge. Features. Automatic Tank Gauge. 1/16 Accuracy. 90 Foot gauging range. Simple installation. Ground or roof reading

92021 Automatic Tank Gauge. Features. Automatic Tank Gauge. 1/16 Accuracy. 90 Foot gauging range. Simple installation. Ground or roof reading 92021 The Shand & Jurs 92021 Automatic Tank Level Gauge is a float actuated tape driven gauge and by means of a digital counter indicates float travel accurately to 1/16 inch. The 92021 meets all the specifications

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

Congratulations PRE-OPERATION SETUP

Congratulations PRE-OPERATION SETUP Congratulations on the purchase of your new ProVac Industrial Pumpout Station. Your new ProVac has been manufactured with the best quality components to give you year after year of trouble free service.

More information

FLUID HANDLING: Drum Filter Cart

FLUID HANDLING: Drum Filter Cart FLUID HANDLING: Drum Filter Cart This cart is ideal for pre-cleaning, protecting, and transferring oil from a conveniently attachable, secured drum. A drum adapter kit with a desiccant breather is included

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS A4005EVR Balance Vapor Recovery Nozzle RA4005EVR = Rebuilt XXX = Scuff Guard Color Permanent ID Information: Emco Logo on Boot Connector Emco Logo on Scuff Model No. on Spout Emco Wheaton Security Rivet

More information

Informational Handbook

Informational Handbook Informational Handbook Print Date: September 2012 Krueger Sentry Gauge Co., Inc. 1873 Siesta Lane Green Bay, WI 54313-8021 Ph: 920-434-8860 Ph: 800-959-0371 Fax: 920-434-8897 Office Hours: 7:00 A.M. to

More information

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers Dual Check w/ Atmospheric Port DCAP Series DUAL CHECK WITH ATMOSPHERIC PORT BACKFLOW PREVENTER The Apollo DCAP Series Backflow Preventer is designed to protect residential and commercial water supply lines

More information

FUELTEC MODEL CF4.0. CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters)

FUELTEC MODEL CF4.0. CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters) FUELTEC MODEL CF4.0 CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters) Today s diesel engines require aircraft quality fuel. Not to many years ago diesel engines were

More information

CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters)

CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters) CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters) Overview Model CF4.0-PLC The Model 4.0-PLC is a fuel polishing system that automatically removes water and debris to

More information

Operation, Installation, Maintenance and Repair Guide. HighFlo (HF) Control Handle. SERVICE BULLETIN SB 3097 Rev. A 6/14

Operation, Installation, Maintenance and Repair Guide. HighFlo (HF) Control Handle. SERVICE BULLETIN SB 3097 Rev. A 6/14 SERVICE BULLETIN SB 3097 Rev. A 6/14 HighFlo (HF) Control Handle Model 3320-051...HF Non-Metered Control Handle w/rigid extension, Semi-Auto tip, & 3/4 Swivel Model 3320-052... HF Non-Metered Control Handle

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 59 Model DDX Deluge Valve (50 mm), ½ (65 mm), (80 mm), 76 mm, 4 (00 mm), 6 (50 mm), 65 mm & 8 (00 mm) Bulletin 59 Instructions for Installation, Operation, Care and Maintenance Wet Pilot Line,

More information

Farm & Residential Tanks Angle skids

Farm & Residential Tanks Angle skids Farm & Residential Tanks Angle skids Multi-purpose, convenient, and economical fuel storage Each tank tested to ensure quality Engineered for strength and dependability Made with U.S. steel Tank listed

More information

2 0 1 7 D E F E Q U I P M E N T C ATA L O G 608-487-9770 www.hartlandlubes.com TD1 Features & Benefits: Great performance and quiet operation Self priming Stainless steel motor shaft Polypropylene housing

More information

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11 Page 1 of 11 1. DESCRIPTION The Viking Model F-1 Dry Pipe Valve is a latching differential valve used to separate the water supply from the dry pipe sprinkler system. The valve combines a positive latching

More information

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual DC V GPM Fuel Transfer Pump Kit User s Manual Distributed by: TRACTOR SUPPLY COMPANY 0 VIRGINIA WAY BRENTWOOD, TN 0 For customer support, call: ---90 www.tractorsupply.com MADE IN CHINA MODEL NUMBER: 0

More information

Portable Filter Carts Models 5MF and 10MF

Portable Filter Carts Models 5MF and 10MF s Models 5MF and 10MF 161 Applications for Parker Filter Carts Filtering new fluid before putting into service Transferring fluid from drums or storage tanks to system reservoirs Conditioning fluid that

More information

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart Instruction & Parts Manual This Manual Covers P/N 33271 P/N 33271

More information

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT FEATURES Compact design, high fl ow rates Visual position indicator standard For temperatures from 22 F to +430 F / -30 C to 221 C Working pressures up

More information

PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843

PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843 BID ADDENDUM NO. 1 PROJECT: PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843 LABELLA PROJECT NO: 2160128 DATE: FEBRUARY 11, 2016 FROM: LaBella

More information

Instructions Parts List

Instructions Parts List Instructions Parts List : RATIO Fast Flo Pump Air operated piston transfer pump for low viscosity fluids. For professional use only. Only models that are EX certified are approved for use in European explosive

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Model D Dry Pipe Valve Bulletin 350 Rev. S Bulletin 350 Rev. S Instructions for Installation, Operation, Care and Maintenance 4 (100mm) 6 (150mm) Valve With Model D Trimmings Listed by Underwriters Laboratories,

More information

M-1115S Series Fuel Pump

M-1115S Series Fuel Pump SAVE THESE INSTRUCTIONS M-1115S Series Fuel Pump Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...3 Operation...4 Maintenance...5 Repair...5 Troubleshooting...9

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Packages Weather Enclosure Sound Enclosure Applicable to the following models: 650/750REOZDB Kohler enclosures protect

More information

ACCESSORIES. Adaptor for ex100 spin-on ex100 UL/ULC Spin-on filter complete 10 µm, 17 gph UL/ULC Spin-on element 10micron for EX200 UL/ULC

ACCESSORIES. Adaptor for ex100 spin-on ex100 UL/ULC Spin-on filter complete 10 µm, 17 gph UL/ULC Spin-on element 10micron for EX200 UL/ULC ACCESSORIES SPIN-ON FILTER: 10 MICRON, 17 GPH WITH NPT PIPE CONNECTIONS (40 PSI MAX) The spin-on filter helps to increase your heating system s efficiency and to protect your furnace s burner. The element

More information

Stay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event

Stay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event Product Bulletin UPDATE: Executive Orders VR-201 and VR-202 Revision Q Field Reattachable EVR Vapor Assist Healy-Style Safety Breakaway 09.24.14 The release of Executive Orders VR-201 and VR-202 Revision

More information

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: OPERATOR S MANUAL 650719-C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 8-11-03 REVISED: 12-3-10 (REV. 08) 2" DIAPHRAGM PUMP U.L. LISTED, 1:1 RATIO, METALLIC READ THIS MANUAL CAREFULLY BEFORE

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi)  Stainless Steel  Polymer AKRON BRASS COMPANY PH. 800.228.1161 (330.264.5678) akronbrass.com Heavy Duty Brass Swing-Out Valves Akron Brass offers a wide variety of apparatus valves to meet the demands of today s fire service. All

More information

12 Volt DC Diaphragm Pumps Series 400

12 Volt DC Diaphragm Pumps Series 400 Page 1 of 6 12 Volt DC Diaphragm Pumps Series 400 More Information Index Description of Included Models Safety Listings Available Options Accessories Performance Flow Curve Fluid Compatibility Dimensions

More information

07 Oil Change & Diesel Transfer Pumps

07 Oil Change & Diesel Transfer Pumps 064 07 Oil Change & Diesel Transfer Pumps OIL CHAngE PuMPS Porta-Quick The Porta-Quick Portable Oil Changer makes quick, clean and easy oil changes onboard any boat, because it uses the vessel s own power

More information

FLUID HANDLING: Drum Filter Cart

FLUID HANDLING: Drum Filter Cart FLUID HANDLING: Drum Filter Cart This cart is ideal for pre-cleaning, protecting, and transferring oil from a conveniently attachable, secured drum. A drum adapter kit with a desiccant breather is included

More information

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems Operation Manual Fueltec Systems LLC 828-212-1141 www.fueltecsystems.com FEATURES Stainless steel filter housings to resist the acids found

More information

Emco Logo on Scuff INSTALLATION INSTRUCTIONS

Emco Logo on Scuff INSTALLATION INSTRUCTIONS For use with Vapor Systems Technologies VST California Air Resources Board Executive Orders VR-203 and VR-204 A4005EVR Balance Vapor Recovery Nozzle RA4005EVR = Rebuilt XXX = Scuff Guard Color Permanent

More information

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications Page 1 of 11 1. DESCRIPTION The Viking Model F-2 Dry Pipe Valve is a latching differential valve used to separate the water supply from the dry pipe sprinkler system. The valve combines a positive latching

More information

O-Ring Swivel Joints

O-Ring Swivel Joints O-Ring Swivel Joints O-Ring Parts Identification List 1. O-ring (dust) seal 2. ball retainer screw 3. O-ring (pressure) seal 4. grease fitting 5. ball bearings O-Ring he O-ring pressure seal ensures a

More information

Fluid Dispensing Systems

Fluid Dispensing Systems Fluid Dispensing Systems Automotive Commercial Industrial Centerflo Air Operated Double Diaphragm (AODD) Pumps Pumps Signature Series Product Selection Matrix MAX. FREE FLOW CF10 POLYPROPYLENE AIR INLET

More information

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2

More information

Control valves, meters and accessories

Control valves, meters and accessories Control valves, meters and accessories Control valves....................................... 48 Grease.......................................... 48 Fluid lubricants....................................

More information

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. Elecronic Preset Meter 2 Industrial Handheld Series Model EPM2-IND Standard Series IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. IOM-139-02-EN (1-12) 53400-139 Rev.

More information

Oil & Light Fluid Pumps

Oil & Light Fluid Pumps Oil & Light Fluid Pumps OilMaster Air Operated Pumps Features 2 adjustable bung adapter included Built-in pressure relief Quiet operation Low air consumption Compact design for tight installations Specifications

More information

CONTENTS. Foreword...iii. 1. Introduction...1

CONTENTS. Foreword...iii. 1. Introduction...1 Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1

More information

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. 07 7 Rev. Z Supersedes W Includes Rev. Y changes

More information

HIGH PRESSURE SPRAY GUNS &ACCESSORIES

HIGH PRESSURE SPRAY GUNS &ACCESSORIES HIGH PRESSURE SPRAY GUNS &ACCESSORIES Max. PSI: 4000 PSI Max. GPM: 10 GPM Weight 18 oz. TEEJET PW4000 Built in hose swivel Max. PSI: 4000 PSI Max. GPM: 10 GPM Weight 18 oz. TEEJET PW4000 Max. PSI: 4000

More information

Calcium Chloride Pump

Calcium Chloride Pump Parts List For Calcium Chloride Pump Model 10509 Calcium Chloride Pump ITEM PART NO. ITEM PART NO. NO. NO. REQ D DESCRIPTION NO. NO. REQ D DESCRIPTION 1 10537 2 Calcium Hose 10 x ¾ x 1 13 10565 1 Nipple,

More information

EZ-View. Flow Meters ISO CERTIFIED 9001

EZ-View. Flow Meters ISO CERTIFIED 9001 EZ-View ISO CERTIFIED 9001 General Design Features OPERATING PRINCIPLE The EZ-View Flow Meter is a variable-area instrument. A precisionmolded, sharp-edged Orifice, located within the Piston Assembly,

More information

Operating instructions Form no safety definitions

Operating instructions Form no safety definitions Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety

More information

CAT 401. North American Version PUMPS & ACCESSORIES

CAT 401. North American Version PUMPS & ACCESSORIES CAT 401 North American Version PUMPS & ACCESSORIES CONTENTS For more information Visit: www.groz-tools.com Call: 888-685-2916 ELECTRIC FUEL PUMPS HEAVY DUTY ELECTRIC FUEL PUMPS 4 HEAVY DUTY HIGH FLOW

More information