Experiences in a Motor Protection Retrofit
|
|
- Leon Lambert Neal
- 5 years ago
- Views:
Transcription
1 Special Feature by Kyle Craig, Ontario Power Generation Amy Sinclair, Schweitzer Engineering Laboratories, Inc. Experiences in a Motor Protection Retrofit Introduction The initial stage of any project is often the business case development. This article outlines the business case for the motor protection retrofit at a large thermal generation plant. The key protection improvements for this installation are reviewed including the advantages of the thermal model and the application of the slip-dependent thermal model. Silver Migration The existing auxiliary relay cases in the motor protection panels have proven to be susceptible to silver migration. Silver migration is the ionic movement of silver between two potentials. The moisture present in the humid air of the thermal plant acts as an electrolyte. The silver transfers from the contacts of an auxiliary relay onto the terminals of its mounting case. When the silver migrates so that two terminals are bridged, protection failures can occur. The plant has recorded several false trips during the past few years. Background and Issues Maintenance Schedule and Spare Parts The existing electromechanical thermal-replica motor protection and interposing relays are well beyond their service life, obsolete from a manufacturing perspective, and have limited spare parts. The plant requirement for maintenance on this existing equipment is to calibrate and complete functional tests every five years. Historically, the calibration on a single thermal-replica motor protection and interposing relay scheme takes a full day. There are a total of 90 motor protection schemes within the facility. Digital relays are self-checking and do not require the same extent of calibration and functional testing. Digital relays are capable of recording and storing event reports, sequential event report data, motor start reports, motor start trending, and motor operating statistics, as well as alarming for self-diagnosed failures. Digital relays are continuously self-testing and reporting operating status. Only functional testing is required after the original in-service commissioning is complete. This functional testing takes less than 30 minutes. The cycle for the digital relay functional testing corresponds to the current Northeast Power Coordinating Council requirements for digital relay reverification. Figure 1 Auxiliary Relay Case Showing Silver Migration The new digital relays have internal timers, internal latches, digital inputs, and enough output contacts so that the auxiliary relays and auxiliary relay cases are no longer required. Digital Recording and Data The plant currently has no digital fault recording equipment on the 4 kv motors or 4 kv bus. The new digital relays sample and store analog and digital data. This provides the operating data required to quickly determine what caused a trip without completing all the detailed tests that were Fall 2010 NETA WORLD 1
2 required previously to troubleshoot any motor protection trips. Following a motor protection trip from existing electromechanical protection, it was a requirement to functional test the protection. With the stored digital data from the new digital relays, this is no longer a requirement. The new digital relays also provide motor operating statistics and motor trend reports. These files can be used to provide an early warning regarding changes in motor start current, thermal capacity used during starting, and motor start time. As an example, these types of detailed data can indicate gradually increasing load torque, which could lead to an unwanted motor trip. Analyzing these types of data can assist with planning motor maintenance schedules and help to avoid unplanned downtime. Thermal Model and Motor Cooling The existing motor protection relies on operators and operating procedures to determine the correct time between starts and prevent damage to motors caused by frequent multiple motor starts. The new digital relays provide a lockout feature to prevent motor starting until the thermal element calculates that there is enough available thermal capacity to allow a start without tripping. The protection engineer sets the rotor and stator thermal capacity used during starting, and the relay provides a lockout until the motor has cooled to the defined capacity. High-Inertia Loads The standby boiler feed pump (SBFP) and the forced draft (FD) fan motors each have starting times considerably longer than their safe stall times. The existing electromechanical thermal-replica protection relays have been desensitized to accommodate the long starting times. The plant had used speed switches in the past, but over time the speed switches proved to be too unreliable and were retired. The probability of a motor stall is low, but the consequence of a failure is higher. The failure of an FD fan motor would cause a forced derating to half load until the motor was repaired. Repair for this 2,300 hp motor could take one week to three months, depending on the severity of the motor damage. If both SBFP motors are unavailable, the generator will be on forced outage until the motor is repaired or a spare unit is made available. Repair or replacement of this 5,500 hp motor could take from one week to three months. Alternatives and Economic Analysis The base case considered for this business case is status quo. This plan could lead to the failure of a critical motor that could leave a main unit unavailable or derated for one day to three months, depending on the severity of the failure. This option will still cost $104,000 (Canadian) over the next five years while the auxiliary relay cases are replaced per an existing program. Because it is not practical or possible to replace all the auxiliary cases at once, nuisance motor tripping may be an issue because of the silver migration. All costs associated with this alternative are avoided by upgrading all of the 4 kv motor protection schemes. Alternative 1: Upgrade 4 kv Motor Protection on Critical Motors Only This option addresses the spare parts availability, system reliability problems, and the silver migration issue on half of the motor protection schemes. The auxiliary relay cases on the motor protection schemes that are not changed will still have to be replaced as scheduled. As the original 35-yearold motor protection schemes left on the noncritical motors age, more failures will occur. Although these failures will not affect the availability of a generator unit, motor protection failures could cause costly motor damage and will eventually require upgrading the relays. Alternative 2: Delay Work One Year Delaying the project will not immediately address the spare parts availability and system reliability. The frequency of motor protection calibration and troubleshooting to verify proper operation will only increase as the equipment continues to age. Similar to the base case, delaying the project will increase the probability of a forced outage or equipment damage. Alternative 3: Upgrade 4 kv Motor Protection The recommended and accepted proposal is to replace all existing 4 kv motor protection relays and the auxiliary relay cases with new digital relays that meet the motor protection requirements. The new protective relays provide the following: Protection for motors with start times longer than their safe stall time. Thermal lockout for multiple start protection. Improved protection for motors previously protected with 51 elements. Data acquisition and troubleshooting using the digital data stored in the relay. The photos in Fig. 2 show the installation of the digital relays. Installation costs were kept to a minimum by taking advantage of existing wiring. The photos show that generally only internal panel wiring required modification. 2 NETA WORLD Fall 2010
3 The relay used for this retrofit uses a thermal model that calculates motor slip during start. During the start of an induction motor, the rotor resistance changes from a high locked rotor value to a low running value. This motor protection relay uses voltage and current to calculate the slip-dependent rotor resistance that enables the calculation of rotor temperature while it varies during a motor start. The details of this thermal model can be reviewed in [2]. In summary, four quantities are required by the slipdependent thermal model in order to calculate the locked rotor resistance and rotor resistance at rated speed. These four quantities are the locked rotor torque (LRQ), the locked rotor current in per unit (I L ), the full-load speed (FLω), and the synchronous speed (Synω). The locked rotor resistance R M is calculated directly from LRQ in per unit of rated torque and the locked rotor current in per-unit current. Locked Rotor Resistance (1) The rotor resistance at rated speed R N is calculated directly from FLω and Synω. The rotor resistance at rated speed is the motor full-load slip (FLS). Rotor Resistance at Rated Speed (2) At the instant of motor starting, the relay calculates the motor resistance by sampling the positive-sequence voltage V 1 (cyc) and the positive-sequence current I 1 (cyc) at a selected initial cycle. The real part of this impedance is the initial motor resistance R P. Initial Motor Resistance (3) Now, with a sampled value for R P and the locked rotor resistance R M, the stator resistance can be calculated, where A = 1.2, a constant shown in [2]. Stator Resistance (4) Figure 2 Motor Protection Retrofit Motor Starting and Calculating Motor Slip Most digital motor protection relays calculate the heating in the motor by measuring the current. The relay calculates the heating in terms of thermal capacity. The thermal capacity is defined where zero percent is completely cooled and 100 percent is the limit threshold. The thermal capacity is accumulated based on measured current so that during motor starting, the protection is essentially an I 2 t element, with the maximum starting time limited by the hot motor safe stall time. Problems arise when starting motors with high-inertia loads, as the time required to start the motor may approach or even exceed the hot safe stall time [1]. he slip, shown in (6), is a function of the changing motor input resistance, shown in (5), the previously calculated locked rotor resistance R M, the rotor resistance at rated speed R N, and the stator resistance R S. The motor input resistance is measured and updated every processing interval. The motor slip is calculated every two cycles. Motor Resistance (5) Motor Slip (6) Positive-Sequence Rotor Resistance (7) Fall 2010 NETA WORLD 3
4 A comparison of the standard I 2 t starting element, which assumes a constant rotor resistance, with the slip-dependent starting element shows that the slip-dependent model simply includes the slip-dependent rotor resistance in the heat source of the thermal model [2] [3]. Settings and Testing for 5,500 hp Standby Boiler Feed Pump The available motor data provided most of the information required to calculate the settings for the digital relay. Full-load amperes (FLA) was set to 685 A. The setting for locked rotor current was increased from 4.82 FLA to 5.5 FLA (an increase of roughly 300 A) as suggested by the company that rebarred the rotor to a larger style rotor bar. The stator was not modified. Service factor (SF) was set to 1.05 as per the motor ratings. FLS was calculated as: (FLS = 1 nr/ns) (FLS = /3600 = ). The hot safe stall time was set at 9.0 seconds. The following settings were applied to the relay: The following settings were applied to the relay: The applied settings used a hot safe stall time that was less conservative than suggested at 8.0 seconds. Fig. 4 is the start report for the revised settings. During the 11-second start, the rotor temperature reaches 75 percent of the maximum allowed temperature. The revised LRQ quantity results in a new stored constant for locked rotor resistance R M (1) and also results in a revised calculated value for R S (4). The stator resistance R S is dependent on R M and R P, as per (3). The relay measures and calculates R S during every start. Fig. 3 is the motor start report for this 5,500 hp SBFP. The traces show the motor current, terminal voltage, rotor temperature in per unit of the trip value or thermal capacity, and slip. Figure 4 SBFP Motor Start Report, LRQ = 0.7, Start 1 The motor was started twice more with LRQ at 0.7 and the hot safe stall time at 8.0 seconds. Fig. 5 is a motor start report for Start 3 of the 5,500 hp SBFP with the revised settings. Note that on this repeated start, the traces show the normal motor current and relay terminal voltage. However, in this case, the calculated slip remains at 1.0 for an extended time. The rotor resistance remains at R M for this time, and the thermal capacity reaches 100 percent. Figure 3 SBFP Motor Start Report, LRQ = 0.96 Fig. 3 shows that the slip remained at 1.0 for the entire start. Because of the high-inertia load, the motor start time is longer than the hot safe stall time, and the thermal capacity reaches 100 percent. When the calculated slip exceeds 1.0, the relay assigns a slip of 1.0 and calculates the temperature rise using the high locked rotor resistance. Following a review of the motor start data, the motor manufacturer suggested a revised LRQ of 0.7 per unit of rated torque and a hot safe stall time of 6.5 seconds. Figure 5 SBFP Motor Start Report, LRQ = 0.7, Start 3 4 NETA WORLD Fall 2010
5 Figure 7 SBFP Motor Start Report, August 2009 Figure 6 Varying Starting Resistance During Start 3 A detailed examination of the digital data provided by the relay shows that although the current and voltages are as expected for motor starting, there is a variation in the positive-sequence voltage V 1 (cyc) and the positive-sequence current I 1 (cyc). Fig. 6 shows a plot of the resulting varying starting resistance over the first eight cycles of the motor start. During the first few cycles of starting, the rotor resistance is at its initial value R M, and the slip S is 1.0. Thus, the stator resistance R S can be determined using the initial measured resistance R P in (4). The initial cycle at which R P is measured is not critical when the initial resistance remains constant after a 1- or 2-cycle settling time. This is not the case for this 5,500 hp SBFP, as seen in Fig. 6. To account for this varying starting resistance, the relay software was modified to select the minimum value of R P over the first few cycles. Fig. 7 shows a motor start report for this 5,500 hp SBFP with no new settings changes and relay software that is selecting the minimum value of R P over the first few cycles. The traces show the motor current, relay terminal voltage, rotor temperature in per unit of the trip value or thermal capacity, and slip. This motor start report shows that as the slip decreases, the calculated rotor resistance is decreasing as the motor accelerates. During the 11-second start, the rotor temperature reaches 89.5 percent of the maximum allowed temperature, while the motor takes a full three seconds more than the hot safe stall time of eight seconds to successfully start. The Unit 4 SBFP motor protection relay has been in service since August The motor start trend report in Fig. 8 shows consistent start data in terms of average starting time and thermal capacity used for the motor. The starting conditions are clearly very consistent for this Unit 4 SBFP; otherwise, there would have been more variation in the percent thermal capacity. An increase in percent thermal capacity over time could indicate a gradually increasing load torque. Figure 8 Motor Start Trend Report for Unit 4 SBFP Conclusions Motor protection at this plant has been enhanced with the use of digital relays. The slip-dependent thermal model protects the motors while allowing for long acceleration times. The digital relay provides supervision to prevent motor starting until the motor thermal capacity has enough available starting capacity and to prevent damage to motors caused by frequent multiple motor starts. The motor start reports and monthly trend data in the relays can be used to monitor changing starting conditions. The event reports and motor start reports provide data that can be used to enhance the settings and improve the motor protection, as well as confirm a valid protection operation without the need to complete a full protection reverification. Fall 2010 NETA WORLD 5
6 Replacement of the existing 4 kv motor protection relays and the auxiliary relay cases with new digital relays provides the following benefits: Ensures reliable protection for the motors. Removes the safety hazard associated with a catastrophic failure of a large piece of rotating equipment. Reduces the risk associated with equipment failure and silver migration-induced trips. Eliminates the maintenance time spent calibrating each relay. Removes the need to replace auxiliary relay cases. References P. Whatley, M. Lanier, L. Underwood, and S. Zocholl, Enhanced Motor Protection With the Slip-Dependent Thermal Model: A Case Study, proceedings of the 34th Annual Western Protective Relay Conference, Spokane, WA, October S. E. Zocholl, Tutorial: From the Steinmetz Model to the Protection of High Inertia Drives, proceedings of the 33rd Annual Western Protective Relay Conference, Spokane, WA, October S. E. Zocholl, AC Motor Protection, Schweitzer Engineering Laboratories, Inc., Kyle Craig received his BEng in electrical engineering from Carleton University, Ottawa, Canada, in 2004 and his MEng in electrical power engineering from the University of Waterloo, Waterloo, Canada, in He joined Ontario Power Generation in 2004 as a grad engineer trainee at Lennox GS in Kingston, Ontario. In 2005, he became a thermal station engineer at Lennox GS with a focus on project management and protective relaying. He has been registered as a Professional Engineer in Ontario since Amy Sinclair received her BSc in electrical engineering from Queen s University, Kingston, in She joined Ontario Hydro in 1989, working for ten years as a protection and control engineer in the areas of design, operations, and project management. In 2000, she joined ELECSAR Engineering as a project manager with a focus on protective relaying and substation design. Since December 2006, she has been employed with Schweitzer Engineering Laboratories, Inc. as a field application engineer, located in Chatham, Ontario. She has been registered as a Professional Engineer of Ontario since NETA WORLD Fall 2010
Enhanced Motor Protection With the Slip-Dependent Thermal Model: A Case Study
Enhanced Motor Protection With the Slip-Dependent Thermal Model: A Case Study Patrick Whatley Plant Power and Control Systems, LLC Mark Lanier, Lee Underwood, and Stan Zocholl Schweitzer Engineering Laboratories,
More informationMotor Protection Fundamentals. Motor Protection - Agenda
Motor Protection Fundamentals IEEE SF Power and Energy Society May 29, 2015 Ali Kazemi, PE Regional Technical Manager Schweitzer Engineering Laboratories Irvine, CA Copyright SEL 2015 Motor Protection
More informationCase Study on On EHV Circuit Breaker Flashover NTPC-SINGRAULI
Case Study on On EHV Circuit Breaker Flashover AUTHORS: B. K. SINGH (AGM-ELECT) S.C.SINGH (SUPDT-ELECT) MANOJ SHARMA (Dy SUPDT-ELECT) ANAND PANDEY (ENGR-ELECT) BREAKER-FLASHOVER There has been a rising
More informationLow and medium voltage service. Power Care Customer Support Agreements
Low and medium voltage service Power Care Customer Support Agreements Power Care Power Care is the best, most convenient and guaranteed way of ensuring electrification system availability and reliability.
More informationDER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.
Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.3, 5/16/18 1.0 Scope This document is currently limited in scope to inverter interfaced PV installations
More informationA Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design
A Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design Presented at the 2018 Transmission and Substation Design and Operation Symposium Revision presented at the
More informationHydro Plant Risk Assessment Guide
September 2006 Hydro Plant Risk Assessment Guide Appendix E8: Battery Condition Assessment E8.1 GENERAL Plant or station batteries are key components in hydroelectric powerplants and are appropriate for
More informationA REPORT TO THE BOARD OF COMMISSIONERS OF PUBLIC UTILITIES. Electrical. Mechanical. Civil. Protection & Control. Transmission & Distribution
A REPORT TO THE BOARD OF COMMISSIONERS OF PUBLIC UTILITIES Electrical.1_ UFSS#p A:_. DAVID/ IC, L re Mechanical Civil Protection & Control an LAND& 4^ Transmission & Distribution Telecontrol System Planning
More informationModular Standardized Electrical and Control Solutions for Fast Track Projects
Modular Standardized Electrical and Control Solutions for Supporting fast track projects ABB is the leading supplier of electrical and control equipment for power plants. The company offers a comprehensive
More informationISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements
Applicability 1 Section 502.3 applies to: the legal owner of a generating unit directly connected to the transmission system with a maximum authorized real power rating greater than 18 MW; the legal owner
More informationHybrid DC-DC-AC Main Drive for ILVA, Taranto Finishing Mill
Hybrid DC-DC-AC Main Drive for ILVA, Taranto Finishing Mill Michael A DeCarli TM GE Automation Systems, LLC 2060 Cook Drive Salem, VA 24153, USA Tel: 540-283-2118 Fax: 540-283-2395 E-mail: Michael.DeCarli@TMEIC-GE.com
More information3.2. Current Limiting Fuses. Contents
.2 Contents Description Current Limiting Applications................. Voltage Rating.......................... Interrupting Rating....................... Continuous Current Rating................ Fuse
More informationDynamic Study of Bonaire Island Power System: Model Validation and Project Experience
Dynamic Study of Bonaire Island Power System: Model Validation and Project Experience Y. Sun 1, 2,*, W. G. Kuijpers 3, E. C. W. de Jong 1,2, and H. Pustjens 3 1 Electrical Energy System, Eindhoven University
More informationBREAKER FAILURE PROTECTION
29 th Annual HANDS-ON RELAY SCHOOL March 12-16, 2012 BREAKER FAILURE PROTECTION Brent Carper, PE Protection & Integration Engineer brent.c@relayapplication.com OUTLINE Protection System Failures and Breaker
More informationGrounding Of Standby & Emergency Power Systems
July / August 2007 ELECTRICAL LINE 53 Grounding Of Standby & Emergency Power Systems By Andrew Cochran Power continuity is essential in many industrial and commercial installations where a trip out due
More informationSteam Turbine Seal Rub
Steam Turbine Seal Rub Date : November 19, 2014 Steam Turbine Seal Rub Vibration data helps to identify a steam turbine seal rub. Sotirios Christofi Deputy Manager, Head of Mechanical Maintenance, Thessaloniki
More informationFunctional Overview and Operating Principles for the AR-OH and AR360 Overhead AutoRANGER Fault Indicators
WHITE PAPER Functional Overview and Operating Principles for the AR-OH and AR360 Overhead AutoRANGER Fault Indicators Tyson Salewske and Anthony Patenaude INTRODUCTION The purpose of this document is to
More informationTransformer Protection
Transformer Protection Course No: E01-006 Credit: 1 PDH Andre LeBleu, P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 info@cedengineering.com
More informationImproving Breaker Failure Protection for Generator Applications
1 Improving Breaker Failure Protection for Generator Applications Greg Hataway and Jonathan Ellison, PowerSouth Energy Cooperative Michael Thompson, Schweitzer Engineering Laboratories, Inc. Abstract The
More informationLARSEN & TOUBRO LIMITED TYPICAL SCHEME FOR PROTECTION OF SYNCHRONOUS MOTORS
LARSEN & TOUBRO LIMITED TYPICAL SCHEME FOR PROTECTION OF SYNCHRONOUS MOTORS R.Seshadri Larsen & Toubro Limited Mysore works 1.0 GENERAL DETAILS 1.1 Synchronous Motors: Synchronous motors come in large
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationCost Benefit Analysis of Faster Transmission System Protection Systems
Cost Benefit Analysis of Faster Transmission System Protection Systems Presented at the 71st Annual Conference for Protective Engineers Brian Ehsani, Black & Veatch Jason Hulme, Black & Veatch Abstract
More informationOKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2017 RELIABILITY SCORECARD
OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2017 RELIABILITY SCORECARD May 1, 2017 Table of Contents 1.0 Introduction...3 2.0 Summary...3 3.0 Purpose...3 4.0 Definitions...4 5.0 Analysis...5
More informationSource-Side Fuse/Load-Side Recloser Coordination
How to Coordinate ransformer Primary-Side Fuses with Feeder Reclosers Using Coordinaide M he S&C Protection and Coordination Assistant Part I: Conservative Method his is the first in a series of articles
More informationWe trust the foregoing is satisfactory. If you have any questions or comments, please contact the undersigned.
\ newfoundland labrador hydro a nalcor energy company Hydro Place. 00 Columbus Drive. P.O. Box 00. St. John's. NL Canada AB K t. 0..00 f. 0..00 www.nh.nl.ca December, 0 The Board of Commissioners of Public
More informationUBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit
More informationlectronic starter for single phase duction motor
lectronic starter for single phase duction motor PROJECT NO: 104 SUPERVISOR: DR. WEKESA EXAMINER: PROF MANG OLI Prepared by: GITONGA HILDA WANJIKU- F17/39921/2011 PROJECT OUTLINE 1. Project Objective 2.
More informationApplication Note: Protection of Medium-Power Motors With SIPROTEC Compact 7SK80
Application Note: Protection of Medium-Power Motors With SIPROTEC Compact 7SK80 Motor settings using the SIPROTEC Compact motor protection relay 7SK80 is explained below. Information is given on how to
More informationApplication Note. First trip test. A circuit breaker spends most of its lifetime conducting current without any
Application Note First trip test A circuit breaker spends most of its lifetime conducting current without any operation. Once the protective relay detects a problem, the breaker that was idle for maybe
More informationImpact of Distributed Energy Resources on Transmission System Reliability
S E P T E M B E R 1 3, 2 0 1 8 W E B I N A R Impact of Distributed Energy Resources on Transmission System Reliability National Council on Electricity Policy (NCEP) Alan McBride D I R E C T O R, T R A
More informationEXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR
EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR Velimir Nedic Thomas A. Lipo Wisconsin Power Electronic Research Center University of Wisconsin Madison
More informationDual Power. Protection. Protection
54 Fault Clearing Systems by Damien Tholomier., AREVA T&D Automation, Canada Dual Power Single Battery What if it? Short circuits and other abnormal power system conditions are very rear, but may result
More informationVariable Frequency Drive Basics
Variable Frequency Drive Basics Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Variable Frequency Drives are
More informationCONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation
CONNECTION ASSESSMENT & APPROVAL PROCESS ASSESSMENT SUMMARY Applicant: Project: Cardinal Substation Modification of 115kV Substation CAA ID: 2002 EX071 Long Term Forecasts & Assessments Department\ Consistent
More informationGuideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society
Guideline No.: E-07(201712) E-07 TRANSFORMERS Issued date: December 26, 2017 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection
More informationSeabrook Substation Reliability Improvement Project
New England Division Seabrook Substation Reliability Improvement Project 1. Project Summary Description Seabrook Substation is critical to ISO-New England as a Pool Transmission Facility, to grid availability
More informationBased on the findings, a preventive maintenance strategy can be prepared for the equipment in order to increase reliability and reduce costs.
What is ABB MACHsense-R? ABB MACHsense-R is a service for monitoring the condition of motors and generators which is provided by ABB Local Service Centers. It is a remote monitoring service using sensors
More informationPrimary Heat Transport (PHT) Motor Rotor Retaining Ring Failure
1 Primary Heat Transport (PHT) Motor Rotor Retaining Ring Failure Ali Malik Components & Equipment Eng. Ontario Power Generation - Darlington Nuclear 2 Ontario Power Generation Darlington Darlington Nuclear
More informationOKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2018 RELIABILITY SCORECARD
OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2018 RELIABILITY SCORECARD June 1, 2018 Table of Contents 1.0 Introduction...3 2.0 Summary...3 3.0 Purpose...3 4.0 Definitions...4 5.0 Analysis...5
More informationProtection for 2500KVA High Tension Transformer Ankita S.Kulkarni 1, Priyanka S.Dhayarkar 2, Harsha H.Ambure 3, Ashwini S.Shinde 4
Protection for 2500KVA High Tension Transformer Ankita S.Kulkarni 1, Priyanka S.Dhayarkar 2, Harsha H.Ambure 3, Ashwini S.Shinde 4 Graduate Student, Dept. of E&TC, Pimpri Chinchwad College of Engineering,
More informationMotors Damage Curves
Motors Damage Curves The information presented in this application guide is for review, approval, interpretation and application by a registered professional engineer only. SKM disclaims any responsibility
More informationDevelopment of a High Efficiency Induction Motor and the Estimation of Energy Conservation Effect
PAPER Development of a High Efficiency Induction Motor and the Estimation of Energy Conservation Effect Minoru KONDO Drive Systems Laboratory, Minoru MIYABE Formerly Drive Systems Laboratory, Vehicle Control
More informationHigh-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd.
Hitachi Review Vol. 53 (2004), No. 3 121 High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd. Hiroaki Yamada Kiyoshi
More informationAdvanced Protective Relay Training
Advanced Protective Relay Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq A properly designed protection
More informationMotor Protection Application Guide
Motor Protection Application Guide About the Authors Paul Lerley has 28 years of utility and electronics experience, including 15 years at Central Maine Power Company. He is a graduate of the University
More informationGenerator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood
Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood Prepared for: SCE&G Fossil/Hydro June 30, 2008 Prepared by: SCE&G Transmission Planning Table of Contents
More informationSmall Generator Interconnection Program Interconnection Technical Requirements
General Program Information What is the purpose of the PGE Small Generator Interconnection Program? How do I initiate a distribution interconnection request for my project? The purpose of our Small Generator
More informationJoslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers
Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers 2 Introduction This discussion describes in detail retrofitting medium voltage circuit
More informationVARIABLE FREQUENCY DRIVES
262923 VARIABLE FREQUENCY DRIVES PART 1: GENERAL 1.01 SUMMARY A. Section Includes: 1. Variable Frequency Drives (VFD) B. Related Sections: 1. Section 230000 - Basic HVAC Requirements 2. Section 230900
More informationTechnical Service Bulletin IOX/DCX Transmitter Maintenance Schedule
Technical Service Bulletin 140610 IOX/DCX Transmitter Maintenance Schedule Service Bulletin 140610 applies to Comark IOX, DCX and Paragon transmitters. This bulletin contains important maintenance schedule
More informationGuidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks
Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks by Georges Barbarin Executive summary Aging electrical switchgear infrastructure is a threat to the reliability of power
More informationM T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed
More informationSENTINEL BATTERY MONITORING
Protecting your power supply SENTINEL BATTERY MONITORING Helios Power Solutions If you re operating mission critical systems and relying on the protection of a UPS and battery bank, then it has to make
More informationREMOTE SENSING DEVICE HIGH EMITTER IDENTIFICATION WITH CONFIRMATORY ROADSIDE INSPECTION
Final Report 2001-06 August 30, 2001 REMOTE SENSING DEVICE HIGH EMITTER IDENTIFICATION WITH CONFIRMATORY ROADSIDE INSPECTION Bureau of Automotive Repair Engineering and Research Branch INTRODUCTION Several
More informationSHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual
Electronic Motor Brake Type G Instructions and Setup Manual Table of Contents Table of Contents Electronic Motor Brake Type G... 1 1. INTRODUCTION... 2 2. DESCRIPTION AND APPLICATIONS... 2 3. SAFETY NOTES...
More informationAppendix 3. DRAFT Policy on Vehicle Activated Signs
Appendix 3 DRAFT Policy on Vehicle Activated Signs Ealing Council has been installing vehicle activated signs for around three years and there are now 45 across the borough. These signs help to reduce
More informationTECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008
NB Power Customer Service and Distribution June 2008 Prepared by: Steven Wilcox Revised by: Steven Wilcox TABLE OF CONTENTS 1.0 Introduction 4 2.0 NB Power Policy on Independent Power Production 4 3.0
More informationLarge Electric Motor Reliability: What Did the Studies Really Say? Howard W Penrose, Ph.D., CMRP President, MotorDoc LLC
Large Electric Motor Reliability: What Did the Studies Really Say? Howard W Penrose, Ph.D., CMRP President, MotorDoc LLC One of the most frequently quoted studies related to electric motor reliability
More informationBenefits of a Cooling Tower VFD Retrofit
Benefits of a Cooling Tower VFD Retrofit Greg Owen Electrical Engineer Ryan Carlson Electrical Engineer 54 th Annual MIPSYCON Conference November 7, 2018 Agenda Project Introduction Project Development
More informationATCO ELECTRIC LTD. (Transmission System) SERVICE QUALITY AND RELIABILITY PERFORMANCE, MEASURES AND INDICES Revision 0
ATCO ELECTRIC LTD. (Transmission System) SERVICE QUALITY AND RELIABILITY PERFORMANCE, MEASURES AND INDICES 2018-04-24 - Revision 0 EUB Decision 2007-071 Board Direction 52 For questions or comments regarding
More informationUpdated Transmission Expansion Plan for the Puget Sound Area to Support Winter South-to-North Transfers
Updated Transmission Expansion Plan for the Puget Sound Area to Support Winter South-to-North Transfers Puget Sound Area Study Team Bonneville Power Administration, Puget Sound Energy, Seattle City Light,
More informationISLANDING SCHEME FOR STATION DURING GRID BLACK-OUT
ISLANDING SCHEME FOR STATION DURING GRID BLACK-OUT By Girija Shankar Sharma, M.Tech (Power System), DGM (O&M-Opn), NTPC-Rihand, E-mail: gssharma@ntpc.co.in Presentation Points System Description and Grid
More informationPower stability for manufacturers
ARTICLE Power stability for manufacturers Manufacturing is a critical aspect of many economies. However, many places lack power grid stability, which leads to production disruption. ABB s PCS100 family
More informationfor Pumping Applications
ENGINEERED SOLUTIONS for MATERIAL HANDLING Secondary Resistance Controllers (SRC) for Pumping Applications 135 Glacier Street Coquitlam, BC V3K 5Z1 Canada Date: September, 2002 Author: Nicole Neuman Synergy
More informationOverview of Helicopter HUMS Research in DSTO Air Vehicles Division
AIAC-12 Twelfth Australian International Aerospace Congress Overview of Helicopter HUMS Research in DSTO Air Vehicles Division Dr Ken Anderson 1 Chief Air Vehicles Division DSTO Australia Abstract: This
More informationGuideline for Parallel Grid Exit Point Connection 28/10/2010
Guideline for Parallel Grid Exit Point Connection 28/10/2010 Guideline for Parallel Grid Exit Point Connection Page 2 of 11 TABLE OF CONTENTS 1 PURPOSE... 3 1.1 Pupose of the document... 3 2 BACKGROUND
More informationA manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard
A manufacturer s view of bushing reliability, testing and analysis By Lars Jonsson Håkan Rudegard 1 A manufacturer s view of bushing reliability, testing and analysis Lars Jonsson Håkan Rudegard ABB Sweden
More informationAdvances in Motor Protection Relay Features
Advances in Motor Protection Relay Features Ricardo Abboud, Paulo Lima, John Needs, and Alejandro Rodriguez Schweitzer Engineering Laboratories, Inc. Dibyendu Bhattacharya BP Exploration Operating Co.,
More informationFigure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E
Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) 41-242.5E 2 Typical 60 Hertz time product curves for the type CWP-1 relay are shown in Figure 4 with 100 volts
More informationProject Summary Fuzzy Logic Control of Electric Motors and Motor Drives: Feasibility Study
EPA United States Air and Energy Engineering Environmental Protection Research Laboratory Agency Research Triangle Park, NC 277 Research and Development EPA/600/SR-95/75 April 996 Project Summary Fuzzy
More informationExceeding the standards with MNS
Exceeding the standards with MNS Exceeding the standards with MNS 5 essentials of switchgear solutions Since ABB first introduced MNS the modular low voltage switchgear platform over forty years ago, MNS
More informationIslanding of 24-bus IEEE Reliability Test System
Islanding of 24-bus IEEE Reliability Test System Paul Trodden February 14, 211 List of Figures 1 24-bus IEEE RTS, with line (3,24) tripped and buses 3,24 and line (3,9) uncertain....................................
More informationABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA
ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA Instruction Leaflet I.L. 41-661.1B Effective: June 1997 Supersedes I.L. 41-661.1A, Dated February 1994 Type
More informationThermo Scientific APEX 500 Rx Metal Detector User s Guide. REC 4345 Rev B Part number English
Thermo Scientific APEX 500 Rx Metal Detector User s Guide REC 4345 Rev B Part number 109541 English 2010 Thermo Fisher Scientific, Inc. All rights reserved For future reference, write your APEX 500 Rx
More informationApplication of Undervoltage Protection to Critical Motors
1 Application of Undervoltage Protection to Critical Motors Matt Proctor, Member, IEEE Abstract Undervoltage protection is commonly used to protect motors from damage during abnormal conditions and to
More informationDouble earth fault in a PSP during back to back launching sequence
Double earth fault in a PSP during back to back launching sequence Jean-Louis DROMMI EDF Hydro Engineering Center, France Pump Storage Scheme, back to back launching Electricité de France Hydro Department
More informationSWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE
SWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE Carlo GEMME Paola BASSI Giorgio MAGNO ABB - Italy ABB - Italy ABB - Italy carlo.gemme@it.abb.com paola.bassi@it.abb.com giorgio.magno@it.abb.com
More informationHigh-Impedance Differential Applications With Mismatched CTs
High-Impedance Differential Applications With Mismatched CTs Russ Franklin, Alliant Energy Hossein Nabi-Bidhendi, ABB Inc. Michael J. Thompson and Héctor J. Altuve, Schweitzer Engineering Laboratories,
More information825-P Modular Protection System for motors Specification Guide
Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection
More informationGovernment of Canada Hopper Car Fleet 2011 Annual Report
Government of Canada Hopper Car Fleet 2011 Annual Report Prairie and Northern Region TP 14995E Her Majesty the Queen in Right of Canada, represented by the Minister of Transport, the Honourable Denis Lebel
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More informationGREENER SHIPPING SUMMIT 2017
GREENER SHIPPING SUMMIT 2017 EU MRV Regulation Methods of Data Collection of Fuel Differences/Consequences/Evaluation of Methods Antonios Georgantzis 14 November 2017 Eugenides Foundation The EU MRV Timeline
More informationRVS-AX Instruction Manual
RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationHydraulic Drive Head Performance Curves For Prediction of Helical Pile Capacity
Hydraulic Drive Head Performance Curves For Prediction of Helical Pile Capacity Don Deardorff, P.E. Senior Application Engineer Abstract Helical piles often rely on the final installation torque for ultimate
More informationGuidelines for connection of generators:
Guidelines for connection of generators: Greater than 30 kva, and not greater than 10 MW, to the Western Power distribution network January, 2017. EDM 32419002 / DM 13529244 Page 1 of 14 Contents 1 INTRODUCTION...
More informationCHAPTER 1 INTRODUCTION
1 CHAPTER 1 INTRODUCTION 1.1 MOTIVATION OF THE RESEARCH Electrical Machinery is more than 100 years old. While new types of machines have emerged recently (for example stepper motor, switched reluctance
More informationArtesis MCM Case Studies. March 2011
Artesis MCM Case Studies March 2011 Case 1 Automotive Company: Automobile Manufacturer A Equipment: Pump Stator Isolation Breakdown Decreasing current unbalance level Case 1 Automotive Company: Automobile
More informationINCREASING electrical network interconnection is
Analysis and Quantification of the Benefits of Interconnected Distribution System Operation Steven M. Blair, Campbell D. Booth, Paul Turner, and Victoria Turnham Abstract In the UK, the Capacity to Customers
More informationDirect On Line (DOL) Motor Starter. Direct Online Motor Starter
Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.
More informationTesting Lead-acid fire panel batteries
Thames House, 29 Thames Street Kingston upon Thames, Surrey, KT1 1PH Phone: +44 (0) 8549 5855 Website: www.fia.uk.com Testing Lead-acid fire panel batteries 1. Background - Methods of testing batteries
More informationOperational Planning Study Report. RTA to BCH transfer limit updates For Kitimat 4 Capacitor Banks
Operational Planning Study Report RTA to BCH transfer limit updates For Kitimat 4 Capacitor Banks Report No. T&S Planning 2013-062 British Columbia Hydro and Power Authority British Columbia Hydro and
More informationSummary of Revision, IEEE C , Guide for Breaker Failure Protection of Power Circuit Breakers
Summary of Revision, IEEE C37.119-2016, Guide for Breaker Failure Protection of Power Circuit Breakers Kevin Donahoe GE Grid Solutions 2018 Texas A&M Protective Relaying Conference Agenda Introduction
More informationABB life cycle services Uninterruptible power supplies
ABB life cycle services Uninterruptible power supplies 2 ABB Life cycle brochure UPS service portfolio Life cycle services for uninterruptible power supplies As your service partner, ABB guarantees you
More informationVariable frequency transformer for asynchronous power transfer
Variable frequency transformer for asynchronous power transfer by Einar Larsen, Richard Piwko and Donald McLaren, GE Energy A new power transmission technology has been developed. The variable frequency
More informationEvolving Bump Chip Carrier
FUJITSU INTEGRATED MICROTECHNOLOGY LIMITED. The Bump Chip Carrier, which was developed as a small pin type, miniature, and lightweight CSP, is not only extremely small due to its characteristic structure,
More informationBattery Maintenance Solutions for Critical Facilities
Battery Maintenance Solutions for Critical Facilities Chapter Two: Meeting Regulatory Requirements and Observing Best Practices Click a section below In chapter one of Emerson Network Power s ebook entitled
More informationCase Study. Modernising gas fired power plant boiler damper drives and damper bearings
Case Study Modernising gas fired power plant boiler damper drives and damper bearings Boiler Damper Drives & Bearings Modernisation Case Study - 10th December 2014 Boiler Damper Drives & Bearings Modernisation
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationIowa State University Electrical and Computer Engineering. E E 452. Electric Machines and Power Electronic Drives
Electrical and Computer Engineering E E 452. Electric Machines and Power Electronic Drives Laboratory #12 Induction Machine Parameter Identification Summary The squirrel-cage induction machine equivalent
More informationCost Affective Dockside Crane Retrofit Utilizing Existing SCR s
Cost Affective Dockside Crane Retrofit Barry W. Wiles Industry Manager Crane Systems Avtron Manufacturing Inc. 7900 E. Pleasant Valley Rd. Independence, OH 44131 Phone: (216) 642-1230 FAX: (216) 642-6037
More information