BRAKE MODULES and RESISTORS

Size: px
Start display at page:

Download "BRAKE MODULES and RESISTORS"

Transcription

1 BRAKE MODULES and RESISTORS Can be used for the N3, MA7200 PLUS, PA7300, and 7200GS product families. 230V 3-Phase BRAKING TRANSISTOR BRAKING RESISTOR AC DRIVE MODEL QTY LIST MODEL QTY RESISTANCE ENCLOSURE BRAKING DUTY LIST RATING NUMBER USED PRICE NUMBER USED OHMS WATTS TORQUE % CYCLE % PRICE 1 X - - DBR "L X 5"W X 5"D X - - DBR "L X 5"W X 5"D X - - DBR "L X 5"W X 5"D X - - DBR "L X 5"W X 5"D X - - DBR "L X 7"W X 5"D X - - DBR "L X 7"W X 5"D X - - DBR "L X 10"W X 5"D , X - - DBR "L X 13"W X 5"D , JUVPLV DBR "L X 10"W X 5"D , JUVPLV DBR "L X 10"W X 5"D , JUVPLV DBR "L X 13"W X 5"D , JUVPLV DBR "L X 13"W X 5"D , JUVPLV DBR "L X 10"W X 5"D , JUVPLV DBR "L X 10"W X 5"D , JUVPLV DBR "L X 10"W X 5"D ,450 X= Transistor built-in for all MA7200, PA7300, and N3 Drives at these ratings. For braking applications above 100 at 230V or above 200 at 460V, please consult the factory. NOTE: All brake resistor units include thermal overload switches or call

2 BRAKE MODULES and RESISTORS 460V 3-Phase BRAKING TRANSISTOR BRAKING RESISTOR AC DRIVE MODEL QTY LIST MODEL QTY RESISTANCE ENCLOSURE BRAKING DUTY LIST RATING NUMBER USED PRICE NUMBER USED OHMS WATTS TORQUE % CYCLE % PRICE 1 X - - DBR "L X 5"W X 5"D X - - DBR "L X 5"W X 5"D X - - DBR "L X 5"W X 5"D X - - DBR "L X 5"W X 5"D X - - DBR "L X 7"W X 5"D X - - DBR "L X 7"W X 5"D X - - DBR "L X 10"W X 5"D X - - DBR "L X 13"W X 5"D JNTBU DBR "L X 13"W X 5"D , JNTBU DBR "L X 13"W X 5"D , JNTBU DBR "L X 13"W X 5"D , JUVPHV DBR "L X 10"W X 10"D , JUVPHV DBR "L X 10"W X 10"D , JNTBU DBR "L X 13"W X 5"D , JUVPHV DBR "L X 10"W X 10"D , JNTBU DBR "L X 13"W X 5"D , JNTBU DBR "L X 13"W X 5"D , JUVPHV DBR "L X 10"W X 10"D ,475 X = Transistor Built-in on all MA7200, PA7300, and N3 Drives at these ratings. For braking applications above 100 at 230V or above 200 at 460V, please consult the factory. NOTE: All brake resistor units include thermal overload switches. or call

3 LINE REACTORS Low priced and easy to install, Line Reactors provide input transient protection from harmonic distortion. When applying a reactor between the drive output and the motor, please contact the Factory. 230V 3% IMPEDANCE, 230V (LBS.) Dimensions KDRULA25L 4.00 x 4.18 x KDRULA25LE x x KDRULA26L 4.00 x 4.18 x KDRULA26LE x x KDRULA27L 4.00 x 4.18 x KDRULA27LE x x KDRULA28L 4.00 x 4.18 x KDRULA28LE x x KDRULB22L 5.00 x 6.00 x KDRULB22LE x x KDRULB23L 5.00 x 6.00 x KDRULB23LE x x KDRULD25L 5.75 x 7.20 x KDRULD25LE x x KDRULD24L 5.75 x 7.20 x KDRULD24LE x x KDRULD26L 5.75 x 7.20 x KDRULD26LE x x KDRULC22L 5.75 x 7.20 x KDRULC22LE x x KDRULF24L 7.00 x 9.00 x KDRULF24LE x x , KDRULF25L 7.00 x 9.00 x KDRULF25LE x x , KDRULF26L 7.00 x 9.00 x KDRULF26LE x x , KDRULH22L 9.00 x x ,050 KDRULH22LE x x , KDRULI23L 9.00 x x ,072 KDRULI23LE x x , KDRULI24L 9.00 x x ,200 KDRULI24LE x x ,100 5% IMPEDANCE, 230V PART # KDRULA25H 4.00 x 4.18 x KDRULA25HE x x KDRULA27H 4.00 x 4.18 x KDRULA27HE x x KDRULA26H 4.00 x 4.18 x KDRULA26HE x x KDRULA28H 4.00 x 4.18 x KDRULA28HE x x KDRULB25H 5.00 x 6.00 x KDRULB25HE x x KDRULB26H 5.00 x 6.00 x KDRULB26HE x x KDRULD21H 5.75 x 7.20 x KDRULD21HE x x KDRULD22H 5.75 x 7.20 x KDRULD22HE x x KDRULC22H 5.75 x 7.20 x KDRULC22HE x x KDRULF28H 7.00 x 9.00 x KDRULF28HE x x , KDRULF25H 7.00 x 9.00 x KDRULF25HE x x , KDRULF26H 7.00 x 9.00 x KDRULF26HE x x , KDRULH24H 9.00 x x KDRULH24HE x x , KDRULH23H 9.00 x x ,075 KDRULH23HE x x , KDRULI22H 9.00 x x ,300 KDRULI22HE x x , KDRULI21H 9.00 x x ,590 KDRULI21HE x x ,550 (LBS.) or call

4 LINE REACTORS 460V 3% IMPEDANCE, 460V PART # KDRULA8L 4.00 x 4.18 x KDRULA8LE x x KDRULA1L 4.00 x 4.18 x KDRULA1LE x x KDRULA2L 4.00 x 4.18 x KDRULA2LE x x KDRULA3L 4.00 x 4.18 x KDRULA3LE x x KDRULA4L 4.00 x 4.18 x KDRULA4LE x x KDRULA5L 4.00 x 4.18 x KDRULA5LE x x KDRULB2L 5.00 x 6.00 x KDRULB2LE x x KDRULB1L 5.00 x 6.00 x KDRULB1LE x x KDRULD1L 5.75 x 7.20 x KDRULD1LE x x KDRULD2L 5.75 x 7.20 x KDRULD2LE x x KDRULC1L 5.75 x 7.20 x KDRULC1LE x x KDRULF2L 7.00 x 9.00 x KDRULF2LE x x KDRULF4L 7.00 x 9.00 x KDRULF4LE x x KDRULF3L 7.00 x 9.00 x KDRULF3LE x x , KDRULH3L 7.00 x 9.00 x KDRULH3LE x x , KDRULH2L 9.00 x x ,000 KDRULH2LE x x , KDRULH1L 9.00 x x ,150 KDRULH1LE x x , KDRULG3L 9.00 x x ,530 KDRULG3LE x x , KDRULG1L 9.00 x x ,650 KDRULG1LE x x , KDRULG2L 9.00 x x ,690 KDRULG2LE x x , KDRULJ2L 9.00 x x ,000 KDRULJ2LE x x , KDRULJ1L 9.00 x x ,200 KDRULJ1LE x x , KDRULL1L x x ,575 KDRULL1LE x x , KDRULL2L x x ,775 KDRULL2LE x x ,644 or call

5 LINE REACTORS 460V 5% IMPEDANCE, 460V PART # PART # KDRULA8H 4.00 x 4.18 x KDRULA8HE x x KDRULA1H 4.00 x 4.18 x KDRULA1HE x x KDRULA2H 4.00 x 4.18 x KDRULA2HE x x KDRULA3H 4.00 x 4.18 x KDRULA3HE x x KDRULA4H 4.00 x 4.18 x KDRULA4HE x x KDRULA5H 4.00 x 4.18 x KDRULA5HE x x KDRULB2H 5.00 x 6.00 x KDRULB2HE x x KDRULC3H 5.75 x 7.20 x KDRULC3HE x x KDRULC1H 5.75 x 7.20 x KDRULC1HE x x KDRULE2H 5.75 x 7.20 x KDRULE2HE x x KDRULF4H 7.00 x 9.00 x KDRULF4HE x x KDRULF1H 7.00 x 9.00 x KDRULF1HE x x , KDRULF2H 7.00 x 9.00 x KDRULF2HE x x , KDRULH2H 9.00 x x KDRULH2HE x x , KDRULI2H 9.00 x x ,029 KDRULI2HE x x , KDRULG3H 9.00 x x ,250 KDRULG3HE x x , KDRULG1H 9.00 x x ,488 KDRULG1HE x x , KDRULJ1H 9.00 x x ,152 KDRULJ1HE x x , KDRULL1H x x ,307 KDRULL1HE x x , KDRULL2H x x ,350 KDRULL2HE x x , KDRULL3H x x ,700 KDRULL3HE x x , KDRULL4H x x ,400 KDRULL4HE x x , KDRULL5H x x ,500 KDRULL5HE x x , KDRULL6H x x ,200 KDRULL6HE x x , or call

6 OUTPUT REACTORS/ LOW PASS FILTER COMBINATIONS Output Reactors/ Low Pass Filter Combinations installed between an AC Drive and a motor limit the magnitude of voltage spikes at the motor. The filters also protect cables and the motor's insulation from damage caused by PWM reflected waves. 460V OUTPUT REACTOR / LOW PASS FILTER COMBINATION, 460V (lbs.) PROCUCT CODE 1 3 V1K3A x 5.50 x V1K3A x 5.50 x V1K4A x 5.50 x V1K4A x 5.50 x V1K6A x 5.50 x V1K6A x 5.50 x V1K8A x 5.50 x V1K8A x 5.50 x V1K12A x 5.50 x V1K12A x 5.50 x V1K18A x 5.50 x V1K18A x 5.50 x V1K25A x 5.50 x V1K25A x 5.50 x , V1K27A x 5.50 x V1K27A x 5.50 x , V1K35A x 8.00 x V1K35A x 8.00 x , V1K45A x 8.00 x V1K45A x 8.00 x , V1K55A x 8.00 x V1K55A x 8.00 x , V1K80A x 8.00 x ,296 V1K80A x 8.00 x , V1K80A x 8.00 x ,296 V1K80A x 8.00 x , V1K110A x 8.00 x ,525 V1K110A x x , V1K130A x x ,800 V1K130A x x , V1K160A x x ,944 V1K160A x x , V1K200A x x ,106 V1K200A x x , V1K250A x x ,160 V1K250A x x , V1K305A x x ,376 V1K305A x x , V1K362A x x ,775 V1K362A x x , V1K420A x x ,200 V1K420A x x , V1K480A x x ,456 V1K480A x x , V1K600A x x ,564 V1K600A x x , V1K750A x x ,724 V1K750A x x ,600 (lbs.) or call

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives) Large Drive Variable Speed Control is Just the Beginning NEMA Franklin FastApp Firmware Pre-configured for easy operation and optimal performance PSI unit display Sleep and wake up functions Lubrication

More information

1321 Power Conditioning Products

1321 Power Conditioning Products Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R and 3RA Series Line Reactors 3 1321 Reflective Wave Reduction (RWR)

More information

Series A DC Link Chokes

Series A DC Link Chokes Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS

More information

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U Instruction Manual Supplement for FRN-C2S-2U/4U (7.5 to 20 HP) Compact Inverter 200 V series: FRN0025 to 0060C2S-2U series: FRN0013 to 0030C2S-4U Thank you for purchasing our FRENIC-Mini series of inverters.

More information

Description 1/8-7.5HP

Description 1/8-7.5HP Description 1/8-7.5HP J1000 In our pursuit to create drives optimized for variable speed needs in compact applications, the J1000 is the solution. This micro-drive is simple and reliable with Yaskawa quality.

More information

Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry; Baldor Brand; Current Rating 45 Ampere

Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry; Baldor Brand; Current Rating 45 Ampere LRAC04502 Line Reactor Baldor Electric CO. Catalog Number LRAC04502 Manufacturer Baldor Electric CO. Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry;

More information

Variable Speed Product Line

Variable Speed Product Line Variable Speed Product Line BRCPVFD R1 Variable Speed Product Line Since 1997, CentriPro has been providing variable speed pump control solutions to its customers. The first product was the Aquavar variable

More information

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS HPS CENTURION R REACTORS AND RC DV/DT FILTERS Single and Three Phase Why Choose a Line Reactor?... 98 Construction Features... 100 HPS Centurion R Reactors Specifications... 101 Part Number Guide... 102

More information

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Retain for future use. 30072-450-47A July 2002 Raleigh, NC, USA HAZARDOUS VOLTAGE Read and understand

More information

Since then, products have been introduced and expanded to include:

Since then, products have been introduced and expanded to include: ...in the beginning...baldor begins operations in St. Louis, MO. 1952 Baldor enters the world of servos (acquires Munich, Germany, and Minnesota facilities) 1990 1920 Baldor ships first adjustable speed

More information

Common Bus and Line Regeneration

Common Bus and Line Regeneration Common Bus and Line Regeneration Addressing VFD applications when Regenerative Energy is Present Steve Petersen, Drives Technical Training Yaskawa America, Inc. Variable frequency drives (VFDs) are implemented

More information

Automatic COSYS PFC. Automatic power factor correction system NEW

Automatic COSYS PFC. Automatic power factor correction system NEW Automatic COSYS PFC Automatic power factor correction system NEW cosys_178_a_1_x_cat cosys_178_a_1_x_cat appli_xxx_a  Function Your reactive energy consumption vary depending on the type and using conditions

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS KLR Series Three Phase Reactors PRODUCT SPECIFICATIONS Lifetime Warranty Performance Guarantee K-Rated, UL/ULC-Recognized; CSA-Certified 3 Phase, 600V Class Gapped Iron Core Inductor All Copper Windings

More information

BRKC-180. User s Manual and Installation Guide. Braking circuit. Contents. 1. Safety, policy and warranty.

BRKC-180. User s Manual and Installation Guide. Braking circuit. Contents. 1. Safety, policy and warranty. BRKC-180 Braking circuit User s Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3.

More information

AC Line / Load Reactors

AC Line / Load Reactors AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

VFD Best Practices: Getting the Most from Your VFD Investment

VFD Best Practices: Getting the Most from Your VFD Investment TECH TOPICS VFD Best Practices: Getting the Most from Your VFD Investment The purpose of this document is to outline best practices for successful application and installation of VFDs. Following these

More information

DBR3, 4500W, 9R, TS - BRAKING RESISTOR

DBR3, 4500W, 9R, TS - BRAKING RESISTOR 1220-0045009 - DBR3, 4500W, 9R, TS - BRAKING RESISTOR This resistor is made with coiled coil elements inside a metallic framework. The frame of the enclosure is made of galvanized steel with IP20 degree

More information

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC The Z Series Zero-Fired SCR Power Controllers 60-1200 AMPS 120-600 VAC SCR Power controllers for resistance heating applications. ROBICON 1996 Rev. 7/96 Applications Robicon s Z series power controls are

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

Technical Explanation for Inverters

Technical Explanation for Inverters CSM_Inverter_TG_E_1_2 Introduction What Is an Inverter? An inverter controls the frequency of power supplied to an AC motor to control the rotation speed of the motor. Without an inverter, the AC motor

More information

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 050516 2002 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RL Line/Load Reactors are components

More information

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

MTE AC Line / Load Reactors Price book

MTE AC Line / Load Reactors Price book Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 REACTOR SELECTION & PRICING...4 208-240 VOLT (3-PHASE)...4 400 VOLT (50 HZ) USE FOR 380-415 VOLTS...5 480 VOLT (3-PHASE) REACTOR...6

More information

RLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved.

RLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved. mtecorp.com RLW Reactors State-of the-art solution for absorbing everyday power line disturbances Smaller, lighter protection. Proven performance in the field Reliable and economical Compact and lightweight

More information

ELSEMA 240VAC Slider Control Board, SLD

ELSEMA 240VAC Slider Control Board, SLD SLD Slider Control Board ELSEMA Features For Single 240VAC Motor Built-in transformer, auto close, open only, security close & special security close Application Control an automatic door or gate with

More information

VS1PFB 230V, 50/60 Hz, 3-Phase

VS1PFB 230V, 50/60 Hz, 3-Phase Farm Duty Unit Handling Brake 200 & 575 Volt Pump and Fan Bypass AC Drive 7.5 thru 40 Hp 7.5 thru 125 Hp & Controls 230 VAC 460 VAC 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications: Pump and Fan AC Drive

More information

Automotive Grade Thin Film Chip Resistors

Automotive Grade Thin Film Chip Resistors FEATURES PRECISE TOLERANCE AND TEMPERATURE COEFFICIENT EIA STANDARD CASE SIZES (0402 ~ 2512) AEC-Q200 QUALIFIED FOR AUTOMOTIVE APPLICATIONS LOW NOISE, THIN FILM (NiCr) CONSTRUCTION TEMPERATURE RANGE -55

More information

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT 41-348.11C SA-1 Generator Differential Relay - Class 1E 2.0 CONSTRUCTION The type SA-1 relay consists of: Restraint Circuit Sensing Circuit Trip Circuit Surge Protection Circuit Operating Circuit Amplifier

More information

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks Product Selection & Application Guide Product Description GE's Thyristor Switched Harmonic Filter Banks (TSC), are custom designed

More information

ECO-6 & Installation Manual

ECO-6 & Installation Manual ECO-6 & Installation Manual For the SPA4-RFR Upgrade Kit To upgrade SPA4 amplifiers v1.00 & v1.01 to v2.0 Some sections also apply to the PA1, PA2, and PA3 14 August 2015 2015 by Ralph Hartwell Spectrotek

More information

SDC,Inc. SCR-Regenerative Ac Drive

SDC,Inc. SCR-Regenerative Ac Drive SDC,Inc WWW.STEVENSDRIVES.COM APPLICATION NOTE #: AN_REG_GEN000 EFFECTIVE DATE: 12 MAR 02 SUPERSEDES DATE: Original NO. OF PAGES: 10 SCR-Regenerative Ac Drive Using a regeneration controller with adjustable-frequency

More information

Steve Schouten. Donna Densmore

Steve Schouten. Donna Densmore March 12, 2013 2 Steve Schouten Donna Densmore 3 Mike Carter Justin Kale 4 Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality Issues Source: Emerson Industrial Automation

More information

MotorGuard. KMG High Performance Output Sine Wave Filter. Installation, Operation, and Maintenance Manual

MotorGuard. KMG High Performance Output Sine Wave Filter. Installation, Operation, and Maintenance Manual MotorGuard KMG High Performance Output Sine Wave Filter Installation, Operation, and Maintenance Manual MotorGuard KMG High Performance Output Sinewave Filter Installation, Operation, and Maintenance Manual

More information

RLW Reactors. Product Selector. Smaller. Lighter. mtecorp.com. Proven performance in the field. Reliable and economical. Compact and light-weight

RLW Reactors. Product Selector. Smaller. Lighter. mtecorp.com. Proven performance in the field. Reliable and economical. Compact and light-weight mtecorp.com RLW Product Selector Smaller. Lighter. Proven performance in the field Reliable and economical Compact and light-weight Ideal for OEMs, integrators and panel builders Our RLW Line/Load are

More information

AIR CORE REACTORS. Phoenix Electric Corporation

AIR CORE REACTORS. Phoenix Electric Corporation AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 060227 2006 MTE Corporation Important User Information NOTICE MTE Series RL Line/Load Reactors are components

More information

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3. 41-348.1H Type SA-1 2.1. RESTRAINT CIRCUIT The restraint circuit of each phase consists of a center-tapped transformer, a resistor, and a full wave rectifier bridge. The outputs of all the rectifiers are

More information

2018 Product Guide. Effective April 20, Revision 1.3 Copyright 2018, TCI, LLC All Rights Reserved

2018 Product Guide. Effective April 20, Revision 1.3 Copyright 2018, TCI, LLC All Rights Reserved 2018 Product Guide Effective April 20, 2018 Copyright 2018, TCI, LLC All Rights Reserved Terms & Conditions of Sales Minimum Orders No minimum order required. Payment Terms If the customer is located within

More information

DYNAMIC BRAKING RESISTORS

DYNAMIC BRAKING RESISTORS DYNAMIC BRAKING RESISTORS Dynamic braking is the simplest and very widely used method of braking a load driven through a d.c motor as it involves no wear and tear unlike with mechanical brakes. For dynamic

More information

MOTOR PROTECTION Sine Wave 2-8 khz Series A Filter Table of Contents

MOTOR PROTECTION Sine Wave 2-8 khz Series A Filter Table of Contents MOTOR PROTECTION Table of Contents Application & Selection Guides TR-1701-2 Selection: 440-480 VAC TR-1701-3 550-600 VAC TR-1701-4 Options Selection: Product Specification Model Number Code System Mechanical

More information

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific

More information

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER Chassis Inverter power Rated input Rated output Battery pack Safeties Environment Others Input Voltage Lower Limit Input Voltage Upper Limit Power Input Current Output Voltage Output accuracy Transient

More information

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977 NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977 1. GENERAL. 1.1 These PR notes supersede notes PR 2133 and should only be used in conjunction with

More information

3A L.D.O. VOLTAGE REGULATOR (Adjustable & Fixed)

3A L.D.O. VOLTAGE REGULATOR (Adjustable & Fixed) FEATURES Output Current of 3A Fast Transient Response 0.04% Line Regulation 0.2% Load Regulation Internal Thermal and Current Limiting Adjustable or Fixed Output oltage(1.5, 1.8, 2.5, 3.3, 5.0) Surface

More information

ELG4125: Flexible AC Transmission Systems (FACTS)

ELG4125: Flexible AC Transmission Systems (FACTS) ELG4125: Flexible AC Transmission Systems (FACTS) The philosophy of FACTS is to use power electronics for controlling power flow in a transmission network, thus allowing the transmission line to be loaded

More information

Chapter 1: Getting Started User Manual Overview...1 2

Chapter 1: Getting Started User Manual Overview...1 2 Getting Started Chapter 1 Table of Contents Chapter 1: Getting Started User Manual Overview.........................................1 2 Overview of this Publication.........................................

More information

HASTINGS INSTRUMENTS. AVG and AVC MODULE

HASTINGS INSTRUMENTS. AVG and AVC MODULE HASTINGS INSTRUMENTS AVG and AVC MODULE TELEDYNE BROWN ENGINEERING Hastings Instruments P.O. Box 1436 Hampton, Virginia 23661 U.S.A. MANUAL 137-0596 Rev.B ISO 9001 C E R T I F I E D page 1 page 2 Contents

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

AC Drives Selection Guide

AC Drives Selection Guide AC Drives Selection Guide Class 8839 CATALOG CONTENTS Description.................................................... Page Specifications..................................................... 3 Open Style

More information

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST

More information

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac. Solid State Relays Vdc Input/ Output, Input/ Output High Reliability Shown smaller than actual size ac Controlled used with Controller with dc Voltage Driver Output L Typically ac Controlled used with

More information

ELECTRICAL POWER and POWER ELECTRONICS

ELECTRICAL POWER and POWER ELECTRONICS Introduction to ELECTRICAL POWER and POWER ELECTRONICS MUKUND R PATEL (cj* CRC Press Taylor & Francis Group Boca Raton London New York CRC Press is an imprint of the Taylor & Francis Croup, an informa

More information

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR Current Integrated 300 Watt Power Supply 10 Amperes/phase Maximum Operating 7 Amperes/phase Standstill motor current Adjustable Base

More information

2.2.5 Connection of stand-alone option units

2.2.5 Connection of stand-alone option units 2.2.5 Connection of stand-alone option units INSTALLATION AND IRING The inverter accepts a variety of stand-alone option units as required. Incorrect connection will cause inverter damage or accident.

More information

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load Transportation Products SL Series - Application Notes General Application Notes vin 2 ft. 14 AWG The SL family of power converters, designed as military grade standalone power converters, can also be used

More information

1.5A L.D.O. VOLTAGE REGULATOR (Adjustable & Fixed) LM1086

1.5A L.D.O. VOLTAGE REGULATOR (Adjustable & Fixed) LM1086 FEATURES Output Current of 1.5A Fast Transient Response 0.2% Line Regulation 0.3% Load Regulation Internal Thermal and Current Limiting Adjustable or Fixed Output oltage(1.5, 1.8, 2.5, 3.3, 5.0) Surface

More information

L300P Inverter Specifications

L300P Inverter Specifications L300P Inverter Specifications Tables for 200V class inverters Note that General Specifications on page 1 9 covers all L300P inverters, followed by footnotes for all specifications tables. Seven 200V models

More information

HYBRID STEREO POWER AMPLIFIER

HYBRID STEREO POWER AMPLIFIER 993 HYBRID STEREO POWER AMPLIFIER Designed & made in London, England 2 THE NEW 993 HYBRID STEREO POWER AMPLIFIER SHOWCASES TRILOGY S MASTERY OF ALL AUDIO TECHNOLOGIES, BECAUSE THE BEST DESIGN CHOICES CAN

More information

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with a patented liquid-cooling

More information

HPS Centurion R Reactor. Why Choose a Reactor? Connection Diagram

HPS Centurion R Reactor. Why Choose a Reactor? Connection Diagram HPS Centurion R Reactor The new HPS Centurion R reactor provides a unique blend of improved performance and reliability while reducing the product footprint. HPS Centurion R reactors deliver protection

More information

55 Watt K Triple Series DC/DC Converters

55 Watt K Triple Series DC/DC Converters Features Very Low Noise, < mv P-P Maximum PCB Mounting with Optional Heat Sink or Chassis Mount Versions Efficiencies to 87 Common and Differential Mode Input Filtering Remote Sense On + Volt Output Single

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Ultra Wide Input Ranges (936Vdc, 2060Vdc) 4 Efficiency 85% (typ.) 4 Independently Isolated Outputs 4 SixSided Shielded Case 4 Remote On/Off Control 4 Continuous

More information

Application. Battery. Public Grid GS HYBRID INVERTER

Application. Battery. Public Grid GS HYBRID INVERTER GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

VCE Systems Engineering

VCE Systems Engineering VCE Systems Engineering Mechanical formula and Electrotechnology formula and worked examples - speed (m/s) or (ms distance (m) metre time (s) second ) metre per second speed = distance time A car travels

More information

Series 22H Line Regenerative Vector Drive

Series 22H Line Regenerative Vector Drive Series 22H Line Regenerative Vector Drive Design Specifications Process follower ±5VDC 0-5 VDC, ±10VDC, 0-10 VDC, 4-20mA, digital via keypad or optional RS232/485 Linear or S-curve deceleration Controlled

More information

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / / Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.

More information

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING CHAPTER ERROR MESSAGE AND TROUBLESHOOTING VFD-V Series The AC drive has a comprehensive fault diagnostic system that includes various alarms and fault messages such as over-voltage, low-voltage and over-current.

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 200 Vdc 4 Low Profile 4 High Regulation 4 Ultra Wide Input Ranges (9-36Vdc, 20-60Vdc, 36-72Vdc) 4 1000 Vdc Output Isolation 4 Continuous Short Circuit

More information

2 SLR Series Line Reactors... 50

2 SLR Series Line Reactors... 50 Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...

More information

Center Winder Specification

Center Winder Specification Center Winder Specification Bump Roll Edge Guide Photo Eye 2000 Ft/ Min Dancer Arm Center Winder Overview Winding is simply a rotational means to take up and package material for more efficient handling

More information

REAP CARE ROTATING ELECTRICAL ASSET PROGNOSTIC CARE

REAP CARE ROTATING ELECTRICAL ASSET PROGNOSTIC CARE REAP CARE ROTATING ELECTRICAL ASSET PROGNOSTIC CARE Longevity approach Assess & Avoid Failures ROTATING ELECTRICAL ASSET PROGNOSTIC CARE Failure Statistics Failure Statistics Failure Statistics BEARING

More information

Modifiable TITAN Horizontal Motors Accessories and Modifications

Modifiable TITAN Horizontal Motors Accessories and Modifications 36. Rotor, Standard And Optional Construction Standard rotor construction of 449, 5000 and 5800 frame TITAN products is typically die-cast aluminum. 720 RPM and slower is typically fabricated aluminum.

More information

GS2 Series - Introduction

GS2 Series - Introduction GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase

More information

Electrical Drives I. Week 11: Three phase Induction Motor Starting

Electrical Drives I. Week 11: Three phase Induction Motor Starting Electrical Drives I Week 11: Three phase Induction otor Starting Starting Problem Definition: ' I r Rs Vs 2 R ' r S 2 Xeq At S=0 and S=1, thus the current can be determined as: ' I r st Vs 2 ' Rs Rr Xeq

More information

XLM 62V Energy Storage Module

XLM 62V Energy Storage Module Technical Note 10406 XLM Energy Storage Module XLM 62V Energy Storage Module Introduction The XLM energy storage modules are self-contained energy storage devices comprised of twenty-three individual supercapacitor

More information

SECTION MOTOR CONTROLLERS

SECTION MOTOR CONTROLLERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph

More information

7. How long must a 100-watt light bulb be used in order to dissipate 1,000 joules of electrical energy? 1) 10 s 3) 1,000 s 2) 100 s 4) 100,000 s

7. How long must a 100-watt light bulb be used in order to dissipate 1,000 joules of electrical energy? 1) 10 s 3) 1,000 s 2) 100 s 4) 100,000 s 1. Which quantity must be the same for each component in any series circuit? 1) power 3) current 2) resistance 4) voltage 2. A student needs a 4-ohm resistor to complete a circuit. Only a large quantity

More information

Practical Variable Speed Drives and Power Electronics

Practical Variable Speed Drives and Power Electronics Practical Variable Speed Drives and Power Electronics Malcolm Barnes CPEng, BSc(ElecEng), MSEE, Automated Control Systems, Perth, Australia AMSTERDAM BOSTON HEIDELBERG LONDON. NEW YORK OXFORD PARIS SAN

More information

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds Digital Soft Start Controls Soft Starters & 9 thru 900 s 208-460V 50/60 Hz. 9 thru 900 s 208-575V 50/60 Hz. Farm Duty Applications: Controlled ramp start and stop, minimize spillage in material handling,

More information

25 to 30 Watt XW Single Series DC/DC Converters

25 to 30 Watt XW Single Series DC/DC Converters Features 4: Input Voltage Range Low Noise, Highly Regulated Efficiencies to 4 at Full Load No Derating to C Case Temperature Six-Sided Continuous Shielded, Low Thermal Gradient Copper Case Minimum Input

More information

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES INVERTER SERIES Varispeed E VARISPEED E YASKAWA INVERTER DRIVE TECHNOLOGY Contents Content Page 2 Experience & Innovation A leader in Drives technology Page 3 Specifications Experience & Innovation For

More information

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications LiquiFlo AC Drives A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with

More information

Motor Drives Training System (Stand-Alone, 120 V Version) (8036-C0)

Motor Drives Training System (Stand-Alone, 120 V Version) (8036-C0) Motor Drives Training System (Stand-Alone, 120 V Version) 581526 (8036-C0) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 11/2018 Table of Contents General Description 2 List of Equipment 2 List

More information

BPS-v4 Technical Reference S-CAB 11 volt, 1 amp battery power supply

BPS-v4 Technical Reference S-CAB 11 volt, 1 amp battery power supply BPS-v4 Technical Reference S-CAB 11 volt, 1 amp battery power supply This fourth generation BPS battery power supply is intended for applications requiring up to 1 amp from a small package. Conceptually,

More information

ALTIVAR 58 AC Drives

ALTIVAR 58 AC Drives Class 8806 / 8839 / 8998 CONTENTS Schneider Electric Brands Page ALTIVAR 58 AC Drives............................................... 3 Drives Overview...................................................

More information

Variable Frequency Drives

Variable Frequency Drives We Make Energy Engaging Variable Frequency Drives Questline Academy Meet Your Panelist Mike Carter questline.com 2 Contents Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality

More information

POWER SUPPLY FOR ASYNCHRONOUS MOTORS

POWER SUPPLY FOR ASYNCHRONOUS MOTORS White Paper 07 2010 POWER SUPPLY FOR ASYNCHRONOUS MOTORS Author: Franck Weinbissinger GENERAL INFORMATION Three-phase asynchronous motors are very robust and low-maintenance electrical machines widely

More information

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Single or Double 240VAC motor control for domestic and industrial gates and doors. COBO30 Double 240V Motor Drive Controller Features For 240Volt Motors Auto Closing Open Only Security Closing and Extended Lock Pulse (user selectable) Travel Timer Push Button Input Photo Cell Input Option

More information

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 INTRODUCTION The Aquavar Intelligent Pump Controller from utilizes an all new Aquavar platform, and combines it with over 20 years of

More information

Power System Solutions (PSS)

Power System Solutions (PSS) About Power System Solutions mission The Power System Solutions Mission Statement To achieve customer satisfaction by providing innovative solutions to improve upon power quality, energy efficiency, and

More information

Western Canada BLRBAC Conference Selecting the Right Power Supply and Electrode for a Recovery Boiler ESP

Western Canada BLRBAC Conference Selecting the Right Power Supply and Electrode for a Recovery Boiler ESP Western Canada BLRBAC Conference Selecting the Right Power Supply and Electrode for a Recovery Boiler ESP April 15, 2015 John A. Knapik Application Engineer B&W Preciptech Overland Park, KS jaknapik@babcock.com

More information

MBS 1200 and MBS 1250

MBS 1200 and MBS 1250 Data sheet OEM Pressure Transmitters for heavy-duty applications MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic applications. The programme

More information

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should

More information

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction Table of Contents Output specification Input specification General specification Environmental specifications EMC characteristic curves Output voltage adjustment Input source impedance Output over current

More information

Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies

Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies Application Techniques Original Instructions Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies Important User Information Read this document and the documents listed in the additional

More information