ADVANCED INSTRUMENTATION RESERCH FACILITY USER CHARGES w.e.f Equipment JNU Academic & Research Institutions / IITs/IISERs/Univ.
|
|
- Britton Horton
- 6 years ago
- Views:
Transcription
1 Transimission Electron Microscope (TEM) Bio. Sample Prep. Rs Bio. Sample Prep. Rs Bio. Sample Prep Negative Staining Rs. 600 Negative Staining Rs Negative Staining TEM Viewing Rs. 600 TEM Viewing Rs TEM Viewing Rs TEM Viewing & EDX Rs. 850 TEM Viewing & EDX Rs TEM Viewing & EDX Rs TEM Viewing & EDX Mapping Rs TEM Viewing & EDX Mapping Rs TEM Viewing & EDX Mapping Rs Scanning Electron Coating Rs. 250 Coating Rs. 500 Coating Rs. 650 Microscope (SEM) Bio. Sample Prep. Rs. 400 Bio. Sample Prep. Rs Bio. Sample Prep. Rs High Vacuum Mode : SEM Viewing Rs. 250 SEM Viewing & EDX Rs. 700 SEM Viewing & EDX Rs SEM Viewing & EDX Rs. 500 SEM Viewing & EDX Rs SEM Viewing & EDX Rs Multipoint Rs. 800 Multipoint Multipoint Rs SEM Viewing &EDX Mapping Rs. 850 SEM Viewing &EDX Mapping SEM Viewing &EDX Mapping Rs Low Vacuum Mode : Viewing Rs. 500 Viewing Rs Viewing Rs Page 1
2 Confocal Microscope FRET and FRAP Rs. 400 per hour FRET and FRAP Rs per hour FRET and FRAP Rs per hour Time Resolved Rs. 200 per hour 1200 Fluescence per day Spectrometer (TRFS) Rs. 300 per hour 2700 per day Rs per hour Rs per day Liquid Nitrogen (LN2) Rs. 30 per litre Rs. 60 per litre Rs. 100 per litre FTIR- Raman FTIR Rs. 200 FTIR Rs. 500 FTIR Rs Raman Rs. 250 Raman Rs. 600 Raman Rs IR - Microscope Rs. 300 IR- Microscope Rs IR- Microscope X-Ray Diffraction System f Powder- Thin Films with low temp. XRD at Variable temprature Remarks: Rs. 250 per sample Rs. 800 per sample Rs per sample Rs. 500 and per scan at Rs per scan at different + per scan at different different tempratures tempratures Rs. 300 tempratures Rs. 500 Rs Sample should be crushed and brought in powder fm 2. Maximum of one requisition fm per user will be accepted in one single day. Subsequent requisition fm of same user will be accepted f booking and analysis only after all other user booked f the dayhave finished their analysis. 3. The maximum time f analysis of one sample is one hour. After every one hour, the same sample would be treated as new sample and charged accdingly. Page 2
3 EDXRF ADVANCED INSTRUMENTATION RESERCH FACILITY A) A) i) Pellet Fm: Rs. 500 per sample Rs per sample ii) Aerosol Filters: ii) Aerosol Filters: Rs. 500 per sample Rs. 1000/- per sample B) In Helium Mode: B) In Helium Mode: i) Loose Fm: i) Loose Fm: Rs. 600 per sample Rs per sample ii) Liquid Samples: ii)liquid Samples: Rs. 600 per sample Rs per sample In Vacuum Mode: 10 Maj oxides Element 10 Maj oxides Element with with Rs. 500 per Rs sample Charges f Trace Level per Charges f Trace Level element: per element: Rs. 30 Rs. 15 (Min. Charges (Minimum Charges Rs.1000 per Rs.500 per In Helium Mode: Charges In Helium Mode: Charges per element with standard: Rs. 40 (Minimum Charges Rs. 200 per per element with standard: Rs. 20 (Minimum Charges Rs. 100 per Samples * Charges f a sample Samples * Charges f Elements A) ii) Aerosol Filters: Rs per sample B) In Helium Mode: i) Loose Fm: ii) Liquid Samples: 10 Maj oxides Element with Charges f Trace Level per element: Rs. 45 (Min. Charges /- per In Helium Mode: Charges per element with standard: Rs. 60 (Minimum Charges Rs. 300 per Samples * Charges f Elements WDXRF A) Rs. 400 per sample 10 Maj oxides Elements with Rs. 400 Charges f Trace Level per element: Rs. 15 (Minimum Charges Rs. 400 per Samples * Charges f Elements A) Rs per sample 10 Maj oxides Element with Rs Charges f Trace Level per element: Rs. 30 (Minimum Charges Rs per Samples * Charges f Elements A) 10 Maj oxides Element with Charges f Trace Level per element: Rs. 45 (Minimum Charges per Samples * Charges f Elements Page 3
4 Protein Crystallization Lab. F XRD Rs. 320 per sample Consumable: Rs. 220 Plate Rs. 160 Rs. 500 per sample Consumables: Rs. 400 Plate Rs. 300 Rs per sample Consumables: Rs Plate Rs. 500 X-Ray Diffractometer (XRD) f Macromolecules & Proteins Rs. 700 per samples Rs per sample Gas Chromatograph Mass Spectrometer (GCMS) GC Rs. 250 GCMS Rs. 500 GC Rs. 500 GCMS Rs GC Rs GCMS Rs Multivapour Rs. 50 Rs. 100 Rs MHz Nuclear Magnetic Resonance (NMR) Spectrometer with solid state attachment (CPMAS) a) 1H NMR Rs. 200 a) 1H NMR Rs. 400 b) 13C and other nuclei Rs. b) 13C and other nuclei Rs c) 2D experiment Rs c) 2D expmnt Rs. 500 e) Solid-state experiment: e) Solid-state experiment: i) 1H NMR i) 1H NMR Rs. 500 ii) 13C NMR Other Nuclei: Rs. ii) 13C NMR Other Nuclei: 3600 Rs. 600 f) Variable Temperature: f) Variable Temperature: i) High Temp. Rs. 300 i) High Temp. Rs.150 ii) Low Temp. Rs. not available f ii) Low Temp. Rs. 250 external users Charges to be added with g) Additional Deuterated Solvent experiments a/b/c/d/e Charges: D2O/CDCl3, DMSO-d6 g) Additional Deuterated Rs. 150 per sample Solvent Charges: D2O/CDCl3, DMSO-d6 Rs. 100 a) 1H NMR Rs. 800 b) 13C and other nuclei Rs C) 2D experiment Rs e) Solid-state experiment: i) 1H NMR Rs ii) 13C NMR Other Nuclei: Rs f) Variable Temperature: i) High Temp. Rs. 500 ii) Low Temp. Rs. not available f external users g) Additional Deuterated Solvent Charges: D2O/CDCl3, DMSO-d6 Rs. 450 per sample Page 4
5 Surface Plasmon Resonance (SPR) Spectrometer Rs. 600 per day SPR bare gold discs: Rs consumables: Rs. 500 per experiement Vacuum filter assembly Rs per day SPR bare gold discs: Rs consumables: Rs per experiement Vacuum filter assembly Rs per day SPR bare gold discs: Rs consumables: Rs per experiement Vacuum filter assembly Galvanostat- Potentiostat f electrochemical measurements Rs.100 f each sample/analysis Consumables: Rs.250 Rs. 100 f each sample/analysis Consumables:Rs.500 Rs.500/- f each sample/analysis Consumables: Rs Mass Spectrometry MALDI based analysis 1. Intact Mass / MW MALDI based analysis 1. Intact Mass / MW Determination: Rs. 250 Determination: Rs Peptide Mass 2.Peptide Mass Fingerprinting Fingerprinting (PMF):Rs.1000 (PMF):Rs MS/MS Protein Id:Rs MS/MS Protein Id:Rs LC-Maldi (Protein 4.LC-Maldi (Protein Id/PTMs):Rs.5000 Id/PTMs):Rs iTRAQanalysis:Rs-50,000 5.iTRAQanalysis:Rs-12,000 6.MS/Ms analysis per 6.MS/MS analysis Precursion):Rs.500 (perprecursion): Rs.250 LC-ESI-MS/MS LC-ESI-MS/MS based 1.InactMass/MW analysis determination:rs InactMass/MW 2.UPLC-MS/MS determ:rs.400 analysis(qualitative):rs UPLC-MS/MS 3.UPLCanalysis(Qualitative): Rs.600 MS/MSanalysis(perPrecursion): 3. UPLC-MS/MS analysis Rs.5000 (Qualitative): Rs MS/MS analysis(per MS/MS analysis per Rs. 300 Precursion):Rs RP/RP 2D-nano LC- 5.RP/RP 2D-nano LC- MS/MS:Rs.2000 MS/MS:Rs.4000 OffGel Fractionat OffGel Fractionat Rs.1000 per sample Rs.2000 per sample Bio Analyzer Bio Analyzer Rs.1500 per chip (12 Rs.3000 per chip (12 MALDI based analysis 1. Intact Mass / MW Determination: Rs Peptide Mass Fingerprinting (PMF):Rs MS/MS Protein Id:Rs LC-Maldi (Protein Id/PTMs):Rs iTRAQanalysis:Rs2.5 lac 6.MS/Msanalysis(per Precursion):Rs.1500 LC-ESI-MS/MS 1.InactMass/MW determination:rs UPLC- MS/MSanalysis(Qualitative):Rs UPLC- MS/MSanalysis(perPrecursion): Rs MS/MS analysis(per Precursion):Rs RP/RP 2D-nano LC- MS/MS:Rs OffGel Fractionat Rs.3000 per sample Bio Analyzer Rs.4500 per chip (12 Page 5
6 Femtosecond Laser Facility (Fluescence Upconversion) Rs per day Rs. 250 per hour Rs per day Rs. 375 per hour Rs per day Circular Dichroism Spectrometer Rs. 200 per hour Rs. 700 per hour Rs per hour Stop Flow Rs. 100 per sample Rs. 500 per sample Rs per sample Cell Ster and Flow Cytometer Rs. 600 per hour / per 10 samples f flow cytometer (incl. Sheath fluid charges) Rs per hour / per 10 samples f flow cytometer (incl. Sheath fluid charges) Rs per hour / per 10 samples f flow cytometer (incl. Sheath fluid charges) Quartz Crystal Microbalance Rs. 100 f each sample Quartz crystal Ti/Au: Rs Consumables: Rs. 250 per day Rs. 200 f each sample Quartz crystal Ti/Au: Rs Consumables: Rs. 500 per day Rs. 100 f each sample Quartz crystal Ti/Au: Rs Consumables: Rs per day Physical Property Measurement System (PPMS) Rs per day Rs. 175 per hour Rs per day Rs. 350 per hour Rs per day Live Cell Confocal Microscope Rs. 750 per hour TIRF beyond 6 hrs. Rs, 600 Rs. 450 per hour Bio Station Rs. 450 per hour Rs per hour TIRF per hour Bio Station per hour Rs per hour TIRF Rs per hour Bio Station Rs per hour Page 6
7 Electron Paramagnetic Resonance Spectroscopy with low tempurature measurement setup Rs. 200 per sample 350 per hour Rs. 600 per sample Rs per sample EPR at different tempratures consumables: [Model: Bruker EMX MicroX] Rs. 600 per sample per scan at different temprature Rs. 200 Rs. 100 per sample per scan at different tempratures Rs. 500 Rs 200 per sample Rs per sample per scan at different temprature Rs Rs. 500 per sample Operating Frequency 9.7 GHz Temprature: upto 100K Combined Confocal Raman- AFM Microscope Rs. 250 per sample Raman Single Spectra Rs. 200 per sample Raman Imaging Rs. 300 per sample Rs. 500 per sample Raman Single Spectra Rs. 400 per sample Raman Imaging Rs. 600 per sample Rs per sample Raman Single Spectra Rs. 800 per sample Raman Imaging Rs per sample Field Emssion High Vacuum Mode Scanning Electron Rs. 300 per sample Microscope (FESEM) Low Vacuum Mode with Focussed Ion Rs. 600 per sample Beam (FIB) *Charges is only f viewing High Vacuum Mode Rs. 700 per sample Low Vacuum Mode Rs per sample *Charges is only f viewing High Vacuum Mode Low Vacuum Mode Rs per sample *Charges is only f viewing FCS Rs. 150 per hour Rs per day Rs. 250 per hour Rs per day Rs per day Simulation Labaty (Schrodinger Software) Rs. 50 per hour Rs. 100 per hour Rs. 200 per hour Page 7
URB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C)
O NH O NH O. GENERAL INFORMATION IUPAC Name: 3'-carbamoylbiphenyl-3-yl cyclohexylcarbamate CAS#: 56-08-6 Synonyms: Source: Appearance: UV max (nm): KDS-03 DEA Reference Material Collection White powder
More informationCHAPTER 2 LITERATURE REVIEW AND SCOPE OF THE PRESENT STUDY
57 CHAPTER 2 LITERATURE REVIEW AND SCOPE OF THE PRESENT STUDY 2.1 LITERATURE REVIEW Biodiesel have been processed from various plant derived oil sources including both Edible and Non-Edible oils. But,
More informationCAMN Industrial Liaison Program (ILP) Equipment and Labor Rates 5/1/2018
Equipment and Labor s Categories: for ILP Members for s for ILP Members Basis for s Electron Microscopy SEM Hitachi 4300 FEGSEM hour 50 120 178 236 134 204 262 320 FEI SCIOS FIB/SEM hour 50 120 178.00
More informationFacilities Costs 2019 refinement, it is expected that they will be co-authors on any publication arising from the experiment.
Instrument type Sydney Analytical University of Sydney External University Users & Publicly Funded Research Organisations 1 Vibrational Spectroscopy $ 50 / hour $ 130 / hour instruments Portable instruments:
More informationSupplementary Figure 1 Vertical FF peptide microrod arrays. a,b, Top view of the microrod arrays from the positive-ef growth (a) and negative-ef
Supplementary Figure 1 Vertical FF peptide microrod arrays. a,b, Top view of the microrod arrays from the positive-ef growth (a) and negative-ef growth (b). Insets: enlarged view of microrods. The scale
More informationSupplementary Figure 1: Supplementary Figure 2: XRD patterns of charged and discharged graphite
Supplementary Figure 1: UV/Vis absorption spectra of dilution series of pure potassium in benzonitrile. For the quantitative reaction of K + PhCN K + + PhCN.- the radical anion concentration can be determined
More informationConsumables and Supplies Required for Repair
Consumables and Supplies Required for Repair Specification When your system needs repair, you want complete coverage, without having to generate a separate purchase order for the consumables or supplies
More informationCHAPTER 3 EXPERIMENTAL METHODS AND ANALYSIS
37 CHAPTER 3 EXPERIMENTAL METHODS AND ANALYSIS 3.1 MATERIALS H-Mordenite (MOR) (Si /Al ratio= 19), - zeolite ( ) (Al /Si ratio= 25), silica gels with two different mesh sizes, 100-120 (S 1 ) and 60-120
More informationSPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)
SPECIFICATION Bench top triple quadrupole Mass performance Chromatography (GC-MS/MS) 1. Scope These specifications describe the requirements for a bench top triple quadrupole mass spectrometry system coupled
More informationTechnical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)
Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the pyrolysis-gas chromatograph-mass spectrometer
More informationOur Solutions for Automotive.
Our Solutions for Automotive www.horiba.com info.sci@horiba.com Solutions for Automotive Your Lab Partner Analytical examples of all vehicle parts We support new material developments required for next-generation
More informationIFPAC 2003 Dr. Berthold Andres
IFPAC 2003 Dr. Berthold Andres ABB Automation Products Germany Microelectromechanical Systems for Process Analytics Copyright 2002 ABB. All rights reserved. - Process Analyzer and Instrumentation Water
More informationGC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585
GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585 Application Note Fuels Author James D. McCurry, Ph.D. Agilent Technologies, Inc. 850 Centerville
More informationBright prospects Solvents for spectroscopy Uvasol
Bright prospects Solvents for spectroscopy Uvasol EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Simply the best UV/VIS and infrared spectroscopy are reliable and accurate methods
More informationNew Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared
New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared John Coates Coates Consulting Process Spectroscopy IFPAC-2014 Thursday PM VIII New Approaches in Spectroscopic Measurements:
More informationBattery Fingerprint Technologies
Battery Fingerprint Technologies Battery diagnostics for manufacturers and users to improve capacity, reliability, and safety Emilia Silletta AEC 2018 - March 27 th, 2018 Samsung Galaxy Note 7 Current
More informationElvaX Sulfur in Oil analyzer
ElvaX Sulfur in Oil analyzer Introduction ElvaX Sulfur in Oil was designed especially for analysis of petrochemicals for sulfur content in wide concentration range from ppm to 5%. Many international standards
More informationA Continuous Flow Microwave Reactor for Conducting. High Temperature and High Pressure Chemical Reactions
A Continuous Flow Microwave Reactor for Conducting High Temperature and High Pressure Chemical Reactions Supporting Information Jennifer M. Sauks, 1,2 Debasis Mallik, 2 Yuri Lawryshyn, 1 Timothy P. Bender,
More informationXylan Reinforcement on Poplar Cellulose Nanowhiskers films
Xylan Reinforcement on Poplar Cellulose Nanowhiskers films Qining Sun Prof. Art Ragauskas Group School of Chemistry and Biochemistry Institute of Paper Science and Technology 1 Hemicellulose Lignin Cellulose
More informationASTM D2007M/ASTM D2549M In-house method/astm D6560/D3279
ID Test Standard Amount Required Price for Cost Recovery Projects (Can $) 1 2 3 4 5 Sulfur compounds distribution by boiling point (GC-SCD) Sulfur compound speciation by GC-SCD Nitrogen compounds distribution
More information[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS
MS Identification of Trace level Impurities from a Non-MS Compatible Mobile Phase Using ACQUITY UPLC System with 2D Technology by Heart-cutting and Online Sample Concentration Bronsky Gopinadh, Dilshad
More informationSupporting Information for jo051589t Synthesis of 2-Nitro and 2,2 -Dinitro-biphenyls by means of the Suzuki Cross-Coupling Reaction.
upporting Information for jo051589t ynthesis of 2-Nitro and 2,2 -Dinitro-biphenyls by means of the uzuki Cross-Coupling Reaction. Raquel Rodríguez González, Lucia Liguori, Alberto Martinez Carrillo, and
More informationAnalysis and Identification of Contaminants in Diesel Fuel Filtration and Storage Systems
Paper No. IFC10-020 Analysis and Identification of Contaminants in Diesel Fuel Filtration and Storage Systems Steven R. Westbrook Southwest Research Institute James Doyle Philip Johnson Donaldson Company
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SOUTHWEST RESEARCH INSTITUTE Office of Automotive Engineering Fuels and Lubricants Research Division 6220 Culebra Road, P.O. Drawer 28510 San Antonio, TX 78228-0510
More informationThe Streaker Air-Particulate Sampler Instruction Manual
The Streaker Air-Particulate Sampler Instruction Manual PIXE International Corporation P 0 Box 2744 / Tallahassee, FL 32316 / Voicemail-FAX +1 404 551 5458 email: info@pixeintl.com www: http://pixeintl.com
More informationSPECTRO XRF Report. SPECTRO iq II
No. XRF-40 by SPECTRO 2007 SPECTRO iq II Summary The SPECTRO iq II simultaneous XRF spectrometer provides a fast, precise, accurate and economic solution for the analysis of the S content in Ethanol and
More informationI-Lab Glovebox Systems QUALITY YOU CAN COUNT ON. Inert s line of I-Lab Glovebox Systems are designed as an economical solution for inert research appl
I-Lab Glovebox Systems QUALITY YOU CAN COUNT ON. Inert s line of I-Lab Glovebox Systems are designed as an economical solution for inert research applications. As with all our Gloveboxes, I-Lab Gloveboxes
More informationKF-loaded mesoporous Mg-Fe bi-metal oxides: high performance transesterification catalysts for biodiesel production
Electronic Supplementary Information (ESI) KF-loaded mesoporous Mg-Fe bi-metal oxides: high performance transesterification catalysts for biodiesel production Guiju Tao, a Zile Hua,* a Zhe Gao, b Yan Zhu,
More informationDAYTIME AND NIGHTTIME AGING OF LOGWOOD COMBUSTION AEROSOLS
DAYTIME AND NIGHTTIME AGING OF LOGWOOD COMBUSTION AEROSOLS Ari Leskinen Finnish Meteorological Institute Atmospheric Research Centre of Eastern Finland 20th ETH-Conference on Combustion Generated Nanoparticles,
More informationSundar Mayavan Lead Acid Battery Group CSIR- Central Electrochemical Research Institute Karaikudi, INDIA. 22/9/ th Asian Battery Conference 1
Influence of Carbon Nanotubes, Glycine, Boron-Carbon- Nitride and Molybdenum disulfide as Negative-Plate Additives on the Performance of Lead Acid Batteries Sundar Mayavan Lead Acid Battery Group CSIR-
More informationSurvey of Commercial Small Lithium Polymer Batteries
Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6110--07-9073 Survey of Commercial Small Lithium Polymer Batteries Arnold M. Stux Karen Swider-Lyons Chemical Dynamics and Diagnostics Branch
More informationMESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis
MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis ASTM 7220 Pooled Limit of Quantitation (PLOQ) of 3 ppm S in a wide variety
More informationVarian, Inc. Vacuum Technologies. Turbo-V Pumps. Turbo-V Pumps Features and Benefits 2-3. Turbo-V SEM Features and Benefits 4-5
Varian, Inc. Vacuum Technologies Turbo-V Turbo-V Features and Benefits 2-3 Turbo-V SEM Features and Benefits 4-5 Typical Applications 6-11 Pump Models 12-31 Pump Controllers 32-38 Accessories 40-41 Technical
More informationThermal Battery Development Reduced Product Variability Through Six Sigma and Materials Finger-Printing
Power Sources Center 50 th Annual NDIA Fuze Conference Norfolk, VA 9-11 May 2006 Thermal Battery Development Reduced Product Variability Through Six Sigma and Materials Finger-Printing Authors: Paul F.
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SOUTHWEST RESEARCH INSTITUTE Office of Automotive Engineering Fuels and Lubricants Research Division 6220 Culebra Road, P.O. Drawer 28510 San Antonio, TX 78228-0510
More informationCODE DESCRIPTION QUANTITY. ANNEX AGRI / 14 - IRRIGATION ANNEX AGRI / 14 A - Sustainable Ground Water Use for Irrigation Purposes and Animal Watering
ANNEX AGRI / 14 A - Sustainable Ground Water Use for Irrigation Purposes and Animal Watering 05-14-00001 Deep well vertical turbine pumping set complete 300 Pcs 05-14-00002A Truck with Loading Crane 12
More informationASTM D7039. Sulfur analysis plus a further 21 elements by MWDXRF. Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF
Spectrolab Science cat71120p Sulfur analysis plus a further 21 elements by MWDXRF Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF ASTM D7039 and other standards For
More informationDFS High Resolution GC/MS High Performance Magnetic Sector GC/MS
mass spectrometry DFS High Resolution GC/MS High Performance Magnetic Sector GC/MS The DFS High Resolution GC/MS is the highest performance magnetic sector mass spectrometer ever built for target compound
More informationMiscellaneous NMR parts and accessories
Miscellaneous NMR parts and accessories Quartz glass Inserts for Bruker Probes DC-402 DC-403 5 mm Quartz glass Insert for newer Probes (5.575 x 6.1 x 64 mm) 5 mm Quartz glass Insert for Dual-Flow Probes
More informationFlexible transparent displays based on core/shell upconversion nanophosphor-incorporated polymer waveguides
Supplementary Information Flexible transparent displays based on core/shell upconversion nanophosphor-incorporated polymer waveguides Bong Je Park, 1, A-Ra Hong, 2,3, Suntak Park, 1 Ki-Uk Kyung, 1 Kwangyeol
More informationAntek Gas Chromatography Products: A Guided Tour Through Industry
ANTEK GC Application Solutions Feature the Following Detectors: Antek Sulfur and Nitrogen Chemiluminescence, Flame Ionization, Thermal Conductivity, Nitrogen-Phosphorus, Atomic Emission, Halogen Specific,
More informationSupplementary Information
Supplementary Information Cu(II)-Catalyzed Domino Reaction of 2H-Azirines with Diazotetramic and Diazotetronic Acids. Synthesis of 2-Substituted 2H-1,2,3-Triazoles Nikolai V. Rostovskii, a Mikhail S. Novikov,
More informationCHAPTER 1 INTRODUCTION
1 CHAPTER 1 INTRODUCTION 1.1 GENERAL With a rapid increase in the demand of fossil fuel, decrease in the availability of crude oil supplies and greater environmental stringent norms on pollution has created
More informationProgress in UCSD Chamber Simulation Experiments
Progress in UCSD Chamber Simulation Experiments Farrokh Najmabadi Sophia Chen, Andres Gaeris, John Pulsifer HAPL Meeting December 5-6, 2002 Naval Research Lab, Washington, DC Electronic copy: http://aries.ucsd.edu/najmabadi/talks
More informationMESA-7220 Multi-Element Analyzer Using EDXRF Technology
THE MESA-7220 X-RAY FLUORESCENCE ANALYZER Measurement of Sulfur and Chlorine in Petroleum Products using Monochromatic, Polarized EDXRF Analysis The MESA-7220 now features an 8-tray turntable. Programmable
More informationnext TURBOMOLECULAR PUMPS
edwardsvacuum.com next TURBOMOLECULAR PUMPS THE PARTNER OF CHOICE Edwards is a world leader in the design, technology and manufacture of vacuum pumps with over 95 years history and more than 75 years manufacturing
More informationTURBOVAC ix Turbomolecular Pumps 90 l/s l/s
TURBOVAC ix Turbomolecular Pumps 90 l/s - 450 l/s 175.62.02 Discover new dimensions With TURBOVAC ix, highest functionality meets outstanding performance. Our ix turbomolecular pump range with integrated
More informationBILLING RATES - FY 17/18
Room 17 (Materials Testing Equipment) Use of 10 kip UTM Day $500.00 External Use of Torsion Machine Day $500.00 External Room 21 Lowry (soil mechanics lab) Use of Soil Mechanics Lab (room 21 Lowry ) Hour
More informationStudies on Capacity Fade of Spinel-Based Li-Ion Batteries
A54 0013-4651/2001/149 1 /A54/7/$7.00 The Electrochemical Society, Inc. Studies on Capacity Fade of Spinel-Based Li-Ion Batteries Ramadass Premanand, Anand Durairajan,* Bala Haran,** Ralph White,*** and
More informationSUPPORTING INFORMATION
Electronic Supplementary Material (ESI) for Green Chemistry. This journal is The Royal Society of Chemistry 2016 Dace Rasina, a Aurora Lombi, a Stefano Santoro, a Francesco Ferlin, a and Luigi Vaccaro*
More informationDetermination of Phenolic Antioxidant DBPC and DBP Levels in Electrical Insulating Oil
Determination of Phenolic Antioxidant DBPC and DBP Levels in Electrical Insulating Oil Agilent 5500, 4500, and Cary 630 FTIR Spectrometers Application Note Authors Dipak Mainali and Frank Higgins Agilent
More informationMASCOT Marco Polo Surface Scout. Progress Report on Lander Package Study for Marco Polo
MASCOT Marco Polo Surface Scout Progress Report on Lander Package Study for Marco Polo Lutz Richter 1, Lars Witte 1, Tra-Mi Ho 1, Stephan Ulamec 2, Jean-Pierre Bibring 3 1 DLR Bremen, 2 DLR Cologne, 3
More informationAcceptance and use of MOLECULAR REBAR
Acceptance and use of MOLECULAR REBAR in challenging new lead acid battery markets Mohamed Sharif, Venkat B Black Diamond Structures, Austin TX USA 1 Who We Are Black Diamond Structures is a developer,
More informationHeterogeneous Palladium-Catalysed Catellani Reaction in Biomass-Derived γ-valerolactone
Electronic Supplementary Material (ESI) for Green Chemistry. This journal is The Royal Society of Chemistry 2016 Heterogeneous Palladium-Catalysed Catellani Reaction in Biomass-Derived γ-valerolactone
More informationAGA Touch Up & Repair Videos. 35% inconsistency/ difference in appearance main factor
Poor quality touch-up & repair leads to eventual maintenance by the user Specifier Survey: 12% users, 30% non-users quoted aesthetics as primary reason to avoid HDG 35% inconsistency/ difference in appearance
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR Kanpur , Uttar Pradesh, India Centre for Lasers and Photonics
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Kanpur 208016, Uttar Pradesh, India Centre for Lasers and Photonics Enquiry no.: CELP/RV/EQP/MHR/2017/1 Enquiry date: 23/04/2018 Closing date: 17/05/2018 Sealed quotations
More informationTechnical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)
Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph-mass spectrometer (GC-MS). 2.0 Scope
More informationAppendix A.1 Calculations of Engine Exhaust Gas Composition...9
Foreword...xi Acknowledgments...xiii Introduction... xv Chapter 1 Engine Emissions...1 1.1 Characteristics of Engine Exhaust Gas...1 1.1.1 Major Components of Engine Exhaust Gas...1 1.1.2 Units Used for
More informationIncreased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel
Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W
More informationOptical Techniques in Gasoline Engine Performance and Emissions Development Injector Spray Visualisation
Injector Spray Visualisation Denis Gill, Wolfgang Krankenedl, DEC Ernst Winklhofer 20.03.15 Emissions Development Injector Spray Visualisation Contents Introduction Spray Box Direct Injection (GDI) Spray
More informationA Flex Fle ible, ible, Po Po t r a t ble Inst Ins rument rumen Plat Pla fo f rm r fo FT IR Analys Analy is
A Flexible, Portable Instrument Platform for FT IR Analysis Series Introduction StandardlaboratoryFT IRspectrometers have many desirable qualities, but are not generally considered portable. Dedicated,
More informationSupporting information
Supporting information Table S1. Tensor parameters and shift of metal ion from starting position for the 10 subsets (from a total of 100) resulting in the largest number of peak pairings, using 2D and
More informationIndium Tin Oxide (ITO) Coated Glass Slides
Indium Tin Oxide (ITO) Coated Glass Slides Techinstro sell ITO Coated Glass, excellent quality with the finest transparency at lowest price around the world you can compare it. Available in various sizes
More informationAntimony/Graphitic Carbon Composite Anode for High- Performance Sodium-Ion Batteries
Supporting Information Antimony/Graphitic Carbon Composite Anode for High- Performance Sodium-Ion Batteries Xin Zhao, Sean A. Vail, Yuhao Lu *, Jie Song, Wei Pan, David R. Evans, Jong-Jan Lee Sharp Laboratories
More informationDatasheet High Capacity battery pack for nano-satellites featuring four Li- Ion cells
NanoPower BP4 Datasheet High Capacity battery pack for nano-satellites featuring four Li- Ion cells 1 Table of Contents 1 TABLE OF CONTENTS... 2 2 SYSTEM OVERVIEW... 3 2.1 HIGHLIGHTED FEATURES... 3 2.2
More informationArticle: The Formation & Testing of Sludge in Bunker Fuels By Dr Sunil Kumar Laboratory Manager VPS Fujairah 15th January 2018
Article: The Formation & Testing of Sludge in Bunker Fuels By Dr Sunil Kumar Laboratory Manager VPS Fujairah 15th January 2018 Introduction Sludge formation in bunker fuel is the source of major operational
More informationThe Role of Diesel Soot in the Tribological Behavior of 150SN Base Oil
Lubrication Research China Petroleum Processing and Petrochemical Technology 2017, Vol. 19, No. 2, pp 89-95 June 30, 2017 The Role of Diesel Soot in the Tribological Behavior of 150SN Base Oil Su Peng
More informationGC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference
GC-101 Testing of Biodiesel Using Gas Chromatography by Bob Armantrout (Image Research Machines plc) Presented at: Local Biodiesel: A Biodiesel Coop Conference Strategies For Community-based Biodiesel
More informationCRYO FTIR.
FTIR Cryostats Cryostats for FTIR Experiments Cryo Industries Variable Temperature Continuous Flow Cryostas (Models RC-102 and RC-152) are an excellent choice for Fourier Transform Infra-Red (FTIR) spectroscopy
More informationWaters Xevo TQ-S IVD Mass Spectrometry System Operator s Overview and Maintenance Guide
Waters Xevo TQ-S IVD Mass Spectrometry System Operator s Overview and Maintenance Guide Revision A Copyright Waters Corporation 2010 All rights reserved Copyright notice 2010 WATERS CORPORATION. PRINTED
More informationSUPPORTING INFORMATION
Electronic Supplementary Material (ESI) for Organic & Biomolecular Chemistry. This journal is The Royal Society of Chemistry 2015 SUPPORTING INFORMATION Grignard-mediated reduction of 2,2,2-trichloro-1-arylethanones:
More informationVIII.5 Hydrogen Fuel Quality
VIII.5 Hydrogen Fuel Quality T. Rockward (Primary Contact), C. Quesada, K. Rau, E. Brosha, F. Garzon, and R. Mukundan P.O Box 1663 Los Alamos National Laboratory (LANL) Los Alamos, NM 87545 Phone: (55)
More informationWaters Xevo TQ-S Mass Spectrometry System Operator s Overview and Maintenance Guide
Waters Xevo TQ-S Mass Spectrometry System Operator s Overview and Maintenance Guide Revision A Copyright Waters Corporation 2010 All rights reserved Copyright notice 2010 WATERS CORPORATION. PRINTED IN
More informationTURBOVAC i Turbomolecular Pumps 90 l/s l/s
TURBOVAC i Turbomolecular Pumps 90 l/s - 450 l/s 175.61.02 A giant leap in vacuum performance! It has never been so easy to improve your processes until now. TURBOVAC 90-450 i will allow you to optimize
More informationCharacterization of particle emissions from a marine diesel engine: Influence of sampling temperature on particle number, size, and morphology
Characterization of particle emissions from a marine diesel engine: Influence of sampling temperature on particle number, size, and morphology Fuglsang, K. 1, Dierscherl, K. 2, Lykkegaard, M.K. 3, Markussen
More informationSynthesis of Biphenyl-Based Arsine Ligands by Suzuki-Miyaura Coupling and their Application to Pd-Catalyzed Arsination
Synthesis of Biphenyl-Based Arsine Ligands by Suzuki-Miyaura Coupling and their Application to Pd-Catalyzed Arsination Paula M. Uberman, Mario N. Lanteri, Sol C. Parajón Puenzo and Sandra E. Martín* INFIQC,
More informationBILLING RATES - FY 18/19
Room 21 Lowry (soil mechanics lab) Use of Soil Mechanics Lab (room 21 Lowry ) Atterberg plastic limit test (ASTM D4318) Atterberg liquid limit test (ASTM D4318) Sieve analysis with wash #200 sieve (ASTM
More informationVacuum Level. Fermi Level. W f W Bottom of conduction. (a) Vacuum Level. Fermi Level e - W W. X1= X2 (b) (c)
E Vacuum Level Fermi Level W f W 0 W Bottom of conduction (a) Met Vacuu Vacuum Level E Fermi Level e - W W W X1= X2 (b) Tunneling Phenomenon (c) Fig. 1.1 Energy diagrams of vacuum-metal boundary: (a) without
More informationC09. Turbomolecular Pumps l x s -1. vacuum
179.01.01 Excerpt from the Product Section Edition May 2005 Turbomolecular Pumps 35-3200 l x s -1 vacuum Turbomolecular Pumps Contents General General...............................................03 Applications...........................................12
More informationThe Effects of the Tribo-Conditions and Antiwear Additives on the Degradation of an Ester Oil and Analyses of Degradation Products
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1998 The Effects of the Tribo-Conditions and Antiwear Additives on the Degradation of an
More informationElectronic Supporting Information
Electronic Supporting Information Locked Chromophores as CD Probes for the Helical Conformation of Tetraamidic Macrocycles Carmine Coluccini, a Andrea Mazzanti, b and Dario Pasini*,a a) Department of Organic
More informationSupporting Information
Supporting Information Extremely Stable Polypyrrole Achieved via Molecular Ordering for Highly Flexible Supercapacitors Yan Huang, Minshen Zhu, Zengxia Pei, Yang Huang, Huiyuan Geng, and Chunyi Zhi *,,
More informationDUCOM HIGH FREQUENCY RECIPROCATING RIG
DUCOM HIGH FREQUENCY RECIPROCATING RIG Product information sheet Asia 477/A, 4 th Phase, Peenya industrial area,bangalore-560 058,India Phone: +91-80-4080-5555 Fax: +91-80-4080-5510 America 620, Johnson
More informationSupporting Information
Supporting Information Silver, Gold, Palladium, and Platinum N-heterocyclic Carbene Complexes Containing a Selenoether-Functionalized Imidazol-2-ylidene Moiety Karsten Klauke, Irina Gruber, Tim-Oliver
More informationBeyond the Hype. What does the journey to metal AM production really look like? Adam Rivard
Beyond the Hype What does the journey to metal AM production really look like? August 2016 Adam Rivard ARivard@LAIco.com 207-756-5544 Beyond the Hype: How to get there? The Best Machine Control Integrate
More informationWEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony. October 31,
WEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony October 31, 2012 1 WDXRF for Petrochemical Analysis: More Than a One-Trick Pony Arkady Buman Product Manager XRF North America Today
More informationLithium battery knowledge
Seminar on Safe Transport of Lithium Battery by Air Lithium battery knowledge 12 December 2008 At Cathay City s s Auditorium Battery Association of Japan(BAJ) 1 Seminar on Safe Transport of Lithium Battery
More informationIndex. Springer International Publishing Switzerland 2015 M. Tehranipoor et al., Counterfeit Integrated Circuits, DOI /
Index A AACF. See Areal autocorrelation function (AACF) Accelerated aging, 103, 159, 160, 165 167, 173, 189 Active metering, 176, 226, 251 Additive watermarking, 208, 213 215 Advanced detection, 133 153,
More informationI. Equivalent Circuit Models Lecture 3: Electrochemical Energy Storage
I. Equivalent Circuit Models Lecture 3: Electrochemical Energy Storage MIT Student In this lecture, we will learn some examples of electrochemical energy storage. A general idea of electrochemical energy
More informationAgilent Turbo-V Pumps
Agilent Turbo-V 2-3 TwisTorr Technology 4-5 TwisTorr Key Features 6-15 TwisTorr Pump Models 16-17 Turbo-V Features and Benefits 18-19 Turbo-V SEM Features and Benefits 20-23 Typical Applications 24-41
More informationAdvanced Technique for Si 1-x Ge x Characterization: Infrared Spectroscopic Ellipsometry
Advanced Technique for Si 1-x Ge x Characterization: Infrared Spectroscopic Ellipsometry Richard Sun Angstrom Sun Technologies Inc., Acton, MA Joint work with Darwin Enicks, I-Lih Teng, Janice Rubino ATMEL,
More informationAR2000ex Rheometer Standard Operating Procedures Revised: 5/1/2018
AR2000ex Rheometer Standard Operating Procedures Revised: 5/1/2018 Startup Procedure 1) Remove the black bearing lock by holding it place while turning the draw rod knob on the top of the instrument counterclockwise.
More information// ZSW Laboratory for Battery Technology (elab)
// ZSW Laboratory for Battery Technology (elab) Now that the elab has been extended with industrial manufacturing technology, we have all the areas of battery research housed uniquely under one roof with
More informationPractical Applications of Compact High-Resolution 60 MHz Permanent Magnet NMR Systems for Reaction Monitoring and Online Process Control
Practical Applications of Compact High-Resolution 60 MHz Permanent Magnet NMR Systems for Reaction Monitoring and Online Process Control Presented By John Edwards, Ph.D., LLC Danbury, Connecticut March
More informationItems for the Environment Laboratory of DASH Department
Items for the Environment Laboratory of DASH Department Annexure A Sl.No. Item Short Specifications 1 BOD incubator # Inner dimension W X D X H in cms: 45 x 45 x 45 Cm. # Capacity: 4 CFt # Display: Digital
More informationIntroduction During a time of foreign fuel dependency and high green house gas emissions, it is
University of Tennessee at Chattanooga MOLAR RATIO STUDY FOR THE REACTION OF FREE FATTY ACIDS WITH METHANOL TO FORM FATTY ACID METHYL ESTERS OR BIODIESEL FUEL by Trip Dacus ENCH 435 Course: Ench435 Section:
More informationSupplementary Information for A library-screening approach to developing a fluorescent sensing array for the detection of metal ions
Electronic Supplementary Material (ESI) for Analyst. This journal is The Royal Society of Chemistry 2016 Supplementary Information for A library-screening approach to developing a fluorescent sensing array
More informationFRAUNHOFER INSTITUTE FOR CHEMICAL TECHNOLOGY ICT REDOX-FLOW BATTERY
FRAUNHOFER INSTITUTE FOR CHEMICAL TECHNOLOGY ICT REDOX-FLOW BATTERY REDOX-FLOW BATTERY REDOX-FLOW BATTERY Redox-flow batteries are efficient and have a longer service life than conventional batteries.
More informationSPECIFICATION FOR APPROVAL
FEB 25, 2004 CERAMIC DIPLEX FILTER SPECIFICATION 1 OF 6 SPECIFICATION FOR APPROVAL ITEM: CERAMIC DIPLEX FILTER PART NUMBER: CFD-122715756 ISSUED CHECKED CHECKED CHECKED APPROVED FILTRONETICS Inc FEB 25,
More informationMonitor Chlorine in Crude at Sub-ppm Levels
better analysis counts Monitor Chlorine in Crude at Sub-ppm Levels Benchtop and Online Analysis Solutions Total Chlorine Analysis in Liquid Hydrocarbons Clora is a compact analyzer to measure total chlorine
More information