Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.
|
|
- Kelley Burke
- 5 years ago
- Views:
Transcription
1 Aboveground Tank Equipment Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.
2 HISTORY Morrison Bros. Co. Then Founded in 1855 Located in Dubuque, Iowa Originally a boiler manufacturer Then began manufacturing equipment for the oil industry Founder of Morrison Bros. Co.
3 HISTORY Morrison Bros. Co. Now Leader in AST products Produce more than 1,200 different products Include equipment for ASTs, USTs & service stations, environmental applications and tank trucks. Employ approximately 130 people in Dubuque & Maquoketa, Iowa locations. Morrison Bros. Co. Corporate Headquarters
4 TANKS Equipment for Shop-Fabricated Tanks Shop-fabricated tanks are small enough to be produced in a tank manufacturing plant and delivered to the site. Underwriters Laboratories UL 142 Underwriters Laboratories UL 2085 American Petroleum Institute API 650 American Petroleum Institute API 12F
5 TANK EQUIPMENT FILLING VENTING ANTI-SIPHON
6 TANK DISCHARGES
7 TANK FILLING Methods for preventing overfilling and spills from shop fabricated aboveground storage tanks. 1. Tank Gauging 2. Spill Containers 3. Alarm Systems 4. Overfill Protection Valves
8 TANK FILLING Tank Gauging
9 TANK FILLING Level Gauges Mechanical Gauges Liquid Level Gauge: Reads in feet and inches Liquid Level Gauge: Reads in Gallons
10 TANK FILLING Level Gauges Electronic Gauges Liquid Level Gauge
11 TANK FILLING Spill Containers
12 TANK FILLING Spill Containers-Top Fill Direct Top Fill
13 TANK FILLING Spill Containers -Top Fill
14 TANK FILLING Spill Containers-Remote Filling Remote Fill
15 TANK FILLING Connections Cam & Groove Dry Disconnect Cam & Groove with Check Valves
16 TANK FILLING Connections Tight-fill Delivery Connection
17 TANK FILLING Remote Fill Check Valves Swing Check In-line Check Wafer Check
18 TANK FILLING Remote Fill Block Valves Gate Valves Ball Valves
19 TANK FILLING Alarm Systems
20 TANK FILLING Alarm Panels AC Powered Alarm Systems 918AC System Interface AC-powered Monitor 1 to 4 intrinsically safe input switch devices Audible and visual alarm indicators
21 TANK FILLING Alarm Panels Battery Alarm Systems
22 TANK FILLING High Level Alarm Probes 924 (Brass) 924S (Stainless Steel)
23 VENTING Level Gauges & Alarm Panel
24 TANK FILLING Overfill Protection Valves
25 TANK FILLING Overfill Prevention Valves
26 TANK FILLING Overfill Prevention Valves Control Line Orifice Valve Body Hydraulic Piston Float (open position)
27 TANK FILLING Overfill Prevention Valves Manual Test Device
28 TANK FILLING Drop Tube Drop Tube
29 TANK FILLING Vapor Recovery Equipment
30 TANK FILLING Vapor Recovery Equipment
31 TANK EQUIPMENT ANTI-SIPHON
32 TANK DISPENSING Types of Dispensing Systems Pressurized Suction
33 TANK DISPENSING Pressurized System Dispensing through a Pressurized System
34 TANK DISPENSING Suction System Dispensing through a Suction System
35 TANK DISPENSING Generator & Heating Oil Supply
36 TANK DISPENSING Anti-Siphon: Mechanical Valves
37 TANK DISPENSING Anti-Siphon: Electric Solenoid Valves
38 TANK DISPENSING Anti-Siphon: Electric Solenoid Valves Piloted Operated Zero Differential with Hung Piston De-Energized Energized
39 TANK DISPENSING Thermal Expansion CLOSED
40 TANK DISPENSING Thermal Expansion
41 TANK DISPENSING Emergency Valves
42 TANK EQUIPMENT VENTING
43 TANK FILLING Emergency Venting
44 VENTING Emergency Venting
45 VENTING Emergency Venting Types of Emergency Vents 1. Pop-Up Style 2. Flip-Up Style 3. Long-Bolt Manway 4. Rupture Disk
46 VENTING Emergency Venting UL 2583 Emergency Vents UL 2583, an Outline of Investigation for Fuel Tank Accessories, is a revised testing protocol in which emergency vents have been given their own section and set of requirements. This is an update from the previous listing requirements to include modern automotive fuel compatibility and establish a standard testing protocol. Effective January 1, 2015
47 VENTING Emergency Venting UL 2583 D975 Diesel (Max B5) D7467 Low Blend Biodiesel (Max D20) D4814 Low Blend Ethanol (Max E10) D5798 High Blend Ethanol (E51-E83) D4814/D5798 Mid Range Ethanol (E11-E50)
48 VENTING Emergency Venting
49 VENTING Emergency Venting Emergency Venting Operation
50 TANK FILLING Normal Venting
51 VENTING Normal Venting
52 VENTING Normal Venting o Open vent allows free movement of air in and out of tank. Rain hood keeps water out. Vent height determined by authority having jurisdiction. Screen keeps bugs and debris out of tank. Vents outward and upward.
53 VENTING Normal Venting o Pressure/Vacuum Vent (Conservation Vent) Typical setting 2 oz. 8 oz. Pressure/1 oz. Vacuum. Conserves product and reduces vapor discharge. Vents outward and upward. UL 2583
54 VENTING Normal Venting Normal vents are very important
55 VENTING Normal Venting Flame Arrester Prevents the transmission of heat and/or an ignition source into the tank. Open Vent Arrester Pressure Vacuum Vent Arrester
56 Aboveground Tank Equipment Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.
PEI/RP Recommended Practices for Installation of Bulk Storage Plants
PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1
More informationFUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System
FUEL DISPENSING SYSTEMS Component Details SE-47 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter in Cabinet 1 Automatic
More informationFUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System
FUEL DISPENSING SYSTEMS Component Details SE-27 12V DC - 15 GPM Metered Tank-top Dispensing System 12V DC Electric Pump - 1 Inlet - 3/4 Outlet 3-Wheel Mechanical Meter 1 Automatic Nozzle, Swivel & Hose
More informationER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent
CARB Phase I Enhanced Vapor Recovery AST Certified Products 5 (VR-402-B) Sensor Pressure Vacuum 0 Monitoring Clock Gauge Direct Fill Spill Container Dust Cap 9 2 Overfill Prevention Gauge Stick Port Suction
More informationFUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System
FUEL DISPENSING SYSTEMS Component Details SE-37 120V AC - 20 GPM Metered Tank-top Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter 1" Automatic Nozzle, Swivel
More informationER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent
CARB Phase I Enhanced Vapor Recovery AST Certified Products 5 (VR-402-D) Sensor Pressure Vacuum 10 Monitoring 1 12 or 34 Clock Gauge Direct Fill Spill Container 6 9 2 Overfill Gauge Stick Port Prevention
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that
More informationChanges to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017
Changes to Chapter 62-761, Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017 Rule Organization The rule sections are reorganized a bit with separate sections now for:
More informationTHE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS
THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com
More informationCONTENTS. Foreword...iii. 1. Introduction...1
Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1
More informationNOW UL LISTED. Patented
NOW UL LISTED Patented Ø1.730 Ø 1.765 Ø.922 4.15 8.71 TOP VIEW 1.50 2" NPS THRDS. BOTTOM VIEW 2.13 2.14 SIDE VIEW 2.000 CLAY & BAILEY MFG. CO. 2" FILL SHUT OFF VALVE DATE:10/25/05 01228-03-2200 2" X 4"
More information3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.
TITLE 41: FIRE PROTECTION CHAPTER I: OFFICE OF THE STATE FIRE MARSHAL PART 180 STORAGE, TRANSPORTATION, SALE AND USE OF GASOLINE AND VOLATILE OILS SECTION 180.20 ABOVEGROUND STORAGE DISPENSING Section
More informationLorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA
Lorri Grainawi Steel Tank Institute PA NISTM April 25, 2013 Harrisburg, PA PEI/RP1200-12 ------------------------------------------------------ 1. Introduction 2. Definitions 3. Safety 4. Tank Secondary
More information.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.
Shoal Lake Intake Fuel Storage and Delivery System Rehabilitation Page 1 of 10 1. GENERAL 1.1 Scope.1 The following statement generally describes the scope of work covered by this Section. All tank volumes
More informationCode Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations
Code Requirements What follows is a detailed chart developed by Steel Tank Institute s executive vice president, Wayne Geyer, P.E. Fire codes play a prominent role in tank purchase decisions. As such,
More informationWinning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac
Minimum Specifications/Questionnaire Bid Results for One (1) New Fuel Dispensing System-Larrabee Shop Winning Bid PERMIT FEES, FORMS, PLANS and NOTIFICATIONS Secure all necessary state and local permits
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2008 edition of NFPA 30A, and the 2006 International Fire Code (IFC). Please
More information9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide
- Design Guides A. SITE PLANS: Provide existing condition, removal plan, and proposed installation site plans for all tanks. Plans must include the following: 1. Dimensions of tank and any structural pads.
More informationABOVEGROUND STORAGE TANK PRODUCTS CATALOG
NEW PRODUCTS! ABOVEGROUND STORAGE TANK PRODUCTS CATALOG NEW UL Listing! High Flow Emergency Vents Emergency Valves Overfill Prevention Valves Audible Alarms Spill Containment Box Overfill Prevention Valves
More informationSECTION VEHICLE FUEL DISPENSING EQUIPMENT
SECTION 23 10 13 PART 1 GENERAL 1.01 SUMMARY A. Provide vehicle fuel storage and dispensing equipment, including but not necessarily limited to: 1. Two compartment above ground gasoline and diesel tank.
More informationUnderstanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety
Understanding the Colorado Annual Compliance Package William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety Overview Required Documentation: UST / AST Annual Compliance Package Release
More informationOverview of Revisions to the Federal Underground Storage Tank (UST) Regulations. Storage Tank Advisory Committee Harrisburg, PA September 1, 2015
Overview of Revisions to the Federal Underground Storage Tank (UST) Regulations Storage Tank Advisory Committee Harrisburg, PA September 1, 2015 Why is EPA making changes to the UST regulations? The Energy
More informationearth safe Fuel Systems for Critical Power
Fuel System Control Valves 100 Solenoid Valves 110 Solenoid Valve Slow Close 120 Actuated Ball Valves 123 Actuated Ball Valves 3-Way 130 Actuated Butterfly Valves 140 Fire Safety Fusible Link Valves 145
More informationModel 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS
Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS INSTALLATION INSTRUCTIONS UNIVERSAL VALVE COMPANY, INC. 478 SCHILLER ST. ELIZABETH, NJ 07206 Rev A
More informationChanges to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC
Changes to EPA s AST & UST Rules Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith Consulting Group, LLC 111 North Calhoun Street, Tallahassee, FL 32301 marshall@mott-smithconsulting.com
More informationPREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843
BID ADDENDUM NO. 1 PROJECT: PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843 LABELLA PROJECT NO: 2160128 DATE: FEBRUARY 11, 2016 FROM: LaBella
More informationANNUAL UST SYSTEM INSPECTION CHECKLIST
APPENDIX A-3: SAMPLE FORM FOR ANNUAL UNDERGROUND STORAGE SYSTEM INSPECTION CHECKLIST Page 1 ANNUAL UST SYSTEM INSPECTION CHECKLIST Facility ID# Facility Name/Address Qualified Technician Signature Date
More informationFACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST
FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL On January 26, 2005, the Maryland Department of the Environment (the Department) implemented, in the Code of Maryland Regulations (COMAR) 26.10,
More informationNew UST Installation Inspection Checklist
Nebraska State Fire Marshal Fuels Division - FLST Section 246 South 14 TH Street - Lincoln, NE 68508-1804 (402) 471-9466 New UST Installation Inspection Checklist (Petroleum or Hazardous Substances) Inspection
More informationGeneral information about underground storage tank (UST) fueling systems in every day language.
What this document contains: General information about underground storage tank (UST) fueling systems in every day language. What you need to know about Texas Commission on Environmental Quality (TCEQ)
More information(Please type or use black ink)
(Please type or use black ink) PNIPUG ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT NOTICE OF PROPOSED UST NEW INSTALLATION OR UPGRADE (Use a separate form for each separate place of operation) Date of
More informationField-Erected AST Secondary Containment Options. Mott-Smith Consulting Group, LLC
Field-Erected AST Secondary Containment Options Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith Consulting Group, LLC National Technical Expert and Regulatory Liaison, AET
More informationClay & Bailey Mfg. Co.
Clay & Bailey Mfg. Co. OIL EQUIPMENT PRICE LIST 2015 Effective: February 9, 2015 Applicable for Aboveground Storage Tank Equipment Underground Storage Tank Equipment Service Station Equipment D. O. T.
More informationUnderground Storage Tank Annual Compliance Inspection (Revised 1/2015)
Colorado Department of Labor and Employment Division of Oil and Public Safety Compliance Section 633 17 th Street, Suite 500 Denver, CO 80202-3610 Phone: 303-318-8525 Fax: 303-318-8518 Email: cdle_oil_inspection@state.co.us
More informationClay & Bailey Mfg. Co.
Clay & Bailey Mfg. Co. OIL EQUIPMENT PRICE LIST 2018 Effective: June 1, 2018 Applicable for Aboveground Storage Tank Equipment Underground Storage Tank Equipment Service Station Equipment D. O. T. Manholes
More informationPortable Fuel Dispensing Equipment
Portable Fuel Dispensing Equipment (Model 107 Fuel Conditioning Cart) (Model 106 Fuel Service Cart) Webber EMI offers a full line of fuel dispensing & handling equipment, from fuel conditioning drum carts,
More informationNew UST Regulations. What follows are the changes to EPA s regulations that TMS believes impacts you, the owner/operator, the most.
New UST Regulations The long awaited UST regulations were released by the EPA on June 22, 2015 and soon will be published in the Federal Register. The new regulations will go into effect 90 days after
More informationEarthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard
Copyright 2008 Earthsafe Systems, Inc. This information is provided to consulting engineers and prospective customers for the purpose of specifying Earthsafe Emergency Power Fuel Systems. Reproduction
More information40 CFR 63, Subpart CCCCCC
0 CFR 3, Subpart CCCCCC The Unmatched Solution to Meeting U.S. EPA National Emissions Standards for New National Emission Standards have gone into effect for Hazardous Air Pollutants at Gasoline-Dispensing
More informationYork J Model Compressors Unloading Characteristics Styles A-F Solenoid Valve
Styles A-F Solenoid Valve Loaded - De-energized Crankcase Access Cover Oil Pressure Supply Oil Supply Valve Spring, Washer/Keeper Valve Rod and Disk To Unloading Cylinder Plunger Plunger Disk Crankcase
More informationTank Filling Systems for Petroleum Products
for Petroleum Products Insight Onsite for Petroleum Products Page 2 What is it used for? Generally used with aboveground storage tanks, although some underground uses as well. What is it? An easy means
More informationOperational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities
Connecticut Department of Energy and Environmental Protection Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities May 15, 2015 Peter Zack, Assistant
More informationFINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit
FINAL UNDERGROUND STORAGE TANK RULE CHANGES Heather Peters UST Compliance and Technology Unit Regulation Changes Federal Rule Based Changes Federal Regulations finalized in July 2015 Federal Rules effective
More informationDual wall sub-base diesel fuel tanks -
Specification sheet Dual wall sub-base diesel fuel tanks - 10-125 kw generator sets Description Cummins offers two series of fuel tanks (basic series and regional series) for the 10~125 kw diesel generator
More informationPEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems
PEI/RP900-08 Recommended Practices for the Inspection and Maintenance of UST Systems Recommended Practices for the Inspection and Maintenance of UST Systems CONTENTS Foreword...iii SECTIONS 1. Introduction
More informationSECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS
SECTION 22 11 23.13 (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Packaged Domestic Water Booster Pumps B. Related Sections: 1.02 REFERENCES 1. Section
More informationNYSDEC CBS Compliance Requirements
NYSDEC CBS Compliance Requirements Peter J. Petriccione, P.E. H2M - Water September 24, 2015 Introduction Definition of a Hazardous Substance and a Chemical Bulk Storage Facility Design Requirements of
More informationMERCER VALVE GENERAL INFORMATION THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY
MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY GENERAL INFORMATION MERCER VALVE THINK...MERCER FIRST Mercer Valve Company Mercer Valve Company, Inc. was founded by Wesley Taylor with his patented design for
More informationFuel Storage Dec 2016
Fuel Storage Dec 2016 1 Table of Contents SECTION I. ABOVEGROUND SMALL TANKS (1,100 GALLONS OR LESS)...3 Siting a new aboveground tank or tanks...3 Understanding fuel tank types....3 Where to find the
More informationSPCC Regulation Integrity and Leak Testing Methods
SPCC Regulation Integrity and Leak Testing Methods NISTM New England December 3 rd, 2015 Founded in 1988, Tanknology has grown to become one of the largest testing and inspection service companies in the
More informationChanges to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC
Changes to EPA s AST & UST Rules Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith Consulting Group, LLC 111 North Calhoun Street, Tallahassee, FL 32301 marshall@mott-smithconsulting.com
More informationNISTM 2015 New England UST and Shop-Fab Storage Tank Conference
NISTM 2015 New England UST and Shop-Fab Storage Tank Conference Presenter: Greg Young Vaporless Manufacturing, Inc. 928-775-5191 gyoung@vaporless.com Gregory Young 06/08/2014 Quality Petroleum Equipment
More informationProvide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.
UNDERGROUND STORAGE TANK SYSTEM INSTALLATION/UPGRADE SUPPLEMENT For use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: California Fire (CFC); Chapter 6.7, Health
More informationDate. Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4
Date Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4 To the Attention of the Director: Re: Insert Company Name Request for Variance
More informationRecommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities
PEI/RP1200-17 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities Inside Front Cover This page is intentionally
More informationMark S. Morgan, Regulatory Counsel
SUBJECT: ISSUE: PMAA CONTACT: EPA UST Regulations Final UST Rules Mark S. Morgan, Regulatory Counsel mmorgan@pmaa.org DATE: November 16, 2015 U.S. EPA FINAL UNDERGROUND STORAGE TANK REQUIREMENTS: I. BACKGROUND
More informationProduct overview. Technical data
VALVES & CONTROLS ANDERSON GREENWOOD BLANKETING SYSTEMS The Complete Blanketing and Safety Valve System! Product overview Pad Valves Anderson Greenwood is a world leader in tank protection and blanketing.
More informationEPA UST Regulations Update May 22, 2018
EPA UST Regulations Update May 22, 2018 Founded in 1988, Tanknology has grown to become one of the largest testing and inspection service companies in the world. Our fleet of 150 vehicles provides service
More information6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section
6. Tanks - Leak Detection NCDENR Division of Waste Management Underground Storage Tank Section Why conduct Leak Detection? Required for regulated systems: EXCEPTIONS: Temporarily closed tanks Emergency
More informationSECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)
SECTION 02554 - FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS) 1.1 SUMMARY A. Storage tanks, fuel oil, tank accessories, piping, valves, and specialties for fuel-oil distribution inside and
More informationSPCC Marina Inspection Update Oklahoma Marina Association Inspector Tom McKay
SPCC Marina Inspection Update - 2018 Oklahoma Marina Association Inspector Tom McKay Recent Compliance Assistance Documents 40 CFR 112 Final & Most Recent Regulation (7/1/15) Latest SPCC Inspection Checklists
More informationNYSDEC PBS REGULATIONS Heating Oil Tanks
1 NYSDEC PBS REGULATIONS Heating Oil Tanks Central Office/Region 2 Division of Environmental Remediation Bulk Storage Compliance Program NISTM 2017 New York Storage Tank Conference Saint Francis College,
More informationEarthsafe Systems, Inc. Page 1
ESS.WP.531. YQA Fuel Transfer Your Questions Answered (47) Fuel Transfer Systems earth safe Fuel Systems for Critical Power. 5.1 What types of pumps are used for fuel transfer? Fuel transfer pumps are
More informationHEAD VALVE. Model No.: NF 40/600V, NF 40/360V DESCRIPTION
HEAD VALVE Model No.: NF 40/600V, NF 40/360V DESCRIPTION NAFFCO 40/600 & NAFFCO 40/360 valve is a quick opening differential valve, especially designed for gaseous extinguishing agents in modular/centralized
More informationAVIATION FUELING CONTROL VALVES
c o n t r o l v a l v e s. c o m AVIATION FUELING CONTROL VALVES Quality products backed by the industry s leading warranty. For over 60 years, OCV has been a trusted name in the military and commercial
More informationTank Filling Systems. for Petroleum Products
Tank Filling Systems for Petroleum Products Tank Filling Systems for Petroleum Products page 2 What Is It Used For? Generally used with aboveground storage tanks, although some underground uses as well.
More informationState of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B
State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B Standing Loss Control Vapor Recovery System for New Installations of Aboveground Storage Tanks WHEREAS, the California Air Resources Board
More informationBiogas safety control equipment
Biogas safety control equipment As environmental concerns and energy efficiency are increasing, efficient economical and safe gas control systems become an increasingly important part of operating the
More informationSteel Tank Maintenance. Fluid Fertilizer Foundation December 4, 2012
Steel Tank Maintenance Fluid Fertilizer Foundation December 4, 2012 Tank Failure History Storage tank failure is as old as storage tank usage On January 15, 1919 a U.S. Industrial Alcohol Company s tank
More information1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions
1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions The 1618 Mechanical Gauge is designed to be used to measure liquid level in an aboveground storage tank. The gauge mounts to
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationNorth Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section
North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section To discover a release before a major contamination incident occurs Required
More informationThis handbook is provided as a general guide. https://floridadep.gov/waste/permitting-compliance- assistance/content/storage-tank-compliance
This handbook is provided as a general guide. For specific regulatory requirements refer to the underground and aboveground storage tank systems rules (Chapters 62-761 and 62-762, Florida Administrative
More informationADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for
ADDENDUM #1 The Plymouth Airport Commission is committed to fulfilling the New Fuel Farm Facility project within the scope of the permit, not exceeding our funding and to satisfy the time constraint associated
More informationCONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR
Environmental Health - UST Program CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR As part of our inter-local contract with the Nevada Division of Environmental
More information(3) (4) (6) (5) (10) (9) (8) (7)
3. Fuel System A: GENERAL The fuel pressurized by the fuel tank inside pump is delivered to each fuel injector by way of the fuel pipe and fuel filter. Fuel injection pressure is regulated to an optimum
More informationMOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
CHAPTER 22 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES SECTION 2201 GENERAL 2201.1 Scope. Automotive motor fuel-dispensing facilities, marine motor fuel-dispensing facilities, fleet vehicle motor
More informationFrequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania
Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania NISTM 6 th Annual Pennsylvania Storage Tank Conference April 9, 2015 Presented by: Randy Martin Solid Waste Program
More informationInspector's Initials: Tank Owner or Agent Signature: Title: Date:
STATE OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF UNDERGROUND STORAGE TANKS 4 TH Floor, L & C Tower 401 Church Street Nashville, TN 37243-1541 UST OPERATIONS INSPECTION Mo /Day
More informationSECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS
SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationFarm & Residential Tanks Angle skids
Farm & Residential Tanks Angle skids Multi-purpose, convenient, and economical fuel storage Each tank tested to ensure quality Engineered for strength and dependability Made with U.S. steel Tank listed
More informationCompliance Strategies and Benefits
Compliance Strategies and Benefits NISTM St. Louis Conference October 17, 2012 Brad Walls Director, Central Division Welcome Agenda Introduction Proposed Revisions to Federal Regulations Best Practices
More informationMOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
CHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES SECTION 2301 GENERAL 2301.1 Scope. Automotive motor fuel-dispensing facilities, marine motor fuel-dispensing facilities, fleet vehicle motor
More information2016 PRICE LIST TOTAL SYSTEM SOLUTIONS
2016 PRICE LIST TOTAL SYSTEM SOLUTIONS Effective February 1, 2016 Submersible Pumping Systems 1 Submersible Turbine Pumps 1 Variable Speed Submersible Turbine Pumps 1 Intelligent Submersible Turbine Pumps
More informationANDERSON GREENWOOD. Flow Control. Anderson Greenwood Tank and Equipment Blanketing Systems. Pad Valves. De-Pad Valves. Total Flow Control Solutions
ANDERSON GREENWOOD The Complete Blanketing and Safety Valve System! Anderson Greenwood is truly the world leader in tank protection and blanketing. Anderson Greenwood has the experience and products to
More informationUnderstanding the Inspection Process for Owners and Operators
Underground Storage Tanks (UST s) Metal Integrity and Lining Inspections Understanding the Inspection Process for Owners and Operators Presented By: Robert L. McChan II General Manager/Senior Project Manager/Steel
More informationMaxon Shut-Off and Vent Valves General Purpose
Maxon Shut-Off and Vent Valves General Purpose Bulletin 60 " Series 808 position "TO" 2" Series 00-CP position L with stainless steel body " Series STO-ACP position R Electrically actuated valves shut
More informationMERCER VALVE GENERAL INFORMATION
THINK...MERCER FIRST MERCER VALVE GENERAL INFORMATION Mercer Valve Company 1980s Mercer valve was founded by Wesley Taylor with his Auto Seat Technology patent for pressure relief valves. Mercer s first
More informationMAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.
MAKING MODERN LIVING POSSIBLE Solenoid valves EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical
More informationNYS DEPARTMENT OF ENVIRONMENTAL CONSERVATION CLASS C OPERATOR TRAINING
NYS DEPARTMENT OF ENVIRONMENTAL CONSERVATION CLASS C OPERATOR TRAINING Presented by: The New York State Association of Service Stations and Repair Shops AT LEAST ONE TRAINED C OPERATOR MUST BE ON DUTY
More informationInstructions for Installation, Operation Care and Maintenance
Model A Dry Pipe Valve Bulletin 353 Rev.K Bulletin 353 Rev.K Instructions for Installation, Operation Care and Maintenance 2 1 2 (65mm) Valve With Model A Trim Listed by Underwriters Laboratories, Inc.
More informationCounty of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION
April Meneghetti, REHS Environmental Health Divison Manager County of Yolo DEPARTMENT OF COMMUNITY SERVICES Environmental Health Division 292 West Beamer St., Woodland, CA 95695 PHONE - (530) 666-8646
More informationOverview of an Underground Storage Tank Inspection
Overview of an Underground Storage Tank Inspection PURPOSE OF INSPECTION Protect drinking water, lakes, streams, etc. Education. Protect property value. TECHNICAL ASSISTANCE INSPECTIONS Technical Assistance
More informationRegulatory Changes: Chapter 245. AST s
Regulatory Changes: Chapter 245 AST s 245.1 Definitions NEW Aboveground storage tank One or a combination of stationary tanks with a capacity in excess of 250 gallons, including the underground pipes and
More informationFuel Management Systems
UTILITIES MFG CORPORATION Fuel Management Systems Inside: Fuel Transfer Pump Sets Fuel Filtration Sets Pump and Day Tank Sets Fuel Oil Handling Systems Fuel Oil Additives and Treatments Fuel Oil Specialties
More informationHow to Comply with Florida DEP AST Rules and Avoid Petroleum Discharges to the Environment
How to Comply with Florida DEP AST Rules and Avoid Petroleum Discharges to the Environment Aboveground Storage Tank Systems Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith
More informationNational Board Update
National Board Update Presentation to the Valve Repair Council June 2, 2016 Prepared by: Joseph F. Ball, P.E. National Board Update National Board activities Who we are and what we do National Board Inspection
More informationTodd Evacuation Caddy
Todd Evacuation Caddy WARNINGS AND INSTRUCTIONS FOR GASOLINE USE PLEASE READ ALL OF THIS INFORMATION DANGER EXTREMELY FLAMMABLE VAPORS CAN EXPLODE HARMFUL OR FATAL IF SWALLOWED! Vapors can cause flash
More informationOKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS
OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS PO BOX 52000 OKC, OK 73152-2000 www.occeweb.com Created on 10/1/2008
More informationPackaged Design Day Tank Systems
Fuel Supply Systems Packaged Design Day Tank Systems for diesel/fuel oil application providing a reliable fuel source for diesel and turbine engine driven equipment and oil fired boilers model & accessory
More information