Fuel Dispensing Stations Wash areas Car parks Roads Industrial Activities

Size: px
Start display at page:

Download "Fuel Dispensing Stations Wash areas Car parks Roads Industrial Activities"

Transcription

1 RAINWAteR treatment FRANCeAUX oil separators Fuel Dispensing Stations Wash areas Car parks Roads Industrial Activities

2 WHY CHOOSING? 35 YEARS OF RESEARCH AND DEVELOPMENT! By choosing, you will choose a strong business leader with 35 years of experience and an international reputation. Our offi ce, impregnated with a strong spirit of innovation, is constantly at the forefront of new techniques and technologies. The strength of our research and development allows us to continually evolve existing products launched on the market regularly which have reliable and sustainable solutions which contribute to improve the environment and its patented processes. LARGE STOCKS AVAILABLE > STARTING IN 72H! MONTDIDIER LE HAM BOURG-DE-PÉAGE BORDEAUX 4 INDUSTRIAL SITES FOR GREATER RESPONSIVENESS! Our French production is spread over four sites to ensure manufacturing closest to you, and delivery within 5 days for most of our reference standards. Upon receipt of order, your separator leaves our production site within 72 hours. 2 This document does not form part of any contract. The data is provided as an indication and may be changed without notice.

3 Summary Technical Sheets REF. REF. FRANCEAUX PAGE PRESENTATION... 2 SELECTION GUIDE... 4 OIL SEPARATORS PAINteD steel NF 5 MG/L V100 SILT STORAGE MANHOLE MACKNF NF 5 MG /L V100 SILT STORAGE WITHOUT PROTECTION MACKNF NF 5 MG/L V100 SILT STORAGE BYPASS MANHOLE PAINTED STEEL PASSNF NF 5 MG/L V100 SILT STORAGE BYPASS WITHOUT PROTECTION PAINTED STEEL PASSNF CE 5 MG/L V100 SILT STORAGE MANHOLE MACK CE 5 MG/L V100 SILT STORAGE WITHOUT PROTECTION MACK-AT CE 5 MG/L V300 SILT STORAGE MANHOLE LAVK CE 5 MG/L V300 SILT STORAGE WITHOUT PROTECTION LAVK-AT CE 5 MG/L V100 SILT STORAGE BYPASS MANHOLE PASSK CE 5 MG/L V100 SILT STORAGE BYPASS WITHOUT PROTECTION PASK-AT CE 5 MG/L V100 SILT STORAGE WITH A COMPARTMENT FIT FOR A PUMPING STATION FOSKAT... 21/22 OIL SEPARATORS PoLYetHYLeNe CE 5 MG/L V100 SILT STORAGE FROM 1.5 TO 15 L/S NPBCKA/NPBCK CE 5 MG/L V100 SILT STORAGE FROM 20 TO 30 L/S NPBCKA/NPBCK CE 5 MG/L V100 SILT STORAGE AND BYPASS FROM 3 TO 15 L/S DOKAC/DOK CE 5 MG/L V100 SILT STORAGE AND BYPASS FROM 20 TO 30 L/S DOKAC/DOK CE 5 MG/L V200 SILT STORAGE OIL SEPARATORS MADe CUstoM steel AND GRP CE 5 MG/L WITH SILT STORAGE / STEEL / FLOW > 50 L/S IA CE 5 MG/L WITH SILT STORAGE / BYPASS / STEEL / FLOW > 50 L/S IACD CE 5 MG/L WITH SILT STORAGE / GRP / FLOW > 50 L/S IAPRV CE 5 MG/L WITH SILT STORAGE / GRP / BYPASS / FLOW > 50 L/S IADPRV LEVEL ALARMS SELECTION TABLE OIL LEVEL ALARM POWERED BY A SOLAR PANEL ALARME OIL LEVEL ALARM ALARME SLUDGE LEVEL ALARM ALARM ALARM DETECTING OVERFLOW ALARM BOX OR JUNCTION SLEEVE, CABLE FOR OIL ALARM ATEX BMJ ACCESSORIES ACCESSORIES FOR STEEL OIL SEPARATORS RH ADJUSTABLE EXTENSION SHAFT FOR POLYETHYLENE OIL SEPARATORS RHPEH ANCHORING STRAPS FOR OIL SEPARATORS CEINT SLUDGE EXTRACTION DEVICE KIT-ASPI OIL BELT TRANSFER CAPT EXTERNAL CATHODIC PROTECTION ANODE GRAVEL FILTER DRAIN WITH FIREWALL DEVICE AVCF... 44/45 INSTALLATION INSTRUCTIONS PARALLELIPEDIC OIL SEPARATOR WITH MANHOLE... P STEEL PARALLELIPEDIC OIL SEPARATOR WITH STEEL ADJUSTABLE EXTENSION SHAFT... P OIL SEPARATOR OF THE POLYETHYLENE RANGE... P POLYETHYLENE OIL SEPARATOR TO BE BURIED... P POLYETHYLENE OIL SEPARATOR ON GROUND WITH A WATER TABLE... P /51 ANH22/14320 AND ANH22/15200 ALARMS FOR STEEL OIL SEPARATORS... P083...APHA...52 ANH22/14320 AND ANH22/15200 ALARMS FOR POLYETHYLENE OIL SEPARATORS... P084...APHP GENERAL MAINTENANCE INSTRUCTIONS POLYETHYLENE OIL SEPARATOR < 30 L/S... E /58 1

4 A MULTI-MATERIAL PRODUCTION Simop offers a complete range of oil separators in steel, polyester and polyethylene. Their production uses different technologies to meet your needs. GUARANTEE 20 YEARS STABLE MATERIAL Polyethylene Simop has 35 years of experience in the manufacture of rotational molding. Our industrial allows us to manufacture the larger monobloc parts in Europe (35 m3). This ensures easy implementation and maintenance, perfect sealing of our devices and has the advantage of being recyclable. Rotomolding Rotomolded part GUARANTEE 20 YEARS AGAINST CORROSION Polyester Our method, based on the principle of fi lament winding, fully automated, provides continuity of production with a perfect control of the fi nished product and optimization of mechanical strength. Filament winding Separator Steel Production is subject to quality control and strict traceability from the matter to the finished product to shipping : all production operations are traced. Simop has a fully automated grit blasting unit and a paint booth integrated to the production chain which ensure greater consistency in the quality of its products and a coating in accordance with the requirements of standard EN Grit blasting unit Paint booth REMINDER: oil separators must bear the CE marking in accordance with the Ministerial Decree dated January 27th 2006 and Annex ZA of the standard NF EN Unless special dispensation from the local authorities, this order also makes mandatory oil level alarm as additional equipment. The Environmental Code prohibits the discharge of lubricants, new or spent oils into surface waters, groundwater or in the street. Service stations, repair shops, washing areas, car parks must be equipped with an oil separator preceded by a débourbeur. The sludge, often directly integrated to the separator, holds heavy materials from the raw water, then the separator trap the suspended oils from the collected runoff water. 2

5 A COMPANY AT THE CUTTING EDGE OF TECHNOLOGY The widest range on the market Based on our 35 years of technical and industrial experience, we offer polyethylene, polyester and steel oil separators constituting the multi-line materials the widest on the market. Cell coalescence device Our oil separators are equipped with polypropylene cells (stable material) which ensure the separation between oils and runoff water thanks to the coalescence and a very high specifi c surface. These cells, movable in relation to each other (type fl uidized bed) avoid clogging. In addition, maintenance is very simple (suction truck, easy replacement, shock resistance). A network of efficient maintenance Having our own maintenance network, we can ensure the implementation and maintenance of your equipment throughout France. A test base validated CSTB Prior to be launched on the market, All devices are tested on our test base. This base was conducted in accordance with standard NF EN and approved by the CSTB in the context of an application for admission to the NF marking (French Standard). Finally, our polyethylene and GRP devices are subject to quality control and their traceability are guaranteed for 20 years against corrosion. CSTB Validated 3

6 What is the risk of oil contaminating the drainage from the site? CHOOSE THE SEPARATOR CLASS - CLASS 1: 5 MG/L REQUIRED FOR DISCHARGES TO SURFACE WATER DRAINS AND THE WATER ENVIRONMENT. - CLASS 2: 100 MG/L REQUIRED FOR DISCHARGES TO THE PUBLIC SEWER. CHOOSE THE SILT STORAGE VOLUME IT IS DETERMINED ACCORDING TO THE AMOUNT OF SLUDGE AND USE OF THE SEPARATOR. Low risk of contamination or episodic risks of small spills (roads, car parks,...) Bypass oil separator required Frequent contamination (auto parts stores, petrol stations, oil storage areas, car wash areas, industrial sites,...) Oil separator without by-pass required Sludge quantity WEAK examples of use Wastewater containing a small amount of sludge defi ned All areas of collecting rainwater where a small amount of sediment is due to traffi c or similar, for example catchments in the parks of petroleum storage and covered fi lling stations. Filling stations, manual car wash areas, parts wash areas buses wash sites Waste water of the garages, car parks Power plants, tooling factories wash areas for construction vehicles, construction machines, agricultural machinery wash areas for trucks automatic car wash areas, for example rollers, corridors Mini silt storage volume V100 Choose the separator class Choose the separator class MEDIUM V200 Calculation of the fl ow rate of rain water Calculation of the fl ow rate of waste water Calculation of the fl ow rate of rain water HIGH V300 Calculation of the nominal size Calculation of the nominal size CCTP type for oil separators 5mg/l Choose the silt storage volume Choose the silt storage volume >Storm water may be strictly discharged strictly into the environment. > The waste water must be strictly rejected by the public sewer wastewater. > Mixtures stormwater / wastewater must be discharged into the public sewer wastewater. In principle, we consider the density is 0.85 and there is not detergent. If there is a detergent presence or if the density is not 0,85, please consult us. > STEEL The range of steel oil separators is prescribed with text and according to the standards below: Standards: equipment designed in accordance with standard EN858 standard and XP P /CN-1. CE marking in accordance with EN The separators are available with the following options: overfl ow alarms, sludge and oil alarms, oil belt transfer, sludge suction, external anodes and extension shafts. CCTP type : oil separators with sludge, brand or similar, blasted and painted steel type... (name of the separator), rejection 5 mg/l at any point in accordance with standard EN858-1, designed according to the standard XP P /CN and CE marked, treated fl ow rate...l / s. Audible and visual SI- MOP alarm of an ATEX standard proposed and provided by the manufacturer. All separators may be provided either with total accessibility with extension shafts 125 or 250 KN, either with manhole(s) without lid. > POLYETHYLENE The range of HDPE oil separators, CE labeled, is prescribed with text and according to the standards below : Standards : Manufactured in accordance with CE standard EN The standard is about two types of rejection classes - Class 1: rejection of 5mg/l and Class 2: rejection of 100 mg/l. The separators are available with the following options : overfl ow alarms, sludge and oil alarms, oil belt transfer, sludge suction and extension shafts. CCTP type: oil separator with sludge, brand or similar, high density polyethylene type... (name of the separator), rejection class:...mg/l at any point in accordance with standard EN 858-1, CE marked, treated fl ow rate...l/s. Audible and visual alarm of an ATEX standard proposed and provided by the manufacturer. All separators may be provided either with total accessibility with extension shafts 125 or 250 KN, either with manhole(s) without lid. 4

7 WASHING AREAS USE AND APPLICATION Separators with bypass device (bypass) not suitable for this type of use. covered washing area WASHING GUIDE Ø20 PIPE, LIGHT VEHICLE Taps Flow rate to be treated* NS** 1 1 l/s 1,5 l/s 2 2 l/s 3 l/s 3 2,7 l/s 3 l/s 4 3,2 l/s 6 l/s 5 3,4 l/s 6 l/s > 5 + 0,2 l/s and /tap Piping ø25, HEAVY TRUCKS Taps Flow rate to be treated * NS** 2 3,4 l/s 6 l/s 3 4,6 l/s 6 l/s 4 5,45 l/s 6 l/s 5 5,75 l/s 6 l/s > 5 + 0,3 l/s and /tap ROLLERS Washing Units Flow rate to be treated * NS** 1 2 l/s 3 l/s 2 4 l/s 6 l/s 3 6 l/s 6 l/s 4 8 l/s 8 l/s 5 10 l/s 10 l/s High Pressure Washing Units Flow rate to be treated * NS** 1 2 l/s 3 l/s 2 3 l/s 3 l/s 3 4 l/s 6 l/s 4 5 l/s 6 l/s 5 6 l/s 6 l/s not covered washing area 1 Search the nominal size (NS) in the table of a covered washing area. 2 - Search the nominal size in the table concerning non-covered car parks without bypass. 3 - NS to remember is the more important of the two. range meeting your needs without the possibility of a by-pass Silt storage Material Treatment Output Size Technical Sheet Page V100 Steel without bypass 5 mg/l from 1,5 to 50 l/s 4804 with manhole 15 V100 Steel without bypass 5 mg/l from 1,5 to 50 l/s 4805 with frame 16 V100 Steel without bypass 5 mg/l from 3 to 50 l/s 4816 with frame 21/22 V300 Steel without bypass 5 mg/l from 1,5 to 20 l/s 4808 with manhole 17 V300 Steel without bypass 5 mg/l from 1,5 to 20 l/s 4809 with frame 18 V100 PE without bypass 5 mg/l from 1,5 to 15 l/s V100 PE without bypass 5 mg/l from 20 to 30 l/s V200 PE without bypass 5 mg/l from 3 to 15 l/s *The flow rate to be treated is calculated according to the indications of the Order dated January 7th 2003 on classified installations under ** Example in the absence of detergent and for oils of a density of

8 CAR PARKS, ROADS AND INDUSTRIAL ACTIVITIES USE AND APPLICATION REGION 1 Rainfall in different regions REGION 2 RÉGION 3 Covered car parks WATER POLLUTION : The discharge of waste water must be removed by means of a tank (collector) with a separation device or any other system capable of retaining all fl ammable liquids that may be accidentally spread ; a manhole easily accessible, will be out in place before connecting to the network. The installation will be maintained in good operating condition and cleared of sludge and fl ammable liquids recovered as often as necessary. Sludges and liquids recovered shall not be thrown into the sewer but delivered to a specialized company that has authorized treatment facilities. with the possibility of a bypass or without the possibility of a bypass Surface area NS** m 2 3 l/s m 2 6 l/s m 2 15 l/s m 2 20 l/s m 2 25 l/s Non-covered car parks For surface areas up to m2, the calculation of the fl ow rate in liter/second is based on the region, on the surface area and on the runoff coeffi cient. The failure return period of the network is 10 years. For upper surface areas, contact us. With bypass possibility Treated fl ow Pluviometry rate = 20% 300 l/s/ha 400 l/s/ha 500 l/s/ha of the peak fl ow maxi surface area REGION 1 REGION 2 REGION 3 NS** 560 m m m 2 3 l/s 1110 m m m 2 6 l/s 1480 m m m 2 8 l/s 1850 m m m 2 10 l/s 2780 m m m 2 15 l/s 3700 m m m 2 20 l/s 4630 m m m 2 25 l/s 5555 m m m 2 30 l/s 6481 m m m 2 35 l/s 7407 m m m 2 40 l/s 9260 m m m 2 50 l/s Without possibility of bypass Pluviometry 300 l/s/ha 400 l/s/ha 500 l/s/ha maxi surface area REGION 1 REGION 2 REGION 3 NS** 110 m 2 80 m 2 70 m 2 3 l/s 220 m m m 2 6 l/s 300 m m m 2 8 l/s 370 m m m 2 10 l/s 560 m m m 2 15 l/s 740 m m m 2 20 l/s 925 m m m 2 25 l/s m m m 2 30 l/s m m m 2 35 l/s m m m 2 40 l/s m m m 2 50 l/s Roads Residential and rural areas, urban centers, landscape basin upstreams, retention basin downstreams (settling) retention basin upstreams (settling). Industrial Activities Careening, scrap yards, tire industries, waste reception centers, mechanical workshops, steel cutting workshops, power plants, tool factories, auto garages (sewage), ports, airports, cargo areas, processing of building materials (terracotta, stone,...). Separators with bypass are not suitable for this type of use. *The flow rate to be treated is calculated according to the indications of the the Order dated January 7th 2003 on classified installations under ** Example in the absence of detergent and for oils of a density of

9 CAR PARKS, ROADS AND INDUSTRIAL ACTIVITIES USE AND APPLICATION range meeting your needs without the possibility of a bypass Silt storage Material Treatment Output Size Technical Sheet Page V100 steel without bypass 5 mg/l from 1,5 to 50 l/s 4804 with manhole 15 V100 steel without bypass 5 mg/l from 1,5 to 50 l/s 4805 with frame 16 V100 steel without bypass 5 mg/l from 3 to 50 l/s 4816 with frame 21/22 V300 steel without bypass 5 mg/l from 1,5 to 20 l/s 4808 with manhole 17 V300 steel without bypass 5 mg/l from 1,5 to 20 l/s 4809 with frame 18 V100 PE without bypass 5 mg/l from 1,5 to 15 l/s V100 PE without bypass 5 mg/l from 20 to 30 l/s V200 PE without bypass 5 mg/l from 3 to 15 l/s range meeting your needs with the possibility of a bypass Silt storage Material Treatment Output Size Technical Sheet Page V100 steel bypass 5 mg/l from 3 to 50 l/s 4810 with manhole 19 V100 steel bypass 5 mg/l from 3 to 50 l/s 4811 with frame 20 V100 PE bypass 5 mg/l from 3 to 15 l/s V100 PE bypass 5 mg/l from 20 to 30 l/s

10 PETROL STATIONS USE AND APPLICATION SEPARATORS WITH BYPASS DEVICE ARE NOT SUITABLE FOR THIS TYPE OF USE. Covered car park Surface Flow rate to be treated* NS** 120 m 2 0,75 l/s 1,5 l/s 240 m 2 1,5 l/s 1,5 l/s 480 m 2 3 l/s 3 l/s 800 m 2 5 l/s 5 l/s Non-covered car park Surface Flow rate to be treated* NS** 120 m 2 1,5 l/s 1,5 l/s 240 m 2 3 l/s 3 l/s 480 m 2 6 l/s 6 l/s 800 m 2 10 l/s 10 l/s range meeting your needs without the possibility of a bypass Silt storage Material Treatment Output Size Technical Sheet Page V100 steel without bypass 5 mg/l from 1,5 to 50 l/s 4804 with manhole 15 V100 steel without bypass 5 mg/l from1,5 to 50 l/s 4805 with frame 16 V100 steel without bypass 5 mg/l from 3 to 50 l/s 4816 with manhole 21/22 V300 steel without by pass 5 mg/l from 1,5 to 20 l/s 4808 with frame 17 V300 steel without by pass 5 mg/l from 1,5 to 20 l/s 4809 with manhole 18 V100 PE without by pass 5 mg/l from 1,5 to 15 l/s V100 PE without by pass 5 mg/l from 20 to 30 l/s V200 PE without by pass 5 mg/l from 3 to 15 l/s * The flow rate to be treated is calculated according to the indications of the the Order dated January 7th 2003 on classified installations under ** Example in the absence of detergent and for oils of a density of

11 ACCESSORIES Alarms > Audible and visual sludge level alarm This device can detect if the deposit of sludge formed in the sludge compartment has reached the maximum allowable level without affecting the operation of the unit. Sensor embedded in the device detects the sludge blanket and triggers the alarm. > Audible and visual oil level alarm This device can detect the level of oil in the separator before sealing the system. The sensor inside the separator detects the oil / water interface and thus allows the Supervisor to monitor the thickness of the oil layer stored. When the maximum retention level is reached, the alarm sounds. Depending on the selected alarm, please fi nd the reference to order. > Audible and visual oil level alarm with solar panel The system control and alarm with solar panel supply is designed for monitoring the thickness of the oil layer or stored sludge level in a separator, when there is no scope of electric line. Extension shafts (optional) > Device with full accessibility Extension shafts are available to adjust the frames to the height of the fi nished fl oor and to put in place the devices with a frost protection : the standard extension shafts have heights of 200, 350, 500, 650 and 800 mm. The shims are used to adjust the device s height up to 150 mm for each preset height and catch a slope laterally and longitudinally of the fi nished fl oor. Our separators allow the installation of cast iron covers 125 or 250 KN. > Device with manhole Concrete extension shafts, commercially available, are adaptable to our manholes in accordance with EN476. The Ministerial Decree of 27 January 2006 mandates an alarm level as additional equipment. offers single level alarms and alarms powered by solar panels. PE extension shafts RH6069 Steel extension shaft Ref. : ANH22/ Ref. FRANCEAUX : ALARM-HYDRO-SOL-ATEX Audible and visual oil level alarm IP65 powered by solar panel Ref. : ANH22/ Ref. FRANCEAUX : ALARM-HY-SOL-GSM-ATEX Audible and visual oil level alarm IP65 + GSM powered by solar panel Ref. : ANH22/ Réf. FRANCEAUX : ALARM-HYDRO-ATEX Audible and visual oil level alarm IP65. Ref. : ANH22/ Ref. FRANCEAUX : ALARM-GSM-ATEX Audible and visual oil level alarm IP65 + GSM Refer to datasheets 4981 and 4982 pages 33 and 34. Blanking plate TR4 Refer to data sheets 4984 and 6069 pages 38 and 39. 9

12 The Services Thanks to their integrated modems, alarms with GSM are the ideal solution for separators of a remote monitoring center (car parks, tunnel, bridge, airport runways, highways,...). If an alarm is triggered, an SMS is sent via modem to authorized persons. Our assistance takes over and sends an on-site technician which will drain the unit. The relay can receive up to 3 different sensors among the three existing types : layer thickness sensor ; overfl ow sensor ; sludge level sensor. For the alarm powered by a solar panel, it is possible to double the number of sensors. 2 Alert 1 Detection 4 Intervention 3 Treating Information 10

13 OIL SEPARATOR NF 5 MG / L SILT STORAGE V100 AND MANHOLE COVERS PAINTED STEEL MACKNF 4730 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V100 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF P /CN and are NF marked. Installation Respect the recommendations of the P039 installation instructions on page 46. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection A circular cast iron cover must be provided. Its size (125 KN, 250 KN or 400 KN) will depend on the conditions on site (moving load). Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D E F G H Silt storage Volume Nb manholes SH4730/01/00 1, SH4730/03/ SH4730/06/ Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole 11

14 OIL SEPARATOR NF 5 MG / L WITH SILT STORAGE V100 WITHOUT PROTECTION PAINTED STEEL MACKNF 4731 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V100 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF P /CN and are NF marked. Installation Respect the recommendations of the P040 installation instructions on page 47. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection It is essential to choose a type of protection with rectangular frames 3 KN, 125 KN and 250 KN. See data sheet 4984 for the steel extension shafts with cast iron covers 125 KN or 250 KN. Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarms The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D1 D2 E F G H Silt storage Volume Stainless steel Ref. 3 kn Stainless steel Qty Cast iron Ref. 3 kn SH4731/01/RP1L 1, TXPL 1 TFPL 1 SH4731/03/RG1L TXGL 1 TFGL 1 SH4731/06/RP2T TXPT 2 TFPT 2 Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OT-80 Extraction device, opening manhole Cast iron Qty 12

15 OIL SEPARATOR NF 5MG / L WITH SILT STORAGE V100 BYPASS MANHOLE COVERS PAINTED STEEL PASSNF 4732 C1=C-121 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. A bypass located at the inlet box is used to regulate the fl ow (20% of treatment permissible fl ow) Zone V100 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF P /CN and are NF marked. Installation Respect the recommendations of the P039 installation instructions on page 46. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Protection A circular cast iron cover must be provided. Its size (125 KN, 250 KN or 400 KN) will depend on the conditions on site (moving load). Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D E F G H Silt storage Volume Nb Silt storage SH4732/03/ SH4732/06/ Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole 13

16 OIL SEPARATOR NF 5 MG / L WITH SILT STORAGE V100 BYPASS WITHOUT PROTECTION PAINTED STEEL PASSNF 4733 C1=C-121 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. A bypass located at the inlet box is used to regulate the fl ow (20% of treatment permissible fl ow) Zone V100 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF P /CN and are NF marked. Installation Respect the recommendations of the P040 installation instructions on page 47. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Protection It is essential to choose a type of protection with rectangular frames 3 KN, 125 KN and 250 KN. See data sheet 4984 for the steel extension shafts with cast iron covers 125 KN or 250 KN. Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D1 D2 E F G H Vol. silt storage Stainless steel Ref. 3 kn Stainless steel Qty Cast iron Ref. 3 kn SH4731/03/RG1L TXGL 1 TFGL 1 SH4731/06/RP2T TXPT 2 TFPT 2 Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole Cast iron Qty 14

17 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE V100 AND MANHOLE COVERS PAINTED STEEL MACK 4804 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V100 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF EN858-1 and NF EN858-2 and are CE marked. Installation Respect the recommendations of the P039 installation instructions on page 46. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection A circular cast iron cover must be provided. Its size (125 KN, 250 KN or 400 KN) will depend on the conditions on site (moving load). Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D E F G H Silt storage Volume Nb. manholes SH4804/08/ SH4804/10/ SH4804/15/ SH4804/20/ SH4804/25/ SH4804/30/ SH4804/35/ SH4804/40/ SH4804/50/ Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole 15

18 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE V100 WITHOUT PROTECTION PAINTED STEEL MACK-AT 4805 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V100 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF EN858-1 and NF EN858-2 and are CE marked. Installation Respect the recommendations of the P040 installation instructions on page 47. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection It is essential to choose a type of protection with rectangular frames 3 KN, 125 KN and 250 KN. See data sheet 4984 for the steel extension shafts with cast iron covers 125 KN or 250 KN. Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D1 D2 E F G H Silt storage Volume Stainless steel Ref. 3 kn Stainless steel Qty Cast iron Ref. 3 kn SH4805/08/RG2T TXGT 2 TFGT 2 SH4805/10/RG2T TXGT 2 TFGT 2 SH4805/15/RG3T TXGT 3 TFGT 3 SH4805/20/RG4T TXGT 4 TFGT 4 SH4805/25/RG4T TXGT 4 TFGT 4 SH4805/30/RG4T TXGT 4 TFGT 4 SH4805/35/RG4T TXGT 4 TFGT 4 SH4805/40/RG4T TXGT 4 TFGT 4 SH4805/50/RG5T TXGT 5 TFGT 5 Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole Cast iron Qty 16

19 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE V300 AND MANHOLE COVERS PAINTED STEEL LAVK 4808 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V300 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF EN858-1 and NF EN858-2 and are CE marked. Installation Respect the recommendations of the P039 installation instructions on page 46. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection A circular cast iron cover must be provided. Its size (125 KN, 250 KN or 400 KN) will depend on the conditions on site (moving load). Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D E F G H Silt storage Volume Nb. manholes SH4808/01/00 1, SH4808/03/ SH4808/06/ SH4808/08/ SH4808/10/ SH4808/15/ SH4808/20/ Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole 17

20 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE V300 WITHOUT PROTECTION PAINTED STEEL LAVK-AT 4809 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V300 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF EN858-1 and NF EN858-2 and are CE marked. Installation Respect the recommendations of the P040 installation instructions on page 47. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection It is essential to choose a type of protection with rectangular frames 3 KN, 125 KN and 250 KN. See data sheet 4984 for the steel extension shafts with cast iron covers 125 KN or 250 KN. Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D1 D2 E F G H Silt storage Volume Stainless steel Ref. 3 kn Stainless steel Qty Cast iron Ref. 3 kn SH4809/01/RP2T TXGL 1 TFPT 1 SH4809/03/RG2T TXPT 2 TFGT 2 SH4809/06/RG4T TXGT 2 TFGT 2 SH4809/08/RG4T TXGT 2 TFGT 2 SH4809/10/RG4T TXGT 2 TFGT 2 SH4809/15/RG4T TXGT 3 TFGT 3 SH4809/20/RG5T TXGT 4 TFGT 4 Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole Cast iron Qty 18

21 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE V100 BYPASS MANHOLE COVERS PAINTED STEEL PASSK 4810 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V100 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF EN858-1 and NF EN858-2 and are CE marked. Installation Respect the recommendations of the P039 installation instructions on page 46. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection A circular cast iron cover must be provided. Its size (125 KN, 250 KN or 400 KN) will depend on the conditions on site (moving load). Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D E F G H Silt storage Volume Nb. manholes SH4810/08/ SH4810/10/ SH4810/15/ SH4810/20/ SH4810/25/ SH4810/30/ SH4810/35/ SH4810/40/ SH4810/50/ Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole 19

22 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE V100 BYPASS WITHOUT PROTECTION PAINTED STEEL PASK-AT 4811 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Surface car parks and roads may be equipped with an oil separator with bypass and upstream silt storage. Installation Respect the recommendations of the P040 installation instructions on page 47. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection It is essential to choose a type of protection with rectangular frames 3 KN, 125 KN and 250 KN. See data sheet 4984 for the steel extension shafts with cast iron covers 125 KN or 250 KN. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V100 sludge integrated into the device retains heavy matter. Our devices are in accordance with NF EN858-1 and NF EN858-2 and are CE marked. Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D1 D2 E F G H Silt storage Volume Stainless steel Ref. 3 kn Stainless steel Qty Cast iron Ref. 3 kn SH4811/08/RG2T TXGT 2 TFGT 2 SH4811/10/RG2T TXGT 2 TFGT 2 SH4811/15/RG3T TXGT 3 TFGT 3 SH4811/20/RG4T TXGT 4 TFGT 4 SH4811/25/RG4T TXGT 4 TFGT 4 SH4811/30/RG4T TXGT 4 TFGT 4 SH4811/35/RG4T TXGT 4 TFGT 4 SH4811/40/RG4T TXGT 4 TFGT 4 SH4811/50/RG5T TXGT 5 TFGT 5 Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole Cast iron Qty 20

23 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE V100 WITH A COMPARTMENT FIT FOR A PUMPING STATION (NOT INCLUDED) PAINTED STEEL FOSKAT 4816 C1=C-132 mm EN858-1 Use The Environmental Code prohibits the discharge of lubricants, new or spent oils, into surface and/or underground water channels. Petrol stations, car parks, repair shops, washing areas, must be equipped with an oil separator and upstream silt storage. Installation Respect the recommendations of the P040 installation instructions on page 47. The device will be buried. In cases of extra load or a backfi ll of over 50cm, a concrete slab must be cast in order to withstand the strains imposed. Attention to special installation conditions hydromorphic fi eld. Important : pull on the fl oat immediately when refi lling the separator with clean water up to the outlet level, then check that it fl oats correctly on the upper level of the apparatus. Refer to the guidelines of standard NF P for installation, handling and maintenance information, available from AFNOR. Protection It is essential to choose a type of protection with rectangular frames 3 KN, 125 KN and 250 KN. See data sheet 4984 for the steel extension shafts with cast iron covers 125 KN or 250 KN. Technical Defi nition This range of oil separators 5 mg/l is designed to trap hydrocarbons in suspension in the collected water. Zone V100 sludge integrated into the device retains heavy matter. A pumping station is integrated in a separate compartment (contact our research department to choose the pump according to the fl ow and the height to be lift up. Our devices are in accordance with NF EN858-1 and NF EN858-2 and are CE marked. Maintenance The coating of the device must be checked periodically, and if necessary, repaired. The oil level alarm is set off when the separated light liquid/water interface level reaches the maximum recommended oil storage volume. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P Alarm The oil level alarm is a mandatory element of additional equipement, except if a special derogation has been obtained from local authorities. References : ANH22/14320 with power supply ; ANH22/14506 with solar panel. Reference Size A B C D1 D2 E F F1 G H SH4816/03/RP2T SH4816/06/RG3T SH4816/10/RG4T SH4816/15/RG4T Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) OD4/2102/OTH-80 Extraction device, opening manhole 21

24 PUMP SELECTION GUIDE FOR OIL SEPARATOR WITH PUMPING STATION 1 OR 2 PUMP ON TRIPOD 4816 Help me choose Choosing devices with 2 pumps allow to increase the life of the pumps. Indeed they operate alternately with a control unit outside the pumping station. Pump determination 1.5 l / s 10 PP4816/01/01-4 (1 pompes) pump) 9 PP4816/02/01-4 (2 pompes) pumps) 8 PP4816/01/01-3 (1 pompes) pump) 7 PP4816/02/01-3 (2 pompes) pumps) 6 PP4816/01/01-2 (1 pompe) pump) 5 PP4816/02/01-2 (2 pompes) pumps) PP4816/01/01-1 (1 pompe) pump) 1 PP4816/02/01-1 (2 pompes) pumps) DISCHARGE LENGTH PVC PRESSURE 50 MM HEIGHT IN METERS TO BE LIFT UP (GH) Pump determination 3 l/s HEIGHT IN METERS ) TO BE LIFT UP (GH) Pump determination 6 l/s HEIGHT IN METERS TO BE LIFT UP (GH) PP4816/01/03-4 (1 pompes) pump) PP4816/02/03-4 (2 pompes) pumps) PP4816/01/03-3 (1 pompes) pump) PP4816/02/03-3 (2 pompes) pumps) PP4816/01/03-2 (1 pompe) pump) PP4816/02/03-2 (2 pompes) pumps) PP4816/01/03-1 (1 pompe) pump) PP4816/02/03-1 (2 pompes) pumps) DISCHARGE LENGTH PVC PRESSURE Ø 65 MM PP4816/01/06-3 (1 pompes) pump) PP4816/02/06-3 (2 pompes) pumps) PP4816/01/06-2 (1 pompe) pump) PP4816/02/06-2 (2 pompes) pumps) PP4816/01/06-1 (1 pompe) pump) PP4816/02/06-1 (2 pompes) pumps) DISCHARGE LENGTH PVC PRESSURE 80 MM 22

25 OIL SEPARATORS 5 MG/L WITH SILT STORAGE V100 IN POLYETHYLENE NPBCKA/NPBCK 6645 Technical defi nition An oil separator is a device designed to trap and store free hydrocarbons from runoff water. The silt storage unit traps suspended solids (sand, gravel ). These oil separators without by-pass and equipped with a silt storage are designed to treat water from covered car parks, petrol stations, garages. For washing areas a complementary silt storage V200 must be provided to obtain a V300 volume. Reminder :The oil level alarm is mandatory as additional piece of equipment. Operation The operation of the oil separator is based on the separation by density difference of insoluble pollutants contained in runoff water. The silt storage compartment settles and traps suspended solids (>200µm). The coalescence system, with its large surface area, enables the concentration of free hydrocarbons which are bumping each other. Hydrocarbons rise then to the surface. The sealing system (shutter) prevents from any risk of hydrocarbon release. DEVICE WITH PE MANHOLES ØD C ØD B EN858-1 Advantages Patented design in accordance with standards : EN and EN A 20 year guarantee tank against corrosion Held in a saline environment Resists on ground with a water table and/or hydromorphous soils up to outlet level. Low weight Easy handling Removable coalescence and easy maintenance Easy connections Devices held in stock A E DEVICES WITH PE FRAMES A E C D D G H G H B ØF ØF Installation Refer to data sheet P072. Maintenance Ensure periodically that the ventilation is not obstructed. The drainage frequency must be adapted to sludge and oil volumes intercepted. It is recommended to drain the device when the sludge level reaches 50% of the useful volume of the silt storage or when hydrocarbons rise 80% of the retention capacity of the separator (cf. NF P16-442) Take advantage from the drainage to clean the coalescence and the sealing systems. After each drainage, the device must be fi lled with water. Also check that the shutter fl eet. Reference Flow rate to be treated (l/s) Manhole Nb A B C D E Ø F G H Silt storage Volume (liters) Oil retention Volume (liters) SH2/6645/ x SH2/6645/01/ SH2/6645/ x SH2/6645/03/ SH2/6645/ x SH2/6645/06/ SH2/6645/ x SH2/6645/08/ SH2/6645/ x SH2/6645/10/ SH2/6645/ x SH2/6645/15/ Options : ANH22/14320 Oil level alarm with power supply ANH22/14506 Oil level alarm powered by a solar panel SNB/14220 Sludge layer sensor RH6069 Adjustable extension shaft in polyethylene for devices SH2/6645/01, SH2/6645/03 and SH2/6645/06 RH2/2030 Adjustable extension shaft in polyethylene for devices SH2/6645/15 23

26 OIL SEPARATOR 5 MG / L WITH SILT STORAGE V100 IN POLYETHYLENE NPBCKA/NPBCK 6647 Technical Defi nition An oil separator is a device designed to trap hydrocarbons in suspension in wastewater. It must be preceded by a silt storage unit which retains heavy matter. Oil separators fi tted with a coalescer are perfectly suited to treating water from covered car parks, petrol stations, garages. For washing areas provide a complementary V200 silt storage to obtain a volume of V300. Reminder: The oil level alarm, additional piece of equipment, is mandatory unless special derogation from the local authorities. Operation The operation of the oil separator is based on the separation by density difference insoluble pollutants contained in the runoff. Compartment allows sludge to settle and trap suspended solids (> 200 microns). Coalescence system with its large surface area allows free oil concentrate in promoting their collision. Oil then rise to the surface. The sealing system prevents the risk of the releasing of hydrocarbons. Maintenance Periodically to ensure that the ventilation is not obstructed. Frequency must be adapted to drain sludge volumes and hydrocarbon intercepted. It is recommended to drain the appliance when the sludge reaches 50% of the volume of the sludge or oil occupy 80% of the retention capacity of the separator (see NF P16-442). Enjoy the drain to clean the coalescence and the sealing system. After each discharge, the unit must be returned to water. Also check that the shutter fl eet. EN858-1 Advantages Designed in accordance with: EN and EN Tank with a 20 year anti-corrosion warranty Tested and held in a saline environment Resists on ground with a water table up to outlet level Low weight Easy handling Removable coalescence and easy maintenance Easy connections Devices held in stock Installation See sheet P060 for installation on page 49. EN858-1 D C1 B1 150 H A B F G E Sortie Sortie Δ FEE/FES E/ = 100mm 0 C Entrée Reference Flow rate to be treated(l/s) Nb. manholes A B B1 C C1 D E F G H Silt storage volume (liters) Oil retention Volume (liters) SH2/6647/20/ SH2/6647/25/ / SH2/6647/30/ Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) SNB/14220 Sludge layer sensor 24

27 Technical defi nition An oil separator is a device designed to trap and store free hydrocarbons from runoff water. The silt storage unit traps suspended solids (sand, gravel ). These oil separators without by-pass and equipped with a silt storage are designed to treat water from covered car parks, petrol stations, garages. For washing areas a complementary silt storage V200 must be provided to obtain a V300 volume. Reminder :The oil level alarm is mandatory as additional piece of equipment. OIL SEPARATORS 5 MG/L WITH SILT STORAGE V100 AND BY-PASS IN POLYETHYLENE DOKAC/DOK 6649 EN858-1 Operation The operation of the oil separator is based on the separation by density difference of insoluble pollutants contained in runoff water. The bypass system located at the entry box is used to regulate the fl ow (treatment 20% permissible fl ow). The silt storage compartment settles and traps suspended solids (>200µm). The coalescence system, with its large surface area, enables the concentration of free hydrocarbons which are bumping each other. Hydrocarbons rise then to the surface. The sealing system (shutter) prevents from any risk of hydrocarbon release. DEVICE WITH PE FRAME A E D DEVICE WITH PE MANHOLE A E ØD C C D ØD G H G H B B ØF ØF Advantages Patented design in accordance with standards : EN and EN A 20 year guarantee tank against corrosion Held in a saline environment Resists on ground with a water table and/or hydromorphous soils up to outlet level. internal by-pass tube Low weight Easy handling Removable coalescence and easy maintenance Easy connections Devices held in stock Installation Refer to data sheet P072 Maintenance Ensure periodically that the ventilation is not obstructed.the drainage frequency must be adapted to sludge and oil volumes intercepted. It is recommended to drain the device when the sludge level reaches 50% of the useful volume of the silt storage or when hydrocarbons rise 80% of the retention capacity of the separator (cf. NF P16-442) Take advantage from the drainage to clean the coalescence and the sealing systems. After each drainage, the device must be fi lled with water. Also check that the shutter fl eet. Reference Flow rate to be treated (l/s) Manhole Nb A B C D E Ø F G H Silt storage Volume (liters) Oil retention Volume (liters) SH2/6649/ x SH2/6649/03/ SH2/6649/ x SH2/6649/06/ SH2/6649/ x SH2/6649/08/ SH2/6649/ x SH2/6649/10/ SH2/6649/ x SH2/6649/15/ Options : ANH22/14320 Oil level alarm with power supply ANH22/14506 Oil level alarm powered by a solar panel SNB/14220 Sludge layer sensor RH6069 Adjustable extension shaft in polyethylene for devices SH2/6649/03 and SH2/6649/06 RH2/2030 Adjustable extension shaft in polyethylene for devices SH2/6649/15 25

28 OIL SEPARATOR 5 MG / L WITH SILT STORAGE V100 AND BY-PASS IN POLYETHYLENE DOKAC/DOK 6648 Technical Defi nition An oil separator is a device designed to trap hydrocarbons in suspension in wastewater. It must be preceded by a silt storage unit which retains heavy matter. Oil separators with bypass fi tted with a coalescer are perfectly suited to treating water from covered car parks, petrol stations, garages. Reminder: The oil level alarm, additional piece of equipment, is mandatory unless special derogation from the local authorities. Maintenance Periodically to ensure that the ventilation is not obstructed. Frequency must be adapted to drain sludge volumes and hydrocarbon intercepted. It is recommended to drain the appliance when the sludge reaches 50% of the volume of the sludge or oil occupy 80% of the retention capacity of the separator (see NF P16-442). Take advantage of the drain to clean the coalescence and the sealing system. After each discharge, the unit must be returned to water. Also check that the shutter fl eet. Operation The operation of the oil separator is based on the separation by density difference insoluble pollutants contained in the runoff. The bypass system located at the entry box is used to regulate the fl ow (20% of treatment permissible fl ow). Compartment allows sludge to settle and trap suspended solids (> 200µm). Coalescence system with its large surface area allows free oil concentrate in promoting their collision. Oil then back to the closure system surface.le avoids any risk of release of hydrocarbons. Advantages Designed in accordance with: EN and EN Tank with a 20 year anti-corrosion warranty Tested and held in a saline environment Resists on ground with a water table up to outlet level Low weight Easy handling Removable coalescence and easy maintenance Easy connections Devices held in stock Installation See sheet P060 for installation on page 49. EN858-1 D C1 B1 150 H A B F G E Sortie Sortie Δ FEE/FES = 100mm C Entrée Reference Flow rate to be treated(l/s) Allowable flow rate (l/s) Nb. manholes A B B1 C C1 D E F G H Silt storage volume (liters) Oil retention Volume (liters) SH2/6648/20/ SH2/6648/25/ / SH2/6648/30/ Options : ANH22/14320 Oil level alarm with power supply (refer to data sheet 4982 page 34) ANH22/14506 Oil level alarm powered by solar panel (refer to data sheet 4981 page 33) SNB/14220 Sludge layer sensor 26

29 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE V200 POLYETHYLENE 6644 Technical Defi nition An oil separator is a device designed to trap hydrocarbons in suspension in wastewater. It must be preceded by a silt storage unit which retains heavy matter. The Environmental Code prohibits the discharge into surface and/or underground water of lubricants, new or spent oils. Oil separators fi tted with a coalescer are perfectly suited to treating water from areas subject to the requirements of Order 261 bis, Section 1434 concerning fl ammable liquids (decree of 07/01/03) (service stations, distribution stations fuel, etc.). Each device is provided with a polyethylene screw dawn cover. An extraction system for sludge located in the silt storage unit is provided in our devices. The oil level alarm, additional piece of equipment, is mandatory unless special derogation from the local authorities. Operation The operation of the oil separator is based on gravity separation of insoluble matters in water. Water full of hydrocarbons enters the device where the plunging wall forced them to descend, the turbulences on surface are so limited. In the central part of the device, hydrocarbons of lower density than water rise to the surface where they are trapped. A security system with a float plugs the outlet pipe when the oil storage capacity has been reached. Features - Retention Capacity : 10 l per l/s. - Treatment Capacity : 3 to15 l/s. - The volume of silt storage is calculated on the basis of 200l per l/s. - Separating output : 99.88% (below to 5 mg/l) at a density of Maintenance As soon as the retention capacity is reached, the alarm indicates that sludge and hydrocarbons must be removed. In the absence of control and history, completely drain the unit once a year. Immediately after drainage, re-fi ll the separator with clean water up to the outlet level and check that the fl oat is correctly positioned on the upper level of the apparatus. For more information refer to standards EN and NF P INSTALLATION WITH CONCRETE SLAB (IF THE WATER INLET LEVEL / GROUND LEVEL IS SUPERIOR TO 500 MM OR IF VEHICLES WILL PASS OVER THE AREA LESS THAN 3 LINEAR METERS) Installation The device must be buried in the outside of the building, as close as possible to the place to be treated. The bottom of the hole must be perfectly fl at and covered with 10 cm of sand. The backfi ll must be sand, and in any case with stone, gravel. Fill the device with clean water up and carry out lateral backfi ll at the same time. In case of passing vehicles less than 3 linear meters, overloading, or embankment height greater than 50 cm relative to ground outlet level, a concrete slab must be poured resting on stable ground in order to withstand the strains imposed. The covers should be level with the fi nished ground and must remain accessible. Vent pipes must be connected. Option : polyethylene extension shaft (Ref : RH602) of 250mm is available. DEVICE WITH PE FRAME EN Vent pipe Ø Extraction device 3. Screw-on frame OPTION 4. Extension shaft RH602 ANH2 PS Oil level alarm powered by a solar panel Reference Size A B Width D E F G H Silt storage Volume Separator Volume SHDOC SHDOC SHDOC SHDOC SHDOC Options : RH602 Polyethylene screw-on extension shaft Height 250 mm 27

30 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE FLOW RATE OVER 50 L / S PAINTED STEEL IA 4918 Technical Defi nition Separator sized to accommodate fl ow rates greater than 50 l/s. The cylindrical design is adapted to resist ground pressure and sizing generating important fl ow rates. Oil separator, provided with a steel sleeve to the inlet and to the outlet, sandblasted steel S235JRG2 SA2, 5 and coated with epoxy paint inside and outside in accordance with the standard EN 858, operating in gravity fl ow. It is provided with a silt storage and a polyethylene siphonic partition This set enables to block fl oatings in the silt storage unit and directs the fl ow rate downward. The coalescence in the separation zone is for separating oils. The rocking shutter system in polyethylene with a nitrile joint prohibits oil discharge at the outlet. Manholes remain accessible in accordance with EN 476. Marking on the separator made in accordance with EN 858. Technical Advantages Sizing made custom => allow adjustment to site conditions. Sizing Calculation => Warranty for mechanical resistance Washable coaslescers => Warranty of an easy maintenance Closing of the shutter by a nitrile joint => Resistant to most effl uents containing hydrocarbons STS type Oil separator 5 mg/l CE marked with silt storage made of steel S235JRG2, sandblasted SA2,5 and provided with an internal /external epoxy coating, FRANCEAUX brand or similar reference SH4918 with a honeycomb coalescer in polypropylene in accordance with EN 858. Options Frame designed for a quick installation => Quick installation on site with anchoring straps Cathodic Protection => Protection against stray currents Ladders, aspirations => Easy use Important Regular maintenance of this equipment in accordance with EN and NF P dated November 2007 is required. The System of extension shaft(s) and cover(s) in accordance with EN 124 are not supplied. Become familiar with the installation instructions of steel oil separators. 28

31 OIL SEPARATOR CE 5 MG / L SILT STORAGE WITH BY-PASS UPSTREAM OR DOWNSTREAM FLOW RATE OVER 50 L / S PAINTED STEEL IACD 4920 Technical Defi nition Separator sized to accommodate fl ow rates greater than 50 l/s. The cylindrical design is adapted to resist ground pressure and sizing generating important fl ow rates. Oil separator, provided with a steel sleeve to the inlet and to the outlet, sandblasted steel S235JRG2 SA2, 5 and coated with epoxy paint inside and outside in accordance with the standard EN 858, operating in gravity fl ow. It is provided with a silt storage and a polyethylene siphonic partition This set enables to block fl oatings in the silt storage unit and directs the fl ow rate downward. The coalescence in the separation zone is for separating oils. The rocking shutter system in polyethylene with a nitrile joint prohibits oil discharge at the outlet. The upstream storm drain outfall directs the fl ow rate to the silt storage unit. Bypass upstream or downstream allows to divert the surplus to the outlet in case of exceptional rainfall event. It also prevents the resuspending of settled sludge. Manholes remain accessible in accordance with EN 476. Marking on the separator made in accordance with EN 858. Technical Advantages Sizing made custom => allow adjustment to site conditions. Sizing Calculation => Warranty for mechanical resistance Washable coaslescers => Warranty of an easy maintenance Closing of the shutter by a nitrile joint => Resistant to most effl uents containing hydrocarbons STS type Oil separator 5 mg/l CE marked with silt storage made of steel S235JRG2, sandblasted SA2,5 and provided with an internal /external epoxy coating, FRANCEAUX brand or similar reference SH4920 with blade series in polypropylene and bypass in PVC in accordance with to EN 858. Options Frame designed for a quick installation => Quick installation on site with anchoring straps Cathodic Protection => Protection against stray currents Ladders, aspirations => Easy use Important Regular maintenance of this equipment in accordance with EN and NF P dated November 2007 is required. The System of extension shaft(s) and cover(s) in accordance with EN 124 are not supplied. Become familiar with the installation instructions of steel oil separators. This type of device must not be installed on areas of fuel distribution. 29

32 OIL SEPARATOR CE 5 MG / L WITH SILT STORAGE FLOW RATE OVER 50 L / S GRP IAPRV 6668 GUARANTEE 20 YEARS AGAINST CORROSION Technical Defi nition Separator sized to accommodate fl ow rates greater than 50 l/s. The cylindrical design is adapted to resist ground pressure and sizing generating important fl ow rates. oil separator in glass-fi bre reinforced polyester, meeting the requirements of EN 858-1, fi tted with a cuff to the PVC inlet and outlet for the connection, and operating in gravity fl ow. It is provided with a silt storage and a polyethylene siphon partition. This set enables to block fl oatings in the silt storage unit and directs the fl ow rate downward. The coalescence in the separation zone is for separating oils. The rocking shutter system in polyethylene with a nitrile joint prohibits oil discharge at the outlet. Manholes remain accessible in accordance with EN 476. Marking on the separator made in accordance with EN 858. Technical Advantages Sizing made custom => allow adjustment to site conditions. Sizing Calculation => Guarantee for mechanical resistance Washable coaslescers => Guarantee of an easy maintenance Closing of the shutter by a nitrile joint => Resistant to most effl uents containing hydrocarbons Choice of materials (polyester, PVC, PP) => No corrosion CCTP type Oil separator 5 mg/l CE marked with silt storage and convex ends in glass-fi bre reinforced polyester, FRANCEAUX brand or similar reference SH3/6668 with blade series in polypropylene in accordance with EN 858. Options Scales, aspiration kits, quick installation frames => Easy operation, quick installation Important Regular maintenance of this equipment in accordance with EN and NF P dated November 2007 is required. The System of extension shaft(s) and cover(s) in accordance with EN 124 are not supplied. Become familiar with the installation instructions of polyester oil separators. 30

33 OIL SEPARATOR CE 5 MG / L SILT STORAGE AND BY-PASS UPSTREAM OR DOWNSTREAM FLOW RATE OVER 50 L / S GRP IADPRV 6669 GUARANTEE 20 YEARS AGAINST CORROSION Technical Defi nition Separator sized to accommodate fl ow rates greater than 50 l/s. The cylindrical design is adapted to resist ground pressure and sizing generating important fl ow rates. oil separator in glass-fi bre reinforced polyester, meeting the requirements of EN 858-1, fi tted with a cuff to the PVC inlet and outlet for the connection, and operating in gravity fl ow. It is provided with a silt storage and a polyethylene siphon partition. This set enables to block fl oatings in the silt storage unit and directs the fl ow rate downward. The coalescence in the separation zone is for separating oils. The rocking shutter system in polyethylene with a nitrile joint prohibits oil discharge at the outlet. The upstream storm drain outfall directs the fl ow rate to the silt storage unit. Bypass upstream or downstream allows to divert the surplus to the outlet in case of exceptional rainfall event. It also prevents the resuspending of settled sludge. Manholes are accessible according to EN 476 Marking the separator made in accordance with EN 858. Technical Advantages Sizing made custom => allow adjustment to site conditions. Sizing Calculation => guarantee for mechanical resistance Washable coaslescers => guarantee of an easy maintenance Closing of the shutter by a nitrile joint => Resistant to most effl uents containing hydrocarbons Choice of materials (polyester, PVC, PP) => No corrosion STS type Oil separator 5 mg/l CE marked with silt storage, bypass and convex ends in glass-fi bre reinforced polyester, FRANCEAUX brand or similar reference SH3/6669 with blade series in polypropylene and bypass PVC in accordance with EN 858. Options Scales, aspiration kits, quick installation frame => Easy operation, quick installation Important Regular maintenance of this equipment in accordance with EN and NF P dated November 2007 is required. The System of extension shaft(s) and cover(s) in accordance with EN 124 are not supplied. Become familiar with the installation instructions of polyester oil separators. This type of device must not be installed on areas of fuel distribution. 31

34 SELECTION TABLE OIL LEVEL ALARMS OILS SLUDGE OVERFLOW GSM SOLAR SOLAR GSM REFERENCE ANH22/14320 sheet 4982 page 43 ANH22/15200 sheet 4982 page 43 ANH22/14506 sheet 4981 page 42 ANH22/14507 sheet 4981 page 42 ANB22/14321 sheet 4978 page 44 ANL22/14321 sheet 4979 page 45 STANDARD IP65 Box (-20 / +60 C) IP68 oil sensor 5 linear meter cable Intrinsically safe [EExia] IIC. degree of pollution 2 BOX ABS 185X185 (depth 62mm) ABS 185X185 (depth 62mm) PRV 330x430 (200mm depth) PRV 330x430 (200mm depth) ABS 185X185 (depth 62mm) ABS 185X185 (depth 62mm) ACOUSTICS YES YES NO NO YES YES APPROVAL ATEX VISUAL SMS (8 issues in reception) POWER BUZZER SOUND LEVEL (0.1 m) nb of relays Baseefa 08 ATEX 0110 (England) A warning message on housing Baseefa 08 ATEX 0110 (England) A warning message on housing Baseefa 08 ATEX 0171X (England) A warning message on housing Baseefa 08 ATEX 0171X (England) A warning message on housing Baseefa 08 ATEX 0110 (England) A warning message on housing Baseefa 08 ATEX 0110 (England) A warning message on housing NO YES NO YES NO NO Vac 50/60 Hz Vac 50/60 Hz 12VDC SOLAR PANEL 12VDC SOLAR PANEL Vac 50/60 Hz Vac 50/60 Hz >80 db >80 db - - >80 db >80 db 1 (3A-250Vac- 100Vcc) 2 (3A-250Vac- 100Vcc) 1 (100mA- 12Vcc) 1 (100mA- 12Vcc) 1 (3A-250Vac- 100Vcc) 1 (3A-250Vac- 100Vcc) FIXING WALL WALL PILLAR PILLAR WALL WALL OPTIONS reference BEACON GYRO/ANH YES YES YES (in series) YES YES YES SOLENOID VALVE ELT NF YES YES NO NO YES YES SOLENOID VALVE ATEX SLUDGE BLANKET SENSOR IP68 HIGH LEVEL SENSOR IP68 SOLENOID- WKB2-3/4 YES YES NO NO YES YES SNB/14220 YES YES YES YES YES YES SNL/14210 YES YES YES YES YES YES 32

35 OIL LEVEL ALARM POWERED BY SOLAR PANEL ALARM 4981 Use This alarm system detects the oil level in the separator compartment just before shutter. The photovoltaic alarm is suitable for isolated locations where there is no electricity supply available. In addition, the photovoltaic cell produces electricity necessary to the plant by transforming a portion of solar radiation. Operation The control unit can control up to 6 sensors installed on two different separators (3 sensors per tank). The unit controls the connected sensors every 30 minutes (adjustable frequency). The current state is displayed on the 2X16 LCD screen located on the front of the unit. Oils are detected by conduction, water acts as a conductor while oils act as isolators. The sensor consists of two stainless steel parts, when one part is immersed in oil, a signal is sent to the control box which triggers the alarm. The control unit detects the alarm condition of the sensor, it comes in two versions : - One reported alarms with a visual noisy signal. - The second transmits the state of the sensors by GSM (SMS on mobile phone). A central alarm signal, a modem, or others external alarm devices can also be connected to the relay. Technical Defi nition - Ambient temperature : -20 C to 50 C - 6 sensor inputs - Voltage : 12 VDC - Relay outlet : 12 VDC, 100 ma - Box protection : IP65 - Intrinsically safe : [EX ia] IIC (-20 C <= Ta <= +50 C) - ATEX Certifi cation : Base efa08atex0171x - Length of sensor cable: 5 m Oil level alarm powered by a solar panel Maintenance The sensors can be exposed to harsh environments. it is recommended to inspect and clean them regularly. The maintenance of the pieces of the control unit may not be performed by the user. For any repair, please contact us. Advice and Standards The oil level alarm is a compulsory equipment of an oil separator in accordance with Standard EN858. Installation Refer to the installation instructions P083 concerning steel oil separators. Installation and use instructions are delivered with the alarm. The maximum length of the sensor cable is 200 m. All connections must be made by a professionnal, assistance may be offered as an option. Is is essential that the solar panel is facing south, his line of sight to the sun is clear and it is free of foreign matter (for instance : leaf) Reference ANH22/14506 ANH22/14507 Designation Visual and sound oil level alarm IP65 powered by a solar panel Visual and sound level alarm IP65 + GSM powered by a solar panel SNH/14200 Sensor detecting the oil level SNB/14220 Sensor detecting the sludge level SNL/14210 CR-ANH MR-ANH Sensor detecting the liquid level Extension cable ATEX Connecting pipe ATEX 33

36 OIL LEVEL ALARM ALARM 4982 Use This alarm system detects the oil level in the separator compartment just before shutter. The alarm is suitable for new locations where electricity supplyis easily available making installation effi cient and economical. Operation The control unit can control up to 3 sensors. The unit controls the connected sensors every 30 minutes (adjustable frequency). The current state is displayed on the 2X16 LCD screen located on the front of the unit. Oils are detected by conduction, water acts as a conductor while oils act as isolators. The sensor consists of two stainless steel parts, when one part is immersed in oil, a signal is sent to the control box which triggers the alarm. The control unit detects the alarm condition of the sensor, it comes in two versions : - One reported alarms with a visual noisy signal. - The second transmits the state of the sensors by GSM (SMS on mobile phone). A central alarm signal, a modem, or others external alarm devices can also be connected to the relay. Technical Defi nition - Ambient temperature : - 20 C to 50 C - 3 sensor inputs - Voltage : 230 VAC + / -10% - Relay outlet : 230Vac, 3A - Box protection : IP65 - Intrinsically safe : [EX ia] IIC (-20 C <= Ta <= +50 C) - ATEX : Base efa08atex0110x - Length of sensor cable : 5 m Alarm Maintenance The sensors can be exposed to harsh environments. it is recommended to inspect and clean them regularly. The maintenance of the pieces of the control unit may not be performed by the user. For any repair, please contact us. Advice and Norms The oil level alarm is a compulsory equipment of an oil separator in accordance with Standard EN858. Installation Refer to the installation instructions P083 concerning steel oil separators ; P084 for polyethylene oil separators. Installation and use instructions are delivered with the alarm. The maximum length of the sensor cable is 200 m. All connections must be made by a professionnal, assistance may be offered as an option. Is is essential that the solar panel is facing south, his line of sight to the sun is clear and it is free of foreign matter (for instance : leaf) Reference Designation ANH22/14320 Visual and sound oil level alarm IP65 ANH22/15200 Visual and sound oil level alarm IP65 + GSM SNB/14220 Sensor detecting the sludge level SNL/14210 Sensor detecting the liquid level CR-ANH Extension cable ATEX MR-ANH Connecting pipe ATEX 34

37 SLUDGE LEVEL ALARM ANB22/14321 ALARM Use Detection of the maximum level of sludge Acoustic alarm device incorporated 1 oulet relay inverter Detection of faulty sensor with 5 m cable Repeat function and alarm memory Certifi ed Ex (ATEX) Operation Ultrasonic sensor comprising a transmitter and a receiver. If the wave emitted by the transmitter is blocked by mud and does not reach the receiver, the relay activates the alarm. The alarm relay has incorporated an acoustic device. A central alarm system, a modem, a fl ashing light or external alarm device can be connected to the relay. The sensor associated with the relay make the difference between the liquid and the sludge, and between liquid and air. We detect thus a sludge level or a level loss (leakage). Installation and connections, please contact us or call a licensed electrician. To activate the installation, call a hotline indicated on the front of the box and you will have the activation code. EN858-1 Advice and Standards The sludge detection assembly can be coupled to the oil layer detection sensor (Ref. SNH/14200) and to the high level detection sensor (Ref. SNL/14210). The installation must not exceed 200 meters in a confi guration in a IIC area and whatever the sensors number. Possibility of wiring a light beacon (Ref. GYRO/ANH). Technical features of the relay Material : ABS Dimensions : 185 mm x 185 mm, depth: 62 mm Power supply : 230 VAC ± 10%. frequency : 50-60Hz Consumption : 6 VA / 4,5 VA (Max/Nominal) Relay outlet 1 : contact SPCO volt free changeover (normally closed) 3 A, 250 VAC VAC/100 Intensity breakdown : F100 ma V 3 sensor inlets: oil sensor, high level sensor, sludge blanket Ambient temperature: -25 C / + 50 C Confi guration : Programming with an activation code Enclosure : IP65 (against dust and water jets) Electrical protection : Class II. Protection internal fuse: FS1 = 63 ma, 315 ma = FS2, FS3 = 50 ma Sound buzzer : > 80 db (0.1 m distance) audible frequency : 4kHz Degree of pollution : 2 Approval : Baseefa (England) ATEX Certifi cation : Baseefa08 ATEX 0110 Sensor Specifi cations 5 meter cable The sensor can be connected only to the internal power supply of the box Supply voltage : 13 Vcc max Ambient temperature : - 20 C/+ 50 C Protection IP68 Certifi cation : Ex ia IIC T3 Control responsible agency : international Baseefa (England) ATEX Certifi cation : Baseefa08 ATEX 0110 Warning! The box must be installed outside ATEX zone. The control box should never be drilled to allow the passage of cables. This could compromise the certifi cation and therefore the safety of the equipment. A intrinsically safe junction box should be used when the cable sections must be reduced to the passage in the cable gland. 35

38 ALARM DETECTING OVERFLOW ANL22/14321 ALARM Use Detection of the separator maximum level preventing any risk of overfl ow Acoustic alarm device incorporated 1 oulet relay inverter Detection of faulty sensor with 5 m cable Repeat function and alarm memory Certifi ed Ex (ATEX) Operation The sensor is equipped with an electronic circuit which transmits a high frequency signal thanks to an oscillator. This signal varies when the sensor is placed in water, air or oil. The alarm relay has incorporated an acoustic device. A central alarm system, a modem, a fl ashing light or external alarm device can be connected to the relay. The sensor associated with the relay detects the overfl ow (maximum level) of the separator, and prevents any overfl ow. Installation and connections, please contact us or call a licensed electrician. EN858-1 Advice and Standards The high level detection assembly can be coupled with the detection alarm of oil layers ANH/14200 and with the mud detection sensor SNB/ The installation must not exceed 200 meters in a confi guration in a IIC area and whatever the sensors number. Possibility of wiring a light beacon (Ref. GYRO/ANH). Technical features of the relay Material : ABS Dimensions : 185 mm x 185 mm, depth: 62 mm Power supply : 230 VAC ± 10%. frequency : 50-60Hz Consumption : 6 VA / 4,5 VA (Max/Nominal) Relay outlet 1 : contact SPCO volt free changeover (normally closed) 3 A, 250 VAC VAC/100 Intensity breakdown : F100 ma V 3 sensor inlets: oil sensor, high level sensor, sludge blanket Ambient temperature: -25 C / + 50 C Confi guration : Programming with an activation code Enclosure : IP65 (against dust and water jets) Electrical protection : Class II. Protection internal fuse: FS1 = 63 ma, 315 ma = FS2, FS3 = 50 ma Sound buzzer : > 80 db (0.1 m distance) audible frequency : 4kHz Degree of pollution : 2 Intrisincally Safe : (Eexia) IIC Approval : Baseefa (England) ATEX Certifi cation : Baseefa08 ATEX 0110 Sensor Specifi cations 5 meter cable The sensor can be connected only to the internal power supply of the box Supply voltage : 13 Vcc max Ambient temperature : - 20 C/+ 50 C Protection IP68 Certifi cation : Ex ia IIC T3 Control responsible agency : international Baseefa (England) ATEX Certifi cation : Baseefa08 ATEX 0110 Warning! The box must be installed outside ATEX zone. The control box should never be drilled to allow the passage of cables. This could compromise the certifi cation and therefore the safety of the equipment. A intrinsically safe junction box should be used when the cable sections must be reduced to the passage in the cable gland. The box is IP65 and the sensor IP68. 36

39 BOX OR JUNCTION SLEEVE CABLE FOR HYDRO ATEX ALARM BMJ 4977 Use It allows to extend the connection when the oil sensors, sludge sensors, or high level sensors are located more than 5 m from the electrical box. They also guarantee the proper functioning of the system and compliance with the ATEX standard of the installation with its cable. Technical features of the junction box Reference: BOITIER-JONCTION Possibility of connecting 2 sensors (2 inlets, 1 outlet) : Oil detection sensor and high level sensor Sludge detection sensor and high level sensor IP67 protection Box length : 100 mm Box depth : 48mm Case height : 66 mm Overall height (with cable gland) : 92 mm Weight: 0.27 kg The box is ATEX approved EN858-1 Technical features of the junction sleeve Reference : MR-ANH Connecting a sensor (1 inlet, 1 outlet) : Oil detection sensor High level sensor Sludge sensor IP67 protection Sleeve diameter : ø 28 mm Sleeve length : 108 mm Weight: 0.06 kg it has the advantage of being housed in a sheath The sleeve is ATEX approved Technical features of the cable Reference : CR-ANH When you need to extend your connection, the whole loop must not exceed a resistivity of 20 Ω/m (for the oil sensor) and 10 Ω/m for the high level sensor and sludge sensor. The installation must not exceed 250 meters for connection of a oil sensor and 100 meters for connection of two sensors (oil / high level or sludge high level). Cable Ø : 5 mm (cable sold by the linear meter) CAUTION : The cable(s) of the sensors should be inserted into sheaths independent of power cables (disturbances may affect the measured signal). 37

40 ACCESSORIES FOR OIL SEPARATOR STEEL RANGE RH 4984 Defi nition Extension shafts for oil separators are designed and coated blasted steel which ensures their strength and duration. They are designed to provide freeze protection and let access to the frame. Access to the separator is indeed indispensable for its maintenance and good operation. They are designed for separators with CE marking and with EN 1825, EN858 and EN124 standards. STEP 1 STEP 3 STEP 2 End of the separator reference without protection Choose the appropriate reference to the moving load RP1L RP1T RP2L RP2T Frame 125 KN-577 x 673 Frame 250 KN-577 x 673 Possible adjustment of 150 mm Qty Qty Qty Qty Reference Reference Longitudinal extension shaft H200/ TF125P/H2035L TF250P/H2035L Transverse extension shaft H200/ TF125P/H2035T TF250P/H2035T Longitudinal extension shaft H350/ TF125P/H3550L TF250P/H3550L Transverse extension shaft H350/ TF125P/H3550T TF250P/H3550T Longitudinal extension shaft H500/ TF125P/H5065L TF250P/H5065L Transverse extension shaft H500/ TF125P/H5065T TF250P/H5065T Longitudinal extension shaft H650/ TF125P/H6580L TF250P/H6580L Transverse extension shaft H650/ TF125P/H6580T TF250P/H6580T Longitudinal extension shaft H800/ TF125P/H8095L TF250P/H8095L Transverse extension shaft H800/ TF125P/H8095T TF250P/H8095T End of the reference separator without protection Choose the appropriate reference to the moving load RG1L RG2T RG3T RG4T RG5T Frame 125 KN-577 x 922 Frame 250 KN-577 x 922 Possible adjustment of 150 mm Qty Qty Qty Qty Qty Reference Reference Longitudinal extension shaft H200/350 1 TF125G/H2035L TF250G/H2035L Transverse extension shaft H200/ TF125G/H2035T TF250G/H2035T Longitudinal extension shaft H350/500 1 TF125G/H3550L TF250G/H3550L Transverse extension shaft H350/ TF125G/H3550T TF250G/H3550T Longitudinal extension shaft H500/650 1 TF125G/H5065L TF250G/H5065L Transverse extension shaft H500/ TF125G/H5065T TF250G/H5065T Longitudinal extension shaft H650/800 1 TF125G/H6580L TF250G/H6580L Transverse extension shaft H650/ TF125G/H6580T TF250G/H6580T Longitudinal extension shaft H800/950 1 TF125G/H8095L TF250G/H8095L Transverse extension shaft H800/ TF125G/H8095T TF250G/H8095T Blanking plate 577 x 673 Blanking plate 577 x 922 Reference TR4/P TR4/G INSTRUCTIONS STEP 1 : Identify the end of the separator reference and keep in mind the number of closures indicated in the corresponding column. STEP 2 : Choose the height of the extension shaft (note : this is not the inlet level but the height from the top of the separator). STEP 3 : Determine the reference of the protection according to the moving load. IMPORTANT : Quantities in green can be reduced by replacing some sets extension shaft/frame with steel blanking plates TR4/P or TR4/G (factory made) 38

41 ADJUSTABLE EXTENSION SHAFTS FOR OIL SEPARATOR PE RANGE RHPEH 6069 Defi nition Extension shafts in high density polyethylene. This material is stable and durable. Extension shafts adjustable from 300 to 450 mm and designed to provide freeze protection and let access to the frame. Access to the separator is indeed indispensable for its maintenance and good operation. Use Extension shafts suitable for polyethylene separators with rectangular frame. Installation Put the extension shaft on the U-frame of the separators and set the desired height by drilling and screwing it. Reference A B D RH à x x

42 ANCHORING STRAPS 10T - CA3/6394/10T FOR SEPARATOR IN ACCORDANCE WITH STANDARD NF-EN CEINT 6394 Defi nition These straps are used to secure the separators on ballast concrete slab, for installation on ground with a water table. The straps are supplied with a «winch» system which streches the straps easily once entangled in the concrete slab. In accordance with Directive NF-EN : A label on each part containing technical features and marking. A safety factor of 2 on the leg and hooks and 3 on the strap. A 7% maximum elongation on the strap to the maximum lashing capacity. Regular test prescribed for lashing capacity. lashing capacity and rupture X 2. EN858-1 Installation Positioning straps as shown below. Even distribution of the straps along the length of the separator (spacing «A» about 2.5 m) Simple (without effort) and even tension of the straps Do not put in direct contact tensioner on the tank (painting) Anchoring irons (not supplied) The «winch» must be entangled in the reinforced concrete slab and an anchoring iron (not supplied) must be placed away from the tank (see diagram). Technical Advantages Rotproof Resistance Simple, easy and progressive clamping system anchoring strap Ceinture d'ancrage anchoring Fer d'ancrage iron (not(hors supplied) fournitures) reinforced Dalle concrete béton slab armé Winch winch Lit sand de sable bed (20 (20 cm) cm 40

43 SLUDGE EXTRACTION DEVICE OD4/ KIT-ASPI 4980 Operation Remote extraction device by a symmetric connection DN80 located to the left, to the outlet of the device. This system is used to extract sludge (pumping). This device is valid for both confi gurations (cylindrical manholes and total accessibility) The symmetric connection and the screwed end (not fi t- ted) are to be sticked at the end of the pipe. Make the connection of the pressure PVC pipe PN16 on the outlet of the suction (necessary number of bends to provide). 41

44 OIL BELT TRANSFER OD4/2102 CAPT 4988 Use This system allows to recover hydrocarbons through a chute and evacuate them to a holding tank. It can also delay the intervention of the pumper when a storage tank is placed near the separator, and ensure safety in the event of accidental spill. Operation The gravity discharge of hydrocarbons is carried by the chute inside the separator and is released to the outside by a spur ND20 (diameter ø 20mm) on the left lateral side* (default) of the separator. The system operates through the handle of the valve located at the manholes (cylindrical or rectangular) of the separator. When the separator is saturated with oil and that the fl oat is embedded in the layer, open the valve. Closing the valve as soon as all of the oil layer was removed. * If the installation should be done right, please let us know. Setting A preset is done in factory. The edge of the chute must be between 10 and 20 mm below the water outlet level. The adjustment is made by screwing in/screwing out the screw on the side of the chute. We recommend you to calibrate the chute on the top rail, to have a greater range of adjustment in case the calibration is changed. CAUTION : To avoid obstruction of the connection system pipe, the slope must be suffi ciently large. Installation dimensions of the chute : TYPE OF DEVICE Y (mm) X (mm) Setting of the chute H (mm) SH4808/01/ SH4804/01/00 SH4824/01/ SH4814/03/00 SH4808/03/ SH4804/03/00 SH4810/03/00 SH4824/03/ SH4814/06/00 SH4808/06/ SH4810/06/00 SH4804/06/00 SH4824/06/ SH4808/08/ SH4814/08/ SH4810/08/00 SH4804/08/00 SH4824/08/ SH4808/10/00 SH4814/10/ SH4808/15/ SH4808/15/ SH4810/15/00 SH4804/15/00 SH4824/15/ SH4814/20/00 SH4808/20/ SH4810/20/00 SH4804/20/00 SH4824/20/ SH4810/25/00 SH4804/25/00 SH4824/25/ SH4810/30/00 SH4824/30/00 SH4804/30/ SH4810/35/00 SH4804/35/00 SH4824/35/ SH4810/40/00 SH4824/40/00 SH4804/40/ SH4810/50/00 SH4804/50/00 SH4824/50/ SH4730/ SH4730/03 - SH4730/ Length of wire 5 m (default) electrical box Oil separator Oil belt transfer Oil detection sensor Pipe (not supplied) Solenoid valve Reference: ELTV NF Storage tank Position of the system on the inlet side of the separator. Pitting ø 26.9 mm in the axis of the manhole at the level of the coalescence Y (mm) pitting position X (mm) 42 chute

45 EXTERNAL CATHODIC PROTECTION OD/2145 ANODE 4985 Constitution and features It is made of magnesium and backfi ll, all contained in a cotton bag. Length : 400 mm Diameter : 200 mm Weight of AZ63 magnesium anode : 5 kg Total weight : 15 kg Backfi ll corrosion control : 10 kg Cable cross-section : 6 mm² Cable length : 10 meters Electronegative potential of magnesium : volt Strength of current available : 10 to 20 Ma Utilization factor : 50% Protectable surface by anode: 25 m²* Life cycle : 10 years* There is an option, an interconnection box to verify the effi - ciency of the anodes and control the wear rate. This box can be set in the concrete manhole (see diagram). Assembly (in accordance with NF P , Novembre 2007). It is important to ensure that the tanks are well insulated of all the other metal structure and be sure the terracing and embankment works of the tanks are completed. Connect the cathodic protections at the level of the reinforcements situated on the parallelipedic and cylindrical tanks (hole). The electric cable of the anode will be placed in a sheath before installation. The anodes must be wet. Interconnection box option : it controls the electrical measurements of the polarization of the cathodic protection. It is an aluminium box containing a copper bar* *Values only valid in the presence of a coating which are resistant and where the isolation is greater than 104 m² and of an electrlyte with a neutral Ph and resistivity less than 50 m. Technical Advantages The cathodic protections are used to slow corrosion of the metal particularly due to the existence of stray currents in the ground. This slowing down is achieved by the provision of a more electronegative potential than steel through an anode called «sacrifi cial» composed, for most of them, of magnesium or zinc in specifi c applications (saline). Operation An «sacrificial» anode in magnesium is consumed progressively on contact with stray currents existing in the ground because its potential is more electronegative than steel. Electronegative potential of steel : volt Electronegative potential of magnesium : volt Wiring diagram fo a cylindrical device according to NF P (November 2007) : 43

46 GRAVEL FILTER DRAIN WITH FIREWALL AVCF01 AVCF 1/ Disposal of the drains on helipad The drain gravel fi lter is a part of the equipment of a helipad on the terrace. This is a safety device preventing the fi re spread to other parts of buildings when there is a fuel fl ow or when there is a crash landing of a helicopter. Filter drains shall be fi lled with gravel under the grate and water in the silt storage siphon. Firewall drains Gravel fi lters are constituted by a cylindrical tank made of galvanized steel with a 65 cm inside diameter containing gravel size 10/20 mm to a thickness of about 20 cm. These gravel have the ability to absorb a fl ow rate of about 5 to 10 l/sec (depending on the gravel type). The drain is formed in the upper portion of a gravel fi lter covered by a grating and a cast iron installation frame (700x kN) and a silt storage siphon as a fi rewall at the bottom. Connections to the network are made using fl at fl anges. Oil detection device, brand FRANCEAUX ANH22/14320 or similar, ATEX certifi ed. IP65 box. Features Water volume in the siphon : 46 dm3 Total weight : 170 kg Grating and frame weight : 77 kg Gross weight : 304 kg Gravel density : 1450 kg/dm3 See diagram below for other specifi cations *stainless steel on request. 44

47 GRAVEL FILTER DRAIN WITH FIREWALL AVCF01 AVCF 2/ HELIPAD CATEGORY 3 Implantation Drains are installed in the landing zone. They are connected to the rain water network via a device separating hydrocarbons. This device may be installed either directly under the terrace, at the foot of the building or distributed between these two locations. The device must include the following parts : Drain with a gravel fi lter acting as a fi rewall Silt storage siphon Silt storage high capacity (silt storage foot drop regulating the fl ow rate) Oil separator with self shutter and evacuation device for hydrocarbons in excess Tank collecting a massive fuel fl ow rate of an equivalent capacity to the volume of the helicopers tanks (see classifi cation below). Remarks : It is possible to simplify the installation by removing the tank when the retention capacity of the separator is greater than the capacity of the helicopters tanks. Maximum capacity of the helicopters tanks : group 3 = 2000 liters group 4 = 1000 liters HELIPAD CATEGORY 4 Protect the installation against frost (ventilated place in the under terrace confi guration ; frost protection implementation in the buried confi guration). Provide adequate ventilation to disperse the oil vapors and consider that they are a danger zone. 45

48 INSTALLATION INSTRUCTIONS OF A PARALLELIPEDIC DEVICE WITH MANHOLE COVERS P039 Refer to standard NF P for light liquid separators and silt storages and to standard NF EN for grease separators. For handling of the separator, it is essential to lift up the device using the 4 lugs. Check the condition of the lining before lowering the separator into the hole. 1) Carry out the earthwork. 2) Overlap the bottom of the excavation with some thick compacted sand (10 cm minimum) which will be laid perfectly level and put the device in place connecting the pipes and the ventilation system. 3) Installation of the oil level alarm in the oil or grease separator : REMINDER: according to the standard NF EN CE, the oil level alarm is mandatory except if a special derogation has been obtained from local authorities. Before fi lling with water, install a sheath up to the packing box and install the probe as indicated in notice P083 (oil separators) and notice P086 (grease separators).* Be careful : the minimum diameter of the sheath is 80 mm. 4) Fill in symmetrically, in successive layers and with sand to the upper level of the separator. It is necessary to proceed with water fi lling of the separator in order to balance pressures before the banking up operations are started. 5) Lay 10 cm of sand on top of the device. Pour a reinforced concrete slab which must rest on unturned ground and be capable of withstanding the strains imposed on the manhole cover. If cast iron covers are necessary, they must be put into place before the concrete slab dries out so that a perfect water seal is achieved. * For oil separators and as per diagram 1 of notice P083, the sheath passes via the concrete covers and can be put on after its immersion in water. * Anchorage on hydromorphic ground with stowing belts on a reinforced concrete slab (MAXI UPPER LEVEL OF THE GROUNDWATER = WATER ENTRANCE UNIT OF THE DEVICE) In case of sheet groundwater or ground liable to fl ooding, all necessary precautions must be taken such as installing a correctly dimensioned reinforced concrete slab, with some retainer rings for the anchoring straps. It should be protected on the lower side by a pad and covered by a layer of gravel and geotextile on the upper side. 46

49 INSTALLATION INSTRUCTIONS OF A PARALLELIPEDIC DEVICE WITH ADJUSTABLE STEEL EXTENSION SHAFTS P040 In the absence of Special Technical Specifi cations, refer to the Standard NF P For handling of the separator, it is essential to lift up the device using the four lugs. Check the condition of the lining before lowering the separator in the hole. 1) Carry out the earthwork. 2) Overlap the bottom of the excavation with some thick compacted sand (10 cm minimum) which will be laid perfectly level and put the device in place connecting the pipes and the ventilation system. 3) Installation of the oil level alarm in the oil or grease separator : REMINDER: according to standard NF EN CE, the oil level alarm is compulsory except if a special derogation has been obtained from local authorities. Before fi lling with water, install a sheath up to the packing box and install the sensor as indicated in notice P083 (oil separators) and notice P086 (grease separators). Be careful : the minimum diameter of the sheath is 80 mm. 4) Fill in symmetrically, in successive layers and with sand up to the upper level of the separator. It is necessary to proceed with water fi lling of the separator in order to balance pressures before the banking up operations are started. 5) Pour a reinforced concrete slab which must rest unturned ground and be capable of withstanding the strains imposed on the manhole covers. After opening the manhole covers, apply (from the inside of the extension shaft), a joint putty-glue polyurethane of type PU 40 in the pump around the steel extension shafts in order to guarantee the sealing between the rectangular manhole cover and the extension shaft. * Anchorage on hydromorphic ground with strowing belts on a reinforced concrete slab (MAXI UPPER LEVEL OF THE GROUNDWATER = WATER ENTRANCE LINE OF THE DEVICE) In case of sheet groundwater (groundwater, waterlogging, clay soils,...), all necessary precautions must be taken such as installing a correctly dimensioned reinforced concrete slab, with some retainer rings for anchoring straps. Fitting of a piezometer with a minimum diameter of 315 mm is recommended. It should be portected on the lower side by a pad and covered by a layer of gravel and geotextile on the upper side. 47

50 INSTALLATION INSTRUCTIONS PRE-TREATMENT DEVICES POLYETHYLENE RANGE FOR OIL SEPARATORS P041 Stabilized ground - dry ground - ground with no water table The device must be buried as close as possible to the place to be treated and outside a building. The cover must reach the natural ground level. 1) Carry out the earthwork and overlap the bottom of the excavation with some thick compacted sand (10 cm minimum) which will be led perfectly level. 2) Put the device in place connecting the levels of the pipes. 3) Backfi ll with sand and fi ll the device with water. Before fi lling with water, install a sheath up to the packing box and install the sensor as indicated in notice P083 (oil separators) and notice P086 (grease separators). Be careful : the minimum diameter of the sheath is 80 mm. 4) Vent pipes must be connected with a recommended diameter of 100 mm and will be capped with a device to prevent the passage of small animals. 5) Finish backfi lling up to the cover with sand or topsoil. A slab protection resting on undisturbed ground is necessary in the following cases : - If the inlet level from the ground level is above 50 cm. - In vehicles will drive over the area less than 3 meters away. - In case of cast iron covers. Note: Put in place extension shafts to let access to the device. INSTALLATION WITH POLYETHYLENE RECTANGULAR FRAME (TOTAL ACCESSIBILITY) INSTALLATION WITH POLYETHYLENE MANHOLE COVER (CAST IRON COVER) 48

51 INSTALLATION INSTRUCTIONS OIL SEPARATORS POLYETHYLENE TANK TO BE BURIED TECHNICAL SHEETS 6647 AND 6648 P060 Terracing Beware : the altimetric positioning of the tank height must be calculated in such a way that the level of the ground water is not above that of the water outlet level. Dig a separate hole for each tank and if necessary, push down the ground water until after backfi lling work for the device has been carried out. The walls must allow a space of about 70 cm around the tank. The bottom of the sloping which creates a barricade of earth must be at least 4 m around the tank. Handling The tanks must be handled using chain slings to hang on the hoist rings on top of the ring-like and with the hoist (not lift with forks) adapted to the volume of the tank. Chain slings must be provided by the installation company. Expect the accessibility of transport suitable for location (tractor-trailers). Making a slab protection made of heavily reinforced concrete 1) If there is backfi ll in excess of 60 cm above the tank s upper cone. 2) In the presence of groundwater 3) If there is occasional overload due to vehicles driving less than 4 m away from the edge of the hole. 4) If extension shafts in concrete are to be used. 5) If there are overloads due to extreme climatic conditions. This slab must rest on stable ground which must be non-turned. Beware : Before completion of the concrete slab, the tank must be completely fi lled. Anchoring strap It is important to use straps CA3/FX15 when they will be fi xated around the tank and on the irons, they should not be unduly strained to prevent ovalization of the tank. Special Cases In the case of implantation in unstable ground and/or silt ground, it is necessary to make the lateral embankment using stabilized sand 200 kg/ m3. INSTALLATION ON A NON-HYDROMORPHOUS, NON-CLAY SOILS, SILT GROUND OR GROUND WITH NO WATER TABLE INSTALLATION ON A HYDROMORPHOUS, NON-CLAY SOILS, SILT GROUND MAXIMUM HEIGHT GROUNDWATER = WATER OUTLET LEVEL 49

52 INSTALLATION INSTRUCTIONS GROUND WITH A WATER TABLE FOR PE SEPARATOR TECHNICAL SHEETS : 6645 AND 6649 P072 P /06/27 TERRACING : INSTALLATION ON NON-HYDROMORPHOUS, NON-CLAY SOILS OR GROUND WITH NO WATER TABLE INSTALLATION ON A STABILIZED HYDROMORPHOUS GROUND OR CLAY SOILS MAXIMUM HEIGHT GROUNDWATER = WATER OUTLET LEVEL upper backfi ll Geotextile Lateral backfi ll made of sand, accumulation and tank water fi lling by layers of 50 cm Sand setting bed thickness 10 cm Invert Beware : The altimetric positioning of the tank must be calculated in such a way the height of the ground water is not above the water outlet level. Dig a separate hole for each tank and if necessary push down the ground water until after backfi lling work for the device has been carried out. The walls must allow a space of about 30 cm around the tank and must be covered with geotextile. The bottom of the sloping which creates a barricade of earth must be at least 4 m aound the tank. The lateral backfi lling made of sand must be carried out at the same time as the water fi lling of all the compartments. Start the water fi lling with the outlet compartment. Making a slab protection made of heavily reinforced concrete : 1) In case of device with primer manholes. 2) In case of backfi ll in excess of 50 cm above the inlet level. 3) In case of occasional overload due to vehicles driving less than 4 m away from the edge of the hole. 4) If concrete extension shafts are to be used. 5) If there are overloads due to extreme climatic conditions. This slab protection made of heavily reinforced concrete must rest on stable and non-turned ground all around the hole. Beware, before completion of the concrete slab, the tank must be completely fi lled. Special cases : In case of implementation in unstable ground and/or silt ground, it is necessary to make the lateral embankment using stabilized sand 200 kg/m 3 In case of fi ssured grounds, a geotextile must be installed on all the excavation. 50

53 INSTALLATION INSTRUCTIONS GROUND WITH A WATER TABLE FOR PE SEPARATOR TECHNICAL SHEETS : 6645 AND 6649 P /06/27 P072 P /06/27 HANDLING : During unloading and installation, the separator must be handled with the handling straps. A lifting bar must be used between the slings so that the lifting efforts are vertical. - Chain slings and a lifting bar must be provided by the installation company. - Provide accessibility to transport which will be suitable with the nature of the site (possible accessibility of the tractor-trailers). HYDRAULIC CONNECTION : The inlet and outlet of the separator are identifi ed by inscriptions. The separateur has conical inlet and outlet, the connection with the pipes is made easily by fi tting (no joint). STRAPS : In case of ground with a water table, it is necessary to strap the tank on an invert. The invert weight will be calculated in order to limit the buoyancy when the device is empty. Concrete iron (not supplied) Invert Straps Sand setting bed 10 cm Straps example separator NS15 NOTA : For the devices with a central strength (example: NS15), the straps would not have constraints on this strength (see photo above). AERATION AND CABLE RUN : For the interveners security, we recommend to install the aeration via the diameter 100 located on the side of the device. The cable passage for the oil and sludge sensor must be done via the diameter 50 located on the other side of the device. Cable Passage Inlet Outlet Aeration 51

54 INSTALLATION INSTRUCTIONS ALARMS ANH22/14320 AND ANH22/15200 FOR OIL SEPARATOR STEEL APHA P083 Works to be done If the separator is equipped with manhole, put a mark on the sensor cable as described below and pass the cable through the sheath, put in place by the installation company. Attach the cable with the clip to the guiding tube of the shutter so that the mark is positioned at the water level in the separator (1). Serflex collar H The Serfl ex collar is used as a mark at the static water level. It will be positioned at this level. To be positioned again at this level during the cleaning of the sensor. Electrical connections > see instructions supplied with the alarm. Device Reference NS Height H Device Reference NS Height H Device Reference NS Height H Device Reference NS Height H

55 INSTALLATION INSTRUCTIONS ALARMS ANH22/14320 AND ANH22/15200 FOR OIL SEPARATORS POLYETHYLENE APHP P084 The Serfl ex collar is used as a mark at the static water level. It will be positioned at this level. To be positioned again at this level during the cleaning of the sensor. Serflex collar H Work to be done Install the sensor into the separator. Use the collar installed on the sensor cable to put a mark on the H spot height (you will fi nd this spot height in the table below according the reference of the oil separator). Attach the cable with the clip to the guiding tube of the shutter so that the mark is positioned at the water level in the separator. Electrical connections > see instructions supplied with the alarm. Device reference NS Height H Device Reference NS Height H

56 GENERAL MAINTENANCE INSTRUCTIONS PE OIL SEPARATORS < 30 l/s E101 Silt storage compartment The silt storage, located at the device inlet, must be drained at least once a year, when the sludge level reaches 50% of the storage capacity or after the sludge alarm has been activated. Separator compartment This compartment is composed by : - An oil storage compartment : oils are trapped on the surface. - A rotproof coaslescence cell which accelerates the separation of the oils with a density inferior to the water density. - An automatic shutter system. This compartment must be drained at least once a year or as soon as the thickness of the light liquid layer reaches 150 mm to 200 mm or when the oil alarm triggers. Reminder : The oil level is mandatory as additional piece of equipment unless special derogation from the local authorities. The rotproof coalescence cells in this compartment must be cleaned after each draining and at least once a year. Separator type SH2/6645 Separator type SH2/

57 GENERAL MAINTENANCE INSTRUCTIONS PE OIL SEPARATORS < 30 l/s E101 Maintenance (cf NF P16-442) The system maintenance must be carried out at least every six months by qualifi ed staff. The maintenance consists of : - Measure the sludge and light liquids volume - Check the proper functioning of the shutter device - Check the proper functioning of the alarm device - Control the coalescence cells Every 5 years, the device must be drained to check : - The device sealing - The structural condition - The internal equipments - The shutter adjustment - The alarm device During the drainings, it is necessary to : - check the nozzle of the aspiration pipe does not damage the interior of the separator. - Pump the cleaning residues trapped in the bottom of the device. - Clean the coalescence cells (see indications paragraph «Maintenance of the coalescence») - Clean the shutter system (see indications paragraph «Maintenance of the shutter system»). - Remove all the residues respecting the prescriptions of the competent authorities. Before and during the water fi lling of the device, lift the shutter at least about 20 cm. Security rules Before any human intervention inside the device : - Ensure the owner of the site knows about your intervention. - Do not smoke. - If the collecting network is equipped by valves, close these ones located at the inlet and outlet of the device. - Open all the frames to ventilate the device. - Wear a gas mask or be sure there is no toxic gas (Ex : H 2 S) thanks to a detector. - Lighting : only use 24 volts et explosion protected equipment. - Go into the device bewaring of not slide on the oil residues there would be on the tank walls. Never intervene alone. Regulations and decrees concerning accident prevention and the handling of hazardous materials must be respected. 55

58 GENERAL MAINTENANCE INSTRUCTIONS PE OIL SEPARATORS < 30 l/s E101 Maintenance of the coalescence The rotproof coaslescence cells in the separator compartment must be cleaned after each draining and at least once a year. After draining the device, a small quantity of suspended matter could however stay in the coalescence material. For the devices type SH2/6647 and SH2/6648, the procedure is as follows : 1/ Remove the layers of coaslescence foam and rince them. 2/ Rince the coalescence cells in the bottom of the coalescence thanks to a water jet. 3/ Replace the layers of coalescence foam. 4/ Replace the coalescence system. 1/ Remove the coalescence system 3/ Coalescence cells 5/ Coalescence system 56

59 GENERAL MAINTENANCE INSTRUCTIONS PE OIL SEPARATORS < 30 l/s E101 Maintenance of the coalescence The separator compartment is equipped by rotproof coaslescence cells which must be cleaned after each draining and at least once a year. After draining the device, a small quantity of suspended matter could however stay in the coalescence material. For the devices type SH2/6647 and SH2/6648, the procedure is as follows : Admission pipe 1 Silt storage Coalescence compartment Shutter compartment Shutter - Remove the coalescence system thanks to the stainless steel cane and rince it with a water jet. - Also remove the net full of coaslescence matters from the coalescence compartment and rince it. - Drain the effl uent which will rest in the shutter and coalescence compartments. - Check the grid located on the admission pipe is not damaged. Maintenance of the shutter system Shutter After each draining and at least once a year we highly recommend : - Clean the shutter - Remove the matter which could lay on the shutter joint and on the shutter blank to make sure shutter is working properly. - Check the shutter joint and replace it if necessary. Shutter joint 57

60 GENERAL MAINTENANCE INSTRUCTIONS PE OIL SEPARATORS < 30 l/s Device reference :... Commissioning :... Intervention date Drained volume Observation Signature 58

61 Notes

62 Notes 60

63 Notes 61

64 IS ALSO : 10 rue Richedoux SAINTE-MÈRE-ÉGLISE FRANCE Tél. +33 (0) Fax +33 (0) simop@simop.fr Rainwater Treatment Rainwater recovery Oil Separators Particulate decanters Basin Facilities S.A.S. CAPITAL euros SIRET Wastewater Treatment Wastewater treatment < 20 PE Wastewater treatment > 20 PE Grease separators Roads & Networks Soil Products Road Equipment Sanitation manholes Pumping stations Find all our products on Mise en pages Quai des Graph Juillet 2012.

Fuel and Oil Separators

Fuel and Oil Separators Fuel and Oil Separators PREMIERTECHAQUA.CO.UK Premier Tech Aqua UK s range of Conder Fuel and Oil Separators are for use with surface water drainage systems and are designed to prevent hydrocarbons (e.g.

More information

THE PARTNER OF CHOICE. Conder Separator Brochure_8 pages_pta 2015.indd 1

THE PARTNER OF CHOICE. Conder Separator Brochure_8 pages_pta 2015.indd 1 OIL/WATER SEPARATORS S T O R M WAT E R THE PARTNER OF CHOICE Conder Separator Brochure_8 pages_pta 2015.indd 1 15/09/2016 11:16 Premier Tech Aqua s range of Conder Oil Separators are for installation on

More information

HYDROCARBON SEPARATORS

HYDROCARBON SEPARATORS HYDROCARBON SEPARATORS Hydrocarbon separators class I in PE Standard version (to install in consolidated sand) Reinforced version (to install in sand) Without and with mud trap Hydrocarbon separators class

More information

CONTENT OIL/WATER SEPARATOR TANKS FOR ALL INDUSTRIES FIBREGLASS. 1. General Information. 2. Important features. 3. Areas of applications

CONTENT OIL/WATER SEPARATOR TANKS FOR ALL INDUSTRIES FIBREGLASS. 1. General Information. 2. Important features. 3. Areas of applications FIBREGLASS OIL/WATER SEPARATOR TANKS FOR ALL INDUSTRIES CONTENT 1. General Information 2. Important features 3. Areas of applications 4. Principle of oil separator 5. Choice of oil/water separator 6. Sizing

More information

Separators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation

Separators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation he new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation ACO Grease, starch and light liquid separators for below ground installation Commercial operations

More information

OWS OPERATIONS & MAINTENANCE

OWS OPERATIONS & MAINTENANCE SUPPLEMENTAL INSTRUCTIONS 1. INTRODUCTION 1.1. Containment Solutions manufactures Oil/Water Separator (OWS) tanks with internal coalescing plates. These units are available in single or double-wall model

More information

Separators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation

Separators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation he new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation ACO Grease, starch and light liquid separators for below ground installation Commercial operations

More information

Marsh Industries. Marsh Hydroil: Oil separators

Marsh Industries. Marsh Hydroil: Oil separators Marsh Industries Marsh Hydroil: Oil separators Bypass separators Full retention separators Forecourt separators Wash-down separators and silt traps Alarm systems www.marshindustries.co.uk 2 WE are the

More information

OVERVIEW OPERATION. 2 Stormceptor EF Technical Manual

OVERVIEW OPERATION. 2 Stormceptor EF Technical Manual EF Technical Manual OVERVIEW Stormceptor EF is a continuation and evolution of the most globally recognized oil-grit separator (OGS) stormwater treatment technology - Stormceptor. Also known as a hydrodynamic

More information

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual For Single-Wall and Double-Wall Fibreglass Underground Storage Tanks This Aquator Commercial Oil Water Separator (OWS)

More information

B2. Fueling Operations

B2. Fueling Operations B2. Fueling Operations Commercial / Industrial / Institutional & Municipal Pollution Prevention Goal: Prevent or reduce the risk of discharge of pollutants to stormwater from vehicle and equipment fueling

More information

SOCIETY OF PUBLIC HEALTH ENGINEERS

SOCIETY OF PUBLIC HEALTH ENGINEERS SOCIETY OF PUBLIC HEALTH ENGINEERS TECHNICAL WORKSHOP LIGHT LIQUID SEPARATORS Wednesday 28 April 2004 Agenda: Introduction Definition Separator (Interceptor) Separators Types Classes Full Retention Separators

More information

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual This Aquator Commercial Oil Water Separator (OWS) Operating and Maintenance Manual gives instructions for single-wall

More information

Regular inspections are recommended to ensure that the system is functioning as designed.

Regular inspections are recommended to ensure that the system is functioning as designed. SiteSaver Manufacturer s Instruction Manual Regular inspections are recommended to ensure that the system is functioning as designed. Please contact your Authorized SiteSaver Representative if you have

More information

CATALOGUE SEWAGE MANHOLES

CATALOGUE SEWAGE MANHOLES CATALOGUE SC SEWAGE MANHOLES Table of contents TABLE OF CONTENTS Introduction 4 Inspection chamber, type 315 7 Inspection chamber, type 400 10 Inspection chamber, type 425 14 Assembly instruction 19 Catch

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance

More information

Salesfolder Light fluid and EN grease separator Light fluid and grease separator

Salesfolder Light fluid and EN grease separator Light fluid and grease separator Salesfolder Light fluid and EN grease separator 950440 35 Light fluid and grease separator Light fluid separator Separator systems for light fluid liquids class I + II Separators are needed wherever water

More information

Vehicle and Equipment Fueling

Vehicle and Equipment Fueling Vehicle and Equipment Fueling SC-20 Objectives Cover Contain Educate Reduce/Minimize Description Spills and leaks that occur during vehicle and equipment fueling can contribute hydrocarbons, oil and grease,

More information

ABCD BFDC BEDA AB CDEFCC

ABCD BFDC BEDA AB CDEFCC ABCD BFDC BEDA AB CDEFCC ABCD BFDC BEDA AB CDEFCC AFC Oil/ Water Separator Specifications and Operation & Maintenance Schedule 1) Model of AFC Oil/ Water Separator: a)

More information

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version SEPTIC TANKS Round septic tanks Standard version ECO version Rectangular septic tanks Standard version ECO version Reinforced vertical septic tanks Reinforced horizontal septic tanks Grease traps for private

More information

AutoDose Automatic Dispensing System

AutoDose Automatic Dispensing System AutoDose Automatic Dispensing System The AutoDose TM is a battery or A/C-powered peristaltic pumping dispenser that runs automatically at preset times as programmed with an electronic timer / control.

More information

Solutions in Rail Heating Systems. Rail Heating Proposal. Innovations in heat tracing

Solutions in Rail Heating Systems. Rail Heating Proposal. Innovations in heat tracing Solutions in Rail Heating Systems Rail Heating Proposal Innovations in heat tracing Innovations in heat tracing eltherm our company How can we protect antennas from ice in frosty weather? How can we transport

More information

The Up-Flo Filter Stormwater Treatment System Operation and Maintenance Manual UP-FLO FILTER OPERATION AND MAINTENANCE MANUAL Table of Contents 3 Up-Flo Filter - Overview - General Product Description

More information

Separators. industrieblick Fotolia.com. For indoor or below ground installation ACO Light Oil Separators Coalisator-P

Separators. industrieblick Fotolia.com. For indoor or below ground installation ACO Light Oil Separators Coalisator-P Separators industrieblick Fotolia.com For indoor or below ground installation ACO Light Oil Separators Coalisator-P Light Oil Separators Application If mineral oils or light oils, especially those that

More information

Grease Inspection Program

Grease Inspection Program Grease Inspection Program Dublin San Ramon Services District (DSRSD) must comply with federal and state pretreatment regulations. The Publicly Owned Treatment Work s (POTWs) are charged with enforcing

More information

LA CONNER MARINA MANDATORY BEST MANAGEMENT PRACTICES

LA CONNER MARINA MANDATORY BEST MANAGEMENT PRACTICES LA CONNER MARINA MANDATORY BEST MANAGEMENT PRACTICES The following mandatory BMPs will be implemented at the La Conner Marina, per the Boatyard General Permit (effective June 1, 2011), issued by the Department

More information

CITY OF AVON PARK Highlands County, Florida Office of the City Manager 110 East Main Street Avon Park, Florida 33825

CITY OF AVON PARK Highlands County, Florida Office of the City Manager 110 East Main Street Avon Park, Florida 33825 CITY OF AVON PARK Highlands County, Florida Office of the City Manager 110 East Main Street Avon Park, Florida 33825 JOINT WORKSHOP AVON PARK CITY COUNCIL & PLANNING AND ZONING BOARD CITY COUNCIL CHAMBERS

More information

ACO product catalogue ACO GRP (Glass Reinforced Plastic) Separators Grease & Light Oil Separators Sludge Trap

ACO product catalogue ACO GRP (Glass Reinforced Plastic) Separators Grease & Light Oil Separators Sludge Trap ACO product catalogue ACO GRP (Glass Reinforced Plastic) Separators Grease & Light Oil Separators Sludge Trap ACO. The future of drainage GRP (Glass Reinforced Plastic) Separators Grease & Light Oil Separators

More information

Oil Water Separators Product Range

Oil Water Separators Product Range Industrial Water Treatment and Recycling Specialists Oil Water Separators Product Range 1800 353 788 www.cleanawater.com.au Oil Separators Total Range Cleanawater provide the largest range of oil water

More information

BROCHURE Water pre-treatment. Oil. and. grease separators

BROCHURE Water pre-treatment. Oil. and. grease separators BROCUR 2 0 1 1 Water pre-treatment Oil and grease separators resentation...4 ow to choose?...6 Introduction...7 ow to choose them?...8 OYTYN 05 and DF, with sludge trap & coalescing filter...10 10 and

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass JR12/JR23 L731 CI/SfB (52.7) ACO Q-Brake Vortex Vortex flow controls ACO Q-Brake Vortex Introduction to the ACO Group Throughout the world, the ACO

More information

Gullies. Box - Gutters. Slot - Gutters. Grease Locks

Gullies. Box - Gutters. Slot - Gutters. Grease Locks Gullies Box - Gutters Slot - Gutters Grease Locks 1 for Food Processing Specifically tailored waste water systems Box Gutters Stainless steel 1.4301. These time-tested models are available in two widths

More information

Stormwater Treatment System

Stormwater Treatment System The Up-Flo Filter Stormwater Treatment System Table of Contents 3 Up-Flo Filter - Overview - General Product Description - Typical Configurations - Maintenance Services 4 Operation - Introduction - Pollutant

More information

Dewatering Submersible sewage pumps

Dewatering Submersible sewage pumps Series description Wilo-Drain TP 80/TP 100 Equipment/function Thermal motor monitoring Leakage detection in the motor ATEX-certified Sheath current cooling Materials Pump housing: PUR Impeller: PUR Shaft:

More information

ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator Bypass G

ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator Bypass G ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator Bypass G ACO. The future of drainage Glass Fibre Light Oil Separators Oleopator Bypass G collect: Collect and remove clean: Pre-clean and

More information

Petrol & Oil Interceptor

Petrol & Oil Interceptor Petrol & Oil Interceptor VP10AG > above-ground installation. > usually associated with automotive workshops such as a garage, carwash, & etc. and also referred to as a Triple Interceptor. > this tank design

More information

ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator G

ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator G ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator G ACO. The future of drainage Glass Fibre Light Oil Separators Oleopator G collect: Collect and remove clean: Pre-clean and process hold:

More information

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve CSO/STORMWATER MANAGEMENT HYDROVEX CCV Check Valve HYDROVEX CCV CIRCULAR CHECK VALVE APPLICATION The HYDROVEX CCV Check Valve is designed for use in water and sewage. It has no reinforcement and is especially

More information

1) Activity Description: Management of Petroleum Storage Tanks and Containers

1) Activity Description: Management of Petroleum Storage Tanks and Containers ES-301-4.09 Management of Petroleum Storage Tanks and Containers Document Identification Number ES-301-4.09 Document Owner: John Hambright 1) Activity Description: Management of Petroleum Storage Tanks

More information

first flust water diverters water quality first downpipe, post/wall mounted and in-ground diverters

first flust water diverters water quality first downpipe, post/wall mounted and in-ground diverters water quality first downpipe, post/wall mounted and in-ground diverters Available in kit form just add PVC pipe Simple, effective and easy to install Includes Slow Release Control Valve - empties after

More information

December Labko BioKem Wastewater Treatment Plants. Product brochure BATCH REACTORS FOR PROCESSING WASTEWATER OF 6-90 PERSONS

December Labko BioKem Wastewater Treatment Plants. Product brochure BATCH REACTORS FOR PROCESSING WASTEWATER OF 6-90 PERSONS December 2006 Labko BioKem Wastewater Treatment Plants Product brochure BATCH REACTORS FOR PROCESSING WASTEWATER OF 6-90 PERSONS Reliable solutions Wastewater treatment systems Labko BioKem Batch Reactors

More information

CSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator

CSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator CSO/STORMWATER MANAGEMENT Hydrovex VHV / SVHV Vertical Vortex Flow Regulator HYDROVEX VHV / SVHV VERTICAL VORTEX FLOW REGULATOR INTRODUCTION One of the major problems of urban wet weather flow management

More information

FORT RUCKER Environmental Management System

FORT RUCKER Environmental Management System Washrack and Oil Water Separator Operations and Maintenance Approved By: Phil Anderson / Melissa Lowlavar 1.0 PURPOSE This procedure defines the requirements for proper operation and maintenance of washracks

More information

ABS lifting station Synconta

ABS lifting station Synconta 15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...

More information

DELPHIN cube. Reliable process Strong tanks Clever modules. Compact biological wastewater treatment plants with fixed-bed technology

DELPHIN cube. Reliable process Strong tanks Clever modules. Compact biological wastewater treatment plants with fixed-bed technology DELPHIN cube Compact biological wastewater treatment plants with fixed-bed technology DELPHIN Water Systems GmbH & Co. KG The experts for fixed-bed technology Modular system for decentralized wastewater

More information

Reliable backwater protection. Protection from backwater. Backwater protection for interior installation

Reliable backwater protection. Protection from backwater. Backwater protection for interior installation Reliable backwater protection Protection from backwater Backwater Protection - things you need to know Prevention Not properly protecting a building against backwater can result in damage that is extremely

More information

OIL & GAS FIELD SYSTEMS

OIL & GAS FIELD SYSTEMS OIL & GAS FIELD SYSTEMS Washing + CONTAINMENT + TREATMENT = ground water protection The Solution is Clear with Riveer SM Engineered Wash Water Recovery Systems OIL & GAS Washing + Containment + Treatment

More information

OWNER S MANUAL GREAT BASIN GREASE INTERCEPTORS

OWNER S MANUAL GREAT BASIN GREASE INTERCEPTORS OWNER S MANUAL GREAT BASIN GREASE INTERCEPTORS GBOM-0116 Congratulations! You are the owner of a Great Basin, the world s best grease interceptor. Please use the information in this manual to make the

More information

TECHNICAL type SE. The polyester concrete drainage channel with 4mm protective edge profi le IMC SE EN

TECHNICAL type SE. The polyester concrete drainage channel with 4mm protective edge profi le IMC SE EN TECNICA type SE The polyester concrete drainage with 4mm protective edge profi le IMC SE 5-5 EN TECNICA SE - SE5 - SE2 - SE3 EN 433 Class D4 - E6 Due to their low weight, high strength, good chemical resistance

More information

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet Pump Station Ama-Porter CK Pump Station Type Series Booklet Legal information/copyright Type Series Booklet Ama-Porter CK Pump Station All rights reserved. The contents provided herein must neither be

More information

Environmental Procedures

Environmental Procedures Airside Operational Instruction TBA Airside Operational Instruction 24 Content 1. Aircraft Washing and Use of Detergent-Cleaning Materials 2. Accidental Fuel, Oil or Chemical Spillages 3. Aircraft De-Icing

More information

Micropulse Transducers Applications

Micropulse Transducers Applications Areas of use in which high reliability and precision are in demand are typical application areas for. As integrated or compact versions with measuring lengths of 25 to 7,620 mm, Micropulse position measuring

More information

RAINWATER HARVESTING SYSTEMS

RAINWATER HARVESTING SYSTEMS BALMORALTANKS RAINWATER HARVESTING SYSTEMS Tank installation and operating manual Contents Tank information 1 Product illustrations 2 Installation: Balmoral HydroStore 4 Installation: Balmoral RWH-ST 5

More information

APPENDIX B FUNCTIONAL DESIGN SPECIFICATIONS (Sequence of Operation)

APPENDIX B FUNCTIONAL DESIGN SPECIFICATIONS (Sequence of Operation) APPENDIX B FUNCTIONAL DESIGN SPECIFICATIONS (Sequence of Operation) B.1 WATER SUPPLY FACILITIES 1. General A. The tag number of the equipment comprise three designations (W10 CM 01), where the three designations

More information

NOVELTY. Platin flat rainwater tank. GRAF s version of the flat tank. Integrated filter. Attractive tank. installation depth Suitable for.

NOVELTY. Platin flat rainwater tank. GRAF s version of the flat tank. Integrated filter. Attractive tank. installation depth Suitable for. Platin flat rainwater tank GRAF s version of the flat tank NOVELTY Integrated filter technology Attractive tank cover Minimal installation depth Suitable for vehicle loading Groundwater stable Edition

More information

Watertreatment. Landbased Farming. Weedfilter. Catvis WATER I NTAKE R ECIRCULATION S YSTEM

Watertreatment. Landbased Farming. Weedfilter. Catvis WATER I NTAKE R ECIRCULATION S YSTEM Weeds Drum Cartridge UV-unit WATER I NTAKE Screen Pump Weed Drum UV-unit Climate control H ATCHERY N URSERY B ROODSTOCK O NGROWING Oxygen reactor Denitrification Control unit R ECIRCULATION S YSTEM Ozonation

More information

A WORLD OF ORANGE TRUCK MASTER YEARBOOK

A WORLD OF ORANGE TRUCK MASTER YEARBOOK A WORLD OF ORANGE TRUCK MASTER YEARBOOK 2019-2020 Truck Master series The liquid ring vacuum pumps designed for vacuum trucks and tankers A WORLD OF ORANGE TRUCK MASTER YEARBOOK 2019-2020 +45 87 50 95

More information

OPERATIONS AND MAINTENANCE PLAN

OPERATIONS AND MAINTENANCE PLAN OPERATIONS AND MAINTENANCE PLAN FOR LAKES HIGHWAY DISTRICT PREPARED BY: LAKES HIGHWAY DISTRICT ERIC W. SHANLEY, P.E. DISTRICT ENGINEER Table of Contents Executive Summary... 4 Identification... 4 Scope...

More information

The new rotomoulded tank system ACO Grease and light liquid separators for below ground installation

The new rotomoulded tank system ACO Grease and light liquid separators for below ground installation he new rotomoulded tank system ACO Grease and light liquid separators for below ground installation ACO Light liquid separator Oleopator P Class I Light liquid separator of polyethylene for below ground

More information

The Pump Matic Range

The Pump Matic Range The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality

More information

Sewerage Services.

Sewerage Services. Sewerage Services jballosewage@gmail.com www.jballosewage.com JB ALLO SEWAGE The experience you need and quality you deserve Pumping Services Grease Trap Sump Pit Lift Station Septic Tank Sewage Tank Holding

More information

Typical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application

Typical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application Typical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application Mohr Separations Research Model MSR-33 S Separator Customer: Background

More information

GRAF EcoBloc Stormwater Management System

GRAF EcoBloc Stormwater Management System GRAF EcoBloc Stormwater Management System Scan for more information Technical Guide D9.4 High performance system for managing rain water infiltration, stormwater attenuation and rain water harvesting.

More information

Automotive Service Service Stations

Automotive Service Service Stations Description This category includes facilities that provide vehicle fueling services, including self-serve facilities as well as those that provide a convenience store. Information specific to auto dismantling,

More information

GRAF EcoBloc Stormwater Management System

GRAF EcoBloc Stormwater Management System GRAF EcoBloc Stormwater Management System Scan for more information Technical Guide EVS 21 High performance system for managing rain water infiltration, stormwater attenuation and rain water harvesting.

More information

ENGINEERING AND EQUIPMENT FOR IRRIGATION

ENGINEERING AND EQUIPMENT FOR IRRIGATION M a d e i n F r a n c e ENGINEERING AND EQUIPMENT FOR IRRIGATION 50 years of French experience and innovation Center pivot specialist since 1965: first European manufacturer Pionnier of the hippodrome

More information

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet Automatic Waste Water Pump Station Evamatic-Box N Type Series Booklet Legal information/copyright Type Series Booklet Evamatic-Box N All rights reserved. The contents provided herein must neither be distributed,

More information

HAWLE-AIR RELEASE VALVES

HAWLE-AIR RELEASE VALVES HAWLE-AIR RELEASE VALVES HAWLE-AIR RELEASE VALVES Contents: Dimensions of Air Release Valve Page 2 Why use Air Release Valves? Page 3 Application: Potable water Air Release Valves, DN 1" - DN 2" Page 4

More information

Inclined plate settlers

Inclined plate settlers IPS Inclined plate settlers Compact thickening and clarification, reduced retention time IPS Inclined plate settlers Metso s inclined plate pack principle uses several parallel inclined plates to maximise

More information

City of Tega Cay, South Carolina

City of Tega Cay, South Carolina Fats, Oil and Grease (FOG) Best Management Practices (BMP s) HOW GREASE TRAPS AND INTERCEPTORS WORK Every business that disposes of FOG (restaurants, grocery stores, meat markets, hotels, factory and office

More information

First Defense. Stormwater Treatment System. Operation and Maintenance Manual

First Defense. Stormwater Treatment System. Operation and Maintenance Manual First Defense Stormwater Treatment System Operation and Maintenance Manual First defense OPERATION AND MAINTENANCE Table of Contents 3 First Defense by Hydro International - Benefits of the First Defense

More information

Series 95/96 upvc Valves

Series 95/96 upvc Valves Series 95/96 upvc Valves Product Catalogue Series 96/95 Valves Series 96/95 upvc Valves Catalogue Plastic Valves Dorot Control Valves is a world leader in the development and supply of sustainable technologies

More information

all pump solutions Pumps & packaged pumpstations

all pump solutions Pumps & packaged pumpstations all pump solutions Pumps & packaged pumpstations all pump solutions cater for a wide range of applications involving pumpstations and pumping systems Packaged pumpstations Today s fast-track building methods

More information

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover www.cranepumps.com Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover Specifications: inches (mm) BASIN...Fiberglass w/ 3 (76)

More information

ST. VINCENT AND THE GRENADINES

ST. VINCENT AND THE GRENADINES ST. VINCENT AND THE GRENADINES MARITIME ADMINISTRATION CIRCULAR N POL 012 AMENDMENTS OF THE SUPPLEMENT (FORM A AND B) OF THE IOPP CERTIFICATE TO: SHIPOWNERS, SHIPS OPERATORS AND MANAGERS, MASTERS, RECOGNIZED

More information

Hampton Roads Planning District Commission

Hampton Roads Planning District Commission Hampton Roads Planning District Commission OBJECTIVE To help Grease Haulers comply with the Regional Consent Order and ensure proper maintenance of grease control devices. BACKGROUND In 2007, Special Orders

More information

DIAPHRAGM PUMPS: Instruction Manual

DIAPHRAGM PUMPS: Instruction Manual INTRODUCTION DIAPHRAGM PUMPS: Instruction Manual Congratulations for choosing a product Imovilli Pompe, the result of a careful manufacturing process supported by over fifty years of specific experience

More information

ACO Light liquid separator Oleopator P Class I. Oleopator P Order data. Light liquid separators

ACO Light liquid separator Oleopator P Class I. Oleopator P Order data. Light liquid separators Light liquid separators ACO Light liquid separator Oleopator P Class I Light liquid separator of polyethylene for below ground installation according to EN 858 certificate 7310434-01 () 7310434-02 () 7310434-03

More information

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC 62/24/Add.1 Annex 24, page 1 ANNEX 24 RESOLUTION MEPC.205(62) 2011 GUIDELINES AND SPECIFICATIONS FOR ADD-ON

More information

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD. Technical Data DML Submersible Sewage s with Single Channel Impeller AUSTRALIA PTY. LTD. DML_Techdata_SS_V Contents -SPECIFICATIONS FEATURES & APPLICATIONS TYPICAL EXPLODED VIEW SPECIFICATIONS SELECTION

More information

AMERICAN RECIRCULATING SAND FILTER SYSTEMS

AMERICAN RECIRCULATING SAND FILTER SYSTEMS American Manufacturing Company, Inc. P.O. Box 549, Manassas, VA 20108 1-800-345-3132 AMERICAN RECIRCULATING SAND FILTER SYSTEMS ENGINEERING DESIGN GUIDELINES FOR COMMUNITY AND COMMERCIAL SIZED TREATMENT

More information

SPECIAL WASTE CONTAINER TYPE SAF

SPECIAL WASTE CONTAINER TYPE SAF SPECIAL WASTE CONTAINER TYPE SAF 450-1000 litres for the international transport of hazardous liquids according to the ADR/ RID/IMDG codes, packing groups II and III SPECIAL WASTE CONTAINER according to

More information

ACO Drain. For more information on ACO Drain visit ACO KerbDrain 280 Splay

ACO Drain. For more information on ACO Drain visit  ACO KerbDrain 280 Splay Uniclass L223 + L735 EPIC J343 ACO Drain ACO KerbDrain Splay CI/SfB (52.5) ACO KerbDrain Splay Kompact combined drainage and kerb system ACO KerbDrain Splay Product Overview Introduction to ACO KerbDrain

More information

ACO product catalogue ACO GRP Sludge Trap G-H

ACO product catalogue ACO GRP Sludge Trap G-H ACO product catalogue ACO GRP Sludge Trap G-H ACO. The future of drainage Glass Fibre Sludge Trap G-H collect: Collect and remove clean: Pre-clean and process hold: Protect and attenuate release: Pump,

More information

ANNEX 23. RESOLUTION MEPC.187(59) Adopted on 17 July 2009

ANNEX 23. RESOLUTION MEPC.187(59) Adopted on 17 July 2009 RESOLUTION MEPC.187(59) Adopted on 17 July 2009 AMENDMENTS TO THE ANNEX OF THE PROTOCOL OF 1978 RELATING TO THE INTERNATIONAL CONVENTION FOR THE PREVENTION OF POLLUTION FROM SHIPS, 1973 (Amendments to

More information

Domestic Traditional Pits DOMESTIC TRADITONAL PITS

Domestic Traditional Pits DOMESTIC TRADITONAL PITS Domestic Traditional Pits Ideal for use under downpipes, as a junction box, or at the end of a surfacewater drainage channels Designed for large household surfacewater drainage Australian Made from 100%

More information

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District Last Updated on October 27, 2011 Grease interceptors are required to separate out Fats, Oils and Greases (FOGs) and solids normally found in food preparation waste from the rest of the wastewater being

More information

Pretreatment Programs Fats, Oils and Grease FRWA Daytona 2015

Pretreatment Programs Fats, Oils and Grease FRWA Daytona 2015 Pretreatment Programs Fats, Oils and Grease FRWA Daytona 2015 Why Be Concerned About FOG? The majority of dry weather SSOs are caused by grease Grease accumulates in pump station wet wells and can cause

More information

Chapter 12 SERVICING

Chapter 12 SERVICING Chapter 12 SERVICING 12-Title Page 1 January 23, 2012 INTENTIONALLY LEFT BLANK 12-Title Page 2 January 23, 2012 LIST OF EFFECTIVE PAGES Chapter Section Page No. Date 12 12-Title 1 January 23, 2012 2 January

More information

GRAF OIL&GAS IS A GRAF GROUP DIVISION, TWENTY-YEARS EXPERIENCED IN OIL&GAS MARKET.

GRAF OIL&GAS IS A GRAF GROUP DIVISION, TWENTY-YEARS EXPERIENCED IN OIL&GAS MARKET. GRAF OIL&GAS IS A GRAF GROUP DIVISION, TWENTY-YEARS EXPERIENCED IN OIL&GAS MARKET. Thanks to its experience, GRAF SPA is able to provide turnkey station from engineering up to planned maintenance and aftersales

More information

RAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application

RAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application RAINWATER HARVESTING INSTALLATION GUIDE RH9521-12 High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application RH9521-12 Vortex Filter Operation and Maintenance Overview The RH9521-12

More information

Flygt TOP 65, 100 and 150. Turnkey pump stations

Flygt TOP 65, 100 and 150. Turnkey pump stations Flygt TOP 65, 100 and 150 Turnkey pump stations TOP choice for reliability, safety and efficiency Pre-assembled turnkey solutions Xylem offers turnkey wastewater pump station solutions to meet your requirements

More information

Spillage from a semi-buried jet fuel tank 30 December, 2005 Sainte-Marie [Reunion Island] France

Spillage from a semi-buried jet fuel tank 30 December, 2005 Sainte-Marie [Reunion Island] France Spillage from a semi-buried jet fuel tank 30 December, 2005 Sainte-Marie [Reunion Island] France Spillage Flammable liquid farms Valves Jet fuel Human and organisational factor Soil contamination Level

More information

SASKATCHEWAN AMENDMENTS TO APPENDICES OF THE NATIONAL PLUMBING CODE, 2005

SASKATCHEWAN AMENDMENTS TO APPENDICES OF THE NATIONAL PLUMBING CODE, 2005 SASKATCHEWAN AMENDMENTS TO APPENDICES OF THE NATIONAL PLUMBING CODE, 2005 This section contains Saskatchewan Amendments to the diagrams and explanations in the Appendices of the National Plumbing Code,

More information

Installation, Operations & Maintenance

Installation, Operations & Maintenance Cleanawater TS2000 SS Oil Water Separator 2000 L/hr Installation, Operations & Maintenance 1800 353 788 info@cleanawater.com.au cleanawater.com.au TABLE OF CONTENTS COMPANY INFORMATION 2 PARTS INCLUSION

More information

GREASE INTERCEPTOR REQUIREMENTS

GREASE INTERCEPTOR REQUIREMENTS CALAVERAS COUNTY WATER DISTRICT GREASE INTERCEPTOR REQUIREMENTS HANDOUT 05 Calaveras County Water District Water and Sewer Building Service Standards GREASE INTERCEPTOR REQUIREMENTS GENERAL The following

More information

Introducing the world's most reliable solar panel. Company presentation / Solar panels

Introducing the world's most reliable solar panel. Company presentation / Solar panels Introducing the world's most reliable solar panel Company presentation / Solar panels Senersun Identity Quality in Senersun DNA Senersun is the manufacturer of the world s most reliable solar panel. Simple

More information

RELN Septic & Holding Tanks

RELN Septic & Holding Tanks RELN Septic & Holding Tanks New, Improved Tanks RELN s complete range of purpose designed black water tanks take quality and flexibility to the next level, with: Unique stepped ribs for greater strength

More information

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines 000535 GL0098P Beta+ Septic Tanks Installation & Operation Guidelines Kingspan Environmental Service Contact Numbers: UK: 0844 846 0500 NI: 028 3025 4077 IRL: 048 3025 4077 Enclosed Documents DS1151P Beta+

More information

Aircraft Wash Plan. For Airport Tenants and Users at Nashua Airport Boire Field

Aircraft Wash Plan. For Airport Tenants and Users at Nashua Airport Boire Field Aircraft Wash Plan For Airport Tenants and Users at Nashua Airport Boire Field NOVEMBER 2014 Table of Contents I. Executive Summary Objectives Description of Environmental Concerns Aircraft Washing Options

More information