MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER
|
|
- Claud Holt
- 5 years ago
- Views:
Transcription
1 MODL TX either ducted or nonducted applications. Its roof or sidewall mounting options permit location near the area to be and buildings. Typical applications include restaurant hoods and similar your application.
2 MODL TX cooling. Standard with single speed dripproof and totally enclosed motors. Air handling type ball bearings with cast iron housing and construction standard. 1 year warranty. proper belt tension. Spun Shroud performance sound. irdscreen Assures dependable operation. Stainless Steel xterior Fasteners Standard. For optimum air and sound performance. For electrical reliability. Assures rating of Sound and Air performance. 9
3 MODL TX STANDARD CONSTRUCTION FATURS AND OPTIONS Model TXRHUL UL762 Restaurant xhaust Spun Top asily removable for servicing. Drives Sized for 150% of drive HP, adjustable pitch sheaves. Motor Open dripproof construction standard. 1 year warranty. nclosed Motor Compartment Isolates motor and drives from exhaust air. Oversized Vent Tube For maximum motor cooling. Motor ase Motor is adjustable for proper belt tension. earings Air handling type ball bearings with cast iron housing and Spun Shroud Provides maximum air performance. xternal WaterTight Disconnect Switch Standard with single speed dripproof and totally enclosed motors. Hinged Curb Cap (Optional) For easy access to ductwork. Deep Spun One Piece Inlet For optimum air and sound performance. All Aluminum Centrifugal Wheel Nonoverloading, backward inclined and minimum sound. Grease Drain Fitting For connection of Grease Trough or Grease Grabber. Aluminum Grease Trough (Optional) Grease containment system. Prefabricated Roof Curb (Optional) 18" minimum required for restaurant applications. Factory Run & Tested Assures dependable operation. AMCA Seal Assures rating of Sound and Air performance. Stainless Steel xterior Fasteners Standard. Neoprene Isolators Reduce vibration and sound. UL Label For electrical reliability. 10
4 MODL TX required accessories. 11
5 MODL TX Option. which call for products with enhanced safety and structural resistance. The where the air is discharged directly up and away from the roof surface. designed,, tested and manufactured standards TAS 20194, and , Impact Test Procedures. HWL, include the following features 12
6 MODL TX Automatic elt Tensioners eliminate the need for regular Motor Pulley elt Tensioner Pulley elt Tensioner Arm Fan Pulley elt Tensioner reduction in startup and maintenance costs, increased belt do not snag obstructions. for easy duct access. current submittal for details. 13
7 MODL TX TX shown herein are licensed to bear based on test and procedures performed 14
8 MODL TX TX TX1002 TX TX TX TX TX TX TX TX TX1014 TX TX TX1020 TX1021 TX1022 shown herein are licensed to bear the on test and procedures performed in ac 15
9 MODL TX Ship TX TX TX TX TX TX TX TX TX12334 TX12501 TX12502 TX TX Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the
10 MODL TX Ship TX TX TX TX TX TX TX TX TX TX15502 TX TX TX TX TX TX TX TX15152 shown herein are licensed to bear the on test and procedures performed in ac
11 MODL TX TX shown herein are licensed to bear based on test and procedures performed
12 MODL TX Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the 19
13 S MODL TX TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the 20
14 S MODL TX TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the 21
15 S MODL TX 32 Ship TX TX20252 TX TX20332 TX TX TX TX TX TX TX TX TX20153 TX TX TX TX TX TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the 22
16 S MODL TX 32 Ship TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the 23
17 S MODL TX 42 Ship TX TX TX TX TX TX TX TX TX TX TX TX TX24151 TX TX TX TX TX TX TX TX TX TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the 24
18 S MODL TX TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the 25
19 S MODL TX Ship TX30331 TX TX TX TX30502 TX TX TX TX TX TX TX30153 TX TX TX TX TX TX TX TX TX TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ shown herein are licensed to bear the on test and procedures performed in ac
20 S MODL TX TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the
21 S MODL TX 44 Ship TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ shown herein are licensed to bear the based on test and procedures performed
22 S MODL TX 44 Ship TPVO boe QFSGPSNODF NPWFNFOU O!DPOUSPM TTPDJUJPO JOUFSOUJPOM!JOD/ Ventilation Group, certifies that the Models TX shown herein are ratings shown are based on test and procedures performed in accordance Publication 311 and comply with the 29
MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER
Model Features Exhaust air up to 6,817 CFM in high static pressure applications up to 3 Belt drives permit easy performance adjustments when needed Nonoverloading backward inclined wheel for efficiency
More informationIndustry best 5 year fan housing warranty, 1 year motor warranty
MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading
More informationMODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER
MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationMODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER
MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationMODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS
MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company
More informationCentrifugal Spun Aluminum Products
Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview
More informationEcoWatt Products. Advancing Ventilation
EcoWatt Products Advancing Ventilation EcoWatt-0817 August 2017 What is EcoWatt At S&P we strive to engineer and manufacture the most efficient products in the market. In order to categorize our most energy
More informationRoof Upblast and Sidewall Exhaust
XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,
More informationRoof Upblast and Sidewall Exhaust
XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and
More informationIndustry best 5 year fan housing warranty, 1 year motor warranty
MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationMODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN
MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company
More informationCENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK
CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall
More informationEXHAUST FANS CUD & CUB UPBLAST FANS
EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment
More informationCentrifugal Spun Aluminum Products
Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview
More informationIndustry best 5 year fan housing warranty, 1 year motor warranty
MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2
More informationCentrifugal Spun Aluminum Products
Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview
More informationDownblast Centrifugal Fans with ECM
Downblast Centrifugal Fans with ECM Model ered Featuring Electronically Commutated Motors GC_eRED_0512 May 2012 1 Motor Up to 90% efficient, electronically commutated motor (ECM) DOWNBLAST CENTRIFUGAL
More informationCentrifugal Upblast Power Roof Ventilators
INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM
More informationAdvancing Ventilation
Centrifugal oof Sidewall LPD CWD STXD STXDe SDBD SDBDe SDB STXB Direct Drive Belt Drive Centrifugal oof Sidewall Fans Advancing Ventilation centrifugal-roof--sidewall-0219 February 2019 MODEL LPD LOW POFILE
More informationCentrifugal Exhaust Fans Series C. Roof Upblast and Sidewall
Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with
More informationUtility Sets Standard Design Features Standard design features common to all Class I and Class II fans
Standard Design Features Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Shaft AISI 1045, turned ground and polished for accuracy. Designed to provide
More informationBelt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2.
BDU Belt Drive - Centrifugal Up-Blast Fans W HT F Grease Drain B R RO Features & Benefits Complete range of motors available to meet specific application needs Heavy duty construction, durable and weather
More informationDESIGN GUIDELINES FANS PAGE 1 of 7
DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the
More informationCentrifugal Filtered Supply Fans
Centrifugal Filtered Supply Fans Model KSF Application/Construction Options/Accessories Construction Features Performance/Dimensions NFPA96 Installation/Common TXB Series Restaurant Exhauster Additional
More informationSPUN ALUMINUM POWER ROOF AND WALL VENTILATORS
BULLETIN 0 January 007 SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS TYPE ACX / ACXD TYPE ATD / ATDR / ATDW / ATDWR TYPE ATB / ATBR / AWX / AWXR Model ACX Model ATB Model ACXD Model ATDR Model AWX Centrifugal
More informationSECTION HVAC POWER VENTILATORS
SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationTubular Centrifugal Fans
Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,
More informationRoof & Sidewall Mounted
G, G Roof & Sidewall Mounted 4 E40001 - G and G UL/cUL Power Ventilators for Smoke ontrol Systems MH11711 - G UL/cUL Listed 705 is standard on In Stock models G and G are M Licensed for Sound and ir Performance
More informationSECTION AXIAL HVAC FANS
SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationAMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty
MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading
More informationMODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER
MODEL CWD MODEL FEATURES Exhaust air up to 3,360 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationforward curved inline duct blowers
Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationFKUB Belt Drive - Centrifugal Up-Blast Fans
FKUB Belt rive - Centrifugal Up-Blast Fans W HT F Grease rain B R RO C Features & Benefits Complete range of motors available to meet specific application needs Heavy duty construction, durable and weather
More informationSECTION CENTRIFUGAL HVAC FANS
SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationAir Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV
Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one
More informationMODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS
MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades
More informationWholesale Ventilation Products
Wholesale Ventilation Products... better AIRFLOW by ESIGN! RM IRECT RIVE AXIAL EXHAUST FANS RM Axial Exhaust Fans are suitable for roof or wall mounting in commercial ventilation applications. They are
More informationUTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.
UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most
More informationTwin City Fan & Blower
BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE
More informationBELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the
More informationBelt Drive Centrifugal Roof Exhauster Model PV
Belt Drive Centrifugal Roof Exhauster Model PV Model PV belt drive fans are centrifugal power roof ventilators designed for exhausting clean air. Capacities up to 40,608 CFM and up to 2 inch static pressure.
More informationCONSTRUCTION FEATURES AND OPTIONS
MODEL SQD & esqd MODEL FEATURES Exhaust air up to 2,8 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space
More informationThe Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD
The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information
More informationMODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS
S CSF & LSF Model CSF Hooded Design FEATURES Supply air to over 13,000 CFM in static pressure capabilities to 2 w.g. Heavy-galvanized construction Belt drives permit easy performance adjustments when needed
More informationDirect Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast
Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall Roof Downblast Models LPD & RED LPD Applications/Construction LPD Performance/Dimensions RED Applications/Construction RED Performance/Dimensions
More informationbelt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07
belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 model vp - belt drive utility set Application VENT-PAK fan wheels are the versatile, quiet, energy efficiency backward inclined
More informationSafety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements.
CWBA Sizes 12 to 20 711 to 5709 CFM Static Pressure to 2 AMCA Licensed Ratings for Sound and Air CWDA Sizes 06 to 20 133 to 4942 CFM Static Pressure to 1 AMCA Licensed Ratings for Sound and Air Safety
More informationQuickship Program. Quick Delivery Wide Product Selection Competitive Price
Quickship Program Centrifugal Roof & Wall Exhausters Centrifugal Filtered Supply Propeller Roof Ventilators Propeller Wall Fans Recovery Ventilators Utility Sets Ceiling/Cabinet Fans Gravity Ventilators
More informationSQUARE INLINE CENTRIFUGAL FANS
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower
More informationTURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV
TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the
More informationMODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS
MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available
More informationTamper Proof Downblast Centrifugal Exhaust Ventilators Page
SRSH Tamper Proof Downblast Centrifugal Exhaust Ventilators Page Introduction....................................... 2 SRSH-D Specifications and Dimension Data............. 3 SRSH-B Specifications and
More informationMIN/MAX PERFORMANCE IN INCHES WG
Fans Roof Exhaust Direct Drive - G Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels
More informationCommercial Fans & Dampers
Commercial Fans & Dampers CUD DIRECT DRIVE UPBLAST FANS FEATURES & BENEFITS Suitable for roof or wall mount Backward inclined, non-overloading wheels Spun aluminum housing for weather-resistant durability
More informationCentrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive
Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation
More informationTwin City Fan & Blower
Twin City Fan & Blower BULLETIN 405 April 2009 UPBLAST ROOF, WALL, & KITCHEN EXHAUSTERS TYPE DCRU / DCRUR / DCRW / DCRWR TYPE BCRU / BCRUR / BCRW / BCRWR TYPE BCRUSH (Smoke & Heat) Upblast Roof, Wall,
More informationCentrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...
More informationMODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE
BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit
More informationINDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS
INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with
More informationQuickship Program Quick Delivery Wide Product Selection Competitive Price
Quickship Program Quick Delivery Wide Product Selection Competitive Price Centrifugal Roof & Wall Exhausters Centrifugal Filtered Supply Propeller Roof Ventilators Propeller Wall Fans Recovery Ventilators
More informationMODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS
UPBLAST PROPELLER FANS Model LUBK SECTION 16 MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS Application Model LUBK is a high capacity roof mounted exhauster rated from 3,560 to 42,000 CFM. It
More informationINLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK
INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the
More informationPropeller Hooded Roof Fans
Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive
More informationMODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN
R BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and
More informationCommercial & Industrial Ventilation Complete Line of Sustainable Products
ommercia l Kitchen Ventilation ommercial & Industrial Ventilation omplete Line of Sustainable Products 919.88.4 800.334.956 919.88.504 (fax) www.captiveaire.com ontents entrifugal Upblast xhaust Fans N-F
More informationMODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS
Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except
More informationCentrifugal Inline Fans
Centrifugal Inline Fans Models SQ-M and SQ-M Direct and elt Drive UILDING VLUE IN IR. February January 2018 2017 Models SQ-M & SQ-M Centrifugal Square Inline Duct Fans Designed for indoor and outdoor clean
More informationSquare Inline Fans with Multi-Directional Discharge
SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension
More informationMODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN
R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial
More informationMODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN
TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside
More informationTwin City Fan & Blower
Twin City Fan & Blower BULLETIN 4050 November 2009 DOWNBLAST ROOF EXHAUSTERS TYPE DCRD / BCRD (Spun Aluminum Housing) TYPE BCRD-E (Endurex Polymeric Housing) Downblast Roof Exhausters Twin City Fan & Blower
More informationCentrifugal Filtered Supply Roof Blowers
CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................
More informationMODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER
MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside
More informationTube Axial Inline Fans
Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the
More informationTwin City Fan & Blower
Twin City Fan & Blower VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE FCV (Forward Curved) Ventilating
More informationMODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS
Model FF Model FFC MODEL FF FEATURES Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation Speed
More informationTube Axial Fan Page Specifications & Dimension Data Performance Data
Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications
More informationInline and Roof Mounted Fans
CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive
More information.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.
Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072
More informationUPBLAST ROOF, WALL & KITCHEN EXHAUSTERS
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH CATALOG 405 APRIL 08 ROOF & WALL EXHAUSTERS
More informationTubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct
Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-
More informationTURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH
TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH CATALOG 405 February 207 ROOF & WALL EXHAUSTERS Overview Roof & Wall Exhausters Twin
More information200, 9200 & 9200-VIB SERIES
DUCT VENTILATION 200 SERIES Indoor Applications, Insulated or Non-Insulated 9200 SERIES Heavy duty, Insulated Indoor or Outdoor Applications SUBJECT TO CHANGE WITHOUT NOTICE - 04/7 Optional motor, drive
More informationFixed Pitch Vane Axial Fan
Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3
More informationYour Clean Air Source!
Direct Drive Your Clean Air Source! HIGH QUALITY... HIGH FFICINCY... VRSATILITY stablished in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial
More informationMODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER
MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside
More informationCentrifugal Ventilators Direct-Drive Upblast Centrifugal Roof & Wall Ventilators
Direct-Drive Upblast Centrifugal Roof & Wall Ventilators Direct-drive upblast ventilators are designed for continuous operation to exhaust foul air, smoke, fumes, odors and grease-laden vapors from range
More informationPropeller Upblast Roof Fans
Propeller Upblast Roof Fans Models RBU, RBUMO, RDU and RGU Direct Drive, Belt Drive and Gravity April 2010 Propeller Upblast Roof Fans Greenheck upblast propeller fans are designed to discharge contaminants
More informationMixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data
Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8
More informationK SERIES SIDEWALL PROPELLER FANS
K SERIES S Models LWBK/LMBK and LRBK/LNBK K SERIES S The Carnes Sidewall Propeller Fan series Models LW/LM and LR/LN have been designed for quiet and efficient air flow performance with the lowest possible
More informationInline Fans [ 14 ] * UL is optional and must be specified.
XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC
More informationCentrifugal Cabinet Fans Model BCF Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or
More informationYour Clean Air Source!
Direct Drive Your Clean Air Source! HIGH QUALITY... HIGH FFICINCY... VRSATILITY stablished in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial
More informationFILTERED SUPPLY CENTRIFUGAL Belt Drive
FILTERED SUPPLY CENTRIFUGAL Belt Drive FILTERED SUPPLY CENTRIFUGAL - BELT DRIVE SECTION 9 Carnes Models VSBB and VHBB centrifugal filtered roof supply fans are available in six sizes - 8 through 20 with
More information