Protection & Safety Equipments For Storage Tanks. Pressure / Vacuum Relief Valves, Flame Arresters, Free Vent, Gauge Hatch.

Size: px
Start display at page:

Download "Protection & Safety Equipments For Storage Tanks. Pressure / Vacuum Relief Valves, Flame Arresters, Free Vent, Gauge Hatch."

Transcription

1 Protection & Safety Equipments For Storage Tanks Pressure / Vacuum Relief Valves, Flame Arresters, Free Vent, Gauge Hatch ABS PV End. Valf San. ve Tic. A.S. Aydınlı Mah. Esenlik Sk. No : Tuzla / Istanbul Turkey Phone : Mail : abs@abspv.com

2

3 OUR COMPANY ABS PV Endustriyel Valf San. Tic. A.S., through its ABS PV Brand, has been designing and manufacturing Protection & Safety Equipments for Chemical Tankers such as High Velocity Pressure Vacuum Valves, Flame Arresters, Test Bench and Gas Free Cover since By 2016, our company has started to produce high quality pressure vacuum relief valves, flame arresters, free vent and gauge hatch for storage tanks. ABS PV is one of the world s well known company as a manufacturer of P/V Valves. Our Company presently on the certification process of ISO 9001:2008 Quality Management System. We offer high quality services and products with our professional team and customer focused strategies since years. ABS PV STORAGE TANK PROTECTION & SAFETY EQUIPMENTS ABS PV PRESSURE/VACUUM RELIEF VALVES provide tank protection by preventing the occurrence of excessive pressure & vacuum inside the tank. Also minimize the possible losses of product evaporation. The range includes pressure/vacuum relief valves, pressure only and vacuum only valves, all available with flanged pipeline or vented to atmosphere. All models of ABS PV Pressure Vacuum Relief Valves have weight loaded or spring loaded pallets which allow intake of air and outflow of vapours as the tank normally breathes in and out. Valves can be specially supplied with a flame arrester, inlet pipe or lining. ABS PV DEFLAGRATION FLAME ARRESTERS prevent passage of flame into the storage tanks. ABS PV End of Line Flame Arresters are designed to be installed at the end of a pipeline, In-Line Flame Arresters are designed to prevent propagation of flames in piping system. ABS PV FREE VENT prevents deformation that may occur during filling and discharging of the tanks. Free Vent is supplied as complete unit ready for direct installation. ABS PV GAUGE HATCH allows easy access to atmospheric liquid storage tanks for manual level measurement, temperature The production of our equipments consist of a series of quality check points, performed by the in-house quality assurance team. All components, at the end of each process are transferred to the next step via the control team, carrying out various test methods. As each process is subject to statistical quality control procedures, also traceability of each component in the design is assured. Therefore, the quality of each single product is guaranteed within the system. All models of ABS PV products are results of comprehensive design studies and shop tests. The design of ABS PV Products for Storage Tanks are in compliance with the regulations of Atex Directive 94/9 EC, Atex 2014/34/EU and ISO EN , ISO EN , ISO EN Standards and certificated by ATEX. 1

4 Pressure & Vacuum Relief Valve Model ABS PVV / O ABS PV PRESSURE/VACUUM RELIEF VALVE OPEN TO ATMOSPHERE Weight loaded Spring loaded ABS PV Pressure Vacuum Relief Valve Open to Atmosphere is intended for use where both pressure and vacuum relieves are required. The pallets in the vent housing allow intake of air and outflow of vapours as the tank normally breathes in and out. Pallets open and close to permit only that intake or outlet relief necessary to remain within permissible working pressures and avoid damage to the tank. Reduces losses due to evaporation of liquid inside the tank. Designed to protect against endurance burning by using flame screen. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC. Available in weight loaded and spring loaded types. C A B PRESSURE SETTING VACUUM SETTING MIN. MAX. MIN. MAX. UNITS mbar psi mbar psi mbar psi mbar psi ABS PVV/O-W 2,5 0, ,305-2,5-0, ,870 ABS PVV/O-S 75 1, , , ,305 (mm) (inch) A (mm) B (mm) C (mm) (mm) ,

5 Pressure & Vacuum Relief Valve ABS PV PRESSURE RELIEF TO CLOSED LINE VACUUM RELIEF TO ATMOSPHERE Model ABS PVV / PC ABS PV Pressure Relief to Closed Line Vacuum Relief to Atmosphere Valve is used for pressure relief where hazardous vapours must be piped away. Pressure vents to pipeline and vacuum vents from atmosphere. The pallets in the vent housing allow intake of air and outflow of vapours as the tank normally breathes in and out by using pipeline for pressure. Designed to protect against endurance burning by using flame screen. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC. Available in weight loaded and spring loaded types. D A PRESSURE SETTING VACUUM SETTING MIN. MAX. MIN. MAX. UNITS mbar psi mbar psi mbar psi mbar psi ABS PVV/PC-W 2,5 0, ,305-2,5-0, ,870 ABS PVV/PC-S 75 1, , , ,305 B C (mm) (inch) A (mm) B (mm) C (mm) D (mm) (mm) ,

6 Pressure & Vacuum Relief Valve Model ABS PVV / VC ABS PV PRESSURE RELIEF TO ATMOSPHERE VACUUM RELIEF TO CLOSED LINE ABS PV Pressure Relief to Atmosphere Vacuum Relief to Closed Line Valves are used for vacuum relief where hazardous vapours must be piped away. Vacuum vents to pipeline and pressure vents from atmosphere. The pallets in the vent housing allow intake of gas and outflow of vapours as the tank normally breathes in and out by using pipeline for vacuum. Designed to protect against endurance burning by using flame screen. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC. Available in weight loaded and spring loaded types. C A B PRESSURE SETTING VACUUM SETTING MIN. MAX. MIN. MAX. UNITS mbar psi mbar psi mbar psi mbar psi ABS PVV/VC-W 2,5 0, ,305-2,5-0, ,870 ABS PVV/VC-S 75 1, , , ,305 (mm) (inch) A (mm) B (mm) C (mm) (mm) ,

7 Pressure & Vacuum Relief Valve ABS PV PRESSURE/VACUUM RELIEF VALVE TO CLOSED LINE Model ABS PVV / C ABS PV Pressure Vacuum Relief Valve to Closed Line is designed to provide pressure and vacuum relief in applications that require hazardous vapours to be piped away, rather than released into the atmosphere. The pallets in the vent housing allow intake of gas and outflow of vapours as the tank normally breathes in and out by using pipeline. Pallets open and close to permit only that intake or outlet relief necessary to remain within permissible working pressures and avoid tank damage. Designed to protect against endurance burning by using flame screen. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC. Available in weight loaded and spring loaded types. D A PRESSURE SETTING VACUUM SETTING MIN. MAX. MIN. MAX. UNITS mbar psi mbar psi mbar psi mbar psi ABS PVV/C-W 2,5 0, ,305-2,5-0, ,870 ABS PVV/C-S 75 1, , , ,305 B C (mm) (inch) A (mm) B (mm) C (mm) D (mm) (mm) ,

8 Pressure Relief Valve Model ABS PV / O ABS PV PRESSURE RELIEF VALVE OPEN TO ATMOSPHERE ABS PV Pressure Relief Valve Open to Atmosphere is designed to meet the positive pressure change during filling and depending on the temperature variation during the day. The vapours relieved is vented to atmosphere. The valve offers reliable protection against excess pressure and prevents product losses almost up to the set pressure. Designed to protect against endurance burning by using flame screen. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC. Available in weight loaded and spring loaded types. A PRESSURE SETTING MIN. MAX. UNITS mbar psi mbar psi ABS PV/O-W 2,5 0, ,305 ABS PV/O-S 75 1, ,251 (mm) (inch) A (mm) (mm) ,

9 Pressure Relief Valve ABS PV PRESSURE RELIEF VALVE TO CLOSED LINE Model ABS PV / C ABS PV Pressure Relief Valve to Closed Line is intended for use where pressure relief is required and the relieved vapours must be piped away and not emitted into the atmosphere. A pallet in the vent housing opens and closes permitting relief necessary to avoid tank damage. Designed to protect against endurance burning by using flame screen. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC. Available in weight loaded and spring loaded types. A PRESSURE SETTING MIN. MAX. UNITS mbar psi mbar psi ABS PV/C-W 2,5 0, ,305 ABS PV/C-S 75 1, ,251 B (mm) (inch) A (mm) B (mm) (mm) ,

10 Vacuum Relief Valve Model ABS VV / O ABS PV VACUUM RELIEF VALVE OPEN TO ATMOSPHERE ABS PV Vacuum Relief Valve Open to Atmosphere is intended for use where only vacuum relief is required. A pallet in the vent housing retards air intake (from atmosphere) as the tank normally breathes in due to atmospheric temperature changes or emptying of the tank. The pallet opens and closes to permit only that intake relief necessary to avoid tank damage under normal operating conditions. Designed to protect against endurance burning by using flame screen. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC. Available in weight loaded and spring loaded types. C B VACUUM SETTING MIN. MAX. UNITS mbar psi mbar psi ABS VV/O-W -2,5-0, ,870 ABS VV/O-S -30-0, ,305 (mm) (inch) B (mm) C (mm) (mm) ,

11 Vacuum Relief Valve ABS PV VACUUM RELIEF VALVE TO CLOSED LINE Model ABS VV / C ABS PV Vacuum Relief Valve to Closed Line is used where vacuum relief must be piped away. The valve offers reliable protection against vacuum and prevents inbreathing of air almost up to the set vacuum, it also protects against atmospheric deflagration. Designed to protect against endurance burning by using flame screen. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC. Available in weight loaded and spring loaded types. C VACUUM SETTING MIN. MAX. UNITS mbar psi mbar psi ABS VV/C-W -2,5-0, ,870 ABS VV/C-S -30-0, ,305 B (mm) (inch) B (mm) C (mm) (mm) ,

12 Pressure & Vacuum Relief Valve Model ABS PVV-FA/2016I ABS PV PRESSURE VACUUM RELIEF VALVE WITH FLAME ARRESTER ABS PV Pressure Vacuum Relief Valve with Flame Arrester is a combination of ABS PV Pressure Vacuum Relief Valve Open to Atmosphere and ABS PV In-line Flame Arrester. Intended to protect your tank from damage created by overpressure or excessive vacuum, at the same time provides protection from externally caused sources of heat and ignition. Reduces emissions level and increases fire protection and safety. B Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 94/9/EC & ATEX 2014/34/EU Available in weight loaded and spring loaded types. Vent leakage is no more than 1 SCFH at 90% of the set pressure. A C (mm) (inch) A (mm) B (mm) C (mm) (mm) ,

13 Flame Arrester ABS PV IN-LINE FLAME ARRESTER Model ABS FA/2016I ABS PV s In-Line Deflagration Flame Arresters are designed to prevent propagation of flames in piping systems. By locating the arrester in close proximity to the potential source of ignition, any flame or explosion is confined to the immediate area. ABS PV arresters are supplied as complete units ready for direct installation. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 2014/34/EU Quick and easy installation Shall be installed vertically or horizontally. Vent leakage is no more than 1 SCFH at 90% of the set pressure. D A B (inch) (mm) A (mm) B (mm) C (mm) D (mm) , C 11

14 Flame Arrester Model ABS FA/2016E ABS PV END-OF-LINE FLAME ARRESTER ABS PV End of Line Deflagration Flame Arresters are designed to be installed at the end of a pipeline, where the ignition source is external, to provide protection against atmospheric deflagration. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to ATEX 2014/34/EU Quick and easy installation. Shall be installed vertically. Vent leakage is no more than 1 SCFH at 90% of the set pressure. C B A D (inch) (mm) A (mm) B (mm) C (mm) D (mm) ,

15 Free Vent ABS PV FREE VENT ABS FV ABS PV Free vents are designed for use on any atmospheric tank to prevent the build-up of internal pressure by allowing atmosphere and vapours to flow freely in tanks or vent riser pipes. It offers efficient flow capacity for protection of the tank. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to Ex Protection Type Quick and easy installation Shall be installed vertically. dxn K INCH K dxn x x x x x x x x

16 Gauge Hatch Model ABS GH ABS PV GAUGE HATCH ABS PV Gauge Hatch provides ready acces to storage tank s interior for inspection, gauging and sampling. Sizes available from 2 ( 50) to 12 ( 300). Designed and tested according to Ex Protection Type. Quick and easy installation. dxn K INCH K dxn x x x x x x x x

17 PRODUCTION CERTIFICATE This is to certify that the under noted product(s) has/have been tested with satisfactory results in accordance with the relevant requirements of the Regulations & Standards. This certificate is issued to : DATE : ORDER NUMBER : CLIENT / OWNER : DESCRIPTION : TYPE : QUANTITY : SERIAL NUMBERS : MATERIALS : Housing : ALUMINIUM, STAINLESS STEEL, CARBON STEEL Internals : AISI 316 SETTING VALUES : Pressure Side : Vacuum Side : SPECIFIED STANDARDS : EN ;2009, EN ;2011, EN 16852;2010 CERTIFICATE DIRECTIVES : 94/9/EC, 2014/34/EU CERTIFICATE NUMBERS : IEP 16 ATEX 0252, IEP 16 ATEX 0448 Warranty Close : This certificate also has been consist guarantee periods during 18 months. The failures which may cause from wrong use are out of warranty coverage. Operator must use the products as to instruction manual. Producer does not responsible in any failure and / or any defects which may result from wrong usage. MAKER ABS PV ENDÜSTRIYEL VALF SANAYI VE TICARET A.Ş. Aydınlı Mah. Esenlik Sok. No:6 Tuzla-ISTANBUL-TURKIYE Tel: (pbx) Faks: abs@abspv.com 15

18 EUROPEAN COMMUNITY DECLARATION OF CONFORMITY Issued in accordance with the ATEX 94/9/EC, ATEX 2014/34/EU Num:.. (order number) This is to certify that in compliance with the Council Directive 94/9/EC of 30 December 2006 and 2014/34/EU of 26 February Manufactured by Address : ABS PV Endüstriyel Valf Sanayi ve Tic. A.Ş. : Aydınlı Mah. Esenlik Sk. No: Tuzla İstanbul / Turkey declares that the product(s) detailed below conform(s) to type as required by the above Directives as evidenced by the Conformity Route below: EC Type Examination Certificate No. : IEP 16 ATEX 0252, IEP 16 ATEX 0448 EC Certificate of Conformity/Test : ATEX 94/9/EC, ATEX 2014/34/EU Item Designation : Provide tank protection by preventing the occurence of excessive pressure & vacuum inside the tank. Also minimize the possible losses of product evaporation. Prevent the passage of flame into the storage tanks. Manufacturer s Product Code No. or Type : ABS PVV/O, ABS PVV/PC, ABS PVV/VC, ABS PVV/C, ABS PV/O, ABS PV/C, ABS VV/O, ABS VV/C, ABS PVV-FA/2016I, ABS FA/2016I, ABS FA/2016E, ABS FV, ABS GH. Description : Standards Applicable EN ;2009 EN ;2011 EN 16852;2010 Product(s) Serial or Batch/Lot No(s) COMPANY NAME : Name : Title : Date:././20. Signature & Stamp Valves to be selected and installed in accordance with the manufacturer s instructions and recommendations, and subject to the user s obligations detailed in Standards Applicable on above. 16

19

20 ABS PV End. Valf San. ve Tic. A.S. Aydınlı Mah. Esenlik Sk. No : Tuzla Istanbul - Turkey Phone : Fax : Mail : abs@abspv.com

Flame arresters 4301A/4319A ATEX Approved

Flame arresters 4301A/4319A ATEX Approved Flame arresters 4301A/4319A ATEX Approved The Whessoe Vapour Control range of flame arresters are designed and certified for use in conjunction with Whessoe pressure and vacuum valves, as well as for use

More information

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 320. Product Description. (Vertical, in-line, detonation )

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 320. Product Description. (Vertical, in-line, detonation ) ATEX approved Flame Arrester (Vertical, in-line, detonation ) Model Number Product Description EGIL Storagetech Model In-line Detonation Flame Arrester is designed for installation in gas pipelines. Detonation

More information

Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases

Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases Typical KITO flame arrester elements, which prevent the propagation of flames and explosions (both

More information

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 300. Product Description. (Vertical, in-line, deflagration)

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 300. Product Description. (Vertical, in-line, deflagration) ATEX approved Flame Arrester (Vertical, in-line, deflagration) Model Number 300 Product Description EGIL Storagetech Model Number 300 Flame Arrester is a safety device that has a flame barrier with a large

More information

ANDERSON GREENWOOD TYPE 4410 SIDE ENTRY ATMOSPHERIC VACUUM RELIEF VALVES

ANDERSON GREENWOOD TYPE 4410 SIDE ENTRY ATMOSPHERIC VACUUM RELIEF VALVES Weight or spring loaded valves with a side inlet capable of high capacity vacuum relief. Designed to work closer to a tank's MAWV, increasing productivity, reducing emissions and product evaporation FEATURES

More information

KITO explosion and endurance burning flame arrester devices

KITO explosion and endurance burning flame arrester devices KITO flame arresters and fittings for the storage and transportation of inflammable liquids, vapours and gases. Designed to prevent fire penetration, explosions and detonations in tank installations of

More information

Operating Instruction Inline Detonation Flame Arrester

Operating Instruction Inline Detonation Flame Arrester Operating Instruction Inline Detonation Flame Arrester 1002-0008 IBExU 11 ATEX 2071 X 0102 G IIB3 Issue : 05.04.2012 Page 1 of 7 1. Preface These operating instructions apply to inline detonation flame

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) Model 6A00. Inline Deflagration Flame Arrestor SECTION I

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) Model 6A00. Inline Deflagration Flame Arrestor SECTION I INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) IOM-6A00 IIA1/IIA 03-16 ISO Registered Company Model 6A00 Inline Deflagration Flame Arrestor SECTION I I. DESCRIPTION AND APPLICATION As autonomous

More information

SERIES 670E End-of-Line Deflagration Flame Arrester

SERIES 670E End-of-Line Deflagration Flame Arrester SERIES 670E PROTECTOSEAL CAUTION: If any questions arise concerning the proper installation or maintenance of our products, please contact Protectoseal or one of our Authorized Representatives. When installing

More information

INSTALLATION AND MAINTENANCE

INSTALLATION AND MAINTENANCE System Series SDB A.GENERAL The Deflagration- and Endurance burning Flame Arresters, Series SDB, are intended for use in Piping Systems handling flammable Gases / Vapours of Gas Group Ex. IIA / I. B. GUIDANCE

More information

VAREC 5910B AND 5920B SERIES RELIEF VALVE WITH FLAME ARRESTER

VAREC 5910B AND 5920B SERIES RELIEF VALVE WITH FLAME ARRESTER These units combine the high flow capacity of a pressure and vacuum relief valve with an easy-to-maintain flame arrester for maximum protection and reliable operation FEATURES 5920B Oversized pressure

More information

MANAGEMENT SERVICE CRYOGENIC VALVES T E YKJ Phone: Fax:

MANAGEMENT SERVICE CRYOGENIC VALVES T E YKJ Phone: Fax: MANAGEMENT SERVICE 0036 W 0 / TRD 100 CRYOGENIC VALVES YKJ S T E 2016-11 Yakacık Cryogenic Valves Application Examples Yakacık Cryogenic Valves Technical Specifications Socket welded Operating Temperature

More information

DETONATION FLAME ARRESTER MODEL 7658A

DETONATION FLAME ARRESTER MODEL 7658A DETONATION FLAME ARRESTER MODEL 7658A Actual Video Frame USCG Approved Successfully Tested to Procedures Approved by USCG, IMO & CSA Multiple Flow Selections per Pipe Size In-line Maintenance Available

More information

VAREC 5810B AND 5820B SERIES RELIEF VALVE WITH FLAME ARRESTER

VAREC 5810B AND 5820B SERIES RELIEF VALVE WITH FLAME ARRESTER These units combine the high flow capacity of a pressure and vacuum relief valve with an extensible bank flame arrester to provide maximum protection and reliable operation FEATURES 5820B Oversized pressure

More information

Amal are not only known for the high quality of their products but also for the exemplary levels of commitment and dedication shown to their

Amal are not only known for the high quality of their products but also for the exemplary levels of commitment and dedication shown to their Amal are not only known for the high quality of their products but also for the exemplary levels of commitment and dedication shown to their customers.this commitment to complete customer satisfaction

More information

SOLENOID VALVE USER S MANUAL

SOLENOID VALVE USER S MANUAL SOLENOID VALVE USER S MANUAL PLEASE READ THE INSTRUCTIONS BEFORE USE Sept 2017 CONTENTS 1. PRODUCT OVERVIEW...3 a. Intended Use of the Product...3 b. Product Coding System...4 c. Lists of Exploded Pictures

More information

Biogas safety control equipment

Biogas safety control equipment Biogas safety control equipment As environmental concerns and energy efficiency are increasing, efficient economical and safe gas control systems become an increasingly important part of operating the

More information

Instructions for installation, service and maintenance 1. INTRODUCTION APPLICATION TECHNICAL DATA, IDENTIFICATION...

Instructions for installation, service and maintenance 1. INTRODUCTION APPLICATION TECHNICAL DATA, IDENTIFICATION... Flame arresters ADAST CONTENT 1. INTRODUCTION... 1 2. APPLICATION... 1 3. TECHNICAL DATA, IDENTIFICATION... 1 3.1 Technical description... 1 3.2 Identification... 2 3.3 Technical parameters... 2 Flame

More information

FRP VENTS. Fiberglass Reinforced Plastic Vents... No Exposed Metal Components. Distributed by Relevant Solutions relevantsolutions.

FRP VENTS. Fiberglass Reinforced Plastic Vents... No Exposed Metal Components. Distributed by Relevant Solutions relevantsolutions. FRP VENTS Fiberglass Reinforced Plastic Vents...... No Exposed Metal Components PROTECTOSEAL SERIES STYLE SIZES1 P8540 H End-of-Line Pressure / Vacuum 12" - 12" P18540 H Pipe-Away Pressure / Vacuum 12"

More information

Operating Instructions Inline Detonation Flame Arrester and

Operating Instructions Inline Detonation Flame Arrester and Operating Instructions Inline Detonation Flame Arrester 1002-0008 and 1002-0009 0102 PTB 04 ATEX 4003 X IIG IIB3 Issue : 27.11.2007 Page 1 of 7 1. Preface These operating instructions apply to inline detonation

More information

860 and 960 Series Spring-Loaded Pressure/ Vacuum Relief Valve (ATEX Approved)

860 and 960 Series Spring-Loaded Pressure/ Vacuum Relief Valve (ATEX Approved) Instruction Manual D103813X012 860 and 960 Series October 2017 860 and 960 Series Spring-Loaded Pressure/ Vacuum Relief Valve (ATEX Approved) Table of Contents Introduction...1 Specifications...2 Product

More information

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and Pressure Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models 532.52, 532.53 and 532.54 WIKA data sheet PV 25.02 for further approvals see page 4 Applications Control

More information

An Explosive Situation. Definitions

An Explosive Situation. Definitions An Explosive Situation Explosions due to flame arrester failures are destructive, expensive and potentially deadly. Prior to 1989, no arrester provided protection against all types of flame propagation.

More information

FULL LIFT TYPE VALVE AT 10% OVERPRESSURE

FULL LIFT TYPE VALVE AT 10% OVERPRESSURE FULL LIFT TYPE VALVE AT 10% OVERPRESSURE 1800A Series For applications requiring low emissions and operation near Maximum Allowable Working Pressure (MAWP) WHAT IS A FULL LIFT TYPE VALVE? A Full Lift Type

More information

Tank Fittings, Flame Arresters, Valves, Gauges, & Accessories

Tank Fittings, Flame Arresters, Valves, Gauges, & Accessories Tank Fittings, Flame Arresters, Valves, Gauges, & Accessories Tank Fittings & Flame Arresters by Shand & Jurs Today s growing markets call for keeping an increasingly larger supply of your products close

More information

BUS & TRUCK DRIVER SEATS

BUS & TRUCK DRIVER SEATS BUS & TRUCK DRIVER SEATS S e a t i n g S y s t e m s www.pilot.com.tr ABOUT US Pilot was established in 1963 doing body work for busses. First seat production started in 1967 with driver seats for Mercedes

More information

AEL.TF.16 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS

AEL.TF.16 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS AEL.TF.16 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS 0120 TS EN ISO 9001 CONTENTS Part Name Page No 0. Introduction 1 1. Introduction Technical Specifications of

More information

megaflo BSP Pressure Relief Vent

megaflo BSP Pressure Relief Vent Pressure RELIEF VENTS PRV s SECTION 2 When it comes to pressure/vacuum protection, Girard has been putting their name and reputation on the line every day for close to 60 years. We start with only the

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 16793 January 2016 ICS 23.060.40; 13.220.99 English Version Guide for the selection, application and use of flame arresters Guide pour la sélection,

More information

Pressure & Flame Protection

Pressure & Flame Protection Pressure & Flame Protection Tank Protection Valves Tank Protection Valves Marvac manufacture an extensive range of products to protect low pressure storage tanks and vessels.these products help to prevent

More information

94406 Vertical Inline Deflagration Flame Arrester. Features

94406 Vertical Inline Deflagration Flame Arrester. Features 94406 The Shand & Jurs 94406 Vertical Inline Deflagration Flame Arresters are designed to provide a positive flame stop on low pressure tanks or piping systems containing flammable liquids or solvents

More information

Laboratory Evaluation Report for: Laboratory Faucet Backflow Preventer

Laboratory Evaluation Report for: Laboratory Faucet Backflow Preventer American Society of Sanitary Engineering Seal (Certification) Program Laboratory Evaluation Report for: Laboratory Faucet Backflow Preventer Tested under ASSE Standard 1035 Revised: April, 2008 Laboratory

More information

COVER EQUIPMENT. VAREC BIOGAS 400W Series EMERGENCY RELIEF MANHOLE COVERS

COVER EQUIPMENT. VAREC BIOGAS 400W Series EMERGENCY RELIEF MANHOLE COVERS COVER EQUIPMENT VAREC BIOGAS 400W Series EMERGENCY RELIEF MANHOLE COVERS The 400W Series is designed to provide emergency pressure and/or vacuum relief in storage tanks and vessels. Introduction The Varec

More information

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment American Society of Sanitary Engineering Seal (Certification) Program Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment Tested under ASSE Standard 1022 ASSE: 2003 ANSI:

More information

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves CLASSIFICATION NOTES Type Testing Procedure for Crankcase Explosion Relief Valves Contents 1. Scope, Application 2. Recognized Standards 3. Purpose 4. Test Facilities 5. Explosion Test Process 6. Testing

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

SLK SERIES SAFETY VALVES

SLK SERIES SAFETY VALVES SLK SERIES SAFETY VALVES SLK SERIES TABLE OF CONTENTS Relief Valves SLK-Series are spring loaded pressure relieving devices, suitable for discharge of compressible fluids. SLK-series safety valves are

More information

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION II 2 G I M2 Ref. ID 2310, Rev. A Email: sales@cord-ex.com www.cordexinstruments.com CONTENTS 1. READ THIS FIRST 1. READ THIS FIRST 1 Liability 1 Trademark

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

SILOXA FAKA Gas Cleaning System

SILOXA FAKA Gas Cleaning System 1/8 Activated carbon adsorber for removing H 2 S from biogas SILOXA s FAKA gas cleaning systems are highly efficient systems that are available in different versions, with one or two chambers or as a TWIN

More information

Flame arresters/vents

Flame arresters/vents Flame arresters/vents Product information serving the gas industry worldwide Introduction RMG-GASELAN Regel- und Messtechnik GmbH is a company based in Germany. We produce devices and safety systems recommended

More information

Engineered Solutions For Your Tank Equipment Needs

Engineered Solutions For Your Tank Equipment Needs Engineered Solutions For Your Tank Equipment Needs Product Brochure World Leader in Tank Protection Flame & Deflagration Arresters Detonation Arresters Level Gauges Emissions Monitoring Conservation Vents

More information

VAREC 5810B/5820B Series. Relief Valve and Flame Arrester

VAREC 5810B/5820B Series. Relief Valve and Flame Arrester VAREC 0B/0B Series The 0B/0B Series is a combination of the 00B/00B Series and Relief Valve and the 000 Series Flame Arrester. INTRODUCTION The VAREC 0B/0B Series Relief Valve and Flame Arrester is a combination

More information

Instruction Manual. Ex-Time 40 / 50

Instruction Manual. Ex-Time 40 / 50 Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /

More information

EU Mutual Recognition Technical Requirements

EU Mutual Recognition Technical Requirements 1. PRODUCT DESCRIPTION... 1 1.a General description of the product... 1 1.b Application limitations... 1 1.c Intended use... 2 1.d System context... 2 2. DESIGN EVALUATION... 2 2.a Engineering evaluation

More information

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically

More information

Bulk Solids Feeding. Distributor for. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC

Bulk Solids Feeding. Distributor for. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC Bulk Solids Feeding Distributor for Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC High filling efficiency and precise metering

More information

FILTER, REGULATOR AND FILTER/REGULATOR stainless steel 316L compact 1/4, high flow 1/4-1/2

FILTER, REGULATOR AND FILTER/REGULATOR stainless steel 316L compact 1/4, high flow 1/4-1/2 FILTER, REGULATOR AND FILTER/REGULATOR stainless steel L compact /, high flow / - / Air Preparation Series FEATURES Stainless Steel, and intended for corrosive environment and suitable for use in potentially

More information

HYDRAULIC HOSES AND HOSE KITS

HYDRAULIC HOSES AND HOSE KITS HYDRAULIC HOSES AND HOSE KITS Liebherr Hydraulic Hoses and Hose Kits Liebherr-Australia Hose Production has been manufacturing high pressure hose assemblies in the Adelaide Head Office complex since 1999,

More information

Compact differential pressure switch Models DC, DCC

Compact differential pressure switch Models DC, DCC Mechatronic pressure measurement Compact differential pressure switch Models DC, DCC WIKA data sheet PV 35.40 Process Compact Series Applications Differential pressure monitoring and control of processes

More information

94407 Horizontal Inline Deflagration Flame Arrester

94407 Horizontal Inline Deflagration Flame Arrester 94407 The Shand & Jurs 94407 Horizontal Inline Deflagration Flame Arrester is designed to provide a positive flame stop in horizontal gas piping systems containing flammable vapors having a low flash point.

More information

W 0 / TRD 100 PISTON VALVES YVN - YVNB YVMN - YVSN T E Phone: Fax:

W 0 / TRD 100 PISTON VALVES YVN - YVNB YVMN - YVSN T E Phone: Fax: 00 W 0 / TRD 0 PISTON VALVES YVN - YVNB YVMN - YVSN S T E 01-0 Phone:+0 1 0 7 50 Fax: +0 1 77 01 YAKACIK Piston Valves YAKACIK VALF having long term experience on elastic sealing systems, designed piston

More information

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and Pressure Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models 990.22, 990.52 and 990.53 WIKA data sheet DS 99.41 for further approvals see page 7 Applications Sanitary applications

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

PROTEGO Detonation Flame Arresters. Volume 4. Volume 4. for safety and environment

PROTEGO Detonation Flame Arresters. Volume 4. Volume 4. for safety and environment PROTEGO Detonation Flame Arresters Volume 4 Volume 4 Detonation Flame Arrester Function and description The function of fl ame arresters in the various combustion processes and applications is discussed

More information

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Explosion proof electric motor For Fuel dispensing application. Main characteristic Ad-pe ed.2018/0 1 Explosion proof electric motor For Fuel dispensing application RAEL motori elettrici, since its inception in the late 60s, has assembled more than a million of explosion proof electric

More information

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves (Spring Loaded)

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves (Spring Loaded) Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves (Spring Loaded) Models L1201B, L1202B L1203A, L1221B, L1222B, L1223A, L1261A, L1301A, L1361A, L2301A 2010 Groth Corporation

More information

SPRING LOADED VENTS. Set Points of 3 PSIG and Above PROTECTOSEAL

SPRING LOADED VENTS. Set Points of 3 PSIG and Above PROTECTOSEAL SPRING LOADED VENTS Set Points of 3 PSIG and Above PROTECTOSEAL SERIES STYLE 9540 End-of-Line Pressure/Vacuum Breather Vent 19540 Pipe-Away Pressure/Vacuum Breather Vent 9240 End-of-Line Vacuum Relief

More information

Section 1-7. Nominal Flow 50 lpm 13 US gpm. Threads G3/8 (Standard) SAE8

Section 1-7. Nominal Flow 50 lpm 13 US gpm. Threads G3/8 (Standard) SAE8 Valve is equipped with an adjustable main relief valve, available in parallel circuit, wide range of spool options and positioners, interchangable spools Manual and remote cable Section 1 Weight 2,1 kg

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard. : BM 72 Hinged Window System. : Burak Aluminyum San ve Tic. A.Ş.

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard. : BM 72 Hinged Window System. : Burak Aluminyum San ve Tic. A.Ş. TEST REPORT Report Number : 020.413.1 / 2015 Report Date : 24 / 07 / 2015 Testing Reference Product Client : TS EN 14351-1 + A1 Windows and Doors - Product Standard : BM 72 Hinged Window System : Burak

More information

Armaturenwerk Hötensleben GmbH. Valve Technology. A member of NEUMO Ehrenberg Group. Edition 3.0

Armaturenwerk Hötensleben GmbH. Valve Technology. A member of NEUMO Ehrenberg Group. Edition 3.0 Armaturenwerk Hötensleben GmbH Valve Technology A member of NEUMO Ehrenberg Group Edition 3.0 Proven Valves for all Purpose ATEX Directive 2014/34/EU Armaturenwerk Hötensleben GmbH is using the revised

More information

TEST REPORT. Report Number : / Report Date : 12 / 03 / : TS EN A1 Windows and Doors - Product Standard

TEST REPORT. Report Number : / Report Date : 12 / 03 / : TS EN A1 Windows and Doors - Product Standard TEST REPORT Report Number : 020.530.1 / 2016 Report Date : 12 / 03 / 2016 Testing Reference : TS EN 14351-1 + A1 Windows and Doors - Product Standard Product : Asistal TH 78 Door and Window System ( Tilt

More information

Betriebsanleitung Operating Instructions. Oil Mist Filter

Betriebsanleitung Operating Instructions. Oil Mist Filter Betriebsanleitung Operating Instructions Oil Mist Filter ONF 4-20 idealvac.com (505)872-0037 idealvac.com PK 0169 BE/E (0906) Contents 1. Safety Instructions... 2 1.1. For Your Orientation... 2 2. Understanding

More information

TODO-GAS COUPLINGS TODO-GAS DRY-BREAK COUPLINGS

TODO-GAS COUPLINGS TODO-GAS DRY-BREAK COUPLINGS TODO-GAS COUPLINGS TODO-GAS couplings are specifically designed for the safe transfer of LPG (typically Propane / Butane) in both liquid and vapour phases. The materials of construction and component design

More information

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017 ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue 2017.1, Released December 13, 2017 Clark Cooper A Division of Magnatrol Valve Corp. 941 Hamilton avenue Roebling,

More information

IQL Helios Area-/Streetlight. User Manual

IQL Helios Area-/Streetlight. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...

More information

Mini temperature switch Stainless steel switch enclosure Model TXS

Mini temperature switch Stainless steel switch enclosure Model TXS Mechatronic temperature measurement Mini temperature switch Stainless steel switch enclosure Model TXS WIKA data sheet TV 31.70 Process Mini Series Applications Temperature monitoring and control of processes

More information

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech MAKING MODERN LIVING POSSIBLE Instruction ATEX instruction for APP 0.6-10.2 / PAH 2-100 PAHT G 2-90 / PAH 25-80 Tech danfoss.high-pressurepumps.com Table of Contents 1. Common demands for Category 2 and

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4 Data sheet Integrated emergency converter for fluorescent lamps zone 2 Ex 100,000 h suitable for zone 2 hazardous areas For mains and battery supply Integrated battery management inear V inear V Emergency

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1012 - REVISED: 2009 Backflow Preventers with an Intermediate Atmospheric Vent Separate, complete laboratory evaluation

More information

7. Evaporative Emission Control System

7. Evaporative Emission Control System W1860BE.book Page 10 Tuesday, January 28, 2003 11:01 PM 7. Evaporative Emission Control System A: GENERAL The evaporative emission control system prevents fuel vapors from escaping into atmosphere. This

More information

Compact pressure switch Model PCS

Compact pressure switch Model PCS Mechatronic pressure measurement Compact pressure switch Model PCS WIKA data sheet PV 33.30 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes

More information

Backflushing Filter AutoFilt RF3

Backflushing Filter AutoFilt RF3 Backflushing Filter AutoFilt C 2,5 4 6 8 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL The automatic back-flushing filter AutoFilt is a self-cleaning system for extracting particles from lowviscosity fluids.

More information

ATEX LABELLING FOR MOTORS AND GEAR UNITS

ATEX LABELLING FOR MOTORS AND GEAR UNITS ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and

More information

Peter Meyer Ball valves Cryogenic

Peter Meyer Ball valves Cryogenic Peter Meyer Ball valves Cryogenic Features Swiss manufacturer One-piece body design Laser welded, whitout body seal Chambered seats Cryogenic extension Cavity pressure relief system Replaceable packing

More information

Physical Technical Testing Institute Ostrava-Radvanice. Type Examination Certificate

Physical Technical Testing Institute Ostrava-Radvanice. Type Examination Certificate Physical Technical Testing Institute Ostrava-Radvanice Type Examination Certificate Equipment Intended for use in Potentially Explosive Atmospheres Directive 94/9/EC (3) Type Examination Certificate Number:,

More information

Drain ball valve BR 21a

Drain ball valve BR 21a PTFE - lined Drain ball valve BR 21a Application: Tight-closing PTFE-lined drain ball valve for corrosive media, especially for high process demand in chemical plants: Nominal sizes DN 50 to DN 150 Nominal

More information

BKV 4000 Bottom Blowdown Control Valve Installation and Operating Instructions

BKV 4000 Bottom Blowdown Control Valve Installation and Operating Instructions BKV 4000 Bottom Blowdown Control Valve Installation and Operating Instructions BKV 4000 MKK v10.01-en 1 CONTENTS 1. SAFETY INFORMATIONS... 3 2. DESCRIPTION... 3 3. TECHNICAL SPECIFICATIONS... 4 3.1. BKV

More information

SAFETY TRAINING LEAFLET 04 NITROUS OXIDE

SAFETY TRAINING LEAFLET 04 NITROUS OXIDE SAFETY TRAINING LEAFLET 04 NITROUS OXIDE Doc 23.04/18 EUROPEAN INDUSTRIAL GASES ASSOCIATION AISBL AVENUE DES ARTS 3-5 B 1210 BRUSSELS Tel: +32 2 217 70 98 Fax: +32 2 219 85 14 E-mail: info@eiga.eu Internet:

More information

SR100 Series Service Regulators. Technical Bulletin

SR100 Series Service Regulators. Technical Bulletin SR100 Series Service Regulators Technical Bulletin Model SR100 Series Regulator 02 Elster American Meter The compact, high capacity SR113 service regulator is designed for residential or light commercial/industrial

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 16852 Second edition 2016-10-15 Flame arresters Performance requirements, test methods and limits for use Arrête-flammes Exigences de performance, méthodes d essai et limites

More information

FILTER, REGULATOR AND FILTER REGULATOR stainless steel 316L compact 1/4, high flow 1/4, 1/2, 3/4 and 1

FILTER, REGULATOR AND FILTER REGULATOR stainless steel 316L compact 1/4, high flow 1/4, 1/2, 3/4 and 1 FILTER, REGULATOR AND FILTER REGULATOR stainless steel L compact /, high flow /, /, / and Air Preparation Series FEATURES Stainless Steel, Regulator and Regulator intended for corrosive environment and

More information

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar Pressure Differential pressure gauge For the process industry Models 732.14, 762.14, high overload safety up to 40, 100 or 400 bar WIKA data sheet PM 07.13 for further approvals see page 4 Applications

More information

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard : ASISTAL LS 60 SERIES HEBE-SCHIEBE SYSTEM

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard : ASISTAL LS 60 SERIES HEBE-SCHIEBE SYSTEM TEST REPORT Report Number : 020.557.1 / 2016 Report Date : 05 / 05 / 2016 Testing Reference Product : TS EN 14351-1 + A1 Windows and Doors - Product Standard : ASISTAL LS 60 SERIES HEBE-SCHIEBE SYSTEM

More information

Differential pressure switch Model DPS40

Differential pressure switch Model DPS40 Mechatronic pressure measurement Differential pressure switch Model DPS40 WIKA data sheet PV 27.21 DELTA-switch Applications Monitoring and control of filters, compressors and pumps in: Marine boilers,

More information

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications Bulletin 71.1 D103087X012 Type HSR December 2017 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications High Capacity Compact Design P1524_1 High Capacity Internal

More information

Garlock Butterfly Valves Technical Catalog Trusted throughout the chemical, petrochemical & many other industries

Garlock Butterfly Valves Technical Catalog Trusted throughout the chemical, petrochemical & many other industries Technical Catalog Trusted throughout the chemical, petrochemical & many other industries Garlock Butterfly Valves Trusted throughout chemical, petrochemical and many other industries FOR CORROSIVE AND

More information

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing Mechatronic pressure measurement Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing WIKA data sheet PV 27.22

More information

valve & automation PNEUMATIC ACTUATORS USER MANUAL PLEASE READ THE INSTRUCTIONS BEFORE USE JUNE

valve & automation PNEUMATIC ACTUATORS USER MANUAL PLEASE READ THE INSTRUCTIONS BEFORE USE JUNE PNEUMATIC ACTUATORS USER MANUAL PLEASE READ THE INSTRUCTIONS BEFORE USE JUNE 201 CONTENTS 1. GENERAL DESCRIPTION OF THE EQUIPMENT...3 a. Intended Use Of The Equipment...3 b. Product Coding System...4 c.

More information

Si Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Si Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions Safety valves for pressure relief in accordance to PED, DIN/EN and ASME Engineering GREAT Solutions Features Typical regular safety valve for many applications The modern pressure safety valve for regular

More information

Flameproof Enclosures

Flameproof Enclosures Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical

More information

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Model TB TECHNICAL BULLETIN. Pressure / Vacuum Vent with Pipe-Away

Model TB TECHNICAL BULLETIN. Pressure / Vacuum Vent with Pipe-Away TECHNICAL BULLETIN 3200 - TB 04-16 Pallet Diaphragm Material: FEP TFE - Standard. Also available in FKM, EPDM and Buna-N. ISO Registered Company Model 3200 Pressure / Vacuum Vent with Pipe-Away OBJECTIVE

More information

Model ES-660-HF High Flow Spring-Loaded Hatch

Model ES-660-HF High Flow Spring-Loaded Hatch Instruction Manual Model ES-660-HF February 2015 Model ES-660-HF High Flow Spring-Loaded Hatch Table of Contents Introduction...1 Specifications...2 Principle of Operation...2 Tagging Information...2 Installation

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information