Quickship Program Quick Delivery Wide Product Selection Competitive Price

Size: px
Start display at page:

Download "Quickship Program Quick Delivery Wide Product Selection Competitive Price"

Transcription

1 Quickship Program Quick Delivery Wide Product Selection Competitive Price Centrifugal Roof & Wall Exhausters Centrifugal Filtered Supply Propeller Roof Ventilators Propeller Wall Fans Recovery Ventilators Utility Sets Ceiling/Cabinet Fans Gravity Ventilators Inline Duct Fans Upblast Restaurant Exhausters QS0411 April

2 Table of Contents Ship Programs / Warranty... 3 Centrifugal Roof & Wall Exhausters Model LPD Low Profile Direct Drive Roof/Sidewall Exhauster... 4 Model DB Downblast Belt Drive Roof Exhauster... 5 Model RED Downblast Direct Drive Roof Exhauster... 7 Model TXD Upblast Direct Drive Roof Exhauster... 9 Model TXB-UL762 Upblast Belt Drive (Restaurant Roof Exhauster) Model CWD Direct Drive Sidewall Exhauster Centrifugal Filtered Supply Model KSF Belt Drive Filtered Roof Supply Fan Mixed Flow/Centrifugal Inline Fans Model TD Inline Mixed Flow Duct Fan Model TD Bathroom Exhaust Kits Model PV Centrifugal Inline Duct Fan Model PV Bathroom Exhaust Kits Model SWF Centrifugal Sidewall Duct Fan Clothes Dryer Boosing Kits Model SQB Square Inline Belt Drive Duct Fan Model SQD Square Inline Direct Drive Duct Fan Recovery Ventilators Model TR Total Recovery for All Climates - The Ultimate ERV Propeller Roof Ventilators Model UBS Upblast Belt Drive Roof Exhauster Model ARE/ARS Dome Direct Drive Exhaust/Intake Roof Ventilator Propeller Wall/Duct Fans Model WA & DA Compact Wall & Duct Axial Fan Model CSTR Shutter Fans Model GED Sidewall Direct Drive Propeller Fan Model LC Sidewall Belt Drive Propeller Fan Model L2 Heavy Duty Sidewall Belt Drive Propeller Fan Utility Vent Sets Model CM Gravity Ventilators Model RCXII Gravity Relief/Intake Ventilator Ceiling/Cabinet Fans Model V Ceiling Mounted Bath Fan Model FF/FFC Ceiling & Inline/Cabinet Fans Models IF and HP Industrial Ceiling Fans Accessories Roof Curbs Dampers For Roof Ventilators Wall Shutters Wall Housing Assembly Models Cross Reference

3 Quickship Program Shipping Schedules for each catalog item are shown with one of the following symbols. Please refer to your price list or contact your sales representative for specific product availability. Quantities per order are limited to stock on hand. = Next Day Shipment from Stock = 10 Day Build-to-Order Program = 3 Day Shipment from Stock Freight Policy Please refer to your price list for Freight Policy or contact your sales representative. Shipping points may vary on occasion, but typically all products ship from Jacksonville, FL USA Please check with your sales representative or our customer service team regarding shipment schedules & stock product availability, larger orders, additional accessories, special construction, technical support, application assistance, replacement parts, or any other service we can provide for you. Limited Warranty Soler & Palau (Manufacturer) 6393 Powers Avenue, Jacksonville, Florida 32217, warrants equipment of its manufacture to be free from defects in design, materials and workmanship (exclusive of abrasion, corrosion or erosion) for five (5) years (unless otherwise noted) from the date of shipment to the original purchaser or the date of notification of readiness to ship. Motor warranty is one (1) year (unless otherwise noted). In order to claim the benefit of this warranty, buyer must notify manufacturer in writing of the claimed defect within ten (10) days after discovering it and return this equipment or parts to the manufacturer with transportation prepaid. In the event of on-site repair, no service technician will be dispatched until manufacturer receives your written purchase order. If any of the following conditions exist, the warranty will be null and void: (1) Buyer has permitted other persons not approved or authorized by manufacturer to alter, adjust, replace or repair the equipment or any part thereof. (2) Buyer has not followed instructions or other directions given in the contract documents or our maintenance manual. (3) When breakage or other loss or damage is the result of any negligence, misuse or fault on the part of any operator or other person not under our supervision or control. (4) The defect is the result of designs or drawings made, furnished or specified by others. (5) In the case of goods not manufactured but supplied by the manufacturer as part of a contract, manufacturer shall only be liable to the same extent that our supplier is to manufacturer, not to exceed any liability manufacturer would have for warranty on our own equipment. (6) Buyer has not paid in full invoices submitted to the buyer which are due for payment. (7) Unusual wear and tear of the equipment. Statements relating to the product, its use or installation made prior to the execution of the agreement, are not warranties except to the extent that the contrary is expressly set forth herein. It is understood that such statements were not intended to, and did not, form a part of the agreement; they were merely made in the course of negotiations of the parties. THIS WARRANTY IS IN LIEU OF ANY OTHER EXPRESSED OF IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MER- CHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. OUR SOLE AND EXCLUSIVE OBLIGATION UNDER THIS WARRANTY IS TO REP OR REPLACE DEFECTIVE EQUIPMENT OR PARTS OR, AT OUR OPTION, TO PAY THE REASONABLE COST OF REP OR REPLACEMENT. BUYER AGREES THAT NO OTHER REMEDY (INCLUDING, BUT NOT LIMITED TO, INCIDENTAL OR CONSEQUENTIAL DAMAGES, DAMAGE FOR LOST PROFITS OR SALES, OR DAMAGES FOR INJURIES TO PERSON OR PROPERTY) SHALL BE AVAILABLE. NOTWITHSTANDING THE ABOVE, THE TOTAL AMOUNT THAT MAY IN ANY EVENT BE PAYABLE IN SETTLEMENT OR LIABILITY, HOWEVER INCURRED, SHALL NOT EXCEED THE CONTRACT PRICE. 3

4 R CENTRIFUGAL ROOF & WALL EXHAUSTERS LPD LOW PROFILE DIRECT DRIVE CENTRIFUGAL ROOF/SIDEWALL EXHAUSTER FEATURES Ultra low profile AMCA Air & Sound Licensed UL 705 listed UPS shipping carton 5 year housing warranty Up to 140 F airstream temperature Roof or sidewall mount CONSTRUCTION Aluminum construction Stainless steel exterior fasteners Backward curved centrifugal wheel Aluminum birdscreen Conduit wiring chase Service disconnect switch Precision balanced to ISO Standard 1940 MOTOR Unique external rotor design Permanently lubricated bearings 3 year motor warranty Internal thermal protection 100% speed controllable Totally enclosed and continuous duty AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models LPD shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. LISTED POWER ROOF VENTILATOR UL STANDARD 705 DIMENSIONAL DATA LPD LPD STATIC PRESSURE 0 1/8 1/4 3/8 1/2 5/8 3/ /4 1 1/2 1 3/4 RPM (NOM.) LPD O.D. DAMPER 12 HIGH ROOF CURB ROOF OPENING GRAVITY DAMPER CURB O.D. A B C DAMPER MOTOR (LOOSE) 115 VOLT SPEED CONTROL STOCK NO. STOCK NO. STOCK NO. STOCK NO AVERAGE SHIP WT. LBS /4 14-3/4 16-1/ / /4 14-3/4 16-1/ /2 15 PERFORMANCE DATA Performance certified is for installation type A-free inlet, free outlet. Performance ratings include the effects of birdscreen in the airstream. The sound ratings shown are loudness values in fan 5 (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. ACCESSORIES MAX MOTOR WATTS & AMPS 1/2 VENTILATOR WITH TE MOTOR 115/1/60 STOCK NO. 90 WATTS 7.2 LPD061AS 0.8 AMPS 115 WATTS 11.9 LPD081AS 1.0 AMPS *Base unit=amca Seal for Sound Rating does not apply to units with speed control + RPM range capable with solid state speed control. Speed (RPM) shown is normal. Performance is based on actual speed of test. Ship Schedules: Next Day Shipment From Stock 4 ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.

5 R DB DOWNBLAST BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER APPLICATION Model DB belt drive units are used for the exhaust of relatively clean air from a wide range of commercial, industrial and institutional environments such as manufacturing and assembly plants, office buildings, schools, hospitals, restaurants, athletic facilities and many others. The nonoverloading wheel with its higher static pressure capabilities makes this unit suitable for either ducted or nonducted applications. It s roof mounting permits location near the area to be ventilated, allowing short duct runs and more efficient operation. The aluminum exterior provides an attractive appearance. Belt drive results in lower operating RPM and sound levels, making the Model DB well suited to applications where quiet operation is important. Belt drive also permits easy performance adjustments when needed to balance the total ventilation system. CONSTRUCTION Housing Heavy-gauge aluminum for extra strength with prepunched mounting hole. Neoprene isolators for reduction of vibration and sound. Cover easily removed for quick access to motor compartment. Water tight conduit tube for easy electrical connection from below roof. Aluminum birdscreen and disconnect are included on standard models. Stainless steel exterior fasteners. Centrifugal Wheel All aluminum backward inclined wheel. Nonoverloading for safe operation in ducted systems. Statically and dynamically balanced for smooth operation. Motors Single speed open drip-proof are standard. All motors are rated for continuous duty. 182T and larger motors shipped unmounted for field installation. Disconnect switch standard with single speed drip-proof motors. Bearings Heavy-duty ball bearing type. Prelubricated and permanently sealed. AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models DB shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. CENTRIFUGAL ROOF & WALL EXHAUSTERS Drives Sized for minimum 150% of drive horsepower. Machined cast iron adjustable motor pulleys. Adjustable base for belt tensioning. Nonstatic oil resistant v-belts. LISTED POWER ROOF VENTILATOR UL STANDARD 705 DIMENSIONAL DATA DB A B C D E F ROOF OPENING Average Ship Wt. Lbs /2 17 1/2 16 1/2 3 1/2 16 1/8 1 3/4 11 1/ / /2 22 1/ / / /4 2 1/2 19 1/ / /2 4 1/2 26 1/4 2 1/2 24 3/ / /2 4 1/2 26 1/4 2 1/2 24 3/ /4 26 1/2 35 3/4 8 1/ /2 30 3/ / /2 5 1/ /2 37 3/ / / /2 37 3/4 475 ACCESSORIES DB RECOMMENDED 12 HIGH MOUNTING CURB RECOMMENDED GRAVITY DAMPER DAMPER MOTOR (LOOSE) FAN LESS MOTOR & DRIVE OD STOCK NO. OD STOCK NO. STOCK NO. STOCK NO / DB06LMDS-DB08LMDS-DB09LMDS / DB11LMDS-DB12LMDS-DB14LMDS / DB16LMDS / DB18LMDS / DB20LMDS / DB24LMDS / DB30LMDS / DB36LMDS Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 5

6 CENTRIFUGAL ROOF & WALL EXHAUSTERS DB Model DB Motor Hp Max. BHp RPM 1/4 SP Downblast Belt Drive Centrifugal Roof Exhauster CFM at Static Pressure 115/1/60* Ventilator with Open Drip-proof Motor and Drive Assembly /3/60 0 1/8 1/4 3/8 1/2 5/8 3/ /4 Stock No. Stock No. 1/ DB06ML1S N/A 1/ DB06MH1S N/A 1/ DB08ML1S N/A 1/ DB08MM1S N/A 1/ DB08MH1S N/A 1/ DB09MH1S N/A 1/ DB09PH1S N/A 1/ DB11MH1S DB11MH3S 1/ DB11PH1S DB11PH3S 1/ DB12MH1S DB12MH3S 1/ DB12PH1S DB12PH3S 1/ DB12QH1S DB12QH3S 1/ DB14MH1S DB14MH3S 1/ DB14PH1S DB14PH3S 1/ DB14QH1S DB14QH3S 3/ DB14RH1S DB14RH3S 1/ DB16MH1S DB16MH3S 1/ DB16PH1S DB16PH3S 1/ DB16QH1S DB16QH3S 3/ DB16RH1S DB16RH3S 1/ DB18PH1S DB18PH3S 1/ DB18QH1S DB18QH3S 3/ DB18RH1S DB18RH3S DB18SH1S DB18SH3S 1 1/ DB18TH1S DB18TH3S DB18VH1S DB18VH3S 1/ DB20PH1S DB20PH3S 1/ DB20QH1S DB20QH3S 20 3/ DB20RH1S DB20RH3S DB20SH1S DB20SH3S 1 1/ DB20TH1S DB20TH3S DB20VH1S DB20VH3S 1/ DB24PH1S DB24PH3S 1/ DB24QH1S DB24QH3S 24 3/ DB24RH1S DB24RH3S DB24SH1S DB24SH3S 1 1/ DB24TH1S DB24TH3S DB24VH1S DB24VH3S 1/ DB30QH1S DB30QH3S 3/ DB30RH1S DB30RH3S DB30SH1S DB30SH3S 1 1/ DB30TH1S DB30TH3S DB30VH1S DB30VH3S N/A DB30WH3S 3/ DB36RH1S DB36RH3S DB36SH1S DB36SH3S / DB36TH1S DB36TH3S DB36VH1S DB36VH3S N/A DB36WH3S N/A DB36XH3S Power ratings (BHP) do not include transmission losses. Performance certified is for installation type A-free inlet, free outlet. Performance ratings include the effects of birdscreen in the airstream. The sound ratings shown are loudness values in fan 5 (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. *Tri-voltage ( ) is standard on 3/4 through 1 1/2 Hp Single phase motors. Tri-voltage is available for the 1/2 Hp motors. Inquire for price and delivery. 6

7 R RED DOWNBLAST DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER APPLICATION Model RED direct drive units are used to exhaust air from all types of commercial and institutional buildings such as hospitals and health care facilities, schools, recreational buildings, machinery and equipment rooms, offices, retail stores and similar applications. The nonoverloading wheel with its higher static pressure capability makes this unit suitable for either ducted or nonducted applications. It s roof mounting permits location near the area to be ventilated, allowing short duct runs and more efficient operation. The spun aluminum exterior provides an attractive appearance and is compatible with belt driven Model DB and companion gravity units to make up a complete ventilation system. Direct drive units use smaller diameter wheels, resulting in low sound levels and quiet operation. They have no belts or fan bearings to maintain or adjust and consequently require very little maintenance. CONSTRUCTION Housing Curb cap has prepunched mounting holes for ease of installation. Fan plate isolates motor compartment from contaminated exhaust air. Spun aluminum hood and skirt for weather protection and attractive appearance. Heavy-gauge motor support for rigidity and strength Neoprene isolators for reduction of vibration and sound. Quick access to motor compartment for ease of maintenance. Conduit passage for easy electrical connection from below roof. Aluminum birdscreen and disconnect are included on standard models. Centrifugal Wheel Non overloading for safe operation in ducted systems. Backward inclined wheels constructed of noncorrosive aluminum. Statically and dynamically balanced for smooth operation. ACCESSORIES Solid State Speed Control: Control is matched to the motor and blower wheel to allow continuous reduction in performance allowing adjustments of airflow for system balancing. CFM is reduced in direct proportion to motor speed reduction. Speed control is only available for single phase. Exhauster performance can be controlled from the ventilated area. AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau, USA, certifies that the Models RED shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. LISTED POWER ROOF VENTILATOR UL STANDARD 705 CENTRIFUGAL ROOF & WALL EXHAUSTERS Speed Controllable Motors Standard motors are single speed, speed controllable and drip-proof. All motors are rated for continuous duty. Disconnect is standard with single speed drip-proof motors. Motors ship mounted as standard. DIMENSIONAL DATA RED A B C D ROOF OPENING Average Ship Wt. Lbs / /2 1 3/4 11 3/ /4 15 3/4 16 1/2 1 3/4 11 3/ /4 17 1/4 16 1/2 1 3/4 11 3/ /8 23 1/ / /8 23 1/ /4 124 ACCESSORIES RED RECOMMENDED 12 HIGH MOUNTING CURB RECOMMENDED GRAVITY DAMPER DAMPER MOTOR (LOOSE) 115 VOLT SPEED CONTROL 230 VOLT SPEED CONTROL OD STOCK NO. OD STOCK NO. STOCK NO. STOCK NO. STOCK NO. STOCK NO / N/A / N/A / N/A / / N/A SPEED CONTROL MAX 1/3 HP-5 AMP 120V MAX 1/2 HP-10 AMP 120V Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 7

8 CENTRIFUGAL ROOF & WALL EXHAUSTERS RED Model RED Motor Hp Max. BHp RPM 1/8 SP Downblast Direct Drive Centrifugal Roof Exhauster Ventilator with Open Drip-proof Motor CFM at Static Pressure 115/1/ /1/60 0 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1 Stock No. Stock No. 6 1/ RED06JH1AS RED06JH1CS 1/ RED08HM1AS N/A 8 1/ RED08JH1AS RED08JH1CS 10 1/ RED10MH1AS RED10MH1CS 1/ RED12MM1AS RED12MM1CS 12 1/ RED12QH1AS RED12QH1CS 15 1/ RED15QM1AS RED15QM1CS Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance certified is for installation type A-free inlet, free outlet. Performance ratings include the effects of birdscreeen in the airstream. The sound ratings shown are the loudness values in the fan 5 (1.5m) in an hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. Performance Data at Reduced Speed Sones CFM at Static Pressure Model Motor Max. RED HP BHP 1/8 SP 0 1/8 1/4 3/8 1/2 5/8 3/4 7/ / / / / / / / Model in reduced speed table indicates size and motor RPM of base unit. Performance is for that base unit operated at a reduced speed using the solid state speed control accessory. AMCA Seal for sound rating does not apply to units with speed control. Use 5 AMP Speed Control for motors 1/3 HP and smaller. Use 10 AMP Speed Control for motors 1/2. 8

9 R TXD-UL762 (UL762 for sizes only) UPBLAST DIRECT DRIVE CENTRIFUGAL ROOF/SIDEWALL EXHAUSTER FOR RESTAURANT AND GENERAL APPLICATIONS APPLICATION Isolation of the motor from the air stream and the high velocity vertical (roof) or horizontal (wall) air discharge make the Model TXD ideally suited for the removal of dirty, contaminated and/or high temperature air from processes and buildings. Typical applications include restaurant hoods and similar kitchen exhaust ventilation, fume and smoke removal, laboratory fume hood exhaust and chemical process exhaust. The nonoverloading wheel with its higher static pressure capability makes this unit suitable for either ducted or nonducted applications. Its roof or wall mounting permits location near the area to be ventilated, allowing short duct runs and more efficient operation. Direct drive units use smaller diameter wheels, resulting in low sound levels and quiet operation. They have no belts or fan bearings to maintain or adjust and consequently require very little maintenance. CONSTRUCTION Housing Heavy-gauge aluminum housing and curb cap for strength and rigidity. Stainless steel exterior fasteners. Enclosed, ventilated motor compartment isolates motor from exhaust air. Neoprene isolators for reduction of vibration and sound. The motor compartment housing easily removes for complete maintenance access. Water-tight conduit tube for easy electrical connection without having to wire through the breather tube. Mounted disconnect is included on standard models. Centrifugal Wheel Nonoverloading backward inclined for safe operation in ducted systems. Wheels constructed of noncorrosive aluminum. Statically and dynamically balanced for smooth operation. DIMENSIONAL DATA TXD A B C D ROOF OPENING Average Ship Wt. Lbs / / / / / / / / / /4 120 ACCESSORIES TXD RECOMMENDED 12 HIGH MOUNTING CURB RECOMMENDED GRAVITY DAMPER DAMPER MOTOR (LOOSE) 115 VOLT SPEED CONTROL Speed Controllable Motors Standard motors are single speed, speed controllable and drip-proof. All motors are rated for continuous duty. Disconnect is standard with single speed drip-proof motors. Motors ship mounted as standard. ACCESSORIES Solid State Speed Control: Control is matched to the motor and blower wheel to allow continuous reduction in performance allowing adjustments of airflow for system balancing. CFM is reduced in direct proportion to motor speed reduction. Speed control is only available for single phase. Exhauster performance can be controlled from the ventilated area. AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. 230 VOLT SPEED CONTROL OD STOCK NO. OD STOCK NO. STOCK NO. STOCK NO. STOCK NO TXD RECOMMENDED 12 HIGH MOUNTING CURB 18 HIGH MOUNTING CURB RECOMMENDED GRAVITY DAMPER DAMPER MOTOR (LOOSE) Soler & Palau USA, certifies that the Models TXD shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. LISTED POWER ROOF VENTILATOR UL STANDARD 705 sizes 6-8 UL STANDARD 762 sizes ONLY 115 VOLT SPEED CONTROL Sizes 6-8 are not suitable for Restaurant applications 230 VOLT SPEED CONTROL OD STOCK NO. STOCK NO. OD STOCK NO. STOCK NO. STOCK NO. STOCK NO. STOCK NO V N/A / V / V N/A / V N/A TXD HINGED BASE KIT METAL GREASE BOX GREASE GRABBER *You can not use a damper in a grease application SPEED CONTROL MAX 1/3 HP-5 AMP 120V STOCK NO. STOCK NO. STOCK NO MAX 1/2 HP-10 AMP 120V A ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE HD Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment CENTRIFUGAL ROOF & WALL EXHAUSTERS 9

10 CENTRIFUGAL ROOF & WALL EXHAUSTERS TXD Model TXD Motor Hp Max. BHp RPM 1/8 SP Upblast Direct Drive Centrifugal Roof/Sidewall Exhauster Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance certified is for installation type A-free inlet, free outlet. Performance ratings include the effects of birdscreeen in the airstream. The sound ratings shown are the loudness values in the fan 5 (1.5m) in an hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. Performance Data at Reduced Speed Model Motor Max. CFM at Static Pressure RPM TXD Hp BHp 0 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1 1/8 SP / / / / / / / / Model in reduced speed table indicates size and motor RPM of base unit. Performance is for that base unit operated at a reduced speed using the solid state speed control accessory. Ventilator with Open Drip-proof Motor CFM at Static Pressure 115/1/ /1/60 0 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1 Stock No. Stock No. 6 1/ TXD06JH1AS TXD06JH1CS 1/ TXD08MM1AS TXD08MM1CS 8 1/ TXD08MH1AS TXD08MH1CS 10 1/ TXD10RHULMH1AS TXD10RHULMH1CS 1/ TXD12RHULMM1AS TXD12RHULMM1CS 12 1/ TXD12RHULQH1AS TXD12RHULQH1CS 14 1/ TXD14RHULMM1AS TXD14RHULMM1CS 15 1/ TXD15RHULQM1AS TXD15RHULQM1CS 3/ TXD15RHULRH1AS - AMCA Seal for sound rating does not apply to units with speed control. Use 5 AMP Speed Control for motors 1/3 HP and smaller. Use 10 AMP Speed Control for motors 1/2. 10

11 R TXB-UL762 UPBLAST BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER FOR RESTAURANT AND GENERAL EXHAUST APPLICATION Isolation of motor and drive components from the air stream and the high velocity vertical air discharge make the model TXB-UL762 ideally suited for the removal of dirty, contaminated and/or high temperature air from processes and buildings. Typical applications include restaurant hoods and similar kitchen exhaust ventilation, fume and smoke removal, laboratory fume hood exhaust and chemical process exhaust. For grease removal applications the fan must be installed per NFPA 96 and with a 40 discharge height and hinged access base. CONSTRUCTION Housing Heavy-gauge aluminum housing and prepunched galvanized steel curb cap. Enclosed, ventilated motor/drive compartment isolates motor and drives from exhaust air. The motor compartment housing easily removes for complete maintenance access. Water-tight conduit tube for easy electrical connection without having to wire through the breather tube. External weather proof disconnect is included on standard models. Centrifugal Wheel Nonoverloading backward inclined for safe operation in ducted systems. Heavy aluminum hub for extra strength. Statically and dynamically balanced for smooth, quiet operation. DIMENSIONAL DATA TXB A B C D E ROOF OPENING Average Ship Wt. Lbs / /4 11 3/ / /4 11 3/ / / /4 2 1/2 19 1/ / /4 2 1/2 19 1/ / /2 37 3/4 28 1/2 31 3/4 2 1/2 24 3/ /2 47 1/4 31 1/ /2 30 3/4 245 Motors Single speed drip-proof motors are provided on standard models. All motors are rated for continuous duty. Disconnect switch is standard with single speed drip-proof motor. Drives Sized for minimum 150% of drive horse power. Machined cast iron adjustable motor pulleys. Adjustable base for belt tensioning. Static resistant v-belt. Bearings Heavy-duty cast pillow block ball bearing type. Prelubricated with zerk fitting. Designed for 200,000 hour average life. AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models TXB shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. LISTED POWER ROOF VENTILATOR UL STANDARD 705 UL STANDARD 762 Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment CENTRIFUGAL ROOF & WALL EXHAUSTERS ACCESSORIES TXB RECOMMENDED 12 HIGH MOUNTING CURB (1) 18 HIGH MOUNTING CURB RECOMMENDED DAMPER DAMPER MOTOR (LOOSE) 1 - RESTAURANT CURBS MUST BE 18 HIGH MINIMUM PER NFPA DO NOT USE DAMPER FOR FANS IN GREASE REMOVAL APPLICATIONS PER NFPA MAXIMUM 3 HP MOTOR - CONTACT FACTORY FOR 5 HP CONSTRUCTION. 4 - DO NOT USE FOR UL762 APPLICATIONS FAN LESS MOTOR & DRIVE HINGED BASE KIT HD (TXB8-18) (TXB20-24) METAL GREASE BOX GREASE GRABBER (TXB8-18) (TXB20-24) BIRDSCREEN (4) OD STOCK NO. STOCK NO. OD STOCK NO. STOCK NO. STOCK NO. STOCK NO. STOCK NO. STOCK NO. STOCK NO V TXB08RHULLMDS A KIT V TXB10RHULLMDS A KIT / V TXB12RHULLMDS A KIT / V TXB15RHULLMDS A KIT / V TXB16RHULLMDS A KIT / V TXB18RHULLMDS B KIT / V TXB20RHULLMDS B KIT / V TXB24RHULLMDS B KIT ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 11

12 CENTRIFUGAL ROOF & WALL EXHAUSTERS TXB-UL762 Model TXB Motor Hp Max. BHp RPM 1/4 SP Upblast Belt Drive Centrifugal Restaurant Roof Exhauster Ventilator with Open Drip-proof Motor and Drive Assembly CFM at Static Pressure 115/1/60* /460/3/60 0 1/4 3/8 1/2 5/8 3/ /4 Stock No. Stock No. 1/ TXB08RHULML1S N/A 1/ TXB08RHULMH1S N/A 1/ TXB08RHULPH1S N/A 1/ TXB10RHULMH1S TXB10RHULMH3S 1/ TXB10RHULPH1S TXB10RHULPH3S 1/ TXB10RHULQH1S TXB10RHULQH3S 1/ TXB12RHULMH1S TXB12RHULMH3S 1/ TXB12RHULPH1S TXB12RHULPH3S 1/ TXB12RHULQH1S TXB12RHULQH3S 1/ TXB15RHULMH1S TXB15RHULMH3S 1/ TXB15RHULPH1S TXB15RHULPH3S 1/ TXB15RHULQH1S TXB15RHULQH3S 3/ TXB15RHULRH1S TXB15RHULRH3S TXB15RHULSH1S TXB15RHULSH3S 1/ TXB16RHULQH1S TXB16RHULQH3S 3/ TXB16RHULRH1S TXB16RHULRH3S TXB16RHULSH1S TXB16RHULSH3S 1/ TXB18RHULQH1S TXB18RHULQH3S 3/ TXB18RHULRH1S TXB18RHULRH3S TXB18RHULSH1S TXB18RHULSH3S 1 1/ TXB18RHULTH1S TXB18RHULTH3S 1/ TXB20RHULQH1S TXB20RHULQH3S 20 3/ TXB20RHULRH1S TXB20RHULRH3S TXB20RHULSH1S TXB20RHULSH3S 1 1/ TXB20RHULTH1S TXB20RHULTH3S 1/ TXB24RHULPH1S TXB24RHULPH3S 1/ TXB24RHULQH1S TXB24RHULQH3S 24 3/ TXB24RHULRH1S TXB24RHULRH3S TXB24RHULSH1S TXB24RHULSH3S 1 1/ TXB24RHULTH1S TXB24RHULTH3S TXB24RHULVH1S TXB24RHULVH3S Power ratings (BHP) do not include transmission losses. Performance certified is for installation type A-free inlet, free outlet. Performance ratings include the effects of birdscreen in the airstream. The sound ratings shown are loudness values in fan 5 (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. *Tri-voltage ( ) is standard on 3/4 through 1 1/2 Hp Single phase motors. Tri-voltage is available for the 1/2 Hp motors. Inquire for price and delivery. 12

13 R CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER APPLICATION Models CWD are used to exhaust relatively clean air from a variety of industrial, commercial and institutional buildings such as machinery and equipment rooms, storage areas, office buildings, restaurants, retail stores, schools and similar buildings. The nonoverloading centrifugal wheel with its high static pressure capability, makes it suitable for either ducted or nonducted applications. The spun aluminum exterior provides a pleasing appearance, weather proof construction and resistance to corrosion. The low silhouette design is less noticeable on the building exterior and the removable dome provides easy access to the fan interior for service and cleaning. Direct drive units use smaller diameter wheels, resulting in low sound levels and quiet operation. They have no belts or fan bearings to maintain or adjust and consequently require very little maintenance. CONSTRUCTION Housing Spun aluminum dome for weather protection and attractive appearance. Ventilated motor compartment with motor out of air stream for long troublefree service. Dome easily removes for access to motor compartment. Weather-tight construction with aluminum birdscreen. Round duct connection provided at wheel inlet. Centrifugal Wheel Nonoverloading backward inclined for safe operation in ducted systems. Statically and dynamically balanced for smooth, quiet operation. Motors Speed controllable motors available on most models. Single speed open drip-proof are standard. Plug disconnect switch standard with single speed drip-proof motors. ACCESSORIES Solid State Speed Control: Control is matched to the motor and blower wheel to allow continuous reduction in performance allowing adjustments of airflow for system balancing. CFM is reduced in direct proportion to motor speed reduction. Speed control is only available for single phase. Exhauster performance can be controlled from the ventilated area. AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CWD shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. LISTED POWER ROOF VENTILATOR UL STANDARD 705 CENTRIFUGAL ROOF & WALL EXHAUSTERS DIMENSIONAL DATA CWD A B C D E G Average Ship Wt. Lbs /16 1 1/ / / / / / / / / / / ACCESSORIES CWD RECOMMENDED GRAVITY DAMPER DAMPER MOTOR (LOOSE) 115 VOLT SPEED CONTROL 230 VOLT SPEED CONTROL OD STOCK NO. STOCK NO. STOCK NO. STOCK NO. 7 8 x N/A 8 11 x N/A 9 14 x x x x Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment SPEED CONTROL MAX 1/3 HP-5 AMP 120V MAX 1/2 HP-10 AMP 120V ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 13

14 CENTRIFUGAL ROOF & WALL EXHAUSTERS CWD Model CWD Motor Hp Max. BHp RPM 1/8 SP Direct Drive Centrifugal Sidewall Exhauster Ventilator with Open Drip-proof Motor CFM at Static Pressure 115/1/ /1/60 0 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1 Stock No. Stock No. 7 1/ CWD07HH1AS N/A 8 1/ CWD08IH1AS N/A 9 1/ CWD09MM1AS CWD09MM1CS 1/ CWD09MH1AS CWD09MH1CS 10 1/ CWD10PH1AS CWD10PH1CS 12 1/ CWD12MM1AS CWD12MM1CS 14 1/ CWD14QM1AS CWD14QM1CS Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance certified is for installation type A-free inlet, free outlet. Performance ratings include the effects of birdscreeen in the airstream. The sound ratings shown are the loudness values in the fan 5 (1.5m) in an hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. Performance Data at Reduced Speed Sones Model Motor Max. CFM at Static Pressure CWD Hp BHp 1/8 SP 0 1/8 1/4 3/8 1/2 5/8 3/4 7/ / / / / / / / Model in reduced speed table indicates size and motor RPM of base unit. Performance is for that base unit operated at a reduced speed using the solid state speed control accessory. AMCA Seal for sound rating does not apply to units with speed control. Use 5 AMP Speed Control for motors 1/3 HP and smaller. Use 10 AMP Speed Control for motors 1/2. 14

15 R KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION Models KSF fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and industrial applications such as manufacturing and assembly areas. Model KSF s rugged design with heavy-gauge galvanized construction provides maximum weather protection, long life and the utmost in performance efficiency. The forward curved centrifugal blower provides efficient air flow at low sound levels. Filters are washable and are reusable to reduce maintenance costs. Quick release hood latches make routine cleaning and maintenance fast and easy. CONSTRUCTION Blower Statically and dynamically balanced forward curved wheel. Prepunched mounting holes. Conduit opening for wiring from below unit. Disconnect switch is standard equipment. Hood Heavy-gauge galvanized steel. Quick-release latches for removal from housing. Insulated for sound absorption and moisture barrier. 1 inch washable aluminum mesh filters. Drives Machined cast iron adjustable motor pulleys standard through 3 HP. Pivoting motor plate for belt tensioning. Static resistant v-belts. Bearings Heavy-duty ball bearing type. Prelubricated and permanently sealed. Motors Open drip-proof construction is standard. Optional motor enclosures and types can be specified. AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models KSF shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. LISTED POWER ROOF VENTILATOR UL STANDARD 705 CENTRIFUGAL FILTERED SUPPLY DIMENSIONAL DATA KSF A B C D ROOF OPENING Average Ship Wt. Lbs /4 24 1/2 17 1/ / /4 28 1/ / /2 32 1/2 26 3/8 26 3/ /4 32 1/2 31 1/2 31 1/ /4 36 1/2 35 1/2 35 1/ ACCESSORIES KSF RECOMMENDED 12 HIGH MOUNTING CURB RECOMMENDED GRAVITY DAMPER DAMPER MOTOR (LOOSE) FAN LESS MOTOR & DRIVE OD STOCK NO. OD STOCK NO. STOCK NO. STOCK NO / S3GA16CB MP2781 KSF0910LMDS / S3GA20CB MP2781 KSF1010LMDS CSF 24 S3GA24CB MP2781 KSF1210LMDS CSF 24 S3GA24CB MP2781 KSF1510LMDS CSF 27 S3GA27CB MP2781 KSF1810LMDS Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 15

16 CENTRIFUGAL FILTERED SUPPLY KSF Model KSF 9 10 Motor Hp Max. BHp 1/ Belt-Drive Centrifugal Filtered Roof Supply Fan Single Phase Three Phase Outlet 115/208/ /230/460 RPM at Static Pressure CFM Velocity STOCK NO. STOCK NO. FPM 1/8 1/4 3/8 1/2 5/8 3/ /4 1 1/ KSF09ML1S ( RPM) KSF09MH1S ( RPM) KSF09ML3S ( RPM) KSF09MH3S ( RPM) / KSF09PH1S KSF09PH3S / KSF09QH1S KSF09QH3S 3/ KSF09RH1S KSF09RH3S KSF09SH1S KSF09SH3S 1/ KSF10MH1S KSF10MH3S 1/ KSF10PH1S KSF10PH3S 1/ KSF10QH1S KSF10QH3S 3/ KSF10RH1S KSF10RH3S KSF10SH1S KSF10SH3S 1 1/ KSF10TH1S KSF10TH3S 1/ KSF12MH1S KSF12MH3S / KSF12PH1S KSF12PH3S / KSF12QH1S KSF12QH3S 3/ KSF12RH1S KSF12RH3S KSF12SH1S KSF12SH3S 1 1/ KSF12TH1S KSF12TH3S N/A KSF12VH3S Power ratings (BHP) do not include transmission losses. Performance certified is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). 575/3/60 ODP Motors are available for most motor HP s - Refer to Price List. Table shows fan RPM needed for required CFM and SP. Shaded/Non-shaded area shows motor HP and stock number to order. 16

17 KSF Model KSF Motor Hp Max. BHp Belt-Drive Centrifugal Filtered Roof Supply Fan Single Phase Three Phase Outlet 115/208/ /230/460 RPM at Static Pressure CFM Velocity STOCK NO. STOCK NO. FPM 1/8 1/4 3/8 1/2 5/8 3/ /4 1 1/2 1/ KSF15MH1S KSF15MH3S Power ratings (BHP) do not include transmission losses. Performance certified is for installation type B-free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). 575/3/60 ODP Motors are available for most motor HP s - Refer to Price List / KSF15PH1S KSF15PH3S / KSF15QH1S KSF15QH3S / KSF15RH1S KSF15RH3S KSF15SH1S KSF15SH3S 1 1/ KSF15TL1S ( RPM) KSF15TH1S ( RPM) KSF15TL3S ( RPM) KSF15TH3S ( RPM) N/A KSF15VH3S N/A KSF15WH3S 1/ KSF18MH1S KSF18MH3S / KSF18PH1S KSF18PH3S / KSF18QH1S KSF18QH3S / KSF18RH1S KSF18RH3S KSF18SH1S KSF18SH3S 1 1/ KSF18TH1S KSF18TH3S N/A KSF18VH3S N/A KSF18WH3S Table shows fan RPM needed for required CFM and SP. Shaded/Non-shaded area shows motor HP and stock number to order. CENTRIFUGAL FILTERED SUPPLY 17

18 18 CENTRIFUGAL FILTERED SUPPLY KSF Sound Power Data Model KSF RPM SP Sound Power RE Watts Octive Bands, Hz The sound power level ratings shown are in decibels referred to watts calculated per AMCA Standard 301. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for outlet Lwo sound power levels for: Installation Type-B: free inlet, ducted outlet. Ratings include the effects of duct end connection. dba levels are not licensed by AMCA International. L WD db(a)

19 KSF Sound Power Data Model KSF RPM SP Sound Power RE Watts Octive Bands, Hz The sound power level ratings shown are in decibels referred to watts calculated per AMCA Standard 301. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for outlet Lwo sound power levels for: Installation Type-B: free inlet, ducted outlet. Ratings include the effects of duct end connection. dba levels are not licensed by AMCA International. L wo db(a) CENTRIFUGAL FILTERED SUPPLY 19

20 MIXED FLOW/CENTRIFUGAL INLINE FANS TD INLINE MIXED FLOW DUCT FAN APPLICATION The S&P TD-MIXVENT series of in-line duct fans have been specially designed to maximize the airflow performance with minimal noise levels within the smallest and most compact of casing sizes. This makes the TD-MIXVENT series the ultimate solution for small to medium sized ventilation installations which require a high airflow to pressure ratio and occupy only the minimum space possible. Example: false ceiling voids, cupboards and many other limited space environments. The TD-MIXVENT consists of seven (7) nominal sized in-line fans. All models are specifically designed for direct connection in-line with industry standard diameter round ducting. CONSTRUCTION The TD-MIXVENT models 100, 100x, 125,150, and 200 are manufactured in tough reinforced plastic, models 250 and 315 have a metal casing and are finished in a tough epoxy-polyester paint coating. The TD fan duct connection flanges are manufactured from reinforced plastic, except for models 200, 250 and 315 which are constructed from epoxy-polyester coated metal. TD 250 and 315 are UL listed for outdoor use. Impellers The impeller blades for models 100, 100x, 125 and 150 are molded in tough ABS plastic. Models 200, 250 and 315 are metal. DIMENSIONAL DATA Model X A B C D E F G H TD /16 9 1/8 5 7/16 3 3/4 3 7/8 3 1/4 3 3/4 1 7/8 2 1/16 Motors Models 100, 100x and 125: Single-phase, 120V 60Hz, shaded pole induction asynchronous motor in die cast aluminum. All motors include direct two speed connection and are also suitable for voltage speed control. Class ll electrical insulation (model 100) & Class l (models 100x and 125) IP 44 Protection Class B Motor Insulation Safety auto reset Thermal Overload Protection (fuse type) Self-lubricating sleeve bearings. Suitable for working airstreams up to 104 F (40 C). Models 150, 200, 250 and 315: Single-phase induction asynchronous motor, with permanent capacitor and external rotor in die cast aluminum. All models include direct two speed connection and are also suitable for voltage speed control. Suitable for working airstreams up to 140 F (60 C). Class I electrical insulation IP 44 Protection Thermal Overload Protection Class B Motor Insulation Sealed For Life, ball bearings Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other random factors. It is generally accepted that remote mounted venting is usually quieter than standard (in room) venting. TD-100x 7 3/ / /16 4 1/2 3 13/ /16 3 9/16 3 1/8 2 3/8 TD /8 10 3/ /16 4 1/2 4 13/ /16 3 9/16 3 1/8 2 3/8 TD /8 11 5/8 7 7/ /16 4 7/16 5 1/8 3 1/8 2 3/8 TD / /8 8 9/16 5 9/ /16 4 7/8 5 1/2 3 15/ /16 TD / / /16 7 9/16 9 3/4 6 1/8 6 5/8 5 11/16 5 1/2 20 TD / /4 8 13/ /16 7 3/8 8 1/4 7 3/16 7 Performance TD Model TD x Nom. RPM Volts Max. Watts Speed Inline Mixed Flow Duct Fan CFM v Static Pressure (SP) Ins. WG Ship Schedules: LS HS LS HS LS HS LS HS LS HS Next Day Shipment From Stock Max. SP Duct Dia. Ins LS HS Stock No. TD-100 TD-100x LS HS = High Speed 315 TD HS Performance certified is for installation type D-Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM or RPS) shown is nominal. Performance is based on actual speed of test. TD-125 TD-150 TD-200 TD-250 Soler & Palau USA certifies that the TD range shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. LS = Low Speed

21 TD-MIXVENT Kits FEATURING TD SERIES FANS The TD-MIXVENT fan kits provide all the hardware needed to complete a simple in-line ducted ventilation installation. The kit includes a powerful TD in-line fan, and exterior and interior grilles (with or without lights). Available in both Standard Exhaust Kits, for venting a single location, and Deluxe (Dual) Exhaust Kits, for venting multiple locations with one fan. The TD-MIXVENT fan kit is the ideal solution for any simple in-line ducted fan installation. All TD kits have standard 7-year warranty.* Standard Exhaust Kits KIT-TD100 1 TD100 Exhaust Fan 1 Plastic round grille (PG-100) 1 Air exhaust grille (PER-100W) Integral Mounting Bracket KIT-TD100x 1 TD100x Exhaust Fan 1 Plastic round grille (PG-100) 1 Air exhaust grille (PER-100W) KIT-TD150 1 TD150 Exhaust Fan 1 Plastic round grille (PG-150) 1 Air exhaust grille (PER-150W) Integral Mounting Bracket Lighted Standard Exhaust Kits Deluxe Exhaust Kits KIT-TD150-DV 1 TD150 Exhaust Fan 2 Plastic round grilles (PG-150) 1 Air exhaust grille (PER-150W) 1 Y-fitting (SY-6) Integral Mounting Bracket Lighted Deluxe Exhaust Kits KIT-TD100XL 1 TD100x exhaust fan 1 Vent Light with LED Bulb (VLED-100) Integral mounting bracket MIXED FLOW/CENTRIFUGAL INLINE FANS KIT-TD150L 1 TD150 exhaust fan 2 Vent Lights with LED Bulb (VLED-100) 1 Y-fitting (SY44-6) Integral mounting bracket KIT-TD150H 1 TD150 exhaust fan 2 Vent Lights with Halogen Bulb (VLH-100) 1 Y-fitting (SY44-6) Integral mounting bracket KIT-TD100XH 1 TD100x exhaust fan 1 Vent Light with Halogen Bulb (VLH-100) Integral mounting bracket KIT-TD100XF 1 TD100x exhaust fan 1 Vent Light with Fluorescent Bulb (VLF-100) Integral mounting bracket IMPORTANT: If venting in an noninsulated attic space, or in a cold climate, insulated flexible duct is strongly recommended for condensation issues. KIT-TD150F 1 TD150 exhaust fan Ship Schedules: 2 Vent Lights with Fluorescent Bulb (VLF-100) Next Day Shipment From Stock 1 Y-fitting (SY44-6) Integral mounting bracket *Light Bulbs not included in 7 year warranty. 21

22 22 MIXED FLOW/CENTRIFUGAL INLINE FANS PV INLINE CENTRIFUGAL DUCT FAN APPLICATION The POWER VENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 & 12.4 respectively. All models are designed for direct connection in-line with standard diameter round ducting. Airflow performance values range from 108 CFM (PV-100) up to 942 CFM (PV-315x). CONSTRUCTION Casing Manufactured from high grade pressed galvanized steel, with black baked enamel coating. Extra long inlet and discharge collars make installation quick and trouble free. Supplied with a strong galvanized steel mounting bracket. Easy access prewired junction box. Wheel / Impeller Backward curved centrifugal type. Factory matched to an external rotor motor and dynamically balanced to eliminate vibration. Accessories A wide range of accessories is available to complete the most demanding installation. Available with cord set. DIMENSIONAL DATA Model A B C D E F G Weight lbs PV / /16 4 3/4 7 11/16 7 1/2 4 3/4 9 9/16 7 PV-100x 3 13/ /16 4 3/4 7 11/16 7 1/2 4 3/4 9 9/16 7 PV / /16 4 3/4 7 13/16 7 1/2 4 3/4 9 9/16 7 PV-125x 4 13/ /16 4 3/4 7 13/16 7 1/2 4 3/4 9 9/16 7 PV / /16 4 3/4 8 7/16 9 5/16 4 3/4 13 1/8 11 PV-150x 5 13/ /16 4 3/4 8 7/16 9 5/16 4 3/4 13 1/8 11 PV / /16 4 3/4 8 3/4 9 5/16 4 3/4 13 1/8 11 PV-200x 7 13/ /16 4 3/4 8 3/4 9 5/16 4 3/4 13 1/8 11 PV /4 9 3/4 4 3/4 8 1/16 9 5/16 4 3/4 13 1/8 13 PV-250x 9 3/4 9 3/4 4 3/4 8 1/16 9 5/16 4 3/4 13 1/8 13 PV / /16 4 3/4 9 3/ /16 4 3/ /16 21 PV-315x 12 5/ /16 4 3/4 9 3/ /16 4 3/ /16 21 Performance Model PV Nom. RPM Volts Max. Watts CFM v Static Pressure (SP) Ins. WG Motor Totally enclosed permanent split capacitor start and run external rotor motors. 115V 60Hz (single phase) electrical connection. Permanently sealed, self lubricating precision ball bearings. Safety Thermal Overload Protection Cut-Out (Automatic Reset Type). All Models are suitable for working airstreams up to 140 F Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cul Listed. Independently safety tested by Intertek Laboratories, and are ETL Listed. Independently tested for Airflow Performance. The PV range is licensed to bear the AMCA seal for Air Performance. The PV product range is certified by the Home Ventilating Institute (HVI) for Air Performance. *PV 150x and larger ENERGY STAR qualified. Performance certified is for installation type D-Ducted inlet, Ducted outlet. Performance ratings do not include the effects of Ship Schedules: appurtenances (accessories). Speed (RPM or RPS) shown is nominal. Performance is based on actual speed of test. Next Day Shipment From Stock ALL DIMENSIONS IN INCHES. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. Max. SP Duct Dia. Ins PV x PV-100x PV x PV-125x PV x PV-150x PV x PV-200x PV x PV-250x PV x PV-315x A B E G C F Stock No. D Soler & Palau USA certifies that the PV range shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other random factors. It is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.

23 PV-POWERVENT Kits FEATURING PV SERIES FANS S&P PV-POWERVENT Series fans are also available as easy-to-install kits. This ultra powerful bathroom fan offers a choice of single or dual vent exhaust. These kit are used for installations that require long or complicated duct runs. All PV kits have standard 8-year warranty. Standard Exhaust Kits KIT-PV100 1 PV100 Exhaust Fan 1 Plastic round grille (PG-100) Mounting Bracket KIT-PV100x 1 PV100x Exhaust Fan 1 Plastic round grille (PG-100) Mounting Bracket KIT-PV150 1 PV150 Exhaust Fan 1 Plastic round grille (PG-150) Mounting Bracket Deluxe Exhaust Kits KIT-PV100x-DV 1 PV100x Exhaust Fan 2 Plastic round grilles (PG-100) 1 Y-fitting (SY-4) Mounting Bracket KIT-PV150-DV 1 PV150 Exhaust Fan 2 Plastic round grilles (PG-150) 1 Y-fitting (SY-6) Mounting Bracket KIT-PV200-DV 1 PV200 Exhaust Fan 2 Plastic round grilles (BOR-200) 1 Y-fitting (SY-8) Mounting Bracket MIXED FLOW/CENTRIFUGAL INLINE FANS 23

24 MIXED FLOW/CENTRIFUGAL INLINE FANS SWF SIDEWALL CENTRIFUGAL DUCT FAN Casing Manufactured from high grade pressed galvanized steel, with baked enamel coating. Removable top for easy access to motor for cleaning or inspection. Large grille opening for easy passing of lint and other potentially clogging materials. Includes prewired terminal box. Wheel/Impeller Backward curved centrifugal type. Factory matched to an external rotor motor and dynamically balanced to eliminate vibration. Model A B C C1 C2 D SWF ¼ 13 ¼ / SWF-100x 13 ¼ 13 ¼ / SWF ½ 13 ¼ 10 3/ / SWF-150x 15 ½ 16 1/ /16 2 7/ SWF ½ 16 1/ /16 3 3/8 2 7/ CFM vs. Static Pressure (SP) Ins. WG Model RPM Volts Frequency Current Watts SWF Hz 0.52 A SWF-100X Hz 0.8 A SWF Hz 0.8 A SWF-150X Hz 1.0 A SWF Hz 1.0 A Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other random factors. It is generally accepted that remote mounted venting is quieter than standard (in room) venting. CLOTHES DRYER BOOSTING KITS Accessories A wide range of accessories is available to complete the most demanding installation. Motors Totally enclosed permanent split capacity start and run external rotor motors. 115V 60Hz (single phase) electrical connection. Permanently sealed, self lubricating precision ball bearings. Safety Thermal Overload Protection Cut-Out (Automatic Reset Type). All models are suitable for working airstreams up to 140ºF. Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cul listed. The SWF product range is certified by the Home Ventilating Institute (HVI) for Air Performance. FEATURING PV-100X FANS If you have a dryer with long or complicated duct runs, S&P offers the perfect solution to increase dryer efficiency: the PV-100x Dryer Booster Fan. The PV-100x has been specifically designed to handle dryer boosting applications when overcoming long or complicated duct runs. This system helps save on drying time, moisture build-up, wear and tear on your dryer, and helps save on your electric bill. The centrifugal blade design is able to overcome extreme resistance from the most challenging installations. The PV-100x offers a fully enclosed motor, which ensures a long, trouble free life; thus making it the right choice for enhancing the performance of your clothes dryer. D C1 C2 C B 2mm A 24 PV-100XPS Clothes Dryer Exhaust Booster Kit with Integrated Pressure Sensor Switch This Premium Dryer Booster Kit Includes the Following Components: 1. PV-100x Duct Boosting Fan (153 CFM) with Integrated Pressure Switch 2. Fan Mounting Bracket DBF-100xc Clothes Dryer Exhaust Booster Kit with Current Sensor This Premium Dryer Booster Kit Includes the Following Components: 1. PV-100x Duct Boosting Fan (153 CFM) 2. CS-325 High Current Sensing Switch 3. Fan Mounting Bracket IL-115 (gas) or IL-230 (electric) Clothes Dryer Exhaust Booster Kit with Interlock This Premium Dryer Booster Kit Includes the Following Components: 1. PV-100x Duct Boosting Fan (153 CFM) 2. Interlock 3. Fan Mounting Bracket The PV-100x Dryer Booster fan is suitable for use with duct runs of up to 105 linear feet of 4 rigid duct or a Ship Schedules: maximum of 6 elbows and 80 feet. See page 22 for performance and dimensional data on the PV-100x fan. Next Day Shipment From Stock

25 R SQB SQUARE INLINE BELT DRIVE CENTRIFUGAL DUCT FAN APPLICATION Model SQB square inline duct mounted fans are available in sizes 7 through 24, moving from 100 to over 9,300 CFM, with static pressure capabilities to 1-1/2. SQB units are the perfect selection for clean air applications where space is a leading consideration. The compact housing with removable access doors and side discharge capability can be mounted in any orientation. AMCA licensed performance and UL listing assure that you ve made a reliable selection. CONSTRUCTION Housing Heavy-gauge galvanized steel for extra strength. Integral inlet and outlet duct collars. Universal mounting - horizontal, vertical or any angle. Motor and drives out of the air stream. Easy access for service with removable side panels and drive and bearing covers without disconnecting duct. Centrifugal Wheel All aluminum backward inclined wheel. Nonoverloading for safe operation in ducted systems. Statically and dynamically balanced for smooth operation. Bearings Bearings designed for minimum 200,000 hour life. Bearings are double sealed and prelubricated with relube fittings. DIMENSIONAL DATA SQB A B C Average Ship Wt. Lbs / / / / / / /8 320 Drives Sized for minimum 150% of drive horse power. Machined cast iron adjustable motor pulleys. Motor mount plate with integral belt tensioning device. Nonstatic v-belts. Motors Single speed open drip-proof are standard. All motors are rated for continuous duty. Standard motors are permanently sealed ball bearing type. 182T and larger motors shipped unmounted for field installation. AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models SQB shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. UL-705 LISTED POWER VENTILATOR Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment MIXED FLOW/CENTRIFUGAL INLINE FANS ACCESSORIES SQB GRAVITY DAMPER DAMPER MOTOR (LOOSE) MOTOR SAFETY GUARD VIBRATION ISOLATORS HANGING STYLE VIBRATION ISOLATORS FLOOR MOUNT FAN LESS MOTOR & DRIVE OD STOCK NO. STOCK NO. STOCK NO. RUBBER STOCK NO. SPRING STOCK NO. RUBBER STOCK NO. SPRING STOCK NO. STOCK NO MGSQB7812 VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ06-20 SQB07LMDS MGSQB7812 VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ06-20 SQB08LMDS MGSQB10 VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ06-20 SQB10LMDS MGSQB7812 VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ06-20 SQB12LMDS MGSQB15 VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ06-20 SQB15LMDS MGSQB18 VHRSQ18-20 VHSSQ06-20 VFRSQ18-20 VFSSQ06-20 SQB18LMDS MGSQB2024 VHRSQ18-20 VHSSQ06-20 VFRSQ18-20 VFSSQ06-20 SQB20LMDS MGSQB2024 VHRSQ24-30 VHSSQ24 VFRSQ24-30 VFSSQ24-30 SQB24LMDS (1) - MAXIMUM 3 HP MOTOR - FOR 5 HP MOTOR CONTACT FACTORY ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 25

26 MIXED FLOW/CENTRIFUGAL INLINE FANS SQB SQB MOTOR Hp 1/4 1/4 1/3 1/4 1/4 1/3 1/2 1/4 1/3 1/2 3/4 1/4 1/3 1/2 3/4 1 Square Inline Belt Drive Centrifugal Duct Fan Ventilator with Open Drip-proof Motor and Drive Assembly MAX CFM at Static Pressure 115/1/60* /460/3/60 RPM BHp 1/2 SP 1/8 1/4 3/8 1/2 3/ /4 1 1/2 STOCK NO. STOCK NO SQB07ML1S SQB07ML3S SQB07MH1S SQB07MH3S SQB07PH1S SQB07PH3S SQB08ML1S SQB08ML3S SQB08MH1S SQB08MH3S SQB08PH1S SQB08PH3S SQB08QH1S SQB08QH3S SQB10MH1S SQB10MH3S SQB10PH1S SQB10PH3S SQB10QH1S SQB10QH3S SQB10RH1S SQB10RH3S SQB12MH1S SQB12MH3S SBQ12PH1S SQB12PH3S SQB12QH1S SQB12QH3S SQB12RH1S SQB12RH3S SQB12SH1S SQB12SH3S Performance certified is for installation Type B-free inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. Performance at higher RPM for each horse power is standard for that unit. Reduced performance can be obtained down to the minimum shown at the lower RPM for each unit, by resetting the adjustable motor sheave. *Tri-voltage ( ) is standard on 3/4 through 1 1/2 Hp Single phase motors. Tri-voltage is available for the 1/2 Hp motors. Inquire for price and delivery. 26

27 SQB SQB MOTOR Hp 1/4 1/3 1/2 3/ /2 1/3 1/2 3/ /2 2 1/3 1/2 3/ /2 2 1/2 3/ /2 2 3 MAX BHp RPM 1/2 SP Square Inline Belt Drive Centrifugal Duct Fan Performance certified is for installation Type B-free inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Ventilator with Open Drip-proof Motor and Drive Assembly CFM at Static Pressure 115/1/60* /460/3/60 1/8 1/4 3/8 1/2 3/ /4 1 1/2 STOCK NO. STOCK NO SQB15MH1S SQB15PH1S SQB15QH1S SQB15RH1S SQB15SH1S SQB15TH1S SQB18PH1S SQB18QH1S SQB18RH1S SQB18SH1S SQB18TH1S SQB18VH1S SQB20PH1S SQB20QH1S SQB20RH1S SQB20SH1S SQB20TH1S SQB20VH1S SQB24QH1S SQB24RH1S SQB24SH1S SBQ24TH1S SQB24VH1S N/A SQB15MH3S SQB15PH3S SQB15QH3S SQB15RH3S SQB15SH3S SQB15TH3S SQB18PH3S SQB18QH3S SQB18RH3S SQB18SH3S SQB18TH3S SQB18VH3S SQB20PH3S SQB20QH3S SQB20RH3S SQB20SH3S SQB20TH3S SQB20VH3S SQB24QH3S SQB24RH3S SQB24SH3S SQB24TH3S SQB24VH3S SQB24WH3S MIXED FLOW/CENTRIFUGAL INLINE FANS The sound ratings shown are loudness values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. Performance at higher RPM for each horse power is standard for that unit. Reduced performance can be obtained down to the minimum shown at the lower RPM for each unit, by resetting the adjustable motor sheave. *Tri-voltage ( ) is standard on 3/4 through 1 1/2 Hp Single phase motors. Tri-voltage is available for the 1/2 Hp motors. Inquire for price and delivery. 27

28 R SQD SQUARE INLINE DIRECT DRIVE CENTRIFUGAL DUCT FAN MIXED FLOW/CENTRIFUGAL INLINE FANS APPLICATION Model SQD square inline duct mounted fans are available in sizes 6 through 15, moving up to 2,800 CFM, with static pressure capabilities to 1. SQD units are the perfect selection for clean air applications where space is a leading consideration. The compact housing with removable access doors and side discharge capability can be mounted in any orientation. AMCA licensed performance and UL listing assure that you have made a reliable selection. CONSTRUCTION Housing Heavy-gauge galvanized steel for extra strength. Integral inlet and outlet duct collars Universal mounting - horizontal, vertical or any angle. Easy access for service with removable side panels, without disconnecting duct. Centrifugal Wheel All aluminum backward inclined wheel. Nonoverloading for safe operation in ducted systems. Statically and dynamically balanced for smooth operation. SQD 06 has composite wheel. DIMENSIONAL DATA SQD A B C Average Ship Wt. Lbs / / / / /8 120 Motors Single speed totally enclosed are standard. All motors are rated for continuous duty. Standard motors are permanently sealed ball bearing type. SQD06 has an external rotor motor. AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models SQD shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. UL-705 LISTED POWER VENTILATOR ACCESSORIES SQD DAMPER SPEED CONTROL DAMPER MOTOR (LOOSE) OD STOCK NO. STOCK NO. VIBRATION ISOLATORS HANGING STYLE RUBBER STOCK NO. SPRING STOCK NO MAX 1/3 HP-5 AMP 120V MAX 1/2 HP-10 AMP 120V VIBRATION ISOLATORS FLOOR MOUNT RUBBER STOCK NO. SPRING STOCK NO. 5 AMP STOCK NO. SPEED CONTROL 115/1/60 230/1/60 10 AMP STOCK NO. STOCK NO VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ N/A N/A VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ N/A VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ VHRSQ06-15 VHSSQ06-20 VFRSQ06-15 VFSSQ06-20 N/A Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment 28 ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.

29 SQD SQD 60 MOTOR Hp 100 WATT MAX BHp.95 MAX 115/60/ / / / / / / / Square Inline Direct Drive Centrifugal Duct Fan Ventilator with Totally Enclosed Motor RPM SONES CFM at Static Pressure 115/1/60* 1/4 SP 1/8 1/4 3/8 1/2 5/8 3/4 1 STOCK NO. STOCK NO SQD601AS N/A * SQD81251AS N/A 1070* SQD8251AS SQD8251CS * SQD10251AS SQD10251CS 1150* SQD10501AS SQD10501CS * SQD12251AS SQD12251CS * SQD12501AS SQD12501CS * SQD15501AS SQD15501CS * MIXED FLOW/CENTRIFUGAL INLINE FANS * True motor speed - other speeds based on speed control use. Performance certified is for installation Type B-free inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. Use 5 AMP Speed Control for motors 1/3 HP and smaller. Use 10 AMP Speed Control for motors 1/2. 29

30 RECOVERY VENTILATORS TR TOTAL RECOVERY FOR ALL CLIMATES THE ULTIMATE ERV S&P s TRs moderate extremes in both temperature and humidity, creating a comfortable indoor environment. The unique moisture transfer capability of the S&P core also eliminates condensation and frost build up in most applications. No mechanical or electrical defrost systems are needed, which means higher heat recovery efficiencies, easier installation and more reliable operation. Standard Features MERV-8 filters Less than 1 watt stand-by power consumption Transformer/relay package allowing simple on/off control Plastic double collars for 6 or 8 direct duct connection (TR300 is 8 only) 3 power cord Integral mounting flange and hanging bracket system Fully insulated case Large cores for high efficiency No condensate pan or drain required 10-year industry best core warranty 2-year warranty on balance of unit Performance and Dimensions Model ESP (Inches H 2 O) Specifications TR70 TR130 TR200 TR300 Ship Schedules: LISTED DUCTED HEAT RECOVERY VENTILATOR 89S5 Next Day Shipment From Stock Airflow (CFM) Watts Electrical: 120 V, 60 Hz, Single Phase, 1.0 FLA, contains one 0.1 hp motor Temp Eff % Dimensions: unit case=25-1/8w x 20-1/8H x 10-1/8D Total Winter % carton=21w x 29-1/2L x 15H Weight: Total Summary % unit=44 lbs, in carton=52 lbs Airflow (CFM) Watts Electrical: 120 V, 60 Hz, Single Phase, 1.3 FLA, contains one 0.1 hp motor Temp Eff % Dimensions: unit case=28-3/4w x 20-1/8H x 13D, Total Winter % carton=21w x 32L x 17-1/2H Weight: Total Summary % unit=58 lbs, in carton=65 lbs Airflow (CFM) Watts Electrical: 120 V, 60 Hz, Single Phase, 1.5 FLA, contains one 0.1 hp motor Temp Eff % Dimensions: unit case=28-3/4w x 20-1/8H x 23-7/8D Total Winter % carton=21-1/2w x 32L x 29H Weight: Total Summary % unit=80 lbs, in carton=88 lbs Airflow (CFM) Watts Electrical: 120 V, 60 Hz, Single Phase, 3.3 FLA, contains one 0.2 hp motor Temp Eff % Dimensions: unit case=28-3/4w x 20-1/8H x 23-7/8D Total Winter % carton=21-1/2w x 32L x 29H Weight: Total Summary % unit=72 lbs, in carton=85 lbs TR Controls Stock No. Control Description SPTL Percentage Timer Control Runs unit an adjustable amount of time each hour Two wire, low voltage connection to TR SPBL SFM Push Button Point-of-Use Control Percentage Timer Control with Furnace Interlock Push button control turns on unit from bathrooms or other intermittent exhaust locations 20 minute run-time with one touch Push 2x for 40 or 3x for 60 minutes Two wire, low voltage connection to PTL Wires to TRV unit and either thermostat or furnace control to turn on furnace blower Six wire, low voltage connection 30

31 UBS UPBLAST BELT DRIVE PROPELLER ROOF EXHAUSTER APPLICATION Model UBS is a high capacity roof mounted exhauster rated from 7,000 to 51,000 CFM. They are general ventilation units designed to economically remove large volumes of air, fumes and vapors from commercial and industrial buildings such as warehouses, manufacturing and assembly plants, chemical plants, foundries and paper mills. Straight-through air flow design results in maximum exhaust efficiency. During operation, the high air flow velocity opens butterfly dampers and helps prevent rain or snow from entering. Dampers close and cover the venturi opening when unit is not in use. The roof mounted location eliminates interference with processes and equipment inside the building. It also permits locating the exhauster over a source of heated or contaminated air, allowing direct upward venting to the outside, unlike wall mounted exhausters which may move contaminated air through adjacent work spaces. Belt drive units usually operate more quietly and afford easier performance adjustments, while direct drive models require less maintenance. CONSTRUCTION Panel Assembly Heavy-gauge G90 galvanized steel panel on all sizes. One piece venturi for maximum efficiency. Welded and bolted support structure of schedule 40 galvanized pipe. Motor/bearing plates of minimum 10 gauge galvanized steel. Lifting eyes standard for ease of installation. Propeller Steel hub plate with steel taper lock bushing. Die formed, heavy gauge, epoxy coated, steel blades. DIMENSIONAL DATA UBS A B C D E F METAL GAUGES WIND SHROUD FAN PANEL LISTED POWER ROOF VENTILATOR UL STANDARD 705 Average Ship Wt. Lbs A - Outside Diameter of Windband. B - Height of Unit Above Curb Cap. C - Maximum Depth of Unit Below Top of Curb, Actual Depth Varies with Motor Size. ACCESSORIES UBS RECOMMENDED 12 HIGH MOUNTING CURB D - Inside Dimension of Square Curb Cap. E - Minimum Inside Dimension of Curb Opening Required for Adequate Clearance of Fan Frame. F - Outside Dimension of Factory Built Prefab Curb. CUSHION CLOSE MOTOR SAFETY RETAINING CHAIN OD STOCK NO. STOCK NO. STOCK NO UBB UBB UBB UBB UBB UBB UBB Windband/Butterfly Dampers Heavy-gauge galvanized steel windband. Galvanized steel butterfly dampers standard. Galvanized rain channel drains water from damper area to roof. Corrosion resistant. Drives Sized for minimum 150% of drive horsepower. Single belt adjustable pitch sheaves through 3 HP. Two belt fixed pitch sheaves on 5 HP and 7 1/2 HP units. Adjustable tension rods for belt adjustment. Nonstatic oil resistant v-belts. Keyed, turned, ground and polished shafts. Bearings Bearings designed for minimum 200,000 hour life. Cast iron self-aligning pillow block ball bearings. Bearings are sealed, prelubricated with relube fittings. Motors Brands are nationally recognized and locally serviced. Open drip-proof construction is standard. Ship Schedules: 3 Day Shipment From Stock 10 Day Shipment ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. PROPELLER ROOF VENTILATORS 31

32 PROPELLER ROOF VENTILATORS UBS UBS MOTOR Hp MAX BHp RPM 1/4 SP NO. OF BLADES Upblast Belt Drive Propeller Roof Exhauster Ventilator with Open Drip-proof Motor and Drive Assembly 208- CFM at Static Pressure 115/208/230/1/60* 230/460/3/60 0 1/8 1/4 3/8 1/2 STOCK NO. STOCK NO UBS24SH1S UBS24SH3S UBS30SH1S UBS30SH3S / UBS30TH1S UBS30TH3S UBS30VH1S UBS30VH3S UBS36SH1S UBS36SH3S / UBS36TH1S UBS36TH3S UBS36VH1S UBS36VH3S N/A UBS36WH3S 1 1/ UBS42TH1S UBS42TH3S UBS42VH1S UBS42VH3S N/A UBS42WH3S N/A UBS42XH3S UBS48VH1S UBS48VH3S N/A UBS48WH3S N/A UBS48XH3S N/A UBS54WH3S N/A UBS54XH3S N/A UBS60XH3S 7 1/ N/A UBS60YH3S Performance shown is for roof ventilators for installation type A: Free inlet, Free outlet. The power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. Sound ratings are loudness values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. For additional sound data and for selections at other static pressures, please refer to the Optisizer Selection Program. Due to air stream cooling, the motor loading into the service factor shown does not overheat the motor and is within NEMA recommended limits. BHP at most static pressure points is less than the maximum power shown - in many cases substantially less. Use Optisizer to see the exact BHP for your selection. 32

33 ARE/ARS DOME DIRECT DRIVE PROPELLER EXHAUST/INTAKE ROOF FAN ARE=Exhaust ARS=Supply APPLICATION The AR series offers powerful axial intake (ARS) or exhaust (ARE) performance in a roof mount design that is compact, lightweight and easy to install. The AR series is an excellent choice for factories, shops, restaurants, bathrooms, offices, schools and other similar applications where light to moderate static pressures are present. The low contour designs and all aluminum housing provides a modern, clean appearance in addition to excellent performance and durability. The direct drive design has no belts or fan bearings to maintain or adjust and consequently requires very little maintenance. CONSTRUCTION Housing Heavy-gauge all aluminum housing. Exclusive U-Spring suspension compensates for both radial and lateral movement and provides 44% better vibration isolation than rubber isolators. External wiring chase for easy connection. Quick access to motor compartment for easy maintenance. Propeller Attaches directly to motor shaft for maximum efficiency. Precision pitched, heavy-gauge aluminum blades with steel hub. Blades are designed for specific exhaust or supply requirements. Speed Controllable Motor Standard motors are single speed, speed controllable and drip-proof. All motors are rated for continuous duty. Disconnect is standard on ODP motors. Motors are shipped assembled with factory test run assurance. ACCESSORIES Solid State Speed Control: Is matched to the motor and blower wheel to allow continuous reduction in performance allowing adjustments of airflow for system balancing. CFM is reduced in direct proportion to motor speed reduction. Speed control is only available for single phase. Exhauster performance can be controlled from the ventilated area. PERFORMANCE ASSURANCE Units are tested in accordance with AMCA 301 (Sound) and AMCA 210 (Air). LISTED POWER ROOF VENTILATOR UL STANDARD 705 PROPELLER ROOF VENTILATORS DIMENSIONAL DATA ARE/ARS A B C D E F Average Ship Wt. Lbs / / / / / /4 75 Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment ACCESSORIES ARE/ARS ARE=Exhaust RECOMMENDED 12 MOUNTING CURB ARS=Supply RECOMMENDED DAMPER DAMPER MOTOR (LOOSE) 115 VOLT SPEED CONTROL 230 VOLT SPEED CONTOL OD STOCK NO. OD STOCK NO. ARE / ARS STOCK NO. ARE / ARS STOCK NO. STOCK NO / / S3GA12CB / MP / / S3GA16CB / MP / / S3GA20CB / MP / / S3GA24CB / MP SPEED CONTROL MAX 1/3 HP-5 AMP 120V ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 33

34 PROPELLER ROOF VENTILATORS ARE ARE MOTOR Hp MAX BHp / / / / / / * AS RUN SPEED + PERFORMANCE USING SPEED CONTROL* ARS ARS MOTOR Hp MAX BHp 10 1/ / / / / / * AS RUN SPEED + PERFORMANCE USING SPEED CONTROL Dome Direct Drive Propeller Exhaust Roof Fan Ventilator with Open Drip-proof Motor SONES CFM at Static Pressure 115/1/ /1/60 0 SP 0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 STOCK NO. STOCK NO ARE10IH1AS N/A 1550* ARE12MM1AS ARE12MM1CS 1140* ARE12MH1AS ARE12MH1CS 1725* ARE16MM1AS ARE16MM1CS 1140* ARE16PH1AS ARE16PH1CS 1725* ARE20MM1AS ARE20MM1CS 1140* Dome Direct Drive Propeller Supply Roof Fan Ventilator with Open Drip-proof Motor SONES CFM at Static Pressure 115/1/ /1/60 0 SP 0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 STOCK NO. STOCK NO ARS10IH1AS N/A 1550* ARS12MM1AS ARS12MM1CS 1140* ARS12MH1AS ARS12MH1CS 1725* ARS16MM1AS ARS16MM1CS 1140* ARS16PH1AS ARS16PH1CS 1725* ARS20MM1AS ARS20MM1CS 1140* Soler & Palau certifies the performance shown herein. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 210 (Air) and AMCA 300 (Sound). Use 5 AMP Speed Control for motors 1/3 HP and smaller. 34

35 WA & DA COMPACT WALL AND DUCT AXIAL FAN APPLICATION The S&P COMPACT WALL and DUCT AXIAL FANS feature, as the name suggests, an extremely compact design created by the combination of an external rotor motor matched with a direct drive wrap around an impeller hub. This very low profile design optimizes airflow performance while minimizing noise generation. Both wall and duct mounted versions require an absolute minimum depth for any given wall, ceiling, panel or in-line duct mounted installation. The S&P COMPACT WALL AXIAL FANS are designed to be installed directly into side walls, ceilings and panels in order to exhaust or supply air to the surrounding environments. The S&P COMPACT DUCT AXIAL FANS are designed to be installed in-line with inducted or partially ducted ventilation systems for exhaust or supply air applications. CONSTRUCTION Motor All models include asynchronous induction capacitor run and start motors. Constructed from die cast aluminum and finished in a black polyester paint coating. 100% Speed controllable. Totally enclosed IP/65 protection. Class F insulation. Suitable working temperatures -40 C (-40 F) up to 60 C (140 F). All models include a Safety Auto Reset Thermal Overload Protection. DIMENSIONAL DATA Wall Axial (WA) J H G D F Duct Axial (DA) B E A B C E Terminal Box Manufactured from high impact grade aluminum. IP65 protected. Wheel / Impeller Manufactured from glass filled UV resistant polyamide. Special Order: Die cast aluminum. Please inquire. Corrosion and weather resistant. Accessories A wide range of accessories is available to complete the most demanding installation. Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc and are UL and cul Listed. Model A B C D E F G H J Weight lbs(kgs) WA / / /16 3/ /16 2 7/8 1 1/4 2 1/2 15 WA / / / /4 3/8 16 5/8 3 1/16 1 5/8 2 1/2 20 WA / /4 15 3/4 17 3/4 3/8 18 3/4 3 3/4 1 5/8 2 1/2 29 WA / /8 17 3/ /16 3/8 21 1/8 3 7/8 1 3/4 2 1/2 34 PROPELLER WALL/DUCT FANS A C Model A B C D E Weight (lbs) DA / / /16 3/8 22 DA / /4 6 11/ /4 1/2 31 DA / /16 7 1/8 17 3/4 1/2 40 DA / /16 7 1/ /16 1/2 49 ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 35

36 R Air & Sound Performance WA (STOCK #) *TECHNICAL SPECIFICATION INPUT WATTS PEAK BHP RPM Compact Wall Axial Fan CFM v Static Pressure (SP) Ins. WG WA 12 HCGB/4-12/G-A WA 16 HCGB/4-16/G-A WA 18 HCGB/4-18/G-A WA 20 HCGB/4-20/G-A SONES WA Compact Duct Axial Fan (STOCK #) *TECHNICAL SPECIFICATION INPUT WATTS PEAK BHP RPM CFM v Static Pressure (SP) Ins. WG SONES DA 12 TCGB/4-12/G-B DA 16 TCGB/4-16/G-B DA 18 TCGB/4-18/G-B DA 20 TCGB/4-20/G-B Performance certified is for installation type A: free inlet, free outlet. PROPELLER WALL/DUCT FANS Performance is shown for Soler & Palau USA WALL & DUCT AXIAL FANS. Speed (rpm) shown is nominal. Performance is based on actual speed of the test. Performance ratings include the effects of finger guards in the airstream. The sound ratings are loudness values in fan sones at 5ft (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. *Technical Specifications: Example HCGB/ 4-16/ G-A 1) HC: TC: a a a x 2) G: B: 3) B: T: 5) 16: 6) A: a a a a COMPACT WALL AXIAL FAN reference. COMPACT DUCT AXIAL FAN reference. Plastic adjustable impeller (supplied as standard). Aluminum adjustable impeller (please inquire). Single Phase Motor. 120 V 60 Hz. Three Phase Motor. 220/460 V 60 Hz (please inquire). Speed. Number of poles. Nominal blade diameter in inches. Air direction. Form A = air over motor-impeller. Form B = air over-impeller motor. SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models WA & DA shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. Ship Schedules: Next Day Shipment From Stock 36

37 CSTR SHUTTER FANS FEATURE AND BENEFITS Totally assembled Motor is totally enclosed maintenance free, high efficiency, sealed ball bearings and UL/ULC certified Corrosion resistant aluminum shutter with tie bar to reduce shutter flapping and opening on windy days One year limited warranty Safety chrome grille on intake side meets OSHA standards. Fan must be mounted 7 above ground level on the exhaust side Includes cord on 12 only (STOCK #) SIZE SPD HP RPM HZ Ph CFM at Static Pressure Hi/Lo Hi/Lo Hi/Lo Hi/Lo CFM per SP CSTR-12C 12 VAR 1/ / / / /300 11/9 CSTR VAR 1/ / / / /550 15/13 CSTR VAR 1/ / / / / /14 CSTR VAR 1/ / / / / /14 VOLTS AMPS Hi/Lo DRIVE BLADE CORD WT./ LBS. LxWxH CSTR-12C DD 3-Alum x 16 x 13 CSTR / /0.05 DD 3-Alum No x 20 x 13 CSTR / /1.7 DD 3-Alum No x 24 x 13 CSTR / /2.4 DD 3-Alum No x 28 x 14.5 PROPELLER WALL/DUCT FANS Fan Size Rough Opening Size Recommended Inlet Size (Sq. Ft.) x x x x Ship Schedules: Next Day Shipment From Stock ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 37

38 GED SIDEWALL DIRECT DRIVE PROPELLER FAN APPLICATION GED wall propeller fans feature the maximum efficiency, low maintenance and durable, economical operation resulting from the direct drive design. It is available in exhaust configurations to provide general ventilation for a wide variety of buildings and enclosed areas within buildings. Examples include factories, assembly plants, churches, gymnasiums, garages, jails, machine rooms and many others. PROPELLER WALL/DUCT FANS They feature extremely quiet operation and an integral motor side guard as standard. CONSTRUCTION Panel Assembly 16 gauge galvanized steel. One piece spun venturi for maximum efficiency. Prepunched mounting holes for easy installation. Formed flanges for added rigidity. Integral OSHA approved motor side guard. Propeller Attached directly to motor shaft for maximum efficiency. Precision pitched, fabricated aluminum blades (3 & 4 blade models). Polypropylene blades (6 blade models). Statically and dynamically balanced. DIMENSIONAL DATA DIMENSIONS (IN.) GED A B C D E* F* Average Ship Wt. Lbs / / / / / / A. Outside dimension of square panel. B. Diameter of venturi. C. Width of flange, 1" for all models. D. Depth of venturi, 2" for all models. E. Depth of fan (exhaust). F. Depth of fan (supply). * Varies with motor selection. Motors Permanently lubricated sealed ball bearing type. Sleeve bearings on low HP models. Open drip-proof construction is standard. Entire Fan Unit Suitable for all angle installation. Completely assembled and factory tested prior to shipment. UL STANDARD 705 ACCESSORIES GED GRAVITY DAMPER STOCK NO. DAMPER MOTOR (LOOSE) STOCK NO. 115 VOLT SPEED CONTROL 5 AMP STOCK NO. 10 AMP STOCK NO. 10 EAS12 EAS1232MTR N/A 12 EAS12 EAS1232MTR N/A 14 EAS16 EAS1232MTR EAS16 EAS1232MTR N/A 18 EAS20 EAS1232MTR EAS20 EAS1232MTR Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock SPEED CONTROL MAX 1/3 HP-5 AMP 120V MAX 1/2 HP-10 AMP 120V 38 ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE SHUTTER DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.

39 GED GED MOTOR Hp RPM NO. OF BLADES 0 FT. Sidewall Direct Drive Propeller Fan Ventilator with Open Drip-proof Motor CFM/BHp at Static Pressure 115/1/60 0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 STOCK NO. 10 1/ / / / / / / / /.11 GED10JH1AS 12 1/ / / / / / / GED12JH1AS 1/ / / / / / / / /.27 GED12MH1AS 14 1/ / / / / / / GED14MH1AS 1/ / / / / / / / /.50 GED14QH1AS 16 1/ / / / / / / GED16MM1AS 1/ / / / / / / /.39 - GED16PH1AS 1/ / / / / / / /.28 - GED18MM1AS 18 1/ / / / / / / / /.37 GED18MH1AS 1/ / / / / / / / /.55 GED18QH1AS 1/ / / / / / GED20MM1AS 20 1/ / / / / / / / /.53 GED20QH1AS Performance shown is for Model GED without inlet or outlet ducts. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for free inlet fan sone levels. Fans use 3 & 4 blade fabricated aluminum propellers. ASSEMBLED WALL HOUSING PACK - EXHAUST ASSEMBLED FAN/WALL HOUSING/DAMPER/OSHA GUARD PROPELLER WALL/DUCT FANS GED A B PACK WITH GRAVITY DAMPER STOCK NO. PACK WITH MOTORIZED DAMPER STOCK NO WHPGED1012 WHPGED1012M WHPGED1012 WHPGED1012M WHPGED1416 WHPGED1416M WHPGED1416 WHPGED1416M WHPGED1820 WHPGED1820M WHPGED1820 WHPGED1820M 39

40 LCE/LCS SIDEWALL BELT DRIVE PROPELLER FAN LCE=Exhaust LCS=Supply APPLICATION Model LCE (exhaust) and LCS (supply) are high capacity belt driven propeller fans. Their primary application is the exhaust or supply of large volumes of air at relatively low static pressures from commercial, light industrial and agricultural buildings such as manufacturing and assembly plants, warehouses, parking garages, gymnasiums, equipment rooms, distribution centers, poultry and greenhouses. Drives Sized for minimum 150% of drive horsepower. Single belt adjustable pitch sheaves through 3 HP. Nonstatic v-belts. Belt driven fans provide large volumes of air at low fan speeds and low noise levels and afford quick, easy performance adjustments. When suspended from the ceiling, thus keeping floor spaces open, model LC can be installed to direct large volumes of air downward toward work centers improving employee comfort and productivity. Bearings Designed for minimum 200,000 hour life. Bearings are sealed, prelubricated with relube fittings. PROPELLER WALL/DUCT FANS CONSTRUCTION Motors Open drip-proof construction is standard. All motors mounted and factory run tested. Panel Assembly Heavy-gauge galvanized steel. All welded motor & drive support frame assembly. Prepunched mounting holes. Soler & Palau USA, certifies that the Models LC shown herein are licensed to bear the AMCA Seal. The ratings SOUND shown are based on test and procedures and performed in accordance with AMCA PERFORMANCE Publication 211 and AMCA Publication MOVEMENT 311 and comply with the requirement of AND CONTROL ASSOCIATION the AMCA Certified Ratings Program. INTERNATIONAL, INC. Propeller Die formed galvanized steel blades. Epoxy coated hub keyed to fan shaft. Statically and dynamically balanced. R UL STANDARD 705 DIMENSIONAL DATA FAN LESS MOTOR & DRIVES LC A B C Avg. Ship Wt. Lbs LCE20LMDS 3/ LCE24LMDS 1 1/ LCE30LMDS 1 1/ LCE36LMDS LCE42LMDS LCE48LMDS LCE54LMDS LCE60LMDS 3 STOCK NO. MAX MOTOR Hp ACCESSORIES RECOMMENDED DAMPER* (EXHAUST) LC OD STOCK NO. DAMPER MOTOR (LOOSE) STOCK NO. WALL WALL HOUSING WALL HOUSING PACK PACK WITH HOUSING PACK WITH GRAVITY MOTORIZED WITH GRAVITY DAMPER DAMPER DAMPER (EXHAUST)* (EXHAUST)* (SUPPLY)* STOCK NO. STOCK NO. STOCK NO. RAINHOOD (EXHAUST)* RAINHOOD (SUPPLY)* RAINHOOD BIRDSCREEN (EXHAUST)* RAINHOOD BIRDSCREEN (SUPPLY)* STOCK NO. STOCK NO. STOCK NO. STOCK NO /2 EAS20 EAS1232MTR WHPLCE20 WHPLCE20M WHPLCS KDS KDS RHS RHS /2 EAS26 EAS1232MTR WHPLCE24 WHPLCE24M WHPLCS KDS KDS RHS RHS /2 EAS32 EAS1232MTR WHPLCE30 WHPLCE30M WHPLCS KDS KDS RHS RHS /2 EAS38 EAS3850MTR WHPLCE36 WHPLCE36M WHPLCS KDS KDS RHS RHS /2 EAS44 EAS3850MTR WHPLCE42 WHPLCE42M WHPLCS KDS KDS RHS RHS /2 EAS50 EAS3850MTR WHPLCE48 WHPLCE48M WHPLCS KDS KDS RHS RHS /2 EAS56 EAS5662MTR WHPLCE54 WHPLCE54M WHPLCS KDS KDS RHS RHS /2 EAS62 EAS5662MTR WHPLCE60 WHPLCE60M WHPLCS KDS KDS RHS RHS * Refer to pages 65 & 66 for dimensions ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE SHUTTER DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 40

41 LC Model LC Motor Hp Max BHp RPM 0 SP Sidewall Belt Drive Propeller Fan CFM at Static Pressure 115/1/60* 0 1/10 1/8 1/4 3/8 1/2 Ventilator with Open Drip-proof Motor and Drive Assembly /460/3/60 STOCK NO. (LCE-Exhuast)* STOCK NO. (LCE-Exhuast)* 1/ LCE20MH1S LCE20MH3S 1/ LCE20PH1S LCE20PH3S 1/ LCE20QH1S LCE20QH3S 3/ LCE20RH1S LCE20RH3S 1/ LCE24MH1S LCE24MH3S 1/ LCE24PH1S LCE24PH3S 1/ LCE24QH1S LCE24QH3S 3/ LCE24RH1S LCE24RH3S LCE24SH1S LCE24SH3S 1 1/ LCE24TH1S LCE24TH3S 1/ LCE30MH1S LCE30MH3S 1/ LCE30PH1S LCE30PH3S 1/ LCE30QH1S LCE30QH3S 3/ LCE30RH1S LCE30RH3S LCE30SH1S LCE30SH3S 1 1/ LCE30TH1S LCE30TH3S 1/ LCE36PH1S LCE36PH3S 1/ LCE36QH1S LCE36QH3S 3/ LCE36RH1S LCE36RH3S LCE36SH1S LCE36SH3S 1 1/ LCE36TH1S LCE36TH3S LCE36VH1S LCE36VH3S 1/ LCE42PH1S LCE42PH3S 1/ LCE42QH1S LCE42QH3S 3/ LCE42RH1S LCE42RH3S LCE42SH1S LCE42SH3S 1 1/ LCE42TH1S LCE42TH3S LCE42VH1S LCE42VH3S 1/ LCE48QH1S LCE48QH3S 3/ LCE48RH1S LCE48RH3S LCE48SH1S LCE48SH3S 1 1/ LCE48TH1S LCE48TH3S LCE48VH1S LCE48VH3S 3/ LCE54RH1S LCE54RH3S LCE54SH1S LCE54SH3S 1 1/ LCE54TH1S LCE54TH3S LCE54VH1S LCE54VH3S N/A LCE54WH3S LCE60SH1S LCE60SH3S 1 1/ LCE60TH1S LCE60TH3S LCE60VH1S LCE60VH3S N/A LCE60WH3S Performance ratings include the effects of appurtenances (accessories). Power ratings (BHP) do not include transmission losses. Performance certified is for installation type A-free inlet, free outlet. The sound ratings shown are loudness values in fan 5 (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. *Tri-voltage ( ) is standard on 3/4 through 1 1/2 Hp Single phase motors. Tri-voltage is available for the 1/2 Hp motors. Inquire for price and delivery. PROPELLER WALL/DUCT FANS NOTES: *Stock Numbers shown are for LCE-Exhaust fans, for LCS-Supply fans replace the E with S. Example: LCE-Exhaust = LCE20MH1S LCS-Supply = LCS20MH1S Ship Schedules: Next Day Shipment From Stock 3 Day Shipment From Stock 10 Day Shipment LCS-Supply fans have a 10-day ( ) ship schedule 41

42 R L2 HEAVY DUTY SIDEWALL BELT DRIVE PROPELLER FAN APPLICATION Model L2E (exhaust) is a heavy duty construction level 2 high capacity wall mounted belt driven propeller fan. Its primary application is the exhaust of large volumes of ventilation air from commercial and light industrial buildings such as manufacturing and assembly plants, warehouses, parking garages, gymnasiums, equipment rooms, distribution centers and OEM applications. PROPELLER WALL/DUCT FANS Wall mounting provides an easy, and economical installation. Belt driven fans provide large volume of air at low fan speed and low noise levels and afford quick, easy performance adjustments. CONSTRUCTION Panel Assembly Heavy-gauge galvanized steel. All welded motor & drive support frame assembly. Prepunched mounting holes. Propeller Die formed galvanized steel blades. Lamination reinforced blades for 3 HP and up. Epoxy coated hub keyed to fan shaft. Statically and dynamically balanced. Drives Sized for minimum 150% of drive horsepower. Single belt adjustable pitch sheaves through 3 HP. Two belt fixed pitch sheaves 5 HP and up. Nonstatic v-belts. Bearings Designed for minimum 200,000 hour life. Bearings are sealed, prelubricated with relube fittings. Motors Open drip-proof construction is standard. All motors mounted and factory run tested. SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models L2 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. UL STANDARD 705 Ship Schedules: Next Day Shipment From Stock 10 Day Shipment DIMENSIONAL DATA L2 A B C AvG. Ship Wt. Lbs ACCESSORIES RECOMMENDED DAMPER* DAMPER MOTOR (LOOSE) WALL HOUSING WITH GRAVITY DAMPER PACK* WALL HOUSING PACK WITH MOTORIZED DAMPER* OD STOCK NO. STOCK NO. STOCK NO. STOCK NO /2 EAS26 EAS1232MTR WHPL2E24 WHPL2E24M /2 EAS32 EAS1232MTR WHPL2E30 WHPL2E30M /2 EAS38 EAS3850MTR WHPL2E36 WHPL2E36M /2 EAS44 EAS3850MTR WHPL2E42 WHPL2E42M /2 EAS50 EAS3850MTR WHPL2E48 WHPL2E48M * Refer to pages 65 & 66 for dimensions 42 ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE SHUTTER DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.

43 L2 LC MOTOR Hp MAX BHp RPM 0 SP Heavy Duty Sidewall Belt Drive Propeller Fan Ventilator with open Drip-proof Motor and Drive Assembly CFM at Static Pressure 115/1/60* /460/3/60 0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 STOCK NO. STOCK NO. 1/ L2E24MH1S N/A 1/ L2E24PH1S L2E24PH3S 1/ L2E24QH1S L2E24QH3S 3/ L2E24RH1S L2E24RH3S L2E24SH1S L2E24SH3S 1 1/ L2E24TH1S L2E24TH3S 1/ L2E30PH1S N/A 1/ L2E30QH1S L2E30QH3S 3/ L2E30RH1S L2E30RH3S L2E30SH1S L2E30SH3S 1 1/ L2E30TH1S L2E30TH3S 1/ L2E36QH1S L2E36QH3S 3/ L2E36RH1S L2E36RH3S L2E36SH1S L2E36SH3S 1 1/ L2E36TH1S L2E36TH3S L2E36VH1S L2E36VH3S N/A L2E36WH3S 1/ L2E42PH1S L2E42PH3S 1/ L2E42QH1S L2E42QH3S 3/ L2E42RH1S L2E42RH3S L2E42SH1S L2E42SH3S 1 1/ L2E42TH1S L2E42TH3S L2E42VH1S L2E42VH3S N/A L2E42WH3S N/A L2E42XH3S 1/ L2E48QH1S L2E48QH3S 3/ L2E48RH1S L2E48RH3S L2E48SH1S L2E48SH3S 1 1/ L2E48TH1S L2E48TH3S L2E48VH1S L2E48VH3S N/A L2E48WH3S N/A L2E48XH3S Performance ratings include the effects of appurtenances (accessories). Power ratings (BHP) do not include transmission losses. Performance certified is for installation type A-free inlet, free outlet. The sound ratings shown are loudness values in fan 5 (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Installation Type A: free inlet hemispherical sone levels. *Tri-voltage ( ) is standard on 3/4 through 1 1/2 Hp Single phase motors. Tri-voltage is available for the 1/2 Hp motors. Inquire for price and delivery. PROPELLER WALL/DUCT FANS 43

44 R CM BELT DRIVEN UTILITY VENT SET SWSI ARRANGEMENT #10 CLASS 1 CONSTRUCTION UTILITY VENT SET CENTRIFUGAL FANS Application S&P s Model CM is available in a full range of sizes (10 through 36) provides airflow performance from 500 CFM to over 21,000 CFM with static pressure up to 5 in. w.g. This single inlet backward inclined utility fan provides substantial benefits for pressure flow, low power consumption and low noise level, ideal for commercial and industrial applications. Typical applications include either supply or exhaust service for ducted systems in schools, theaters, gymnasiums, manufacturing plants, hotels, office buildings, restaurant hoods, and many other general ventilation applications. The turbine performance, minimizes unnecessary energy losses resulting in a system with high efficiency. Its design, manufacture and testing guarantee a long operating life with low maintenance. Also having great versatility in arrangements, and available positions with a complete series of mounting accessories for installation and proper operation of equipment for each application. The mechanical design and construction determines the maximum operating speed and power. The performance ranges shown on the following pages comply with the Class I operating limits as defined in AMCA standard 99. Type: UTILITY VENT SET Type of Wheel: Backward Inclined Rotation: CW and CCW Sizes: 10, 12, 14, 16, 18, 20, 22, 24, 27, 30, 36 Construction Housing & Drive Frame Structure The unit is solidly built, housing joints are welded intervals, this provides greater strength, accuracy on the boards and makes a robust unit, which is an added value. Wheel Backward inclined centrifugal wheel is constructed of steel blades protected with a polyester powder coat finish. All wheels are statically and dynamically balanced to ISO 1940 and AMCA 204-G2.5 standards. Paint The unit is subjected to a coil coating process, where the steel is treated chemically to ensure the adherence of the polyester paint. Subsequently, powder coating is bonded to the parts through an electrostatic process, where after baking the piece takes on its highest characteristics corrosion resistance, with great adhesion properties and impact resistance. Shafts and Bearings Turned, ground and polished allow steel shafts sized so the first critical speed is at least 30% over the maximum operating speed. Standard bearings are heavy-duty, self-aligning pillow block ball bearings with minimum L10 life in excess of 100,000 hours at maximum cataloged operating conditions. Motors Heavy-duty ball bearing motors are factory mounted on an adjustable base for ease of service and belt maintenance. Standard motor enclosures are Open Drip Proof (ODP). Drives V-belt drives are selected for a minimum safety factor of 150% of the driven horsepower. Cast iron motor pulleys are adjustable for final system balancing and are factory set to the required RPM range. Dual groove v-belt drives are standard for motors 5 HP thru 10 HP. Temperature Standard operating temperature range for culus 705 units is -20 F to 200 F. For fans with culus 762 construction the range is -20 F to 400 F. culus 762 Fan Installation Model CM is available with the 762 grease listing from UL. The fan will operate with continuous airstream temperatures of 400 F. Per NFPA 96, the fan discharge must be at least 40 inches above the roof line and the duct must be of all welded construction with a minimum distance of 18 inches above the roof line. Stock units are either CM, culus705 listed (non-grease) or CM- RHUL, culus762 listed (restaurant exhaust). CM - culus705 units include inlet/l-flange, weather cover, mounting rails, access door, threaded drain fitting and culus705 label. CM units have clockwise rotation and top horizontal configuration (CW-TH). CM-RHUL - culus762 units include inlet/l-flange, weather cover, threaded drain fitting, access door, mounting rails and culus762 label. CM-RHUL units have clockwise rotation and upblast configuration (CW-UB). AMCA SEAL SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. STANDARD 705 STANDARD

45 Discharge Positions culus 705 Clockwise Top Horizontal CW-TH E H B culus 762 Clockwise Upblast CW-UB L I A D C M G F J K K J N Dimensions Model A B C D E F G H I J K /8 7-1/8 9-7/8 23-7/8 17-1/4 1/2 16-7/8 25-3/8 15-1/ / /4 12-3/8 29-1/8 21-3/8 1/2 19-5/8 28-3/ / /4 22-3/4 1/2 19-5/8 30-3/4 17-7/ / /4 15-3/4 36-3/4 25-1/4 1/2 21-7/8 31-5/ / /2 12-1/8 17-3/4 40-7/8 28-1/2 1/2 24-3/ / / /4 13-5/8 19-3/4 44-7/8 31-1/4 1/2 27-1/2 38-3/8 21-5/ / /4 15-1/ /8 35 1/2 29-7/8 40-1/8 21-5/ / / /4 55-1/2 39-1/8 1/2 33-1/4 41-7/8 21-5/ / /2 18-7/ /8 44 1/2 35-1/ / / / / /4 1/2 39-3/8 53-3/4 28-3/ /4 23-3/8 35-1/2 82-1/2 55-1/4 1/ /8 32-1/ /8 Model L M N /4 21-5/ / / /8 29-1/ /2 34-3/8 32-3/ /4 37-1/2 36-1/ / / /8 45-7/8 44-5/ /2 55-5/8 50-5/ /4 62-3/8 57-1/ /4 70-1/2 64-3/8 Physical data Model Wheel Dia. (in) Outlet Area (sq. ft.) Avg. Weight Shaft Dia. Max RPM Max HP UTILITY VENT SET CENTRIFUGAL FANS 45

46 Options and Accessories Model CM U-Flange Inlet Outlet Flange Inlet Guard Outlet Guard Shaft Seal Stock # Stock # Stock # Stock # Stock # UTILITY VENT SET CENTRIFUGAL FANS Model CM Heavy-Duty Gravity Discharge Shutter Grease Trough Vibration Pads RIS SPRING Stock # Stock # Stock # Stock # BVS BVS BVS BVS BVS BVS BVS BVS BVS BVS BVS Ship Schedules: 10 Day Shipment 46

47 R CM Belt Driven Utility Vent Set SWSI Arrangement #10 Class 1 Construction HP Stock Number RPM Max CFM at Static Pressure (Inches w.g.) BHP 1/2 3/ /4 1 1/ / /4 CM10ML S /4 CM10MH S /3 CM10PH S /2 CM10QH S /4 CM10RH S /4 CM12MH S /3 CM12PH S /2 CM12QH S /4 CM12RH S CM12SH S CM12TH S 1/ CM12VH S Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. UTILITY VENT SET CENTRIFUGAL FANS C RU L U S LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. Ship Schedules: 10 Day Shipment 47

48 R UTILITY VENT SET CENTRIFUGAL FANS CM HP Stock Number RPM Max BHP 1/4 CM14MH S 1/3 CM14PH S 1/2 CM14QH S 3/4 CM14RH S 1 CM14SH S 1 1/2 CM14TH S 2 CM14VH S 3 CM14WH S 1/4 CM16MH S 1/3 CM16PH S 1/2 CM16QH S 3/4 CM16RH S 1 CM16SH S 1 1/2 CM16TH S 2 CM16VH S 3 CM16WH S Belt Driven Vent Set SWSI Arrangement #10 Class 1 Construction CFM at Static Pressure (Inches w.g.) 1/2 3/ /4 1 1/ / C RU L U S LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses.

49 R CM 18 Belt Driven Vent Set SWSI Arrangement #10 Class 1 Construction HP Stock Number RPM Max CFM at Static Pressure (Inches w.g.) BHP 1/2 3/ /4 1 1/ / /4 CM18MH S /3 CM18PH S 1/2 CM18QH S 3/4 CM18RH S 1 CM18SH S 1 1/2 CM18TH S 2 CM18VH S 3 CM18WH S 5 CM18XH S Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. C RU L U S How to order: LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 Model Number Motor HP SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. RPM Phase UL Stock Example: CM24 P H 1 U S Ship Schedules: CM24 P=1/3 L=Low 1 or 3 U=cULus705 S=Stock Q=1/2 M=Medium R=cULus762 R=3/4 H=High S=1 T=1 1/2 V=2 W=3 Indicates Customer Provided Information X=5 Y=7 1/2 10 Day Shipment Z=10 UTILITY VENT SET CENTRIFUGAL FANS 49

50 R UTILITY VENT SET CENTRIFUGAL FANS 20 CM Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. C RU L U S LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 Belt Driven Utility Vent Set SWSI Arrangement #10 Class 1 Construction HP Stock Number RPM Max CFM at Static Pressure (Inches w.g.) BHP 1/2 3/ /4 1 1/ / /3 CM20PH S /2 CM20QH S /4 CM20RH S CM20SH S /2 CM20TH S CM20VH S CM20WH S CM20XH S SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. Ship Schedules: 10 Day Shipment How to order: Model Number Motor HP RPM Phase UL Stock Example: CM24 P H 1 U S CM24 P=1/3 L=Low 1 or 3 U=cULus705 S=Stock Q=1/2 M=Medium R=cULus762 R=3/4 H=High S=1 T=1 1/2 V=2 W=3 Indicates Customer Provided Information X=5 Y=7 1/2 Z=10 50

51 R 22 CM Belt Driven Utility Vent Set SWSI Arrangement #10 Class 1 Construction HP Stock Number RPM Max CFM at Static Pressure (Inches w.g.) BHP 1/2 3/ /4 1 1/ / /3 CM22PH S /2 CM22QH S /4 CM22RH S CM22SH S /2 CM22TH S CM22VH S CM22WH S CM22XH S /2 CM22YH S UTILITY VENT SET CENTRIFUGAL FANS Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. C RU L U S LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. Ship Schedules: 10 Day Shipment 51

52 R UTILITY VENT SET CENTRIFUGAL FANS 24 CM Belt Driven Vent Set SWSI Arrangement #10 Class 1 Construction HP Stock Number RPM Max CFM at Static Pressure (Inches w.g.) BHP 1/2 3/ /4 1 1/ / /2 CM24QH S /4 CM24RH S CM24SH S /2 CM24TH S CM24VH S CM24WH S CM24XH S /2 CM24YH S CM24ZH S Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. C RU L U S LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 How to order: Model Number Motor HP SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. RPM Phase UL Stock Example: CM24 P H 1 U S Ship Schedules: 10 Day Shipment CM24 P=1/3 L=Low 1 or 3 U=cULus705 S=Stock Q=1/2 M=Medium R=cULus762 R=3/4 H=High S=1 T=1 1/2 V=2 W=3 Indicates Customer Provided Information X=5 Y=7 1/2 Z=10 52

53 R 27 CM HP Stock Number RPM Max BHP 1/2 CM27QH S 3/4 CM27RH S 1 CM27SH S 1 1/2 CM27TH S 2 CM27VH S 3 CM27WH S 5 CM27XH S 7 1/2 CM27YH S 10 CM27ZH S Belt Driven Vent Set SWSI Arrangement #10 Class 1 Construction CFM at Static Pressure (Inches w.g.) 1/2 3/ /4 1 1/ / Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. UTILITY VENT SET CENTRIFUGAL FANS C RU L U S LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. Ship Schedules: 10 Day Shipment 53

54 R UTILITY VENT SET CENTRIFUGAL FANS 30 CM Belt Driven Vent Set SWSI Arrangement #10 Class 1 Construction HP Stock Number RPM Max CFM at Static Pressure (Inches w.g.) BHP 1/2 3/ /4 1 1/ / /4 CM30RH S CM30SH S 1 1/2 CM30TH S 2 CM30VH S 3 CM30WH S 5 CM30XH S 7 1/2 CM30YH S 10 CM30ZH S Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. C RU L U S LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 How to order: Model Number Motor HP SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. RPM Phase UL Stock Example: CM24 P H 1 U S Ship Schedules: 10 Day Shipment CM24 P=1/3 L=Low 1 or 3 U=cULus705 S=Stock Q=1/2 M=Medium R=cULus762 R=3/4 H=High S=1 T=1 1/2 V=2 W=3 Indicates Customer Provided Information X=5 Y=7 1/2 Z=10 54

55 R 36 Performance certified is for installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. C CM RU L U S LISTED POWER ROOF VENTILATOR STANDARD 705 STANDARD 762 How to order: Model Number Belt Driven Vent Set SWSI Arrangement #10 Class 1 Construction HP Stock Number RPM Max CFM at Static Pressure (Inches w.g.) BHP 1/2 3/ /4 1 1/ / CM36SH S /2 CM36TH S CM36VH S CM36WH S CM36XH S /2 CM36YH S CM36ZH S Motor HP SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM 10). The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. RPM Phase UL Stock Example: CM24 P H 1 U S Ship Schedules: CM24 P=1/3 L=Low 1 or 3 U=cULus705 S=Stock Q=1/2 M=Medium R=cULus762 R=3/4 H=High S=1 T=1 1/2 V=2 W=3 Indicates Customer Provided Information X=5 Y=7 1/2 Z=10 10 Day Shipment UTILITY VENT SET CENTRIFUGAL FANS 55

56 R Sound Characteristics CM 10 Sound Performance Sones / LwA (Inches w.g.) RPM / / / / / / / / / / / / CM 12 CM / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 91.8 UTILITY VENT SET CENTRIFUGAL FANS CM 16 CM 18 CM 20 CM 22 CM 24 CM 27 CM / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CM / / / / / / / / / / / / / / / / / The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. Soler & Palau USA, certifies that the Models CM shown herein are licensed to bear the AMCA Seal (except CM SOUND 10). The ratings shown are based on test and procedures and performed in accordance with AMCA Publication 211 and PERFORMANCE MOVEMENT AMCA Publication 311 and comply with the requirement AND CONTROL ASSOCIATION of the AMCA Certified Ratings Program. INTERNATIONAL, INC.

57 RCXII/RCXII-SF GRAVITY RELIEF/INTAKE VENTILATOR APPLICATION Relief and intake ventilators are used to exhaust (relief) or supply (intake) air from or to an enclosed area without the need for a power operated fan. They rely on a difference in static pressure inside and outside the area to create an air flow through the ventilator from the area of higher pressure to the area of lower pressure. If the enclosed area is under a negative pressure, air will flow into the enclosed area (intake). If the enclosed area has a positive pressure, air will flow from it to the outside (relief). These units can also operate as gravity ventilators, allowing air to flow from an enclosed area using the Stack Effect. The amount of air flow will depend on the temperature difference inside and outside the area and the height difference between the ventilator and the outside air intake to the area. DIMENSIONAL DATA C RCXII (sizes 6-20) 2 D A B RCXII-SF = SELF FLASHING RCXII (sizes 24-36) C RCXII-SF D A B RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF (sizes 6-20) CONSTRUCTION - RCXII Low contour spun aluminum hood for attractive appearance. All heavy-gauge aluminum construction. Weather resistant design for long life and maintenance free operation. Galvanized bird screen is standard. One piece curb with spun inlet for maximum efficiency. Shipped completely assembled for ease in installation. CONSTRUCTION - RCXII-SF Low contour spun aluminum hood for attractive appearance. All heavy-gauge aluminum construction. Weather resistant design for long life and maintenance free operation. Galvanized bird screen is standard. Shipped completely assembled for ease in installation. Size A B (RCXII) B (RCXII-SF) C D Size Neck Area sq. ft. A B C D E /4 12-1/2 35-1/2 24-5/ /4 17-3/8 35-1/ /4 17-3/8 42-1/2 30-3/ /4 17-3/8 42-1/ /4 17-3/8 42-1/ GRAVITY VENTILATORS ACCESSORIES RCXII 12 HIGH ROOF CURB 115V MOTORIZED DAMPER AUTOMATIC GRAVITY DAMPER OD STOCK NO. OD STOCK NO. OD STOCK NO / M / M / M / M / M Dampers and motor kits ship separate - for field assembly. CAUTION: Motors are not suitable for explosive or flammable environments Ship Schedules: Next Day Shipment From Stock 10 Day Shipment ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. OD IS OUTSIDE DIMENSION OF SQUARE CURB AND DAMPER. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 57

58 Models RCXII (sizes 6-20) and Models RCXII-SF RCXII Gravity Relief Ventilator THROAT AREA CFM Static Pressure STOCK NO. FT RCXII STOCK NO. RCXII-SF RCXII06S RCXII06SFS RCXII08S RCXII08SFS RCXII10S RCXII10SFS RCXII12S RCXII12SFS RCXII14S RCXII14SFS RCXII16S RCXII16SFS RCXII18S RCXII18SFS RCXII20S RCXII20SFS RCXII Gravity Intake Ventilator THROAT AREA CFM Static Pressure STOCK NO. FT RCXII STOCK NO. RCXII-SF RCXII06S RCXII06SFS RCXII08S RCXII08SFS RCXII10S RCXII10SFS RCXII12S RCXII12SFS GRAVITY VENTILATORS RCXII14S RCXII14SFS RCXII16S RCXII16SFS RCXII18S RCXII18SFS RCXII20S RCXII20SFS Insect Screens - Add.10 to area shown in table. Damper - Add.10 to area shown in table. Model RCXII (sizes 24-36) Gravity Relief RCXII Ventilator THROAT AREA CFM Static Pressure STOCK NO. FT RCXII RCXII24S RCXII26S RCXII30S RCXII33S RCXII36S RCXII Gravity Intake Ventilator THROAT AREA CFM Static Pressure STOCK NO. FT RCXII RCXII24S RCXII26S RCXII30S RCXII33S RCXII36S Shaded selections are over recommended 650 FPM. Pick next larger size or use optional weather screen. Insect Screens - Add.10 to area shown in table. Damper - Add.10 to area shown in table. 58

59 V Bathroom Fans by RenewAire S&P s V-Series Bathroom Fan by RenewAire (an S&P company) is the best choice for exhaust-only ventilation. The V-Series improves indoor air quality and increase s your homes durability by quickly exhausting contaminants and excess moisture that can cause health issues, mold growth and structural damage. Performance The most energy efficient line of ceiling mounted ventilation fans available in North America. Aerodynamically engineered to move air with lowest power consumption and sound levels. Motors operate with the lowest heat build up for long life even when run continuously - 5 year warranty. Low air leakage dampers minimize uncontrolled infiltration. The lowest carbon footprint of leading residential ventilation brands. Construction Robust steel housing and duct collar Heat-sink motor unit Internal electrical wiring box Attractive, sturdy grille Impedance and thermal fuse electrical protection UL List for installation in tub/shower enclosures when connected to a GFCI protected branch circuit. Radiation Damper The V-Series Radiation Dampers are designed to meet local codes that require fans installed in fire rated ceilings to be protected by dampers which are insulated against both heat and flames. Model CFM Static Pressure (in W.G.) Energy Efficiency (CFM/Watts)* Watts Power (V/ Hz) Sones Amps V50 50/31 0.1/ /60 < V80 80/60 0.1/ /60 < V /93 0.1/ / V / / /60 < * Energy Star qualified data based on tested air flow and power consumption. Model Duct Dia. These are UL Classified radiation dampers rated at 1, 2 or 3 hours of fire resistance. Grille Size (Sq.) Cabinet Size W H D Hanging Bar Unit Wgt./Ship Wgt. (lbs) Radiation Damper (Loose) V x /8 9-7/8 8-1/16 7.7/10.4 VRD4 V x /8 9-7/8 8-1/16 7.7/10.4 VRD4 V x /8 9-7/8 8-1/16 7.7/10.4 VRD4 V /8 x 13-5/8 12-1/ /16 9-9/ /16.2 VRD6 V Control Stock No. Control Description Grille V-Series Fan Radiation Damper CEILING/CABINET FANS VSWITCH Line Voltage Fan Control Specifically designed for use with the V-Series fans May be used to comply with ASHRAE 62.2 ventilation rates for residential applications. 59

60 R FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as restrooms, conference rooms, offices, storage areas, restaurants, retail stores, schools, and similar buildings...anywhere quiet, high-capacity ventilation is needed. The forward curved centrifugal wheel with its high static pressure capability makes these ventilators suitable for either ducted or nonducted applications. They include removable blower assemblies and plug-in permanently lubricated motors for ease of servicing and cleaning. SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models FF/FFC shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. FF VOLTS Hz AMPS CFM SONES STOCK NO. 50E FF50E CEILING/CABINET FANS FF FF 60HZ/ WATTS 1/8 Ceiling Ventilator CFM / Sones at Static Pressure 0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1 Ventilator with Motor, Grille & Backdraft Damper Average Ship Wt. Lbs 120/1/60 STOCK NO / FF / FF / FF / FF / FF / FF / FF / FF / FF / FF / FF / FF Performance ratings include the effects of inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type B: free inlet fan sone levels. Performance certified is for installation Type B: Free inlet, Ducted outlet. Ship Schedules: Next Day Shipment From Stock 60 DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.

61 R FF/FFC cont d CONSTRUCTION Housing Rugged, 20 gauge galvanized steel. Duct connector. 1/2 acoustic insulation inside (except FF50, FF80 & FFC s). Integral automatic backdraft damper. Easy inline conversion available (FF100-FF1500). Mounting brackets for easy installation and adaptability to numerous mounting requirements. Factory shipped in horizontal discharge position easily converted to vertical discharge. FFC inline units have a removable panel which allows for easy motor access without disturbing duct work. Blower Low RPM for quiet operation, speed controllable. Resilient anti-vibration mounts (FF50 & FF80 rigid mount). Balanced, polymeric, centrifugal blower wheel for quiet, efficient performance. (Metal wheel on FFC2000 & FFC3500). Permanently lubricated, thermally protected motor. Plug in motor designed for continuous operation. Grille Conceals interior. Low profile styling, blends with any decor. White polymeric (FF50 - FF300). Metal finished with white enamel (FF400 - FF1500). ACCESSORIES Complete selection available, see pages SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Soler & Palau USA, certifies that the Models FF/FFC shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the AMCA Certified Ratings Program. FFC FFC 60HZ/ WATTS 1/8 Inline/Cabinet Ventilators CFM / Sones at Static Pressure 0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1 Ventilator with Motor and Duct Connectors Average Ship Wt. Lbs. 120/1/60 STOCK NO / FFC / FFC / FFC / FFC / FFC / FFC / FFC / FFC / FFC / FFC Performance ratings include the effects of backdraft damper in the airstream. Speed (RPM) shown is nominal. Performances based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 (1.5m) in a hemispherical free field calculated per AMCA Std Values shown are for installation Type D. Ducted inlet, Ducted outlet. Ratings do not include the effect of duct end correction. Performance ratings include the effects of 18 feet of round inlet duct and, if needed, a rectangular to round duct transition in the airstream. Performance certified is for Installation Type D; Ducted inlet, Ducted outlet. CEILING/CABINET FANS FFC FFC 60HZ/ WATTS 1/8 Inline/Cabinet Ventilators Ventilator with Motor and Duct Connectors CFM / Sones at Static Pressure Average Ship Wt. 120/1/60 0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1 Lbs. STOCK NO / FFC Performance ratings do not include the effects of appurtenances in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 (1.5m) in a hemispherical free field calculated per AMCA Std Values shown are for installation Type D: Ducted inlet, Ducted outlet. Ratings do not include the effect of duct end correction. Performance certified is for Installation Type D; Ducted inlet, Ducted outlet. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 61

62 DIMENSIONAL DATA - CEILING VENTILATOR FF50 & FF50E Inline/Cabinet Ventilator CEILING/CABINET FANS 62

63 ACCESSORIES 961L In-Line Adaptor Kit Galvanized steel Fits FF100 & FF150 For 6 round duct intake 982L In-Line Adaptor Kit Galvanized steel Fits FF400, FF500 & FF /2 x 18 1/2 duct intake 981L In-Line Adaptor Kit Galvanized steel Fits FF200, FF250 & FF300 For 8 round duct intake 983 In-Line Adaptor Kit Galvanized steel Fits FF900 & FF x 12 round duct intake Model 441 Wall Cap Gravity dampers Collar with birdscreen for attaching 10 round duct Steel construction with aluminum louvers Model 613 Wall Cap High Capacity Built-in backdraft damper & birdscreen Aluminum natural finish For 12 round duct Model 641 Wall Cap Aluminum natural finish Built-in backdraft damper & birdscreen For 6 round duct Model 642 Wall Cap Aluminum natural finish Built-in backdraft damper & birdscreen For 3 or 4 round duct (4 to 3 transition included) Model 643 Wall Cap Aluminum natural finish Built-in backdraft damper For 8 round duct CEILING/CABINET FANS Model 437 Roof Cap High capacity design - up to 1200 CFM Built-in birdscreen Steel, black electrically - bonded epoxy finish Model 636 Roof Cap Black electrically - bonded epoxy finish Built-in backdraft damper & birdscreen For 3 or 4 round duct Model 636AL - Aluminum Model 634 Roof Cap Black electrically - bonded epoxy finish Built-in backdraft damper & birdscreen For 3 1/4 x 10 or up to 8 round duct Model Aluminum 63

64 ACCESSORIES Speed Control Adjust speed from 100 to 50% 3 amp, 5 amp & 10 amp - 120V 6 amp - 240V 20 Model RCXIISF08 Flat Roof Cap For flat roof installation Spun Aluminum - natural finish Built-in birdscreen For up to 8 round duct Model RCXII08 Curb Mount Roof Cap For curb mount installation Use 14-3/4 x 14-3/4 x 12 high curb Spun Aluminum - natural finish Built-in birdscreen For up to 8 round duct Model RCXIISF12 Flat Roof Cap For flat roof installation Spun Aluminum - natural finish Built-in birdscreen For up to 12 round duct Model RCXII12 612CM Curb Curb Mount Roof Roof Cap Cap For For curb curb mount installation Use Aluminum 22-1/4 - x natural 22-1/4 finish x 12 high curb. Spun Built-in Aluminum birdscreen - natural finish Built-in For up birdscreen to 12 round duct For up to 12 round duct Model MG 1 Metal Grille Kit White enamel painted steel Mounting screws included Fits FF100, FF150, FF200, FF250 & FF300 CEILING/CABINET FANS Models RD1, RD2 & RD3 Radiation Dampers UL rated for use in 1, 2 or 3 hour rated floor-ceiling, roof-ceiling design Galvanized steel frame High temperature, non-asbestos, reinforced fiber thermal fabric 212 F fusible link Stainless steel negator-type closure spring RD1 (12 1/4 x 12 1/4 ) fits FF100 - FF300 RD2 (211/2 x 18 ) fits FF400 - FF700 RD3 (22 x 18 ) fits FF900 - FF1500 Models 423 & T81212 Duct Transitions Galvanized steel D Allows for quick transition to easy-to-obtain-and-install round ducting 423 ( 4 1/2 x 18 to 10 round) for use with FF400 thru FF700 T81212 ( 8 x 12 to 12 round) for use with C FF900 and FF Model RCXII - 18 and 20 units Size A B C D A B 64

65 FF/FFC Optional Accessory Compatibility Chart Ceiling & Inline/Cabinet Ventilators STOCK NO. CEILING MOUNT FF IN-LINE/CABINET FFC VARIABLE SPEED CONTROLS FF50 FF50E FF80 FF100 FF150 FF200 FF250 FF300 FF400 FF500 FF700 FF900 FF1500 FFC100 FFC150 FFC200 FFC250 FFC300 FFC400 FFC500 FFC700 FFC900 FFC1500 FFC (5 AMP 120V) X X X X X X (10AMP 120V) X X X X X X X X X X X X ROOF CAPS 437 X X X RCXIISF08, RCXII08 X X X X X RCXIISF12, RCXII12 X X X X X X X X 634 X X X X 636 X RCXII18 X RCXII20 X ROOF CURBS FOR RCXII08 & RCXII X X X X X X X X X X X X X WALL CAPS 441 X X X 613 X X X X 641 X X 642 X 643 X X IN-LINE ADAPTERS 961L X 981L X 982L X X 983L X X UL RADIATION DAMPERS RD1 X X RD2 X X RD3 X X METAL Grille KIT G102 X MG1 X X DUCT TRANSITIONS 423 X X X T81212 X X X X DAMPER KITS D100 X VIBRATION DAMPENING HANGERS (4) v102 X X X X X X X X X X X HEAVY DUTY v104 X X X X X X X X X X X X CEILING/CABINET FANS Ship Schedules: Next Day Shipment From Stock 10 Day Shipment 65

66 S IF AND HP INDUSTRIAL CEILING FANS APPLICATION All models are ideal for factories, warehouses, retail stores & garages The WR water resistant and high performance is ideal agricultural, greenhouse and high moisture application Heat de-stratification. Insect control Air curtain for shipping doors Employee, machine and compressor cooling By removing hot air from the ceiling you can increase light & ballast life IF - Series FEATURE AND BENEFITS Sealed bearings no maintenance required Extra 24 lead wires coming out of fan for easy adapting to longer downrods 24 stainless steel safety cable Low energy consumption maintenance free motors 24 standard downrod length Painted aluminum blades WR series has water resistant motors Quiet operation UL approved HP - Series CEILING/CABINET FANS (STOCK NO.) SIZE FLOW MAX RPM VELOCITY 5 FROM FAN CFM WATTS H/L AMPS DOWNROD LENGTH IF48C 48 Downdraft / WEIGHT IF56C 56 Downdraft / IFR56 56 Forward/Reverse / HPWR56 56 Downdraft / HPWR60 60 Forward/Reverse / Ship Schedules: Next Day Shipment From Stock 66 ALL DIMENSIONS IN INCHES, WEIGHTS IN POUNDS. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.

67 ROOF VENTILATOR ACCESSORIES PREFABRICATED ROOF CURB Factory built curbs reduce installation time and assure proper fit of ventilator and curb. STANDARD CANTED ROOF CURB FEATURES Continuously welded 18 gauge galvanized steel with integral base plate. 1 1/2 x 1 1/2 wood nailer. 1 semi-rigid insulation. Fully mitered 3 cant. Damper mounting flange (damper tray). A = Curb OD, see specific ventilators for recommended size. B = Curb height, 12 standard C = Nailer width, 1 1/2 standard. STANDARD CANTED ROOF CURB RESTAURANT ROOF CURB STANDARD FEATURES Constructed of 18 ga. galv. steel with continuous welded seams and integral base plate for water tightness and extra strength. Wide base flashing to insure adequate bond to roofing surface for water tight seal to roof. Insulation not furnished when curb is equipped with special ventilation slots. Top of curb covered with 1/4 polystyrene gasket for weather seal and to reduce metal to metal conducted noise. Minimum curb height is 18 to comply with NFPA Bulletin 96 (K + 7 ) 4 VENTED RESTAURANT ROOF CURB STANDARD DUTY - BOX FRAME BACKDRAFT DAMPER For exhaust ventilator models DB, RED, LPD, TXD, TXB and ARE. For supply fan - refer to the flanged frame damper on the following page. Maximum face velocity FPM. 19 gauge galvanized steel frame. 26 gauge aluminum blades. Stainless steel pivots. Felt seal between blades. Adjustable spring counter balance. Max 250 F ambient temp (130 F for motor). ACCESSORIES Notes: (1) Units are undersized 1/4 to fit in square ducts or inside the roof curb. (2) Do not mount fan less than 1/3 diameter of the fan from the damper. (3) Dampers shipped in individual cartons. (4) Motor kits ship loose for field installation. A = Damper OD, see specific ventilator for specific size. DO NOT USE A DAMPER IN GREASE REMOVAL APPLICATIONS OR WITH A UL-762 LISTED EXHAUST FAN FOR KITCHEN VENTILATION CAUTION: Motor kits are not suitable for use in explosive or flammable areas or airflows. DUE TO CONTINUING RESEARCH, SOLER & PALAU RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. 67

Quickship Program. Quick Delivery Wide Product Selection Competitive Price

Quickship Program. Quick Delivery Wide Product Selection Competitive Price Quickship Program Centrifugal Roof & Wall Exhausters Centrifugal Filtered Supply Propeller Roof Ventilators Propeller Wall Fans Recovery Ventilators Utility Sets Ceiling/Cabinet Fans Gravity Ventilators

More information

Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast

Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall Roof Downblast Models LPD & RED LPD Applications/Construction LPD Performance/Dimensions RED Applications/Construction RED Performance/Dimensions

More information

Centrifugal Filtered Supply Fans

Centrifugal Filtered Supply Fans Centrifugal Filtered Supply Fans Model KSF Application/Construction Options/Accessories Construction Features Performance/Dimensions NFPA96 Installation/Common TXB Series Restaurant Exhauster Additional

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER MODEL CWD MODEL FEATURES Exhaust air up to 3,360 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

sidewall propeller fans L 1.07 models lc, l2 & l3 january 2007 belt drive - exhaust & supply three levels of construction

sidewall propeller fans L 1.07 models lc, l2 & l3 january 2007 belt drive - exhaust & supply three levels of construction R SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Jenco, Div. of Soler & Palau Ventilation Group, certifies that the models shown herein are licensed to bear the AMCA Seal. The

More information

EcoWatt Products. Advancing Ventilation

EcoWatt Products. Advancing Ventilation EcoWatt Products Advancing Ventilation EcoWatt-0817 August 2017 What is EcoWatt At S&P we strive to engineer and manufacture the most efficient products in the market. In order to categorize our most energy

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview

More information

Advancing Ventilation

Advancing Ventilation Centrifugal oof Sidewall LPD CWD STXD STXDe SDBD SDBDe SDB STXB Direct Drive Belt Drive Centrifugal oof Sidewall Fans Advancing Ventilation centrifugal-roof--sidewall-0219 February 2019 MODEL LPD LOW POFILE

More information

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS R MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as

More information

Downblast Centrifugal Fans with ECM

Downblast Centrifugal Fans with ECM Downblast Centrifugal Fans with ECM Model ered Featuring Electronically Commutated Motors GC_eRED_0512 May 2012 1 Motor Up to 90% efficient, electronically commutated motor (ECM) DOWNBLAST CENTRIFUGAL

More information

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as restrooms,

More information

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER Model Features Exhaust air up to 6,817 CFM in high static pressure applications up to 3 Belt drives permit easy performance adjustments when needed Nonoverloading backward inclined wheel for efficiency

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS S CSF & LSF Model CSF Hooded Design FEATURES Supply air to over 13,000 CFM in static pressure capabilities to 2 w.g. Heavy-galvanized construction Belt drives permit easy performance adjustments when needed

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

CONSTRUCTION FEATURES AND OPTIONS

CONSTRUCTION FEATURES AND OPTIONS MODEL SQD & esqd MODEL FEATURES Exhaust air up to 2,8 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except

More information

Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements.

Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements. CWBA Sizes 12 to 20 711 to 5709 CFM Static Pressure to 2 AMCA Licensed Ratings for Sound and Air CWDA Sizes 06 to 20 133 to 4942 CFM Static Pressure to 1 AMCA Licensed Ratings for Sound and Air Safety

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC MODEL FF FEATURES Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation Speed

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Propeller Hooded Roof Fans

Propeller Hooded Roof Fans Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

Bulletin REXJR05 CENTREX REX JR. Model: REXJR Direct Drive Centrifugal Inline Fans

Bulletin REXJR05 CENTREX REX JR. Model: REXJR Direct Drive Centrifugal Inline Fans Bulletin REXJR05 CENTREX REX JR. Model: REXJR Direct Drive Centrifugal Inline Fans Centrifugal Inline Fans Introduction CERTIFIED RATINGS Centrifugal Inline Fans PennBarry certifies that the Centrex REX

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside

More information

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the

More information

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS BULLETIN 0 January 007 SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS TYPE ACX / ACXD TYPE ATD / ATDR / ATDW / ATDWR TYPE ATB / ATBR / AWX / AWXR Model ACX Model ATB Model ACXD Model ATDR Model AWX Centrifugal

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION

More information

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page SRSH Tamper Proof Downblast Centrifugal Exhaust Ventilators Page Introduction....................................... 2 SRSH-D Specifications and Dimension Data............. 3 SRSH-B Specifications and

More information

Inline Fans [ 14 ] * UL is optional and must be specified.

Inline Fans [ 14 ] * UL is optional and must be specified. XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC

More information

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type. January 2008 FADE0108 Fantech, Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof

More information

Commercial and Residential Product Lines

Commercial and Residential Product Lines Commercial and Residential Product Lines Centrifugal Roof & Wall Exhausters Centrifugal Filtered Supply Propeller Roof Ventilators Propeller Wall Fans Recovery Ventilators Utility Sets Ceiling/Cabinet

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

LINEA Low Discharge Roof Exhausters

LINEA Low Discharge Roof Exhausters LINEA Low Discharge Roof Exhausters TECHNICAL SPECIFICATIONS BULLETIN LF18 PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION

More information

MIN/MAX PERFORMANCE IN INCHES WG

MIN/MAX PERFORMANCE IN INCHES WG Fans Roof Exhaust Direct Drive - G Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels

More information

Type VA Vanax Fans. Models VA, VAD, & VAB

Type VA Vanax Fans. Models VA, VAD, & VAB Type VA Vanax Fans Models VA, VAD, & VAB Type VA Direct Drive Model VA Sizes 6 through 10 207 to 1,811 CFM Static Pressure to 1-1/2 Type VAB Belt Drive Model VAB Sizes 12 through 48 1,004 to 47,176 CFM

More information

Belt Drive Centrifugal Roof Exhauster Model PV

Belt Drive Centrifugal Roof Exhauster Model PV Belt Drive Centrifugal Roof Exhauster Model PV Model PV belt drive fans are centrifugal power roof ventilators designed for exhausting clean air. Capacities up to 40,608 CFM and up to 2 inch static pressure.

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2.

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2. BDU Belt Drive - Centrifugal Up-Blast Fans W HT F Grease Drain B R RO Features & Benefits Complete range of motors available to meet specific application needs Heavy duty construction, durable and weather

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

Low Silhouette Power Roof Ventilator Propeller

Low Silhouette Power Roof Ventilator Propeller LOW SILHOUETTE Models LT, LG and LF Power Roof Ventilator Propeller Contemporary Styling Carnes line of low silhouette power roof ventilators are ideal for installations requiring high performance and

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

K SERIES SIDEWALL PROPELLER FANS

K SERIES SIDEWALL PROPELLER FANS K SERIES S Models LWBK/LMBK and LRBK/LNBK K SERIES S The Carnes Sidewall Propeller Fan series Models LW/LM and LR/LN have been designed for quiet and efficient air flow performance with the lowest possible

More information

FarmTek Stock Numbers

FarmTek Stock Numbers FarmTek Stock Numbers 109292, 109286 = 109293, 109287 = 109294, 109288 = 109295, 109289 = 109290 = 109297, 109291 = 109285, 109300 = FADE 8 FADE 10 FADE 12 FADE 14 FADE 16 FADE 18 FADE 20-6 FADE 20-4 FADE

More information

PRODUCT FEATURES. BEARING LIFE All bearings are designed for L50 life of 200,000 hours.

PRODUCT FEATURES. BEARING LIFE All bearings are designed for L50 life of 200,000 hours. PRODUCT FEATURES These fans must be installed in a manner which insures that the exhausted air and the surrounding environment are always free of flammable gases, vapors, or liquids, combustible dusts

More information

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available

More information

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 52,000 CFM in static pressure applications up to 3/4 w.g. Motor and drives are located outside of the exhaust

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 405 April 2009 UPBLAST ROOF, WALL, & KITCHEN EXHAUSTERS TYPE DCRU / DCRUR / DCRW / DCRWR TYPE BCRU / BCRUR / BCRW / BCRWR TYPE BCRUSH (Smoke & Heat) Upblast Roof, Wall,

More information

Commercial Fans & Dampers

Commercial Fans & Dampers Commercial Fans & Dampers CUD DIRECT DRIVE UPBLAST FANS FEATURES & BENEFITS Suitable for roof or wall mount Backward inclined, non-overloading wheels Spun aluminum housing for weather-resistant durability

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS UPBLAST PROPELLER FANS Model LUBK SECTION 16 MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS Application Model LUBK is a high capacity roof mounted exhauster rated from 3,560 to 42,000 CFM. It

More information

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive

More information

MODEL FF50 CEILING FAN

MODEL FF50 CEILING FAN MODEL FF50 CEILING FAN SPECIFICATION SHEET Simple installation dependability make this odor moisture removing fan a real value. Matte white polymeric blends well with any decor Torsion spring grill mounting

More information

Bulletin DXA08 DOMEX AXIAL. Models: DAS, DAE Roof Ventilators Direct Drive MOVING YOUR WAY

Bulletin DXA08 DOMEX AXIAL. Models: DAS, DAE Roof Ventilators Direct Drive MOVING YOUR WAY Bulletin DXA08 TM DOMEX AXIAL Models: DAS, DAE Roof Ventilators Direct Drive MOVING YOUR WAY Dome Aial Supply & Ehaust Fans Table of Contents Dome Aial Series Model: DAS Static pressure up to 0.5 in. wg.

More information

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 model vp - belt drive utility set Application VENT-PAK fan wheels are the versatile, quiet, energy efficiency backward inclined

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with

More information

Square Inline Fans with Multi-Directional Discharge

Square Inline Fans with Multi-Directional Discharge SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension

More information

Propeller Upblast Roof Fans

Propeller Upblast Roof Fans Propeller Upblast Roof Fans Models RBU, RBUMO, RDU and RGU Direct Drive, Belt Drive and Gravity April 2010 Propeller Upblast Roof Fans Greenheck upblast propeller fans are designed to discharge contaminants

More information

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS K Series Direct Drive K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS SPECIFICATIONS Fans shall be direct drive propeller type with integral motorside OSHA style guard. Propeller construction shall be of

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

Fumex. Upblast Roof Exhauster Technical Specifications BULLETIN FX17

Fumex. Upblast Roof Exhauster Technical Specifications BULLETIN FX17 Upblast Roof Exhauster Technical Specifications BULLETIN FX17 TABLE OF CONTENTS Introduction 3 Direct Drive Dimensional & Performance Data 4 Enhanced Direct Drive Dimensional & Performance Data 8 Belt

More information

MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MODL TX either ducted or nonducted applications. Its roof or sidewall mounting options permit location near the area to be and buildings. Typical applications include restaurant hoods and similar your

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

Wholesale Ventilation Products

Wholesale Ventilation Products Wholesale Ventilation Products... better AIRFLOW by ESIGN! RM IRECT RIVE AXIAL EXHAUST FANS RM Axial Exhaust Fans are suitable for roof or wall mounting in commercial ventilation applications. They are

More information

Air Movement SOURCE BOOK ACME AIR MOVING SOLUTIONS. Est

Air Movement SOURCE BOOK ACME AIR MOVING SOLUTIONS. Est Air Movement SOURCE BOOK ACME AIR MOVING SOLUTIONS www.acmefan.com Est. 1938 Quality and Service that will Blow you Away! Industry Leadership Founded in 1938, Acme Engineering and Manufacturing Corporation

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

CEILING & INLINE/CABINET VENTILATORS

CEILING & INLINE/CABINET VENTILATORS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 MARCH 2018 CEILING & INLINE VENTILATORS OVERVIEW T I TL T-Series

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information